Descriptions Box Contents
(1) 240VAC (2 Pole) Relay Companion Module
– GPM-QP1R30240-21 QO™ w/Plug-on Neutral
– GPM-Q1R30240-21 QO™ w/Pigtail Neutral
(1) Product Information and Regulatory Insert (009-1950)
(1) Quick Reference and Installation Guide (this document)
Specifications
Environmental
Temperature 32° to 104° F (0° to 40° C)
Humidity 5% to 85% Relative Humidity (non-condensing)
Location Indoor Use Only
Dimensions and Weights (net)
Module
Shipping
Length
4.97 in.
(12.63 cm)
7.50 in.
(19.05 cm)
Width
1.45 in.
(3.68 cm)
4.30 in.
(10.92 cm)
Power
Input Power
(powers the module)
Input Power
(from feeder breaker)
Height
2.60 in.
(6.61 cm)
1.71 in.
(4.34 cm)
Weight
.5 lbs
(.23 kg)
1.0 lbs.
(.45 kg)
120V AC (+/- 10%) @ 60 Hz, 0.1A (max)
240V AC @ max load power
Load Power
7200VA
(240VAC 30A resistive load / 2HP max)
Features of Automatic
Action
Type 1.B action
Standards
Wireless
Bluetooth Low Energy (BLE)
– 2.4 GHz radio frequency
Regulatory
FCC Part 15 UL ICES 003
Safety and Emissions
A
B
C
D
E
A
B
F
DO NO
T
SCREEN
REMO
ALLA
CIRCUIT PO
TION
WER
ON
AUT
O
D
PAIR
G
C
Y
Y
INDOO
R USE ONL
X
240 120V
AC 60Hz
240V 30A 2-POLE RELA
Y
30A/
2HP MA
#10-8 A
WG Cu ONL
TION EQUIP 240
IC ID: 10
798A
-QP1R30
240
INPUT L1
YYW
W
OUTPUT
L1
E
Multi-Page LCD screen that can display the following:
– Power draw at the output.
– Firmware, Mac Address, and Regulatory Info.
– UID of the Host the module is communicating with.
– Real-time Bluetooth status connectivity icon.
Manual Load Switch - Toggle to the ON position to switch the load on. Toggle to AUTO for normal operation.
PAIR Button - The PAIR button is a multi-use button. The duration that the button is pressed and held determines the function that gets initiated:
Press and Release - Cycles through the various screens available on the LCD (POWER > ENERGY > INFO 1 > INFO 2).
Press and hold - Press and hold for 2 seconds to put module into pairing mode. Press and hold for 5 seconds to reset.
Input Power Connections - Connect outputs from two breakers to inputs L1 and L2 on the module. See the
section below.
Output Power Connections - Connect a 240V AC load across
outputs L1 and L2. See the Wiring
section below.
Contains FCC ID:
Contains IC:
PUU-QP1R30240
10798A-QP1R30240
RoHS Compliant
Recommended Load Center Types
Refer to the Features section to the right for compatibility.
Supported Load Types
Standard Configuration Relay On/Off type loads (home automation)
Electrical and Safety Characteristics
Screw Tighten Torque 3.0 Nm
Wire Type
Pollution Degree
Purpose of Control
Software
Impulse Voltage
Construction of Control
Copper (Cu) only
2
Operating Control, Smart Relay Control
Module or the equivalent
Class A
2500V
Open Type Independently mounted for flush mounting
Minimum Supported Release
Savant OS da Vinci 10.1
Single 30 Amp Relay Companion Module - QRG | 009-2112-02
Copyright ©2022 Savant Systems, Inc | 220408
F
G
120V AC Connection - Plugs into the 120V AC bus bar in the breaker panel. The voltage on this connection powers the module.
Neutral - The model number of the module determines the type of neutral connection on the module:
– Plug-On Neutral - Positioned on the bottom of the module is a neutral clip that plugs directly onto the neutral bar.
– Pigtail Neutral - A neutral wire protrudes from the module’s rear and gets wired to the neutral bar in the breaker panel.
Features
– Control capability for loads up to 7200 VA (volt-ampere).
– The GPM-QP1R30240-21 and GPM-Q1R30240-21 30A Relay
Companion Modules are compatible with Schneider Electric/Square
D™ QO™ load centers.
– Dynamic management of loads.
– Built-in energy monitoring; +/- .5% revenue grade accuracy / 1 sec sample time.
– Communicates over the air using Bluetooth Low Energy (BLE) technology.
– Manual load switch on the front panel can toggle power to the output On and Off.
– Color LCD display for easy identification and load status.
1 of 4 45 Perseverance Way, Hyannis MA 02601
Savant.com
| 508.683.2500
Important Information
– The breaker(s) feeding this module should not be larger than 30 amps.
– This relay module can handle loads up to 30 amps.
– To determine the number of breaker panel spaces needed, add the number of spaces required for the circuit breakers with the spaces needed for the module.
• A single pole circuit breaker requires 1 space.
• A 2-pole circuit breaker requires two spaces.
• Each Companion Module requires two spaces.
– Savant recommends not connecting any mission critical loads such as medical devices to this relay module.
