VSP 516 User Manual V1.5

Add to my manuals
48 Pages

advertisement

VSP 516 User Manual V1.5 | Manualzz

VSP 516 Series User Manual

RGBlink Science & Technology Co., Ltd.

The pictures and data in the user manual are reference only, check the real product please!

CONTACT US

Headquarter: S603 Weiye Building Torch Hi-Tech Industrial Development Zone

Xiamen,Fujian Province, P.R.C

Shenzhen office: Room A05, Floor 4, Building 24, Industry factory Nanshan

Science & Technology Park, Shenzhen, Guangdong Province, P.R.C

Tel: +86-592-5771197 Fax:+86-592-5771202

E-mail:[email protected] http://www.rgblink.com

Revision

Format Time ECO# Description Principal

1.0

1.1

2010-1-15 0000

2010-3-11 0001

Release Lisa

Compare table of AVDSP Lisa

1.2 2010-7-20 0002

1.Add more supported output resolutions; Page:4

2.Add the adjustable feature of

DE;Page:11-12

3.Explain the limits of scale;

Page:14

0003 Add prompt to save function

Lisa

1.3 2010-8-9

1.4 2010-10-22 0004 1.Compared to VSP516 and

VSP516H, VSP516S can install

SDI input module;

2. VSP516S Baud Rate is 115200, while VSP516 and VSP516H is

9600;

3. The User’s Manual add the instruction on how to use USB port to work with console software and LINSN software.

1.5 2010-11-4 0005 Add a note about how to use LINSN

Software.

Lisa

Lisa

Lisa

CONTENT

1.0 Safety ........................................................................................... 1

2.0 Specification .................................................................................. 2

2.1 Parameters............................................................................... 3

3.0 Connection .................................................................................... 5

3.1 VSP 516 Back Panel................................................................... 5

3.2 How to install ........................................................................... 7

4.0 Front Panel Keyboard Operation........................................................ 8

4.1 VSP 516 series Operator Guideline............................................... 8

4.2 Video Processor Menu ...............................................................11

5.0 Communication Software Guideline ..................................................17

5.1 Install Software .......................................................................17

5.2 Run AVDSP Console..................................................................21

6.0 FAQ .............................................................................................31

6.1 No output in target display ........................................................31

6.2 VGA input could not work with AVDSP Console .............................31

6.3 DVI input could not work with AVDSP..........................................31

6.4 Component input could not work with AVDSP ...............................32

6.5 User settings can not save.........................................................32

6.6 Can’t update main board software ..............................................32

7.0 Quick Start ...................................................................................33

7.1 Single-screen control ................................................................33

7.2 How to control processor with console software by USB?................35

7.3 How to Use LINSN Ledset software?............................................39

8.0 Appendix ......................................................................................41

8.1 AppendixⅠDownload the IP software ..........................................41

8.2 Appendix Ⅱ How to add tasks. ...................................................43

1.0 Safety

The general safety information in this summary is for operating person. Any requirement, please feel freely to contact our service engineer.

Power Source

This product is intended to operate from a power source between 85~265 volts rms . This product is only workable under correct power condition, which is already mark on the back panel of the power.

High Voltage

There are many high voltage components inside.

Do not Remove Covers and Panels

Do not remove Covers in any conditions. There are not any spare components inside for maintenance, so do not maintain this product by userrselves, any requirement, please feel free to contact our service engineer. Keep heavy device from power cord.

Grounding the Product and Use the Proper Fuse

This product is grounded through the grounding conductor of the power cord. To Avoid electrical shock, plug the power cord into a properly wired receptacle before connecting to the product input or output terminals.

Keep away from Magnet, Motor, TV and Transformer.

Guard Against Damp

Keep using inside clean and dryness environment, once the device get wet, must remove power cord right now.

Keep away Exploder

Do not operate the device inside dangerous and easy explosive gas, which it may make fire, blast or something without expectation.

Keep away Pour Liquid and Fragment

It is forbid to pour liquid, metal fragment or anything else inside this device to avoid fire and other accident. Once that happens, must remove power cord and try to make it clean before power on again.

VSP 516 Series User Manual Doc. No:RGB-RD-UM-V516E001 1

2.0 Specification

AVDSP series video processors are designed by the latest high performance image processing technology. AVDSP can handle following video without limit, include CVBS(Composite)、S-Video (YC)、YCbCr、YPbPr、RGBHV(VGA)、

DVI-D、HDMI、SDI(SD-SDI、HD-SDI) and VOIP(Copper RJ45).

