General
Before using your ALGE-TIMING device read the complete manual carefully. It is part of the device and contains important information about installation, safety and its intended use. This manual cannot cover all conceivable applications. For further information or in case of problems that are mentioned not at all or not sufficiently detailed, please contact your
ALGE-TIMING
representative. You can find contact details on our homepage www.alge-timing.com
Safety
Apart from the information of this manual all general safety and accident prevention regulations of the legislator must be taken into account.
The device must only be used by trained persons. The setting-up and installation must only be executed according to the manufacturer’s data.
Intended Use
The device must only be used for its intended applications. Technical modifications and any misuse are prohibited because of the risks involved!
ALGE-TIMING
is not liable for damages that are caused by improper use or incorrect operation.
Power supply
The stated voltage on the type plate must correspond to voltage of the power source. Check all connections and plugs before usage. Damaged connection wires must be replaced immediately by an authorized electrician. The device must only be connected to an electric supply that has been installed by an electrician according to IEC 60364-1. Never touch the mains plug with wet hands! Never touch live parts!
Cleaning
Please clean the outside of the device only with a smooth cloth. Detergents can cause damage. Never submerge in water, never open or clean with wet cloth. The cleaning must not be carried out by hose or high-pressure (risk of short circuits or other damage).
Liability Limitations
All technical information, data and information for installation and operation correspond to the latest status at time of printing and are made in all conscience considering our past experience and knowledge. Information, pictures and description do not entitle to base any claims. The manufacturer is not liable for damage due to failure to observe the manual, improper use, incorrect repairs, technical modifications, use of unauthorized spare parts. Translations are made in all conscience. We assume no liability for translation mistakes, even if the translation is carried out by us or on our behalf.
Disposal
If a label is placed on the device showing a crossed out dustbin on wheels (see drawing), the European directive 2002/96/EG applies for this device.
Please get informed about the applicable regulations for separate collection of electrical and electronical waste in your country and do not dispose of the old devices as household waste. Correct disposal of old equipment protects the environment and humans against negative consequences!
Copyright by
ALGE-TIMING
GmbH
All rights reserved. Any duplication, either in full or in part, requires the prior written consent of the copyright holder.
-2-
Manual
Timy3 - General
Declaration of Conformity
We declare that the following products comply with the requirements of the listed standards.
We,
ALGE-TIMING
GmbH
Rotkreuzstrasse 39
A-6890 Lustenau declare under our sole responsibility, that the timing device
Timy3 W-F and Timy3 WP-F
complies with the following standards/normative documents and in case of intended use complies with the basic requirements of R&TTE 1999/5/EC:
Telecommunication (TC)terminal device
Short Range Device
When used as intended complies with the basic requirements of §3 and the other relevant Provisions of the FTEG (article 3 R&TTE 1999/5/EC).
Health and safety according to §3(1)1. (article 3(1)a))
Applied harmonized standards…
EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013
Protection requirements with regard to electromagnetic compatibility §3 (1) 2, (article 3 (1) b).
Applied harmonized standards
EMC: EN301 489-17 v2.1.1. (2009-05) v2.2.1 (2012-09)
EN 300 328 v1.7.1 (2006-10) v1.9.1 (2015-02)
EN 55022 : 2010 / AC : 2011
EN 55024 : 2010 / A1: 2015
EN 61000 3-2:2014
EN 61000 3-3:2013
Additional Information:
The product herewith complies with the requirements of the Low Voltage Directive 73/23/EEC, also the
EMC Directive 2004/108EG and accordingly carries the CE-marking.
Lustenau, 2017-03-22
ALGE-TIMING GmbH
Albert Vetter
(General Manager)
-3-
Control elements
Manual
Timy3 - General
A .......... paper roll
B .......... thermal printer
C .......... printer hood
D .......... printer hood opener
E .......... LCD graphic display
F .......... silicon keyboard
G .......... carrying band eyelet
1 ........... USB interface
2 ........... charging socket
3 ...........
ALGE-TIMING multiport
4 ........... connection for display board
5 ........... connection for start impulse
6 ........... connection for finish impulse
7 ........... standard
ALGE-TIMING photocell socket
-4-
Manual
Timy3 - General
Table of contents
Change of Paper for Timy3 WP (Design 2) ....................................................... 14
Change of Paper for Timy3 WP (old Design) ..................................................... 14
Synchronization of Timy3 from another Timing Device ...................................... 15
Synchronization of other Devices with Timy3 by Cable ..................................... 16
Synchronization of Timy3 to Timy3 by WTN ...................................................... 17
-5-
Manual
Timy3 - General
-6-
Manual
Timy3 - General
1 Device Description
The
ALGE-TIMING
Timy3 is a handy device, equipped with high-quality technology.
In spite of the handy dimensions, the Timy3 provides a large and easy-to-use silicone keypad.
The model Timy3 WP has an integrated printer that records the entire competition.
The Timy3 is also equipped with the necessary interfaces for communication with external devices: interface for display boards, RS232 interface for communication with a computer,
RS485 interface to establish a network of timing devices and future-proof USB interface.
The memory of the Timy3 can store up to 30,000 times which can be shown on the display or transmitted to a computer by RS232 or USB interface at any time.
The integrated radio modem WTN allows linking the Timy3 via radio with all devices of the
WTN series.
For operating the Timy3 with the internal radio module please also refer to the manual WTN.
1.1 Timy3 Models
Both Timy3 models are equipped with a temperature compensated quartz-oscillator and therefore suited for highest accuracy. The extended temperature range allows operating the Timy3 from +50°C until -20°C (for summer and winter sports).
Timy3 W:
Timy3 W is a timing device without printer.
Timy3 WP (Design2):
Timy3 WP is a timing device with integrated printer.
