36" Downdraft

800 Series Downdraft – HDD86051UC

HDD86051UC

Stainless Steel

Sleek, built-in, and retracts out of sight.

Bosch 36" Downdraft’s flexible design seamlessly integrates into your kitchen

Features & Benefits

Beautifully designed to preserve clean sight lines when not in use

Quiet at 1.4 sones* on low speed

Sleek front panel filter design acts as a guard against splatters

6 exhaust connections possible (transition sold separately)

Recirculation kit for sale for use in non ducted applications**

General Properties

Operating mode

Maximum CFM

Sones*

Number of speed settings

Motor location

Damper included

Grease filter material

Grease filter type

Duct direction

Convertible: ducted / recirculating

Blower sold separately

10.3 HS / 1.4 WS

3-stage

External

No

Aluminum

Optional blower required

Multilayer cassette

Front, Left, Right,

Rear, Down

Yes (600 CFM options sold separately)

Technical Details

Volts (V)

Frequency (Hz)

Plug type

120 V

60 Hz

120V-3 prong

Power cord length (in.) 30"

Dimensions & Weight

Overall appliance dimensions (width of canopy included)

(HxWxD) (in.)

29 3 /

8

" x 37" x

2 3 /

4

"

Height of the rise (in.) 12"

Diameter of air duct (in.) internal

8"

Diameter of air duct (in.) external

6" or 8"

Net weight (lbs)

Accessories – Required

Blower (sold separately)

42 lbs

Accessories – Transitions & Blowers

6" side / rear / downward transition

HDDSTRAN6

8" side / rear / downward transition

HDDSTRAN8

NOTE: HDDSTRAN6 or HDDSTRAN8 required for side, rear or downward exhaust applications with inline and remote blowers.

6" round front plate

Transition for rectangular duct

HDDFTRAN6

8" round front plate HDDFTRAN8

NOTE: HDDFTRAN6 or HDDFTRAN8 required for front exhaust applications with inline and remote blowers.

HDDSTRAN2

2' rectangular duct HDD2RECTD

NOTE: HDDSTRAN2 needed to attach HDD2RECTD to downdraft. For use with installation of inline or remote blower applications.

600 CFM flexible blower DHG602DUC

600 CFM inline blower DHG6015NUC

600 CFM remote blower DHG6023RUC

Accessories – Optional

Recirculation kit

(compatible with electric, induction and FlameSelect Gas

Cooktops)

HDDREC5UC

HDDFILTUC Charcoal filter replacement for recirculation kit

36" Gas Cooktop Seal

Kit for Downdraft

(required for installation with gas cooktops)

Trim Kit for 36"

FlameSelect® Gas

Cooktops

HDD6RSP

HDDTRIM36S

*Sound test performed as per HVI standards at independent lab.

* *Recirculation kit is not compatible with gas cooktop installations with downdraft

Accessories: To purchase Bosch accessories, cleaners & parts please visit www.bosch-home.com/us/store or call 1-800-944-2904 (Mon to Fri 5 am to 6 pm PST, Sat 6 am to 3 pm PST).

Notes: All height, width and depth dimensions are shown in inches. BSH reserves the absolute and unrestricted right to change product materials and specifications, at any time, without notice. Consult the product’s installation instructions for final dimensional data and other details prior to making cutout.

Warranties: Please see Use & Care manual or Bosch website for statement of limited warranty.

For more information on our entire line of products, go to www.bosch-home.com/us or call 1-800-944-2904

© BSH Home Appliances Corporation. All rights reserved. Bosch is a registered trademark of Robert Bosch GmbH.

11/19

36" Downdraft

800 Series Downdraft – HDD86051UC

Installation Details

PRODUCT

CLEARANCES

Downdraft electrical cable is 30" long

Accessories: To purchase Bosch accessories, cleaners & parts please visit www.bosch-home.com/us/store or call 1-800-944-2904 (Mon to Fri 5 am to 6 pm PST, Sat 6 am to 3 pm PST).

Notes: All height, width and depth dimensions are shown in inches. BSH reserves the absolute and unrestricted right to change product materials and specifications, at any time, without notice. Consult the product’s installation instructions for final dimensional data and other details prior to making cutout.

Warranties: Please see Use & Care manual or Bosch website for statement of limited warranty.