Compare table of AVDSP as following.

VSP 516 Series User Manual Doc. No:RGB-RD-UM-V516E001 2

2.1 Parameters

Composite BNC Input

Number of Inputs 3

Supported Standards PAL/NTSC; 480i,576i

Signal Level 1Vpp±3db (0.7V Video+0.3v Sync ) 75ohm

S-video DIN4 Input

Number of Inputs 1

Supported Standards

Signal Level

PAL/NTSC; 480i,576i

Y:1Vpp±3dB (0.7V Video+0.3v Sync ) 75ohm

U/V:0.7Vpp±3dB 75ohm

YPbPr BNC Input

Number of Inputs

Supported Standards

Signal Level

BNC*3

Anologue HD Input

480i,576i,480p,576p,720p50,720i60,1080i50,1080p50

1080i50,1080i60

Y:1Vpp±3dB (0.7V Video+0.3v Sync ) 75ohm

Pb/Pr:0.7Vpp±3dB 75ohm

VGA DB15 Input

Number of Inputs

Connector

Supported Standards

Signal Level

1

Standard DB15 socket

VGA-UXGA;

1024×768×60, 800×600×60, 640×480×60

R、G、B、Hsync、Vsync:0 to1Vpp±3dB (0.7V Video+0.3v

Sync ) 75ohm black level:300mV Sync-tip:0V

DVI Input

Number of Inputs 1

Supported Resolution

Signal Level

SMPTE:625/25 PAL, 525/29.97 NTSC, 625/50p PAL,

525/59.94p

NTSC:1080i50,1080i59.94/60,720p50,720p59.94/60

VESA:800×600×60Hz,1024×768×60Hz,1280×768

× 60Hz,1280×1024×60Hz,1600×1200×60Hz,1920

× 1080×60Hz,1920×1080×50Hz

TMDS pwl,single pixel input,165MHz bandwidth

SDI Input (Optional module

Number of Inputs 1

Connector BNC

Data Rate Range 19.4Mbps~1.5Gbps

Supported Standards ITU-R BT.656,ITU-R BT.601,SMPTE 259M, SMPTE 292,

VSP 516 Series User Manual Doc. No:RGB-RD-UM-V516E001 3

Equalization)

Audio Input

Number of Inputs

Connector

Audio Standard

DVI Output

Number of Inputs

SMPTE 297

Belden 1694A 100M HD1.485G,350m SD 270Mbps

10

Standard RCA socket

48Kbps 24bit balance analog audio

1

Signal Level

Supported Standards

TMDS pwl, 165MHz bandwidth

VESA:800×600×60Hz,800×600×75Hz,1024×768

× 60Hz,1024×768×75Hz,1280×1024×60Hz, 1920

× 1080P×60Hz

VGA Output

Number of Inputs

Connector

Supported Standards

Signal Level

1

Standard DB15 socket

VESA:800×600×60Hz,800×600×75Hz,1024×768

× 60Hz,1024×768×75Hz,1280×1024×60Hz, 1920

× 1080P×60Hz

R、G、B、Hsync、Vsync:0 to1Vpp±3dB (0.7V Video+0.3v

Sync ) 75ohm black level:300mV Sync-tip:0V

Audio Output

Number of Outputs

Connector

Audio Standard

Function

Source Switch

PIP

AV Sync

Extras

1

Standard 1/4” socket

48Kbps 24bit balance analog audio support every signal alpha key operation

PIP for SD with HD and HD with HD supported

Power Supply

Working Environment

Stored Environment

Product Warranty

85-264V 2A IEC-3

0°C~45°C

10% to 90%

1 year

Note:

VSP 516H is different from VSP 516 as following output resolution.

800×600×75Hz,1024×768×75Hz,1280×768×60Hz

1920×1080p×60Hz

Specifications are subject to change without notice.

VSP 516 Series User Manual Doc. No:RGB-RD-UM-V516E001 4

3.0 Connection

3.1 VSP 516 Back Panel

1、Dial the code switch;

2 、 10/100M interface (copper RJ45). Used to connect the computer by

568B-568A twist-pair;

3、USB interface,Used to connect the computer;

4、RS232 interface (RJ11) for AVDSP processor. Used to connect the computer;

5-14、Audio interface, support audio signals from DVD player or audio sources;

15-16、Gigabit copper port, connect to LED screen;

17、Gigabit Transmitter card power interface, not use inside case;

18、Gigabit Transmitter card USB control interface.

