ABB 83350-500; 83350-515 Instructions

Add to My manuals
17 Pages

advertisement

ABB 83350-500; 83350-515 Instructions | Manualzz

1473-1-8646 │ 17.11.2014

Technical Manual

ABB-Welcome

Telephone Gateway

83350-500

83350-515

ABB-Welcome Content

1 Safety ____________________________________________________________________________ 3

2 Environment _______________________________________________________________________ 3

2.1

Disposal _____________________________________________________________________________ 3

3 Technical data ______________________________________________________________________ 4

4 General function ____________________________________________________________________ 5

4.1

Glossary ____________________________________________________________________________ 5

4.2

Functioning __________________________________________________________________________ 6

5 Connection ________________________________________________________________________ 7

5.1

Integration of the Telephone Gateway in your telephone system _________________________________ 7

5.2

Device overview ______________________________________________________________________ 8

6 Mounting / Installation ________________________________________________________________ 9

6.1

Requirements for the electrician __________________________________________________________ 9

6.2

Mounting ____________________________________________________________________________ 9

6.3

System security ______________________________________________________________________ 10

7 Commissioning ____________________________________________________________________ 11

7.1

Commissioning via telephone ___________________________________________________________ 11

8 Operation _________________________________________________________________________ 13

9 Tones for indication _________________________________________________________________ 15

10 Appendix _________________________________________________________________________ 16

10.1

Frequently-used commisioning __________________________________________________________ 16

10.2

Main commands of operation ___________________________________________________________ 16

Technical Manual 1473-1-8646 │ 2

ABB-Welcome

1 Safety

Warning

Electric voltage!

Risk of death and fire due to electric voltage of 230 V.

» Work on the 230V supply system may only be performed by authorised electricians!

» Disconnect the mains power supply prior to installation and/or disassembly!

2 Environment

Safety

Consider the protection of the environment!

Used electric and electronic devices must not be disposed of with domestic waste.

» The device contains valuable raw materials which can be recycled. Therefore, dispose of the device at the appropriate collecting depot.

2.1 Disposal

All packaging materials and devices bear the markings and test seals for proper disposal. Always dispose of the packaging material and electric devices and their components via the authorized collecting depots and disposal companies.

The products meet the legal requirements, in particular the laws governing electronic and electrical devices and the REACH ordinance.

(EU Directive 2002/96/EC WEEE and 2002/95/EC RoHS)

(EU REACH ordinance and law for the implementation of the ordinance (EC)

No.1907/2006).

Technical Manual 1473-1-8646 │ 3

ABB-Welcome

3 Technical

General

Single-wire clamps

Fine-wire clamps

Telephone line clamps

Bus voltage

Size

Protection

Operating temperature

2 x 0,6 mm² – 2 x 1 mm²;

2 x 0,6 mm² – 2 x 0,75 mm²;

0.2 mm²-1,5 mm²

28 V- ±2 V

4 TE

IP20

-5 °C – +45 °C

Technical data

Technical Manual 1473-1-8646 │ 4

ABB-Welcome

4 General

General function

The 83350 Telephone Gateway is part of the Welcome door communication system and operates exclusively with components from this system.

The product serves for connecting a telephone system to a Welcome system, so that the connected telephones will act as audio indoor stations.

For using the Telephone Gateway it is necessary to configure the device as an analogue subscriber of your telephone system.

4.1 Glossary

1. Default phone number: when the Default phone number is active,call for all

Indoor Stations will be redirected to this Default phone number.

2. Primary and secondary phone number: when Primary or secondary phone number is active for an Indoor Station, calls for this Indoor Station will be redirected to this Primary or secondary phone number. It is possible to toggle between these two numbers.

3. Direct-accept: When this function is active, a user can answer a door call directly by picking up the handset. If deactivated, the user has to press the keys [1] [#] after picking up the handset. If other indoor stations than the telephone gateway itself are installed in an apartment, the direct accept function has to be deactivated.

4. Admin PIN: this PIN is used as an administrator password to access the programming mode of the telephone gateway where the Default phone number, Direct-accept feature etc, can be set. It’s suggested that only the administrator knows this PIN.

5. Master PIN: this PIN is used to activate/deactivate the Default phone number for all Indoor Stations. It’s suggested that e.g. the receptionist of a company knows this PIN.

6. Indoor Station PIN: this PIN is used as an enduser password to protect your telephone gateway from misuse or unauthorized access e.g. toggling between primary and secondary target phone number or calling an outdoor station to open the door. This PIN has to be activated if this additional security level is required.

Default admin PIN Default master PIN Default indoor station PIN

1234 0000 1111

Technical Manual 1473-1-8646 │ 5

ABB-Welcome General function

4.2 Functioning

The Telephone Gateway is an analogue subscriber of your telephone system.

