AERTECNICA TUBO CLASSIC TC Operation And Maintenance Manual
AERTECNICA TUBO CLASSIC TC is a versatile and high-performance central power unit designed for residential use. Its compact size and lightweight construction make it ideal for installation in tight spaces. The CLASSIC TC features a powerful motor that delivers exceptional suction power for thorough cleaning of carpets, hard floors, and upholstery. With its advanced filtration system, the CLASSIC TC effectively traps dust, allergens, and other airborne particles, ensuring a cleaner and healthier indoor environment.
Advertisement
Advertisement
Central power unit
PERFETTO INOX TXA
PERFETTO TPA
PERFETTO TP
CLASSIC TC
Index
GeneRAL InFORMATIOn
3 General warnings
3 Warranty
4 Safety
4 Certifications
4 Identification
4 Manufacturer
5 Identification plate
5 TUBÒ system description
6 Part description
7 Technical features
8 Foreseen use
8 Prohibited uses
8 Unauthorised uses
8 Operator
8 Starting/stopping
9 Built-in vacuum socket
9 Wireless kit
InSTALLATIOn
10 Opening the packaging
10 Handling the packaging
10 Installation location
11 Central power unit installation
allowances
12 Bracket fastening
13 Dust inlet line connection
13 Exhaust conveyor line connection
14 Connection of the exhaust line to the
ambient atmosphere
14 Air discharge grills
14 Electric motor air intakes
15 TUBÒ System electrical connection
16 Control panel with
AVI display and keyboard
17 Control panel operation with
AVI display
19 AVT control panel
19 AVT control panel functioning
20 Central power unit inspection
MAInTenAnCe
21 Maintenance of Perfetto TXA - TPA - TP
central power units
21 Container emptying
22 Clean Bag insertion
23 Filter cartridge replacement
24 Classic TC central
power unit maintenance
24 Container emptying
24 Filter cartridge replacement
26 Filter cartridge regeneration
27 Central power unit disposal
28 Anomaly and lock table (Perfetto TXA,
TPA and TP central power units)
30 Troubleshooting (Perfetto TXA, TPA
and TP central power units)
31 Anomaly and lock table
(Classic TC central power unit)
32 Troubleshooting (Classic TC central
power units)
General warninGs
Carefully read the manual
The installation, user and maintenance manual is an integral and essential part of the central power unit and must be read carefully as it contains important information concerning operator safety, foreseen operation and the correct maintenance of the central power unit.
Other additional warranty conditions will only and exclusively be the responsibility of the party proposing them.
For all disputes, the court of Forlì-Cesena (Italy) shall have exclusive jurisdiction and Italian legislation shall apply.
Keep the manual in a safe place
It is recommended to store the user manual in the multifunction pocket (in all PERFETTO TXA, TPA - TP models excluding models TX1A, TP1A , TP1 and the
CLASSIC TC series).
Warranty terms outside the European Union
For countries that are not part of the European Union, the warranty shall be the responsibility of the importing company and the warranty conditions shall be those foreseen by the applicable regulations in the country of import.
warranty
Warranty terms within the European Union
Aertecnica guarantees the proper operation of the purchased central power unit for a 24 month period starting from the documented purchase date.
If there is not any documentation that proves the purchase date (invoice or fiscal receipt), the 24 month period will refer to the date it was sold by AERTECNICA.
The warranty conditions are those provided by current
European legislation and in any case the following are not covered by the warranty:
NOTE
Aertecnica reserves the right to modify the product and the related technical documentation without incurring any obligation to third parties.
No part of this manual may be reproduced, copied or distributed in any manner without written authorisation from Aertecnica.
english
Faults, damage or breakage caused by incorrect electric connection during or after installation
Faults, damage or breakage caused by the malfunctioning of other components in the system, e.g., vacuum sockets, if these components are not from AERTECNICA.
Faults, damage or breakage caused by pipe clogging.
Damage or breakages owing to carelessness, negligence, inability or associated with prohibited or unauthorised uses.
Materials, components and accessories, including electric and electronic ones, when the damage is not related to original manufacturing defects or when the damage is due to component wear.
The manufacturer shall not accept any contractual and extra contractual liability due to damage caused by errors in using and installing the central power unit or due to failure to observe the instructions provided by the manufacturer.
The warranty will lapse in the case of tampering, repairs carried out by unauthorised individuals.
Aertecnica declines all liability concerning decreased performance or damage to the central power unit due to the use of non-original spare parts.
This manual is printed on 100% recycled paper
3
english
safety
The operator must accurately respect the following operating instructions in order to guarantee the safety of persons and the functioning of the central power unit.
HAZARD: this indicates that attention must be paid in order to prevent events that could cause serious accidents that harm people or their health.
HAZARDS OF AN ELECTRIC NATURE: make sure that the central power unit is connected with the relative cable to a standard compliant earthing system.
The power supply and relative socket must be suited to the nominal power of the central power unit. For exterior installations, the power socket must have a suitable IP rating.
SERIES: PERFETTO INOX TXA
MOD: TX1A - TX2A - TX3A - TX4A
SERIES: PERFETTO TPA
MOD: TP1A - TP2A - TP3A - TP4A
CRUSHING HAZARD: when handling and installing the central power unit it is recommended to use suitable equipment for lifting and securing it to prevent the central power unit from falling accidentally.
SERIES: PERFETTO TP
MOD: TP1 - TP2 - TP3 - TP4
SERIES: CLASSIC TC
MOD: TC1 - TC2 - TC3 - TC4
HAZARD OF DAMAGING THE CENTRAL POWER
UNIT: follow the provided instructions for use to prevent consequences that could damage the central power unit.
INHALATION OF HARMFUL ELEMENTS AND DUST: protect respiratory organs by using protective masks when emptying the dust containers and when replacing the filter cartridge so the collected dust is not inhaled.
DUST SENSITIVITY: this means that hand protection must be used to prevent harming operators who are sensitive to the collected dust.
Product certification for the singlephase power unit range for the residential market sector, series:
PERFETTO INOX TXA
PERFETTO TPA
PERFETTO TP
CLASSIC TC
iDentification
This user and maintenance manual is an inherent part of the central power unit:
Manufacturer
AERTECNICA S.p.A.
Via Cerchia di Sant’Egidio,760
47521 Cesena (FC) ITALY
Tel. +39 0547/637311
Fax +39 0547/631388 [email protected]
www.aertecnica.com
Technical service
The Technical Service Centre can be contacted for all technical problems and in order to request spare parts.
For all communications concerning the central power unit, the user should always provide the following data: central power unit model serial number year of manufacturing date of purchase and a detailed description of the discovered problems.
certifications
Aertecnica S.p.A is a company certified with:
Quality system
UNI EN ISO 9001
Environmental management system
UNI EN ISO 14001
When replacing the central power unit's spare parts it is recommended to use original spare parts; Aertecnica declines all liability concerning decreased performance or damage to the central power unit due to the use of non-original spare parts.