19、Gigabit Transmitter card DVI input,connect to DVI output of VSP 516.

( This Connection does not support hot-plugging)

20、SDI Input BNC, used to support SD/HD SDI input。Input the video signal from the HD player, HD projector. (SDI input is the optional module)

Note:

VSP 516S can install a SDI input module to support SD-SDI and

HD-SDI signal, compared to VSP 516 and VSP 516H.

VSP 516 Series User Manual Doc. No:RGB-RD-UM-V516E001 5

21-23、Composite input interface,Composite BNC. Used to input composite signal (PAL, NTSC, SECAM compatible);

24 、 S-Video DIN 4, used to input S-Video signal ( PAL, NTSC, SECAM compatible);

25、DVI input interface。Input the video signal from computer, DVI signal generator. Connect to the same DVI interface on VSP 516;

( This Connection does not support hot-plugging)

26-28、R/Pr G/Y B/Pb BNC, used to support SD/HD analog video input, up to

1080p60;

29、VGA input interface, DB-15, used to support Analog RGB input; Connect to the VGA interface on the VSP processor.

30、AUDIO output interface2,connect to the audio player。

31、DVI output interface,connect to the monitor or LED screen which has DVI interface. (This Connection does not support hot-plugging)

32、VGA output interface, connect to the monitor, projector and so on;

33-34、Switch and power. It must use IEC-3 power line. Always ground to avoid electric shock.

VSP 516 Series User Manual Doc. No:RGB-RD-UM-V516E001 6

3.2 How to install

VSP 516 frame size

Note:

VSP 516S has the same frame size of VSP 516H and VSP 516S;

VSP 516 Series User Manual Doc. No:RGB-RD-UM-V516E001 7

4.0 Front Panel Keyboard Operation

Insert power cord and push power to ON position. LCD module on the front panel will show RGBLINK and go into self verification before it load last setting config and send processed image to the target monitor. For the first setup, CV1 input is default source. With front panel keyboard, user can operate VSP with menu display on LCD module.

4.1 VSP 516 series Operator Guideline

VSP 516 series front panel as following:

1. LCD Module;

2. Keyboard:

ESC: push to exit from current choice item;

SEL: push to confirm the current choice item;

UP: push to select up items in LCD menu;

DOWN: push to select down in LCD menu;

LEFT:push to select the left items

RIGHT:push to select the right items

CV1:switch to composite 1 input

CV2:switch to composite 2 input;

CV3:switch to composite 3 input;

SVID:switch to SVideo;

VGA: switch to analog RGB input;

YPbPr: switch to high definition component,

DVI: Switch to DVI input

+:Switch to amplify the audio;

-:Switch to down scale the audio;

VSP 516 Series User Manual Doc. No:RGB-RD-UM-V516E001 8

SDI: SDI input, compatible with HD/SD SDI, push to switch to SDI input;

Note:

VSP 516S can install a SDI input module to support SD-SDI and

HD-SDI signal, compared to VSP 516 and VSP 516H.

PBP:Switch to show two pictures in side by side mode;

Note:

VSP516S front panel remove PBP mode button to SDI button;

VSP516 and VSP516H front panel keep PBP mode button, but remove SDI button.

PIP:Switch to show picture in picture on the screen. CV1 is the default small picture on the top left corner, DVI is the default picture with full screen.

SAVE1:switch to use the user-defined mode 1;

SAVE2:switch to use the user-defined mode 2;

SAVE3:switch to use the user-defined mode 3;

FS:switch to selet full screen or zoom view, just for single picture mode;

RATIO:switch to select aspect ratio 4:3 or 16:9;

MSA:switch to select the audio channel which send to output in multi picture mode;

MUTE:Switch to select mute sound or return;

MENU:push to go to main menu;

FRE:push to freeze the video image or live again;(FreezeÆLiveÆFreeze)

AB: Channel Switch, only works under the PBP mode. Push it to switch between the picture of main channel and the picture of subchannel. For instance, if processor now works under subchannel mode, user can switch channels in subchannel; be under subchannel mode if you push Reset button.

AB in VSP 516 doesn't support Fade-In-Out.

Note:

VSP 516 Series User Manual Doc. No:RGB-RD-UM-V516E001 9

SCALE: push to go to between scaleÆzoomÆcropÆscale mode;

BRT:push to adjust the brightness and the contrast ratio, push to enter to the relevant Menu, and then push the UP and DOWN to adjust the brightness and the contrast ratio.

