STOP!
PLEASE READ THE FOLLOWING INFORMATION.
INSTALLER
DFWM-12-FR & DFWM-19-FR Fountains are among the easiest to install
Fountains on the market today. To assure you install these models easily and correctly, PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING
THE INSTALLATION. CHECK YOUR INSTALLATION FOR COMPLIANCE WITH
PLUMBING, ELECTRICAL, AND OTHER APPLICABLE CODES.
After installation, leave these instructions with the Fountain for future reference.
This Freeze Resistant Fountain is shipped in two separate cartons. The second carton contains the Freeze Resistant Package that is installed on an interior heated wall. Refer to the Freeze Resistant Package for the rough-in dimensions for installation.
IMPORTANT
ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON
IMPORTANT
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO
WATER LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY
OCCUR AWAY FROM THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO
A FOUNTAIN, CREATING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE
IN THE METAL CONTENT OF THE WATER. THIS CONDITION IS AVOIDABLE BY USING THE PROPER
MATERIALS AS INDICATED. ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE
OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING PLUMBING SYSTEM.
2302 Yellow Smoke Road
PO Box 369
Denison, IA 51442
800.325.2380
www.bohlmann.com
IMPORTANT! INSTALLER PLEASE NOTE
Wall mounting structure must be capable of supporting 300 lb. load on fountain.
GENERAL INSTALL TIPS
1
2
3
4
5
6
7
8
This fountain is to be mounted on a smooth, flat, finished wall surface with adequate support structure.
Wall should already be framed for the fountain using dimensions shown in rough-in’s below. Shown dimensions pertain to installation location.
Remove bottom cover from fountain and save the screws. Assemble the push rod to the fountain. (Push rod provided with freeze resistant box)
Install the fountain using bolts and washers (not provided). Tighten securely.
Attach drain tube to fountain and cut to required length using the freeze resistant box as a guide.
Install freeze resistant box - see box instructions.
Install a service stop (not provided) and make water supply connection from the stop to the strainer in the freeze resistant box.
DO NOT SOLDER TUBES INSERTED
INTO THE STRAINER AS DAMAGE TO
THE O-RINGS MAY RESULT.
Connect fountain water line to freeze resistant box - see box instructions.
Replace the bottom cover.
19 ”
482 mm
15 1/4”
387 mm
35 1/2”
902 mm
34”
864 mm
27”
686 mm
DFWM-19-FR
FIGURE 1
SUGGESTED CONFIGURATION
FOR EXPOSED MOUNTING BOLTS
ACORN NUT
WASHER
CLOSET SCREW
OR THREADED ROD
(DEPENDING ON WALL TYPE
AND ANCHOR USED)
DFWM-12-FR
12 7/8”
327 mm
FIGURE 2
7 1/4”
184 mm
NOTE
DFWM-12-FR height is the same as
DFWM-19-FR
FREEZE
RESISTANT
BOX
7/16”
11 mm
MOUNTING
HOLE (3)
1 3/4”
44 mm
WASTE LINE
3”
76 mm
29 7/16”
748 mm
12 7/8”
327 mm
3”
76 mm
2”
51 mm
3 7/8”
98 mm
1”
25 mm
FOR PUSHROD
5 3/16”
132 mm
7/16”
12 mm
7/8”
22 mm
O.D.
WATER
INLET
(3) 29 1/8”
740 mm
13 7/16”
342 mm
FINISHED FLOOR
2 DFWM-12-FR & DFWM-19-FR — Owner’s Manual Bohlmann Quality Products — www.bohlmann.com
3
2 DFWM-12-FR & DFWM-19-FR — Owner’s Manual
FIGURE 3
1/4” O.D TUBE WATER
INLET TO COOLER
3/8” O.D. UNPLATED
COPPER TUBE CONNECT
COLD WATER SUPPLY
BUILDING WATER INLET
SERVICE STOP
(NOT FURNISHED)
NOTE: WATER FLOW DIRECTION
FIGURE 4
A
SIMPLY PUSH IN TUBE
TO ATTACH
B
TUBE IS SECURED
IN POSITION
PUSH IN COLLECT
TO RELEASE TUBE
C
PUSHING TUBE IN BEFORE PULLING IT
OUT HELPS TO RELEASE TUBE
TROUBLE SHOOTING & MAINTENANCE
Orifice Assy: Mineral deposits on orifice can cause water flow to spurt or not regulate. Mineral deposits may be removed from the orifice with a small round file or small diameter wire.
CAUTION: DO NOT file or cut orifice material.
Stream Regulator: If orifice is clean, regulate flow as in
“STREAM HEIGHT ADJUSTMENT” instructions below. If replacement is necessary, see parts list for correct regulator part number.
Actuation of Quick Connect Water Fittings: Cooler is provided with lead-free connectors which utilize an o-ring water seal. To remove tubing from the fitting, relieve water pressure, push in on the gray collar while pulling on the tubing (see figure 4).
FIGURE 5
1” (25mm)
APPROXIMATELY
STREAM HEIGHT:
Stream height is factory set at
45-50 PSI. If supply pressure varies greatly from this, adjust screw on regulator in freeze resistant box.
Clockwise adjustment will raise stream and counter-clockwise adjustment will lower stream. For best adjustment, stream should hit basin approx. 6-1/2” from bubbler.
Bohlmann Quality Products — www.bohlmann.com
3
1
2
3
2
5
4
6
7
7
8
5
6
3
4
1
2
PARTS LIST
ITEM PART
400942308640 Bubbler (Dual Stream)
100322740560 Bubbler Gasket
600985551640 Drain Plug Assy.
170705042830 Basin Receptor
15013C
100147140560 Drain Gasket
55884C
55885C
DESCRIPTION
Bubbler Tube Assy.
Drain Elbow
Slip Joint Nut 1-1/4˝
9
10
66346C
97056C
Drain Tube
Freeze Resistant Box
8 9
2302 Yellow Smoke Road · PO Box 369 · Denison, IA 51442 · 800.325.2380 · www.bohlmann.com