-7-
Manual
Timy3 - General
1.2 Timy3 Software
Available programs for the Timy3:
Stopwatch: universal timing program which is suitable for several heats (run/total time)
Backup:
PC-Timer: to measure time of day times (e. g. as backup-system or as time reference for the computer) to measure time of day times with simultaneous output of the running time in 1/10 seconds via the RS232 interface; ideal as an accurate timing device for the computer
LapTimer:
TrackTimer: timing program with run times and lap times (e. g. for motor sport) timing program for events with several lanes, e. g. athletics and swimming
Training Lite: universal training software (several intermediate times are possible)
Training REF: training software with reference run (several competitors on course)
Speed: speed measurement
Commander: terminal for diverse subprograms (see manual)
CycleStart: program for track cycling with countdown and lap counter
Terminal: terminal for judges (e. g. gymnastics)
Track + Field: for measuring the wind speed with anemometer WS2, to control a concentration clock and infield display board
Parallel-Diff: timing for parallel slalom (difference time of both slopes)
Dual Timer:
Timeout: timing of two separate courses timing with timeout, also applicable for show jumping (with start countdown)
Swim Trainer: training program for swimming
Jumping: training program for jump trials, measures jumping height on the basis of time between jump and landing on a contact mat (several subprograms)
Speed-Climbing: timing for parallel competitions at speed climbing with false start
Start-Liner: to control Startclocks ASC3 or display boards D-LINE when using individual start time (e.g. Gunderson start)
Parallel-Start: to control and input start doors for opening with a different time delay
TV-Timer: simple timing program for controlling a display board or TV time flashes
Voting: radio judging console (WTN) for judges, voting, etc. (e.g. ski jumping)
Safe Driving 2: to control a display board and speed measurement for driver training
CC False Start: false start detection for cross country skiing sprint events
1.3 Driver Installation
For installation of drivers, separate manuals are available. You can download them from our website www.alge-timing.com
or contact your
ALGE-TIMING representative.
-8-
Manual
Timy3 - General
1.4 Keypad
The Timy3 has a weather-proof (water-proof) silicone keypad. The keypad is ideal for outdoor use. The keys are raised and have ideal pressure points. Although the Timy3 is small in dimensions, the keys are easy to operate.
Control keys: all-purpose keys; the function of each one is always visible on the display.
START/ON: manual start impulse and switch on the Timy3
STOP/OFF: manual stop impulse and switch off the Timy3
Printer: paper output; combination and , opens printer menu
2nd: always used in combination with a second key (additional function)
+
+
Menu: enter the device menu
CLR: clear the marked times or memory
Cursor: move the cursor in the display beginning of a list end of a list
OK green: switch on, confirm commands or start inputs
OK red: switch off, confirm commands or finish inputs
-9-
Manual
Timy3 - General
1.5 Display of Timy3
The Timy3 has a display with backlight. The backlight makes reading of the display at bad light conditions easier. As the backlight consumes energy it is only switched on automatically when the Timy3 is connected with an external power supply (e. g. PS12A). If you use the Timy3 in battery mode you can switch on the backlight in the menu.
•
Press menu key.
•
Select <DISPLAY> with arrow down key.
•
Press OK key (red or green).
•
Select <Back Light> with arrow down key.
•
Press OK key (red or green).
•
The display shows:
ENERGY-SAVE: external supply: battery operation:
ON:
AUTOMATIC: external supply: battery operation: display back light on (100 % brightness) display back light off display back light on (100 % brightness) display back light on (50 % brightness)
After each key stroke or timing impulse the back light is on for 5 seconds.
•
Choose desired light function with arrow down key.
•
Press OK key (green or red).
•
Exit menu by pressing menu key.
-10-
Manual
Timy3 - General
1.6 Choose Language
Currently, you can choose between the following languages: German, English, French, Italian,
Spanish, Finnish and Dutch.
•
Press menu key.
•
Select <GENERAL> or <ALLGEMEIN> with arrow down key.
•
Press OK-key (red or green).
•
Select <LANGUAGE> or <SPRACHE> with arrow down key.
•
Press OK-key (red or green).
•
The display shows: display in English display in German
•
Select desired language with arrow down key.
•
Press OK key (green or red).
•
Exit the menu by pressing menu key.
-11-
Manual
Timy3 - General
2 Start Up
2.1 Switch On
•
Press „START/ON“ key.
•
Display shows:
“Really switch-on? Press the green OK button!“
•
If you press the green OK key within 10 seconds, the Timy3 switches on, otherwise it automatically switches off again.
2.2 Switch Off
You have got two possibilities to switch off the Timy3:
Method 1:
•
Press „STOP/OFF“ key for 3 seconds.
•
Display shows:
“Really switch-off? Press the red OK button!“
•
If you press the red OK key within 10 seconds, the
Timy3 switches off, otherwise it returns to the program.
Method 2:
•
Press „2nd“ and „STOP/OFF“ keys
•
Display shows:
“Really switch-off? Press the red OK button!“
•
If you press the red OK key within 10 seconds, the
Timy3 switches off, otherwise it returns to the program.
2.3 Power Supply
The Timy3 has several possibilities for power supply:
External supply +8 to 24 VDC:
•
power supply unit PS12
•
power supply unit PS12A, ideal as the Deltron socket remains free
•
external battery e. g. 12V plumb rechargeable battery
• ALGE-TIMING display board (e. g. GAZ4 or D-LINE)
NLG4 and NLG8 must NOT be used as the off-load voltage is too high. The Timy3 might be destroyed!
With external supply of at least 11.0 VDC, the internal rechargeable batteries are charged.
-12-
Manual
Timy3 - General
Internal supply:
The battery compartment has space for six batteries type AA or rechargeable batteries. For
Timy3 WP you have to use the heat-sealed rechargeable battery-packs ONLY!
Timy3 (Design 2)
Alkaline Batteries
Timy3 W Timy3 WP
-20°C / -4F 20°C / 68F -20°C / -4F 20°C / 68F about 50 h about 100 h not possible not possible
NiMH Rechargeables NM-Timy2 about 50 h about 60 h about 25 h about 60 h
This measurement took place without the Timy3 supplying external devices (e. g. no supply of photocells) and for the WP with 3 printed lines per minute.
Battery types:
Alkaline batteries: These batteries must never be used in a Timy3 with integrated printer.
Alkaline batteries can only supply about 10 % of their original capacity at temperatures of -20 °C. Thus they are only recommendable for warm weather. For environmental reasons it is also recommendable that rechargeable batteries are used.
NiMH battery pack NM-TIMY2: The NiMH rechargeable battery pack is recommended for every Timy3. These newly developed batteries dispose of an enormous persistence even at very low temperatures and can supply a high current for the printer.
Charging:
The rechargeable batteries are charged inside the Timy3 with charger PS12 or PS12A, no matter if the Timy3 is switched on or off. The charging period with NiMH batteries (NM-TIMY2) takes with 1.5 Ah approx. 14 hours.
Charging Switch:
The Timy3 has got a switch (hidden behind the battery label) for switching on or off the rechargeable battery charging.
Using alkaline batteries, the charging must be switched off - position ALKALI -, as otherwise the batteries may leak.