OUT: push to select the output format by using the UP and DOWN.

I/II: push to set single or dual channel

SAVE: push to save current config.

VSP 516 Series User Manual Doc. No:RGB-RD-UM-V516E001 10

4.2 Video Processor Menu

System menu as follows;

>VSP 516

*Dev Info Recall ↓

Fig. 1

The first line shows VSP 516.

Push the right and left direction key to select the left or right menu. Before the menu item, if there is a * sign, means the menu item has been selected, you can push the Select key to enter it.

The ↑ on the right means you can select the menu items by pushing the up and down direction key.

User can check the information of the equipment in “Dev Info” menu

(including the manufacturer、serial-number );

User can get more service and support according to the serial-number.

RGBlink Co ltd.

>SN:3204

User can check current input and output sources in Dev Info menu also.

Input: CV1 1024x768x60

Output: CV2 1024x768x60

Touch UP/DOWN to check customer service E-mail and web site address;

User can visit company web site for more product information. [email protected] www.rgblink.com

Touch UP/DOWN to check System time

System time:

2009-08-17 15:12:35

User can do a Factory Settings in Recall menu, after successful reset you will see the menu as follows:

VSP 516 Series User Manual Doc. No:RGB-RD-UM-V516E001 11

Factory reset was completed !

Push the MENU to enter the main menu, then push up and down direction key, the menu as follows:

>VSP 516

*Language Alpha ↑

Push the LEFT/RIGHT to select the relevant submenu.

LANGUAGE submenu as follows:

*LANGUAGE

>Chinese English

Push UP/DWON to enter Alpha setup, user can set value from 0 to 100,

0 means video or graphic would be disappear and 100 means normal;

Port A and Port B stand for two channel picture;

*Alpha

Port A Value: 100

Push OUT to enter the Output menu, push the UP or DOWN to select different output resolution, push OK to confirm the output resolution.

Advance submenu as follows:

① VSP516H and VSP 516S support the minus pixel shift

Note: function, which VSP 516 can not support;

② VSP516H and VSP 516S can not support pixel shift on the resolution 1920×1080P×60Hz.

Pixel shift to minus:

Press UP/DOWN and select the menu as shown in Figure 1:

>VSP 516

*Advance XY_Pos ↑

Figure 1

Press LEFT/RIGHT and select XY_Pos to enter the submenu of adjusting effective area;

VSP 516 Series User Manual Doc. No:RGB-RD-UM-V516E001 12

H_BLANK

*HS: 46

V_BLANK

*VS: 38

XY_Pos:The sub-menu of which is used to adjust the position of overall effective area shown on the screen or monitor.

H_BLANK: The overall effective area can be moved around by adjusting the value of H_BLANK.

V_BLANK: The overall effective area can be moved up and down by adjusting the value of V_BLANK.

Screen parameter:

Hsize: 1024

Step:user can set the step of scale;

HSize:set the horizontal size of the image;

VSize:set the vertical size of the image;

HPos:set the horizontal position of the image;

VPos:set the vertical position of the image;

User can set size and position of the screen simply, Mainly applies to LED screens users. After setting screen parameter, the user choice PIP or PBP operation, display picture can directly shows on corresponding screen。

Output

>1024x768x60

Push the / to enter Single or Dual channel menu , push the UP / DOWN to select the single or dual channel, push SEL to confirm the single channel or dual channel work state;

Setup

Dual

Setup

Single

Select the input channel, push the UP/DOWN, and SEL to confirm the

VSP 516 Series User Manual Doc. No:RGB-RD-UM-V516E001 13

different input channel. User can also push the channel name on the keyboard to go into the input channel.

Source Select

>CV1

AB in VSP 516 is used to enable channel if dual channel mode.

Setup

A on B

OR:

Setup

A on B

Push SCALE to set the size and position of the image, push UP/DOWN and

SEL to confirm the relevant items;

Step:user can set the step of scale;

HSize:set the horizontal size of the image;

VSize:set the vertical size of the image;

HPos:set the horizontal position of the image;

VPos:set the vertical position of the image;

Note:

Scale

> Step 10

When shown in one single image, the ratio between the horizontal and the vertical of the image should be equal to or less than 3.

When shown in dual image, there is a limit of aspect ratio of the image in the left side: The horizontal of the image in the left side should be larger than that of the image in the right side.

This rule still need to be followed even if the images are dragged to the opposite.

