P1500E CB report sk
Page 3 of 10
Report No. 11030247 003
List of Attachments (including a total number of pages in each attachment):
- Photo documentation
- National Differences
Total number of pages in each attachment is indicated in individual attachment.
Summary of testing:
Tests performed (name of test and test clause):
Testing location:
All applicable tests as described in Test Case and
Measurement Sections were performed.
All tests as described in Test Case and
Measurement Sections were performed at the
laboratory described on cover page.
•
•
•
The maximum operating ambient shown in
user’s manual is 40°C.
The load conditions used during testing as
below:
- video signal provided
- full raster
- maximum brightness and contrast
- continuous operation
- maximum volume for speaker
Test samples are pre-production samples
without serial numbers.
Summary of compliance with National Differences
List of countries addressed:
EU Group Differences, EU Special National Conditions, CA, DE, IL, FI, KR, US.
Explanation of used codes: CA = Canada, DE = Germany, FI = Finland, IL = Israel, KR = Republic of
Korea, US = United States.
The product fulfils the requirements of A11:2009, A1:2010 and A12:2011 of EN 60950-1:2006.
Copy of marking plate
N/A.
TRF No. IEC60950_1C
Page 4 of 10
Report No. 11030247 003
Test item particulars...................................................:
Equipment mobility.....................................................: [X] movable [] hand-held
[] transportable
[X] stationary [] for building-in [] direct plug-in
Connection to the mains ............................................: [X] pluggable equipment [X] type A [] type B
[] permanent connection
[X] detachable power supply cord
[] non-detachable power supply cord
[] not directly connected to the mains
Operating condition ....................................................: [X] continuous
[] rated operating / resting time:
Access location .........................................................: [X] operator accessible
[] restricted access location
Over voltage category (OVC) ...................................: [] OVC I
[] other:
[X] OVC II
[] OVC III
[] OVC IV
Mains supply tolerance (%) or absolute mains supply
values ........................................................................: +10%, -10%
Tested for IT power systems ....................................: [X] Yes
[] No
IT testing, phase-phase voltage (V) ..........................: 230
Class of equipment ...................................................: [X] Class I [] Class II
[] Not classified
[] Class III
Considered current rating of protective device as
20
part of the building installation (A) ............................:
Pollution degree (PD) ................................................: [] PD 1
[X] PD 2
[] PD 3
IP protection class .....................................................: IPX0
Altitude during operation (m) ....................................: Up to 3000
Altitude of test laboratory (m) ....................................: Less than 2000
Mass of equipment (kg) ............................................: 2.1
Possible test case verdicts:
- test case does not apply to the test object ................ : N/A (or N)
- test object does meet the requirement ...................... : P (Pass)
- test object does not meet the requirement ................ : F (Fail)
Testing.......................................................................... :
Date of receipt of test item ............................................ : Dec., 2013
Date(s) of performance of tests .................................... : Dec. 2013 to Jan. 2014
General remarks:
The test results presented in this report relate only to the object tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing testing
laboratory.
"(see Enclosure #)" refers to additional information appended to the report.
"(see appended table)" refers to a table appended to the report.
Throughout this report a
comma /
point is used as the decimal separator.
Manufacturer’s Declaration per sub-clause 6.2.5 of IECEE 02:
TRF No. IEC60950_1C
Page 5 of 10
Report No. 11030247 003
Yes
Not applicable
The application for obtaining a CB Test Certificate
includes more than one factory location and a
declaration from the Manufacturer stating that the
sample(s) submitted for evaluation is (are)
representative of the products from each factory has
been provided ............................................................... :
When differences exist; they shall be identified in the General product information section.
Name and address of factory (ies) .......................... : 1.
2.
Qisda Corporation
157, Shan-Ying Road, Gueishan, Taoyuan
333, Taiwan
Qisda Optronics (Suzhou) Co., Ltd.
No. 169, Zhujiang Road, New District,
Suzhou, Jiangsu 215129, P.R. China
General product information:
Description of change(s):
1. Add a main board definition as type B.
2. Add alternative source of DC Blower Fan and DC Fan (Front).
3. Upgrade Japan Deviation from J3000 (H21) to J3000 (H25).