During the operation with rechargeable batteries, the switch should be on position NiCd/NiMH so that the rechargeable batteries are charged.
Attention: Never use alkaline batteries in a
Timy3 when the charging switch is set to NiCd/NiMH and a charger is connected.
Operating period:
The operating period depends on the Timy3 model, the batteries utilized and the ambient temperature.
-13-
Manual
Timy3 - General
3 Printer
The Timy3 WP has an integrated thermal printer. We recommend using our
ALGE-TIMING paper as it is best suited. You can recognize it by the
ALGE-TIMING
logo print on the reverse side, available with your
ALGE-TIMING representative.
3.1 Change of Paper for Timy3 WP (Design 2)
•
press printer hood opener (see picture on the right)
•
lift printer hood
•
take out paper axis
•
place the axis inside a new paper roll
•
insert paper roll with axis into Timy3
•
thread paper through tear-off edge
•
close printer hood
3.2 Change of Paper for Timy3 WP (old
Design)
•
open printer hood
•
take out paper axis
•
place the axis inside the new paper roll
•
insert paper roll with axis into Timy3
•
thread paper through tear-off edge
•
close printer hood
-14-
Manual
Timy3 - General
4 Synchronizing
The Timy3 can be synchronized with an
ALGE-TIMING
GPS-receiver GPS-A with the exact time of day. It is also possible to synchronize the Timy3 with other Timy3 or other timing devices
(e.g TdC8001).
4.1 GPS Synchronization
It is possible to synchronize the Timy3 with a GPS mouse (GPS-TY). The synchronization can be carried out in all Timy programs and is accurate to a 1/10,000 second.
•
The GPS mouse (picture: GPS 18LVC) needs no external power supply.
•
The RS232 baud rate of the Timy3 has to be set to 9600 baud.
•
In the menu <channels> the item <TED-RX> has to be deactivated.
•
The GPS synchronizes the Timy3. After this the Timy3 runs with its own precision quartz and the GPS can be disconnected. The GPS mouse can now be used to synchronize further devices.
Instead of the time of day setting, the display shows as indicated on the right. As long as it says “NO SIGNAL”, the
GPS receiver is searching for satellites.
When “OK -UTC +UTC NO” is displayed in the bottom line, the time for your region can be adjusted with keys
and . As soon as the correct time is shown, press
.
Attention!
After receipt of a valid GPS signal, the Timy3 verifies the checksum and measures the duration of the sync signal. If the sync signal is erroneous, the Timy3 carries out a reset. Thus, it is impossible to generate an invalid sync time. If the Timy3 is supplied by external power, it automatically restarts. In case of operation with internal power, the Timy3 turns off and has to be restarted.
Remove the GPS receiver from the Timy3. Press to start the selected program.
4.2 Synchronization of Timy3 from another Timing Device
The Timy3 can be synchronized via your start channel C0 from any
ALGE-TIMING
timing device. You can also synchronize multiple timing devices at the same time.
•
connect Timy3 with cable 000-xx or 004-xx to other timing device(s)
•
switch on Timy3
•
clear or save memory
•
set the time of day at which the synchronization takes place and confirm with <OK>
•
set the date and confirm with <OK>
•
trigger start (can be with the <START> key of the Timy3 or by short-outing the start line, e.g. with push button or start gate)
-15-
Manual
Timy3 - General
•
check if all timing devices started
•
trigger the start again and check if the start time is the same for all devices
•
disconnect the sync cable if the start times were the same
4.3 Synchronization of other Devices with Timy3 by Cable
The Timy3 can send a synchronization signal via channel 0 every full minute when using the programs BACKUP or PC-
TIMER.
•
Connect the Timy3 with the device to be synchronized.
•
Enter the time of day (next full minute) to be synchronized at the device.
•
Press and hold both keys, the green and red OK key of the Timy3. On the full minute the Timy3 sends a synchronization impulse. The time of day of the other timing device must now run.
-16-
Manual
Timy3 - General
4.4 Synchronization of Timy3 to Timy3 by WTN
It is possible to synchronize the Timy3 from another Timy3 via WTN. For this, the devices must be set to WTN mode and within radio range. There are two ways for synchronization.
Adjustment:
•
press button
•
move cursor with to <GENERAL>
•
enter menu <GENERAL> by pressing
•
move cursor with to <SYNC>
•
enter menu <SYNC> by pressing
•
move cursor with to <OVER WTN>
•
enter menu <OVER WTN> by pressing
•
select with key :
<SYNC OFF>
<PASSIVE> (factory setting)
<ACTIVE>
<ACTIVE PER MIN.>
4.4.1 WTN Synchronization Switched Off <SYNC OFF>
Timy3 does not output or read a synchronization time.
4.4.2 Passive Synchronization by WTN <PASSIVE>
The Timy3 can read and resume synchronization times from other Timy3. If the time deviation is more than 0.0005 seconds, the new time of day must be confirmed or rejected at the passive Timy3.
4.4.3 Single Synchronization Output <ACTIVE>
The active Timy3 that executes the synchronization outputs the time of day to all passive Timy3 once.
4.4.4 Synchronization Output every Minute <ACTIVE PER MIN.>
The active Timy3 that executes the synchronization outputs the time of day to all passive Timy3 every minute.
-17-
Manual
Timy3 - General
5 Connection of Auxiliary Devices
A wide range of devices can be operated with the Timy3. Please ask your
ALGE-TIMING representative for the possibilities.
5.1 Channels
The Timy3 has nine independent timing channels.
Attention: Channels 0 to 5 have a maximum precision of 1/10,000 seconds but channel 6 to 8 only 1/100 seconds.
5.2 Delay and Block Times
The variable delay and block times prevent generating double impulses and loosing impulses.
The delay and block times can be changed in the menu.
5.2.1 Delay Time
After triggering an impulse, further impulses of the same impulse channel are disabled for the duration of the delay time.
Default settings: start channel C0 1.0 s stop channel C1 to C9 0.3 s
5.2.2 Block Time
The block time is the theoretic minimum interval between two valid impulses of the same channel. Impulses within the block time are saved as invalid. The block time is only supported by certain programs.
That is to say, for an interval start of 30 seconds the minimum clearance is approx. 20 seconds. Thus the block time is 20 seconds, too.