For more information on our entire line of products, go to www.bosch-home.com/us or call 1-800-944-2904

© BSH Home Appliances Corporation. All rights reserved. Bosch is a registered trademark of Robert Bosch GmbH.

11/19

36" Downdraft

800 Series Downdraft – HDD86051UC

Installation Details – Cutouts

GAS

Template

2-1/8" (54)

Downdraft cutout width:

30" (762) is 27-1/16" (687)

36" (914) is 33-1/16" (840)

1-1/16"

(27)

BT

24-11/16" (628)

22-5/16" (567)

19-1/8" (486)

MIN.

1/2"

(13)

Cooktop cutout width

1-7/8" (48)

ELECTRIC AND INDUCTION

Downdraft cutout width:

30" (762) is 27-1/16" (687)

36" (914) is 33-1/16" (840)

Template

2-1/8" (54)

25-7/16" - 25-9/16"

(646 - 649)

22-11/16" - 22-13/16"

(576 - 579)

19-7/8" - 20"

(505 - 508)

11/16"

(17)

BT

MIN.

1/2"

(13)

Cooktop cutout width

2-1/4" (57)

Accessories: To purchase Bosch accessories, cleaners & parts please visit www.bosch-home.com/us/store or call 1-800-944-2904 (Mon to Fri 5 am to 6 pm PST, Sat 6 am to 3 pm PST).

Notes: All height, width and depth dimensions are shown in inches. BSH reserves the absolute and unrestricted right to change product materials and specifications, at any time, without notice. Consult the product’s installation instructions for final dimensional data and other details prior to making cutout.

Warranties: Please see Use & Care manual or Bosch website for statement of limited warranty.

For more information on our entire line of products, go to www.bosch-home.com/us or call 1-800-944-2904

© BSH Home Appliances Corporation. All rights reserved. Bosch is a registered trademark of Robert Bosch GmbH.

11/19

36" Downdraft

800 Series Downdraft – HDD86051UC

Accessories – Transitions

SIDE / REAR / DOWNWARD TRANSITION FOR DOWNDRAFT

6" Round transition enable ducting to be at sides, rear or below downdraft for flexible configurations to maximize your kitchen design

HDDSTRAN6

6" Side / Rear /

Downward Transition for Downdraft

Flexible transition design allows for left, right, rear or downward venting

Front rough-in plate may be used with a

6" round duct or elbow

Ability to use with DHG6015NUC inline or

DHG6023RUC remote blowers

Some blower positions may need deeper cabinets. See installation guide.

ROUND FRONT PLATES FOR DOWNDRAFT

6" Front rough-in plate enable ducting to be at front of downdraft, for use with inline and remote blower applications

HDDFTRAN6

6" Round Front

Plate for Downdraft

Front rough-in plate design allows for front venting

Front rough-in plate may be used with a 6" round duct or elbow

Ability to use with DHG6015NUC inline or

DHG6023RUC remote blowers

HDDSTRAN8

8" Side / Rear /

Downward Transition for Downdraft

8" Round transition enable ducting to be at sides, rear or below downdraft for flexible configurations to maximize your kitchen design

Flexible transition design allows for left, right, rear or downward venting

For DHG602DUC flexible downdraft blower used as inline installation

Some blower positions may need deeper cabinets. See installation guide.

HDDFTRAN8

8" Round Front

Plate for Downdraft

8" Front rough-in plate enable ducting to be at front of downdraft, for use with inline and remote blower applications

Front rough-in plate design allows for front venting

Front rough-in plate may be used with a 8" round duct or elbow

For DHG602DUC flexible downdraft blower used as inline installation

NOTE: HDDSTRAN6 or HDDSTRAN8 side / rear / downward transition required for side, rear or downward exhaust applications with inline and remote blowers.

NOTE: HDDFTRAN6 or HDDFTRAN8 front plate required for front exhaust applications with inline and remote blowers.

Accessories: To purchase Bosch accessories, cleaners & parts please visit www.bosch-home.com/us/store or call 1-800-944-2904 (Mon to Fri 5 am to 6 pm PST, Sat 6 am to 3 pm PST).

Notes: All height, width and depth dimensions are shown in inches. BSH reserves the absolute and unrestricted right to change product materials and specifications, at any time, without notice. Consult the product’s installation instructions for final dimensional data and other details prior to making cutout.

