This document guides the installer through the complete process of configuring and deploying a Savant Power System, including:

– Wiring Savant Power Modules and breakers

– Creating a Savant Power & Light app Account and Home

– Scanning for Savant Power Modules and pairing them

– Adding and editing breaker panels and modules within the Savant Power & Light app.

– Adding a battery power source to automatically switch to during a power outage

– Creating Energy Scenes to control power usage off the grid

– Upload configuration to a Savant Power Director

Copyright © 2022 Savant Systems Inc.

45 Perseverance Way, Hyannis, MA 02601

Savantpower.com

| 508.683.2500

Savant Power® Panel Deployment Guide

Table of Contents

To access links to the topics within this document, click the corresponding entry in the table below.

1.

2.

Important Safety Information ....................................................................................3

Before You Begin ............................................................................................................4

Deployment Steps ..........................................................................................................4

11.2. Breaker Panel Settings ..................................................................................... 24

11.3. Slots ......................................................................................................................... 25

11.4. Add Modules (Optional) .................................................................................. 26

11.5. Pair Added Savant Power Modules (Optional) ........................................27

11.6. Assign Circuit Name (Optional) .................................................................... 28

3. Gestures .............................................................................................................................5

4. Third Party Documentation ........................................................................................5

5. Wiring Diagrams .............................................................................................................6

5.1. Dual 20 Amp Relay Savant Power Module ..................................................6

5.2. 240V AC 2-Pole Savant Power Relay Module ............................................8

5.3 240V 60A Savant Power Relay Module ........................................................9

5.4. Contactor Wiring Diagram ...............................................................................10

5.5. MicroGrid Storage Wiring Diagram ............................................................... 11

5.6. MicroGrid Three-Line Wiring Diagram ........................................................ 12

12. Energy Monitoring ...................................................................................................... 29

11.1 VT and CT Placement ....................................................................................... 29

11.2 Configure Current Monitors ............................................................................30

11.3 Channel Settings ................................................................................................. 33

11.4 Contact Linking ................................................................................................... 34

11.5. Add Power Source ............................................................................................. 35

11.6. Configure Power Source (Optional) ............................................................ 36

11.7 Power Source Settings ......................................................................................37

13. Circuits .............................................................................................................................40

6. Power Source Requirements .................................................................................... 13

7. On-Device Setup........................................................................................................... 14

6.1. Configure Savant Power Module Channels ................................................ 14

6.2. Pair Savant Power Modules ............................................................................. 15

6.3. Director Hotspot .................................................................................................. 16

12.1 Dedicated Circuits ..............................................................................................40

12.2. Configure Circuits ................................................................................................ 41

13. Energy Scenes .............................................................................................................. 42

11.1. Create Energy Scene ......................................................................................... 42

11.2. Energy Budget ..................................................................................................... 43

8. App Setup ....................................................................................................................... 17

6.1. Create Home.......................................................................................................... 17

6.2. Add Photo .............................................................................................................. 18

6.3. Discover Devices .................................................................................................. 19

6.4. Energy Dashboard .............................................................................................20

15.

16.

11.2. Edit Scene Loads ................................................................................................44

Upload Configuration ................................................................................................ 45

Confirm System Functionality ................................................................................46

9. Get Config ....................................................................................................................... 21

Appendix A: Pair Button Functions ...................................................................... 47

10. Test Circuits ................................................................................................................... 22

Appendix B: Schneider ESS and Conext MiniPDP ......................................... 48

11. Breaker Panels .............................................................................................................. 23

11.1. Configure Breaker Panel .................................................................................. 23

Savant Power® Panel Deployment Guide

009-2140-00 | 042522 - 2 -

Appendix C: System Information Checklist .......................................................50

Important Notice ...................................................................................................................... 51

Copyright 2022 Savant Systems, Inc

Savant Power® Panel Deployment Guide

Important Safety Information - Read First

Before installing, configuring, or operating any equipment, Savant recommends that each dealer, integrator, installer, etc. access and read all relevant technical documentation. Savant Power technical documentation can be located by visiting Savantpower.com

. Vendor documentation is supplied with the equipment.

Read and understand all safety instructions, cautions, and warnings in this document and the labels on the equipment.

Safety Classifications In this Document

NOTE :

Provides special information for installing, configuring, and operating the equipment.

IMPORTANT!

CAUTION!

WARNING!

Provides special information that is critical to installing, configuring, and operating the equipment.

Provides special information for avoiding situations that may cause damage to equipment.

Provides special information for avoiding situations that may cause physical danger to the installer, end user, etc.

Electric Shock Prevention

ELECTRIC

SHOCK!

The source power poses an electric shock hazard that has the potential to cause serious injury to installers and end users.

ELECTRICAL

DISCONNECT :

The source power outlet and power supply input power sockets should be easily accessible to disconnect power in the event of an electrical hazard or malfunction.

Weight Injury Prevention

WEIGHT INJURY!

Installing some of the Savant equipment requires two installers to ensure safe handling during installation.

Failure to use two installers may result in injury.

Safety Statements

All safety instructions below must be read, understood, and carefully followed under all applicable circumstances when working with any Savant equipment.

1. Follow all input power ratings marked on product near power input!

2. If fuse replacement is required, replacement fuse should match fuse rating marked on the product.

3. Do not use equipment near water.

4. Clean only with dry cloth.

5. Do not block any ventilation openings or install near any heat sources such as heat registers, stoves, radiators, amplifiers, etc.

6. Refer all servicing to qualified service personnel. Servicing is required when any part of the apparatus has been damaged in any way, or fails to operate normally for any reason.

7. Use only attachments/accessories specified by the manufacturer, following all relevant safety precautions for any such attachments/accessories.

8. For applicable equipment, use the included power cord with the grounding prong intact to insure proper grounding of the device.

9. If the provided plug does not fit the desired outlet, contact a licensed electrician to replace the obsolete outlet.

10. Protect any power cord from being walked on, pinched, strained, or otherwise potentially damaged, especially at the outlet or device connections.

11. Disconnect any outlet powered apparatus from its power source during lightning storms or when unused for long periods of time.

12. To completely disconnect equipment from AC mains power, disconnect the power supply cord plug from the AC receptacle on the device.

13. For any hardwired or fixed in-wall apparatus, carefully follow all wiring diagrams and instructions. All electrical wiring and servicing should be performed by a properly licensed electrician.

Savant Power® Panel Deployment Guide

009-2140-00 | 042522 - 3 -

Copyright 2022 Savant Systems, Inc

Savant Power® Panel Deployment Guide

1. Before You Begin

Read this document in its entirety before starting deployment of the product, and ensure that the following required items are available: iOS Device Running iOS 14.0 or Higher ......................................................................................................................................................................................

2. Deployment Steps

To successfully deploy a Savant Power Panel (Savant Power Modules and Director) using the Savant Power and Light app, follow the steps listed below.

This page can be used as a checklist to track progress as items are completed.

1. Install Director, Savant Power Modules, and Breakers..................................................................................................................................................................................

See

Wiring Diagrams

2. Complete On-Device Setup ....................................................................................................................................................................................................................................