For the above described change(s) the following was considered to be necessary:
Change
Testing
Comments
1.
•
Input test
•
LPS test
•
Connectors overload (per
client’s request)
2.
•
Heating test
Due to test results of heating are little higher than
previous and the previous test results is far from
limit therefore no other testing is considered
necessary.
See appended table for test results.
3.
•
N/A
See National Differences for evaluation.
Input test results are below previous therefore no
thermal tests are considered necessary.
See appended table for test results and photo
documentation for details.
History of amendments and modifications:
th
Ref. No. 11030247 001, dated 20 Sep, 2012 (original test report)
st
Ref. No. 11030247 002, dated 21 Feb., 2013 (modification)
th
Ref. No. 11030247 003, dated 8 Jan., 2014 (modification)
Abbreviations used in the report:
- normal conditions
- functional insulation
- double insulation
- between parts of opposite
polarity
- distance through insulation
- Ext. dcr
- Int. dcr
TRF No. IEC60950_1C
N.C.
OP
DI
- single fault conditions
- basic insulation
- supplementary insulation
BOP
- reinforced insulation
Dti
External creepage distance
Internal creepage distance
S.F.C
BI
SI
RI
Page 6 of 10
Report No. 11030247 003
IEC 60950-1
Clause
Requirement + Test
1.5.1
TABLE: List of critical components
Object/part No.
Manufacturer/
trademark
Result - Remark
Verdict
P
Type/model
Technical data
Standard (Edition
/ year)
Mark(s) of
1
conformity )
DC Blower Fan
Delta
BUB0512HD-C
12Vdc, max.
0.18A, mi.
3.34CFM,
3300RPM,
Outward.
UL, TÜV
IEC 609501:2005+A1,
EN 609501:2006+A11+A1+
A12,
UL 60950-1
DC Fan (Front)
Delta
AUB0712HH-C
12Vdc, max.
0.40A, min.
32.94CFM,
4500RPM,
Outward.
UL, TÜV
IEC 609501:2005+A1,
EN 609501:2006+A11+A1+
A12,
UL 60950-1
Supplementary information:
1) Provided evidence ensures the agreed level of compliance. See OD-CB2039.
1.6.2
U(V)/f(Hz)
TABLE: Electrical data (in normal conditions)
I (A)
P
Irated (A)
P (W)
Fuse #
Ifuse (A)
Condition/status
For main board type B
Signal input from D-sub
90/50
2.97
--
265
F601
2.97
Maximum normal load.
90/60
2.98
--
264
F601
2.98
Maximum normal load.
100/50
2.67
3.0
270
F601
2.67
Maximum normal load.
100/60
2.7
3.0
268
F601
2.7
Maximum normal load.
240/50
1.01
3.0
252
F601
1.01
Maximum normal load.
240/60
1.02
3.0
251
F601
1.02
Maximum normal load.
264/50
1.01
--
253
F601
1.01
Maximum normal load.
264/60
1.01
--
254
F601
1.01
Maximum normal load.
Signal input from Video
90/50
2.99
--
268
F601
2.99
Maximum normal load.
90/60
2.97
--
266
F601
2.97
Maximum normal load.
100/50
2.67
3.0
269
F601
2.67
Maximum normal load.
100/60
2.68
3.0
268
F601
2.68
Maximum normal load.
240/50
1.06
3.0
255
F601
1.06
Maximum normal load.
240/60
1.06
3.0
254
F601
1.06
Maximum normal load.
264/50
1.00
--
254
F601
1.00
Maximum normal load.
TRF No. IEC60950_1C
Page 7 of 10
Report No. 11030247 003
IEC 60950-1
Clause
264/60
Requirement + Test
1.01
Result - Remark
Verdict
--
253
F601
1.01
Maximum normal load.
Signal input from S-Video
90/50
2.99
--
266
F601
2.99
Maximum normal load.
90/60
2.98
--
265
F601
2.98
Maximum normal load.
100/50
2.69
3.0
269
F601
2.69
Maximum normal load.
100/60
2.68
3.0
268
F601
2.68
Maximum normal load.
240/50
1.06
3.0
255
F601
1.06
Maximum normal load.
240/60
1.06
3.0
254
F601
1.06
Maximum normal load.
264/50
1.01
--
255
F601
1.01
Maximum normal load.
264/60
1.01
--
256
F601
1.01
Maximum normal load.
Signal input from HDMI
90/50
2.99
--
268
F601
2.99
Maximum normal load.
90/60
3.00
--
267
F601
3.00
Maximum normal load.
100/50
2.70
3.0
270
F601
2.70
Maximum normal load.
100/60
2.69
3.0
269
F601
2.69
Maximum normal load.
240/50
1.09
3.0
255
F601
1.09
Maximum normal load.
240/60
1.08
3.0
255
F601
1.08
Maximum normal load.
264/50
1.08
--
256
F601
1.08
Maximum normal load.
264/60
1.06
--
256
F601
1.06
Maximum normal load.
Supplementary information:
2.5
TABLE: limited power sources
P
Circuit output tested:
Note: Measured Uoc (V) with all load circuits disconnected: See below
Components
Sample
No.
Uoc (V)
Isc (A)
VA
Meas.
Limit
Meas.
Limit
For main board type B
For Video connector
Normal (pin 1 to
earth)
1
0
0
--
0
--
1
0
0
--
0
--
For S-Video connector
Normal (pin 1-4 to
earth)
TRF No. IEC60950_1C
Page 8 of 10
Report No. 11030247 003
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
For Audio input connector
0
0
--
0
--
1
0
0
--
0
--
Normal (pin 111,13,14 to earth)
1
0
0
--
0
--
Normal (pin 12,15
to earth)
1
4.5
0.005
8
0.01
100
Normal (pin
2,3,5,8,11,13-19
to earth)
1
0
0
--
0
--
Normal (pin
1,4,6,7,9,10,12 to
earth)
1
3.3
0.079
8
0.1
100
1
0
0
--
0
--
Normal (pin
1,2,4,5 to earth)
1
0
0
--
0
--
Normal (pin 3 to
earth)
1
3.3
0.005
8
0.05
100
Normal (pin 1-2 to
earth)
1
For Audio output connector
Normal (pin 1-4 to
earth)
For D-sub connector
For HDMI connector
For RS232 connector
Normal (pin 1-9 to
earth)
For miniUSB connector
supplementary information:
Input voltage 264V/60Hz
4.5
TABLE: Thermal requirements
P
4.
5.
4.
5.
Supply voltage (V) .......................... :
90
90
264
264