Warranties: Please see Use & Care manual or Bosch website for statement of limited warranty.

For more information on our entire line of products, go to www.bosch-home.com/us or call 1-800-944-2904

© BSH Home Appliances Corporation. All rights reserved. Bosch is a registered trademark of Robert Bosch GmbH.

11/19

36" Downdraft

800 Series Downdraft – HDD86051UC

Accessories – Transitions

TRANSITION FOR RECTANGULAR DUCT FOR DOWNDRAFT

Rectangular duct transition required to connect 2' rectangular duct to downdraft

HDDSTRAN2

Transition for

Rectangular Duct for Downdraft

2' RECTANGULAR DUCT FOR DOWNDRAFT

2' Rectangular duct can be used as extension to exhaust through a cabinet or wall while maximizing cabinet storage space

HDD2RECTD

2' Rectangular

Duct Downdraft

Duct can be used as an extension to exhaust through a cabinet or wall

May be attached to sides or rear of downdraft housing

HDDRECTRN transition needed to connect

HDD2RECTD to downdraft housing

For use with remote or inline blowers

Accessories: To purchase Bosch accessories, cleaners & parts please visit www.bosch-home.com/us/store or call 1-800-944-2904 (Mon to Fri 5 am to 6 pm PST, Sat 6 am to 3 pm PST).

Notes: All height, width and depth dimensions are shown in inches. BSH reserves the absolute and unrestricted right to change product materials and specifications, at any time, without notice. Consult the product’s installation instructions for final dimensional data and other details prior to making cutout.

Warranties: Please see Use & Care manual or Bosch website for statement of limited warranty.

For more information on our entire line of products, go to www.bosch-home.com/us or call 1-800-944-2904

© BSH Home Appliances Corporation. All rights reserved. Bosch is a registered trademark of Robert Bosch GmbH.

11/19

36" Downdraft

800 Series Downdraft – HDD86051UC

Accessories – 600 CFM Blowers

DHG6015NUC

600 CFM Inline

Blower

600 CFM inline blower

For use with Bosch downdrafts

Inline blowers can be mounted remotely to minimize blower noise in the cooking area

Designed to be mounted inline with the ducting installation

Blower is mounted on roof of exterior wall depending on application needs

6" transition required

DHG602DUC

600 CFM Flexible

Integral Blower –

HDD Downdrafts

600 CFM flexible blower can mount to downdraft or be used as an inline blower, and can be rotated to exhaust downward or to sides

Capable up to 600 CFM in performance

Blower is able to mount to downdraft or be used as an inline blower

Blower can be rotated to exhaust downward or toward sides

Additional accessories may be required for installation, see manual

DHG6023RUC

600 CFM

Remote Blower

600 CFM remote blower

For use with Bosch downdrafts

Can be mounted on the exterior of the home to minimize noise in the cooking area

Blower is mounted on roof of exterior wall depending on application needs

6" transition required

Accessories: To purchase Bosch accessories, cleaners & parts please visit www.bosch-home.com/us/store or call 1-800-944-2904 (Mon to Fri 5 am to 6 pm PST, Sat 6 am to 3 pm PST).

Notes: All height, width and depth dimensions are shown in inches. BSH reserves the absolute and unrestricted right to change product materials and specifications, at any time, without notice. Consult the product’s installation instructions for final dimensional data and other details prior to making cutout.

Warranties: Please see Use & Care manual or Bosch website for statement of limited warranty.

For more information on our entire line of products, go to www.bosch-home.com/us or call 1-800-944-2904

© BSH Home Appliances Corporation. All rights reserved. Bosch is a registered trademark of Robert Bosch GmbH.