Push the FRE to freeze the live image or live the freeze image.

Freeze Frame

Once gain for live

OR:

VSP 516 Series User Manual Doc. No:RGB-RD-UM-V516E001 14

Live Frame

Once gain for live

Push BRT to set the brightness and the contrast ratio:

VSP 516

Brightness 50 ↓

OR:

VSP 516

Contrast 50 ↑

Push SAVE and then push SAVE1 or SAVE2 to save the operation to SAVE1 or

SAVE2;Push SAVE1 or SAVE2 to execute relative operation after user save the operation sucessfully.

Note:

Add prompt to save function

For VSP 516 series, when user push the SAVE key, the SAVE1、

SAVE2 and SAVE3 lights on the front panel will go on at the same time, it reminds user must press SAVE1 or SAVE 2 to finish the final save function.

Slelect Save Mode !

Push Esc To Exit

Touch FS button can realize screen switch between scale mode and full screen mode.

Picture mode

Full Size

Picture mode

Small Size

Touch RATIO button,set screen width and height.

Size: 4:3

Size: 16:9

VSP 516 Series User Manual Doc. No:RGB-RD-UM-V516E001 15

Size: Normal

MSA : touch the main sub-channel audio and audio channel switching button,main channel will play sound.

Main window audio

Touch again, sub-channel will play sound.

Sub window audio

MUTE:mute the equipment, shown as the picture:

Mute

Touch MUTE again will revovery to play sound.

VSP 516 Series User Manual Doc. No:RGB-RD-UM-V516E001 16

5.0 Communication Software Guideline

AVDSP video processor is very easy to be configured with user friendly communication software, support drag and drop operation for edit and display.

Also can customized with schedule function.

5.1 Install Software

Dual click AVDSP.exe to install, select Chinese or English version for use, after click “select ”to next dialog.

If user agree to install this software, please click next to go on, else click esc to exit this install.

And in next dialog is the user agreement of the software, click agree to go on and refuse to exit.

VSP 516 Series User Manual Doc. No:RGB-RD-UM-V516E001 17

If users agree to the agreement, user can select install directory in next dialog, else, click next to install software to default directory “C:\Program Files”.

Click “next ”to go on.

VSP 516 Series User Manual Doc. No:RGB-RD-UM-V516E001 18

Click “next ”to go on.

Click “finish” and ready to run AVDSP console.

VSP 516 Series User Manual Doc. No:RGB-RD-UM-V516E001 19

VSP 516 Series User Manual Doc. No:RGB-RD-UM-V516E001 20

5.2 Run AVDSP Console

Run AVDSP.exe and the console will auto detect device in serial or networks by detected Comm port and pro-define IP address.

After detect, open the device console, for example, if the device is VSP 618, then VSP 618 console will be load, as following. Default loading is VSP 516 if can not detect any device.

VSP 516 Series User Manual Doc. No:RGB-RD-UM-V516E001 21

Setup Communication

AVDSP Console support COM port or Ethernet (UDP) to access AVDSP.For the first running ,user must click the the COM Port and the Baudrate. to close COM Port. Click to change

Serial: user can make choice between existent com ports and baud rates; default Baudrate is 9600.

Ethernet: user can fill any number less than 1023 in Local Port. The Remote Port must be 192.168.0.100 and the Remote Port must be 1000.

VSP516 and VSP516H work Baud Rate as 9600, while VSP516S

Baud Rate works as 115200.

Note:

The COM Port is decided by user’s COM. Right click my computer icon on desktop, select HardwareÆDevice Manager in the system attributes dialog. The

COM in red in the picture is the COM user can make choice.

VSP 516 Series User Manual Doc. No:RGB-RD-UM-V516E001 22

Then click to open COM. connect the COM.

will display after success to

If AVDSP console success to detect device in chain, the software version, device core version, firmware version and serial number will display on the bottom right corner of the screen.

5 How to use

Operator can check parameters by software.

: Save script. Save current user config parameters as script.

: Open script. User can open saved script.

VSP 516 Series User Manual Doc. No:RGB-RD-UM-V516E001 23

: Import template. There are six templates for user.

: Export template. Export current config as template.

: Option. User can choose open device when start and using script saved before or execute schedule edited before when start.

If user choose open device when start, user can use last run, use script file or none when user start. User can click to choose which script user want to open.

If user choose execute schedule when start, the next dialogue will display when software run.

