SPECTRA PRECISION
FOCUS
™
CU
®
III
Spectra Precision
®
FOCUS
®
CU
Part 3
User Guide Software
Version 03.00
Part Number 571 257 401
August 2007
Contact details
Spectra Precision
10355 Westmoore Drive
Suite #100
Westminister, CO 80021
U.S.A.
+1-720-587-4700 Phone
888-477-7516 (Toll Free in U.S.A.) www.spectraprecision.com
Copyrigt and Trademarks
Copyright © 2005-2007, Spectra Precision. All rights reserved.
Autolock, FOCUS, Spectra Precision and Tracklight are trademarks of Spectra Precision, registered in the
United States Patent and Trademark Office and other countries. Spectra Precision logo is a Trademark of
Spectra Precision.
All other trademarks are the property of their respective owners.
Release Notice
This is the August 2007 release version 03.00 of the Spectra Precision FOCUS CU User Guide
Part 2, part number 571257401. It applies to the
Spectra Precision FOCUS CU.
The following limited warranties give you specific legal rights. You may have others, which vary from state/jurisdiction to state/jurisdiction.
Hardware Limited Warranty
Spectra Precision warrants that this hardware product (the “Product”) will perform substantially in accordance with published specifications and be substantially free of defects in material and workmanship for a period of one
(1) year starting from the date of delivery. The warranty set forth in this paragraph shall not apply to software products.
Software License, Limited Warranty
This Spectra Precision software product produced by Trimble®, whether provided as a stand-alone computer software product, built into hardware circuitry as firmware, embedded in flash memory, or stored on magnetic or other media, (the “Software”) is licensed and not sold, and its use is governed by the terms of the relevant End User License Agreement (“EULA”) included with the Software. In the absence of a separate EULA included with the Software providing different limited warranty terms, exclusions and limitations, the following terms and conditions shall apply. Spectra Precision warrants that this Spectra Precision Software product will substantially conform to Spectra
Precision’s applicable published specifications for the Software for a period of ninety (90) days, starting from the date of delivery.
Warranty Remedies
Spectra Precision's sole liability and your exclusive remedy under the warranties set forth above shall be, at Spectra Precision’s option, to repair or replace any Product or Software that fails to conform to such warranty
("Nonconforming Product") or refund the purchase price paid by you for any such
Nonconforming Product, upon your return of any
Nonconforming Product to Spectra Precision in accordance with Spectra Precision’s standard return material authorization procedures.
Warranty Exclusions and Disclaimer
These warranties shall be applied only in the event and to the extent that the Products and
Software are properly and correctly installed, configured, interfaced, maintained, stored, and operated in accordance with Spectra Precision's relevant operator's manual and specifications, and; (ii) the Products and Software are not modified or misused. The preceding warranties shall not apply to, and Spectra Precision shall not be responsible for defects or performance problems resulting from (i) the combination or utilization of the Product or Software with hardware or software products, information, data, systems, interfacing or devices not made, supplied or specified by Spectra Precision; (ii) the operation of the Product or Software under any specification other than, or in addition to,
Spectra Precision's standard specifications for its products; (iii) the unauthorized modification or use of the Product or Software; (iv) damage caused by accident, lightning or other electrical discharge, fresh or salt water immersion or spray; or (v) normal wear and tear on consumable parts (e.g., batteries). Spectra
Precision does not warrant or guarantee the results obtained through the use of the Product.
THE WARRANTIES ABOVE STATE SPECTRA
PRECISION ' S ENTIRE LIABILITY , AND YOUR
EXCLUSIVE REMEDIES , RELATING TO
PERFORMANCE OF THE PRODUCTS AND
SOFTWARE . EXCEPT AS OTHERWISE
EXPRESSLY PROVIDED HEREIN , THE
PRODUCTS , SOFTWARE , AND
ACCOMPANYING DOCUMENTATION AND
MATERIALS ARE PROVIDED “ AS IS ” AND
WITHOUT EXPRESS OR IMPLIED WARRANTY
OF ANY KIND BY EITHER SPECTRA
PRECISION OR ANYONE WHO HAS BEEN
INVOLVED IN ITS CREATION , PRODUCTION ,
INSTALLATION , OR DISTRIBUTION
INCLUDING , BUT NOT LIMITED TO , THE
IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE , TITLE , AND
NONINFRINGEMENT . THE STATED EXPRESS
WARRANTIES ARE IN LIEU OF ALL
OBLIGATIONS OR LIABILITIES ON THE
PART OF SPECTRA PRECISION ARISING
OUT OF , OR IN CONNECTION WITH , ANY
PRODUCTS OR SOFTWARE . S OME
STATES AND JURISDICTIONS DO NOT
ALLOW LIMITATIONS ON DURATION OR
THE EXCLUSION OF AN IMPLIED
WARRANTY , SO THE ABOVE
LIMITATION MAY NOT APPLY TO YOU .
SPECTRA PRECISION IS NOT
RESPONSIBLE FOR THE OPERATION OR
FAILURE OF OPERATION OF GPS
SATELLITES OR THE AVAILABILITY OF
GPS SATELLITE SIGNALS.
Limitation of Liability
SPECTRA PRECISION’ S ENTIRE LIABILITY
UNDER ANY PROVISION HEREIN SHALL BE
LIMITED TO THE AMOUNT PAID BY YOU FOR
THE PRODUCT OR SOFTWARE LICENSE . T O
THE MAXIMUM EXTENT PERMITTED BY
APPLICABLE LAW , IN NO EVENT SHALL
S PECTRA PRECISION OR ITS SUPPLIERS BE
LIABLE FOR ANY INDIRECT , SPECIAL ,
INCIDENTAL OR CONSEQUENTIAL DAMAGES
WHATSOEVER UNDER ANY CIRCUMSTANCE
OR LEGAL THEORY RELATING IN ANY WAY
TO THE PRODUCTS , SOFTWARE AND
ACCOMPANYING DOCUMENTATION AND
MATERIALS , ( INCLUDING , WITHOUT
LIMITATION , DAMAGES FOR LOSS OF
BUSINESS PROFITS , BUSINESS
INTERRUPTION , LOSS OF BUSINESS
INFORMATION , OR ANY OTHER PECUNIARY
LOSS ), REGARDLESS WHETHER SPECTRA
PRECISION HAS BEEN ADVISED OF THE
POSSIBILITY OF ANY SUCH LOSS AND
REGARDLESS OF THE COURSE OF DEALING
WHICH DEVELOPS OR HAS DEVELOPED
BETWEEN YOU AND SPECTRA PRECISION.
B ECAUSE SOME STATES AND JURISDICTIONS
DO NOT ALLOW THE EXCLUSION OR
LIMITATION OF LIABILITY FOR
CONSEQUENTIAL OR INCIDENTAL DAMAGES ,
THE ABOVE LIMITATION MAY NOT APPLY TO
YOU .
NOT WITHSTANDING THE ABOVE, IF YOU
PURCHASED THIS PRODUCT OR
SOFTWARE IN THE EUROPEAN UNION,
THE ABOVE WARRANTY PROVISIONS
MAY NOT APPLY. PLEASE CONTACT YOUR
DEALER FOR APPLICABLE WARRANTY
INFORMATION.
Registration
To receive information regarding updates and new products, please contact your local dealer or visit the Spectra Precision website at www.spectraprecision.com/register .
Upon registration you may select the newsletter, upgrade or new product information you desire.
Notices
Australia and New Zealand
This product conforms with the regulatory
N 1023 requirements of the
Australian Communications Authority (ACA)
EMC framework, thus satisfying the requirements for C-Tick Marking and sale within
Australia and New Zealand.
Canada
This Class B digital apparatus complies with
Canadian ICES-003
This digital apparatus does not exceed the Class
B limits for radio noise emissions from digital apparatus as set out in the radio interference regulations of the Canadian Department of
Communications.
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de Classe
B prescrites dans le règlement sur le brouillage radioélectrique édicté par le Ministère des
Communications du Canada.
Europe
This product has been tested and found to comply with the requirements for a
Class B device pursuant to European
Council Directive 89/336/EEC on EMC, thereby satisfying the requirements for CE Marking and sale within the European Economic Area (EEA).
These requirements are designed to provide reasonable protection against harmful interference when the equipment is operated in a residential or commercial environment.
The compliance to the applicable requirements is detailed in the official Declaration of Conformity document, which is filed at Spectra Precision.
For product recycling instructions and more information, please go to www.spectraprecision.com/ev.shtml
.
Recycling in Europe: To recycle Spectra
Precision WEEE (Waste Electrical and
Electronic Equipment, products that run on electrical power.), Call +31 497 53 24
30, and ask for the "WEEE Associate".
Or, mail a request for recycling instructions to:
Spectra Precision Europe BV c/o Menlo Worldwide Logistics
Meerheide 45
5521 DZ Eersel, NL
USA
Class B Statement – Notice to Users. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communication.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and the receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Changes and modifications not expressly approved by the manufacturer or registrant of this equipment can void your authority to operate this equipment under Federal Communications
Commission rules.
Taiwan
Battery Recycling Requirements
The product contains a removable
Lithium-ion battery. Taiwanese regulations require that waste batteries are recycled.
Table of Contents
In General ......................................................................
1-2
How to use.....................................................................
1-3
In General ......................................................................
2-2
Configuration .................................................................
2-5
Line Intersections...........................................................
2-7
1.1 - Intersection Between Lines .................................. 2-7
1.2 - Offset Intersection .............................................. 2-14
1.3 - Offset Through Points......................................... 2-21
1.4 - Right Angle Intersection..................................... 2-29
2.1 - Points on a Curve................................................ 2-37
2.2 - Curve Intersection............................................... 2-43
Miscellaneous ..............................................................
2-49
3.1 - Perpendicular Offset ........................................... 2-49
3.2 - Centre of Circle .................................................. 2-55
3.3 - Station and Offset ............................................... 2-61
3.4 - Angle and Distance............................................. 2-66
Table of Contents
In General ......................................................................
3-2
Corner + Angle ..............................................................
3-4
Corner + Distance........................................................
Two Lines Intersection.................................................
Eccentric Object...........................................................
Surface ........................................................................
Configure .....................................................................
In General ......................................................................
4-2
Configuration .................................................................
4-4
How to use.....................................................................
4-6
Welcome to Spectra Precision
FOCUS CU
This manual will describe the different softwares that can be installed in Spectra Precision
®
FOCUS
®
CU.
Since FOCUS CU have flexible design it is possible to upgrade software, memory units and other accessories. The various softwares makes it possible to customize your system to your own way of working.
About this manual
The contents of this manual are as follows:
Part 3
Includes available softwares and contains step by step instructions on how to use each software.
- A -
- B -
C H A P T E R
1
1
P60 Athletics
In General ............................................................................ 1-2
How to use ........................................................................... 1-3
1 P60 Athletics
In General
Program 60, Athletics, is a program designed for athletics competitions. It can be used for measuring distances in various events such as javelin, discus and hammer. Before you start the program you must enter the following label texts using program 41, Enter Labels:
Label
90
91
92
93
Text
ROUND
NO
LENGTH
OFFSET
Description enter the current round, e.g. javelin1 the number of the entrant the measured distance of the throw, only in meters radial offset for current event, only in meters
Offset
Centre
Length
Landing point
Figure 1.1
Instrument
Distance definitions
1-2 Spectra Precision FOCUS CU Software
How to use
How to use
Locate the instrument on a suitable point and start program
60. Enter in which Jobfile and in which unit you wish to save the measured data.
PRG 6 0 ENT
Aim towards the centre, see fig. on the previous page, and press A/M to measure the point.
STD P60 10:16
HA:
VA:
A/M
Press REG to register the measurement.
STD P60 10:16
HA:
VA:
SD:
REG
Enter the radial offset and press ENT.
STD P60 10:16
Offset=
ENT
Spectra Precision FOCUS CU Software 1-3
1 P60 Athletics
Javelin=8.00 m
Hammer=1.068 m
Discus=1.25 m
Enter the round of the event and press ENT, e.g. Hammer round 2 can be expressed as Hammer2.
STD P60 10:16
Round=
ENT
Enter the number of the entrant and press ENT.
STD P60 10:16
Entrant
No=
ENT
Measuring mode
You are now in theodolite mode and can start measuring by pressing the A/M key.
STD P60 10:16
HA:
VA:
A/M
1-4 Spectra Precision FOCUS CU Software
How to use
Press REG to register the measurement.
STD P60 10:16
HA:
VA:
SD:
REG
The program has now calculated the length. Round off the length to a lower cm, e.g. 95.158=95.15. Press YES or ENT to store the result or NO to continue without storing.
STD P60 10:16
No=
Length=
Store?
YES
Do you wish to continue with a new measurement, press
ENT. Otherwise press PRG and 0 to exit the program.
STD P60 10:16
Round=
PRG 0
Spectra Precision FOCUS CU Software 1-5
1 P60 Athletics
1-6 Spectra Precision FOCUS CU Software
C H A P T E R
2
2
P61 COGO
In General ............................................................................ 2-2
Configuration........................................................................ 2-5
Line Intersections ................................................................. 2-7
1.1 - Intersection Between Lines..................................... 2-7
1.2 - Offset Intersection................................................. 2-14
1.3 - Offset Through Points ........................................... 2-21
1.4 - Right Angle Intersection........................................ 2-29
2.1 - Points on a Curve ................................................. 2-37
2.2 - Curve Intersection................................................. 2-43
Miscellaneous .................................................................... 2-49
3.1 - Perpendicular Offset ............................................. 2-49
3.2 - Centre of Circle..................................................... 2-55
3.3 - Station and Offset ................................................. 2-61
3.4 - Angle and Distance............................................... 2-66
2 P61 COGO
In General
Program 61, COGO, is calculation program for solving coordinate calculations in field or in the office. It is divided into three main sections, Line intersections, Curve intersections and Miscellaneous. These sections then include a number of subsections depending on the current condition and the type of base information you have. The program also includes a general Configuration part which configures the program behaviour. Please go through this part before you start . When you have calculated a point you can also set it out without leaving the program. To help you understand the different calculation programs, we have chosen to illustrate these by the following figures:
2-2 Spectra Precision FOCUS CU Software
In General
Point C
7
Point A
1
Calculated
Point
2
5
Point D
Point B
1.1 Intersection between lines
7
Point C
1
Point A
7
Point C
7
Point C
Dist. f rom C
D
Calculated
Point
1
Point A
Dist
. fro m A
B
5
Point B
1.2 Offset intersection
2
Point D
Calculated
Point
1
Point A
5
Point B
Point F
4
Calculated
Point
3
Point E
2
Point D
1.3 Offset through points
1
Point A
Calculated
Point
5
Point B
Calculated
Point
Point C
3
Radius from C
5
Point B
Point F
4 3
Point E
Calculated
Point 1
Point B
5
Radius from B
Point A
1
Radius from A
Calculated
Point 2
2
Point D
1.4 Right angle intersection
2.1 Point on a curve
1
Point A
Calculated
Point
5
Point B
3
Point C
3.1 Perpendicular offset
Rado fs
Calculated
Point
RT.o
fs
1
Point A
2.2 Curve intersection
Calculated
Point
1 Point A
5
3
Point C
Point B
3.2 Centre of a circle
Calculated
Point Dist. from A
Angle
1
Point A
5
Point B
3.3 Station and offset
5
Point B
3.4 Angle and distance
Spectra Precision FOCUS CU Software 2-3
2 P61 COGO
Coordinate list
In the following examples we have chosen to use an example from real life. Here below you can find a list of the point coordinates:
6
7
4
5
2
3
Pno
1
N
88345.862
88343.971
88313.151
88296.446
88279.753
88273.289
88276.149
E
99136.879
99153.527
99157.173
99155.277
99153.375
99145.428
99120.184
Fetching point data from an Area file
In the following examples you can use pre-stored point data. You will then be prompted to enter in which Area file these points are stored and in which memory device, Imem or Xmem. To speed up this process you can configure the program to use the first entered Area and memory for the following points.
To simplify the manual and also to use less paper, we have chosen not to show every display that concerns the Area and memory. Instead of these displays we will show the following text block. This means that you are able to key in the Area file you wish to fetch point coordinates from and also to enter in which memory device this file is stored:
2-4 Spectra Precision FOCUS CU Software
Configuration
Enter Area &
Select device
Configuration
To speed up the program you can configure it so it fits your needs. The configuration part can be accessed from every section of the program, under menu option 5 from the line intersection menu, under menu option 3 from the curve intersection menu and under menu option 5 from the miscellaneous menu.
Here follows an explanation of the feature.
Config.
10:17
1 Area change? Yes
2 Store all? No
3 Set out? No
ENT
Press the option number you wish to change.
Press NO to step from the second screen to the first again.
Config.
4 Confirm? Yes
5 Keep AB? No
10:17
Spectra Precision FOCUS CU Software 2-5
2 P61 COGO
Area change
If this is enabled, you are prompted to key in a new area file for each point you enter. If this is disabled, you will only be prompted for the area for the first point.
Store all
If this is enabled, the program automatically stores all keyed in point coordinates.
Set out
If this is enabled, the program gives you the opportunity to turn to set out mode for each point that is calculated. Set out is similar to program 23.
Confirm
If this is enabled, you are prompted to confirm the coordinates for each point that has been fetched from the area file.
Keep AB (does not work in 2, Circle intersections or 3.2
Centre of an circle)
If this is enabled, the program remembers the coordinates for the first line between A and B.
2-6 Spectra Precision FOCUS CU Software
Line Intersections
Line Intersections
Point C
7
Calculated
Point
Point A
1
5
Point B
2
Point D
1.1 - Intersection Between Lines
This program calculates the intersection between the lines
A-B and C-D.
Select program 61 and press ENT.
PRG 6 1 ENT
Select 1 (Line intersec.).
Select 10:17
1 Line intersec.
2 Curve inters.
3 Miscellaneous
1
Spectra Precision FOCUS CU Software 2-7
2 P61 COGO
Select 1 (Int. b/w lines)
Select 10:17
1 Int. b/w lines
2 Offs.intersec.
3 Offs.thr.pts
1
Key in the point number for point A and press ENT.
P61 10:17
Point A
Pno=_
1 ENT
Key in the name of the Area file in which the points are stored and press ENT. If you wish to key in the coordinates manually, leave the line blank and press ENT.
In this case we have stored the points in Area no 1.
P61 10:17
Area=_
1 ENT
2-8 Spectra Precision FOCUS CU Software
Line Intersections
Select in which memory unit you have stored the Area file and press ENT.
Sel.dev.
10:17
1 Imem
2 Xmem
1 ENT
Press ENT to accept the chosen point or NO to choose another point.
P61
Ok?
10:17
N=88345.862
E=99136.879
ENT
Key in the point number for point B and press ENT.
P61 10:17
Point B
Pno=_
5 ENT
Enter Area &
Select device
Spectra Precision FOCUS CU Software 2-9
2 P61 COGO
Press ENT to accept the chosen point or NO to choose another point.
P61
Ok?
10:17
N=88279.753
E=99153.375
ENT
Key in the point number for point C and press ENT.