4 User and maintenance manual
iDentification plate
For these models, the identification plate is located on the body of the central power unit as shown in the figure.
The necessary identification data: model serial number year of manufacturing.
Description of the tubò vacuuM systeM
The purchased central power unit is the main component of TUbò, Aertecnica's advanced vacuum system.
The TUbò system consists of the central power unit, vacuum sockets installed in the building's walls, the hose that is inserted in the vacuum sockets based on the room to be cleaned and a set of cleaning accessories suitable for all residential needs.
A network of plastic pipes installed under the floor and in the walls of the building form the dust intake line that is connected to the central power unit.
The system can reach all areas of the home, both inside as well as outside depending on the position of the vacuum sockets installed in the building. The recommended hose is 7 m long, which makes it possible to cover a circular area of approx. 30 m2 (a reduction in the radius of the circumference is due to obstacles in the room (furniture) that make it necessary for the tube to follow a curved path).
The dust container must be emptied periodically (approx.
2-3 times a year; see paragraph CONTAINER EMPTYING).
english
The collected dust reaches the central power unit; the large dust particles fall into the collection container whereas a filter cartridge retains the suspended dust; the micro dust (invisible to the eye and not filtered by the cartridge) is discharged outside through the air exhaust line, guaranteeing home hygiene and preventing the dust from recirculating in homes.
The filter cartridge should be replaced with a new one every 2-3 years (based on its use; see paragraph FILTER
CARTRIDGE REPLACEMENT).
The filter cartridge can be regenerated by washing it periodically (based on its use; see paragraph FILTER
CARTRIDGE REGENERATION).
The system must only be used by one operator.
The system must only be used with the hose and cleaning accessories connected to Aertecnica sockets installed in the building.
These timescales are approximate for normal vacuum system use. In the case of intense use of the system and a large amount of vacuumed dust, the timescale will be shortened.
5
english
part Description
1
15
1
2
3 4 5
6
8
10
8
9
12
11
7
11
19
20
1
14
12
8
10
13
15
14
16
9
7
2
1
3 4 5
14
17
6
11
8
13
13
CLASSIC TC LINE
1 - Dual right/left air exhaust
2 - Motor air intake (mod. CLASSIC TC3, TC4)
3 - Sound-proofed motor chamber
4 - Electric motor
5 - Temperature sensor
6 - Power electronic board
7 - AVT panel
8 - Dual right/left dust inlet
9 - PRECISION filter cartridge
10 - QUICK FIX bracket
11 - Ergonomic handles
12 - Cone conveyor
13 - Dust container
14 - Dust inlet closing cap
15 - 12V socket line and power supply line casing
6
PERFETTO INOX TXA, TPA AND TP LINE
1 - Dual right/left air exhaust
2 - Motor air intake (excluding mod. PERFETTO TX1A, TP1A and TP1)
3 - Sound-proofed motor chamber
4 - Electric motor
5 - Temperature sensor
6 - Electronic card EVOLUTION 1.0
7 –AVI display and bult-in keyboard
8 - Dual right/left dust inlet
9 - built-in vacuum socket
10 - PRECISION filter cartridge
11 - Self-Cleaning filter APF system
(mod. PERFETTO TXA and TPA)
12 - QUICK FIX bracket
13 - Side multifunction pockets
(excluding mod. PERFETTO TX1A, TP1A and TP1)
14 - Ergonomic handles
15 - Cone conveyor
16 - CLEAN bAG dust bag
17 - CLEAN bAG blocking system
18 - Dust container
19 - Dust inlet closing cap
20 - 12V socket line and power supply line casing
User and maintenance manual
technical features
Line
Model
Power supply
Motor power
Frequency
Electric protection
Motor rpm
TX1A
Perfetto INOX TXA
TX2A TX3A TX4A TP1A
TP1
Perfetto TPA
TP
TP2A
TP2
TP3A
TP3
TP4A
TP4
TC1
Classic TC
TC2 TC3 TC4
Volt (Vac)
Watts (W)
H z
IP rpm
(giri/min.)
220/240 220/240 220/240 220/240 220/240 220/240 220/240 220/240 220/240 220/240 220/240 220/240
1.260
1.600
1.350
1.590
1.260
1.600
1.350
1.590
1.260
1.600
1.350
1.590
50/60
IP55 1
50/60
IP55 1
50/60
IP45 2
50/60
IP45 2
50/60
IP55 1
50/60
IP55 1
50/60
IP45 2
50/60
IP45 2
50/60
IP55 1
50/60
IP55 1
50/60
IP45 2
50/60
IP45 2
43.507
46.480
29.892
31.672
43.507
46.480
29.892
31.672
43.507
46.480
29.892
31.672
no.
1 1 3 3 1 1 3 3 1 1 3 3
Turbine stages
Socket power supply Volt (Vcc)
Vacuum power
Max. air flow rate
Air Watts m 3 /h
12
504
207
12
653
195
12
526
174
12
566
168
12
504
207
12
653
195
12
526
174
12
566
168
12
504
207
12
653
195
12
526
174
12
566
168
Max. vacuum mbar 270 313 374 413 270 313 374 413 270 313 374 413
63
8.200
64 64,5
12.300
12.300
62,5
4.000
63
8.200
64 64,5
12.300
12.300
Noise
Filter cartridge surface
Filter cartridge material
Dust container capacity
Height
Diameter
Weight
Dynamic
Control Display compatibility
(CMT800)
Wireless system compatibility
(CM187)
SOFT START starting
Right and left dust inlet
Right and left air exhaust
AVI display
AVT panel
ModBus communication system
QUICK FIX bracket
APF system
Built-in vacuum socket
CLEAN BAG
Multifunction
Pockets
Silencer as standard equipment dB cm 2 litres cm cm kg
62,5
4.000
13,5
60
30
10,8
YES
YES
YES
YES
YES
YES
NO
YES
YES
YES
YES
YES
NO
NO
63
8.200
13,5
90
30
13,8
YES
YES
YES
YES
YES
YES
NO
YES
YES
YES
NO
YES
YES
YES
YES
64
12.300
POLYESTER
YES
YES
YES
YES
YES
YES
NO
YES
YES
YES
YES
YES
YES
YES
22
115
34
17,3
64,5
12.300
YES
YES
YES
YES
22
115
34
17,3
YES
YES
YES
YES
YES
YES
NO
YES
YES
YES
62,5
4.000
13,5
60
30
10,8
9,8
YES
YES
YES
YES
YES
YES
NO
YES
1
IP55 exhaust conveyor with exhaust tubing
IP43 direct exhaust from the central power unit, without exhaust piping
YES
YES
NO
YES
YES
NO
NO
POLYESTER
13,5
90
30
13,8
12,8
YES
YES
YES
YES
YES
YES
NO
YES
YES
YES
NO
YES
YES
YES
YES
22
115
34
17,3
16,3
YES
YES
YES
YES
YES
YES
NO
YES
YES
YES
NO
YES
YES
YES
YES
22
115
34
17,3
16,3
YES
YES
YES
YES
YES
YES
NO
YES
YES
YES
NO
YES
YES
YES
YES
13,5
60
30
9,5
YES
YES
YES
YES
YES
NO
YES
YES
YES
NO
NO
NO
NO
NO
POLYESTER
YES
YES
YES
YES
YES
NO
YES
YES
YES
NO
NO
NO
NO
YES
13,5
90
30
12,2
NO
NO
NO
YES
22
115
34
15,3
YES
YES
YES
YES
YES
NO
YES
YES
YES
NO
2
IP45 exhaust conveyor with exhaust tubing
IP43 direct exhaust from the central power unit, without exhaust piping
22
115
34
15,3
YES
YES
YES
YES
YES
NO
YES
YES
YES
NO
NO
NO
NO
YES english
7
english
foreseen use
The central power unit was designed to be connected to tubing able to vacuum dust. The operator uses the hose and cleaning accessories connected to the
Aertecnica sockets. The system must only be used by a single operator to only vacuum dust or minuscule solid particles, using only one vacuum socket at a time in order to secure adequate efficiency.