See

On-Device Setup

3. Connect to Director V1 Hotspot ............................................................................................................................................................................................................................

See

Director Hotspot

4. Create Savant Power & Light Account and Home .........................................................................................................................................................................................

See

App Setup

5. Discover devices .........................................................................................................................................................................................................................................................

See

Device Discovery

6. Get Configuration from Director ...........................................................................................................................................................................................................................

See

Get Config

7. Test Circuits ...................................................................................................................................................................................................................................................................

See Test Circuits

8. Configure Breaker Panels, Add and Pair Modules ..........................................................................................................................................................................................

See

Breaker Panels

9. Configure Current Monitors and Contactors ....................................................................................................................................................................................................

See

Energy Monitoring and Contactor Linking

10. Configure Dedicated Loads and Backed Up Loads ......................................................................................................................................................................................

See

Configure Circuits

11. Configure Energy Scenes ........................................................................................................................................................................................................................................

See

Energy Scenes

12. Upload Configuration to Director .........................................................................................................................................................................................................................

See

Upload Configuration

13. Confirm System Functionality ...............................................................................................................................................................................................................................

See

Confirm System Functionality

Savant Power® Panel Deployment Guide

009-2140-00 | 042522 - 4 -

Copyright 2022 Savant Systems, Inc

Savant Power® Panel Deployment Guide

3. Gestures

The deployment of a Savant Power & Light app requires an iOS device. The following icons represent their respective gestures.

Tap Press and release (tap) a button or icon.

Press and

Hold

Swipe Left or

Right

Swipe Up or

Down

Press and hold a button or icon on the screen until a pop-up menu or other feature appears.

Press and swipe finger to the left or right.

Press and swipe finger up or down.

4. Third Party Documentation

This document assumes the installer has read all relevant 3rd party documentation. Read all manufacturer documentation for all 3rd party products in use; which may include, but is not limited to:

IMPORTANT!: For further information on 3rd party components, review the following documentation:

Schneider Fortress ESS

– eFlex Installation Manual

– Schneider Electric XW Pro inverter

– Generac Automatic Transfer Switch Manual

NOTES: For Savant Power Systems with Generator integration, locate the specific Installation & Operations manual for your generator and complete the generator installation process.

Savant Power® Panel Deployment Guide

009-2140-00 | 042522 - 5 -

Copyright 2022 Savant Systems, Inc

Savant Power® Panel Deployment Guide

5. Wiring Diagrams

It is important to ensure the Savant Power Module™ and Director are installed and wired correctly. Review the wiring diagrams below and confirm that all proper physical installation has been completed before proceeding.

IMPORTANT NOTE: Any Savant Host used with a Schneider Energy Storage System or a generator must be backed up by a Universal Power Supply

(UPS).

5.1. 120V 20A Savant Power Dual Relay Modules (GPM-QP2R20120-21)

ARC Fault Breakers

Bluetooth To

Companion Modules

Savant Director+

IMPORTANT NOTES!

– The 120V 20A Dual Relay Modules switches on and off loads A and B.

– The main electrical panel contains ARC fault breakers. See

section 3.2

for the standard non-

ARC fault breaker diagram.

– The diagram shows connections for both a plug-on neutral and pigtail neutral wire modules. Make connections according to the type of breaker being installed.

– Neutral and ground wires on both load centers must be common.

Load A Load B

The neutral on an ARC fault breaker can be either a pigtail wire, or plug-on neutral bus bar clip.

BREAKER

BREAKER

Connect a Gnd wire to each load

Savant Power® Panel Deployment Guide

009-2140-00 | 042522

Ground Bar

BREAKER

- 6 -

Copyright 2022 Savant Systems, Inc

Savant Power® Panel Deployment Guide

Standard non-ARC Fault Breakers

Bluetooth to

Companion Modules

Load A

Load B

Main Electrical Panel

Savant Director+

IMPORTANT NOTES!

– The 120V 20A Dual Relay Modules switches on and off

Loads A and B.

– The main electrical panel contains standard non-ARC fault

breakers. See section 5.2

for a diagram using ARC fault

breakers.

– Neutral and ground wires on both load centers must be common.

BREAKER

BREAKER

BREAKER

Neutral

Bar

Ground Bar

Connect a Gnd wire to each load

Neutral

Bar

Savant Power® Panel Deployment Guide

009-2140-00 | 042522 - 7 -

Copyright 2022 Savant Systems, Inc

Savant Power® Panel Deployment Guide

5.2. 240V 30A Savant Power Relay Modules (GPM-QP1R30240-21)

Savant Director+

Bluetooth to

Companion Modules

IMPORTANT NOTES!

– The 240V 30A Relay Module is used to switch loads that require 240V AC.

– A 2-pole 30 amp breaker supplies the 240V AC to the 240V

30A Relay Modules.

– Neutral and ground wires on both load centers must be common respectively.

240V AC Load

Main Electrical Panel Power Module Panel

2-POLE BREAKER

BREAKER

Neutral

Bar

L1

Ground Bar

L2

Neutral

Bar

Savant Power® Panel Deployment Guide

009-2140-00 | 042522

Neutral

Bar

Connect a Gnd wire to load

Ground Bar

Neutral

Bar

- 8 -

Copyright 2022 Savant Systems, Inc

Savant Power® Panel Deployment Guide

5.3. 240V 60A Relay Module (GPM-CP1R60240-21)

Load

240V AC

Neutral Bar

Main Distribution Panel

IMPORTANT NOTE!

– The 240V 60A Relay Module can accept up to a #4 AWG wire.

2-POLE BREAKER

STANDARD

BREAKER

STANDARD

BREAKER

Savant Power® Panel Deployment Guide

009-2140-00 | 042522

120V AC

Plug-on neutral bar

Phase A

Phase B

- 9 -

Copyright 2022 Savant Systems, Inc

Savant Power® Panel Deployment Guide

5.4. Powerlink Wiring Diagram

Main Electrical Panel

240V

Load

Bluetooth to

Companion Modules

Savant Power Director

IMPORTANT NOTES:

– The neutral wire, from the load wired through an arc fault circuit interrupter breaker, is connected to the neutral screw on the breaker.

– The neutral wire on the breaker will either be a pigtail wire, or a plug on neutral breaker connection.

– The neutral wire, from the load wired through a non-arc fault circuit interrupter breaker, is connected to the neutral bar in the panel.

– The Powerlink power supply can provide power for three Powerlink breakers.

– Two Powerlink breakers can be controlled by one

Savant Power Module:

Companion Module Panel

– Output A is wired to white low voltage wire on Powerlink breaker 1.

– Output B goes to white low voltage wire on Powerlink breaker 2.