VSP 516 Series User Manual Doc. No:RGB-RD-UM-V516E001 24

: Language. The software supports Chinese and English version. The picture following is the Chinese dialogue.

: Exit.

Communication

: Open COM.

: Close COM.

: Set COM.

Device

: Synchronization.

: Save to flash.

: Load form Flash.

Load user config from flash.

: Factory setup

: Advance, for adm. inistrator control.

: Execute schedule or stop schedule.

VSP 516 Series User Manual Doc. No:RGB-RD-UM-V516E001 25

Help

: Help. Display helps dialogue.

: About.

Output resolution: user can choose different output resolution by selecting from pull down list.

Operating mode: choose to work in single channel or dual channel.

Layout: if in dual channel mode, user can set the device to work in PIP or PBP mode directly with quick preset layout button as following.

Input: the white area display the name of input interface when the mouse is over the interface picture on the left. The orange pane means current selected interface.

If work in dual channel, channel 1 includes VOIP, CV1, CV2, CV3, SVideo, YCbCr,

SDI 1 and SDI 2, and channel 2 includes DVI, YPbPr, VGA, HDMI1 and HDMI 2.

The cross over interface picture means they can not access. The orange pane

VSP 516 Series User Manual Doc. No:RGB-RD-UM-V516E001 26

means selected interface for channel 1. The blue pane means selected interface for channel 2.

Screen parameter:

User can set size and position of the screen simply, Mainly applies to LED screens users. After setting screen parameter, the user choice PIP or PBP operation, display picture can directly shows on corresponding screen。

Images: User can scale the images;image 2 can’t choose in single channel mode.

Display Toolbar

Display toolbar Users can set Alpha value of “dynamic Video” and “static current frame” through display toolbar.

Setting Gamma is generally not recommended, since LED large screen itself has

Gamma function.

For further information, users can contact with our customer service team.

VSP 516 Series User Manual Doc. No:RGB-RD-UM-V516E001 27

Output: user can customize the brightness and the contrast.

Display: user can customize image or images position and size just by drag and drop image (images) in this area. This process is sync to the parameters in images toolbars.

Log: user can save or delete the operate log file.

Added functions z Output polarity

Normally, the polarity will set to be positive.

If the Horizontal and vertical polarity of VSP 516 equipment is different from Tx, the polarity should be negative, or else it can not send data to the LED screen correctly.

VSP 516 Series User Manual Doc. No:RGB-RD-UM-V516E001 28

z IP set

Users can set equipment IP, Usually used under the condition of one computer control or remote control several computers. z Sound

If worked under the dual-screen mode, users can select main screen sound or sub-picture sound by clicking option box.

HDMI can transmit audio and video signals at the same time on one data line.

If users choose HDMI signal source with sound, users should choose“embedded audio”;

If users choose HDMI signal source without sound, users can broadcast sound through External speaker and choose” HDMI outside embedded audio”.

VSP 516 Series User Manual Doc. No:RGB-RD-UM-V516E001 29

z Clock

Users can set or adjust lower computer time through” clock” z Equipment Schedule function

Users can set device to work with schedule, and then device can automatically switch between single or dual channel, resize image, switch video and with fade effect in need.

Equipment currently supports max 10 regular content; users can set in the

“timing” option.

Specifically how to implement devising schedule function, please refer to

Appendix II.

VSP 516 Series User Manual Doc. No:RGB-RD-UM-V516E001 30

6.0 FAQ

6.1 No output in target display

1) Check the output config of the input video.

2) Check the input channel config is ok. Ex.The composite 1 interface is connected to the composite interface of video source.

3) Check the connection of output is ok.

4) Check the target monitor or display is not destroied or power down.

5)Check the output resolution of AVDSP is not out of the maximal resolution of target display.

6) Check ALPHA value is not 0.

7)Any requirement, please feel free to contact our customer service engineer.

6.2 VGA input could not work with AVDSP Console

1)Check VGA source output is ok.

2)Check VGA input resolution is not out of AVDSP Console support list, as following. The biggest input resolution is 1024*768*60Hz

3) Check AVDSP Console works in VGA input mode.

4) Any requirement, please feel free to contact our customer service engineer.

6.3 DVI input could not work with AVDSP

1) Check DVI source is ok.

2) Check DVI source output is not out of AVDSP support list.

3) Check AVDSP works in DVI input mode.

4) Check the connection between AVDSP and DVI source is correct. Restart DVI source and check output.

5) Any requirement, please feel free to contact our customer service engineer.