5.3 Diagram of Delay and Block Time
4
5
6
7
∆ t
1
2
3 timing channel triggered timing channel is triggered – valid time is saved – block time starts end of impulse – delay time starts timing channel is triggered within the delay time – no impulse triggering end of impulse – delay time restarts timing channel is triggered within the block time – invalid time is saved but not printed end of impulse – delay time starts timing channel is triggered – valid time is saved – block time starts
-18-
Manual
Timy3 - General
6 Timy3 Update
Please visit our website www.alge-timing.com
for a free update for your Timy3 software.
6.1 Update Firmware with USB cable
•
If not done yet, the Timy3 USB driver has to be installed. An instruction for this can be found on our website https://alge-timing.com/download/Software/Driver/TimyUSBDriver.exe
•
log into the internet
•
start your web browser
•
input the following link: https://alge-timing.com/alge/download/software/IM.exe
•
download the file and start the install manager “IM.exe”
•
click on the folder “Timy USB”
•
connect Timy3 with the USB cable to the PC
•
start Timy3 – the program automatically searches for the Timy3
•
As soon as the firmware recognizes the Timy3, the following is displayed
•
Choose a method of updating the Timy3. Recommendable is an internet update as the latest version is always available
•
7 Memory
The memory of the Timy3 can store approx. 30,000 times.
When switching on, the memory can either be saved or deleted. The free and saved space is indicated.
-19-
Manual
Timy3 - General
8 Info Menu
Pressing the buttons opens the info mode. Important data is displayed.
•
INFO = TIMY
•
INFO2 = Timy2
•
INFO3 = Timy3 / INFO3W – WTN module activated
•
EXP = operation with external supply
•
cts = RS232 cable on channel 1
•
VERS = downloaded software version
•
BOOT = boot version
•
LEVEL = shows from which level the battery voltage is with external supply too low to operate the printer; below this level, the printer is automatically switched off in order to save battery
•
USB = PC is connected via USB-cable with Timy
•
Ubatt = current battery voltage
•
Ua = current output voltage
•
Ser-Nr = device serial number – alternating every second with HW_SN
•
HW_SN = hardware serial number without external supply
•
C0 – C3 = channel number is here if the channel is not triggered. When the channel is triggered, the channel number and a black bar appear alternately.
•
PRI INT = Timy with printer
•
PRI EXT = Timy without printer
By pressing the left or right arrow buttons, the calibration date is shown. You return to the info menu with the same buttons.
9 Menu
The Timy3 menu allows you to adjust individual settings. Push menu. With the cursor buttons you can navigate through the menu. enter or exit the menu navigate up or down
to access the main next submenu previous menu confirm input or choice
On the following pages the different menu items are described. The program specific menu settings are described in the separately available manuals for each program. Settings printed bold are the
ALGE-TIMING
factory settings.
-20-
Manual
Timy3 - General
9.1 CLASSEMENT
The ‘classement’ menu offers different options to print results.
9.1.1 ALL
Prints an overall ranking of different saved times. According to each program the following options are available:
•
<RUNTIME> ranking sorted according to run time
•
<TOTALTIME> ranking sorted according to total time
•
<PRINT MEMORY> prints the memory of Timy3
•
<MEMORYTIME> prints times of previous heat
•
<PROTOCOL> prints a protocol of all times
9.1.2 CLASS
This prints a ranking list of one class. Subsequently, the bibs belonging to this class have to be chosen. Only one class can be printed at a time.
9.1.3 START LIST
This function prints the start list of the second heat (only if a heat was finished before).
9.2 GENERAL
In this menu item general settings regarding the timing can be made.
9.2.1 PREC-ROUNDING
Choose precision and mode for calculation of times. The bold printed setting is the factory setting.
9.2.1.1 PRECISION
This is for setting the calculation precision. Only for net times!
•
<1s> calculated times in seconds
•
<1/10>
•
<1/100> calculated times in 1/10 seconds calculated times in 1/100 seconds
•
<1/1000> calculated times in 1/1 000 seconds
•
<1/10000> calculated times in 1/10 000 seconds
9.2.1.2 ROUNDING
All times are always calculated in day times in 1/10 000 seconds. For conversion to the runtime at the required precision, one of the following three methods can be chosen:
•
<CUT>
•
<UP> cuts off the figures not displayed rounds up the last displayed figure
•
<ROUND> mathematical rounding of last displayed figure
9.2.2 CHANGE HEAT
Depending on the active program, this item enables moving on to the next heat.
9.2.3 STN-AUTOMATIC
The Timy3 supports different types of automatic start number continuation for the competitors at start and finish.
9.2.3.1 START
This controls the start number continuation for competitors at the start.
•
<MANUALLY>
•
<UP>
•
<DOWN>
-21-
Manual
Timy3 - General
9.2.3.2 FINISH
This controls the start number continuation for competitors reaching the finish.
•
<MANUALLY>
•
<START>
•
<FINISH > no automatic continuation only 1 competitor on track from start to finish several competitors on track, according to starting order
9.2.3.3 AUTOMATIC-TIME
Set a minimum and maximum runtime. If an impulse is received before the minimum time has expired, an invalid time is registered. If the maximum time has expired the finish start number is automatically forwarded to the next started competitor.
•
<AUTOTIME-MIN> Standard: 00:00:00 = function disabled
•
<AUTOTIME-MAX> Standard: 00:00:00 = function disabled
9.2.4 SEC-MODE
This function sets if runtime is displayed in min/sec or just sec. Not available in all programs
•
<NO> Runtime in hh:mm:ss.th
•
<YES> Runtime in ssss:th
9.2.5 LANGUAGE
You can adjust the following languages as defaults for the Timy3
•
<GERMAN>
•
<ENGLISH>
•
<FRENCH>
•
<ITALIAN>
•
<SPANISH>
•
<FINNISH>
•
<DUTCH>
•
<SWEDISH>
9.2.6 STANDARD
Reset the Timy3 to the factory defaults.
•
<STANDARD-SETT>
9.2.7 HARDWARE
This menu is only available for our service technicians.
9.2.8 HARDWARE 2
This menu is only available for our service technicians.
9.2.9 PROGS ON OFF
As standard all programs are activated. The programs that are not used can be hidden to reduce the select list. Hidden programs can be activated any time in this menu again.
9.2.10 GPS LEP SEC.
The earth rotates a little slower than what was the basis of the second’s definition. As a result, an actual day lasts a fraction of a second longer than 86400 seconds. This effect adds up.
Therefore, an additional leap second is inserted from time to time. If the Timy3 is always updated with the latest firmware, the leap second is automatically updated with the new firmware. Alternatively, you can enter the leap second manually.
