Options
Indoor unit
No.
1
2
3
4
Item
5-room centralised controller
Wiring adaptor for time clock/remote controller
(Normal open pulse contact/normal open contact)
Titanium apatite photocatalytic air-purifying filter
Remote controller loss prevention with chain
*
* 2
*
1
3
FTK(X)S25/35E
KAF970A46
Note: *1. A wiring adaptor (KRP413AB1S) is also required for each indoor unit.
*2. The time clock and other devices should be obtained locally.
*3. The filter is a standard accessory. It should be replaced approximately every 3 years.
KRC72
KRP413AB1S
KKF917A4
FTK(X)S50/60/71F
KAF952B42
5-room centralised controller
KRC72
Titanium apatite photocatalytic air-purifying filter
KAF970A46
Outdoor unit
No.
Item
1
2
Air direction adjustment grille
Drain plug
Note: *1. One set includes 5 pieces for 5 units.
Titanium apatite photocatalytic air-purifying filter
KAF952B42
Remote controller loss prevention with chain
KKF917A4
RK(X)S25/35EB
KPW937A4
RKS50/60/71F, RXS50/60F
KPW945A4
KKP937A4* 1
RXS71F
KKP945A4
Air direction adjustment grille
KPW945A4
Drain plug
KKP937A4
Control system
No.
1
2
3
4
Central remote controller
Unified On/Off controller
Schedule timer
Item
Interface adaptor for DIII-NET use
*
*
*
1
1
1
FTK(X)S25/35E
Note: *1. Interface adaptor for DIII-NET use (KRP928BB2S) is also required for each indoor unit.
DCS302CA61
DCS301BA61
DST301BA61
KRP928BB2S
FTK(X)S50/60/71F
Central remote controller
DCS302CA61
Unified On/Off controller
DCS301BA61
Schedule timer
DST301BA61
Warning
Daikin products are manufactured for export to numerous countries throughout the world. Prior to purchase, please confirm with your local authorised importer, distributor and/or retailer whether this product conforms to the applicable standards, and is suitable for use, in the region where the product will be used. This statement does not purport to exclude, restrict or modify the application of any local legislation.
Ask a qualified installer or contractor to install this product. Do not try to install the product yourself.
Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.
Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or contractor to install those parts and accessories. Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion.
Read the User’s Manual carefully before using this product. The User’s Manual provides important safety instructions and warnings. Be sure to follow these instructions and warnings.
If you have any enquiries, please contact your local importer, distributor and/or retailer.
Specifications are subject to change.
Cautions on product corrosion
1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.
2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install
the outdoor unit close to the sea shore, contact your local distributor.
JMI-0107
Organization:
DAIKIN INDUSTRIES, LTD.
AIR CONDITIONING MANUFACTURING DIVISION
Scope of Registration:
THE DESIGN/DEVELOPMENT AND MANUFACTURE OF
COMMERCIAL AIR CONDITIONING, HEATING, COOLING,
REFRIGERATING EQUIPMENT, HEATING EQUIPMENT,
RESIDENTIAL AIR CONDITIONING EQUIPMENT, HEAT
RECLAIM VENTILATION, AIR CLEANING EQUIPMENT,
COMPRESSORS AND VALVES.
JQA-1452
Organization:
DAIKIN INDUSTRIES
(THAILAND) LTD.
Scope of Registration:
THE DESIGN/DEVELOPMENT
AND MANUFACTURE OF AIR
CONDITIONERS AND THE
COMPONENTS INCLUDING
COMPRESSORS USED FOR THEM
All of the Daikin Group’s business facilities and subsidiaries in Japan are certified under the ISO 14001 international standard for environment management.
Dealer
Head Office:
Umeda Center Bldg., 2-4-12, Nakazaki-Nishi,
Kita-ku, Osaka, 530-8323 Japan
Tokyo Office:
JR Shinagawa East Bldg., 2-18-1, Konan,
Minato-ku, Tokyo, 108-0075 Japan http://www.daikin.com/global_ac/
07/12 P.C.
Specifications, designs and other content appearing in this brochure are current as of July 2012 but subject to change without notice.