11/19

36" Downdraft

800 Series Downdraft – HDD86051UC

Accessories – Optional

HDDREC5UC

Recirculation Kit for Downdraft

When ducting to the exterior is not feasible, downdraft recirculation kit allows filtered air to reenter the kitchen while cooking

When ducting is not feasible, kit eliminates need to exhaust outside

Air is filtered through charcoal filter, then re-enters kitchen

Includes recirculation module, filter and metal grille vent plate

Designed to work with both 30" and 36" bosch downdrafts, HDD series

Use with induction / electric cooktops only

HDDFILTUC

Charcoal Filter

Replacement for

Recirculation Kit for Downdraft

Maintain performance of Bosch downdraft recirculation kit with timely replacement of charcoal filter to capture and filter odors

Replacement charcoal filter for HDDREC5UC recirculation kit

Quality charcoal filter effectively captures and filters odors

Replace charcoal filter every 6 months depending on usage

HDDTRIM36S

Trim Kit for 36"

FlameSelect® Gas

Cooktops

36" trim kit for installation with 36" FlameSelect® gas cooktops

Includes trim kit and installation tool

Required for installation with 36" FlameSelect® gas cooktops

HDD6RSP

36" Gas Cooktop

Seal Kit for Downdraft

36" gas cooktop seal kit required for installation with 36" gas cooktops

Includes trim, seal, metal grill, and fasteners

Required for installation with gas cooktops

Accessories: To purchase Bosch accessories, cleaners & parts please visit www.bosch-home.com/us/store or call 1-800-944-2904 (Mon to Fri 5 am to 6 pm PST, Sat 6 am to 3 pm PST).

Notes: All height, width and depth dimensions are shown in inches. BSH reserves the absolute and unrestricted right to change product materials and specifications, at any time, without notice. Consult the product’s installation instructions for final dimensional data and other details prior to making cutout.

Warranties: Please see Use & Care manual or Bosch website for statement of limited warranty.

For more information on our entire line of products, go to www.bosch-home.com/us or call 1-800-944-2904

© BSH Home Appliances Corporation. All rights reserved. Bosch is a registered trademark of Robert Bosch GmbH.

11/19

36" Downdraft

800 Series Downdraft – HDD86051UC

Flexible Blower Installation – Front Exhaust Example

Application

• Flexible blower attached can rotate for left, right or downward discharge

• Front downward application with flexible blower

• Requires space under floor line for ductwork*

• Can be used with optional Recirculation Kit, sold separately

• Elbow, ductwork, blower support structure frame not included

Required Blower

DHG602DUC

600 CFM Flexible Integral

Blower

600 CFM flexible blower can mount to downdraft or be used as an inline blower, and can be rotated to exhaust downward or to sides

Optional Accessories

HDDREC5UC

Recirculation Kit for Downdraft

When ducting to the exterior is not feasible, downdraft recirculation kit allows filtered air to reenter the kitchen while cooking

HDDFILTUC

Charcoal Filter Replacement for Recirculation Kit for Downdraft

Maintain performance of Bosch downdraft recirculation kit with timely replacement of charcoal filter to capture and filter odors

HDD6RSP

36" Gas Cooktop Seal Kit for Downdraft

36" gas cooktop seal kit required for installation with 36" gas cooktops

* For only front downward ducting applications, electrical panel must be remotely mounted. Electrical panel can still be remotely mounted in other exhaust configurations if desired. Electrical panel interconnect cable length is 5-ft. long.

Accessories: To purchase Bosch accessories, cleaners & parts please visit www.bosch-home.com/us/store or call 1-800-944-2904 (Mon to Fri 5 am to 6 pm PST, Sat 6 am to 3 pm PST).

Notes: All height, width and depth dimensions are shown in inches. BSH reserves the absolute and unrestricted right to change product materials and specifications, at any time, without notice. Consult the product’s installation instructions for final dimensional data and other details prior to making cutout.

Warranties: Please see Use & Care manual or Bosch website for statement of limited warranty.

For more information on our entire line of products, go to www.bosch-home.com/us or call 1-800-944-2904

© BSH Home Appliances Corporation. All rights reserved. Bosch is a registered trademark of Robert Bosch GmbH.

11/19

36" Downdraft

800 Series Downdraft – HDD86051UC

Flexible Blower Installation – Front Exhaust with Flexible Blower Used as an

Inline Option Example

Application

• Side exhaust with flexible blower used as inline option if ducting is more convenient with this configuration

• Requires at least 18" of clearance to fit the blower and transition

• Blower must be accessible for maintenance

• Elbow, ductwork, blower support structure frame not included

Required Blower

DHG602DUC

600 CFM Flexible Integral

Blower

600 CFM flexible blower can mount to downdraft or be used as an inline blower, and can be rotated to exhaust downward or to sides

Required Accessories

HDDFTRAN8

8" Round Front Plate for

Downdraft

8" Front rough-in plate enable ducting to be at front of downdraft, for use with inline and remote blower applications

NOTE: HDDFTRAN8 front plate required for front exhaust applications with inline and remote blowers.