Ambient Tmin (°C) ............................ :
--
--
--
--

Ambient Tmax (°C) ............................ :
See
below
See
below
See
below
See
below

Maximum measured temperature T of part/at::
Allowed
Tmax
(°C)
T (°C)
L601 of power supply
80.9
83.0
46.8
46.6
105
L603 of power supply
77.9
79.2
46.0
45.7
105
TRF No. IEC60950_1C
Page 9 of 10
Report No. 11030247 003
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
T601 of power supply
71.0
71.2
46.7
46.2
105
C619 of power supply
55.1
55.3
45.7
45.6
105
T651 coil of power supply
66.1
68.8
56.1
56.0
90
T651 core of power supply
68.7
71.3
61.1
61.1
90
IC652 of power supply
71.6
79.6
55.3
55.6
100
L3 of ballast
74.9
73.1
74.5
72.5
105
Enclosure near inlet
41.6
41.3
41.1
41.9
95
Enclosure near outlet
75.1
74.0
71.5
70.0
95
40.0/22.3
40.0/21.4
40.0/21.5
40.0/21.4
--
Tma/Tamb
Supplementary information:
1. The temperatures were measured under worst case normal mode defined in 1.2.2.1 and as described
in 1.6.2 at voltages as described in above.
2. Unit specified with maximum of 40°C ambient temperatures and above test data was calculated by
original test result of ambient temperature above.
Winding components (providing safety isolation):
- Class 105 material (A)
Tmax = 100°C - 10°C = 90°C
3. Thermocouple method used for measuring the temperatures.
4. Test for normal position.
5. Test for wall mount position.
Temperature T of winding:
t1 (°C)
R1 (Ω)
t2 (°C)
R2 (Ω)
T (°C)
Allowed
Tmax (°C)
Insulatio
n class
Supplementary information:
5.3
Component
No.
TABLE: Fault condition tests
P
Ambient temperature (°C) ....................................:
25, if no otherwise specified

Power source for EUT: Manufacturer, model/type,
output rating .........................................................:
See appended table 1.5.1

Fault
Supply
voltage
(V)
Test
time
Fuse #
Fuse
current
(A)
Observation
For main board type B
Video
connector
pin 1
over-load
240
10 min
F601
1.1
Open circuit voltage: 0V. Unit
operated normally, no damage,
no hazards.
S-Video
connector
pin 1,2,3,4
over-load
240
10 min
F601
1.1
Open circuit voltage: 0V. Unit
operated normally, no damage,
no hazards.
TRF No. IEC60950_1C
Page 10 of 10
Report No. 11030247 003
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
Audio input
connector
pin 1,2
over-load
240
10 min
F601
1.1
Open circuit voltage: 0V. Unit
operated normally, no damage,
no hazards.
Audio
output
connector
pin 1,2
over-load
240
10 min
F601
1.1
Open circuit voltage: 0V. Unit
operated normally, no damage,
no hazards.
D-sub input
connector
pin 1-11,
13, 14
over-load
240
10 min
F601
1.1
Open circuit voltage: 0V. Unit
operated normally, no damage,
no hazards.
D-sub input
connector
pin 12,15
over-load
240
10 min
F601
1.1
Open circuit voltage: 4.5V, load to
4.5mA maximum. Unit operated
normally, no damage, no
hazards.
HDMI
connector
pin 2, 3, 5,
8, 11, 13-19
over-load
240
10 min
F601
1.1
Open circuit voltage: 0V. Unit
operated normally, no damage,
no hazards.
HDMI
connector
pin 1, 4, 6,
7, 9, 10, 12
over-load
240
8 hr
F601
1.1
Open circuit voltage: 3.3V, load to
79mA maximum. Unit operated
normally, no damage, no
hazards.
mini USB
connector
pin 1,2,4,5
over-load
240
10 min
F601
1.1
Open circuit voltage: 0V. Unit
operated normally, no damage,
no hazards.
mini USB
connector
pin 3
over-load
240
10 min
F601
1.1
Open circuit voltage: 3.3V, load to
4.5mA maximum. Unit operated
normally, no damage, no
hazards.
RS232
connector
pin 1-9
over-load
240
10 min
F601
1.1
Open circuit voltage: 0V. Unit
operated normally, no damage,
no hazards.
Supplementary information:
TRF No. IEC60950_1C
Page 1 of 2
Report No.: 11030247 003
J3000 (H25)
Clause
Requirement + Test
Appendix
Appendix 12 J3000 (H25)
Special National conditions, National deviation and other information according to
MITI Ordinance No. 85.

1
General requirement
When equipment provides with appliance inlet
complying with JIS C 8283-1(2008), soldered
parts of appliance inlet is not applied by force
during insert or removal of connector.
This is not applied when inlet body is fixed itself
and not fixed by solder.
P
2
Requirement for equipment
2.1
Heater Appliances
When diode is used in parallel at the power
sources for adjustment of power consumption,
the equipment shall remain safe for operation
under open condition of one diode.
N/A
The current rating of one diode shall be more
than main current. The diodes connected in
parallel are same type.
N/A
The heating test specified by clause 11 of JIS C
9335-1(2003) and a specified in applicable
indivisual requirements under open condition of
one diode of parallel shall comply with the
requirements.
N/A
2.2
Electric heater with glowing heating elements
Result - Remark
Inlet is fixed by adequate
mechanical construction, not rely
on soldering.
Verdict

Not electric stove.
N/A
Surface treatment by paint or adhesive on
protective frame or protective mesh shall not be
used.
N/A
Caution marking like below shall be on
- easily visible place of the equipment or
- Instruction manual
N/A
「注意 当該機器から、使用初期段階で揮発性有機化合
物及びカルボニル化合物が最も放散するおそれがあるた
め、その際には十分換気を行うこと。」
3
Components used in equipment
3.1
Motor capacitors used in ventilating fan, electric
fan, air conditioner, electric washing machine,
refrigerator or electric freezer shall be comply
with
- capacitors with protective elements or
protective mechanism complying with JIS C
4908(2007)
- P2 capacitor complying with IEC 602521(2001)
Capacitor complying with below is acceptable
J3000 (H25)
No relevant equipment or
component.
N/A
N/A
Page 2 of 2
Report No.: 11030247 003
J3000 (H25)
Clause
3.2
J3000 (H25)
Requirement + Test
Result - Remark
Verdict
Enclosed by metal or ceramic
N/A
No non-metallic materials within 50 mm from
capacitor surface
N/A
Non-metallic material within 50mm from capacitor
surface comply with needle frame test of JIS C
9335-1(2003), Annex E
N/A
Non-metallic material within 50 mm from
capacitor surface comply with V-1 test of JIS C
60965-11-10(2006).
N/A
Plug directly inserted to outlet used refrigerator or
electric freezer.
Shall comply with
- Face contact with outlet shall have CTI with
more than 400 according to JIS C
2134(2007) or
- Supporting material of blades shall comply
with glow wire test by temperature of 750ºC
according to JIS C 60695-2-11(2004) or JIS
C 60695-2-12(2004).
Materials having glow wire frame
temperature of 775 ºC are acceptable.
N/A
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project