The CLEAN bAG (in the PERFETTO TXA, TPA and TP series) must be replaced with a new one each time that it is filled.
The dust container (in the CLASSIC TC series) must be emptied each time that it is filled.
The filter cartridge must be regenerated periodically and must be replaced every 2-3 years or immediately if it breaks. When replacing spare parts, use original
Aertecnica spare parts.
Use personal protection garments before carrying out operations such as emptying the dust container or replacing/cleaning the filtering cartridge.
Liquid can be vacuumed using a special accessory (art.
AP372; art. AP373).
- Do not vacuum dust using more than one vacuum socket at the same time.
- Never leave the hose and cleaning accessories connected to the system unattended whilst the central power unit is on.
operator
The operator must not present limited physical, sensory or mental capabilities; the operator must not be an unskilled person or a person with no knowledge of the product unless the aforementioned is under the supervision of somebody responsible for their safety or has received instructions with regards using the central power unit.
The operator must be over the age of 14 years.
The operator must always be careful when using the system in order to avoid tripping over the hose or cleaning accessories connected to the system, and must extend these same personal safety measures to the persons which may be present in the area at the same time.
prohibiteD use
- Do not vacuum lighted cigarettes, hot embers or burning material: these materials may cause a fire to start that would damage the hoses and the central power unit.
- Do not vacuum cloths, rags, fabrics or textile material: these materials could obstruct the hoses or damage the central power unit .
- Do not allow children to play with the vacuum sockets, opening and closing them continuously or inserting toys or solid items of unsuitable dimensions.
- Do not use the system with the central power unit turned on without the filter cartridge inserted.
- Do not block the air exhaust line.
- Do not block the air sockets for electric motor cooling.
- Do not use the cleaning accessories to vacuum parts of the body.
- Do not install the central power unit in an environment classified as ATEX as per European Union standards.
turninG on/off
The standard hose comes in two types:
TYPE 1 : hose with an activator union: the central power unit turns on when the union (b) is inserted in the vacuum socket (A).
TYPE 2 : hose with a switch: the central power unit is turned on using the switch on the hose itself.
Insert the hose-socket union with the special plates (D) in correspondence of the contacts (E) inside the socket.
To turn off the central power unit: with the TYPE 1 hose, remove the hose from the vacuum socket (A); with the TYPE 2 hose, move the switch to the OFF position
E
E
unauthoriseD use
- Do not vacuum liquids, materials saturated with liquids or very moist materials: these materials could cause the electric system to short circuit, prevent the proper passage of the dust or damage the sockets and the central power unit.
A
TYPE 1
B
A
TYPE 2
C
D
8 User and maintenance manual
NOTE
With socket models Air Active, Open and the NEW AIR sockets with a microswitch (NA699) the central power unit turns on when the socket door is opened.
built-in vacuuM socket
The models in the PERFETTO TXA, TPA and TP line have a built-in vacuum socket (1).
Turning on the central power unit
After inserting the union (3) in the socket (1), start the central power unit by pressing the START button on the control panel (4).
Turning off the central power unit
The central power unit turns off by pressing the STOP button on the control panel (5) for one second or 15 seconds after closing the door (2).
The built-in vacuum socket can be used for cleaning the central power unit's equipment room.
1
4
the wireless kit (cM187)
The Wireless hose is the solution for situations in which the system does not have the electrical preparation or to add a new socket to an already existing system without installing the 12V socket line.
It can be used with all types of vacuum sockets.
The kit includes a wireless hose (1) and a receiver (2).
The 12V socket line cable that is supplied with the central power unit must be connected directly to the wireless input on the central power unit's electronic card
Receiver transmission power
Inside a building, the transmission range between the wireless hose and the receiver is 15 m, which makes it possible to go up or down 2 floors.
Starting/stopping the central power unit
The central power starts when the START/STOP button is pressed (3). The LED (4) turns green.
The central power unit stops when the START/STOP button is pressed again or 15 seconds after the vacuum socket door is closed.
3
4
5
OK mbar
9
1
3
2
1,5 mt.
2 english
english
opening the packaging
The central power unit is delivered inside cardboard packaging to make it easier to transport.
It is recommended to not remove the packaging until installation to prevent damaging it.
inStallation location
The central power unit must be installed in well-ventilated service rooms (for example, closets, garages, cellars or attic rooms) protected from significant climate changes.
The high level of electrical protection and resistance to the elements allows for the extension of installation of the central power unit to outdoor environments, on balconies, loggias and verandahs.
When opening the central power unit packaging, follow the instructions indicated on the sides of the cardboard box.
Check that the product is not damaged and that the box contains the warranty voucher with the coupon to be filled out completely and resent to Aertecnica (see
WArrAnTy paragraph).
The 220/240 power supply and the socket activation line must be near to the central power unit in order to activate the vacuum cleaning system.
The installation location must have adequate dimensions
(a minimum of 1,000 mm in front of the central power unit) to allow for filter cartridge, dust bag or dust container replacement operations.
The installation location must be sufficiently illuminated
(minimum of 300 lumen) to allow for maintenance operations and operations on the central power unit control panel.
The central power unit must not be placed in an environment classified as ATEX.
handling the packaging
To lift and transport the central power unit, use the handles positioned on the sides of the packaging (A).
