American Standard 7005101.002 Copeland® 1.5 gpm 1-Hole Monoblock Bathroom Faucet Installation Manual
Add to My manuals6 Pages
American Standard 7005101.002 is a monobloc lavatory faucet with a Speed Connect drain, designed for easy installation and reliable performance. Its unique Speed Connect drain system features fewer parts and installs quickly, eliminating the need for adjustment and ensuring a proper seal every time. The faucet is certified to comply with ANSI A112.18.1 standards and is compatible only with the Speed Connect drain. It comes with a mounting nut, gasket, retaining washer, mounting stud, faucet supplies, and drain cable assembly for a complete installation.
advertisement
Installation
Instructions
COPELAND™
7005.101
MONOBLOCK LAVATORY
FAUCET with Speed Connect™ Drain
Series
Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found only on American Standard faucets.
Speed Connect Drain*
• Fewer parts, installs in less time
• Never needs adjustment
• Guaranteed to seal properly the first time, every time.
Certified to comply with ANSI A112.18.1
*Your new American Standard faucet is designed to work only with the Speed Connect drain.
To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin.
M965073 REV.1.3
Recommended tools
Screwdriver Channel Locks Adjustable Wrench
1
INSTALL FAUCET
CAUTION
Turn off hot and cold water supplies before beginning.
Installation with ESCUTCHEON PLATE: Apply a light bead of plumbers putty to underside of ESCUTCHEON PLATE (9) if mounting surface is uneven.
Place ESCUTCHEON
PLATE (9) onto sink or mounting surface.
Feed FAUCET SUPPLIES (3) , MOUNTING
STUD (4) and DRAIN CABLE ASSEMBLY (8) through ESCUTCHEON PLATE and PUTTY
PLATE (9) and mounting hole of lavatory or mounting surface.
Fig. A.
Installation less ESCUTCHEON PLATE:
Seat SEAL (1) into under side of FAUCET BASE (2) .
Feed FAUCET SUPPLIES (3) , MOUNTING STUD (4) and DRAIN
CABLE ASSEMBLY (8) through the mounting hole of lavatory or mounting surface. Fig. B.
Fig.
A.
COLLAR ON
MOUNTING NUT
7
5
6
4
Fig.
C.
1
3
Fig.
B.
9
2
GROOVE
(FAUCET
BASE)
4
PUTTY
IF REQUIRED
MOUNTING SURFACE
From below, push GASKET (7) and RETAINING WASHER (5) onto
MOUNTING STUD (4) . Secure Faucet with MOUNTING NUT (6) , pulling faucet to front of sink, so SUPPLIES (3) rests against mounting hole. Before final tightening, make sure collar on
MOUNTING NUT (6) is seated into RETAINING WASHER (5) .
Fig. C .
Adjust Faucet so that it is centered. Tighten MOUNTING NUT (6) to complete faucet mounting.
1
8
2
POP-UP DRAIN
Remove CLEAR PLASTIC COVER (1) .
Remove CARDBOARD SPACER (2) from under
DRAIN POP-UP (3) .
Tighten TAILPIECE (4) on DRAIN BODY before installing DRAIN BODY. Fig.
B.
Fig.
A.
1
3
2
3
REMOVE FLANGE
Thread FLANGE (1) counter-clockwise and remove
FLANGE (1) and FOAM GASKET (2) from drain body. Fig.
A.
Thread LOCKNUT (3) clock-wise to bottom of drain body. Push GASKET (4) down against
LOCKNUT (3). Fig.
B.
Fig.
A.
1
2
4
3
Fig.
B.
Fig.
B.
DRAIN
BODY
4
4
INSTALL DRAIN FROM
BELOW FIXTURE
From under side of SINK install DRAIN BODY (1) up through drain outlet.
Note: No plumber’s putty or caulk is required.
The CABLE ATTACHMENT
POINT (2) must face towards the rear of the SINK.
Install FOAM GASKET (3) and
FLANGE (4) onto drain body from above SINK and tighten
FLANGE (4) firmly.
4
3
DRAIN
OUTLET
REAR
OF SINK
1
2
5
TIGHTEN LOCKNUT
Tighten LOCKNUT (1) firmly with Adjustable
Wrench or Channel Locks.
6
FLANGE GASKET AND POP-UP KNOB
Check DRAIN FLANGE in SINK to ensure that
WHITE FOAM GASKET (3) is fully compressed and not visible. Fig.
A.
POP-UP KNOB (1) must be fully down. Fig.
B.
Fig.
A.
WHITE FOAM
GASKET
NOT VISIBLE
DRAIN
FLANGE
Fig.
B.
1
DOWN
1
M965073 REV.1.3
2
7
ATTACH CABLE CONNECTOR
Thread CABLE CONNECTOR (1) clockwise onto DRAIN BODY CONNECTION (2) and hand tighten. Fig.
A.
Your new POP-UP DRAIN installation is now complete. Fig.
B.
Note: Tailpeice on pop-up drain is 1-1/4” O.D.
Fig.
B.
Fig.
A.
1
Fig.
B.
2
1-1/4” O.D.
8
CHECK OPERATION OF POP-UP
Operate LIFT KNOB (1) to verify that STOPPER (2) opens and closes.
Note: If STOPPER (2) does not open and close properly then refer to the “troubleshooting section” of these instructions.
1
2
9
MAKE WATER SUPPLY AND WASTE CONNECTIONS
Connect FLEXIBLE SUPPLIES (1, 2) directly to wall supplies.
Connection on fitting supplies are 3/8" compression. Connect left SUPPLY (1) to Hot (Marked with a Red Band) and right supply to COLD (2) wall supply.
Faucet supplies are 20" long from faucet base.
Note: If additional supply length is required, installer must purchase additional parts separately.
Important: If SUPPLY HOSES (1, 2) are to long, loop as illustrated to avoid kinking.
Connect 1-1/4” O.D. tailpiece on POP-UP DRAIN to waste outlet.
APPROX. 20 "
1
HOT
RED
BAND
2
BLUE
BAND
3/8" COMPRESSION
COLD
M965073 REV.1.3
3
10
TEST INSTALLED FITTING
With HANDLE (1) in OFF position, turn on WATER
SUPPLIES (2) and check all connections for leaks.
Remove AERATOR (3) .
Operate HANDLE (1) to flush water lines thoroughly.
Replace AERATOR (3) .
CHECK DRAIN CONNECTIONS
Operate POP-UP KNOB (4) and fill lavatory with water.
Check that DRAIN STOPPER (5) makes a good seal and retains water in SINK. If DRAIN STOPPER (5) does not seal properly, please refer to Troubleshooting section in these instructions.
Release POP-UP KNOB (4) down and check all drain connections and "P" trap for leaks. Tighten if necessary.
4
2
11
SERVICE CAUTION Turn off hot and cold water supplies before beginning.
To remove or replace cartidge: Fig.
A.
Turn valve to OFF position.
Remove HANDLE SCREW (2) .
Pull off HANDLE (3) and CAP (4) .
Unthread CARTRIDGE NUT (5) and remove.
Pull out CARTEIDGE (6) .
Inspect CARTRIDGE (6) and O-RING (7) for debris and clean if necessary.
Clean MANIFOLD (8) and rinse clean.
Reinstall CARTRIDGE (6) and O-RING (7) onto MANIFLOD (8) .
Reinstall CARTRIDGE NUT (5) , CAP (4) and HANDLE ASSEMBLY (3) .
If spout drips, operate handle several times from OFF to ON and HOT to
COLD position. Do not force - handles turn only 90˚.
REMOVE
8
WASTE
OUTLET
1
ON
HOT
OFF
COLD
5
“P” TRAP
2
INDEX
2.5mm HEX KEY
INSTALL
4
5
6
7
3
12
CARE INSTRUCTIONS:
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
M965073 REV.1.3
4
Speed Connect™ Drain
Troubleshooting Guide
If sink does not hold water even though Stopper is in the “down” position:
• Follow CABLE ADJUSTMENT PROCEDURE.
If Stopper does not raise up fully or sink drains too slowly:
• Follow CABLE ADJUSTMENT PROCEDURE.
If you need to remove the Stopper:
• Follow STOPPER REMOVAL PROCEDURE.
If you would like the ability to remove your Stopper simply by lifting it out of the drain:
• Follow STOPPER INSTALLATION PROCEDURE for “Unlocked” mode .
CABLE ADJUSTMENT PROCEDURE
Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig.
A.
Look at the area on the Drain Body where the Cable was attached and locate the component labeled as
“Cam” in the illustration. Fig.
B.
Use a small screwdriver to rotate the Cam in the clockwise direction as far as it will go. At this point the
Stopper should be in the UP position. Fig.
B, C.
Push DOWN on the Lift-Knob to make sure it is fully down. Fig.
C.
Re-attach the Cable to the Drain Body Connection (2) by threading the Cable Connector (1) clockwise onto the
Drain Body Connection (2) and hand-tighten. Fig.
A.
Fig.
A.
Fig.
B.
Fig.
C.
DOWN
1
RE-ATTACH
CAM
1
CAM CAP
DISCONNECT
2
STOPPER
STOPPER REMOVAL PROCEDURE
Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig.
A.
Look at the area on the Drain Body where the Cable was attached and locate the component labeled as “Cam” and “Cam Cap” in the illustration. Fig.
B.
Use fingers or small screwdriver under either side of the Cam Cap to pry it out from the Drain. Fig.
D.
Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal. Fig.
E.
The Stopper can now be removed by lifting it out of the Drain. Fig.
F.
Fig.
D.
Fig.
E.
REMOVE
CAM
Fig.
F.
REMOVE
CAM CAP
M965073 REV.1.3
5
STOPPER INSTALLATION PROCEDURE
The Stopper can be installed two ways, “Locked” Mode (Stopper cannot be removed) or “Unlock” Mode (Stopper is removable).
Locked Mode:
Look at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper. Fig.
G.
To install the stopper in “Locked” mode, insert the Stopper into the Drain so that the Plastic Loop is facing toward the rear of the
Sink and the American Standard logo is facing front . Rotate
Stopper slightly if necessary so that the Stopper slides all the way down.
Fig.
G.
Re-install the Cam into the Drain, rotating the Cam if necessary to make sure it is fully inserted. Fig.
J.
Re-install the Cam Cap, making sure the guide teeth are facing outward. If the Cam Cap does not “snap” into place, then rotate the Cam to make sure it is fully inserted. Fig.
K.
Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in
Troubling Shooting Guide to complete installation. Stopper will be in “Locked” mode and not be removable.
LOGO
LOOP TOWARD
REAR OF SINK
DRAIN
Locked Mode
(Vandal Proof)
Fig.
G.
Unlocked Mode:
Look at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper. Fig.
H.
To install the stopper in “Unlocked” mode, insert the Stopper into the Drain so that the Plastic Loop is facing toward the front of the
Sink and the American Standard logo is facing rear . Rotate Stopper slightly if necessary so that the Stopper slides all the way down.
Fig.
H.
Re-install the Cam into the Drain, rotating the Cam if necessary to make sure it is fully inserted. Fig.
J.
Re-install the Cam Cap, making sure the guide teeth are facing outward. If the Cam Cap does not “snap” into place, then rotate the Cam to make sure it is fully inserted. Fig.
K.
Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in
“Troublingshooting Guide” to complete installation. Stopper will be in “Unlocked” mode and removable .
LOGO
180˚
Fig.
LOOP TOWARD
FRONT OF SINK
DRAIN
Unlocked Mode
H.
Fig.
J.
INSTALL CAM
CAM
Fig.
K.
INSTALL
CAM CAP
M965073 REV.1.3
6
advertisement