Wire Nut Connections

POWERLINK

BREAKER

240V

LOADS

QO PL Power Supply

1 per 3, 40-60A

2-POLE BREAKERS

Neutral

Bar

To Gnd on loads

Ground Bar

To Gnd on loads

Neutral

Bar

Neutral

Bar

Ground Bar

Neutral

Bar

Savant Power® Panel Deployment Guide

009-2140-00 | 042522 - 10 -

Copyright 2022 Savant Systems, Inc

Savant Power® Panel Deployment Guide

5.5. MicroGrid Communication Wiring Diagram

MICROGRID ATS

EFLEX BATTERY MODULES

LEGEND

WIRE DETAILS:

CAT5

MODBUS TCP/IP CAT5

IP CAT 5

STATIC SIGNAL TWISTED PAIR

STATIC SIGNAL TWISTED PAIR (RETURN)

AC4: (1) #14 AWG 90C MIN

RJ45 Pinout Converter

CAN Bus Terminator + Cap

Network Switch

2 x CAN/RS485

PORTS PER

MODULE

(RJ45 jack)

5 VDC

1 2 3 4 5 6 7 8

Power

From UPS

Xanbus 1

Power

9-24VDC

TERMINATOR

From component

AC/DC power supply plugged into local receptacle

To

Home Network

Director V1

Ethernet RS232

5 VDC

Savant Power Director

CT CONNECTIONS

11+ 22+ 3- 3+ 4- 4+

CT 1 CT 2 CT 3 CT 4

TO N1 + N2 INPUT

MICROGRID ATS

Reference High-Voltage

Three-Line for CT and VT locations

TO T1 + T2

MICROGRID ATS OUT

VT CONNECTIONS

+A- +B- +C-

CT CONNECTIONS

+1- +2- +3- +4- +5- +6- +7- +8-

Wifi

+

BLE

Adapter

GPIO

Pair Test Reset

From UPS

Bottom Enclosure within Director V1

From L1 AC CB 2

IN MDP

AC 4

VT1

N G

Wire Nut

To GND +

NTRL Bar in MDP

+9- +10- +11- +12- +13- +14- +15- N/A

From L2 AC CB 2

IN MDP

PS

G

L

12VDC

+

-

UPS

Output

5V 2A

12V 2A

Director

E-Net Switch

VT2

N G

AC 4

VT Black wire is for

NEUTRAL feed

To GND +

NTRL Bar in MDP

From L2 AC CB 2

IN MDP MDP = Main Distribution Panel

Xanbus 2

10/100

Ethernet

CONEXT GATEWAY

1 3 5 7 9 11 13 15 17 19 21 23 25

2 4 6 8 10 12 14 16 18 20 22 24 26

Wires stripped from

CAT 5 cable

INVERTER

AC SYNC XANBUS

BTS JU-1

+12V

JU-2

RPO

AUX

JU-3

COM

JU-4

TS OUT

JU-5

TS IN

TERMINATOR

250mA

#18 twisted pair

Bottom Right Corner of XW Pro Inverter

Savant Power® Panel Deployment Guide

009-2140-00 | 042522 - 11 -

UTILITY

SOURCE

CONNECTIONS

N1 N2

LOAD

(UPPER)

CUSTOMER LOAD

T1

(LOWER)

T2

CONNECTIONS

MICROGRID ATS

Power and Control Tray

Auxiliary Contact

(on right side of ATS)

0 DC GROUND

194 +12VDC

23 TRANSFER

Copyright 2022 Savant Systems, Inc

Savant Power® Panel Deployment Guide

5.6. MicroGrid Three-Line Diagram

UT

N

L1

L2

MTR

N

L1

L2

M

L1

L2

L1

L2

MS

G

N

L1

L2

EXISTING UTILITY

TRANSFORMER

TO REMAIN

120/240V,

1P, 3W SECONDARY

EXISTING 200A,

120/240V UTILITY

METER TO REMAIN

EXISTING 200A,

120/240V,

2-POLE, 1Ø, 3W

SERVICE FUSED

DISCONNECT SWITCH

TO REMAIN

AC1

TAP

CT 1/2

Microgrid ATS

RXSW200A3

N1 N2

L1 L2

To MDP

To Mini PDP

G N

To MDP

To Mini PDP

L1 L2

E1 E2

CONDUCTOR SCHEDULE:

AC1: (2) #3/0 AWG 90C MIN (L1 / L2)

AC2: (2) #1 AWG 90C MIN (L1 / L2)

AC3: (2) #6 AWG 90C MIN (L1 / L2)

AC4: (1) #14 AWG 90C MIN

DC1: (2) #4/0 AWG 90C MIN (+ / -)

N1: (1) #3/0 AWG 90C MIN

N2: (1) #1 AWG 90C MIN

N3: (1) #6 AWG 90C MIN

G1: (1) #4 AWG 90C MIN

G2: (1) #6 AWG 90C MIN

G3: (1) #8 AWG 90C MIN

G4: (1) #12 AWG 90C MIN

MAX 200A MDP

120/240V, 1Ø, 3W

AC2

Inverter

XW Pro 6848

AC DC

To Director V1 and Loads G1

G

CT 3/4

T1 T2

AC1

CUSTOMER MAIN

DISTRIBUTION PANEL

(MDP)

N1

N

L1 L2

200A

AC CB 2

L1 1 L1

L2 2 L2

AC 4

120V to VT1

120V to AC/DC PS

120V to VT2

In

Director V1

To mPDP

Neut. Bar

AC OUT

INV

OUT

N3

L1 N L2

GRID

AC

CBs

1

L1 L2

L1 L2

AC 3

L1 L2

LOAD

2

L1 L2

AC IN

GRID

(AC1)

L1 N L2

G

G3

AC IN

GEN

(AC2)

L1 N L2

To mPDP

Gnd. Bar

AC 3

DC DC

DC CB

+

+

+ DC Bus

DC 1

- DC Bus

G2 N2

FROM GND+N

BARS IN ATS

N

G

To Inverter

To Director mPDP Neut. Bar mPDP Gnd. Bar

To Battery

To Inverter

Mini Power Distribution Panel (mPDP)

XW MINI PDP 865-1013-01

DC 1

-

To mPDP

Gnd. Bar G2

-

DC 1

-

To mPDP

Gnd. Bar

G2

-

Battery Module eFlex 5.4

Battery Module eFlex 5.4

Savant Power® Panel Deployment Guide

009-2140-00 | 042522 - 12 -

Copyright 2022 Savant Systems, Inc

Savant Power® Panel Deployment Guide

6. Power Source Requirements

The Savant Power System can be integrated with an automatic generator or battery storage system for a complete energy management experience. This

Deployment Guide includes instructions on how to set up your energy solution for integration either power source, but not both. Review the following notes on specifications.

Generator Physical Requirements

– IMPORTANT!: All Automatic Transfer Switches (ATS) must have Auxiliary Position-Indicating Contacts to connect to the Savant Power

Hosts GPIO terminals.

– Auxiliary Position-Indicating Contacts come standard on all commonly sold Generac Model residential ATS.

– Kohler residential ATS models RXT and RDT (600A and 400A) can be purchased as an accessory for Kohler model ATS under 600A. They can also be purchased as an accessory for ASCO ATS, and most other brands.

– When configuring an Savant Power System to work with a generator, the system needs to map the GPIO input to the ATS position. The ATS position can either be set to the Utility Grid or the Emergency Backup source. Please review the generator-specific ATS Operation & Installation manual for information on the auxiliary contact position.

