Aqua F-123 Manual Installation
Advertisement
Advertisement
MAIN DRAIN
MANUAL INSTALLATION
.
MODEL
:
F-123
AQDE18062851
版本
名 称
版 本 编 号
A
规 格
比 例
颜 色
产品负责人
更改内容
新文件
更改日期
AQUA INDUSTRIAL GROUP EM2838 主排水器 英文说明书
AQDE18062851
148X210(mm)
1 : 1
PANTONE Process Black C
材 料
工 艺
日 期
80g 进口纸
双面印刷
2018.06
审核 批准
制图/设计
MAIN DRAIN
IMPORTANT : This instruction manual includes essential information on the safety measures to be implemented for installation and start
up
.
Therefore
, the installer as well as the user must read the instructions before starting installation and start up . Keep this manual for future reference
.
1
. -
MAIN DRAIN
:
Main drains are used to take out water from the deepest part of the pool for the recirculation process
.
It is also used to drain the pool
.(
Fig 1
)
2
. -
INSTALLATION
:
According to the normative , main drains have to be installed as following :
-
Main drains have to be installed in the deepest part of the pool .
The minimum distance between two main drains is 2 meters .
The minimum distance between the main drain and the wall of the pool is 300 mm .
-
The
The maximum maximum water velocity through water velocity in the the grille suction is pipe
0 .
5 m until
/ sec the
.
filtration pump is 1
.
5 m
/ sec
.
The flow rate required for the installation will determine the number of main drains needed .
The maximum flow rate allowed is 13 m
3 / h .
3
. -
MODELS
:
Fig . 1
Imperial connections
Suction Circuit
Hydrostatic valve connection *
Concrete pools
F-123
∅
G2”
1 ½ ”
* Recommends to install a hydrostatic valve ( not included ) on the lower outlet of the main drain exert
(
BSP thread on the pool
1 ½”
), structure in
, order to relieve especially the pressure that potential ground when it is empty or it is Vinyl pool .
water might
4
.-
WARNINGS
:
SUCTION ENTRAPMENT HAZARD
.
Suction in suction outlets and / or suction outlet covers which are damaged , broken , cracked , missing , or unsecured can cause severe injury or death due to the following entrapment hazards
:
4 .
1 . Hair Entrapment -
4 .
2 . Limb Entrapment
Hair
becomes
A limb knotted sucked or or snagged inserted into in an an outlet op ening cover of a
.
circulation
4
.
3
. outlet with a broken or missing cover in the pool resulting in a mechanical bind or
Body Suction Entrapment
-
Suction applied to
resulting in an entrapment .
4 .
4 . Mechanical Entrapment Potential for jewelry , swimsuit , hair decorations , finger , toe or knuckle to be caught in an opening of an outlet or cover .
swelling a large portion of the body or limbs
5
.-
SPARE PARTS LIST
:
1 2 3
POS
.
1
2
3
CODE PRODUCT DESCRIPTION
03017125 Screws M5x10
01050195 Lid
01050198 Body

Public link updated