VSP 516 Series User Manual Doc. No:RGB-RD-UM-V516E001 31

6.4 Component input could not work with AVDSP

1) Check the connection between AVDSP and Component source is correct.

Especially Y signal. Refer to cabling example in page 5. High Definition component YPbPr is only support in YPbPr input。Standard definition YCbCr support 480i and 576i only; High Definition YPbPr support 480i、576i、480P、

576P、720P50、720P60、1080i50 and 1080i60;

2) Check component source works, normally DVD component output should be open from its menu.

3) No recommend to output component and SVideo input from the same source.

4) Any requirement, please feel free to contact our customer service engineer.

6.5 User settings can not save

VSP 516 supports multi config mode.For multi config mode, the equipment starts to work automatically with the SAVE1 mode.According to different equipments,you can solve the problems that modes can’t be saved by the following steps.

VSP 516

Confirm to press the “SAVE” button,then press “SAVE1”,or “SAVE2”,or

“SAVE3”,that will save the current operation mode to the “user mode 1”,”user mode 2” or ”user mode 3”; After that, push button “SAVE1”,””SAVE2,”SAVE3”,it wil call out the corresponding set -ting of user-mode.if that,the saving is successful.

Ater saving process, user should not do factory reset or any saving operation to user mode 1, otherwise, “SAVE1” will be over write.

6.6 Can’t update main board software

Connect the computer and AVDSP Series, select *.mot. Download file to device.

After the equipment power up, right-click the “.mot” file at the left side of menu, when the screen shows “waiting for update”, you can update the main board program. Next, choose the “download file to device”, start to loading.

VSP 516 Series User Manual Doc. No:RGB-RD-UM-V516E001 32

7.0 Quick Start

7.1 Single-screen control

Set screen parameters

Users can easily change the screen size and location by setting the parameters with keyboard and LCD menu.

Press MENU to access main menu, Menu shows as below picture:

>VSP 516

*Dev Info Recall ↓

Press UP / DOWN button to turn the menu shown as below pictures:

>VSP 516

*Advance ↑

Screen parameter:

Hsize: 1024

Step: Set the unit of zoom and move every time;

HSize:Set Horizontal size;

VSize:Set vertical size;

Hpos:Set horizontal coordinates(horizontal phase);

VPos:Set vertical size(vertical phase);

Scale pictures

Step:Set the unit of scale and move every time;

(Three steps available:1, 10,100)

HSize:Set horizontal size;

VSize:Set vertical size;

HPos:Set horizontal coordinates(horizontal phase);

VPos:Set vertical size(vertical phase);

Scale

> Step 10

VSP 516 Series User Manual Doc. No:RGB-RD-UM-V516E001 33

Set alpha

Enter Alpha sub-menu can set the alpha of video, Press UP /DOWN to set the value of alpha; Port A and Port B represent two video channels;

*Alpha

Port A Value: 100

Set brightness contrast

BRT brightness and contrast button can set brightness and contrast of active window video shown as below pictures:

VSP 516

Brightness 50 ↓

VSP 516

Contrast 50 ↑

BRT brightness and contrast button can set brightness and contrast of active window video shown as below pictures:

VSP 516

Brightness 50 ↓

VSP 516

Contrast 50 ↑

Freeze Frame

Press FRE static frame button can freeze, press the button can freeze current active window image; You can make the screen switch between static and active with this button; Pictures show as below:

Freeze Frame

Once gain for live or

Live Frame

Once gain for live

VSP 516 Series User Manual Doc. No:RGB-RD-UM-V516E001 34

7.2 How to control processor with console software by USB?

1. Install the driver;

Connect the USB cable to the PC and the video processor. Turn on the VSP516S, for the first time to use USB, the PC will remind finding the new hardware and ask to install the driver for this new driver.

Install from the list or specified location, press “NEXT”:

Press “ browser” to find the driver, and press “NEXT”

VSP 516 Series User Manual Doc. No:RGB-RD-UM-V516E001 35

When the installation fininsh, can go to check the installed COM port inside the device mangement, as following picture show:

VSP 516 Series User Manual Doc. No:RGB-RD-UM-V516E001 36

2. Install the console software, and run after install, shows the interface of the console as following:

VSP 516 Series User Manual Doc. No:RGB-RD-UM-V516E001 37

: Set the RS232 as installed just now, and set the VSP516S Boud Rate to be: 115200.