Generator ATS Mapping

– The ATS position mapping is inputted using the Grid Available when ATS GPIO is Low checkbox within Tools > Energy Manager . For more information, see Section 15.3 ATS Position Mapping .

– When the auxiliary contact is closed , the ATS GPIO is Low .

– When the auxiliary contact is open , the ATS GPIO is High .

Schneider Energy Storage System

IMPORTANT!: For Schneider Energy Storage System (ESS) deployments, follow the steps listed in Appendix B: Schneider ESS and Conext MiniPDP before continuing deployment.

Savant Power® Panel Deployment Guide

009-2140-00 | 042522 - 13 -

Copyright 2022 Savant Systems, Inc

Savant Power® Panel Deployment Guide

7. On-Device Setup

7.1. Configure Savant Power Module Channels

Savant Power Module room, name, and slot number can be set by configuring the Savant Power Module using the PAIR button. See

Appendix A:

PAIR Button Functions for more information.

NOTE: New Savant Power Modules will have no names and begin at step 2.

1

TAP AND HOLD

PAIR BUTTON FOR

5 SECONDS TO

CLEAR SETTINGS

2

TAP PAIR TO

BEGIN PRE-APP

SETUP. SELECT

THE ROOM FOR

CHANNEL A

3

SELECT CIRCUIT

NAME FOR

CHANNEL A

4

CHANNEL A IS

CONFIGURED

5

SELECT ROOM

FOR CHANNEL B

6

SELECT CIRCUIT

NAME FOR

CHANNEL B

7

CHANNEL B IS

CONFIGURED

Savant Power® Panel Deployment Guide

009-2140-00 | 042522 - 14 -

8

SELECT SLOT

GROUP

9

SELECT SLOT

NUMBER

Copyright 2022 Savant Systems, Inc

Savant Power® Panel Deployment Guide

7.2. Pair Savant Power Modules

Savant Power Modules must be paired with the Director to establish Bluetooth communication.

1. For each Savant Power Module, press and hold the PAIR button for 3 seconds until the gear icon appears on the LCD screen.

1

1

CIRCUIT PO

WER

A

B

PAIR

Y

Y

120V 20A DU

AL RELA

MODULE INPUT

LOAD OUTPUT

UTOMA

HOME A

1HP MA

INPUT

B

X\CHAN

120-21

120V

AC 60Hz

120V

AC 60Hz

120V Y

TION EQUIP

-QP2R20

798A

120

120

INPUT A

YYW

W

OUTPUT

B

2

2. On the front of the Director, firmly press the PAIR button.

3. Confirm the Director is in Association Mode by the Status LED alternating between red and green continuously.

4. Pairing is complete when all Savant Power Modules have the gear icon replaced with a Bluetooth icon and the status LED of the Director is solid green. A default configuration is uploaded to the Director containing all Savant Power Modules and their location within the breaker panel.

NOTE: This process takes between 2-5 minutes.

4

Savant Power® Panel Deployment Guide

009-2140-00 | 042522 - 15 -

3

Copyright 2022 Savant Systems, Inc

Savant Power® Panel Deployment Guide

7.3. Director Hotspot (Optional)

For sites without an Ethernet connection, the Director can be used as a hotspot for the Savant Power & Light app to configure the Director:

1

1. Press and hold the Test button on the Director.

2. Once the Status LED blinks green and amber, on the iOS device navigate to Wireless Networks .

3. Connect to the wireless network titled SavantAP <DirectorUID>

Example: SavantAP 001aae469f9e0000

4. Enter the wireless network password.

NOTES:

– The default password is 12345678

– The Director UID is located on the front of the device.

2

Savant Power® Panel Deployment Guide

009-2140-00 | 042522 - 16 -

3

ESS-BLDDIRV12VT-00

ESS-BLDDIRV12VT-00

UID: 001AAF023E7E0000

Copyright 2022 Savant Systems, Inc

Savant Power® Panel Deployment Guide

8. App Setup

The Savant Power & Light app must be installed on an iOS device on the same network as the Savant Power Director. Using the app Store, search for

Savant Power & Light and tap install. When the app is downloaded, launch the app and complete the steps below:

8.1. Create a Home

1

TAP CREATE AN

ACCOUNT OR LOG IN

WITH AN EXISTING

ACCOUNT

2

FILL IN ACCOUNT DETAILS

AND AGREE TO THE USER

AGREEMENT BEFORE

TAPPING CREATE ACCOUNT

3

TAP CREATE HOME

4

NAME THE HOME AND

TAP NEXT.

Savant Power® Panel Deployment Guide

009-2140-00 | 042522 - 17 -

Copyright 2022 Savant Systems, Inc

Savant Power® Panel Deployment Guide

8.2. Add Photo

The Savant Home is represented within the Savant Power & Light app with a name and image.

1

TAP NEXT

2

SELECT AN IMAGE

FROM THE ARRANGED

PHOTOS

OR

TAP THE PLUS SIGN TO

TAKE A PHOTO OR USE AN

EXISTING PHOTO

3

TAP USE PHOTO

OR CHOOSE

Savant Power® Panel Deployment Guide

009-2140-00 | 042522 - 18 -

Copyright 2022 Savant Systems, Inc

Savant Power® Panel Deployment Guide

8.3. Discover Devices

The Savant Power & Light app will scan for all Energy and Lighting devices, including the Director and Savant Power Modules configured in On-

Device Setup .

1

TAP ON THE HOME

2

SELECT THE TYPE OF

DEVICES TO BE

CONFIGURED AND

TAP NEXT.

3

THE POWER & LIGHT

APP AUTOMATICALLY

SCANS FOR ALL

DEVICES ON THE

NETWORK.

4

IF THE DIRECTOR

HAS ALREADY BEEN

DEPLOYED

BEFOREHAND,

CHOOSE EITHER TO

GET THE CONFIG OR

CONFIGURE FROM

SCRATCH

Savant Power® Panel Deployment Guide

009-2140-00 | 042522 - 19 -

Copyright 2022 Savant Systems, Inc

Savant Power® Panel Deployment Guide

8.4. Energy Dashboard

The Dashboard appears after all devices have been discovered, or when the Savant Home is selected after initial deployment. is an overview of all configured power sources, loads, Energy Scenes and breaker panels.

A

B

C

D

A

B

C

D

E

F

Menu

Breaker Panels

Test Circuits

Power Sources

Energy

Monitoring

Energy

Management

Tap to open the Menu screen.

Quantity of breaker panels configured. Tap to

view the Breaker Panels screen.

Tap to view the Test Circuits screen.

Tap to view and configure a Power Source .

Tap to view and configure

Current Monitors

and

Contactors .

Quantity of Energy Scenes created. Tap to view

Energy Scenes

.

E

F

Savant Power® Panel Deployment Guide

009-2140-00 | 042522 - 20 -

Copyright 2022 Savant Systems, Inc

Savant Power® Panel Deployment Guide

9. Get Config

A Config is a file that contains all Savant Power Modules, breakers, their slots, power sources, and associated settings.

IMPORTANT!: The initial config must be downloaded from the Director to the Savant Power & Light app before making any changes or continuing deployment.

1

TAP THE SYNC ICON

2

TAP GET CONFIG

FROM THE HOST

3

TAP SYNC CONFIG

4

TAP OK WHEN

DOWNLOAD IS

COMPLETE

Savant Power® Panel Deployment Guide

009-2140-00 | 042522 - 21 -

Copyright 2022 Savant Systems, Inc

Savant Power® Panel Deployment Guide

10. Test Circuits

With the Config uploaded to the Power & Light app, test the functionality of the Savant Power Modules and their associated circuits before continuing deployment.

1 ON THE HOME SCREEN,

TAP TEST CIRCUITS

2 TAP THE TOGGLE

SWITCH TO TURN

INDIVIDUAL LOADS ON

OR OFF

3 TAP THE ... ICON TO

SORT CIRCUITS

ALPHABETICALLY OR BY

ROOM

Savant Power® Panel Deployment Guide

009-2140-00 | 042522 - 22 -

Copyright 2022 Savant Systems, Inc

Savant Power® Panel Deployment Guide

11. Breaker Panels

For proper functionality, ensure that the breaker panel settings match the physical specifications. The steps are identical for any type of breaker panel, save for data entered into the fields. Follow the steps below:

11.1. Add Breaker Panel

Alexis Home

1 TAP BREAKER

PANELS

2 TAP ADD PANEL 3 SELECT EITHER BLANK

PANEL, OR TEMPLATES

4 CHOOSE WHICH

POWER SOURCE WILL

PROVIDE BACKUP

POWER WHEN THE

GRID IS UNAVAILABLE

Savant Power® Panel Deployment Guide

009-2140-00 | 042522 - 23 -

Copyright 2022 Savant Systems, Inc

Savant Power® Panel Deployment Guide

11.2. Breaker Panel Settings

Refer to the manufacturers documentation to confirm the following settings are correct before uploading the configuration to the Director.

C

D

E

F

G

H

I

A

B

A

B

C

D

E

F

G

H

I

Panel Name

Panel Hierarchy

Main Breaker (Feed)

Phase Type

Name of the breaker panel as it will appear in the Power & Lighting app.

Main Distribution Panel: Panel will control distribution of power throughout the Savant Home.

Sub Panel: Panel is subordinate to a

Main Distribution Panel.

Current output from the main feed into this panel.

Quantity of phases in this panel.

Panel Size

Panel Breaker

Columns

Location

Backup Power Source

Panel Type

Quantity of slots in the breaker panel.

Quantity of columns in the breaker panel.

Room within the Savant Pro App the breaker panel is located.

Which Power Source is backing up the panel.

Make and Model of the breaker panel.

Savant Power® Panel Deployment Guide

009-2140-00 | 042522 - 24 -

Copyright 2022 Savant Systems, Inc

Savant Power® Panel Deployment Guide

11.3. Slots

A

B

E

H

I

F

G

J

K

C

D

G

H

I

Panel

A Panel Side

B Slot Number

C Empty Slot

D

Module

Model

E Menu

F Load Type Indicator

J

K

Status Indicator

Power Meter

Switch Status

Circuit Name

Display Name

Which side of the panel is being displayed.

Individual slot in the panel. Tap to test the associated load.

Tap to add a module to the slot.

User-entered breaker panel model.

Tap to change zoom level or save panel template.

Indicates whether the Savant Power Module controls a Lighting or Energy type load.

: Unpaired.

: Paired to the Director.

Real-time power consumption.

Indicates whether or not the circuit is enabled.

Name of associated circuit as it will appear in the Savant Pro app. Tap to assign or re-assign

Circuit Name.

Shorthand name for the circuit.

Savant Power® Panel Deployment Guide

009-2140-00 | 042522 - 25 -

Copyright 2022 Savant Systems, Inc

Savant Power® Panel Deployment Guide

11.4. Add Module (Optional)

The Slots screen is a list of all slots ordered by physical location on the breaker panel. Skip this section if

On-Device Setup has been completed. In

this example, a Savant Power Module will be added.

1 TAP BREAKER

PANELS

2 TAP THE CONFIGURED

PANEL

3 TAP AN EMPTY SLOT 4 SELECT THE MODULE

TYPE

NOTE: To remove an existing module, tap the device icon and then tap Delete Device .

Savant Power® Panel Deployment Guide

009-2140-00 | 042522 - 26 -

Copyright 2022 Savant Systems, Inc

Savant Power® Panel Deployment Guide

Pair Added Savant Power Module (Optional)

Once a Savant Power Module has been added, it must be paired to the Director to establish communication.

1

TAP PAIR

Savant Power® Panel Deployment Guide

009-2140-00 | 042522

2 TAP THE PAIR BUTTON ON

AN INCHARGE MODULE TO

CAUSE IT TO FLASH IN THE

POWER & LIGHT 2.0 APP

OR

TAP IDENTIFY IN THE APP

TO TURN THE INCHARGE

MODULE AND ASSOCIATED

LOAD ON AND OFF

3

SELECT THE MODULE

AND TAP PAIR

4 THE INCHARGE MODULE

WILL DISPLAY A

BLUETOOTH ICON WHEN

PAIRED

Copyright 2022 Savant Systems, Inc

- 27 -

Savant Power® Panel Deployment Guide

11.5. Assign Circuit Name (Optional)

Names configured during On-Device Setup

are displayed. To change the circuit name, follow the steps below..

1 TAP ASSIGN CIRCUIT NAME 2

SELECT THE ROOM THE

CIRCUIT PROVIDES ENERGY

TO AND TAP SAVE ROOM

3

SELECT THE SPECIFIC

CIRCUIT THE CHANNEL

POWERS AND TAP ASSIGN

CIRCUIT

4

THE CHANNEL WILL

APPEAR NAMED WHEN

COMPLETE

Savant Power® Panel Deployment Guide

009-2140-00 | 042522 - 28 -

Copyright 2022 Savant Systems, Inc

Savant Power® Panel Deployment Guide

12. Energy Monitoring

The Savant Energy Monitor (SEM) and Current Transformers (CTs) are used to monitor power of the main feed, grid power, and loads in the home that are greater than 60A.

12.1. VT and CT Placement

Voltage Transformers (VT) and Current Transformers (CT) are used to monitor Voltage and Current respectively. Review the following tables for correct placement.

Savant Power System with Generator

SEM CT

1 / 2

3 / 4

Physical Connection

ATS Normal Input

ATS Emergency Input

Circuit Name

Grid Feed

Generator Power

CT Size

250A

150A

Classification

Feed

Production

Savant Power System with Schenider ESS

SEM CT

1 / 2

3 / 4

Physical Connection

ATS Input

ATS Output

Circuit Name

Grid Feed

Total Consumption

CT Size

250A

150A

Classification

Feed

Total Consumption

Savant Power® Panel Deployment Guide

009-2140-00 | 042522 - 29 -

Copyright 2022 Savant Systems, Inc

Savant Power® Panel Deployment Guide

12.2. Configure Current Monitors

To for live data for loads greater than 60A to display correctly, Current monitors must be assigned to the correct panel, size and channel.

Circuit Panel and Slots

In this configuration, a car charger will be configured to be monitored by a 50A Savant Energy Monitor.

