GENEQ CC4648-000 Vaccine Fridge Thermometer Temperature Monitoring System Instruction manual
Geneq CC4648-000 is a versatile thermometer with a triple display for current, minimum, and maximum temperatures, making it ideal for monitoring indoor and outdoor conditions. Its programmable low and high alarm limits, with audible alerts, help you stay informed of any extreme temperature fluctuations. It also features a °C/°F exchange option, a low battery indicator, a foldaway stand, and a mounting keyhole for convenient placement.
Advertisement
Advertisement
INSTRUCTION MANUAL FOR THERMOMETER MODEL CC4648-000
FEATURES
• Triple display for current, minimum and maximum temperature
• Programmable low and high alarm limit
• Outdoor temperature display
• °C / °F exchange
• Low battery indication
• Foldaway stand
• Mounting keyhole
SPECIFICATIONS
Measuring range
- 50 ~ 70°C / -58 ~ 158°F - external probe (bottle)
Display accuracy
-20 ~ 50 ± 0.3°C
Display resolution 0.1°
Display reading update
Battery
Accessories
10 seconds
1.5 volt, type AAA x2 pieces
1) Outdoor sensor with 3 meters long and glycol bottle
2) Battery 1.5 volt x2 pieces
INSTALLATION
1. Plug outdoor sensor into unit.
2. Install battery with correct polarity positioning.
3. The unit will perform a self-test and then display readings normally after 3 seconds.
4. Press (°C/°F) to select temperature unit.
5. Place unit at the place away from direct sunlight, rain or extreme heat.
6. Click on OUT to display the refrigerator temperature.
OPERATION
LOW AND HIGH ALARM LIMIT SETTING
1. Press (MODE) to enable alarm setting.
2. Press (LO ) to set low alarm limit**.
3. Press (HI ) to set high alarm limit**.
4. Press (MODE) to return to normal display.
5. When the current reading is lower or higher than the alarm limit the alarm will sound.
6. To stop the alarm sound press any button once. The LO or HI icon will still be flashing until the current reading is within the alarm limit.
7. Press ( ) to disable or enable the alarm function.
** Holding down the button will increase the value automatically.**
RESET MINIMUM (MIN) and MAXIMUM (MAX) READING MEMORY
1. In MIN-MAX display mode, press (MIN-RESET) to reset minimum reading memory to current reading.
2. Press (MAX-RESET) to reset maximum reading memory to current reading.
3. Reset the memory once before taking new minimum or maximum reading.
IN / OUTDOOR TEMPERATURE DISPLAY
Press (IN-OUT) to select outdoor or indoor temperature display.
NOTE:
1. When the low battery symbol( )appears, replace the battery with a same type new battery.
2. If the thermometer is not in use for a long period of time then remove the battery from battery compartment to avoid battery leakage.
3. If there is abnormal operation or display then press (RESET ) once .
Advertisement