9.2.11 CLR MEMORY
You can clear the memory of the Timy3 in this menu at any time.
-22-
Manual
Timy3 - General
9.2.12 AUTOMATIC PROG
If <ON> is selected in the automatic program, the Timy3 always starts with the program currently in use (for example Stopwatch).
This feature is recommended if the user always uses the same program.
9.2.13 SYNC
You can re-synchronize the Timy3 in this menu (enter new time of day).
9.3 CHANNELS
Configuration of the timing channels:
9.3.1 INTERNAL
9.3.1.1 DELAY
The delay time of the internal timing channels c0, c1, c2, c3, c4, c5, c6, c7 and c8 can be set.
Delay time is the time after which the channel is blocked after an impulse, to prevent multiple
•
<DELAY START C0>
•
<DELAY C1-C8>
•
<DELAY C1>
•
<DELAY C2>
•
<DELAY C3>
•
<DELAY C4>
•
<DELAY C5>
•
<DELAY C6>
•
<DELAY C7<
•
<DELAY C8> standard is 1.00 second standard is 0.30 second not always available!
9.3.1.2 0.1s-CORRECTION
If impulses are transmitted by the TED or an external WTN, the 0.1 seconds delay can automatically be corrected for every channel. This function is not adjustable at the Timy3 when the internal WTN is activated as the correction is then automatically activated.
9.3.1.3 EDGE
This is for setting of triggering the impulses either on closing and/or opening. Standard for all channels is on closing (falling edge).
For channel C0, C1, C2, C3, C4 and C5 the edge is adjustable. You can either set each of these 6 channels individual or all together.
C0 – C5:
+
AS TRIGGER impulse when contact is closing (factory setting) impulse when contact is opening impulse when contact is closing and opening
When an impulse comes from the WTN (radio), it is processed via the edge in Timy3 and not as a data packet. This is important for synchronization. This setting is only available if you adjust C0
- C5 (not for a single channel).
You can adjust at the WTN if a timing impulse has an output of the falling edge <EDGE1> or of both edges <EDGE2>.
-23-
Manual
Timy3 - General
Example for falling edge EDGE1:
In the following diagram is dt
the delay time for the falling edge (blue).
Example for rising EDGE2:
In the following diagram is dt
the delay time of the falling edge (blue) and dt
the delay time of the rising edge (red).
9.3.2 BEEP
This switches the channel beep on or off.
•
<OFF>
•
<ON> Factory default
9.3.3 TED-RX
This activates the multichannel reception by the TED-RX.
•
<OFF> Factory default
•
<ON>
ATTENTION! If this function is activated the serial interface is occupied by the TED.
9.3.4 CHANNEL-PATTERN
In this menu each single channel can be permanently activated or deactivated. This is effected by selecting the channels with the arrow buttons.
At the bottom of the display, the function keys are labelled as follows:
•
F0 „ON“ o activates the selected channel o If a second Timy is connected via RS232 or GSM, the channel of the other Timy is activated.
•
F1 „OFF“ o deactivates the selected channel o If a second Timy is connected via RS232 or GSM, the channel of the other Timy is deactivated.
-24-
Manual
Timy3 - General
•
F2 „XXX“ o The status of the channel is not changed. This is only of importance for an RS232 or
GSM connection with a second Timy. The channel of the other Timy is not changed.
•
F3 „OK“ o Current settings are saved.
9.3.5 WTN Delay
This function is only activated when the internal WTN is deactivated; i. e. if an external WTN is connected.
9.3.6 ENABLE DISABLE
In this menu you can change from SENSITIVE (factory default) to PERMANENT.
•
When set to sensitive:
When pressing the 2nd button during timing operation, the bottom line of the display shows “ C0 C1 C2 C3 “. This vanishes as soon as the 2nd button is released. When the 2nd button is kept pressed, the channels can be blocked by keeping pressed the function keys F0 to F3 of the respective channel.
Example C1: - 2nd and F1 pressed: display „-“, the channel is blocked
- release F1: display „C1“, the channel is active
This function is only available for channel 0 to 3 and only works if the respective channel has not been deactivated in the menu CHANNEL-PATTERN (see 10.3.4).
•
When set to permanent:
When pressing the 2nd button during timing operation, the bottom line of the display shows “ C0 C1 C2 FIX “. With pressed 2nd button and F3 the display can be changed in order to permanently show the channels. With the arrow buttons you can now also access the channels C4 to C8. With UNFIX the permanent display of the channels can be cancelled. There are three different settings for each channel.
Example C1: - „C1“: the channel is active
- „-1-“: the channel is permanently blocked
- “?1?“: the channel is active but treated as invalid; the print-out shows a “?“ for this channel
As long as the channels are displayed permanently, the menu ENABLE DISABLE is not active, i. e. it cannot be set from permanent to sensitive. After resetting the display with UNFIX, the menu ENABLE DISABLE can once again be accessed.
9.3.7 CHANNEL-USAGE
This is only relevant in case WTN devices (e. g. PR1aW) are used in socket mode. You can set which socket (numbered as T1, T2, etc.) is treated as which channel. At the top right of the display the number of sockets is shown.
9.3.8 PULSE HOLD
You can set the interval for the falling and rising edge of each channel. The interval determines at what moment a pulse hold is shown in the display. Depending on the set edged, the interval for the idle signal or triggered signal of the timing channel can be set.
-25-
Manual
Timy3 - General
9.4 DISPLAY
This is for setting the Timy3 display and scoreboard.
9.4.1 RUNNING TENTH
In the display and via interface the running time is issued in 1/10. Function is not available for all programs. Factory setting: OFF
9.4.2 DELAYTIME 1
The delay time determines for how long the intermediate times are shown on display and scoreboard. The display time can be set e.g. for intermediate times of the running time in seconds. Moreover, this time is also applied for the automatic start number continuation at the finish. Factory default is 03 seconds.
9.4.3 DELAYTIME 2
This is for setting the display time for total time. Factory default is 03 seconds.
9.4.4 BACK LIGHT
This is to adjust the backlight of the display. Factory default is <ENERGY SAVE>.
9.4.4.1 ENERGY SAVE
Backlight is switched on during external power supply, switched off during battery supply.
9.4.4.2 ON
Backlight is always switched on.
9.4.4.3 AUTOMATIC
Backlight is switched on for 5 seconds with each keystroke and timing impulse.
9.5 INTERFACE
Settings for the RS232 and scoreboard interface. Some settings are only available in certain programs.
9.5.1 DISPLAYBOARD
These are settings for
ALGE-TIMING
displays of the type D-LINE or GAZ.
•
< BRIGHTNESS > adjusts the brightness (0 – 9) of the LED display board
•
< TIME + DATE> internal time and date of scoreboard is synchronized
•
<DISPLAY MODE> without function
•
<BAUDRATE> standard is 2400, the baud rate of the Timy3 and also of the scoreboard is set
•
<TIMEOUT>
•
<ADRESS>
•
<SAFETY CAR>
•
<LAPS> period after which the display switches to time of day address for LED display board display mode permanent or flashing
•
<CTD LAP>
•
<FORMAT> number of laps manual or automatic output of time of day or match time
•
<BOAED ON OFF> OFF: no display board data output
ON + WTN OFF: display board data output via interface
(banana socket), but not via WTN (radio)
ON + WTN ON: display board data output via interface
(banana socket) and WTN (radio)
•
<STANDING TIMES> adjustment in program LapTimer between running time
(factory setting) and standing time (only stop times)
-26-
Manual
Timy3 - General
9.5.2 RS232
These are settings of the RS232 of the Timy3.
•
<MODE> adjustment for output of net time (calculated run time) and time of day or only time of day
•
<BAUDRATE> adjustable is 2400, 4800, 9600 or 19200 Baud
•
<SEND MEMORY> sends the memory contents of the Timy3
•
<HANDSHAKE> with or without RTS-CTS handshake adjustment
•
<TRACK-MODE> norm or ident: change output format of TrackTimer
•
<TIMY<->TIMY> communication between two Timy3 (program Stopwatch)
9.5.3 GSM-MODEM
These are settings for a GSM-modem communication. GSM-modems are no longer available!
•
<ENTER NR>
•
<SEARCH MODEM >
•
<MEMORY SMS enter the number to dial search a connected modem
•
<PIN CODE> enter the SIM card pin code
•
<STOP GSM-MODEM> disconnect the connection send the memory by SMS
9.5.4 GSM-SETTINGS
These are settings for a GSM modem connection. GSM-modems are no longer available!
•
<TEL-NR 1> input of the phone number that it dials
•
<TEL-NR 2>
•
<SMS MAX PAK>
•
<CONFIG> input of the 2nd phone number that it dials
9.6 PRINTER
This menu is for setting the printer parameters.
9.6.1 PRINTER-MODE
•
<PRINTER OFF> printer is switched off
•
<PRINTER ON > printer is switched on (factory setting)
•
<PAUSE> printer stops and times will be saved and printed when printer is switched on again
9.6.2 PRINT STARTTIME
Adjustment if start time is printed immediately after the start.
•
< PRI START OFF> prints no start time (factory setting)
•
< PRI START ON> prints start time
9.6.3 AUTO LINE FEED
Adjustment of line feeds after printing a data package. It is adjustable between 0 and 9.
•
<0> factory setting is zero
9.6.4 START-LOGO
Adjustment whether the
ALGE-TIMING
logo is printed when switching on the Timy3.
•
<OFF> no logo is printed
•
<ON> logo is printed (factory setting)
9.6.5 PRINT DAYTIME
Adjustment whether the time of day is printed.
•
<OFF> no time of day is printed, only net times (run times)
•
<ON> time of day is printed (factory setting)
-27-
Manual
Timy3 - General
9.7 PROGRAM
This function allows switching to another Timy3-program.
ATTENTION: When changing the program all saved times must be deleted!
9.8 Program Specific Settings
Depending on active program this menu item is different.
9.9 WTN
The
ALGE-TIMING
WTN is a radio network consisting of several devices of the WTN-series .
Within the network, devices can communicate with each other using other devices; i.e. the communication is carried out from one device to another through a third one. The network is intended for simultaneously transmitting display data (e.g. for
ALGE-TIMING
GAZ or D-LINE), serial RS232 data (e.g. to a PC) and timing impulses.
The system is designed in such a way that the Timy3 is at the same time master and time server. Therefore, you should pay attention to the following facts:
1. The Timy3 should always be switched on as first device so that all participants can synchronize with it.
2. During operation, the Timy3 should not be switched off and on. This would require a resynchronization which could lead to the loss of timing impulses during the first 5 minutes.
In this menu item, the WTN specific settings can be executed (further explanations see also
Manual WTN ).
A Timy2 with an external WTN can be operated in nearly an identical way as a Timy3. However, there are two essential differences:
•
The Timy3 can switch off the WTN module in order to save energy.
•
The channels of the Timy2 with external WTN module are physically triggered. This means that triggering the channels also exists on the banana sockets. This is not the case for the Timy3.
9.9.1 WTN POWER
This is for switching on and off the internal WTN module. For energy saving reasons, the module is deactivated by default. For using the functions of the WTN, it must be turned on.
•
<OFF> Standard
•
<ON>
9.9.2 STATE
1 ...... switch to screen 2 by pressing key and at the same time
2 ...... number of direct neighbors (also other teams on the same frequency)
3 ...... number of devices in same team
4 ...... teams on same frequency
5 ...... transmission power: (10 – 100 mW)
6 ...... link quality indicator
7 ...... receive signal strength indicator
8 ...... firmware version of WTN
9 ...... adjusted team
10 .... adjusted channel
11 .... adjusted edge mode
12 .... adjusted Baud rate for display board
13 .... adjusted Baud rate for RS232
14 .... transmission status
-28-
Manual
Timy3 - General
Link Quality Indicator (Lqi):
* ........... poor link quality
** .......... medium link quality
*** ........ good link quality
Receive Signal Strength Indicator (Rssi):
-127 ..... no connection
-65 ....... worst receive signal strength quality
+20 ...... best receive signal strength quality
Transmission Status:
0 to 4 ........ impulse on channel
C ............... delayed channel times by RS485
G............... data for display board
S ............... serial data
V ............... version conflict within the network
P ............... pulse hold message
M .............. update or settings package
R ............... RS485 command
9.9.3 SETTINGS
•
<RADIO POWER>
•
<RS232>
•
<EDGE>
•
<RF-UPDATE>
10 (standard), 25, 50 100 mW
OFF, ON (standard)
↑
only rising,
↑+↓ rising and falling
ON, OFF (start with F0 and cancel with F1); at least one participant must be connected
•
<ADVANCED SETT.> menu is blocked (only for ALGE factory settings)
9.9.4 TEAM
Settings of the team (1-9 A-F) – see also Manual for WTN
9.9.5 SOCKET
It is possible to configure nine timing channels in this mode for the WTN. Impulses taken in the socket mode are marked with ‘t’ in the front (e.g. t0124 ST 10:12:34.0384
)
•
Start the external WTN impulse devices and adjust them to the same team as the Timy3 (e.g. photocell PR1aW, push button WTN-PB).
•
Make sure that the WTN is activated in the Timy3.
•
Press the menu button .
•
Select <WTN> and press .
•
Select <SOCKET> and press .
•
Under “Neighbors” it must now show the number of impulse devices that you have activated.
•
Select with the F-keys the device that you want to read
(e.g. F3 = all WTN-devices).
•
Initiate an impulse on the start impulse device (C0).
•
1 SOCKETS is displayed.
•
Initiate an impulse on the next impulse device (C1).
•
“2 SOCKETS” is displayed.
•
etc.
•
When you are finished press the menu button
•
Start your timing.
.
-29-
Manual
Timy3 - General
9.9.6 STATISTICS
It shows the number of data strings that have not reached the Timy3. The data is displayed per team.
9.9.7 BROADCAST PARM
It is adjustable if you want to send the adjusted WTN parameter of this Timy3 to other WTN devices in the team or not.
•
<DO NOT SEND> WTN parameter are only valid for this Timy3
•
<SEND PARAMETER> adjusted WTN parameter are broadcasted to all other
WTN devices in the team
9.10 KEYBOARD-LOCK
This activates the keypad lock in order to prevent accidental entries. All keys of the Timy3 are disabled. Disable the keyboard lock by entering 1 2 3 4 5 6.
10 Timy Messages
When using the Timy3 it might occur that messages show up on the display. These messages inform the operator about problems or unusual operating conditions.
10.1 Long Time Timing Impulse
If the Timy3 receives a very long or endless timing impulse one channel, this message is shown. The operator can now check the reason for this and might fix a problem.
The duration after which the Timy3 reports a “Pulse
Hold” is adjustable in the menu under <CHANNELS> and <PULSE HOLD>.
10.2 WTN: Old Version
An old WTN firmware version has been recognized in the network. Please update your WTN devices:
Menu-> WTN-> Settings-> Radio Update. This process can take 15 - 45 minutes. Do not switch off the devices during this time.
10.3 Delay Time for Radio Impulses
The time correction for the channel was set to 0.0 and a delayed packet was received by ra-
dio. Please setup the time correction of the channel to -0.1s.
Check 0.1sec correction
-30-
Manual
Timy3 - General
11 Technical data
Processor:
Time reference:
Time resolution:
Siemens C161 with 3.3 V technology
12.8 MHz TCXO or standard quartz
1/10,000 seconds
Running precision: Temperature compensated quartz oscillator TCXO: temperature range -25 to 50 °C: ........ +/- 2.5 ppm (+/- 0.009 sec/h) at aging: ............................................ max. +/- 1 ppm per year at 25 °C, calibrated .......................... +/- 0.3 ppm
Program memory: FLASH memory with 16 MBit
Data memory: RAM with 4 MBit, approx. 30,000 times
Display:
Keypad:
Connections: monochrome LCD graphic display 128 x 64 pixels with extended temperature range and backlight silicone keypad, 26 buttons
DIN-plug for photocell (7) banana plug pair – start input (5) banana plug pair – finish input (6) banana plug pair – display board (4)
D-sub-25 pin (3)
•
9 timing channels
•
RS232 (PC-connection)
• display board
•
RS485 (network)
• power supply (8 - 22 VDC in / 7.5 - 21 VDC out)
USB (1) power supply 8 - 22 VDC in (2)
Radio module WTN: 2.4 GHz band, integrated with 16 adjustable frequencies, adjustable output 10 to 100 mW, 5 different timing channels, range approx.
350 m at free sight
Channel extension: 5 channels per extension, max. 99 channels
Power supply: Internal:
NM-TIMY2 battery pack or
6 x AA-Alkaline 2 Ah (only for Timy3 W)
External: with charger PS12A, 12 V battery or 8 -24 VDC
Operating time (20 °C): Alkaline: without printer about 50 hours
NM-TIMY2: without printer about 60 hours
Charging:
NM-TIMY2: with printer (3 printed lines per minute) about 47 hours approx. 14 hours
Printer: graphic thermal printer, max. 5 lines per second
Temperature range: Timy3 W and WP: -20 to 60°C
Dimensions: Timy3 W: 204 x 91 x 50 mm
Timy3 WP: 307 x 91 x 65 mm
Weight: Timy3 W: 450 g (without battery)
Timy3 WP: 650 g (without battery and paper)
-31-
Manual
Timy3 - General
11.1 Pin Assignment
USB Interface (1):
The USB interface is used as interface between Timy3 and computer. Via this interface the Timy3 can be controlled completely and all data can be recalled.
Charger Connection (2):
ALGE-TIMING
Multiport (3):
Pin assignment:
1 ......... .......... terminal numbering connection
2 ......... c0....... start channel (precision 1/10,000 s)
3 ......... c2....... timing channel 2 (precision 1/10,000 s)
4 ......... c3....... timing channel 3 (precision 1/10,000 s)
5 ......... c7....... timing channel 7 (precision 1/100 s)
6 ......... .......... data output for display board
7 ......... .......... RS485B
8 ......... .......... RS485A
9 ......... .......... clock for terminals CLK
10 ....... .......... RS232 TX
11 ....... .......... RS232 RX
12 ....... .......... common ground GND
13 ....... .......... stabilized voltage out (+5 V 100 mA limited, short circuit proof)
14 ....... c1....... stop channel (precision 1/10,000 s)
15 ....... c5....... timing channel 5 (precision 1/10,000 s)
16 ....... c8....... timing channel 8 (precision 1/100 s)
17 ....... c6....... timing channel 6 (precision 1/100 s)
18 ....... c4....... timing channel 4 (precision 1/10,000 s)
19 ....... .......... RS232 RTS
20 ....... .......... printer data out
21 ....... .......... horn output 8
Ω
22 ....... .......... RS232 CTS
23 ....... .......... power supply out: 7.5 - 21 VDC 2A max.
24 ....... .......... common ground GND
25 ....... .......... power supply in: 8 - 22 VDC
-32-
Manual
Timy3 - General banana plugs for display board banana plugs for start channel C0 banana plugs for stop channel C1
(4)
(5)
(6)
Photocell socket (7)
Pin assignment:
1 ............ c0 .......... start channel
2 ............ c1 .......... stop channel
3 ............ GND...... common ground
4 ............ +Ua ...... power supply out 8-22 VDC (only on external supply)
5 ............ +5V ...... stabilized voltage out (+5 VDC 100 mA limited)
6 ............ c2 .......... intermediate time channel
-33-
Manual
Timy3 - General
12 Interfaces
12.1 RS232 Interface
Output format:
Bit rate:
1 start bit, 8 data bit, no parity bit, 1 stop bit
9600 baud factory setting adjustable: 2400, 4800, 9600, 19200, 28800, 38400
Transmission protocol: ASCII yNNNNxCCCxHH:MM:SS.zhtqxGGRRRR(CR) y ................................ first figure is blank or info (see below) x ................................ blank
NNNN ........................ start number, max. 4-digit, any pre-zero is not shown
CCC .......................... channels of timing device c0 .............................. channel 0 .......... start channel c0M ........................... channel 0 ......... triggered by keypad <START> c1 .............................. channel 1 .......... finish channel c1M ........................... channel 1 .......... triggered by keypad <STOP> c2 .............................. channel 2 c3 .............................. channel 3 c4 .............................. channel 4 c5 .............................. channel 5 c6 .............................. channel 6 c7 .............................. channel 7 c8 .............................. channel 8
RT ............................. run time
TT ............................. total time
SQ ............................. sequential time (lap time) kmh ........................... speed measurement (possible displays: km/h, m/s, mph)
HH:MM:SS.zhtq......... time in hours, minutes, seconds and 1/10,000 seconds
GG ............................ group, lap or blank
RRRR ........................ rank (only available in ‘classement’ menu)
(CR) .......................... carriage return
Info – the following figures may be in first position: x ................................ blank (valid time)
? ................................ time without valid start number m ............................... time from memory (no bib) c ................................ times deleted (e.g. with CLEAR button)
C ............................... memory time deleted (e.g. with CLEAR button) d ................................ times deleted due to disqualification i ................................. manually entered valid time with <INPUT> n ................................ enter new start number t ................................. valid time with radio correction received via TED RX or WTN
Example of an RS232 interface output (e.g. program backup)
0001 c0 15:43:49,8863 00
0002 c0 15:43:50,1647 00
0005 c1 15:43:51,6464 00
0006 c0 15:43:51,9669 00
0007 c1 15:43:52,2467 00
0008 c0 15:43:52,4579 00
0009 c1 15:43:52,6941 00
0015 c0M 15:43:55,6200 00
0016 c1M 15:43:55,8800 00
0019 c0M 15:43:57,020 00 m 0007 c0 15:43:59,9927 00
-34- m 0008 c1 15:44:00,2849 00 m 0009 c0 15:44:00,5499 00 m 0010 c1 15:44:00,8182 00 m 0011 c0 15:44:01,0366 00
C 0011 c0 15:44:01,0366 00 n 0014 c0 15:44:01,0366 00
0020 c0 15:44:15,0077 00
0022 c0 15:44:15,5165 00
0023 c1 15:44:15,7847 00 c 0023 c1 15:44:15,7847 00 i 0023 c1 15:44:15,7847 00
Manual
Timy3 - General
-35-
Manual
Timy3 - General
-36-
Manual
Timy3 - General
12.2 RS485 Interface
This interface is only used for special applications such as wind speed measurement, Timy3
Terminal etc.
12.3 Interface for Display Board
Output format:
Bit rate:
1 start bit, 8 data bits, no parity bit, 1 stop bit factory setting: 2400 baud (for
ALGE-TIMING
GAZ display board)
2400, 4800, 9600, 19200, 28800, 38400
Transmission protocol: ASCII
NNN.xxxxxxxxM:SSxxxx(CR) ............... running time (without 1/10 seconds)
NNN.xxxxHH:MM:SSxxxx(CR) ............... running time (without 1/10 seconds)
NNN.xxxxHH:MM:SS.zxx(CR) ............... running time (with 1/10 seconds)
NNNCxxxxHH:MM:SS.zhtRR(CR) ........... channel C1 finish time with rank
NNNCxxxxHH:MM:SS.zhtxx(CR ) ........... channel C1 finish time without rank
NNNDxxxxHH:MM:SS.zhtRR(CR ) ........... channel C1 total time with rank
NNNDxxxxHH:MM:SS.zhtxx(CR) ........... channel C1 total time without rank
NNNAxxxxHH:MM:SS.zhtRR(CR) ........... channel C2 1. intermediate time
NNNBxxxxHH:MM:SS.zhtRR(CR) ........... channel C3 2. intermediate time
NNNExxxxHH:MM:SS.zhtRR(CR) ........... channel C4 3. intermediate time
NNNFxxxxHH:MM:SS.zhtRR(CR) ........... channel C5 4. intermediate time
NNNGxxxxHH:MM:SS.zhtRR(CR) ........... channel C6 5. intermediate time
NNNHxxxxHH:MM:SS.zhtRR(CR) ........... channel C7 6. intermediate time
NNNIxxxxHH:MM:SS.zhtRR(CR) ........... channel C8 7. intermediate time
NNNSxxx©xxxxsxss.ssxRR(CR) ........... speed
NNN ....................... start number (hundreds, tens, ones - digit 1 to 3)
. ............................ point on the fourth digit is the identification for a running time
HH:MM:SS.zht ....... time in hours, minutes, seconds and 1/1000 seconds
© ............................ speed measurement: output of following ASCII signs: 01 hex for km/h, 02 hex for m/s, 03 hex for mph
RR .......................... rank x ............................. blank
(CR) ....................... carriage return
13 USB Interface
Currently possible applications for USB interface:
•
update the Timy3 software with installation manager or Timy3 USB program
•
query and change of settings (as RS232)
•
recording of times with program ComtoFile
•
evaluation with program Time.NET
•
evaluation with program Excel Writer
-37-
Manual
Timy3 - General
-38-
Manual
Timy3 - General
-39-
Manual
Timy3 - General
Subject to changes and misprints
Copyright by
ALGE-TIMING
GmbH
Rotkreuzstr. 39
6890 Lustenau / Austria www.alge-timing.com
-40-

Public link updated
The public link to your chat has been updated.
Advertisement