20
PCR0709A
1 2
3 4
FTKS25/35E and FTXS25/35E
RKS25/35EB and RXS25/35EB
5
Cooling Only Type
FTKS25EVMA / RKS25EBVMA
Cooling 2.5 (1.2-3.0) kW
8,500 (4,100-10,200) Btu/h
FTKS35EVMA / RKS35EBVMA
Cooling 3.5 (1.2-3.8) kW
11,900 (4,100-12,950) Btu/h
Heat Pump Type
FTXS25EVMA / RXS25EBVMA
Cooling 2.5 (1.2-3.0) kW
8,500 (4,100-10,200) Btu/h
Heating 3.4 (1.2-4.5) kW
11,600 (4,100-15,350) Btu/h
FTXS35EVMA / RXS35EBVMA
Cooling 3.5 (1.2-3.8) kW
11,900 (4,100-12,950) Btu/h
Heating 4.0 (1.2-5.0) kW
13,600 (4,100-17,050) Btu/h
*
* Available with the heat pump type.
FTKS50/60/71F and FTXS50/60/71F
RKS50/60/71F and RXS50/60F
RXS71F
6
Cooling Only Type
FTKS50FVM / RKS50FVM
Cooling 5.0 (1.7-6.0) kW
17,100 (5,800-20,500) Btu/h
FTKS60FVM / RKS60FVM
Cooling 6.0 (1.7-6.7) kW
20,500 (5,800-22,900) Btu/h
FTKS71FVM / RKS71FVM
Cooling 7.1 (2.3-8.3) kW
24,200 (7,800-28,300) Btu/h
Heat Pump Type
FTXS50FVMA / RXS50FVMA
Cooling 5.0 (1.7-6.0) kW
17,100 (5,800-20,500) Btu/h
Heating 5.8 (1.7-7.7) kW
19,800 (5,800-26,300) Btu/h
FTXS60FVMA / RXS60FVMA
Cooling 6.0 (1.7-6.7) kW
20,500 (5,800-22,900) Btu/h
Heating 7.0 (1.7-8.0) kW
23,900 (5,800-27,300) Btu/h
FTXS71FVMA / RXS71FVMA
Cooling 7.1 (2.3-8.5) kW
24,200 (7,800-29,000) Btu/h
Heating 8.2 (2.3-10.0) kW
28,000 (7,900-34,100) Btu/h
*
* Available with the heat pump type.
The DC Inverter series features the Reluctance
DC motor for compressor and DC motor for fan.
This hi-tech energy-saving package is completed by Daikin’s advanced swing compressor and
PAM control. FTXS25E achieves a COP of 4.17,
48% higher than conventional model. This is the result of upgrading from conventional AC inverter to advanced DC Inverter technology.
FTXE25BVMA
FTXS25EVMA
COP
5.00
4.00
3.00
2.00
1.00
2.82
48% higher
4.17
3.09
33% higher
4.10
Cooling operation Heating operation
Inverter Advantages Compared to Non-Inverter
Inverters are devices that are able to vary their operating capacity by adjusting frequency. Inverter air conditioners can vary their heating/cooling capacity by adjusting the power supply frequency of their compressors. In contrast, non-inverter air conditioners have a fixed cooling/heating capacity and can only control the indoor temperature by starting or stopping their compressors.
Powerful
Inverter air conditioners operate at maximum capacity as soon as they start up. As a result, the set temperature can be reached more quickly.
Energy Saving
After the indoor temperature approaches the set temperature,
Inverter Control adjusts to low capacity operation to maintain this temperature. This makes inverter models more energy-saving than non-inverter models, which must repeatedly start or stop their compressors to maintain the room temperature.
Variable Capacity Operation
Inverter Power Control
Power source
High capacity
Low capacity
Non-inverter type air conditioner
Compressor
Power source
Constant speed rotation
Fixed capacity
Inverter air conditioners are able to vary their operating capacity. Non-inverter air conditioners can only operate at a fixed capacity.
Temp.
Raise frequency
Comfortable Temperature Control
Compressor off
Compressor
High-speed rotation
Lower frequency Low-speed rotation
Not cool
Comfortable
Inverter air conditioners finely adjust capacity according to changes in the
Set temp.
air-conditioning load and the difference between the indoor temperature and set temperature is small. These give higher comfort levels than with noninverter air conditioners.
Cools a room in less time
Too cool
Starts
Compressor off
Small temp.
difference
Time
During cooling operation
Non-inverter type
Inverter type
This diagram is a representation for illustrative purpose only.
7
Energy-Saving Technological Features
Swing Compressor
Swing compressor
Thanks to its smooth rotation, the swing compressor decreases friction and vibration. It also prevents the leakage of refrigerant gas during compression. These advantages provide quiet and efficient operation.
Reluctance DC motor
Swing bush
Refrigerant gas
Integral piston of blade and roller
The swing compressor can reduce operational vibration and sound because its piston moves smoothly inside the compressor.
Reluctance DC Motor for Compressor
Neodymium magnets are used in the pink-coloured area.
Daikin DC Inverter models are equipped with the Reluctance DC motor for compressor. The
Reluctance DC motor uses 2 different types of torque, neodymium magnet*
1
and reluctance torque* 2 . This motor can save energy because it generates more power with a smaller electric power than an AC or conventional DC motor. It is more efficient at the low frequencies most commonly used by air conditioners,*
3
improving efficiency by approximately 20%.
*1. A neodymium magnet is approximately 10 times stronger than a standard ferrite magnet.
*2. The torque created by the change in power between the iron and magnet parts.
*3. The frequency range used by air conditioners during periods of stable operation.
This is the range in which air conditioners operate for the longest periods.
Efficiency of Reluctance DC motor
* 4
Reluctance DC motor
90
80
70
60
More than 20%
AC motor
Conventional
DC motor
50
0 30
Small load
Low capacity
60 90 120
Rotational speed (rps)
Large load
High capacity
*4. Data are based on studies conducted under controlled conditions at a Daikin laboratory.
DC Motor for Fan
The DC motor allows fine rotation control, which reduces energy consumption. The motor also provides improvements in operational efficiency of up to 40%, compared to an AC motor. These improvements are particularly noticeable in the low-speed range.
Efficiency of DC motor for fan
*
5
(comparison with a conventional AC motor)
100
80
DC motor
60
Approx.
20% increase
40
20
Approx.
40% increase
AC motor
0
200 300 400 500 600 700 800 900 1000
Motor speed (rpm)
*5. Data are based on studies conducted under controlled conditions at a Daikin laboratory.
PAM Control
PAM (Pulse Amplitude Modulation) control reduces energy loss by controlling how often the converter switches on and off.
What Is DC Inverter?
Daikin calls an inverter model that is equipped with a DC motor DC Inverter. A DC motor offers higher efficiency than an AC motor. A DC motor uses the power of magnets to attract and repel to generate rotation. A DC motor that is equipped with high-power neodymium magnets, which enable even greater efficiency, is called a Reluctance
DC motor.
8
Intelligent Eye
Intelligent Eye prevents energy wastage by using its infrared sensor to detect human movement in a room.
When there is no movement, Intelligent Eye increases/ decreases the temperature by 2 C to give energy savings. This reduces energy wastage if, for example, you forget to turn off the air conditioner.
All models from 2.5 to 7.1 kW class are equipped with Intelligent Eye. This function can be conveniently activated from the remote controller.
Once Intelligent Eye is set, it continues to work to save energy. You do not need to push the SENSOR button each time you wish to use this function.
The Intelligent Eye indicator lights when movement is detected.
Intelligent Eye sensor
Top view
7 m
110˚
Side view
7 m
When you are in the room, the air conditioner maintains the set temperature.
If Intelligent Eye detects no human movement for 20 minutes, it automatically adjusts the set temperature by 2 C.
When you enter the room,
Intelligent Eye automatically returns the temperature to the set level.
Econo Mode button
Intelligent Eye button
Econo Mode
This function limits both the maximum running current and maximum power consumption to 70% of those during normal operation. It is particularly effective if the cooling/heating load is high, for example, at start-up or during large gatherings and periods of direct sunshine.
At the same time, it maintains maximum capacity at
80% of normal, giving improved operating efficiency, although it may take slightly longer to reach the set temperature.
Econo Mode is also useful for preventing circuit breakers from being overloaded during temporary peaks in the running current. The function is easily activated from the remote controller by pushing the
ECONO button. Econo Mode is available for
FTK(X)S25/35E.
Running current and power consumption
100%
Normal operation
70%
Econo
Mode
Maximum during normal operation
Maximum during
Econo Mode
From start-up until set temperature is reached
Time
• This diagram is a representation for illustrative purposes only.
• Maximum capacity decreases during Econo Mode, requiring
more time to reach the set temperature.
9
Indoor Unit Quiet Operation
This series gives you the choice of 5-step, Quiet or
Automatic settings for the fan speed. The Quiet setting selects Indoor Unit Quiet Operation. This function decreases the operation sound level by 3 dB (A) below the Low setting.
This wide range of settings allows you to precisely control the fan speed according to your requirements.
For example, Indoor Unit Quiet Operation provides you with a good night’s sleep. The sound level for FTK(X)S
25E is 22 dB (A).
FTK(X)S25E
Fan speeds
High (H)
Low (L)
Quiet (SL)
During cooling operation
Sound levels
37 dB (A)
25 dB (A)
22 dB (A)
3 dB (A)
Fan speed
Sound level
Auto
Low
SL L M
Each decrease in airflow volume reduces the sound level.
H
High
Indoor Unit Quiet Operation icon
Selects fan speed and
Indoor Unit Quiet Operation
Outdoor Unit Quiet Operation
Outdoor Unit Quiet Operation
Outdoor Unit Quiet Operation is available for all models from 2.5 to 7.1 kW class. This function decreases the operation sound level by 3 or 4 dB (A) below the rated operation. It provides a low sound level of 43 dB (A) for
RK(X)S25EB.
Capacity may decrease when Outdoor Unit Quiet Operation is selected.
RK(X)S25EB
Operations Sound levels
Rated (H)
46 dB (A)
3 dB (A)
Quiet (L)
During cooling operation
43 dB (A)
22 dB (A) Is So Quiet You Can Even Hear Whispers
20 22
Indoor unit
30 40 43
Outdoor unit
50
(dB (A))
10
Rustling of leaves Library
Pendulum of a wall clock Normal office
Based on “Examples of Sound Levels”, Ministry of the Environment, Japan,
November 12, 2002
Titanium Apatite Photocatalytic
Air-Purifying Filter
Titanium apatite is a new photocatalytic material with advanced adsorption power. While the filter’s micronlevel fibres trap dust, this photocatalyst effectively adsorbs and decomposes bacteria.
The photocatalyst is activated simply by exposure to light. The filter delivers consistent performance for approximately 3 years if periodic maintenance is performed.
Titanium Apatite
Photocatalytic
Air-Purifying Filter
Bacteria removal test
Testing method: Dropping method
Testing organisation: Japan Spinners Inspecting Foundation
Result certificate: No. 012553-1 and 012553-2
This filter is not a medical device. Benefits such as the adsorption and decomposition of bacteria are only effective for substances that are collected on and in direct contact with the Titanium Apatite Photocatalytic Air-Purifying Filter.
Effect of Titanium Apatite Photocatalyst
Adsorbs Removes
Light
Apatite adsorbs bacteria.
At the same time, the photocatalyst oxidises odour components, breaking them down.
Odours
Bacteria
Decomposed
Deactivated
Titanium Apatite Photocatalyst
Air filter
Catches dust
Photocatalyst Mechanism
The Titanium Apatite Photocatalytic Air-Purifying Filter incorporates titanium apatite. Titanium apatite is a new photocatalyst material with advanced adsorption power.
When this photocatalyst is exposed to light, a powerful oxidising action occurs.
Light
Photocatalyst
Odours
Active particles
Light strikes the photocatalyst and activates the surface particles.
Odours
A chemical reaction decomposes the odours into CO
2
, O
3
and H
2
.
The odourless substances are released into the air.
11
Mould-Proof Operation
When cooling or dry operation is stopped, fan-only operation runs automatically for 1 hour. This airflow dries the inside of the indoor unit to reduce the generation of mould and odours. It is available with
FTK(X)S25/35E.
Wipe-Clean Flat Panel
Flat panel models can be cleaned instantly with a single wipe of a cloth across their smooth surface. If more thorough cleaning is required, the panel can also be easily removed from the unit.
Conventional Front Grille Design
1. Difficult to remove dust on the grille through wiping alone
Dust
2. Reduced capacity due to increased suction resistance
Front grille design units collect dust on their air inlet grilles unless these grilles are cleaned regularly.
3. High sound levels due to increased suction resistance
12
Inverter Powerful Operation
Inverter Powerful Operation boosts cooling/heating performance for a 20-minute period. This is convenient both when you first turn on your air conditioner and when you want to quickly change the temperature during operation.
Vertical Auto-Swing (up and down)
Horizontal Auto-Swing (left and right)
3-D Airflow
Vertical Auto-Swing automatically moves the flaps up and down and Horizontal Auto-Swing automatically moves the louvers to the left and right. 3-D Airflow combines Vertical and Horizontal Auto-Swing to circulate air to every part of a room for uniform cooling/heating of even large spaces.
Horizontal Auto-Swing and 3-D Airflow are available for FTK(X)S50/60/71F.
Power-Airflow Dual Flaps
Wide-Angle Louvers
Power-Airflow Dual Flaps and Wide-Angle Louvers work in tandem to precisely control both vertical and horizontal airflow for distribution of air.
Power-Airflow Dual Flaps
Cooling: the flaps flatten out during operation so that cool air slides off to reach the corner of the room.
Wide-Angle Louvers
Heating: the flaps descend to blow warm air directly down to the floor to quickly warm the whole room.
From a corner to the centre
The louvers can be adjusted by hand for
FTK(X)S25/35E and with the wireless remote controller for
FTK(X)S50/60/71F.
Covers even a spacious room
13
Indoor Unit On/Off Switch
The unit can be conveniently started manually in the event the wireless remote controller is misplaced or the wireless remote controller batteries are not charged.
Indoor Unit On/Off Switch
Night Set Mode
Pressing the Off timer button automatically selects Night
Set Mode. This function prevents excessive cooling or heating for your pleasant sleep. Room temperature is raised by 0.5 C after 60 minutes for cooling operation and the temperature is lowered by 2 C after 60 minutes for heating operation.
+0.5 C
Set temp. before
Off timer begins to operate
Cooling
2 C Heating
Time
60 minutes
Off timer turns on Off timer stops air conditioner
Cooling operation: Room temperature is raised by 0.5 C after 60 minutes.
Heating operation: Room temperature is lowered by 2 C after 60 minutes.
Home Leave Operation
Home Leave Operation prevents large rises or falls in the indoor temperature by continuing operation* while you are sleeping or out of your home. This means that an air-conditioned welcome awaits when you wake or return. It also means that the indoor temperature can quickly return to your favourite comfort setting.
* Home Leave Operation can be set at any temperature from 18 to 32 C for cooling operation and 10 to 30 C for heating operation.
Home Leave Operation is available for FTK(X)S50/60/71F.
During cooling operation, 23 C for the room temperature setting, and
28 C for the Home Leave setting.
23 C
28 C
23 C
Anticorrosion Treatment of Outdoor
Heat Exchanger Fins
The outdoor unit’s heat exchanger fins are processed using a special anticorrosion treatment. The surface is covered with a thin acrylic resin layer to enhance the fins’ resistance to acid rain and salt corrosion. A hydrophilic film layer also prevents rust caused by the run off of water droplets.
Cross section of anticorrosion-treated fin
Hydrophilic film
Aluminium
Corrosion-resistant acrylic resin
Heat exchanger fin
One push!!
Start Home Leave
Operation simply by pushing its button on the remote controller.
When you are out of your home, your air conditioner prevents large rises/falls in the indoor temperature by continuing to operate using Home Leave
Operation settings.
Wide Operation Range
With the heat pump type FTXS50/60/71F, cooling operation is possible even during outdoor temperatures of as low as 10 C. Heating operation can also be performed during outdoor temperatures of 15 to 18 C.
This makes these units ideal for even very cold areas.
Heat pump type
FTXS50/60/71F
50
40
30
20
10
0
10
20
Cooling
50
40
30
20
10
0
10
20
Heating
Push again!!
When you return, you will be greeted by an airconditioned room. Just push the HOME LEAVE button again to return to your previous settings.
Installation Flexibility
A long piping length gives installation flexibility.
Installation is possible even if there is no space for the outdoor unit near the indoor unit.
FTK(X)S25/35E
FTK(X)S50/60/71F
Max. piping length
20 m
30 m
Max. height difference
15 m
20 m
14
Function Dictionary
Comfortable Airflow
Power-Airflow Dual Flaps
Power-Airflow Dual Flaps can flatten out during cooling operation to deliver cool air to the corners of a room. The flaps can direct warm air straight down to the floor during heating operation.
See page 13
Wide-Angle Louvers
The smoothly curved Wide-Angle Louvers provide wide airflow coverage for effective operation no matter where the indoor unit is placed in a room.
See page 13
Vertical Auto-Swing (up and down)
This function automatically moves the flaps up and down to distribute air across a room.
See page 13
Horizontal Auto-Swing (left and right)
Horizontal Auto-Swing automatically moves the louvers to the left and right to cover a room with cool/warm air.
See page 13
3-D Airflow
This function combines Vertical and Horizontal Auto-
Swing to circulate a cloud of cool/warm air right to the corners of even large spaces.
See page 13
Lifestyle Convenience
Econo Mode
This mode limits maximum running current and power consumption to 70% of normal operation, while maintaining maximum capacity at 80%. This improves operating efficiency and also prevents circuit breakers from being overloaded.
See page 9
Inverter Powerful Operation
This function is convenient for boosting cooling/heating performance for a 20-minute period both when you first turn on your air conditioner or want to quickly change the room temperature.
See page 13
Home Leave Operation
Home Leave Operation continues operation to prevent a room from becoming too hot or cold, while you are sleeping or out of your home. Select any temperature from 18 to 32 C for cooling operation and 10 to 30 C for heating operation.
See page 14
Indoor Unit On/Off Switch
The unit can be conveniently started manually in the event the wireless remote controller is misplaced or the wireless remote controller batteries are not charged.
See page 13
15
Comfort Control
Indoor Unit Quiet Operation
Indoor unit operating sound levels are decreased by 3 dB
(A) from the Low setting fan speed using the wireless remote controller.
See page 10
Outdoor Unit Quiet Operation
Outdoor unit operating sound levels are decreased by 3 or 4 dB (A) from the rated operation sound using the wireless remote controller.
See page 10
Intelligent Eye
Intelligent Eye with its infrared sensor automatically controls air conditioner operation according to human movement in a room. When there is no movement, it adjusts the temperature by 2 C for energy savings.
See page 9
Automatic Operation
This function automatically selects cooling or heating operation mode based on the room temperature at start-up.
Programme Dry Function
This function automatically reduces the level of humidity.
Auto Fan Speed
The microprocessor automatically controls fan speed to adjust the room temperature to the set temperature.
Timers
24-Hour On/Off Timer
This timer can be preset to start and stop at any time within a 24-hour period. The air conditioner is started/ stopped simply by pressing the On/Off timer button on the wireless remote controller.
Night Set Mode
Pressing the Off timer button automatically selects Night
Set Mode. This function prevents excessive cooling or heating for your pleasant sleep. Room temperature is raised by 0.5 C after 60 minutes for cooling operation and the temperature is lowered by 2 C after 60 minutes for heating operation.
See page 13
Worry Free
Auto-Restart after Power Failure
The air conditioner memorises the settings for mode, airflow, temperature, etc., and automatically returns to them when power is restored after a power failure.
Self-Diagnosis with Digital Display
Malfunction codes are shown on the digital display panel of the wireless remote controller for fast and easy maintenance.
Anticorrosion Treatment of Outdoor
Heat Exchanger Fins
The outdoor unit’s heat exchanger fins are processed using a special anticorrosion treatment. The surface is covered with a thin acrylic resin layer to enhance the fins’ resistance to acid rain and salt corrosion.
See page 14
Function List
Cleanliness
Titanium Apatite Photocatalytic
Air-Purifying Filter
This filter contains the new photocatalytic material titanium apatite. While the filter’s micron-level fibres trap dust, this photocatalyst adsorbs and decomposes bacteria. The filter can be used for up to 3 years with proper maintenance.
See page 11
Mould-Proof Operation
Mould-Proof Operation automatically runs fan-only operation for 1 hour when cooling or dry operation is stopped. This airflow prevents the generation of mould and mould odours inside the indoor unit.
See page 12
Wipe-Clean Flat Panel
The flat panel models can be cleaned with only the single pass of a cloth across their smooth surface. The flat panel can also be easily removed for more thorough cleaning.
See page 12
Others
Comfort Control
Quick Warming Function
During low outdoor temperatures, this function pre-heats the compressor to shorten the time required to discharge warm air.
Automatic Defrosting
Before starting heating operation, a sensor checks for frost in the outdoor unit and performs automatic defrosting if necessary so that only warm air is discharged.
Hot-Start Function
After defrosting or when starting heating operation, air is preheated before discharge to prevent uncomfortable cold drafts.
Indoor unit
Functions
Models
Wall-mounted type
FTK(X)S
25/35E
FTK(X)S
50/60/71F
DC Inverter
Power-Airflow
Dual Flaps
Wide-Angle Louvers
Vertical Auto-Swing
(up and down)
Horizontal Auto-Swing
(left and right)
3-D Airflow
Indoor Unit Quiet
Operation
Intelligent Eye
Automatic Operation*
Programme Dry
Function
Auto Fan Speed
Econo Mode
Inverter Powerful
Operation
Home Leave
Operation
Indoor Unit On/Off
Switch
Titanium Apatite
Photocatalytic
Air-Purifying Filter
Mould-Proof
Operation
Wipe-Clean Flat Panel
24-Hour On/Off Timer
Night Set Mode
Auto-Restart after
Power Failure
Self-Diagnosis with
Digital Display
* Available with the heat pump type.
Outdoor unit
Models
RKS25/35EB
RXS25/35EB
RKS50/60/71F
RXS50/60/71F
Functions
Comfort Control
Outdoor Unit
Quiet Operation
Anticorrosion Treatment of Outdoor Heat
Exchanger Fins
Worry Free
16
Easy-to-Use Wireless Remote Controller
Wireless remote controller for FTK(X)S25/35E
Vertical Auto-Swing
(up and down)
Selects fan speed and
Indoor Unit Quiet Operation
Selects mode: automatic, cooling, heating, dry, fan-only operation
Outdoor Unit Quiet Operation
*
Mould-Proof Operation
Intelligent Eye
Cancels On/Off Timer
24-Hour On Timer
24-Hour Off Timer
and Night Set Mode
Sets timer
Sets clock
Wireless remote controller for FTK(X)S50/60/71F
Econo Mode
On/Off Switch
Sets room temperature
Inverter Powerful Operation
*Available with the heat pump type.
Vertical Auto-Swing
(up and down)
Selects fan speed and
Indoor Unit Quiet Operation
Selects mode: automatic, cooling, heating, dry, fan-only operation
Outdoor Unit Quiet Operation
*
Intelligent Eye
Horizontal Auto-Swing
(left and right)
Cancels On/Off Timer
24-Hour On Timer
24-Hour Off Timer
and Night Set Mode
Sets timer
Sets clock
Home Leave Operation
On/Off Switch
Sets room temperature
Inverter Powerful Operation
*Available with the heat pump type.
17
Specifications
FTK(X)S25/35E
Model name
Capacity
Indoor unit
Outdoor unit
Rated
Cooling
(Min.-Max.)
Heating
Rated
(Min.-Max.) kW
Btu/h kW
Btu/h
Power supply
Running current
Power consumption
COP
Cooling
Heating
Cooling
Heating
Cooling
Heating
Rated
Rated
(Min.-Max.)
Rated
Indoor unit
Front panel colour
Airflow rate (H)
Operation range
Piping connections
Cooling
Heating
Fan speed
Sound levels
(H/L/SL)
Cooling
Heating
Dimensions (H x W x D)
Machine weight
Outdoor unit
Casing colour
Type
Compressor
Motor output
Refrigerant charge (R-410A)
Sound levels (H/L)
Cooling
Heating
Dimensions (H x W x D)
Machine weight
Cooling
Heating
Liquid
Gas
Drain
Max. piping length
Max. height difference m
3
A
W
W/W
/min
(cfm) dB (A) mm kg
W kg dB (A) mm kg
CDB
CWB mm m
FTKS25EVMA
RKS25EBVMA
2.5 (1.2-3.0)
8,500 (4,100-10,200)
3.5
Cooling only
600 (300-800)
FTKS35EVMA
RKS35EBVMA
3.5 (1.2-3.8)
11,900 (4,100-12,950)
FTXS25EVMA
Heat pump
FTXS35EVMA
RXS25EBVMA
2.5 (1.2-3.0)
8,500 (4,100-10,200)
3.4 (1.2-4.5)
RXS35EBVMA
3.5 (1.2-3.8)
11,900 (4,100-12,950)
4.0 (1.2-5.0)
13,600 (4,100-17,050) 11,600 (4,100-15,350)
1 phase, 220-240 V/220-230 V, 50/60 Hz
4.9
1,020 (300-1,200)
3.5
4.3
600 (300-800)
830 (290-1,340)
4.9
5.1
1,020 (300-1,200)
1,080 (290-1,550)
4.17
FTKS25EVMA
3.43
3.70
FTXS35EVMA
8.7 (307)
37/25/22
3.43
FTKS35EVMA
4.17
4.10
FTXS25EVMA
White
8.9 (314) 8.7 (307)
9.4 (332)
5 steps, quiet and automatic
38/26/23 37/25/22
283 x 800 x 195
37/28/25
8.9 (314)
9.7 (342)
38/26/23
38/29/26
RKS25EBVMA
46/43
9
RKS35EBVMA RXS25EBVMA
Ivory white
Hermetically sealed swing type
600
1.0
47/44 46/43
47/44
550 x 765 x 285
34
RXS35EBVMA
47/44
48/45
10 to 46 10 to 46
10 to 20
6.4
9.5
18.0
20
15
Note: The above values are based on operation with a 220 V, 50 Hz power supply.
Measurement conditions
1. Cooling capacity is based on: indoor temp. 27 CDB, 19 CWB; outdoor temp. 35 CDB; piping length 7.5 m.
2. Heating capacity is based on: indoor temp. 20 CDB; outdoor temp. 7 CDB, 6 CWB; piping length 7.5 m.
3. Sound levels are based on the temperature conditions 1. and 2. above. These are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of ambient conditions.
Specifications
FTK(X)S50/60/71F
Model name
Capacity
Indoor unit
Outdoor unit
Rated
Cooling
(Min.-Max.)
Rated
Heating
(Min.-Max.) kW
Btu/h kW
Btu/h
Power supply
Cooling
Running current
Heating
Cooling
Power consumption
Heating
COP
Cooling
Heating
Indoor unit
Front panel colour
Airflow rate (H)
Rated
Rated
(Min.-Max.)
Rated
Cooling
Heating
W/W m
3
A
W
/min
(cfm)
Fan speed
Sound levels
(H/L/SL)
Dimensions (H x W x D)
Machine weight
Outdoor unit
Casing colour
Compressor
Refrigerant charge (R-410A)
Cooling
Sound levels (H/L)
Heating
Dimensions (H x W x D)
Machine weight
Type
Motor output
Cooling
Operation range
Heating
Liquid
Piping connections
Cooling
Heating
Gas
Drain
Max. piping length
Max. height difference dB (A) mm kg
W kg dB (A) mm kg
CDB
CWB mm m m
FTKS50FVM
RKS50FVM
5.0 (1.7-6.0)
17,100 (5,800-20,500)
7.2
1,550 (440-2,080)
3.23
FTKS50FVM
14.7 (519)
43/34/31
RKS50FVM
47/44
1,100
1.50
47
Cooling only
FTKS60FVM
RKS60FVM
6.0 (1.7-6.7)
20,500 (5,800-22,900)
9.2
FTXS50FVMA
RXS50FVMA
5.0 (1.7-6.0)
Heat pump
FTXS60FVMA
19,800 (5,800-26,300) 23,900 (5,800-27,300)
1 phase, 220-240 V/220-230 V, 50/60 Hz
11.5
17,100 (5,800-20,500)
5.8 (1.7-7.7)
1,990 (440-2,400)
FTKS71FVM
RKS71FVM
7.1 (2.3-8.3)
24,200 (7,800-28,300)
2,510 (570-3,580)
7.2
7.4
1,550 (440-2,080)
1,600 (400-2,530)
RXS60FVMA
6.0 (1.7-6.7)
20,500 (5,800-22,900)
7.0 (1.7-8.0)
9.2
9.4
1,980 (440-2,390)
2,040 (400-2,810)
3.02
FTKS60FVM
16.2 (572)
2.83
3.23
3.63
FTKS71FVM FTXS50FVMA
White
17.4 (614) 14.7 (519)
16.2 (572)
3.03
3.43
FTXS60FVMA
16.2 (572)
17.4 (614)
45/36/33
RKS60FVM
49/46
5 steps, quiet and automatic
46/37/34 44/35/32
42/33/30
290 x 1,050 x 238
RKS71FVM
12
RXS50FVMA
Ivory white
Hermetically sealed swing type
1,920
1.70
53/49 47/44
48/45
45/36/33
44/35/32
RXS60FVMA
1,100
1.50
49/46
49/46
735 x 825 x 300
55
10 to 46
48
15 to 18
6.4
12.7
15.9
12.7
18.0
30
20
FTXS71FVMA
RXS71FVMA
7.1 (2.3-8.5)
24,200 (7,800-29,000)
8.2 (2.3-10.0)
28,000 (7,900-34,100)
10.8
11.6
2,360 (570-3,200)
2,520 (520-3,730)
3.01
3.25
FTXS71FVMA
17.4 (614)
21.5 (759)
46/37/34
46/37/34
RXS71FVMA
1,920
2.30
52/49
52/49
770 x 900 x 320
71
15.9
Note: The above values are based on operation with a 220 V, 50 Hz power supply.
Measurement conditions
1. Cooling capacity is based on: indoor temp. 27 CDB, 19 CWB; outdoor temp. 35 CDB; piping length 7.5 m.
2. Heating capacity is based on: indoor temp. 20 CDB; outdoor temp. 7 CDB, 6 CWB; piping length 7.5 m.
3. Sound levels are based on the temperature conditions 1. and 2. above. These are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of ambient conditions.
18 19
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project