NOTE
The packaging elements that accompany the central power unit upon delivery are inert solid waste that must be disposed of according to current applicable regulations.
NOTE
External central power unit
When installing the central power unit externally ensure that a junction box with an adequate degree of electrical protection is used.
10 User and maintenance manual
centRal poWeR Unit inStallation alloWanceS
The following table specifies the main reference allowances for correct central power unit installation.
I
D
C
B
240 V
12 V
E
N
Q
I
B
D
F
H
L
350
300
230
G 34
600
273
115
M 103
34
PERFETTO TXA
TX1A TX2A TX3A TX4A
A 138 328 418 418
350
C 257 257
300
E 286 286
230
900
273
115
103
350
257
340
304
340
34
1115
308
137
112
350
257
340
304
340
34
1115
308
137
112
N 560 560
P** 1500 1400
600
1400
600
1400
P**
Q recommended allowance floor level
The indicates measurements are in mm.
34
600
273
115
257
300
286
230
PERFETTO TP - PERFETTO TPA
TP1/TP1A TP2/TP2A TP3/TP3A TP4/TP4A
138 328 418 418
350 350 350 350
257
300
286
230
257 257
340 340
304 304
340 340
34
900
34 34
1115 1115
273 308 308
115 137 137
103
560
1500
103 112 112
560 600 600
1400 1400 1400
11
257
300
286
230
TC1
138
350
34
600
273
115
103
560
1500
34
900
273
115
257
300
286
230
CLASSIC TC
TC2
328
350
TC3
418
350
257
340
304
340
34
1115
308
137
103
560
1400
112
600
1400
257
340
304
340
TC4
418
350
34
1115
308
137
112
600
1400 english
bRacket faStening
1 - Make the holes in the wall
4 - With a simple left to right movement, slide the central power unit support to the end stop.
english
2 - Fasten the bracket to the wall following the described assembly order:
A - Screw 6x70
B - Flat washer 6x24
C - rubber washer
D - End stop
E - rubber antivibration pad
5 - The lock hook must release with a CLICK; use a screwdriver for leverage if necessary (see figure 6, letter F).
A
B
C
D
E
B
3 - Stand with the central power unit in front of the bracket and use a downward movement to hook the central power unit support to the bracket slide.
Unhooking the central power unit
F
6 - To unhook the central power unit from the support, press the lock hook with the help of a screw driver (F).
Slide the central power unit to the left and lift it.
12 User and maintenance manual
connection dUSt inlet line
Dust inlet line connection
All of the central power units have a dual dust inlet to permit the connection of the socket line hose on both sides of the central power unit, making installation easier.
Select the most convenient central power unit dust inlet to connect the dust inlet line. Assemble the rubber sleeve (a) on the dust inlet using the two provided clamps (b) and connect it to the inlet hose (c).
NOTE
Close the dust inlet not in use
The dust inlet not in use (d) must be closed by pressing on the relevant closing cap (e) provided.
c b a
OK mbar e d d d
OK mbar a b c english
connection exhaUSt conveyoR line
All of the central power units have a dual air exhaust outlet to permit the installation of the air exhaust line on both sides of the central power unit, making installation easier.
Select the most convenient air exhaust outlet to connect the central power unit. Connect the exhaust conveyor line hose with the provided clamp (f).
It is recommended to install an exhaust hose that is no longer than 5 metres.
If the exhaust line is longer, use a hose with a diameter of ø 63 or larger and install a silencer of a suitable diameter.
Always position the silencer near the exhaust grille.
Air exhaust line components
1 - silencer ø100
2 - conical increase ø50F - ø82F
3 - exhaust grille ø82
4 - outlet hole ø82
Use an exhaust grille code Tr310 or similar grille without the presence of insect protection netting.
In the instance of a ø50 terminal, use an exhaust grille code Tr316.
g
OK mbar f max 5m.
ø 50
1
300 mm
ø100
ø 50
4
ø 82
3
ø 82
2
13
NOTE
Close the air discharge union not in use
The air discharge union not in use (g) must be closed using cap (h) and fixed using the clamp (f) provided.
aiR diSchaRge gRille
Fit the 2 grilles in both air exhaust openings following the instructions indicated below.
The inner side is the one with the grille; the grille blades must be rotated downward.
h g
The external side is the one with a helicoidal section drawing.
f english
diRect exteRnal aiR exhaUSt line
If the central power unit is installed outside (on a terrace, balcony or loggia) the air exhaust conveyor is not needed as it uses the air exhaust openings (J) on the central power unit itself.
It is necessary to assemble, on both openings (J) the relevant discharge grilles, provided with the central power unit, according to the description provided in the following paragraph.
NOTE
This solution is indicated only for central power units installed externally.
electRic motoR aiR intakeS
The PErFETTO TX3A and TX4A, TP3A and TP4A, TP3 and TP4, TC3 and TC4 power units have air intakes (h) that must not be blocked to guarantee electric motor cooling.
h h
J J
OK mbar remove the internal protective sponge (k) and wash it once a year to ensure air passage.
k h
14 User and maintenance manual
electRical connection of the tUbÒ SyStem
DANGER OF ELECTROCUTION
Make sure that the electric line is dimensioned to support the central power unit power and check that the mains network corresponds to the voltage specified on the identification plate.
Connection of the central power unit to the power supply line
The power supply cable with Schuko plug (A) for the central power unit is supplied as standard equipment with the central power unit .
Connection of the central power unit to the socket line
A socket cable connection is supplied with the socket activation line and remote data transmission (B) as standard equipment.
ELECTRICAL CONNECTION DIAGRAM
To make the socket line connection, wire the central power unit connection cable as shown in the figure
2
OK mbar
The central power unit electric power supply system must be installed by qualified personnel in compliance with current applicable regulations.
The manufacturer declines all liability for poor operation or damage to people and/ or property due to connection to a noncompliant electric system
A
B english white yellow gray green brown
Vacuum socket contact
1
3
3 red blue green black
1 2 1 2 3 4 5 6
5
7
7
General components
1 - central power unit power supply cable
2 - 12v socket cable line
+ Dynamic Control Display (CMT800)
3 - electric junction box
4 - pre-wired sheathing 2x1 ø16 for socket line
5 - pre-wired sheathing 4x1 ø16
6 - inlet frames
7 - Dynamic Control Display (CMT800)
2 4
DISCONNECT THE POWER SUPPLY
TO THE CENTRAL POWER UNIT
To fully disconnect the central power unit from the electric line, remove the Schuko plug (A) from the power point.
6
ELECTRICAL DANGER
If the power supply cable is damaged, it must be replaced by the manufacturer or its
Technical Service Centre or in any case by a specialised technician in order to prevent all electrical hazards.