Optional Accessories

HDD6RSP

36" Gas Cooktop Seal Kit for Downdraft

36" gas cooktop seal kit required for installation with 36" gas cooktops

NOTE: Some applications may require deeper cabinets. Side and rear exhaust require at least 18" of clearance to fit the blower and / or ductwork. Refer to installation instructions.

Accessories: To purchase Bosch accessories, cleaners & parts please visit www.bosch-home.com/us/store or call 1-800-944-2904 (Mon to Fri 5 am to 6 pm PST, Sat 6 am to 3 pm PST).

Notes: All height, width and depth dimensions are shown in inches. BSH reserves the absolute and unrestricted right to change product materials and specifications, at any time, without notice. Consult the product’s installation instructions for final dimensional data and other details prior to making cutout.

Warranties: Please see Use & Care manual or Bosch website for statement of limited warranty.

For more information on our entire line of products, go to www.bosch-home.com/us or call 1-800-944-2904

© BSH Home Appliances Corporation. All rights reserved. Bosch is a registered trademark of Robert Bosch GmbH.

11/19

36" Downdraft

800 Series Downdraft – HDD86051UC

Flexible Blower Installation – Side Exhaust Example

Application

• Side exhaust option if ducting is more convenient with this configuration

• Requires at least 18" of clearance to fit the blower and transition

• Can be used with optional Recirculation Kit, sold separately

• Elbow, ductwork, blower support structure frame not included

Required Blower

Left Side Exhaust

DHG602DUC

600 CFM Flexible Integral

Blower

600 CFM flexible blower can mount to downdraft or be used as an inline blower, and can be rotated to exhaust downward or to sides

Optional Accessories

HDDREC5UC

Recirculation Kit for Downdraft

When ducting to the exterior is not feasible, downdraft recirculation kit allows filtered air to reenter the kitchen while cooking

Right Side Exhaust

Required Accessories

HDDSTRAN8

8" Side / Rear / Downward

Transition for Downdraft

8" Round transition enable ducting to be at sides, rear or below downdraft for flexible configurations to maximize your kitchen design

NOTE: HDDSTRAN8 side / rear / downward transition required for side, rear or downward exhaust applications with inline and remote blowers.

HDDFILTUC

Charcoal Filter Replacement for Recirculation

Kit for Downdraft

Maintain performance of Bosch downdraft recirculation kit with timely replacement of charcoal filter to capture and filter odors

HDD6RSP

36" Gas Cooktop Seal Kit for Downdraft

36" gas cooktop seal kit required for installation with 36" gas cooktops

NOTE: Some applications may require deeper cabinets. Side and rear exhaust require at least 18" of clearance to fit the blower and / or ductwork. Refer to installation instructions.

Accessories: To purchase Bosch accessories, cleaners & parts please visit www.bosch-home.com/us/store or call 1-800-944-2904 (Mon to Fri 5 am to 6 pm PST, Sat 6 am to 3 pm PST).

Notes: All height, width and depth dimensions are shown in inches. BSH reserves the absolute and unrestricted right to change product materials and specifications, at any time, without notice. Consult the product’s installation instructions for final dimensional data and other details prior to making cutout.

Warranties: Please see Use & Care manual or Bosch website for statement of limited warranty.

For more information on our entire line of products, go to www.bosch-home.com/us or call 1-800-944-2904

© BSH Home Appliances Corporation. All rights reserved. Bosch is a registered trademark of Robert Bosch GmbH.