1

TAP ENERGY

MONITORING

2

TAP SETUP CURRENT

MONITORS. THEN

SELECT A CIRCUIT

CLASSIFICATION AND

TAP NEXT.

3

TAP THE PANEL TO

BE MONITORED AND

TAP NEXT.

Savant Power® Panel Deployment Guide

009-2140-00 | 042522 - 30 -

Copyright 2022 Savant Systems, Inc

Savant Power® Panel Deployment Guide

Circuit Name and Group

Circuit names and groups are the visual representation of the circuit within the Savant Pro App.

5

ENTER THE CIRCUIT

NAME AND TAP NEXT.

6 TAP IMAGE 7 SELECT AN IMAGE

THAT WILL REPRESENT

THE CIRCUIT

8

TAP ROOM AND CHOOSE

A ROOM WITHIN THE

CONFIGURATION OR

CREATE A NEW ONE.

REPEAT STEPS 5

THROUGH 8 FOR CIRCUIT

GROUPS

Savant Power® Panel Deployment Guide

009-2140-00 | 042522 - 31 -

Copyright 2022 Savant Systems, Inc

Savant Power® Panel Deployment Guide

Current Sensor Size and Channel

Current sensor size and channel must match the specifications of the installed current sensor.

5 SELECT THE CURRENT

SENSOR SIZE. TAP NEXT.

TAP SHOW MORE SENSORS

FOR ALL SUPPORTED

SENSOR SIZES

6 TAP SELECT CHANNEL

NEXT TO L1, SENSOR A

7 SELECT THE CHANNEL

WIRED TO L1, SENSOR A.

8 REPEAT THIS PROCESS FOR

CHANNEL 2 AND TAP NEXT.

Savant Power® Panel Deployment Guide

009-2140-00 | 042522 - 32 -

Copyright 2022 Savant Systems, Inc

Savant Power® Panel Deployment Guide

12.3. Channel Settings

B

A

C

D

E

F

G

H

I

J

K

L

M

Savant Power® Panel Deployment Guide

009-2140-00 | 042522 - 33 -

Current Channel

A Channels

B Live Data

C Invert

Required Settings

D Classification

E Circuit

F Current Monitors

G

H

VT Connections

Room

I Image

N

O

P

J Current Size

K Image

L

Current Transformer

Size

Optional Settings

M Group

Group Image

Parent Circuit

Contactor

All associated channels.

– Selected channel is outlined.

– Blue channels are configured.

– Grey channels are unconfigured.

Live data sorted by individual channel.

Tap to invert live data values.

Whether the CT channel is Consumption,

Feed, or Main.

The selected circuit used to monitor energy consumption.

Quantity of Current Monitors and which channel is monitoring which slots.

Quantity of voltage sensors and which slots they are linked to.

Room within the config

Image representing the Savant Power

Module and Channels within the Savant

Pro App

Total amps the

The icon that the channel will be represented as in the Pro app.

Tap to assign transformer size (in Amps).

Which group these channels will be associated with.

Image associated with the group.

Tap to assign a Parent Circuit.

Tap to link selected channels to a Savant

Power Module.

Copyright 2022 Savant Systems, Inc

Savant Power® Panel Deployment Guide

12.4. Contactor Linking

Loads greater than 60A are controlled using a Savant Power Module Control Relay + Contactor, and monitored by the Savant Energy Monitor

(SEM). Contactor Linking is required within the Savant Power & Light app to link the Current Transformer (CT) to the Savant Power Module channel communication, it is important to configure the gateway to have a reserved IP address.

4

TAP SETUP CONTACTOR

AND TAP NEXT.

5

TAP THE COMPANION

MODULE CONTROLLING

THE CONTACTOR THEN

TAP NEXT.

6

THE APP WILL LINK

THE CONTACTOR TO

THE CIRCUIT. TAP GOT

IT WHEN DONE.

Savant Power® Panel Deployment Guide

009-2140-00 | 042522 - 34 -

Copyright 2022 Savant Systems, Inc

Savant Power® Panel Deployment Guide

12.5. Add Power Source

Power sources are devices wired to provide auxilliary power to the Savant Home. Add power source within the Power & Light app by following the steps below. In this example, a Battery is chosen.

I MPORTANT NOTES!:

– The Director must be connected to the main network for all further steps.

For Savant Power Systems integrating a Schneider Energy Storage System, see Appendix B: Schneider ESS and Conext MiniPDP

before completing this section.

– For a battery power source, both the Director and battery gateway must both be on the same subnet.

1 TAP POWER SOURCES 2

TAP THE PLUS SIGN TO

CREATE A NEW POWER

SOURCE

3

SELECT THE POWER

SOURCE AND TAP NEXT

4

ENTER GENERAL

SETTINGS AND TAP

NEXT

5

CHOOSE WHICH

BREAKER PANEL TO

BACK UP AND TAP NEXT

Savant Power® Panel Deployment Guide

009-2140-00 | 042522 - 35 -

Copyright 2022 Savant Systems, Inc

Savant Power® Panel Deployment Guide

12.6. Configure Power Source (Optional)

Once the power source has been added, its settings can be configured. The process to configure settings is the same regardless of type, however the settings are different.

5

WITHIN THE POWER

SOURCES SCREEN, SWIPE

LEFT OR TAP ON THE

EDIT ARROW

Savant Power® Panel Deployment Guide

009-2140-00 | 042522

6

TAP THE PENCIL ICON

NOTE: TAP THE TRASHCAN

ICON TO REMOVE POWER

SOURCE

7

CONFIGURE ALL

BATTERY SETTINGS AS

LISTED ON NEXT PAGE

AND TAP NEXT

Copyright 2022 Savant Systems, Inc

- 36 -

Savant Power® Panel Deployment Guide

12.7. Power Source Settings

Generator Settings

IMPORTANT!: Before completing all fields in power source settings, see Generator Considerations and Whole Home Backup for term clarification.

D

E

F

G

A

B

C

General Settings

A Start Timeout

B

C

Host on UPS

Backup

Whole Home

Backup

ATS Controller Settings

D ATS Controller

E

F

G

Length of time before the generator is consider to have failed starting up.

Total capacity of the battery in kilowatt per hour.

Inverter capacity in kilowatts per hour.

ATS Controller

Port

ATS on Grid

Position

ATS on Backup

Position

IP address and port of the Conext gateway as reserved in Appendix

B: Schneider ESS and Conext

MiniPDP.

Port of the Conext gateway as reserved in Appendix B:

Schneider ESS and Conext

MiniPDP .

Which position dictates the

Savant Power System has access to the grid.

Which position dictates the

Savant Power System does not have access to the grid.

Savant Power® Panel Deployment Guide

009-2140-00 | 042522 - 37 -

Copyright 2022 Savant Systems, Inc

Savant Power® Panel Deployment Guide

Battery Settings

A

D

E

F

B

C

G

H

Savant Power® Panel Deployment Guide

009-2140-00 | 042522 - 38 -

General Settings

A Name

B

C

D

E

Battery Inverter

Type

Battery Capacity

(kWh)

Battery Inverter

(kW)

Host on UPS

Backup

F

Whole Home

Backup

Controller Settings

G IP Address

H Port

Name as it will appear in the

Savant Power & Light app and

Savant Pro app.

Total capacity of the battery in kilowatt per hour.

Inverter capacity in kilowatts per hour.

Whether the Host is backed up by UPS or not.

Whether the entire hme is backed up by the power source or not.

IP address and port of the Conext

gateway as reserved in Conext

Gateway Setup

.

Port of the Conext gateway as reserved in Conext Gateway

Setup .

Copyright 2022 Savant Systems, Inc

Savant Power® Panel Deployment Guide

Microgrid Settings

J

K

G

H

I

A

B

C

D

E

F

Savant Power® Panel Deployment Guide

009-2140-00 | 042522 - 39 -

General Settings

A

B

C

Name

Controller Type

IP Address

D Port

E

F

Host on UPS

Backup

Whole Home

Backup

Battery Settings

G

Battery Inverter

Type

H Battery Capacity

I

Battery Inverter

(kW/h)

Generator Settings

J

Output Power

(kW)

Solar Settings

K

Name as it will appear in the

Savant Power & Light app and

Savant Pro app.

Which type of controller will control the Microgrid.

IP address and port of the Conext

gateway as reserved in Conext

Gateway Setup

.

Port of the Conext gateway as reserved in Conext Gateway

Setup .

Whether the Host is backed up by UPS or not.

Whether the entire home is backed up by the power source or not.

Type of battery inverter

Total capacity of the battery in kW.

Maximum kW/h the battery inverter can supply.

Maximum kW the generator can produce.

Copyright 2022 Savant Systems, Inc

Savant Power® Panel Deployment Guide

13. Circuits

13.1. Dedicated Circuit

For proper Energy Scene functionality, dedicated loads and their max wattage must be defined. A dedicated circuit is a circuit that serves a single appliance or electrical fixture. No other loads are allowed to draw energy from a dedicated circuit. See the following table for examples of circuit classification for a 200 Amp service size home as a guide.

Examples of Circuit Classification for a 200A Service Size Home

Dedicated Circuits

– Kitchen Small appliance Circuit

– Sewer Ejection Pump Outlet

– Microwave

– Electric Cooktop

– Electric Range

– Fridge

– Electric Dryer

– Dining Room Outlets

– Garage Door Opener(s)

– Bathroom GFCI Outlet(s)

– Smoke Detectors (Bedroom)

– Basement Freezer

– Garage Outlet(s)

– Car Charger

– Basement Sump Pump

– Well Pump

– Furnace Air Handler

– AC Condenser

– Washing Machine Outlet

– Electric Water Heater

– Dishwasher

Non-Dedicated Circuits

– Living Room Lights

– Living Room and Hall Outlet(s)

– 2nd Floor East Bedroom Lights and Outlets

– Bathroom and Hall Lighting

– Kitchen Lighting

– Basement Light(s)

– 2nd Floor West Bedroom Lights and Outlets

– Garage and Mudroom Lights

– Master Bedroom Lights and Outlets

– Master Bath Lighting

– Foyer and Outdoor Lighting

Savant Power® Panel Deployment Guide

009-2140-00 | 042522 - 40 -

Copyright 2022 Savant Systems, Inc

Savant Power® Panel Deployment Guide

13.2. Configure Circuits

To configure dedicated loads and loads backed up by the the power source configured in section 11.5

, complete the following:

Alexis Home

1 TAP TEST CIRCUITS 2

TAP DEDICATED

AND SELECT ALL

DEDICATED LOADS

3

TAP MAX WATTAGE

AND ENTER

MAXIMUM WATTAGE

FOR DEDICATED

LOADS

4

TAP BACKUP

TO VIEW AND EDIT

WHICH LOADS ARE

BACKED UP BY A

CONFIGURED POWER

SOURCE

Savant Power® Panel Deployment Guide

009-2140-00 | 042522 - 41 -

Copyright 2022 Savant Systems, Inc

Savant Power® Panel Deployment Guide

14. Energy Scenes

Energy Scenes are commands configured within the Savant Power & Light app. Energy Scenes determine which loads will be enabled if a power outage occurs.

14.1. Create Energy Scene

In this example, an Off Grid Energy Scene is created. An Off Grid Scene will automatically activate in the event of a power outage. Off Grid Scenes set which loads will remain powered (critical) when the system switches to backup power. Additional scenes can be created and configured to trigger based on battery state of w or on a schedule. The default Essentials Off Grid Scene will automatically activate in the event of a power outage.

1 TAP ENERGY

MANAGEMENT

2

TAP THE PLUS SIGN

TO CREATE A NEW

SCENE

3 SELECT AN

OFF GRID SCENE

4

CONFIGURE SCENE

SCHEDULE AND TURN

CONDITIONS AND TAP

NEXT

IMPORTANT!:

– If two scenes have the same battery and grid conditions are scheduled to occur at the same time, the scene that satisfies more specific conditions is run.

– If the battery state of charge reaches a level that exists in an Off Grid Scene condition while the grid is down, that particular Off Grid Scene will activate.

– If the battery state of charge has reached a level that exists in an Off Grid Scene condition when the grid goes down, that particular Off Grid will activate.

– On The Grid scenes can be used at any time and will be implemented in a future release.

Savant Power® Panel Deployment Guide

009-2140-00 | 042522 - 42 -

Copyright 2022 Savant Systems, Inc

Savant Power® Panel Deployment Guide

14.2. Energy Budget

The energy budget is a percentage of the maximum kW the power source can provide. This is handled automatically by the Power & Light app when the energy budget is given for an off grid scene. This section is informational.

– If the battery inverter or generator size is less than or equal to 10kW , the energy budget for off grid scenes is equal to the size of the inverter or generator.

– If the battery inverter or generator size is greater than 10kW , calculate the energy budget using the following equation:

Budget = Power Source Size + ( Power Source Size - 10kW / 0.4).

Example: A battery inverter has a size of 13.6 kW . The following equations represent calculating its energy budget.

Energy Budget = 10kW + (13.6 kW - 10kW)/0.4

Energy Budget = 10kW + 3.6kW/0.4

Energy Budget = 10kW + 9kW

Energy Budget = 19kW .

Savant Power® Panel Deployment Guide

009-2140-00 | 042522 - 43 -

Copyright 2022 Savant Systems, Inc

Savant Power® Panel Deployment Guide

14.3. Edit Scene Loads

This window is a visual representation of all of the loads that will be available while the scene is enabled. When a load is unchecked, the load will be unavailable while the Scene is active. Tap Done to finish Energy Scene creation.

NOTES:

– Only configured and detected loads will be visible on this screen.

– Only dedicated loads need to be selected on this screen. Non-dedicated loads will remain available for any off grid scene.

Savant Power® Panel Deployment Guide

009-2140-00 | 042522 - 44 -

Copyright 2022 Savant Systems, Inc

15. Upload Configuration

Once all changes have been made to the configuration, it must be uploaded to the Director.