15
contRol panel
With avi diSplay and keyboaRd
(for PERFETTO TXA, TPA and TP central power units)
The central power unit has a control panel that includes an AVI display (immediate display) and a built-in keyboard to navigate and control the various central power unit operating parameters.
english
AVI DISPLAY
The alpha-numeric display is controlled by the
EVOLUTIOn 1.0 electronic card and is used to control the following parameters:
KEYBOARD
The keyboard has 4 buttons that are used to perform the following functions:
CLEAN BAG FILLING
This detects the filling level of the dust container and displays 4 different levels.
FILTER CARTRIDGE SATURATION
This detects the saturation level of the filter cartridge and displays 5 different levels.
OPERATING VACUUM RANGE
This displays the vacuum level at which the central power unit is operating: LO (low) - OK (correct) - HI
(high)
OPERATING VACUUM
This displays the operating vacuum level of the central power unit
MOTOR POWER PERCENTAGE
This displays the motor power percentage that is adjusted on the hose with the speed variator.
TOTAL MOTOR HOURS
This displays the total hours of use of the central power unit.
MOTOR TEMPERATURE
Displays the motor temperature.
STARTING ANOMALY/LOCK
Displays an anomaly/lock due to an excessive number of starts within a 1 minute period.
MOTOR TEMPERATURE ANOMALY/LOCK
Displays an anomaly/lock due to the engine temperature exceeding 80°C.
MAXIMUM USE TIME ANOMALY/LOCK
Displays an anomaly/lock due to continuous use of the central power unit for 30 minutes.
START BUTTON / r
The STArT button is used to start the central power unit after inserting the hose in the built-in vacuum socket.
The r arrow is used to navigate the upper menu in the programme.
STOP BUTTON / s
The STOP button is used to turn off the central power unit. The unit also turns off 15 seconds after the built-in vacuum socket door is closed. The s arrow is used to navigate the lower menu in the programme.
RESET/ESC BUTTON
Pressing the button, the central power unit is reset after a lock or anomaly (see AnOMALy Or LOCK paragraph).
MENU/OK BUTTON
By pressing the button, it displays the central power unit's maintenance cycles.
16 User and maintenance manual
CONTROL PANEL OPERATION
ALPHA - NUMERIC DISPLAY
With the central power unit ON, it displays the following operating parameters:
Once the vacuuming phase is completed with the central power unit in STAND BY, this displays the following operating parameters:
OK
TOTAL MOTOR HOURS this displays the total hours of use of the central power unit OK mbar
OPERATING VACUUM
In standard operating conditions, it displays the operating vacuum level of the central power unit
MOTOR POWER PERCENTAGE by pressing the MENU key once, it displays the motor power percentage that is adjusted on the hose with the speed variator.
FILTER SATURATION by pressing the MENU key once, it displays the saturation degree of the filter cartridge, expressed in mbar according to this reference scale:
0 mbar = filter clean
10 mbar = filter saturated 50%
20 mbar = filter saturated 100% english
OK
TOTAL MOTOR HOURS pressing the MENU key twice, it displays the total hours of central power unit use h
BAG FILLING pressing the MENU key twice, it displays the amount of time that passed, in hours, since the last CLEAN BAG maintenance was performed
MOTOR TEMPERATURE pressing the MENU key three times, it displays the temperature of the motor chamber
STAND BY
If 30 seconds pass without pressing any key,
3 continuously flashing LED appear in the display.
By pressing any key, the central power unit exits STAND BY status and displays the total hours of central power unit use.
17
CONTAINER/CLEAN BAG
FILLING LEVEL
This calculates the presumed filling level of the dust container or CLEAn BAG, using 4 progressive stages.
OPERATING VACUUM RANGE
Indicates the vacuuming power at which the system is operating. 3 different vacuum levels are shown on the display vacuum low
(0 - 89) mbar) vacuum correct
(90 - 170) mbar) vacuum high
(171 - 240 mbar) filling level 25-49 % filling level 50-74 %
If the system operates at a vacuum level greater than 240 mbar, the wording will flash and the central power unit will be locked after 15 seconds due to excessive operating vacuum.
(see AnOMALy AnD LOCK TABLE) english
+ filling level 75-99 % filling level 100 % - the bag is completely full and must be replaced
(see AnOMALy AnD LOCK TABLE)
FILTER CARTRIDGE
SATURATION LEVEL
The filter cartridge saturation level is displayed with 5 progressive stages.
STARTING ANOMALY/LOCK
Displays an anomaly/lock due to an excessive number of starts/stops within a 1 minute period.
+
After 5 consecutive starts during a one minute period, the warning light signals that the central power unit will be locked if started again within one minute. (see
AnOMALy AnD LOCK TABLE)
After 6 consecutive starts during a one minute period, the central power unit is locked.
(see AnOMALy AnD LOCK TABLE) saturation 20 - 39 % saturation 40 - 59 % saturation 60 - 79 %
MOTOR TEMPERATURE ANOMALY/LOCK
Displays an anomaly/lock due to the motor chamber temperature exceeding 80°C.
+ the temperature warning light appears, which flashes together with the fixed maintenance warning light that indicates a central power unit lock due to motor chamber overheating.
(see AnOMALy AnD LOCK TABLE)
+ saturation 80 - 99 % saturation 100 % - the central control unit stops due to filter saturation lock.
(see AnOMALy AnD LOCK TABLE)
MAXIMUM USE TIME ANOMALY/LOCK
Displays an anomaly/lock due to continuous use of the system for 30 minutes.
After 29 minutes of continuous system use, a flashing clock appears that indicates the maximum use time.
(see AnOMALy AnD LOCK TABLE)
The central power unit is locked due to continuous system use for 30 minutes.
(see AnOMALy AnD LOCK TABLE)
18 User and maintenance manual
AVT conTrol pAnel
(on CLASSIC TC central power units)
AVT PANEL
The central power unit is equipped with an AVT panel
(timed display) that makes it possible to display the central power unit's main maintenance operations.
CONTROL PANEL OPERATION
DUST CONTAINER FILLING LED
Indicates the presumed maximum filling of the dust container.
When the LED turns on, the dust container is full and must be emptied.
Perform the maintenance and turn off the signal by pressing the PRESS RESET button.
LED STAND BY
This indicates that the central power unit is powered but not being used.
FILTER CARTRIDGE SATURATION LED
Indicates the presumed maximum saturation of the filter cartridge.
When the warning light turns on, the filter cartridge is saturated and must be regenerated or replaced.
Perform the maintenance and turn off the signal by pressing the PRESS RESET button.
PRESS RESET BUTTON
This is used to reset central power unit anomalies
HIGH OPERATING VACUUM LOCK
The central power unit is locked because the operating vacuum exceeded the 240 mbar limit for more than 15 seconds;
The ON and PRESS RESET lights blink ( see LOCK TABLE of the TC central power units)
MOTOR TEMPERATURE LED
This indicates a central power unit lock due to a motor chamber temperature that exceeds 80°C.