The device includes a telephone book, in which every indoor station address (bell button) is linked to up to two telephone numbers (Primary and secondary number). Additionally a default phone number can be programmed. When the Default phone number is active,calls for all Indoor Stations will be redirected to this default phone number.

The telephone book can contain internal or external numbers.

Indoor station address

(bell button)

01

Telephone number 2

(Primary phone number)

9764

Telephone number 3

(Secondary phone number)

00493895555

02

03

0389364860

00493896666

1220

Technical Manual 1473-1-8646 │ 6

ABB-Welcome

5 Connection

Connection

Fig. 1

No. Function

1 Terminals for Welcome system

2

Terminals (Telephoneline clamps) for Private Branch Exchange (PBX) in telephone system.

Note...

The telephone gateway is always set as master. The related indoor stations in the same appartment have always to be set as slave (Please refer to the operating manual of the indoor stations.).

5.1 Integration of the Telephone Gateway in your telephone system

The procedure of integrating the Thelephone Gateway into your system depends on the telephone system and can vary. Please refer to the topic “Integration of analogue subscribers” in the manual of your telephone system.

The integration of the Telephone Gateway is succsessfull, if it can be called by other participants and can call others by itself.

Note...

System security

» Avoid misuse by intruders and configure your telephone system in a way, that the Telephone Gateway can not directly be called from an external telephone. This will prevent unauthorised access of intruders.

» If it is necessary to have external access to the Gateway, please activate the indoor station PIN (See Page 11 “Commissioning“).

Technical Manual 1473-1-8646 │ 7

ABB-Welcome

5.2 Device

Connection

No. Function

1

2

Operation status of connection to PBX

: Connected to PBX (idle or ongoing call)

: a. Ringing

Operation status of Welcome bus

: Ready for operation. Bus voltage is applied.

: a. Receiving data

1+2 : Reset to factory defaults ongoing

3

4

5

USB port for software update (can only be done in the factory).

In pure audio installations the terminal resistor must always be deactivated ('OFF'). In video installations or mixed audio and video installations the terminal resistor must be activated on the last device of a branch ('ON').

Long-press 3s to reset the device to factory settings. Both LEDs will flash, if reset function is performed. Below are the original factory settings:

- Master PIN: 0000

- Admin PIN: 1234

- Indoor Station PIN: 1111

- Direct-accept: OFF

- Default phone number: empty

- Primary phone number: empty

- Secondary phone number: empty

- Call diverted to Default phone number: OFF

- Indoor Station PIN required: OFF

Technical Manual 1473-1-8646 │ 8

ABB-Welcome

6 Mounting / Installation

Mounting / Installation

Warning

Electric voltage!

Risk of death and fire due to electric voltage of 230 V.

» Low-voltage and 230 V cables must not be installed together in a flush-mounted socket!

Warning

Electric voltage!

» The upstream fuse must be disconnected when working on the lighting system

6.1 Requirements for the electrician

Warning

Electric voltage!

Incorrect installation endangers your life and that of the user of the electrical system.

Incorrect installation can cause serious damage to property, e.g. due to fire.

» Install the device only if you have the necessary electrical engineering knowledge and experience.

The minimum necessary expert knowledge and requirements for the installation are as follows:

» Apply the "five safety rules" (DIN VDE 0105, EN 50110):

1. Disconnect the power;

2. Secure against being reconnected;

3. Ensure there is no voltage;

4. Connect to earth;

5. Cover or barricade adjacent live parts.

» Use suitable personal protective clothing.

» Use only suitable tools and measuring devices.

» Check the type of supply network (TN system, IT system, TT system) to secure the following power supply conditions (classic connection to ground, protective earthing, necessary additional measures, etc.).

6.2 Mounting

The device must only be installed on mounting rails according to DIN EN 50022.

Technical Manual 1473-1-8646 │ 9

ABB-Welcome Mounting / Installation

6.3 System

Avoid misuse by intruders and configure your telephone system in a way, that the

Telephone Gateway can not directly be called from an external telephone. This will prevent unauthorised access of intruders.

If it is necessary to have external access to the Gateway, please activate the indoor station PIN (See Page 11 “Commissioning“).

Technical Manual 1473-1-8646 │ 10

ABB-Welcome

7 Commissioning

Commissioning

7.1

The following components are required to operate the Telephone Gateway:

- A Welcome door communication system including the System Controller and at least one Outdoor station.

- A PBX with analogue input

- At least one telephone for configuring via DTMF

For the initial startup of the Telephone Gateway, a few basic settings need to be made. Two options are available for commissioning:

- Via telephone, connected to the system

- Via Internet browser and IP-Gateway 83342-xxx. For configuring the Telephone Gateway via the IP Gateway, please see the manual of the IP Gateway.

Commissioning via telephone

1. Call the telephone gateway via your PBX.

Admin

No. Function

Enter Admin PIN

1

Command

[*] [*] [*] Admin PIN [#]

Example or explanation

The default Admin PIN is 1234

Technical Manual 1473-1-8646 │ 11

ABB-Welcome Commissioning

3. If the Admin PIN is correct, the telephone gateway enters the programming mode and the settings can be done as followed:

No. Function

1

Set Default phone number

Command

[7] [3] [6] [*] Default phone number

[#]

Example or explanation

2

3

4

5

6

7

8

9

10

11

12

13

14

Add a new Indoor

Station to phonebook

Add a range of indoor stations phone book

Add or change the

Primary and Secondary phone number

Add or change the primary phone number in the phonebook

Activate “Directaccept” Feature

[2] [4] [7] [*] Indoor Station Number

[#]

[2] [4] [7] [7] [*] Indoor Station

Number 1 [*] Indoor Station Number 2 [#]

[2] [*] Indoor Station Number [*]

Primary phone number [*] Secondary phone number [#]

[2] [*] Indoor Station Number [*]

Primary phone number [#]

The Indoor Station Number can be 1 (or 01) to

99.

Indoor station number 2 must always be greater than station number 1.

[7] [3] [2] [1] [#]

To be used if the user does not want to provide a Secondary phone number

Deactivate “Directaccept” Feature

[7] [3] [2] [0] [#] If there are Indoor Stations in system, this function should be activated.

Set New Admin PIN

Set New Master PIN

[7] [*] [*] [*] New Admin PIN [*] [*]

[*]

New Admin PIN [#]

[7] [*] [*] New Master PIN [*] [*] +

New Master PIN [#]

Activate mandatory usage of Indoor Station PIN

Deactivate mandatory usage of Indoor Station PINs

Set New Indoor Station PINs

[7] [4] [7] [1] [#]

[7] [4] [7] [0] [#]

[*] Indoor Station Number [*] [7] [*]

New Indoor Station PIN [*]

New Indoor Station PIN [#]

[7] [4] [3] [*] Identifier [*] Identifier

[#]

Set Telephone Gateway Identifier for programming via IP Gateway and PC.

Reset to Factory Setting

[7] [3] [7] [8] [*] Admin PIN [#]

Identifier should be an integer from 1 to 99, and has to be unique.

Technical Manual 1473-1-8646 │ 12

ABB-Welcome

8 Operation

Operation

After Programming, users can use a telephone to call the Telephone Gateway.

When there is a call-in from Outdoor Station, and telephone is in normal standby:

No. Function Command Example or explanation

1 Accept Call-in [1] [#]

Commands below can be done via telephone when there is ongoing conversation between Outdoor Station and telephone:

No. Function Command Example or explanation

To turn on the light switch of the

System Controller or the door actuator

Open door during conversation with Outdoor Station

When there is no ongoing conversation between Outdoor Station and telephone, user calls the Telephone Gateway, then

1. When Call Divert to Default phone number is active, the telephone will play

“Calls are diverted” tone;

2. When Call Divert to Default phone number is not active, the telephone will play “Calls are not diverted” tone.

3. Settings below can be done via telephone:

No. Function

1

3

4

5

Call Outdoor Station

Switch Light when

Indoor Station PIN is must

Open Specific Door

Open Special Door when Indoor Station

PIN is must

Command

[1] [1] [#] to [1] [4] [#] or [1] [#]

[5] [#]

[5] [1] [#] to [5] [9] [#]

[*] Indoor Station Number [*]

Indoor Station PIN [*] [5] [#]

[*] Indoor Station Number [*]

Indoor Station PIN [*] [5] [1]

[#] to [5] [9] [#]

[3] [1] [#] to [3] [4] [#]

[*] Indoor Station Number [*]

Indoor Station PIN [*] [3] [1]

[#] to [3] [4] [#]

Example or explanation

- 11#--14# to call a special

Outdoor Station

- 1# is also allowed; this will call the Outdoor Station 1

To turn on the light switch of the System Controller or the door actuator

To be used for the light switch that triggers a specific light, connected to the flushmounted actuator

To trigger the light switch of the System Controller and the door actuator

To be used for the light switch that triggers a specific light, connected to the flushmounted actuator

To open special door of the

System Controller and the door actuator

To open special door of the

System Controller and the door actuator

Technical Manual 1473-1-8646 │ 13

ABB-Welcome

6

7

8

9

10

11

12

13

14

15

16

17

18

Open the last door-in

Outdoor Station

Open the last door-in

Outdoor Station when

Indoor Station PIN is must

[3] [0] [#]

[*] Indoor Station Number [*]

Indoor Station PIN [*] [3] [0]

[#]

Call Outdoor Station when Indoor Station

PIN is must

[*] Indoor Station Number [*]

Indoor Station PIN [*] [1] [1]

[#] to [1] [4] [#] or

[*] Indoor Station Number [*]

Indoor Station PIN [*] [1] [#]

Call the last call-in

Outdoor Station

Call the last call-in

Outdoor Station when

Indoor Station PIN is must

[1] [0] [#]

[*] Indoor Station Number [*]

Indoor Station PIN [*] [1] [0]

[#]

Activate Default target phone number

[*] Indoor Station Number [*]

[6] [0] [#]

Activate Default target phone number when

Indoor Station PIN is must

[*] Indoor Station Number [*]

Indoor Station PIN [*] [6] [0]

[#]

[*] Indoor Station Number [*]

[6] [1] [#]

Activate Primary target phone number

Activate Primary target phone number when Indoor Station

PIN is must

Activate Secondary target phone number

[*] Indoor Station Number [*]

Indoor Station PIN [*] [6] [1]

[#]

[*] Indoor Station Number [*]

[6] [2] [#]

Activate Secondary target phone number when Indoor Station

PIN is must

[*] Indoor Station Number [*]

Indoor Station PIN [*] [6] [2]

[#]

Set new Indoor Station PIN

[*] Indoor Station Number [*]

Indoor Station PIN [*] [7] [*]

New Indoor Station PIN [*]

New Indoor Station PIN [#]

Activate Call Divert to

Default phone number

[*] [*] Master PIN [*] [6] [0] [#]

19

Deactivate Call Divert to Default phone number

[*] [*] Master PIN [*] [6] [9] [#]

Operation

To call a special Outdoor

Station

1# is also allowed; this will call the Outdoor Station 1

Technical Manual 1473-1-8646 │ 14

ABB-Welcome

9 Tones for indication

No. Function

1 Successfull

Command

Call

4

Call Divert active

(repeating)

5

Call Divert not active

(repeating)

6

Programming Mode

(repeating)

Tones for indication

Example or explanation

Confirmation of a successfull operation

Notification of a not successfull operation

Doorcall waiting (only when direct accept feature is deactivated, because further inddorstations in same appartment)

Call divert to the default number is active. Tone is heard after calling the telephone gateway.

Call divert to the default number is deactivated.

Tone is heard after calling the telephone gateway.

Telephone gateway is in programming mode

Technical Manual 1473-1-8646 │ 15

ABB-Welcome

10 Appendix

Appendix

Use case: One apartment with one telephone + one telephone gateway.

User uses phone to call Telephone Gateway firstly, then:

No. Function

Enter Admin PIN

Step

1

Command

[*] [*] [*] + Admin PIN + [#]

Example or explanation

The default Admin PIN is

1234

Step

2

Set Default phone number

Step

3

Add a new Indoor

Station to Telephone

Gateway phonebook

Step

4

Set Primary/Secondary phone number

[7] [3] [6] [*] + Default phone number + [#]

[2] [4] [7] [*] + Indoor Station Number + [#]

[2] [*] + Indoor Station Number [*] +

Primary phone number + [*] + Secondary phone number + [#]

Indoor Station Number could be one digit or two digits, such as 1 or 01 to

99

10.2 Main commands of operation

When there is a call-in from Outdoor Station, and telephone is in normal standby:

No. Function Command Example or explanation

1 Accept Call-in [1] [#]

When there is no ongoing conversation between Outdoor Station and telephone, user calls the Telephone Gateway:

No. Function Command Example or explanation

[1] [1] [#] to [1] [4] [#] or [1] [#] or

[1] [0] [#]

- 11#--14# to call a special Outdoor Station

- 1# is also allowed; this will call the Outdoor

Station 1

- 10# to call the OS from which the last call has been made

Commands below can be done via telephone when there is ongoing conversation between Outdoor Station and telephone:

No. Function Command Example or explanation

To turn on the light switch of the System

Controller or the door actuator

Open door during conversation with Outdoor

Station

Technical Manual 1473-1-8646 │ 16

ABB-Welcome

A member of the ABB Group

Busch-Jaeger Elektro GmbH

PO Box

58505 Lüdenscheid

Freisenbergstraße 2

58513 Lüdenscheid www.BUSCH-JAEGER.com [email protected]

Central sales service:

Tel.: +49 2351 956-1600

Fax: +49 2351 956-1700

Note

We reserve the right to at all times make technical changes as well as changes to the contents of this document without prior notice.

The detailed specifications agreed upon apply for orders. ABB accepts no responsibility for possible errors or incompleteness in this document.

We reserve all rights to this document and the topics and illustrations contained therein. The document and its contents, or extracts thereof, must not be reproduced, transmitted or reused by third parties without prior written consent by ABB.

Copyright © 2014 Busch-Jaeger

Elektro GmbH

All rights reserved

advertisement

Related manuals