1 TAP SYNC CONFIG 2 TAP SAVE THE CONFIG TO

THE HOST

3

TAP SYNC CONFIG. THE

GREEN CIRCLES INDICATE

THE CONFIGURATION IS

BEING UPLOADED

4 TAP OK WHEN THE UPLOAD

IS COMPLETE

Savant Power® Panel Deployment Guide

009-2140-00 | 042522 - 45 -

Copyright 2022 Savant Systems, Inc

Savant Power® Panel Deployment Guide

16. Confirm System Functionality

Once the configuration is synced to the Director, the configuration is complete. However, it is important to test the system to ensure correct functionality.

1. Check that All Circuits are Named Correctly on Savant Power Module Display ................................................................................................

2. Confirm that Circuit Power Readings appear Correctly on Savant Power Module Display ...........................................................................

3. Ensure that All Circuits can be Powered On and Off from the Savant Pro app .................................................................................................

4. Check that All Loads Report Energy Readings Properly in the Savant Pro app ................................................................................................

5. Check that Total Consumption, Battery, and Grid Power are Reported Properly in the Savant Pro app .................................................

6. Take the System Off the Grid and Check that the appropriate Off Grid Scene Triggers ................................................................................

7. Test all Configured Off-Grid Scenes — Check that the Load States are Set Accordingly ..............................................................................

8. Bring the System Back onto the Grid and Check that All Loads are Restored ...................................................................................................

Savant Power® Panel Deployment Guide

009-2140-00 | 042522 - 46 -

Copyright 2022 Savant Systems, Inc

Savant Power® Panel Deployment Guide

Appendix A: Savant Power Module PAIR Button Functions

The PAIR button on Savant Power Modules has multiple functions depending on the length of time pressed.

– To cycle through options, tap the PAIR button.

– To select an option, hold the PAIR button for 1 second.

– To clear pairing, hold the PAIR button for 3 seconds until the Gear icon appears.

– To reset the Savant Power Module, hold the PAIR button for 5 seconds.

1

CIRCUIT PO

WER

A

B

PAIR

Y

Y

X\CHAN

120-21

:

120V 20A DU

GPM-QP2R20

MODULE INPUT

:

120V

120V

:

AC 60Hz

AC 60Hz

120V

AC 20A/

Y

1HP MA

120

120

#12-8 A

HOME A

UTOMA

798A

-QP2R20

INPUT B

INPUT A

YYW

W

OUTPUT

B

OUTPUT

A

Savant Power® Panel Deployment Guide

009-2140-00 | 042522 - 47 -

Copyright 2022 Savant Systems, Inc

Savant Power® Panel Deployment Guide

Appendix B: Schneider ESS and Conext MiniPDP

Schneider Energy Storage Systems (ESS) require communication to be established between Director and Conext Gateway. To facilitate this communication, it is important to configure the gateway to have a reserved IP address.

Schneider Conext MiniPDP Labeling

The Schneider Conext MiniPDP ships with incorrect labeling. Review the image to the right for correct labeling.Schneider Conext Gateway Setup

AC IN AC OUT INVERTER IN

(GRID)

INVERTER

DISCONNECT

1

00:77:FF:84:D1:50

Software Version

V1.08BBN415

Wifi Password

3a0a7fb335c8c

BC21135002412

MANUFACTURED

07/Dec/21

Reserve Schneider Conext Gateway IP Address

1. Locate the MAC address of the Schneider Conext Gateway and note it down.

NOTE: The MAC address is located on the rear of the unit.

2. Find the make of the router installed and download the respective app. In this example, an eero router is used.

3. Create an account and log into the eero application.

Savant Power® Panel Deployment Guide

009-2140-00 | 042522 - 48 -

Copyright 2022 Savant Systems, Inc

Savant Power® Panel Deployment Guide

4 SELECT SETTINGS TAB 5 TAP NETWORK

SETTINGS

8. Tap the Unnamed Device and enter the desired IP address.

9. Tap and reboot the Conext gateway.

6 TAP RESERVATIONS

& PORT

FORWARDING

7 SEARCH FOR

“SCHNEIDER CONEXT

GW” MAC ADDRESS

Savant Power® Panel Deployment Guide

009-2140-00 | 042522 - 49 -

Copyright 2022 Savant Systems, Inc

Savant Power® Panel Deployment Guide

Appendix C: System Information Checklist

This page is used to record all important information for the installation.

Site Information

Date of Deployment:

Site WiFi SSID:

Site WiFi Password:

Schneider Information

WiFi Password:

MAC Address:

Serial Number:

Software Version:

MFG:

Fortress Information

Battery Install Date:

Savant Information

Bootloader:

Firmware Version:

Savant Power & Light Build:

Savant Pro app Version:

NOTES:

Savant Power® Panel Deployment Guide

009-2140-00 | 042522 - 50 -

Copyright 2022 Savant Systems, Inc

Savant Power® Panel Deployment Guide

Important Notice

Disclaimer

Savant Systems, Inc. reserves the right to change product specifications without notice, therefore, the information presented herein shall not be construed as a commitment or warranty.

Savant Systems, Inc. shall not be liable for any technical or editorial errors or omissions contained herein or for incidental or consequential damages resulting from the performance, furnishing, reliance on, or use of this material.

Patents

Certain equipment and software described in this document is protected by issued and pending U.S. and foreign patents.

All products and services are trademarks or registered trademarks of their respective manufacturer.

Coypright

This document contains confidential and proprietary information protected by copyright. All rights reserved. Copying or other reproduction of all or parts of this document is prohibited without the permission of Savant Systems.

Trademarks

© 2022 Savant Systems, Inc. All rights reserved. Savant, Savant app, TrueImage, Savant Host, Now You Can, RacePoint Blueprint, Single app Home,

TrueCommand, TrueControl, and the Savant logo are trademarks of Savant Systems, Inc.

AirPlay, apple, AirPort Express, AirPort Extreme, apple TV, apple Remote Desktop, FireWire, iMac, iTunes, iPad, iPad mini, iPad Air, iPhone, MacBook, Mac and OS X are trademarks or trade names of apple Inc. iOS is a trademark of Cisco®. Android, Google, Google Play, and other Google marks are trademarks of Google, Inc. Wi-Fi is a registered trademark of the Wi-Fi Alliance®. HDMI® is a trademark of HDMI Licensing, Inc. MOTU® is a registered trademark of

Mark of the Unicorn, Inc. Luxul is a registered trademark of Luxul Wireless. NETGEAR®, the NETGEAR Logo and ProSAFE are trademarks of NETGEAR, Inc.

Extreme™ is a trademark of Extreme Networks, Inc.

All other brand names, product names, and trademarks are the property of their respective owners.

Technical and Sales Support

Savant Power, Inc. is dedicated to providing prompt and effective support in a timely and efficient manner.

– To contact Savant Power Support, access the Savant Customer Community and enter a support Case ticket.

– To contact Savant Sales, visit Savant.com and select Contact Us to locate a local sales representative in your area.

Savant Power® Panel Deployment Guide

009-2140-00 | 042522 - 51 -

Copyright 2022 Savant Systems, Inc

advertisement

Related manuals

Download PDF

advertisement