To reset central power unit use, the temperature must go below 55°C.
After the temperature has gone below 55°C, press the
PRESS RESET button to remove the signal
Switch off the signal by pressing the PRESS RESET button.
english
LED ON
This indicates normal central power unit operation.
LED ON BLINKING
Indicates that the operating vacuum exceeds the value of 240 mbar. The central power unit will be locked after
15 seconds.
19
central power unit inspection
The general centralised vacuum system inspection must be done after the final assembly of all vacuum sockets and the selected central power unit
PERFETTO TXA, TPA AND TP CENTRAL POWER UNITS
Check 1
Activate the central power unit with all sockets closed by pressing the START button on the control panel. The display will show the maximum vacuum level reached by the central power unit, which will stop automatically after 15 seconds.
Note the value that was reached (value 1).
Disconnect the tubing from the central power unit and place a cap on the central power unit inlet.
Reactivate the central power unit and note the value that was reached (value 2) indicated on the display.
Check that the difference between values 2 and 1 does not exceed 15 mbar.
If the value is higher, this means that there are leaks that must be found and repaired.
Check 2
Compare value 2 with the vacuum value indicated in the technical features table for the central power unit model that was purchased.
Check that the difference between the two values does not exceed 10% of the table value.
If the value is higher, contact the Aertecnica Service Centre.
english
Note
The values indicated in the table refer to a power supply voltage of 240 V at 50 Hz. If the mains voltage is less, use the following formula: every 10 volt = 10 mbar (example with the TP1 central power unit: 270 mbar at 240 V = 250 mbar at 220 V).
CLASSIC TC CENTRAL POWER UNITS
Check 1
Activate the central power unit with all sockets closed, jumpering the 12V socket line.
Inserting the vacuum gauge in the dust inlet that is not used or in any vacuum socket, check the vacuum value obtained by the central power unit, which will stop automatically after 15 seconds. Note the value that was reached (value 1).
Disconnect the tubing from the central power unit and insert a vacuum gauge (AT010) in its place. Activate the central power unit jumpering the 12V socket cable line; check the vacuum value obtained by the central power unit, which will stop automatically after 15 seconds. Note the value that was reached (value 2).
Check that the difference between values 2 and 1 does not exceed 15 mbar.
If the value is higher, this means that there are leaks that must be found and repaired.
Check 2
Compare value 2 with the vacuum value indicated in the technical features table for the central power unit model that was purchased.
Check that the difference between the two values does not exceed 10% of the table value.
If the value is higher, contact the Aertecnica Service Centre.
Note the values indicated in the table refer to a power supply voltage of 240 V at 50 Hz. If the mains voltage is less, use the following formula: every 10 volt = 10 mbar (example with the TP1 central power unit: 270 mbar at 240 V = 250 mbar at 220 V).
VACUUM TEST - FOR ALL CENTRAL POWER UNITS
Insert the hose in the furthest socket and activate the central power unit.
For PERFETTO TXA,TPA and TP central power units: the vacuum value will appear on the display; if the value is correct (RANGE between 90 and 170 mbar) OK will be displayed. In this case, the test is positive.
Otherwise, contact the Aertecnica Service Centre.
For CLASSIC TC central power units: insert the vacuum gauge (AT010) in the socket adjacent to the one occupied by the hose; if the vacuum value is correct (RANGE between 100 and 150 mbar) the hand will point to the green zone. In this case, the test is positive. Otherwise, contact the Aertecnica Service Centre.
20 User and maintenance manual
Maintenance
2 - Close the CLEAN BAG by pulling the strips (b) all the way, without unhooking the dust container.
Careful maintenance prolongs the life-time of the central power unit and guarantees better performance.
NOTE
Before starting with any maintenance operation, disconnect the central power unit from the power supply.
b b
The central power unit must not be operated without the filter cartridge inserted. Failure to observe this rule could cause damage to the motor that is not covered by the warranty.
3 - Unhook the container from the support by opening the levers (c) sideways and put it on the ground.
orDinarY Maintenance
FOR PERFETTO TXA, TPA AND TP CENTRAL POWER
UNITS c c
container eMptYing
These central power units indicate the CLEAN BAG filling level on the display.
It is recommended to replace the CLEAN BAG before it reaches it maximum capacity limit.
1 - Rotate both handles (a) upwards simultaneously. The dust container will lower.
4 - Remove the full bag and dispose of it (in compliance with the environmental regulations valid in the country of use) english a a
21
PT
FR
ES
DE
EN
IT
english
clean bag insertion
1 - Open the CLEAN BAG blocking system clamps that are on the bottom of the dust container (d).
Check that the bag tensioner ring is fixed to the dust container under the appropriate joints (e).
Check that the dust container gasket (f) is in the correct position.
d e f
3 - Fold the upper part of the bag inside the bag tensioner ring (k). The CLEAN BAG must adhere to the internal walls of the dust container.
Insert the strips into the handle slots (g) allowing them to come out of the container.
NOTE
Only the strips of the dust container must come out: any overhanging parts of the bag can create anomalous noises and loss of air.
k
2 - Insert the CLEAN BAG in the dust container ensuring that the blue disc (printed on the bottom of the bag) is placed at the centre of the container.
The strips must be levelled with the handles.
NOTE
The dust bag must be inserted so that the strips enter the slots (g) of the dust container handles.
Fold the CLEAN BAG under each clamp pair (1-2) and close them one at the time ensuring that the bottom of the bag is completely fitted inside the blocking system.
4 - Rehook the dust container and close the handles.
1
2
CLEAN BAG
g
22 g
User and maintenance manual
filter cartriDge replaceMent
2 - Unscrew the knob (b) that fastens the cartridge and remove it from its housing
Before starting with any maintenance operation, disconnect the central power unit from the power supply.
It is recommended to replace the filter cartridge every
2-3 years.
This period may change depending on the degree of system use.
ATTENTION
When carrying out this operation, it is easy to come into contact with the dust collected on the cartridge walls.
Before removing the filter cartridge, it is recommended to wear suitable personal protective garments.
b
3 - Insert a new cartridge and tighten the knob completely (b). The alignment system guarantees perfect filter cartridge fastening.
english
These central power units display the filter cartridge clogging level.
The filter cartridge maintenance signal will appear on the central power unit AVI display
NOTE
It is recommended to replace the cartridge when the clogging level indicated on the display exceeds 80%.
1 - Open the dust container rotating the handles (a) b
4 - Rehook the dust container and close the handles.
a a
23
orDinarY Maintenance
ON CLASSIC TC CENTRAL POWER UNITS
3 - Rehook the dust container and close the handles.