11/19

36" Downdraft

800 Series Downdraft – HDD86051UC

Flexible Blower Installation – Side Exhaust with Slim 2' Rectangular Duct Example

Application

• Side exhaust option if ducting is more convenient with this configuration

• A slim 2' rectangular duct is available to place flexible blower in areas such as unused corner in island or peninsula applications

• Can be used with optional Recirculation Kit, sold separately

• Elbow, ductwork, blower support structure frame not included

Required Blower

Required Accessories

HDD2RECTD

2' Rectangular

Duct Downdraft

2' Rectangular duct can be used as extension to exhaust through a cabinet or wall while maximizing cabinet storage space

DHG602DUC

600 CFM Flexible Integral

Blower

600 CFM flexible blower can mount to downdraft or be used as an inline blower, and can be rotated to exhaust downward or to sides

HDDSTRAN2

Transition for Rectangular

Duct for Downdraft

Rectangular duct transition required to connect 2' rectangular duct to downdraft

Optional Accessories

HDDREC5UC

Recirculation Kit for Downdraft

When ducting to the exterior is not feasible, downdraft recirculation kit allows filtered air to reenter the kitchen while cooking

HDDSTRAN8

8" Side / Rear / Downward

Transition for Downdraft

8" Round transition enable ducting to be at sides, rear or below downdraft for flexible configurations to maximize your kitchen design

NOTE: HDDSTRAN8 side / rear / downward transition required for side, rear or downward exhaust applications with inline and remote blowers.

HDDFILTUC

Charcoal Filter Replacement for Recirculation

Kit for Downdraft

Maintain performance of Bosch downdraft recirculation kit with timely replacement of charcoal filter to capture and filter odors

HDD6RSP

36" Gas Cooktop Seal Kit for Downdraft

36" gas cooktop seal kit required for installation with 36" gas cooktops

NOTE: Some applications may require deeper cabinets. Side and rear exhaust require at least 18" of clearance to fit the blower and / or ductwork. Refer to installation instructions.

Accessories: To purchase Bosch accessories, cleaners & parts please visit www.bosch-home.com/us/store or call 1-800-944-2904 (Mon to Fri 5 am to 6 pm PST, Sat 6 am to 3 pm PST).

Notes: All height, width and depth dimensions are shown in inches. BSH reserves the absolute and unrestricted right to change product materials and specifications, at any time, without notice. Consult the product’s installation instructions for final dimensional data and other details prior to making cutout.

Warranties: Please see Use & Care manual or Bosch website for statement of limited warranty.

For more information on our entire line of products, go to www.bosch-home.com/us or call 1-800-944-2904

© BSH Home Appliances Corporation. All rights reserved. Bosch is a registered trademark of Robert Bosch GmbH.

11/19

36" Downdraft

800 Series Downdraft – HDD86051UC

Flexible Blower Installation – Rear Exhaust Example

Application

• Rear exhaust option is possible if ducting is more convenient with this configuration

• Requires at least 18" of clearance to fit the blower and transition

• Blower must be accessible for maintenance

• Can be used with optional Recirculation Kit, sold separately

• Elbow, ductwork, blower support structure frame not included

Required Blower

DHG602DUC

600 CFM Flexible Integral

Blower

600 CFM flexible blower can mount to downdraft or be used as an inline blower, and can be rotated to exhaust downward or to sides

Required Accessories

HDDSTRAN8

8" Side / Rear / Downward

Transition for Downdraft

8" Round transition enable ducting to be at sides, rear or below downdraft for flexible configurations to maximize your kitchen design

NOTE: HDDSTRAN8 side / rear / downward transition required for side, rear or downward exhaust applications with inline and remote blowers.

Optional Accessories

HDDREC5UC

Recirculation Kit for Downdraft

When ducting to the exterior is not feasible, downdraft recirculation kit allows filtered air to reenter the kitchen while cooking

HDDFILTUC

Charcoal Filter Replacement for Recirculation

Kit for Downdraft

Maintain performance of Bosch downdraft recirculation kit with timely replacement of charcoal filter to capture and filter odors

HDD6RSP

36" Gas Cooktop Seal Kit for Downdraft

36" gas cooktop seal kit required for installation with 36" gas cooktops

NOTE: Some applications may require deeper cabinets. Side and rear exhaust require at least 18" of clearance to fit the blower and / or ductwork. Refer to installation instructions.

Accessories: To purchase Bosch accessories, cleaners & parts please visit www.bosch-home.com/us/store or call 1-800-944-2904 (Mon to Fri 5 am to 6 pm PST, Sat 6 am to 3 pm PST).

Notes: All height, width and depth dimensions are shown in inches. BSH reserves the absolute and unrestricted right to change product materials and specifications, at any time, without notice. Consult the product’s installation instructions for final dimensional data and other details prior to making cutout.