P61 10:17
Point C
Pno=_
7 ENT
Enter Area &
Select device
Press ENT to accept the chosen point or NO to choose another point.
P61
Ok?
10:17
N=88276.149
E=99120.184
ENT
2-10 Spectra Precision FOCUS CU Software
Line Intersections
Key in the point number for point D and press ENT.
P61 10:17
Point D
Pno=_
2 ENT
Enter Area &
Select device
Press ENT to accept the chosen point or NO to choose another point.
P61
Ok?
10:17
N=88343.971
E=99153.527
This is the calculated point coordinates. Press ENT to store the point or NO to cancel.
P61 10:17
N=88322.145
E=99142.797
Store?
ENT
Spectra Precision FOCUS CU Software 2-11
2 P61 COGO
Key in a number for the calculated point and press ENT.
P61 10:17
Pno=_
ENT
Key in the name of the Areafile in which you wish to store the calculated point and press ENT.
P61 10:17
Area=_
ENT
Here you have the opportunity to choose a Pcode for the calculated point. In this case we choose the call the point
“TP”.
P61 10:17
Pcode=
ENT
2-12 Spectra Precision FOCUS CU Software
Line Intersections
Do you wish to add an elevation to the point before you store it? If so, press ENT, otherwise press NO.
P61 10:17
Pcode=
ELE=?
ENT
Accept the keyed in elevation with ENT or press NO to reenter it.
P61 10:17
Pcode=TP
ELE=12.125
ENT
P61 10:17
Point stored
Now you return to the Line intersection menu. If you wish to step to the main menu, press 6.
Select 10:17
1 Int. b/w lines
2 Offs.intersec.
3 Offs.thr.pts
Spectra Precision FOCUS CU Software 2-13
2 P61 COGO
7
Dist. f
Point C rom C
D Calculated
Point
1
Point A
Dist
. fro m A
B
5
Point B
2
Point D
1.2 - Offset Intersection
This program calculates the intersection between the lines
A-B and C-D if they are dislocated with two offsets, Dist. from AB and Dist. from CD.
Select program 61 and press ENT.
PRG 6 1 ENT
2-14 Spectra Precision FOCUS CU Software
Line Intersections
Select 1 (Line intersec.).
Select 10:17
1 Line intersec.
2 Curve inters.
3 Miscellaneous
1
Select 2 (Offs. intersec.)
Select 10:17
1 Int. b/w lines
2 Offs.intersec.
3 Offs.thr.pts
2
Key in the point number for point A and press ENT.
P61 10:17
Point A
Pno=_
1 ENT
Enter Area &
Select device
Spectra Precision FOCUS CU Software 2-15
2 P61 COGO
Press ENT to accept the chosen point or NO to choose another point.
P61
Ok?
10:17
N=88345.862
E=99136.879
ENT
Key in the point number for point B and press ENT.
P61 10:17
Point B
Pno=_
5 ENT
Enter Area &
Select device
Press ENT to accept the chosen point or NO to choose another point.
P61
Ok?
10:17
N=88279.753
E=99153.375
ENT
Key in the offset, Dist. from AB and press ENT. A positive value means that you are dislocating the line at the right
2-16 Spectra Precision FOCUS CU Software
Line Intersections from point A. In this example we have chosen the offset +1m.
P61 10:17
Offs. intersec.
Dist.from AB
Dist.=
1 ENT
Key in the point number for point C and press ENT.
P61 10:17
Point C
Pno=_
7 ENT
Enter Area &
Select device
Press ENT to accept the chosen point or NO to choose another point.
P61
Ok?
10:17
N=88276.149
E=99120.184
ENT
Spectra Precision FOCUS CU Software 2-17
2 P61 COGO
Key in the point number for point D and press ENT.
P61 10:17
Point D
Pno=_
2 ENT
Enter Area &
Select device
Press ENT to accept the chosen point or NO to choose another point.
P61
Ok?
10:17
N=88343.971
E=99153.527
ENT
Key in the offset, Dist. from CD and press ENT. A positive value means that you are dislocating the line at the right from point C. In this example we have chosen the offset -
1m.
P61 10:17
Offs. intersec.
Dist.from CD
Dist.=
1 ENT
2-18 Spectra Precision FOCUS CU Software
Line Intersections
This is the calculated point coordinates. Press ENT to store the point or NO to cancel.
P61 10:17
N=88322.258
E=99141.738
Store?
ENT
Key in a number for the calculated point and press ENT.
P61 10:17
Pno=_
ENT
Key in the name of the Area file in which you wish to store the calculated point and press ENT.
P61 10:17
Area=_
ENT
Spectra Precision FOCUS CU Software 2-19
2 P61 COGO
Here you have the opportunity to choose a Pcode for the calculated point. In this case we choose the call the point
“TP”.
P61 10:17
Pcode=
ENT
Do you wish to add an elevation to the point before you store it? If so, press ENT, otherwise press NO.
P61 10:17
Pcode=
ELE=?
ENT
Accept the keyed in elevation with ENT or press NO to reenter it.
P61 10:17
Pcode=TP
ELE=12.125
ENT
P61 10:17
Point stored
2-20 Spectra Precision FOCUS CU Software
7
Point C
Line Intersections
Now you return to the Line intersection menu. If you wish to step to the main menu, press 6.
Select 10:17
1 Int. b/w lines
2 Offs.intersec.
3 Offs.thr.pts
1
Point A
5
Point B
Point F
4
Calculated
Point
3
Point E
2
Point D
1.3 - Offset Through Points
This program calculates the intersection between the lines
A-B and C-D if they are dislocated to the points E resp. F.
Select program 61 and press ENT.
PRG 6 1 ENT
Spectra Precision FOCUS CU Software 2-21
2 P61 COGO
Select 1 (Line intersec.).
Select 10:17
1 Line intersec.
2 Curve inters.
3 Miscellaneous
1
Select 3 (Offs. thr. pts)
Select 10:17
1 Int. b/w lines
2 Offs.intersec.
3 Offs.thr.pts
3
Key in the point number for point A and press ENT.
P61 10:17
Point A
Pno=_
1 ENT
Enter Area &
Select device
2-22 Spectra Precision FOCUS CU Software
Line Intersections
Press ENT to accept the chosen point or NO to choose another point.
P61
Ok?
10:17
N=88345.862
E=99136.879
Key in the point number for point B and press ENT.
P61 10:17
Point B
Pno=_
5 ENT
Enter Area &
Select device
Press ENT to accept the chosen point or NO to choose another point.
P61
Ok?
10:17
N=88279.753
E=99153.375
ENT
Spectra Precision FOCUS CU Software 2-23
2 P61 COGO
Key in the point number for point E and press ENT.
P61 10:17
Point E
Pno=_
3 ENT
Enter Area &
Select device
Press ENT to accept the chosen point or NO to choose another point.
P61
Ok?
10:17
N=88313.151
E=99157.173
ENT
Key in the point number for point C and press ENT.
P61 10:17
Point C
Pno=_
7 ENT
Enter Area &
Select device
2-24 Spectra Precision FOCUS CU Software
Line Intersections
Press ENT to accept the chosen point or NO to choose another point.
P61
Ok?
10:17
N=88276.149
E=99120.184
ENT
Key in the point number for point D and press ENT.
P61 10:17
Point D
Pno=_
2 ENT
Enter Area &
Select device
Press ENT to accept the chosen point or NO to choose another point.
P61
Ok?
10:17
N=88343.971
E=99153.527
ENT
Spectra Precision FOCUS CU Software 2-25
2 P61 COGO
Key in the point number for point F and press ENT.
P61 10:17
Point F
Pno=_
4 ENT
Enter Area &
Select device
Press ENT to accept the chosen point or NO to choose another point.
P61
Ok?
10:17
N=88296.446
E=99155.277
ENT
This is the calculated point coordinates. Press ENT to store the point or NO to cancel.
P61 10:17
N=88304.628
E=99159.299
Store?
ENT
2-26 Spectra Precision FOCUS CU Software
Line Intersections
Key in a number for the calculated point and press ENT.
P61 10:17
Pno=_
ENT
Key in the name of the Areafile in which you wish to store the calculated point and press ENT.
P61 10:17
Area=_
ENT
Here you have the opportunity to choose a Pcode for the calculated point. In this case we choose the call the point
“TP”.
P61 10:17
Pcode=
ENT
Spectra Precision FOCUS CU Software 2-27
2 P61 COGO
Do you wish to add an elevation to the point before you store it? If so, press ENT, otherwise press NO.
P61 10:17
Pcode=TP
ELE=?
ENT
Accept the keyed in elevation with ENT or press NO to reenter it.
P61 10:17
Pcode=TP
ELE=12.125
ENT
P61 10:17
Point stored
Now you return to the Line intersection menu. If you wish to step to the main menu, press 6.
Select 10:17
1 Int. b/w lines
2 Offs.intersec.
3 Offs.thr.pts
2-28 Spectra Precision FOCUS CU Software
Line Intersections
7
Point C
Calculated
Point
1
Point A
5
Point B
Point F
4 3
Point E
2
Point D
1.4 - Right Angle Intersection
This program calculates the intersection between the line going through point E, perpendicular to the line A-B, and the line going through point F, perpendicular to the line C-D.
Select program 61 and press ENT.
PRG 6 1 ENT
Select 1 (Line intersec.) and press ENT.*
Select 10:17
1 Line intersec.
2 Curve inters.
3 Miscellaneous
1 ENT
Spectra Precision FOCUS CU Software 2-29
2 P61 COGO
Select 4 (Rt ang. int.)*
Select 10:17
4 Rt ang. int.
5 Config.
6 Main menu
4
Note – * You can also press 1 and 4 directly.
Key in the point number for point A and press ENT.
P61
Point A
Pno=_
10:17
1 ENT
Enter Area &
Select device
Press ENT to accept the chosen point or NO to choose another point.
P61
Ok?
10:17
N=88345.862
E=99136.879
ENT
2-30 Spectra Precision FOCUS CU Software
Line Intersections
Key in the point number for point B and press ENT.
P61 10:17
Point B
Pno=_
5 ENT
Enter Area &
Select device
Press ENT to accept the chosen point or NO to choose another point.
P61
Ok?
10:17
N=88279.753
E=99153.375
ENT
Key in the point number for point E and press ENT.
P61 10:17
Point E
Pno=_
3 ENT
Enter Area &
Select device
Spectra Precision FOCUS CU Software 2-31
2 P61 COGO
Press ENT to accept the chosen point or NO to choose another point.
P61
Ok?
10:17
N=88313.151
E=99157.173
ENT
Key in the point number for point C and press ENT.
P61 10:17
Point C
Pno=_
7 ENT
Enter Area &
Select device
Press ENT to accept the chosen point or NO to choose another point.
P61
Ok?
10:17
N=88276.149
E=99120.184
ENT
2-32 Spectra Precision FOCUS CU Software
Line Intersections
Key in the point number for point D and press ENT.
P61 10:17
Point D
Pno=_
2 ENT
Enter Area &
Select device
Press ENT to accept the chosen point or NO to choose another point.
P61
Ok?
10:17
N=88343.971
E=99153.527
ENT
Key in the point number for point F and press ENT.
P61 10:17
Point F
Pno=_
4 ENT
Enter Area &
Select device
Spectra Precision FOCUS CU Software 2-33
2 P61 COGO
Press ENT to accept the chosen point or NO to choose another point.
P61
Ok?
10:17
N=88296.446
E=99155.277
ENT
This is the calculated point coordinates. Press ENT to store the point or NO to cancel.
P61 10:17
N=88307.213
E=99133.376
Store?
ENT
Key in a number for the calculated point and press ENT.
P61 10:17
Pno=_
ENT
2-34 Spectra Precision FOCUS CU Software
Line Intersections
Key in the name of the Areafile in which you wish to store the calculated point and press ENT.
P61 10:17
Area=_
ENT
Here you have the opportunity to choose a Pcode for the calculated point. In this case we choose the call the point
“TP”.
P61 10:17
Pcode=
ENT
Do you wish to add an elevation to the point before you store it? If so, press ENT, otherwise press NO.
P61 10:17
Pcode=TP
ELE=?
ENT
Spectra Precision FOCUS CU Software 2-35
2 P61 COGO
Accept the keyed in elevation with ENT or press NO to reenter it.
P61 10:17
Pcode=TP
ELE=12.125
ENT
P61 10:17
Point stored
Now you return to the Line intersection menu. If you wish to step to the main menu, press 6.
Select 10:17
1 Int. b/w lines
2 Offs.intersec.
3 Offs.thr.pts
1
Point A
Calculated
Point
5
Point B
Calculated
Point
Point C
3
Radius from C
2-36 Spectra Precision FOCUS CU Software
Line Intersections
2.1 - Points on a Curve
This program calculates the intersection between the line
A-B and the circle at the centre of point C and with a radius of, “Radius from C”.
Select program 61 and press ENT.
PRG 6 1 ENT
Select 2 (Curve intersec.).
Select 10:17
1 Line intersec.
2 Curve inters.
3 Miscellaneous
2
Select 1 (Pts on a curve)
Select 10:17
1 Pts on a curve
2 Curve inters.
3 Config
1
Key in the point number for point A and press ENT.
P61 10:17
Point A
Pno=_
1 ENT
Spectra Precision FOCUS CU Software 2-37
2 P61 COGO
Enter Area &
Select device
Press ENT to accept the chosen point or NO to choose another point.
P61
Ok?
10:17
N=88345.862
E=99136.879
ENT
Key in the point number for point B and press ENT.
P61 10:17
Point B
Pno=_
5 ENT
Enter Area &
Select device
2-38 Spectra Precision FOCUS CU Software
Line Intersections
Press ENT to accept the chosen point or NO to choose another point.
P61
Ok?
10:17
N=88279.753
E=99153.375
ENT
Key in the point number for point C and press ENT.
P61 10:17
Point C
Pno=_
3 ENT
Enter Area &
Select device
Press ENT to accept the chosen point or NO to choose another point.
P61
Ok?
10:17
N=88313.151
E=99157.173
ENT
Spectra Precision FOCUS CU Software 2-39
2 P61 COGO
Key in the radius from C, and press ENT.
If the radius is to small, that is if the circle does not intersect with the line AB, you will get an error message. In this example we key in 25m.
P61 10:17
Radius from C
Radius=
2 5 ENT
This is the first calculated point coordinates. Press ENT to store the point or NO to cancel. In this example we choose only to store the second point.
P61 10:17
N=88331.701
E=99140.413
Store?
NO
This is the second calculated point coordinates. Press ENT to store the point or NO to cancel. In this example we choose to store it with ENT.
P61 10:17
N=88288.901
E=99151.092
Store?
ENT
2-40 Spectra Precision FOCUS CU Software
Line Intersections
Key in a number for the calculated point and press ENT.
P61 10:17
Pno=_
ENT
Key in the name of the Areafile in which you wish to store the calculated point and press ENT.
P61 10:17
Area=_
ENT
Here you have the opportunity to choose a Pcode for the calculated point. In this case we choose the call the point
“TP”.
P61 10:17
Pcode=
ENT
Spectra Precision FOCUS CU Software 2-41
2 P61 COGO
Do you wish to add an elevation to the point before you store it? If so, press ENT, otherwise press NO.
P61 10:17
Pcode=TP
ELE=?
ENT
Accept the keyed in elevation with ENT or press NO to reenter it.
P61 10:17
Pcode=TP
ELE=12.125
ENT
P61 10:17
Point stored
Now you return to the Curve intersection menu. If you wish to step to the main menu, press 4.
Select 10:17
1 Pts on a curve
2 Curve inters.
3 Config
2-42 Spectra Precision FOCUS CU Software
Line Intersections
Calculated
Point 1
Point B
5
Radius from B
Point A
1
Radius from A
Calculated
Point 2
2.2 - Curve Intersection
This program calculates the intersection between the circle at the centre of Point A and with a radius of “Radius from
A”, and the circle at the centre of Point B and with a radius of “Radius from B”.
Select program 61 and press ENT.
PRG 6 1 ENT
Select 2 (Curve inters.)
Select 10:17
1 Line intersec.
2 Curve inters.
3 Miscellaneous
2
Spectra Precision FOCUS CU Software 2-43
2 P61 COGO
Select 2 (Curve inters.)
Select 10:17
1 Pts on a curve
2 Curve inters.
3 Config
2
Key in the point number for point A and press ENT.
P61 10:17
Point A
Pno=_
1 ENT
Enter Area &
Select device
Press ENT to accept the chosen point or NO to choose another point.
P61
Ok?
10:17
N=88345.862
E=99136.879
ENT
2-44 Spectra Precision FOCUS CU Software
Line Intersections
Key in the point number for point B and press ENT.
P61 10:17
Point B
Pno=_
5 ENT
Key in the radius from A, and press ENT. In this example we key in 50m.
Enter Area &
Select device
Press ENT to accept the selected point or NO to choose another point.
P61
Ok?
10:17
N=88279.753
E=99153.375
ENT
Key in the radius from A and press ENT. In this example we key in 50m.
P61 10:17
Curve inters.
Radius from A
Radius=
5 0 ENT
Spectra Precision FOCUS CU Software 2-45
2 P61 COGO
Key in the radius from B and press ENT. In this example we key in 20m.
P61 10:17
Curve inters.
Radius from B
Radius=
2 0 ENT
This is the first calculated point coordinates. Press ENT to store the point or NO to cancel. In this example we choose only to store the second point.
P61 10:17
N=88296.111
E=99141.868
Store?
NO
This is the second calculated point coordinates. Press ENT to store the point or NO to cancel. In this example we choose to store it with ENT.
P61 10:17
N=88299.599
E=99155.847
Store?
ENT
2-46 Spectra Precision FOCUS CU Software
Line Intersections
Key in a number for the calculated point and press ENT.
P61 10:17
Pno=_
ENT
Key in the name of the Area file in which you wish to store the calculated point and press ENT.
P61 10:17
Area=_
ENT
Here you have the opportunity to choose a Pcode for the calculated point. In this case we choose the call the point
“TP”.
P61 10:17
Pcode=
ENT
Spectra Precision FOCUS CU Software 2-47
2 P61 COGO
Do you wish to add an elevation to the point before you store it? If so, press ENT, otherwise press NO.
P61 10:17
Pcode=TP
ELE=?
ENT
Accept the keyed in elevation with ENT or press NO to reenter it.
P61 10:17
Pcode=TP
ELE=12.125
ENT
P61 10:17
Point stored
Now you return to the Curve intersection menu. If you wish to step to the main menu, press 4.
Select 10:17
1 Pts on a curve
2 Curve inters.
2-48 Spectra Precision FOCUS CU Software
Miscellaneous
Miscellaneous
1
Point A
Calculated
Point
5
Point B
3
Point C
3.1 - Perpendicular Offset
This program calculates the intersection between the line
A-B and the line perpendicular to line A-B going through point C.
Select program 61 and press ENT.
PRG 6 1 ENT
Select 3 (Miscellaneous).
Select 10:17
1 Line intersec.
2 Curve inters.
3 Miscellaneous
3
Spectra Precision FOCUS CU Software 2-49
2 P61 COGO
Select 1 (Perpend.offset)
Select 10:17
1 Perpend.offset
2 Cent. of circle
3 Stn and offset
1
Key in the point number for point A and press ENT.
P61 10:17
Point A
Pno=_
1 ENT
Enter Area &
Select device
Press ENT to accept the chosen point or NO to choose another point.
P61
Ok?
10:17
N=88345.862
E=99136.879
ENT
2-50 Spectra Precision FOCUS CU Software
Miscellaneous
Key in the point number for point B and press ENT.
P61 10:17
Point B
Pno=_
5 ENT
Enter Area &
Select device
Press ENT to accept the chosen point or NO to choose another point.
P61
Ok?
10:17
N=88279.753
E=99153.375
ENT
Key in the point number for point C and press ENT.
P61 10:17
Point C
Pno=_
3 ENT
Enter Area &
Select device
Spectra Precision FOCUS CU Software 2-51
2 P61 COGO
Press ENT to accept the chosen point or NO to choose another point.
P61
Ok?
10:17
N=88313.151
E=99157.173
ENT
This is the calculated point coordinates. Press ENT to store the point or NO to cancel.
P61 10:17
N=88310.301
E=99145.752
Store?
ENT
Key in a number for the calculated point and press ENT.
P61 10:17
Pno=_
ENT
2-52 Spectra Precision FOCUS CU Software
Miscellaneous
Key in the name of the Areafile in which you wish to store the calculated point and press ENT.
P61 10:17
Area=_
ENT
Here you have the opportunity to choose a Pcode for the calculated point. In this case we choose the call the point
“TP”.
P61 10:17
Pcode=
ENT
Do you wish to add an elevation to the point before you store it? If so, press ENT, otherwise press NO.
P61 10:17
Pcode=TP
ELE=?
ENT
Spectra Precision FOCUS CU Software 2-53
2 P61 COGO
Accept the keyed in elevation with ENT or press NO to reenter it.
P61 10:17
Pcode=TP
ELE=12.125
ENT
P61 10:17
Point stored
Now you return to the Miscellaneous menu. If you wish to step to the main menu, press 6.
Select 10:17
1 Perpend.offset
2 Cent. of circle
3 Stn and offset
2-54 Spectra Precision FOCUS CU Software
Miscellaneous
Calculated
Point
5
Point C
3
Point B
1 Point A
3.2 - Centre of Circle
This program calculates the centre of a circle going through the points A, B and C.
Select program 61 and press ENT.
PRG 6 1 ENT
Select 3 (Miscellaneous).
Select 10:17
1 Line intersec.
2 Curve inters.
3 Miscellaneous
3
Spectra Precision FOCUS CU Software 2-55
2 P61 COGO
Select 2 (Cent.of circle)
Select 10:17
1 Perpend.offset
2 Cent. of circle
3 Stn and offset
2
Key in the point number for point A and press ENT.
P61 10:17
Point A
Pno=_
1 ENT
Enter Area &
Select device
Press ENT to accept the chosen point or NO to choose another point.
P61
Ok?
10:17
N=88345.862
E=99136.879
ENT
2-56 Spectra Precision FOCUS CU Software
Miscellaneous
Key in the point number for point B and press ENT.
P61 10:17
Point B
Pno=_
3 ENT
Enter Area &
Select device
Press ENT to accept the chosen point or NO to choose another point.
P61
Ok?
10:17
N=88331.151
E=99157.173
ENT
Key in the point number for point C and press ENT.
P61 10:17
Point C
Pno=_
5 ENT
Enter Area &
Select device
Spectra Precision FOCUS CU Software 2-57
2 P61 COGO
Press ENT to accept the chosen point or NO to choose another point.
P61
Ok?
10:17
N=88279.753
E=99153.375
ENT
This is the calculated point coordinates. Press ENT to store the point or NO to cancel.
P61 10:17
N=88302.364
E=99103.277
Store?
ENT
Key in a number for the calculated point and press ENT.
P61 10:17
Pno=_
ENT
2-58 Spectra Precision FOCUS CU Software
Miscellaneous
Key in the name of the Areafile in which you wish to store the calculated point and press ENT.
P61
Area=_
10:17
ENT
Here you have the opportunity to choose a Pcode for the calculated point. In this case we choose the call the point
“TP”.
P61
Pcode==_
10:17
ENT
Do you wish to add an elevation to the point before you store it? If so, press ENT, otherwise press NO.
P61
Pcode=TP
ELE=?
10:17
ENT
Spectra Precision FOCUS CU Software 2-59
2 P61 COGO
Accept the keyed in elevation with ENT or press NO to reenter it.
P61 10:17
Pcode=TP
ELE=12.125
ENT
P61 10:17
Point stored
Now you return to the Miscellaneous menu. If you wish to step to the main menu, press 6.
Select 10:17
1 Perpend.offset
2 Cent. of circle
3 Stn and offset
Rado fs
Calculated
Point
RT.o
fs
1
Point A
5
Point B
2-60 Spectra Precision FOCUS CU Software
Miscellaneous
3.3 - Station and Offset
This program calculates a point which lies at an Right angle offset and a Radial offset from the line A-B.
Select program 61 and press ENT.
PRG 6 1 ENT
Select 3 (Miscellaneous).
Select 10:17
1 Line intersec.
2 Curve inters.
3 Miscellaneous
3 ENT
Select 3 (Stn and offset)
Select 10:17
1 Perpend.offset
2 Cent. of circle
3 Stn and offset
3
Key in the point number for point A and press ENT.
P61 10:17
Point A
Pno=_
1 ENT
Spectra Precision FOCUS CU Software 2-61
2 P61 COGO
Enter Area &
Select device
Press ENT to accept the chosen point or NO to choose another point.
P61
Ok?
10:17
N=88345.862
E=99136.879
ENT
Key in the point number for point B and press ENT.
P61 10:17
Point B
Pno=_
5 ENT
Enter Area &
Select device
2-62 Spectra Precision FOCUS CU Software
Miscellaneous
Press ENT to accept the chosen point or NO to choose another point.
P61
Ok?
10:17
N=88279.753
E=99153.375
ENT
Key in the radial offset from point A and press ENT. A positive value means that the offset is towards point B. In this example we have chosen the offset of +30m.
P61 10:17
Stn and offset
Radofs=_
3 0 ENT
Key in the right angle offset from point A and press ENT. A positive value means that the offset is at the right from point
A. In this example we have chosen the offset of +10m.
P61 10:17
Stn and offset
Radofs=30
Rt.ofs=
1 0 ENT
Spectra Precision FOCUS CU Software 2-63
2 P61 COGO
This is the calculated point coordinates. Press ENT to store the point or NO to cancel.
P61 10:17
N=88310.301
E=99145.752
Store?
ENT
Key in a number for the calculated point and press ENT.
P61 10:17
Pno=_
ENT
Key in the name of the Areafile in which you wish to store the calculated point and press ENT.
P61
Area=_
10:17
ENT
2-64 Spectra Precision FOCUS CU Software
Miscellaneous
Here you have the opportunity to choose a Pcode for the calculated point. In this case we choose the call the point
“TP”.
P61
Pcode=_
10:17
ENT
Do you wish to add an elevation to the point before you store it? If so, press ENT, otherwise press NO.
P61
Pcode=_
ELE=?
10:17
ENT
Accept the keyed in elevation with ENT or press NO to reenter it.
P61 10:17
Pcode=_
ELE=12.125
ENT
P61 10:17
Point stored
Spectra Precision FOCUS CU Software 2-65
2 P61 COGO
Now you return to the Miscellaneous menu. If you wish to step to the main menu, press 6.
Select 10:17
1 Perpend.offset
2 Cent. of circle
3 Stn and offset
Calculated
Point Dist. from A
Angle
1
Point A
5
Point B
3.4 - Angle and Distance
This program calculates a point which lies at an certain angle and a certain offset from the line A-B.
Select program 61 and press ENT.
PRG 6 1 ENT
2-66 Spectra Precision FOCUS CU Software
Miscellaneous
Select 3 (Miscellaneous) and press ENT.
Select 10:17
1 Line intersec.
2 Curve inters.
3 Miscellaneous
3
Select 4 (Angle & dist.)
Select 10:17
4 Angle & dist.
5 Config
6 Main menu
4
Key in the point number for point A and press ENT.
P61 10:17
Point A
Pno=_
1 ENT
Enter Area &
Select device
Spectra Precision FOCUS CU Software 2-67
2 P61 COGO
Press ENT to accept the chosen point or NO to choose another point.
P61
Ok?
10:17
N=88345.862
E=99136.879
ENT
Key in the point number for point B and press ENT.
P61 10:17
Point B
Pno=_
5 ENT
Enter Area &
Select device
Press ENT to accept the chosen point or NO to choose another point.
P61
Ok?
10:17
N=88279.753
E=99153.375
ENT
2-68 Spectra Precision FOCUS CU Software
Miscellaneous
Key in the angle from point A and press ENT. A positive value means a clockwise angle. In this example we have chosen the angle of +10 grads.
P61 10:17
Angle=_
1 0 ENT
Key in the distance from point A and press ENT. A positive value means that the offset is towards point B. In this example we have chosen the offset of +50m.
P61 10:17
Dist from A
Dist.=_
5 0 ENT
This is the calculated point coordinates. Press ENT to store the point or NO to cancel.
P61 10:17
N=88296.053
E=99141.246
Store?
ENT
Spectra Precision FOCUS CU Software 2-69
2 P61 COGO
Key in a number for the calculated point and press ENT.
P61
Pno=_
10:17
ENT
Key in the name of the Areafile in which you wish to store the calculated point and press ENT.
P61
Area=_
10:17
ENT
Here you have the opportunity to choose a Pcode for the calculated point. In this case we choose the call the point
“TP”.
P61
Pcode=_
10:17
ENT
2-70 Spectra Precision FOCUS CU Software
Miscellaneous
Do you wish to add an elevation to the point before you store it? If so, press ENT, otherwise press NO.
P61
Pcode=TP
ELE=?
10:17
ENT
Accept the keyed in elevation with ENT or press NO to reenter it.
P61 10:17
Pcode=TP
ELE=12.125
ENT
P61 10:17
Point stored
Now you return to the Miscellaneous menu. If you wish to step to the main menu, press 6.
Select 10:17
1 Perpend.offset
2 Cent. of circle
3 Stn and offset
Spectra Precision FOCUS CU Software 2-71
2 P61 COGO
2-72 Spectra Precision FOCUS CU Software
C H A P T E R
3
3
P65 Field Application
In General ............................................................................ 3-2
Corner + Angle..................................................................... 3-4
Corner + Distance .............................................................. 3-11
Two Lines Intersection ....................................................... 3-19
Eccentric Object ................................................................. 3-27
Surface............................................................................... 3-33
Configure ........................................................................... 3-43
3 P65 Field Application
In General
Program 65, field Application, is a program for solving coordinate calculations in the field.
Corner + Angle
When you measure an inner corner with a Direct Reflex instrument using reflectorless technology, you can encounter problems with reflections from the wall. When you measure towards an outer corner, reflections from objects in the background can easily disturb your measurement. This program will help you to obtain the exact distance to the error.
Corner + Distance
If the corner you want to measure is hidden, you can simply measure the remaining distance with a tape measure.
Two lines Intersection
When you have to deal with a hidden object, in spite of how you set up the instrument, this intersection program will calculate the point for you.
Eccentric object
When you measure an object you normally want the centre point. This program automatically calculates the centre of the object measured and also the diameter.
3-2 Spectra Precision FOCUS CU Software
In General
Surface
You can automatically measure a surface. Just define the surface and then select the grid you want to use and the instrument will automatically scan that surface.
Spectra Precision FOCUS CU Software 3-3
3 P65 Field Application
Corner + Angle
Point C,
Calculated point
Point A Point B Point C,
Calculated point
Figure 3.2
Measure Corner + Angle.
Start program 65.
PRG 6 5 ENT
Press 1 to measure a corner and angle.
STD P65 12:18
1 Corner (angle)
2 Corner (dist)
3 Two lines int.
1
3-4 Spectra Precision FOCUS CU Software
Corner + Angle
Key in the number or name of the Job file in which you want to store data.
STD P65 12:18
Job No=
ENT
Note – To show display, see Menu 6.1
Choose in which memory unit you want to store your Job file.
STD P65 12:18
1: Imem off
2: Xmem off
3: Serial off
ENT
Note – Only displayed if Job/Mem is switched on
(MNU61)
Measure A.
Measure point A and press ENT.
STD P65 12:18 meas A?
ENT
Spectra Precision FOCUS CU Software 3-5
3 P65 Field Application
Aim to your point, then press A/M to measure the distance.
STD P65 12:18
HA:
VA:
A/M
Note – To display Pno, Pcode and store, see “Configure”
The instrument displays HA, VA, and SD for the point.
Press REG, to register the measurement.
STD P65 12:18
HA:
VA:
SD:
REG
Measure B.
Measure point B and press ENT.
STD P65 12:18 meas B?
ENT
3-6 Spectra Precision FOCUS CU Software
Corner + Angle
Aim to your point, then press A/M to measure the distance.
STD P65 12:18
HA:
VA:
A/M
Note – To display Pno, Pcode and store, see “Configure”
The instrument displays HA, VA, and SD for the point.
Press REG, to register the measurement.
STD P65 12:18
HA:
VA:
SD:
REG
Measure C.
Aim to the point that you want to calculate.
Press REG.
STD P65 12:18
Aim to C
Press REG
REG
Spectra Precision FOCUS CU Software 3-7
3 P65 Field Application
The program automatically increments the Pno by 1. You can also key in another Pno.
Press ENT to accept.
STD P65 12:18
Pno=
ENT
You can choose to enter a Pcode for the point, the last
Pcode used is proposed.
If you leave it blank, this question will not appear for the next point
Press ENT to accept.
STD P65 12:18
Pcode=
ENT
Calculated raw data to point C is displayed.
STD P65 12:18
HA=
VA=
SD=
ENT
3-8 Spectra Precision FOCUS CU Software
Corner + Angle
Calculated coordinate to point C is displayed.
STD P65 12:18
N=
E=
ELE=
ENT
Press 1 to continue, page 3-7.
Press 2 to measure a new point A and B, page 3-5.
STD P65 12:18
1 Continue
2 New A and B
3 Distance
3
Press 3 - The horizontal distance between the two last calculated points will be displayed.
Press YES to store.
STD P65 12:18
HD=
Store?
YES NO
Spectra Precision FOCUS CU Software 3-9
3 P65 Field Application
Press 4 to exit to program 0.
STD P65 12:18
1 Continue
2 New A and B
3 Distance
STD P65 12:18
4 Exit
4
3-10 Spectra Precision FOCUS CU Software
Corner + Distance
Corner + Distance
Point A Point B
Point C,
Calculated point
Figure 3.3
Measure Corner + Distance.
Press 2 to measure corner and distance.
STD P65 12:18
1 Corner (angle)
2 Corner (dist)
3 Two lines int.
2
Spectra Precision FOCUS CU Software 3-11
3 P65 Field Application
Key i the number or name of the Job file in which you want to store data.
STD P65 10:18
Job No=
ENT
Note – To show display, see menu 6.1
Choose in which memory unit you want to store your Job file.
STD P65 10:18
1: Imem off
2: Xmem off
3: Serial off
ENT
Note – Only displayed if Job/Mem is switched on
(MNU61)
Measure A.
Measure point A and press ENT.
STD P65 10:18 meas A?
ENT
3-12 Spectra Precision FOCUS CU Software
Corner + Distance
Aim to your point, then press A/M to measure the distance.
STD P65 10:18
HA:
VA:
A/M
Note – To display Pno, Pcode and store see “Configure”
The instrument displays HA, VA, and SD for the point.
Press REG, to register the measurement.
STD P65 10:18
HA:
VA:
SD:
REG
Measure B.
Measure point B and press ENT.
STD P65 10:18 meas B?
ENT
Note – To display Pno, Pcode and store see “Configure”
Spectra Precision FOCUS CU Software 3-13
3 P65 Field Application
Aim to your point, then press A/M to measure the distance.
STD P65 10:18
HA:
VA:
A/M
The instrument displays HA, VA, and SD for the point.
Press REG, to register the measurement.
STD P65 10:18
HA:
VA:
SD:
REG
Measure distance.
The instrument will automatically position to Point A or B.
Select from which of the points (1 or 2), you manually want to measure the distance to the point that you want to calculate.
STD P65 10:18
1 Dist. from A
2 Dist. from B
1 or
2
3-14 Spectra Precision FOCUS CU Software
Corner + Distance
Enter the Radofs to the point you want to calculate.
STD P65 10:18
Radofs=
ENT
Radofs
Figure 3.4
Radofs / RT.ofs
Enter the Right angle offset.
STD P65 10:18
Rt.ofs=
ENT
The program automatically increments the pno by 1. You can also key in another Pno.
Press ENT to accept.
Spectra Precision FOCUS CU Software 3-15
3 P65 Field Application
STD P65 10:18
Pno=
ENT
You can choose to enter a Pcode for the point, the last
Pcode used is proposed.
Press ENT to accept.
STD P65 10:18
Pcode=
ENT
The instrument displays HA, VA, and SD for the point.
Press REG, to register the measurement.
STD P65 10:18
HA=
VA=
SD=
ENT
3-16 Spectra Precision FOCUS CU Software
Corner + Distance
Calculated coordinate to point C is displayed.
STD P65 10:18
N=
E=
ELE=
ENT
Press 1 to continue, go to “Measure C” on page 3-7.
Press 2 to measure a new point A and B, go to “Measure C”
Press 3 - The horizontal distance between the two last calculated points will be displayed.
Press 4 to exit to program P0.
STD P65 12:18
1 Continue
2 New A and B
3 Distance
STD P65 12:18
4 Exit
4
Spectra Precision FOCUS CU Software 3-17
3 P65 Field Application
Typical Jobfile
71=
7=
8=
9=
0=Calculated point
5=
4=
70=
37=
38=
39=
3-18 Spectra Precision FOCUS CU Software
Two Lines Intersection
Point A Point B
Two Lines Intersection
Point E,
Calculated point
Point C
Figure 3.5
Two lines intersection.
Press 3 to measure two lines intersection.
STD P65 12:18
1 Corner (angle)
2 Corner (dist)
3 Two lines int.
3
Point D
Spectra Precision FOCUS CU Software 3-19
3 P65 Field Application
Key i the number or name of the Job file in which you want to store data.
STD P65 10:18
Job No=
ENT
Note – To show display, see menu 6.1.
Choose in which memory unit you want to store your Job file.
STD P65 10:18
1: Imem off
2: Xmem off
3: Serial off
ENT
Note – Only displayed if Job/Mem is switched on
(MNU61)
Measure A.
Measure point A and press ENT.
STD P65 10:18 meas A?
ENT
3-20 Spectra Precision FOCUS CU Software
Two Lines Intersection
Note – To display Pno, Pcode and store, see “Configure”
Aim to your point, then press A/M to measure the distance.
STD P65 10:18
HA:
VA:
A/M
The instrument displays HA, VA, and SD for the point.
Press REG, to register the measurement.
STD P65 10:18
HA=
VA=
SD=
REG
Measure B
Measure point B and press ENT.
STD P65 10:18 meas B?
ENT
Note – To display Pno, Pcode and store, see “Configure”
Spectra Precision FOCUS CU Software 3-21
3 P65 Field Application
Aim to your point, then press A/M to measure the distance.
STD P65 10:18
HA:
VA:
A/M
The instrument displays HA, VA, and SD for the point.
Press REG, to register the measurement.
STD P65 10:18
HA=
VA=
SD=
REG
Measure C
Measure point C and press ENT.
STD P65 10:18 meas C?
ENT
3-22 Spectra Precision FOCUS CU Software
Two Lines Intersection
Aim to your point, then press A/M to measure the distance.
STD P65 10:18
HA:
VA:
A/M
The instrument displays HA, VA, and SD for the point.
Press REG, to register the measurement.
STD P65 10:18
HA=
VA=
SD=
REG
Measure D
Measure point D and press ENT.
STD P65 10:18 meas D?
ENT
Note – To display Pno, Pcode and store, see “Configure”
Spectra Precision FOCUS CU Software 3-23
3 P65 Field Application
Aim to your point, then press A/M to measure the distance
STD P65 10:18
HA:
VA:
A/M
The instrument displays HA, VA, and SD for the point.
Press REG, to register the measurement.
STD P65 10:18
HA=
VA=
SD=
REG
The program automatically increments the Pno by 1. You can also key in another Pno.
Press ENT to accept.
STD P65 10:18
Pno=
ENT
You can choose to enter a Pcode for the point, the last
Pcode used is proposed.
If you leave it blank, this question will not appear for the next point.
Press ENT to accept.
3-24 Spectra Precision FOCUS CU Software
Two Lines Intersection
STD P65 10:18
Pcode=
ENT
The instrument displays HA, VA, and SD for the point.
STD P65 10:18
HA=
VA=
SD=
REG
Calculated coordinate to point E is displayed.
STD P65 10:18
N=
E=
ELE=
ENT
Press 1 to continue, go to “Measure distance”
Press 2 to measure a new point A and B, go to “Measure
Press 3 - The horizontal distance between the two last calculated points will be displayed.
Press 4 to exit to Program 0.
Spectra Precision FOCUS CU Software 3-25
3 P65 Field Application
STD P65 12:18
1 Continue
2 New A and B
3 Distance
STD P65 12:18
4 Exit
Typical Jobfile
8=
9=
37
38
39
0=Calc.Point
5=
4=
7=
3-26 Spectra Precision FOCUS CU Software
Eccentric Object
Eccentric Object
Diameter (calculated)
Calculated point
Point A
Radius
Figure 3.6
Eccentric Object.
Spectra Precision FOCUS CU Software 3-27
3 P65 Field Application
Press 4 to measure an Eccentric object.
STD P65 12:18
1 Corner (angle)
2 Corner (dist)
3 Two lines int.
STD P65 12:18
4 Eccentric
5 Surface
6 Config
4
Key i the number or name of the Job file in which you want to store data.
STD P65 10:18
Job No=
ENT
Note – To show display, see menu 6.1
Choose in which memory unit you wish to store your Job file.
STD P65 10:18
1: Imem off
2: Xmem off
3: Serial off
ENT
Note – Only displayed if Job/Mem is switched on
(MNU61)
3-28 Spectra Precision FOCUS CU Software
Eccentric Object
Measure A
Measure point A and press ENT.
STD P65 10:18 meas A?
ENT
Note – To display Pno, Pcode and store, see “Configure”
Aim to your point, then press A/M to measure the distance
STD P65 10:18
HA:
VA:
A/M
The instrument displays HA, VA, and SD for the point.
Press REG, to register the measurement.
STD P65 10:18
HA=
VA=
SD=
REG
Spectra Precision FOCUS CU Software 3-29
3 P65 Field Application
Aim to the edge, press REG to register the measurement.
STD P65 10:18
Aim to Edge
Press REG
REG
Calculated diameter of the measured object is displayed.
Press ENT to accept.
STD P65 10:18
Diam= ok?
ENT
The program automatically increments the Pno by 1. You can also key in another Pno.
Press ENT to accept.
STD P65 10:18
Pno=
ENT
You can choose to enter a Pcode for the point, the last
Pcode used is proposed.
If you leave it blank, this question will not appear for the next point.
Press ENT to accept.
3-30 Spectra Precision FOCUS CU Software
Eccentric Object
STD P65 10:18
Pcode=
ENT
The instrument displays HA, VA, and SD for the calculated point.
Press REG, to register the measurement.
STD P65 10:18
HA:
VA:
SD:
ENT
Calculated coordinate to the calculated point is displayed.
STD P65 10:18
N=
E=
ELE=
ENT
Press 1 to continue, go to “Measure A”, on page 3-29.
Press 2 - The horizontal distance between the two last calculated points will be displayed.
Press 3 to exit to program 0.
STD P65 10:18
1 Continue
2 Distance
3 Exit
Spectra Precision FOCUS CU Software 3-31
3 P65 Field Application
Typical Jobfile
7=
8=
9=
37
0=Calc.Point
5=
4=
63=
38
39
3-32 Spectra Precision FOCUS CU Software
Surface
HD
VD
Surface
Figure 3.7
Spectra Precision FOCUS CU Software 3-33
3 P65 Field Application
Press 5 to measure a surface
STD P65 12:18
1 Corner (angle)
2 Corner (dist)
3 Two lines int.
STD P65 12:18
4 Eccentric
5 Surface
6 Config
5
Key i the number or name of the Job file in which you want to store data.
STD P65 12:18
Job No=
ENT
Note – To show display, see Menu 6.1
Choose in which memory unit you want to store your Job file.
STD P65 12:18
1: Imem off
2: Xmem off
3: Serial off
ENT
Note – Only displayed if Job/Mem is switched on
(MNU61)
3-34 Spectra Precision FOCUS CU Software
Surface
Measure A.
Measure point A and press ENT.
STD P65 12:18 meas A?
Upper left
ENT
Aim to your upper left point, then press A/M to measure the distance.
STD P65 12:18
HA:
VA:
A/M
Note – To display Pno, Pcode and store, see “Configure”
The instrument displays HA, VA, and SD for the point.
Press REG, to register the measurement.
STD P65 12:18
HA:
VA:
SD:
REG
Spectra Precision FOCUS CU Software 3-35
3 P65 Field Application
Measure B.
Measure point B and press ENT.
STD P65 12:18 meas B?
Upper right
ENT
Aim to your upper right point, then press A/M to measure the distance.
STD P65 12:18
HA:
VA:
A/M
Note – To display Pno, Pcode and store, see “Configure”
The instrument displays HA, VA, and SD for the point.
Press REG, to register the measurement.
STD P65 12:18
HA:
VA:
SD:
REG
3-36 Spectra Precision FOCUS CU Software
Surface
Measure C
Measure point C and press ENT.
STD P65 10:18 meas C?
Bottom
ENT
Aim to your bottom point, then press A/M to measure the distance.
STD P65 10:18
HA:
VA:
A/M
Note – To display Pno, Pcode and store, see “Configure”
The instrument displays HA, VA, and SD for the point.
Press REG, to register the measurement.
STD P65 10:18
HA=
VA=
SD=
REG
Spectra Precision FOCUS CU Software 3-37
3 P65 Field Application
Press 1 to do an automatic measurement.
Select
1 Automatic
2 Manual
3 New A and B
1
Key in the horizontal and vertical distance.
STD P65 10:18
HD:
VD:
ENT
Calculated number of points to be measured is displayed and the time estimated to measure them. Press ENT to accept or press or NO if you want to change the keyed in
HD and VD.
STD P65 12:18
Points = XX
Time = X min
Ok?
ENT
3-38 Spectra Precision FOCUS CU Software
Percentage of memory used is displayed.
STD P65 12:18
Use of free mem
8%
Ok?
ENT
Key in the Pno you want to start with. The program automatically increments. Press ENT to accept.
STD P65 12:18
Pno =
Surface
ENT
You can choose to enter a Pcode for the point, the last
Pcode used is proposed. Press ENT to accept.
STD P65 12:18
Pcode =
ENT
Spectra Precision FOCUS CU Software 3-39
3 P65 Field Application
A positioning is being made.
STD P65 12:18
Aim to point x/xx
Please Wait
ENT
STD P65 12:18
Scanning......
Note – Scanning only displayed on Direct Reflex instruments with reflectorless technology.
The measurement will continue until all points are measured.
STD P65 12:18
Measuring......
S.Dev = x.xxx
Note – Note! If a point can not be measured or if the S.Dev is not reached, the measurement will stop after 15 s.
The number of Good points (measured points) and Bad points (not measured points) are displayed. Press NO if you
3-40 Spectra Precision FOCUS CU Software
Surface want to check the bad points. (Press YES to return to
Program 65 main menu).
STD P65 12:18
Good pts =
Bad pts =
Ok?
NO
If you have more than 10 bad points only the first 10 will be checked. Press YES to start. (Press NO to return to
Program 65 main menu).
STD P65 12:18
Check point
Ok?
YES
A positioning to the bad point is being made.
STD P65 12:18
Aim to point x/xx
Please Wait
Spectra Precision FOCUS CU Software 3-41
3 P65 Field Application
The instrument aims at the point that could not be measured. Press YES to remeasure the point. Press NO to check the next bad point.
STD P65 12:18
Remeasure point
Ok?
YES
3-42 Spectra Precision FOCUS CU Software
Configure
Configure
Store, Calc
Select if you want to configure Store Measure points or
Store Calculated points.
Press 1.
STD P65 10:18
1 Store, Measure
2 Store, Calc
3 Exit
1
Press 1.
STD P65 12:18
1 Other
2 Surface auto
3 Exit
1
Spectra Precision FOCUS CU Software 3-43
3 P65 Field Application
Store
Store measured data by selecting 3. User table data for the
“help points” can also be stored, normally this can be left empty.
STD P65 10:18
1 Exit
2 View table
3 Enter user table
2
Press 2 to view table.
Press ENT.
STD P65 10:18
User tbl.
(Table empty)
Press ENT
ENT
Typical Data can look like this;
Label - 0, 5, 4, 7, 8, 9, 37, 38, 39
STD P65 10:18
User tbl. pos 1
Label no=
3-44 Spectra Precision FOCUS CU Software
Configure
Calculated point
Press 2.
STD P65 10:18
1 Store, Measure
2 Store, Calc
3 Exit
1
Set what you want to configure.
(Selection 2 in the config menu.)
STD P65 10:18
1 Angle & 2 Lines
2 Dist
3 Eccentric pt
STD P65 10:18
4 Surface (man)
5 Exit
Angle and two lines
0, 5, 4, 7, 8, 9, 37, 38, 39 = Default
Info, Pno, Pcode, HA, VA, SD, N, E, ELE
STD P65 10:18
1
Spectra Precision FOCUS CU Software 3-45
3 P65 Field Application
Distance
70, 71, 0, 5, 4, 7, 8, 9, 37, 38, 39 = Default
Info, Radolfs, Rtofs, Pno; Pcode, HA, VA, SD
STD P65 10:18
2
Eccentric
0, 5, 4, 63, 7, 8, 9, 37, 38, 39 = Default info, Pno, Pcode, Diam, Ha, VA, SD, N, E, Ele
STD P65 10:18
3
3-46 Spectra Precision FOCUS CU Software
C H A P T E R
4
4
P66 Monitoring
In General ............................................................................ 4-2
Configuration........................................................................ 4-4
How to use ........................................................................... 4-6
4 P66 Monitoring
In General
Program 66, Monitoring, The Monitoring program for servo-driven instruments lets you monitor known points stored in an Area file. The software measures the current position of the known points to detect changes in their position.
Points are monitored in one of two modes: Automatic or
Manual.
When the software is in Automatic mode, the servo-driven instrument automatically positions itself before measuring each point. If an active target (RMT) is used the complete movement will be detected (Slope Monitoring), if a prism is used the distance movement will be detected (Monitoring).
In Manual mode, the instrument positions itself, but fine adjustments might be needed (Slope Monitoring).
The Monitoring function is useful for many applications.
For example, use it to make sure known points on a building or structure have not moved.
• Monitoring preparations:
– Establish the Station
– Determine and store coordinates of the points to be monitored in an Area file
• Choice of performance:
– Single loop
Single loop will monitor points in a selected area file once.
– Number of loops “Loop=X”
Number of loops will monitor points in a selected area file a number of times. The number of times is set by the
4-2 Spectra Precision FOCUS CU Software
In General operator, the value can be set between 2 and 5000. The operator can also set the length of the pause between loops, the length of the pause can be between 0 and 2880 seconds
(2 days).
–
Loop “Pause=X”(minutes)
Loop will monitor points in a selected area file continuously. The operator can set the length of the pause between loops, the length of the pause can be between 0 and 2880 seconds (2 days).
The program will compare new positions with positions in the selected area file. The number of points within error limits will be displayed as good points, points deviating more than set error limits will be displayed as bad points.
Spectra Precision FOCUS CU Software 4-3
4 P66 Monitoring
Configuration
The configuration part can be accessed by a long press on the PRG-key. Press DIR and select program 66 Monitoring and press ENT.
The instrument will display the software version and the selected program P66.
Prg P66 10:17
Inst.
632-10.00
Monitoring
ENT
Select 2 Config.
P66
1 Run
2 Config
10:17
2
Press ENT.
P66 10:17
1 Exit
2 View table
3 Enter user tbl
ENT
4-4 Spectra Precision FOCUS CU Software
Configuration
Select 5 Options to set the error limit.
P66 10:17
4 Clear user tbl
5 Options
5
Key in the selected error limit for Radofs and press ENT.
P66 10:17
Error limits
Radofs=X.XXXX
ENT
Key in the selected error limit for RTofs and press ENT.
P66 10:17
Error limits
Radofs=X.XXXX
RTofs=X.XXXX
ENT
Key in the selected error limit for DiffZ and press ENT.
P66 10:17
Error limits
DiffZ=X.XXXX
ENT
Spectra Precision FOCUS CU Software 4-5
4 P66 Monitoring
Select 1 Exit to exit.
P66 10:17
1 Exit
2 View table
3 Enter user tbl
1
The Monitoring program P66 can be started from here by pressing 1 Run.
How to use
Select program 66 monitoring.
PRG 6 6 ENT
Key in the number of the Jobfile in which you want to store the data. Then press ENT.
P66 10:17
Job No=_
ENT
Note – Displayed if Job/Mem is switched on (MNU61)
4-6 Spectra Precision FOCUS CU Software
How to use
Activate the device you wish for storage of the Job file by choosing the appropriate number 1, 2 or 3.
P66 10:17
1: Imem on
2: Xmem off
3: Serial off
1 2 ENT
Note – Only displayed if Job/Mem is switched on
(MNU61)
This was the Station No. you entered in program 20, Station
Establishment. Press ENT.
If no station establishment has been made, P66 will automatically propose establishment of a known or free station (P20) when you press ENT.
P66 10:17
Stn=1000
ENT
Note – Only displayed if Stn is switched on (MNU61)
Key in the Area file number in which the point coordinates are stored and press ENT.
P66 10:17
Area =_
ENT
Spectra Precision FOCUS CU Software 4-7
4 P66 Monitoring
Choose what type of device in which the points are stored.
P66 10:17
1 Imem
2 Xmem
1
Key in the signal height and press enter.
P66 10:17
SH=X.XXX
ENT
Select 1 Single loop, 2 Number of loops or 3 Loop.
Select P66 10:17
1 Single loop
2 Num. of loops
3 Loop
If 2 Number of loops is selected the operator can decide how many loops the instrument shall make and how long the pause between the loops shall be. The operator will be
4-8 Spectra Precision FOCUS CU Software
How to use prompted to key in the number of loops, values between 2 and 5000 can be entered
P66 10:17
Loop=X
ENT
The operator will then be prompted to key in the length of the pause between the loops, values between 0 and 2880 sec (2 days) can be entered.
P66 10:17
Pause=X
ENT
If 3 Loop is selected the instrument will continue until stopped by operator. The operator can decide how long the pause between the loops shall be. The operator will be prompted to key in the length of the pause between the loops, values between 0 and 2880 sec (2 days) can be entered.
P66 10:17
Pause=X
ENT
Spectra Precision FOCUS CU Software 4-9
4 P66 Monitoring
If 1 Single loop is selected the instrument will make one loop and stop. In this case we will select 1 Single Loop.
Select P66 10:17
1 Single loop
2 Num. of loops
3 Loop
1
Select the type of target used, 1 Reflector, 2 DR (Only
Direct Reflex instruments with reflectorless technology) or 3
Active target (Only instrument with tracker). In this case we will select 1 Reflector. If 3 Active target is selected the program will skip the selection of manual or automatic mode and go directly to the selection of measuring mode.
Select P66 10:17
1 Reflector
2 DR
3 Active target
1
Select 1 Manual or 2 Automatic mode, in this case we will select 1 Manual mode.
Select P66 10:17
1 Manual
2 Automatic
1
4-10 Spectra Precision FOCUS CU Software
How to use
Select 1 Std for standard measurement or 2 D_bar. In this case we will select 1 Std.
Select P66 10:17
1 Std
2 D_bar
1
If automatic has been selected and D_bar is selected at his moment then the operator will be prompted to select the number of measurments.Key in the selected number of measurements and press ENT
P66 10:17
No.of meas.=X
ENT
If you have entered a Pcode for the point you can enter the desired Pcode here. The program will then seek for the point with that Pcode. If you have no Pcode just leave the line blank and press ENT.
P66 10:17
Pcode =_
ENT
Spectra Precision FOCUS CU Software 4-11
4 P66 Monitoring
Wait for the instrument to find and measure the selected position.
P66 10:17
Please wait
The horizontal and vertical angle is displayed when the position is found. If needed adjust the aiming of the instrument and press A/M to measure the point. This display is not shown if Automatic mode has been selected.
STD P66 10:17
HA: 310.8390
VA: 98.1720
A/M
The measured position is displayed, press REG to save.
This display is not shown if Automatic mode has been selected.
STD P66 10:17 dHA: X.XXXX
dVA: X.XXX
dHT: X.XXX
REG
Wait for the instrument to calculate the next point.
P66 10:17
Please wait
4-12 Spectra Precision FOCUS CU Software
How to use
After the last point in the area file has been measured the instrument will display the number of good and bad points.
The measured points are compared with the values set by the operator in the configuration. If OK press ENT to return to program 0 (P0).
STD P66 10:17
Good pts=X
Bad pts=X
OK?
ENT
If the instrument has been set to make several loops and a pause has been set between the loops the instrument will display the time until the next loop begins.
Press ENT to return to program 0 (P0).
STD P66 10:17
Good pts=X
Bad pts=X
Pause x min.....
ENT
The program will return to program 0.
STD P0 10:17
Temp=XX
Spectra Precision FOCUS CU Software 4-13
4 P66 Monitoring
4-14 Spectra Precision FOCUS CU Software