Careful maintenance prolongs the life-time of the central power unit and guarantees better performance.
NOTE
Before starting with any maintenance operation, disconnect the central power unit from the power supply.
english
The central power unit must not be operated without the filter cartridge inserted. Failure to observe this rule could cause damage to the motor that is not covered by the warranty.
filter cartriDge replaceMent container eMptYing
This operation is necessary when the full container warning light lights up on the AVT panel.
1 - Rotate both handles (a) upwards simultaneously. The dust container will lower.
Before starting with any maintenance operation, disconnect the central power unit from the power supply.
It is recommended to replace the filter cartridge every
2-3 years.
This period may change depending on the degree of system use.
ATTENTION
When carrying out this operation, it is easy to come into contact with the dust collected on the cartridge walls.
Before removing the filter cartridge, it is recommended to wear suitable personal protective garments.
a a
This operation is necessary when the saturated filter cartridge warning light lights up on the AVT panel.
2 - Empty the dust container in a suitable collection bag or container and dispose of it correctly (in accordance with current environmental standards in the country of use).
1 - Open the dust container rotating the handles (a)
24 User and maintenance manual a a
2 - Unscrew the knob (b) that fastens the cartridge and remove it from its housing
NOTE
Check that the dust container gasket (g) is in good condition and placed correctly.
In case of anomaly call a Technical Service Center.
g b
3 - Insert a new cartridge and tighten the knob completely (b). The alignment system guarantees perfect filter cartridge fastening.
4 - Rehook the dust container and close the handles.
english
USE ONLY ORIGINAL
AERTECNICA SPARE PARTS b
25
filter cartriDge regeneration
(for all central power unit models)
NOTE
To effectively regenerate the saturated cartridge and keep the centralised vacuum system operating, it is recommended to insert a new filter cartridge immediately, restart the system and vacuum the largest dust particles from the saturated cartridge using the system itself.
1 - Vacuum the dust collected on the saturated cartridge walls using the system itself.
english
Periodic filter cartridge regeneration improves overall centralised vacuum system productivity.
With normal system use, the cartridge should be checked every 4 months.
The AVI display for the PERFETTO TXA, TPA and TP series shows the filter cartridge saturation level. It is recommended to regenerate the cartridge in any case when the clogging level indicated on the display exceeds
80%.
2 - After an initial brief cleaning, wash the filter cartridge with a jet of water that is not too strong and remove the dust that penetrated between the walls.
The AVT panel for the CLASSIC TC series shows the saturated filter cartridge indication.
ATTENTION
When carrying out this operation, it is easy to come into contact with the dust collected on the cartridge walls.
Before removing the filter cartridge, it is recommended to wear suitable personal protective garments.
3 - Allow the cartridge to dry completely and check the gasket condition (g) g
CARTRIDGE GASKET CHECK
Check the gasket condition (g) of the filter cartridge.
Replace if damaged.
4 - Make sure that there are not any tears or cuts on the cartridge walls. In this case the damaged cartridge must be replaced with a new one.
USE ONLY ORIGINAL
AERTECNICA SPARE PARTS
26 User and maintenance manual
central power unit Disposal
(for all central power unit models)
IMPORTANT
The material listed below must be divided and stored to be recycled or disposed of in compliance with the environmental regulations valid in the country of use.
At the end of its life cycle, the machine must be disposed of in compliance with current applicable regulations.
The following table specifies the material with which the central power unit is built.
TYPE OF MATERIAL
CENTRAL POWER
UNIT
PRESENCE IN THE
SPECIFIC
Plastic and rubber dust container, bag tensioner ring
30% talc polypropylene filled cover, cup, tangential openings, AVT panel, cone, document holder under motor gasket thermoplastic rubber
PRECISION filter cartridge polyester + ABS fastening bracket antivibration bracket rubber sleeves wiring clamps, air exhaust grilles and caps polypropylene
30% glass filled nylon rubber
SBR/NR rubber nylon adhesives, Clean Bag hooks, handles
PVC
PP +nylon gaskets mousse and pivilene silencer polystyrene
Galvanised components screws and rivets
Windings electric motor and wiring galvanized steel copper
Electrical components
Metal components electronic card turbine motor
AVI display
AVT panel electric wires socket cable line schuko plug upper body misc material misc material misc material misc material copper copper copper painted steel, stainless steel
Packaging clamps and pivots box interpads bags galvanized steel cardboard cardboard polyethylene
DISPOSAL
The regulations that govern the disposal and demolition of the central power unit, its components and the possible polluting material and substances change depending on the country of final use.
It is recommended to contact organisations authorised and agencies and to respect the current applicable legal regulations english
27
ANOMALY AND LOCK TABLE
- (for PERFETTO TXA, TPA and TP central power units) english
MAINTENANCE
CLEAN BAG FILLING
LEVEL OF USE
these symbols appear
1 - filling 25-49%
2 - filling 50-74%
3 - filling 75-99% system operates normally
ANOMALY
these symbols appear
+
4 - filling 100%
LOCK
--
INTERVENTION
Ø necessary replace the bag.
After replacing the bag: press MEN three times in a row.
"C" will appear with the number of hours of bag use.
Press RESET to reset use.
Press OK to exit the procedure
FILTER CARTRIDGE
SATURATION
TOO MANY STARTS these symbols appear
1 - saturation 20 - 39 %
2 - saturation 40 - 59 % this symbol flashes these symbols appear
+ appears
If cartridge replacement/regener ation occurs before the lock, the warning light will reset automatically the next time the central power unit is turned on.
3 - saturation 60 - 79 %
4 - saturation 80
- 99 % system operates normally
-this symbol flashes
5 consecutive starts of the central power unit in 1 minute appears
5 - saturation
100%
If the central power unit is locked, replace or regenerate the filter cartridge.
Press RESET to reset use. these symbols appear
+ appears
If the central power unit has an anomaly, proceed with normal cleaning without turning off the system yet. After 1 minute of system use, the warning light will turn off on its own.
appears with 6 consecutive starts of the central power unit in
1 minute
If the central power unit is locked, press
RESET to reset use.
28 User and maintenance manual
MAINTENANCE
MAXIMUM TIME
OF CONTINUOUS
USE
MAXIMUM
VACUUM
EXCESSIVE
TEMPERATURE IN
THE MOTOR
CHAMBER
LEVEL OF USE
--
--
ANOMALY
this symbol flashes
29 consecutive minutes of continuous use
LOCK
this symbol flashes appears appears h
INTERVENTION
If the central power unit has an anomaly, turn off the system to prevent it from locking.
The central control unit will reset itself for use.
If the central control unit is locked, press
RESET or remove and reinsert the hose or turn the system off and on using the switch on the hose.
english this symbol flashes this symbol flashes appears the operating vacuum exceeded
240 mbar
HI appears mbar
If the central control unit has an anomaly, reduce the intake within 15 seconds to prevent it from locking.
If the central control unit is locked, press
RESET to reset use or remove and reinsert the hose or turn the system off and on using the switch on the hose.
this symbol appears motor temperature has exceeded
80°C these symbols appear
+
If the central control unit has an anomaly, reduce the intake within 15 seconds to prevent it from locking.
appears
¡C
If the central control unit has locked, wait for the motor temperature to cool down to 55°C.
After the motor has cooled down, press
RESET to reset use.
29
troublesHooting -
(for PERFETTO TXA, TPA and TP central power units) english
PROBLEM
There is no air intake from all the sockets
CAUSE
Power supply cable disconnected
12V socket cable line not connected or incorrectly connected
The number of consecutive central power unit starts within a period of 1 minute was exceeded
The maximum amount of time of continuous central power use has been exceeded
The motor overheated.
The motor temperature exceeded 80 °C.
The vacuum exceeded 240 mbar for more than 15 seconds
SOLUTION
Connect the power supply cable
Connect the 12V socket cable line or check the wiring
Check the electric connection on each socket.
Press RESET to reset operation
The electric contacts in the hose are dirty.
Clean them as indicated in the accessory instructions.
Press RESET to reset operation
The microswitch in a vacuum socket is damaged.
Call a specialised technician.
The system remained on inadvertently for 30 consecutive minutes.
Press RESET or turn the system off and on to reset operation
Check the electric connection of the 12V socket cable line.
Call a specialised technician.
Check if the air exhaust line is free or if the two air exhaust openings are blocked. Wait for the motor to cool down. Press RESET to reset operation
Make sure the filter cartridge is not saturated. In this case, perform maintenance. Wait for the motor to cool down.
Press RESET to reset operation
The hose inlet is obstructed.
Free the hose, turn the system on and off and press RESET
Rehook the container correctly.
There is no air intake from a socket
The dust container is not correctly hooked
The microswitch or the electric contacts in a vacuum socket are damaged.
Call a specialised technician.
30 User and maintenance manual
PROBLEM CAUSE
There is clogging in the system
SOLUTION
Call a specialised technician.
Low amount of air intake
The filter cartridge is saturated
Multiple vacuum sockets are being used at the same time on the system
The dust container gasket is damaged or out of position
The air exhaust line is clogged
Perform cartridge maintenance. Press
RESET to reset operation.
The central power unit may only be used by one operator at a time.
Check the position of the dust container gasket.
Check if the air exhaust line is free or if two air exhaust openings are blocked.
The hose is partially obstructed.
Free the obstruction from the hose.
The cap was not inserted correctly into the dust inlet not being used in the central power unit
Check that the dust inlet that is not being used is closed with the special cap.
The built-in vacuum socket is damaged Call a specialised technician.
The central power unit always remains activated even with the sockets closed
The microswitch or the electric contacts in a vacuum socket are damaged.
Call a specialised technician.
The AVT panel remains off
The central power unit power supply cable is disconnected
The protective fuse burnt out.
Connect the power supply cable.
Call a specialised technician.
The electronic card is defective.
Call a specialised technician.
Call a specialised technician for other causes that are not covered in this manual english
anoMalY anD locK table
- (for CLASSIC TC central power units)
MAINTENANCE
MAXIMUM
VACUUM
SIGNAL
The symbols blink
LOCK INTERVENTION
The central power unit is locked because the operating vacuum exceeded 240 mbar.
The central power unit is locked because the airflow is not sufficient.
After the maintenance press the
PRESS RESET button to switch off the lock signal and reset to normal use.
EXCEEDING
TEMPERATURE
IN THE MOTOR
CHAMBER
The symbols blink The central power unit is locked because the temperature of the motor chamber exceeded 80 °C.
Wait until the temperature of the motor lowers below 55°C. When this value is reached the PRESS
RESET light lights up and the motor can be restarted.
31
troublesHooting -
(for CLASSIC TC central power units) english
PROBLEM
There is no air intake from all the sockets
CAUSE
Power supply cable disconnected
12V socket cable line not connected or incorrectly connected
The motor overheated.
The motor temperature exceeded 80 °C.
SOLUTION
Connect the power supply cable
Connect the 12V socket cable line or check the wiring
Check if the air exhaust line is free or if the two air exhaust openings are blocked. Wait for the motor to cool down. Press RESET to reset operation
Make sure the filter cartridge is not saturated. In this case, perform maintenance. Wait for the motor to cool down.
Press RESET to reset operation
Rehook the container correctly.
There is no air intake from a socket
The dust container is not correctly hooked
The microswitch or the electric contacts in a vacuum socket are damaged.
Low amount of air intake
There is clogging in the system
Call a specialised technician.
Call a specialised technician.
The filter cartridge is saturated
Multiple vacuum sockets are being used at the same time on the system
The dust container gasket is damaged or out of position
The air exhaust line is clogged
Perform cartridge maintenance. Press
RESET to reset operation.
The central power unit may only be used by one operator at a time.
Check the position of the dust container gasket.
Check if the air exhaust line is free or if two air exhaust openings are blocked.
The hose is partially obstructed.
Free the obstruction from the hose.
The cap was not inserted correctly into the dust inlet not being used in the central power unit
Check that the dust inlet that is not being used is closed with the special cap.
The central power unit always remains activated even with the sockets closed
The microswitch or the electric contacts in a vacuum socket are damaged.
Call a specialised technician.
The AVT panel remains off
The central power unit power supply cable is disconnected
The protective fuse burnt out.
The electronic card is defective.
Connect the power supply cable.
Call a specialised technician.
Call a specialised technician.
Call a specialised technician for other causes that are not covered in this manual
32 User and maintenance manual Maintenance
It is prohibited to use the central power unit for uses other than those described in this manual.
The descriptions and technical illustrations may change. Aertecnica S.p.A. reserves the right to modify the product and the related technical documentation without incurring any obligation to third parties.
This version of the user instruction and maintenance manual describes the features relative to the central power unit in standard production on the date on which this publication was licensed for printing.
8001136/2_rev 1-14
AERTECNICA S.p.A.
Via Cerchia di Sant’Egidio, 760
47521 Cesena (FC) - ITALY
Tel. +39 0547 637311
Fax +39 0547 631388 [email protected]
www.aertecnica.com
Advertisement
Key Features
- Compact size and lightweight construction for easy installation in tight spaces
- Powerful motor for exceptional suction power
- Advanced filtration system effectively traps dust, allergens, and other airborne particles
- Automatic start/stop function for added convenience
- Low noise operation for a quieter cleaning experience
- Large dust container capacity for less frequent emptying
- Durable construction for long-lasting performance