Warranties: Please see Use & Care manual or Bosch website for statement of limited warranty.

For more information on our entire line of products, go to www.bosch-home.com/us or call 1-800-944-2904

© BSH Home Appliances Corporation. All rights reserved. Bosch is a registered trademark of Robert Bosch GmbH.

11/19

36" Downdraft

800 Series Downdraft – HDD86051UC

Flexible Blower Installation – Downward Exhaust Example

Application

• Downward exhaust option if ducting is more convenient with this configuration

• Requires at least 18" of clearance to fit the blower and transition

• Can be used with optional Recirculation Kit, sold separately

• Elbow, ductwork, blower support structure frame not included

• Blower must be accessible for maintenance

• Can also be installed with inline and remote blowers

Required Blower

Required Accessories

HDDSTRAN8

8" Side / Rear / Downward

Transition for Downdraft

8" Round transition enable ducting to be at sides, rear or below downdraft for flexible configurations to maximize your kitchen design

NOTE: HDDSTRAN8 side / rear / downward transition required for side, rear or downward exhaust applications with inline and remote blowers.

Optional Accessories

HDDREC5UC

Recirculation Kit for Downdraft

When ducting to the exterior is not feasible, downdraft recirculation kit allows filtered air to reenter the kitchen while cooking

DHG602DUC

600 CFM Flexible Integral

Blower

600 CFM flexible blower can mount to downdraft or be used as an inline blower, and can be rotated to exhaust downward or to sides

HDDFILTUC

Charcoal Filter Replacement for Recirculation

Kit for Downdraft

Maintain performance of Bosch downdraft recirculation kit with timely replacement of charcoal filter to capture and filter odors

HDD6RSP

36" Gas Cooktop Seal Kit for Downdraft

36" gas cooktop seal kit required for installation with 36" gas cooktops

Accessories: To purchase Bosch accessories, cleaners & parts please visit www.bosch-home.com/us/store or call 1-800-944-2904 (Mon to Fri 5 am to 6 pm PST, Sat 6 am to 3 pm PST).

Notes: All height, width and depth dimensions are shown in inches. BSH reserves the absolute and unrestricted right to change product materials and specifications, at any time, without notice. Consult the product’s installation instructions for final dimensional data and other details prior to making cutout.

Warranties: Please see Use & Care manual or Bosch website for statement of limited warranty.

For more information on our entire line of products, go to www.bosch-home.com/us or call 1-800-944-2904

© BSH Home Appliances Corporation. All rights reserved. Bosch is a registered trademark of Robert Bosch GmbH.

11/19

36" Downdraft

800 Series Downdraft – HDD86051UC

Flexible Blower Installation – Recirculation Example

Application

• Allows for non-ducted downdraft installation by eliminating the need to exhaust to the exterior of the home

• Mount to toe kick or base of a cabinet and attach directly to flexible blower

• Recirculation module and metal grill vent plate placement can be rotated for flexible exhaust placement

• Elbow, ductwork, blower support structure frame not included

Required Blower

Required Accessories

HDDREC5UC

Recirculation Kit for Downdraft

When ducting to the exterior is not feasible, downdraft recirculation kit allows filtered air to reenter the kitchen while cooking

DHG602DUC

600 CFM Flexible Integral

Blower

600 CFM flexible blower can mount to downdraft or be used as an inline blower, and can be rotated to exhaust downward or to sides

Optional Accessories

HDDFILTUC

Charcoal Filter Replacement for Recirculation

Kit for Downdraft

Maintain performance of Bosch downdraft recirculation kit with timely replacement of charcoal filter to capture and filter odors

INSTALL THE

RECIRCULATION BOX

1. Cut opening in cabinet base.

1. Cut opening in cabinet base.

14 1/2”

(368)

• Size: 14 1/2” (368) x 15” (380)

• Orientation depends upon direction of exhaust.

• Double-check that blower outlet and recirculation box inlet will align.

• Double-check that blower outlet and recirculation box inlet will align.

2. Temporarily place recirculation box into opening in cabinet base.

15”

(380)

3. Remove recirculation box from opening.

3. Remove recirculation box from opening.

4. Cut exhaust opening.

• Size: 3 1/2” (89) x 14 1/4” (362)

4. Cut exhaust opening.

• Size: 3 1/2” (89) x 14 1/4” (362)

• This opening will be covered with decorative grille.