ELECTRIC SHOCK!
The 120/240V AC, 60 Hz source poses an electrical shock hazard that has the potential to cause serious injury to installers and end users.
CAUTION!
Risk of Electric Shock - More than one disconnect switch may be required to de-energize the device before servicing.
IMPORTANT!
A licensed electrician is required to install any of
Savant’s Relay Companion Modules.
Branch Circuit Minimum Size of Conductors
(General circuit wiring, Copper Conductors)
15A 20A 30A 40A 50A 60A
#14 AWG #12 AWG #10 AWG #8 AWG #6 AWG #4 AWG
NOTE: This wiring requirement was based on the National Electric Code
(NEC) (ANSI/NFPA70), Canadian Electric Code, Part 1 (CEC), and local codes Minimum Size of Conductors.
Installation into Breaker Panel
1. Remove power from the breaker panel by switching off the panel’s main breaker.
2. Position and install a 2-pole breaker into any two slots in the breaker panel. Press firmly until the breaker is fully seated onto the appropriate bus bars.
3. Position and install the Companion Relay Module into any two empty slots in the breaker panel. Press firmly until fully seated onto the appropriate bus bar. This module is typically installed alongside the 2-pole breaker installed in step 2 but doesn’t need to be.
HELPFUL!
This relay module fills two slots in the breaker panel but connects to only one phase (120V AC). See diagrams below.
4. Use the diagrams below and make the appropriate connections. The diagram on the left is for the modules that contain a plug-on neutral clip. The diagram on the right is for modules that include a neutral wire.
Wiring
Use the diagrams below when wiring the modules
Wiring with Plug-on Neutral
Neutral Bar
Wiring with Pigtail Neutral
Companion Module with Plug-on Neutral
Neutral Bar
Companion Module with Pigtail Wire for the Neutral
120V AC
NOTE: The companion module connects to just one phase.
The 2-pole breaker connects to both phases.
2-POLE BREAKER
STANDARD
BREAKER
STANDARD
BREAKER
NOTE: The companion module connects to just one phase.
The 2-pole breaker connects to both phases.
2-POLE BREAKER
STANDARD
BREAKER
STANDARD
BREAKER
240V AC
Load
Plug-on neutral bar
120V AC
Phase A
Breaker Panel
Phase B
240V AC
Load
Phase A
Breaker Panel
Phase B
IMPORTANT!
When making connections, observe all general electrical best practices which includes the local wire sizing guideline codes.
See the Branch Circuit Minimum Size Conductors table above.
Single 30 Amp Relay Companion Module - QRG | 009-2112-02
Copyright ©2022 Savant Systems, Inc | 220408
2 of 4 45 Perseverance Way, Hyannis MA 02601
Savant.com
| 508.683.2500
Circuit Test Instructions
Use the instructions below to test the relay modules. The setup requires:
– 30 Amp Relay Companion Module.
– Load with maximum amperage of 30A.
– Standard 2-pole, 30 amp circuit breaker.
– Breaker test panel. The type of module determines the type of breaker panel (plug-on neutral or not).
– 120/240V AC source
IMPORTANT!
– The 2-pole breaker connects across both phases in the breaker panel. The module, however, attaches to only one phase. This is shown in the image below.
– The GPM-QP1R30240-21 and GPM-Q1R30240-21 modules can accept up to a #10 AWG wire. See the Branch Circuit Minimum Size of
Conductors table on the previous page.
1. Plug the 240V AC 2-Pole Companion Module and 30 amp 2-pole feeder breaker into the circuit breaker test panel.
2. Connect the output from one of the breakers on the 2-pole breaker to the L1 input on the module.
3. Connect the output from the remaining side of the 2-pole breaker to the L2 input on the module.
4. Connect one side of a load to the L1 output on the module.
5. Connect the remaining side of the load to the L2 output on the module.
6. Apply power to the breaker panel (not shown in diagram)
7. Toggle the 30 amp 2-pole breaker to On.
8. To test, toggle the CIRCUIT POWER switch to the ON position and observe the load switches On. Toggle the CIRCUIT POWER switches to AUTO and verify the load switches Off.
Neutral Bar
The companion module connects to only one phase. The 2-Pole breaker connects to both phases
1
120V AC standard
2-pole breaker
120V AC
5
4
2
3
240V AC
240V AC
8
7
Plug-on Neutral Bus Bar
Load
Additional Documentation
Further information is available in the documents listed below and can be accessed via the Savant Customer Community .
– Panel Bridge Controller with PoE (PBC-P1000) QRG
– Savant Panelized Lighting Deployment Guide.
Single 30 Amp Relay Companion Module - QRG | 009-2112-02
Copyright ©2022 Savant Systems, Inc | 220408
3 of 4 45 Perseverance Way, Hyannis MA 02601
Savant.com
| 508.683.2500
Notes
Single 30 Amp Relay Companion Module - QRG | 009-2112-02
Copyright ©2022 Savant Systems, Inc | 220408
4 of 4 45 Perseverance Way, Hyannis MA 02601
Savant.com
| 508.683.2500
advertisement