DARKLAB HOVER User Manual
Darklab Hover is a state-of-the-art power supply that offers a range of features to enhance your tattooing experience. With its intuitive touchless operation and gesture control, you can easily adjust voltage, navigate menus, and start/stop your machine without touching the device. The dual timer allows you to track both session and machine run-time, while the 9 programmable banks let you save and recall your preferred settings. Compatible with both rotary and coil machines, the Hover provides a stable and reliable power source for all your tattooing needs.
Advertisement
Advertisement
Power Supply
USER MANUAL
2019
INDEX
Safety Notice
Device Overview
Basic Operation
Default Screen
Menu Screens
Additional Information
5
6
3
4
7
10
USER MANUAL
SAFETY NOTICE
CLASS III SYMBOL
A Class III appliance is designed to be supplied from a separated/safety extra-low voltage (SELV) power source. The voltage from a SELV supply is low enough that under normal conditions a person can safely come into contact with it without risk of electrical shock. The extra safety features built into Class I and Class II appliances are therefore not required. For medical devices, compliance with Class III is not considered sufficient protection, and furthermore, stringent regulations apply to such equipment.
TECHNICAL DATA
Input Voltage:
Operating Voltage:
Current:
19 V
2-17 V
1.5 A
Connection:
Operating Mode:
(2) 3.5mm RCA connection
Continious operation
Ambient Temperature: +10 to +35 °C
Relative Humidity: 30 to 75%
Dimensions (W x H):
Weight:
84.8 mm x 33.6 mm
Approx. 224 g
BARRIER PROTECTING YOUR HOVER
For a visual demonstration of many barrier protection methods, please visit our FK Irons YouTube channel.
“This machine is not to be used by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge”
3
USER MANUAL
DEVICE OVERVIEW
THE HOVER
Key Features
• Touchless, gesture controlled operation for
maximum hygiene.
• Bluetooth enabled. Pair with Darklab app
for firmware updates.
• Touchless air gestures to increase
or decrease voltage & navigate menus
and settings.
• AirSwitch. Hold over center to turn on/off.
• Full rotary & coil readouts.
• Dual timer: Track session & machine
run-time simultaneously.
• USB-A & USB-C ports to charge mobile devices
& Darklab battery packs.
• Display modes:
Pro: All readouts at a glance.
Hertz: Speed priority + volts.
Volts: Voltage priority + speed.
Timer: Timer priority + volts, run and
session time.
• Rotate display feature to re-route your cables
up or down.
• Connect up to 2 machines.
• Footswitch compatible.
• Maximum current output: 1.5 A.
• Input voltage: 19V Output voltage: 2-17.0 V
• Nonslip magnetic base.
4
USER MANUAL
BASIC OPERATION
MOTION
SENSORS
Touchless Operating Gestures
The device has 2 control sensors on either side of the screeen. It is important to use smooth and complete (left to right, right to left) swiping motions.
Both sensors must be swiped across to ensure proper operation.
Cycle Through Menu Screens
Covering both sensors on the default screen for a few seconds will cycle through the function screens. It’s recommended that you use two fingers so screen is visible. Note: Connected machine will pulse when initiating cycle.
V V
Increase / Decrease Voltage
Covering left or right sensor will increase (R) or decrease (L) voltage setting.
Machine Toggle
Swiping left or right across the sensors will toggle between connected machines. (Only functions when
2 machines are connected.)
Start/Stop Attached Machine
Covering both sensors on the default screen for a few seconds will activate or deactivate connected machine.
Lock / Unlock Settings
To lock device settings, cycle through functions to lock screen. Once lock icon is displayed, swipe across both sensors to lock. To unlock, cover either sensor until locked icon appears, swipe across both sensors to unlock.
5
USER MANUAL
DEFAULT SCREEN
Insert Power Cord to Turn on Device
NOTE: Insert power cord to Hover prior to connecting to outlet.
When device is turned on, logo will flash momentarily and screen will refresh to default. This is the default operating screen when the device is on.
There are four basic operations that can be done from this screen:
Increase/decrease voltage, toggle between machines, start/stop attached machine and lock/unlock setting.
AMP
TIMER ON/OFF
BANK INDICATOR
BLUETOOTH ON/OFF
HERTZ
CURRENT VOLTAGE
DUTY CYCLE
MACHINE INDICATOR
FOLLOW THROUGH
Cycle Through Menu Screens
Covering both sensors on the default screen for a few seconds will cycle through the function screens. It’s recommended that you use two fingers so screen is visible.
Note: Connected machine will pulse when initiating cycle.
6
USER MANUAL
MENU SCREENS
Bank Management Screen
Manage, save and delete the preset banks. Device has 9 programmable banks.
Bank selection is done in default screen. Select the desired voltage before cycling to the Bank Management Screen. Once you have selected an option, wait for 3 seconds, device will automatically accept selection and switch back to default screen. New selection will default to highest bank available.
( SAVE ) ( DELETE )
RCA Port Configuration Screen
Select RCA port configuration by swiping left to right or vice versa. Configure the
RCA ports to control machine(s) using right/left footswitch combination or connect up to 2 machines.
( CANCEL )
( MACHINE RIGHT - PEDAL LEFT ) ( PEDAL RIGHT - MACHINE LEFT )
7
( MACHINE BOTH PORTS )
USER MANUAL
MENU SCREENS
Screen Configuration Screen
Select the default screen configuration, swipe right or left to cycle through 4 options.
Pro - Default Screen | Volts - Priority V + Hertz
Hertz - Priority Hertz + V | Timer - Session/Machine run time
PRO SCREEN VOLTS
HERTZ
Screen Orientation
Select the orientation of the screen:
Cables towards bottom or top.
Swipe left or right to select.
TIMER
8
USER MANUAL
MENU SCREENS
Timer Operation
This screens controls the timer: Reset / Start / Pause. Swipe left or right to cycle through controls. Displays session time as well as machine run time.
RESET
RESET TO 00:00:00
START
INITIATE TIMER
PAUSE
PAUSE TIMER
PEDAL CONFIGURATION
Select pedal/machine function. Swipe right or left to select.
On/Off Toggle: Tap for on, tap for off / or press and hold for on, release for off.
F Power: Press and hold to increase volts. Tap + Press and hold to decrease volts.
Tap to toggle on/off.
ON/OFF TOGGLE F POWER
9
USER MANUAL
ADITIONAL INFORMATION
VOLTAGE PARAMETERS
While voltage is a parameter that will vary from artist to artist, the Hover has been tested to operate at a minimum voltage of around 2 Volts with a maximum voltage of 17 Volts.
Depending on the type of needle configuration or brand you use, feel free to adjust the voltage to obtain the desired performance. NOTE: Some machines require a minimum voltage to operate correctly, please check your machine manufacturers requirements.
WARRANTY
Darklab warrants that the device will perform efficiently when used as intended. Should this product prove to be defective due to manufacturing issues, Darklab will repair/replace the device - free of charge. This warranty will be void if the device shows signs of having been tampered, disassembled, handled roughly, dropped, overexposed to moisture or damage to sensors/screen resulting in compromised functionality. Avoid scratches to screen. Always use clear barrier film while in operation.
HANDY TIPS
The following tips will help you get the most out of your Hover and avoid potential issues:
• Do not exceed the suggested voltage.
• Only use approved power adapters, failure to do so can void your warranty.
• Use only quality cables. A good connection will ensure consistent performance.
• Keep screen safe using Hover approved barrier film. Typical adhesive could interfere with sensors.
• Use only FDA-approved cold sterilization solutions for disinfection. Avoid scratching sensor windows.
• NOT AUTOCLAVABLE.
10
USER MANUAL
ADITIONAL INFORMATION
TROUBLESHOOTING
1.- Hover manufacturer
FK Irons: 1771 NW 79th Avenue, Doral, Florida 33126
2.- Firmware
It’s importatnt to keep the firmware on your Hover updated. Download the Darklab App for your
I phone or Android to recive updates and notifications about software updates.
For service inquiries, please contact [email protected].
For additional tips and tutorials, please visit our FKIrons Youtube channel.
11

Public link updated
The public link to your chat has been updated.
Advertisement