3 1/2" (89) x 14 1/4" (362)

EXHAUST OPENING location.

location.

• Seal the duct connection(s) with aluminum tape to make them secure and

Measurements in inches (mm).

• Seal the duct connection(s) with aluminum tape to make them secure and air tight. Do not use duct tape.

air tight. Do not use duct tape.

EXHAUST

THROUGH

CABINET

SIDE

14 1/2”

(368)

DECORATIVE

GRILLE

15”

(380)

3 1/2" (89) x 14 1/4" (362)

EXHAUST OPENING

EXHAUST

THROUGH

CABINET

BACK

Measurements

14 1/2"

(368)

EXHAUST

THROUGH

CABINET

SIDE

EXHAUST

THROUGH

CABINET

BACK

14 1/2"

(368)

DECORATIVE

GRILLE

HDD6RSP

36" Gas Cooktop Seal Kit for Downdraft

36" gas cooktop seal kit required for installation with 36" gas cooktops

6. Install blower.

• See blower instructions.

6. Install blower.

• See blower instructions.

• Use 8” (203) round duct to connect blower exhaust to recirculation box inlet inlet

• Seal the duct connections with aluminum tape to make them secure and air tight. Do not use duct tape.

air tight. Do not use duct tape.

DECORATIVE

GRILLE

3 1/2" (89) x 14 1/4" (362)

EXHAUST OPENING

DECORATIVE

GRILLE

15"

(380)

3 1/2" (89) x 14 1/4" (362)

EXHAUST OPENING

15"

(380)

8.

• Drill 1/8” (3) pilot holes through top of recirculation box and attach legs to recirculation box with 4 - #8 x .375” screws.

7. Install decorative grille.

• Use screws provided.

Blower mounted to downdraft using

7. Install decorative grille.

• Use screws provided.

• framing in remote location - using mounting brackets.

Blower outlet and recirculation box inlet must align.

(See below.)

Blower mounted to downdraft using

BLOWER

Blower mounted to framing in remote location - using mounting brackets.

inlet must align.

METAL 8” ROUND DUCT

(per local codes)

(203) in inches (mm).

DIMENSIONS

(406)

17 1/2”

Notes: All height, width and depth dimensions are shown in inches. BSH reserves the absolute and unrestricted right to change product materials and specifications, at any time, without

Blower outlet and

(See below.)

6 1/2”

(165)

8” notice. Consult the product’s installation instructions for final dimensional data and other details prior to making cutout.

Measurements

(311)

16”

16”

(406)

16”

(406)

DIMENSIONS

11/19 mounting legs.

(per local codes)

Accessories: To purchase Bosch accessories, cleaners & parts please visit www.bosch-home.com/us/store or call 1-800-944-2904 (Mon to Fri 5 am to 6 pm PST, Sat 6 am to 3 pm PST).

(445)

Warranties: Please see Use & Care manual or Bosch website for statement of limited warranty.

For more information on our entire line of products, go to www.bosch-home.com/us or call 1-800-944-2904

© BSH Home Appliances Corporation. All rights reserved. Bosch is a registered trademark of Robert Bosch GmbH.

14”

(356)

3 1/4”

(83)

Measurements in inches (mm).

15”

(380)

(95)

12 1/4”

(311)

(356)

15”

(380)

16”

(406)

3 3/4”

(95)

BLOWER

BLOWER ALIGN BLOWER

ALIGN BLOWER

OUTLET WITH

OUTLET WITH

MOUNTING

LEGS

RECIRCULATION

MOUNTING

BOX INLET

LEGS

BOX INLET

EXHAUST THROUGH EXHAUST THROUGH EXHAUST THROUGH

CABINET BACK

EXHAUST THROUGH

CABINET FRONT (TOE KICK)

FILTER REPLACEMENT

6 months. However, this may vary, depending upon the type and

CUSTOM-MADE

CUSTOM-MADE

DECORATIVE GRILLE

amount of cooking you do. Call customer service or your local this kit as a template for the overall size and mounting hole locations.

The grille opening pattern is up to you.

2 min.

2 min.

Page 5

Page 5

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement