Xpr DINB 100-SA Biometric Reader User Manual
Below you will find brief information for Biometric Reader DINB 100-SA. The DINB 100-SA is a standalone biometric access control system that can store up to 97 fingerprints. It has one relay output and one exit button input. This system is designed for one-door applications and allows you to control access to a secure area based on fingerprint verification. It can be connected to a remote relay unit for secure installations where the exit button is located in a safe area.
Advertisement
Advertisement
DINB100-SA
Standalone Biometric Reader
User Manual
www.visual-plus.com
v.a1
a Visual Plus Corporation
Company
EN
Contents
1.0 INTRODUCTION
..............................................................
3
2.0 MOUNTING AND DISMOUNTING
............................................
3
3.0 SPECIFICATIONS
..............................................................
3
4.0 APPLICATION DIAGRAM
.....................................................
4
5.0 WIRING
.........................................................................
4
6.0 RECOMMENDED SWIPING TECHNIQUE
.....................................
5
6.1 Tapping the sensor ............................................................
5
6.2 Scrolling the sensor up and down ...........................................
5
7.0 INDICATION
....................................................................
5
8.0 QUICK PROGRAMMING
...................................................
6
8.1 Adding Master Finger and delete all users ...................................
6
8.2 Add User In Group 1 .......................................................
7
8.3 Add User In Group 2 .......................................................
7
8.4 Delete user .......................................................
7
8.5 Delete All Users in Group 1 .......................................................
7
8.6 Delete All Users in Group 2 .......................................................
7
9.0 KEEP THE DOOR UNLOCK
.................................................
7
10.
0 DINB100-SA PROGRAMMING MENU
.................................................
8
10.1 Adding Users
................................................................
8
10.2 Delete User .....................................................................
10.6 Delete Administrator
9
10.3 Delete All users
10.4 Delete Group of Users
...............................................................
9
............................................................
10
10.5 Add Administrator ............................................................
..........................................................
11
12
10.7 Settings .................................................................
13
10.7.1 Entry Mode and Backlight .................................................
14
10.7.2 Buzzer Sound and Remote Relay Touch Function
10.8 Set Door Relay Time
.....................................
15
.................................................
16
10.9 Adding Users In Finger On Card Mode
(when Mifare Reader is connected)
11.0 PROGRAMING DINB100-SA WITH KEYPAD
.....................
17
............................................
18
11.1 Adding Users .............................................................
18
11.2 Delete User By User Location Number .................................................
19
11.3 Delete User Group
11.4 Delete All Users
........................................................
...............................................................
19
20
11.5 Delete User by User Finger
11.6 Set Door Relay Time
11.7 Buzzer Settings
11.8 Backlight Settings
11.9 Set the Touch Button Function
11.10 Unpair Remote Relay
....................................................
20
......................................................
21
........................................................
22
......................................................
23
...................................................
....................................................
24
24
11.11
Entry Mode Settings
11.12 Add Administrator
11.13 Delete Administrator
....................................................
25
.....................................................
26
....................................................
26
www.visual-plus.com
2
1.0 INTRODUCTION
DINB100-SA is a simple one-door standalone biometric system. The reader can store up to 97 finger templates, it has one relay output and one exit button input. If secure installation is needed, the reader can be connected to remote relay unit at secured area, which also plays the role of exit push button. Proximity reader or keypad can be added for additional entry mode (Card or/and Finger, PIN Code or/and Finger, Finger on Card). Complete setup and programming can be done by scrolling and tapping on the sensor or by keypad menu if keypad is connected.
The sensor incorporates dedicated sensing hardware to facilitate the detection of “spoofing” attacks based on fake fingers. This data is embedded into the image data stream, and is processed on the processor. The system is capable of detecting and defeating well-known fake finger mechanisms, such as molded “gummy” fingers.
The coating on the surface of the TouchChip sensor provides protection from scratching and abrasion due to normal contact with fingertips and any incidental contact with fingernails.
The reader is capable of working in so called “Finger on Card” mode, where the authentication is done by verifying that the biometric data stored on the card matches the finger being placed on the reader.
2.0 MOUNTING AND DISMOUNTING
Do not install the device and cabling close to a source of strong electro-magne c fields like radio-transmi ng antenna.
Do not place the device near or above hea ng equipments.
If cleaning, do not spray or splash water or other cleaning liquids but wipe it out with smooth cloth or towel.
Do not let children touch the device without supervision.
Note that if the sensor is cleaned by detergent, benzene or thinner, the surface will be damaged and the fingerprint can't be entered.
3.0 SPECIFICATIONS
Fingerprint Capacity:
Output:
Push Button Input:
Door Open Time:
Entry Mode:
Programming:
Master/Admin Fingers:
Image resolution:
Backlight ON/OFF:
Buzzer ON/OFF:
Firmware upgrade:
Current Consumption:
Power Supply:
Indication:
Mounting:
IP Factor:
Storage/Operating Temperature :
Storage/Operating Humidity:
Dimensions(mm):
www.visual-plus.com
97 templates
1 x Relay (3A/250VAC)
Yes
Pulse (1, 3, 5, 10, 20, 30, 60sec) or Toggle(ON/OFF)
Finger
(Basic installation)
Finger or/and Card (when used with card reader DIN Card reader)
Finger or/and PIN code (when used with keypad DINPAD-M)
Finger on Card (when used with mifare reader DINMTPX-MF)
By scrolling and tapping on the sensor or by keypad
1 Master and 2 Admin Fingers
Up to 508 DPI
Yes
Yes via RS485 converter and windows application
170 mA max.
9-14 V DC
Tricolor Indication LED and 4 x Programming LEDs
Flush mount
IP40
-20°C to +50°C
5% to 93% RH without condensation
80 x 80 x 9
3
DINB100-SA
4.0 APPLICATION DIAGRAM
Op onal
2 Door remote Relay Unit
DINRTT
OR
Op onal
Keypad
1
4
7
A
2
5
8
0
3
6
9
B use the cable provided with the keypad/reader
OR
Secur ed Ar ea
Outside
DINB100-SA
Standalone Biometric Reader
Op onal
Proximity Reader
Op onal
1 Door remote Relay Unit
RTT
1 2
4 5
7 8
A 0
9
B
3
6
Note: Double DIN Frame sold separately
5.0 WIRING
Relay Output
NC
C
NO
NC
C
NO
Electric Door Strike
(DC powered)
+
-
Jumper (Adding Master Finger)
Connection to additional card reader or keypad
DINB100-SA
C
NO
NC
C
NO
12V
GND
B
A
PB
GND tamp tamp
12V
GND
B
A
PB
GND tamp tamp tamp tamp
12V
GND
PB
GND(PB)
Exit Bu on (NO)
+12V
GND
B
A
PB
GND tamp tamp
Power Supply
(9-14V DC)
RS485
Push Button
Tamper
Alarm
+
-
12 VDC
4
www.visual-plus.com
6.0 RECOMMENDED SWIPING TECHNIQUE
Follow the below instructions for correct finger swiping
Starting from the first finger joint, place the selected finger on the swipe sensor and move it evenly towards oneself in one steady movement.
Result:
For a valid swipe: Tricolour Indication LED turns green + OK Beep(short + long beep)
For an invalid or misread swipe: Tricolour Indication LED turns red + Error
Beep ( 3 short beeps)
6.1 Taping the sensor
Tap the sensor to enter Submenu or to confirm a command
Enter and confirm
6.2 Scrolling the sensor up and down
Scroll the sensor DOWN to navigate the programming menu
Navigate the Programming Menu
Scroll the sensor UP to exit the programming menu
Exit the Programming Menu
7.0 INDICATION
Tricolor Indica on LED
Green - Access Granted
Red - Access denied
Orange - Idle Mode
www.visual-plus.com
4 x Tricolor Programming LEDs
(red, green, orange)
5
OK Beep - short + long beep
Error Beep - 3 short beeps
Swipe Again - 2 short beeps
8.0 QUICK PROGRAMMING
8.1 Adding Master Finger and delete all users
1.Close the jumper on the back of the device.
2.Reset the Power of the device.
3.Wait for One long + mul ple short beeps
4.Open the jumper.
(short beeps will stop)
5.Wait for the bo om row LEDs to blink in Orange.
DINB100-SA
A B GND 12V
Blinking> <Blinking
6.Swipe the Master finger min.6 mes. (Un l Ok Beep)
x 6
Note: A er enrolling the Master finger the device will auto-Reset (wait for 7 seconds and the OK beep).
Note: This procedure also deletes all the users and administrators previously enrolled.
1. There is 1 Master Finger. The master finger can enroll/delete user and all the other se ngs. The Master finger can be changed ONLY with the jumper.
2. There are 2 Administrator Fingers. The administrator can do all the things that Master can do. The Master can delete the Administrator, but the Administrator can not delete the Master.
3. The User can be assigned to one of the 8 available User Groups. With the Quick programming feature, the Users are assigned in Group 1 or Group 2. For most of the installa ons 2 groups are enough and can be used as: Group
1 for permanent residents, Group 2 for guest and visitors.
4. The user can be deleted by swiping its user finger or by dele ng the group in which that user is enrolled. Once the Group of users is deleted, all the users within that group will be deleted.
5. The Groups are not limited by the number of users. (ex. Group 1 can contain 20 users, Group 2 can contain 70 users, but the total number must remain bellow 97...)
www.visual-plus.com
6
8.2 Add User In Group 1
Figure.1
1. Swipe the Master or Admin Finger
2. Swipe the user finger min. 6 mes (un l Ok Beep)
8.3 Add User In Group 2
Figure.2
1. Swipe the Master or Admin Finger twice
2. Swipe the user finger min. 6 mes (un l Ok Beep)
8.4 Delete User
Figure.1
1. Swipe the Master or Admin Finger
2. Swipe the user finger(already enrolled)
8.5 Delete All Users in Group 1
6 sec.
1. Swipe the Master or Admin finger 3 mes,
2. Wait 6 seconds for the light pa ern on figure.4
3. Swipe the Master or Admin finger once more
Note: All fingers that are enrolled in Group 1 will be deleted.
8.6 Delete All Users in Group 2
6 sec.
1. Swipe the Master or Admin finger 4 mes,
2. Wait 6 seconds for the light pa ern on figure.6
3. Swipe the Master or Admin finger once more
Note: All fingers that are enrolled in Group 2 will be deleted.
Master Finger x 1
User Finger x 6
Master Finger x 2
User Finger x 6
Master Finger x 1
User Finger x 1
Master Finger x 3
wait 6 seconds
Master Finger x 1
Master Finger x 4
wait 6 seconds
Master Finger x 1
If you make any mistake or you just simply want to exit Quick Programming, wait for the meout of 10 seconds.
With this, the quick programming is completed. The system is now opera onal with default value for Door Open Time of 3
seconds.
For more comprehensive programming, refer to the “DINB100-SA Programming” sec on.
Important:
When using proximity reader for Finger Or/and Card Mode, first present the Card then swipe the finger min. 6 mes.
When using keypad for Finger Or/And Pin Code mode first enter the PIN Code, then swipe the finger min. 6 mes.
When using mifare card reader for Finger On Card Mode first swipe the finger min. 6 mes, then present a Card.
For Fast Dele ng a user in Finger On Card mode swipe the Master or Admin finger then present an exis ng user card
9.0 KEEP THE DOOR UNLOCKED
Swipe ANY enrolled finger twice and the Door will stay unlocked, un l valid finger is swiped.
While the door is unlocked the tricolor indica on LED stays green.
www.visual-plus.com
7
User Finger x 2
10.0 DINB100-SA PROGRAMMING MENU
10.1 Adding Users
Swipe the Master/Admin finger 5 mes un l the light pa ern on figure.9 is shown
BL
Figure.9
x 5
Tap sensor
BL
BL
BL
BL
BL
Select User Group
Swipe the finger to select:
Group 1
Group 2
Group 3
Group 4
BL
BL
BL
BL
Group 5
Group 6
Group 7
Group 8
Tap sensor
BL
BL
Assign Relay Output
Swipe the finger to select:
Relay 1
Relay 2
BL
BL
Both
None
NOTE:
Swipe UPWARDS to exit the MENU
Tap sensor
(Orange Blinking)
Swipe the user finger for Finger mode min.6 mes.
When using proximity reader for Finger Or/and Card Mode, first present the Card then swipe the finger min. 6 mes.
When using keypad for Finger Or/And Pin Code mode first enter the PIN Code, then swipe the finger min. 6 mes.
www.visual-plus.com
8
10.0 DINB100-SA PROGRAMMING MENU
10.2 Delete User
Swipe the Master/Admin finger 7 mes un l the light pa ern on figure.12 is shown
Figure.12
x 7
Tap sensor
Blinking row >
Swipe finger or present Card or enter PIN
NOTE:
Swipe UPWARDS to exit the MENU
10.3 Delete All Users
OK Beep
Back to MAIN MENU
Swipe the Master/Admin finger 11 mes un l the light pa ern on figure.14 is shown
Figure.14
x 11
Tap sensor
NOTE:
Swipe UPWARDS to exit the MENU www.visual-plus.com
Blinking row >
Tap sensor
to confirm or swipe UP to Cance
l
OK Beep
9
deleting...
Note: The Master and the Administrators will not be deleted
Back to MAIN MENU
10.0 DINB100-SA PROGRAMMING MENU
10.4 Delete Group of Users
Swipe the Master/Admin finger 6 mes un l the light pa ern on figure.13 is shown
Figure.13
x 6
Tap sensor
BL
BL
BL
BL
Select User Group to Delete
Swipe the finger to select:
Group 1
Group 2
Group 3
Group 4
BL
BL
BL
BL
Group 5
Group 6
Group 7
Group 8
Tap sensor
OK Beep
Back to MAIN MENU
NOTE:
Swipe UPWARDS to exit the MENU
Note: All fingers that are enrolled in the Group will be deleted.
www.visual-plus.com
10
10.0 DINB100-SA PROGRAMMING MENU
10.5 Add Administrator
Swipe the Master/Admin finger 12 mes un l the light pa ern on figure.10 is shown
BL
Figure.10
x 12
Tap sensor
BL
BL
Select Admin nr.
Scroll down to select:
Admin 1
Admin 2
Tap sensor
(Orange Blinking)
Swipe the Admin finger min.6 mes.(Un l Ok beep) x 6
Note: If keypad is connected, enter the User Pin Code , then swipe the user finger min.6 mes(Un l Ok Beep).
Back to MAIN MENU
(to Add User menu)
NOTE:
Swipe UPWARDS to exit the MENU
- There is 1 Master Finger. The master finger can enroll/delete user and all the other se ngs.
- The Master finger can be changed ONLY with the jumper.
- There are 2 Aministrator Fingers. The administrator can do all the things that Master can do. The Master can delete the
Administrator, but the Administrator can not delete the Master.
www.visual-plus.com
11
10.0 DINB100-SA PROGRAMMING MENU
10.6 Delete Administrator
Swipe the Master/Admin finger 13 mes un l the light pa ern on figure.11 is shown
BL
Figure.11
x 13
Tap sensor
BL
BL
Select Admin nr.
Scroll down to select:
Admin 1
Admin 2
Tap sensor deleting..
OK Beep
NOTE:
Swipe UPWARDS to exit the MENU
Back to MAIN MENU
- There is 1 Master Finger. The master finger can enroll/delete user and all the other se ngs.
- The Master finger can be changed ONLY with the jumper.
- There are 2 Aministrator Fingers. The administrator can do all the things that Master can do. The Master can delete the
Administrator, but the Administrator can not delete the Master.
www.visual-plus.com
12
10.0 DINB100-SA PROGRAMMING MENU
10.7 Se ngs
Swipe the Master/Admin finger 10 mes un l the light pa ern on figure.7 is shown
Figure.7
x 10
Tap sensor
Blinking row >
BL
BL
BL
By swiping finger select appropriate light pa ern
Swipe the finger to select:
Sensor sensitivity
BL
Sensor security
BL
Entry mode
BL
BL
Remote Relay
Touch Function
Buzzer
Backlight
Reserved
Tap sensor
Continues on the next 2 pages
go to next page
NOTE:
Swipe UPWARDS to exit the MENU
Entry Mode - used when addi onal proximity or keypad reader is connected
Remote Relay Touch Func on - Enabling/Disabling the Touch Bu on Func on in the remote relay Unit
Buzzer - Enabling/Disabling the Buzzer
Backlight - Enabling/Disabling the Backlight www.visual-plus.com
13
10.0 DINB100-SA PROGRAMMING MENU
10.7 Se ngs
10.7.1 Entry Mode and Backlight
Entry MODE
Tap sensor
BL
BL
BL
BL
By swiping finger select entry mode
Finger
Scroll down to select:
Finger AND Card
BL
Finger OR PIN
Finger ON Card
BL
Finger AND PIN
Finger OR Card
Tap sensor
Backlight
Tap sensor
Backlight ON/OFF
Scroll down to select:
Remote OFF
Reader OFF
All ON
All OFF
Tap sensor
OK Beep
OK Beep
Back to MAIN MENU
Back to MAIN MENU
NOTE:
Swipe UPWARDS to exit the MENU www.visual-plus.com
14
10.0 DINB100-SA PROGRAMMING MENU
10.7 Se ngs
10.7.2 Buzzer Sound and Remote Relay Touch Func on
Buzzer sound
Tap sensor
Buzzer ON/OFF
Scroll down to select:
Remote OFF
Reader OFF
All ON
All OFF
Tap sensor
Remote Relay Touch Function
Tap sensor
Touch Button ON/OFF
Scroll down to select:
1 ON
2 OFF
Tap sensor
OK Beep OK Beep
Back to MAIN MENU Back to MAIN MENU
NOTE:
Swipe UPWARDS to exit the MENU www.visual-plus.com
15
10.0 DINB100-SA PROGRAMMING MENU
10.8 Set Door Relay Time
Relay1 time
(for Relay1 in DINB100-SA, RTT and DINRTT )
Swipe the Master/Admin
finger 8 times x 8
Tap sensor
Blinking row >
BL
BL
BL
BL
Select relay open time
Scroll down to select:
1 sec
3 sec
5 sec
10 sec
BL
BL
BL
BL
20 sec
30 sec
60 sec
Toggle
Tap sensor
Relay2 time
(for Relay 2 in DINRTT Remote Relay Unit)
Swipe the Master/Admin
finger 9 mes x 9
Tap sensor
Blinking row >
BL
BL
BL
BL
Select relay open time
Scroll down to select:
1 sec
3 sec
5 sec
10 sec
BL
BL
BL
BL
20 sec
30 sec
60 sec
Toggle
Tap sensor
OK Beep OK Beep
Back to MAIN MENU Back to MAIN MENU
NOTE:
Swipe UPWARDS to exit the MENU www.visual-plus.com
16
10.0 DINB100-SA PROGRAMMING MENU
10.9 Adding Users In Finger On Card Mode (when Mifare Reader is connected)
Swipe the Master/Admin finger 5 mes un l the light pa ern on figure.9 is shown
BL
Figure.9
x 5
BL
BL
Tap sensor
BL
Group 1
Group 2
BL
BL
Select User Group
Swipe the finger to select:
Group 3
Group 4
BL
BL
Group 5
Group 6
BL
BL
Tap sensor
Group 7
Group 8
NOTE:
Swipe UPWARDS to exit the MENU
BL
BL
Assign Relay Output
Swipe the finger to select:
Relay 1
Relay 2
BL
BL
Both
None
Tap sensor
(Orange Blinking)
Swipe the user finger min.6 mes (Un l Ok beep).
The backlight starts to blink green and the buzzer beeps.
x 6
Present the Card and hold it in the proximity field un l OK beep, which is indica on that the finger enrolled is wri en in the card.
In Finger on Card” mode, the fingerprint is stored only into the Mifare card (Mifare Classic 1K/4K or DesFire) and not in the reader. The matching is done by first presenting the card, then swiping the finger. According to this, the system in “finger on Card” mode does not have capacity limit. Furthermore, the fingerprint is not stored in the reader’s memory, which disables any misuse of the stored fingerprint templates
www.visual-plus.com
17
11.0 PROGRAMING DINB100-SA WITH KEYPAD
11.1 Adding Users
Swipe Master/Admin finger or enter Admin PIN.
The Biometric reader starts to blink.
BL
BL
1.
Press 1
2.
Enter user loca on number 01 to 97
3.
Assign relay. Press 1 for Relay1 or 2 for Relay2
4.
Assign user group 1 to 8.(Press 1 for group 1...)
5.
Press A to confirm
BL BL
6.
Enter user PIN code. (1 to 8 digits)
7.
Press A to confirm
Swipe the User finger min.6 mes.(Un l Ok Beep) x 6
Op onal
To Enroll again go to step 1.
To Exit press 0, A
7
A
1
4
2
5
8
0
9
B
3
6
www.visual-plus.com
18
11.0 PROGRAMING DINB100-SA WITH KEYPAD
11.2 Delete User By User Loca on Number
Swipe Master/Admin finger or enter Admin PIN.
The Biometric reader starts to blink.
BL
BL
1.
Press 7.
2.
Enter user loca on number, 01 to 97.
3.
Press A to confirm.
To Exit press 0, A
11.3 Delete User Group
Swipe Master/Admin finger or enter Admin PIN.
The Biometric reader starts to blink.
BL
BL
1.
Press 8.
2.
Enter group number, 0 to 8.
3.
Press A to confirm.
To Exit press 0, A
Note: All fingers that are enrolled in the Group will be deleted.
www.visual-plus.com
19
7
A
1
4
2
5
8
0
9
B
3
6
11.0 PROGRAMING DINB100-SA WITH KEYPAD
11.4 Delete All Users
Swipe Master/Admin finger or enter Admin PIN.
The Biometric reader starts to blink.
BL BL
1.
Press 9.
2.
Press 5,1,3,5,7.
3.
Press A to confirm.
To Exit press 0, A
11.5 Delete User by User Finger
Swipe Master/Admin finger or enter Admin PIN.
The Biometric reader starts to blink.
BL
BL
1.
Press 6.
2.
Press A.
3.
Enter user PIN then press A or swipe the user finger.
To Exit press 0, A
www.visual-plus.com
20
7
A
1
4
2
5
8
0
9
B
3
6
11.0 PROGRAMING DINB100-SA WITH KEYPAD
11.6 Set Door Relay Time
Swipe Master/Admin finger or enter Admin PIN.
The Biometric reader starts to blink.
BL BL
1.
Press 2.
2.
Press 1 or 2 to select Relay1 or Relay2
3.
Select the me code from the Table1.
Table1.
Time Codes
1
2
3
4
5
6
7
8
Time Mode
1 sec
3 sec
5 sec
10 sec
20 sec
30 sec
60 sec
Toggle
4.
Press A to confirm.
To Exit press 0, A
7
A
1
4
2
5
8
0
9
B
3
6
www.visual-plus.com
21
11.0 PROGRAMING DINB100-SA WITH KEYPAD
11.7 Buzzer Se ngs
7
A
1
4
2
5
8
0
9
B
3
6
1.
Press 3,1.
2.
Select the Buzzer Code from the Table2.
Table2.
Buzzer Code
1
2
3
4
Buzzer Mode
Remote OFF
Reader OFF
All ON
All OFF
4.
Press A to confirm.
To Exit press 0, A
Note 1: When “Remote OFF” is selected, the buzzer is OFF in the remote relay unit. In the biometric reader and in the keypad the buzzer is ON.
Note 2: When “Reader OFF” is selected, the buzzer is ON in the remote relay unit. In the biometric reader and in the keypad the buzzer is OFF.
www.visual-plus.com
22
11.0 PROGRAMING DINB100-SA WITH KEYPAD
11.8 Backlight Se ngs
1.
Press 3,2.
2.
Select the Backlight Code from the Table3.
Table 3.
Backlight Code
1
2
3
4
Backlight Mode
Remote OFF
Reader OFF
All ON
All OFF
4.
Press A to confirm.
To Exit press 0, A
Note 1: When “Remote OFF” is selected, the backlight is OFF in the remote relay unit. In the biometric reader and in the keypad the backlight is ON.
Note 2: When “Reader OFF” is selected, the backlight is ON in the remote relay unit. In the biometric reader and in the keypad the backlight is OFF.
www.visual-plus.com
23
7
A
1
4
2
5
8
0
9
B
3
6
11.0 PROGRAMING DINB100-SA WITH KEYPAD
11.9 Set the Touch Bu on Func on
1.
Press 3,3.
2.
Select the Touch Code from the Table 4.
Table 4.
Touch Code Touch Mode
1
2
Touch ON
Touch OFF
4.
Press A to confirm.
To Exit press 0, A
Remote Relay Touch Func on - Enabling/Disabling the Touch Bu on Func on in the remote relay Unit
11.10 Unpair Remote Relay
7
A
1
4
2
5
8
0
9
B
3
6
www.visual-plus.com
1.
Press 3,5.
2.
Press 7,1,5,9.
3.
Pres A to confirm
To Exit press 0, A
24
11.0 PROGRAMING DINB100-SA WITH KEYPAD
11.11 Entry Mode Se ngs
1.
Press 3,4.
3.
Select the me code from the Table 5.
Table 5.
Entry Codes
1
2
3
4
5
6
Entry Mode
Finger
Finger or Card
Finger and Card
Finger or PIN
Finger and PIN
Finger ON Card
4.
Press A to confirm.
To Exit press 0, A
7
A
1
4
2
5
8
0
9
B
3
6
www.visual-plus.com
25
11.0 PROGRAMING DINB100-SA WITH KEYPAD
11.12 Add Administrator
7
A
1
4
2
5
8
0
9
B
3
6
3.
4.
1.
2.
5.
Press 4,1.
Press 1 or 2 to select Admin1 or Admin2
Press A to confirm.
Enter Admin PIN code.( 1 to max 8 numbers)
Press A to confirm
Swipe the Admin finger min.6 mes.(Un l Ok Beep) x 6
To Exit press 0, A
- There is 1 Master Finger. The master finger can enroll/delete user and all the other se ngs.
- The Master finger can be changed ONLY with the jumper.
- There are 2 Aministrator Fingers. The administrator can do all the things that Master can do. The Master can delete the Administrator, but the Administrator can not delete the Master.
11.13 Delete Administrator
www.visual-plus.com
1.
Press 4,0.
2.
Press 1 or 2 to select Admin1 or Admin2
3.
Press A to confirm.
To Exit press 0, A
26
This product herewith complies with requirements of EMC directive 2014/30/EU. In addition it complies with
RoHS directive EN50581:2012
Visual Plus Corporation, s.a.
Drève Richelle 161
WOP G - Bte 34
1410 Waterloo - Belgium
www.visual-plus.com
27
a Visual Plus Corporation
Company
www.visual-plus.com
28

Public link updated
The public link to your chat has been updated.
Advertisement
Key features
- Standalone Biometric Access Control System
- Stores up to 97 Fingerprint Templates
- One Relay Output
- One Exit Button Input
- Remote Relay Unit Support
- Fingerprint Verification for Access Control
- One-Door Applications