Press to start RS 232 communication, when there is green point in the right down corner showing on the software, it means the communication is OK, and you can use the software to control the device now; the software operation is the same as VSP516, just can see the difference of the SDI input;

If power off during communication, should close the port

Note: by first, and plug in out of the USB and do communication

again.

VSP 516 Series User Manual Doc. No:RGB-RD-UM-V516E001 38

7.3 How to Use LINSN Ledset software?

1. First, Install AVDSP software and LINSN software.

2. Run AVDSP software;

① Press to set the RS232. first choose the current RS232 you are using, then set the baud rate.

Note:

VSP516 and VSP516H Baud Rate work as 9600, while VSP516S

Baud Rate work as 115200.

Press to start the RJ232, when the green point showing on the right down corner, it means the communication is successful.

Press :option. Find the LINSN software installation file LEDSET.EXE through “external progress route”as following picture:

VSP 516 Series User Manual Doc. No:RGB-RD-UM-V516E001 39

As LINSN software will use RS232 for communication too, so user should first close AVDSP console software RS232 communication after that press

If in used

;

, then to start the LINSN software. When you want to use AVDSP software, you just need to close LINSN software, start the RS232 again.

Before using AVDSP console software to execute the LINSN

Note:: software, you should first internally connect the device's 100M board with sending card.

Any question, please feel free to contact our customer service engineer.

VSP 516 Series User Manual Doc. No:RGB-RD-UM-V516E001 40

8.0 Appendix

8.1 AppendixⅠ Download the IP software

Turn off the power, take the two coding switch to “ON” sate. As below:

Connect one side of the RJ11 download line to the RS232 on the video processor, and the other side to be connected to the serial port on the PC.

Double click to run Flash Magic ,setting as below:

First, users can choose the right serial port, set the baud rate to 9600, choose

LPC2368,and to load the aim document (hex.document) of IP board upgrading.

Secondly, confirm the two option box by tick.

VSP 516 Series User Manual Doc. No:RGB-RD-UM-V516E001 41

Finally, click the “Start” button.

After download, exit the program, turn off the power, tack the two coding switch back, as below, restart the equipment power, check if the equipment work normally.

Flash Magic download website:

Note: http://rgblink.com/_d269872174.htm

VSP 516 Series User Manual Doc. No:RGB-RD-UM-V516E001 42

8.2 Appendix Ⅱ How to add tasks.

Use “Device Schedule” can add tasks,make device automatically run to the

Schedule input source in specified time or schedule display modes such as fade in and out. z First of all,set lower computer current time through host computer “clock”.

Note

Reset to factory settings after setting the clock will affect the time before.

After Clock setting, users can check whether successfully set through button.

Press MENU button to enter system main menu, then press Dev Info (device information), then press SEL button can show device information. Touch

/DOWN,check in the System time. Shown as below picture:

System time:

2009-08-17 15:12:35 z After device clock set, add task plan through” Timing Parameters”.

1. Users need to start “time-enabled” before using” timing device”. If you forget to start, time set may fail.

VSP 516 Series User Manual Doc. No:RGB-RD-UM-V516E001 43

Click “start” button , when the button changes to , it means time can start.

Press MENU button can enter system main menu, touch UP/DOWN to enter advanced menu, shown as the picture:

>VSP 516

*Advance ↑

Press SEL button to enter advanced menu

Time:

Time Able

2. When the timer count is set to 1, it indicates that the setting contents will be stored in the “timing 1”. If you need to set more, you can set up one by one and saved in different “Timer index”.

Note: Equipment currently supports 10 task scheduler.

3. Set “task schedule” playing time,can up to second.

4. Select the signal source to play works in dual channel or single channel mode, and check whether to use fade during dual channel mode.

5. Users can control the image position and size by change the data or click the drop-down arrow.

6. When device works under the single channel mode, click the interface Icon.

Red box indicates current interface has been selected as the input interface;

When device works under the dual channel mode, need to switch image 1 and image 2 set input signal one by one.

Users can see the image 1 and image 2 input source information in the input

VSP 516 Series User Manual Doc. No:RGB-RD-UM-V516E001 44

source toolbar after setting. Shown as the picture:

7. When you finished above step, click button plan”.

to finish adding” tasks

Click button , you can see the input source, playing time, image size, position etc. of the current “tasks plan”

Users can see all the “tasks plan” relevant content through “Timer index” switching .

VSP 516 Series User Manual Doc. No:RGB-RD-UM-V516E001 45

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement