ABB 83310-500; 83310-515 Product Manual

Add to My manuals
9 Pages

ABB 83310-500 auxiliary power supply is a device used to power and support door communication systems. It's designed to work exclusively with components from the ABB-Welcome system and must be installed on mounting rails according to DIN EN 500022. The device features a switch for the terminal resistor, a status LED, and connections for the system controller, indoor stations, and power supply.

advertisement

ABB 83310-500; 83310-515 Product Manual | Manualzz

0073-1-7524 │ │ 22.02.2012

ABB-Welcome

Pos: 2 /DinA4 - Anleitungen Online/Inhalt/KNX/DoorEntry/83310/Titelblatt - 83310 - ABB @ 19\mod_1323174018866_15.docx @ 111018 @ @ 1

83310-500

83310-515

Auxiliary power supply

=== Ende der Liste für Textmarke Cover ===

ABB-Welcome

Pos: 4 /Busch-Jaeger (Neustruktur)/Modul-Struktur/Online-Dokumentation/Inhaltsverzeichnis (--> Für alle Dokumente <--)/Inhaltsverzeichnis @ 19\mod_1320649044386_15.docx @ 109653 @ @ 1

1 Safety ....................................................................................................................................................................... 3

2 Intended use ............................................................................................................................................................ 3

3 Environment ............................................................................................................................................................. 3

3.1

ABB devices ............................................................................................................................................ 3

4 User Manual............................................................................................................................................................. 3

5 Operation ................................................................................................................................................................. 4

5.1

5.2

Standard operation ................................................................................................................................. 4

Adjusting the device ................................................................................................................................ 5

5.2.1

Terminal resistor ..................................................................................................................................... 5

6 Technical data.......................................................................................................................................................... 6

7 Mounting / Installation .............................................................................................................................................. 7

7.1

7.2

7.3

7.4

Requirements for the electrician ............................................................................................................. 7

General installation instructions .............................................................................................................. 7

Mounting ................................................................................................................................................. 8

Connection .............................................................................................................................................. 8

=== Ende der Liste für Textmarke TOC ===

| 0073-1-7524 — 2 —

ABB-Welcome

Pos: 6 /Busch-Jaeger (Neustruktur)/Modul-Struktur/Online-Dokumentation/Überschriften (--> Für alle Dokumente <--)/1. Ebene/S - T/Sicherheit @ 18\mod_1302612791790_15.docx @ 103357 @ 1 @ 1

1 Safety

Safety

Pos: 7 /Busch-Jaeger (Neustruktur)/Modul-Struktur/Online-Dokumentation/Sicherheit (--> Für alle Dokumente <--)/Warnhinweise/Sicherheit - 230 V @ 18\mod_1302606816750_15.docx @ 103308 @ @ 1

Warning

E lec tric voltage!

Risk of death and fire due to electrical voltage of 230 V.

– Work on the 230V supply system may only be performed by authorised electricians!

– Disconnect the mains power supply prior to installation and/or disassembly!

Pos: 8 /Busch-Jaeger (Neustruktur)/Modul-Struktur/Online-Dokumentation/Überschriften (--> Für alle Dokumente <--)/1. Ebene/A - F/Bestimmungsgemäßer Gebrauch @ 18\mod_1302763321316_15.docx @ 103483 @ 1 @ 1

2 Intended use

Pos: 9 /DinA4 - Anleitungen Online/Inhalt/KNX/DoorEntry/83310/Bestimmungsgemaesser Gebrauch - 83310-500 @ 19\mod_1323173967290_15.docx @ 111009 @ @ 1

The 83310-500 auxiliary power supply is an integral part of the ABB-Welcome door communication system and operates exclusively with components from this system. The device must only be installed on mounting rails according to DIN EN 500022.

Pos: 10 /Busch-Jaeger (Neustruktur)/Modul-Struktur/Online-Dokumentation/Überschriften (--> Für alle Dokumente <--)/1. Ebene/U - Z/Umwelt @ 18\mod_1302614158967_15.docx @ 103383 @ 1 @ 1

3 Environment

Pos: 11 /Busch-Jaeger (Neustruktur)/Modul-Struktur/Online-Dokumentation/Umwelt (--> Für alle Dokumente <--)/Hinweise/Hinweis - Umwelt - Hinweis Elektrogeräte @ 18\mod_1302763973434_15.docx @ 103500 @ @ 1

C ons ider the protec tion of the environment!

Used electric and electronic devices must not be disposed of with domestic waste.

– The device contains valuable raw materials which can be recycled. Therefore, dispose of the device at the appropriate collecting depot.

Pos: 12 /DinA4 - Anleitungen Online/Ueberschriften/2./ABB Geraete @ 19\mod_1323162843832_15.docx @ 110875 @ 2 @ 1

3.1

A B B devic es

Pos: 13 /Busch-Jaeger (Neustruktur)/Modul-Struktur/Online-Dokumentation/Umwelt (--> Für alle Dokumente <--)/Hinweise/Hinweis - Umwelt - ABB Elektrogeräte @ 19\mod_1323162745839_15.docx @ 110867 @ @ 1

All packaging materials and devices from ABB bear the markings and test seals for proper disposal. Always dispose of the packaging material and electric devices and their components via the authorized collecting depots and disposal companies.

ABB products meet the legal requirements, in particular the laws governing electronic and electrical devices and the REACH ordinance.

(EU-Directive 2002/96/EG WEEE and 2002/95/EG RoHS)

(EU-REACH ordinance and law for the implementation of the ordinance (EG) No.1907/2006)

Pos: 14 /DinA4 - Anleitungen Online/Ueberschriften/1./Anwenderhandbuch @ 19\mod_1309347227593_15.docx @ 107473 @ 1 @ 1

4 User Manual

Pos: 15 /DinA4 - Anleitungen Online/Inhalt/KNX/DoorEntry/Systemhandbuch/Anwenderhandbuch - ABB @ 19\mod_1323163157997_15.docx @ 110883 @ @ 1

Detailed information for planning ABB-Welcome systems is contained in the user manual. Download at www.Busch-Jaeger.com.

Pos: 16 /Busch-Jaeger (Neustruktur)/Modul-Struktur/Online-Dokumentation/Steuermodule - Online-Dokumentation (--> Für alle Dokumente <--)/++++++++++++ Seitenumbruch ++++++++++++ @ 9\mod_1268898668093_0.docx @ 52149 @ @ 1

| 0073-1-7524 — 3 —

ABB-Welcome

Pos: 17 /DinA4 - Anleitungen Online/Ueberschriften/1./Bedienung @ 18\mod_1302613924165_15.docx @ 103365 @ 1 @ 1

5 Operation

Pos: 18 /DinA4 - Anleitungen Online/Ueberschriften/2./Normaler Betrieb @ 18\mod_1302768820965_15.docx @ 103540 @ 2 @ 1

5.1

S tandard operation

Pos: 19 /DinA4 - Anleitungen Online/Inhalt/KNX/DoorEntry/83310/Bedienung - 83310 @ 18\mod_1303216853392_15.docx @ 103787 @ @ 1

Operation

Fig. 1:

No.

1

2

3

F unc tion

Switch for the terminal resistor (see also chapter "Terminal resistor" on page 5)

The terminal resistor is switched off.

The terminal resistor is switched on.

Status LED

The status LED lights up permanently = the device is operating

The status LED flashes slowly

The status LED flashes fast

• Connection for the system controller

= the device is operating

= there is an error

• When using several indoor stations: connection for the internal bus

4 Indoor stations (max. 4 pairs of wires)

• Connections for the indoor stations

• When using several indoor stations: connection for the internal bus

5 Power supply

Pos: 20 /Busch-Jaeger (Neustruktur)/Modul-Struktur/Online-Dokumentation/Steuermodule - Online-Dokumentation (--> Für alle Dokumente <--)/++++++++++++ Seitenumbruch ++++++++++++ @ 9\mod_1268898668093_0.docx @ 52149 @ @ 1

| 0073-1-7524 — 4 —

ABB-Welcome

Pos: 21 /DinA4 - Anleitungen Online/Ueberschriften/2./Geraeteeinstellungen @ 18\mod_1302768847744_15.docx @ 103548 @ 2 @ 1

5.2

A djus ting the devic e

Pos: 22 /DinA4 - Anleitungen Online/Ueberschriften/3./Abschlusswiderstand @ 19\mod_1321958079906_15.docx @ 110083 @ 3 @ 1

5.2.1

T erminal res is tor

Pos: 23 /DinA4 - Anleitungen Online/Inhalt/KNX/DoorEntry/Bedienung/Abschlusswiderstand setzen 83310-xxx @ 19\mod_1312372134009_15.docx @ 108373 @ @ 1

Operation

Fig. 2: Setting the terminal resistor on the device

• In pure audio installations always set the terminal resistor (1) on "OFF".

• In video installations or mixed audio and video installations set the terminal resistor for the the last devices of a branch on "ON".

Pos: 24 /Busch-Jaeger (Neustruktur)/Modul-Struktur/Online-Dokumentation/Steuermodule - Online-Dokumentation (--> Für alle Dokumente <--)/++++++++++++ Seitenumbruch ++++++++++++ @ 9\mod_1268898668093_0.docx @ 52149 @ @ 1

| 0073-1-7524 — 5 —

ABB-Welcome

Pos: 25 /DinA4 - Anleitungen Online/Ueberschriften/1./Technische Daten @ 18\mod_1302615863001_15.docx @ 103416 @ 1 @ 1

6 Technical data

Pos: 26 /DinA4 - Anleitungen Online/Inhalt/KNX/DoorEntry/83310/Technische Daten - 83310 @ 18\mod_1303216854283_15.docx @ 103819 @ @ 1

Des ignation

Operating temperature

Storage temperature

Protection

Connection cross section for 230 V

• Single-wire clamps

• Fine-wire clamps

Volume

Mains voltage

V alue

-5° C – + 45° C (EN 50486)

-20° C – +70° C

IP 20

2 x 0.6 mm² – 2 x 1 mm²

2 x 0.6 mm² – 2 x 0.75 mm²

Maximum 80 dB

100-240 V, 50 / 60 Hz, 0.9 A

Indoor stations for direct connection 4

Size 8 TE

28 V- ±2 V Bus voltage

Pos: 27 /Busch-Jaeger (Neustruktur)/Modul-Struktur/Online-Dokumentation/Steuermodule - Online-Dokumentation (--> Für alle Dokumente <--)/++++++++++++ Seitenumbruch ++++++++++++ @ 9\mod_1268898668093_0.docx @ 52149 @ @ 1

Technical data

| 0073-1-7524 — 6 —

ABB-Welcome

Pos: 28 /Busch-Jaeger (Neustruktur)/Modul-Struktur/Online-Dokumentation/Überschriften (--> Für alle Dokumente <--)/1. Ebene/M - O/Montage / Installation @ 18\mod_1302613966111_15.docx @ 103373 @ 1 @ 1

7 Mounting / Installation

Mounting / Installation

Pos: 29 /Busch-Jaeger (Neustruktur)/Modul-Struktur/Online-Dokumentation/Sicherheit (--> Für alle Dokumente <--)/Warnhinweise/Sicherheit - Niederspannungs- und 230 V-Leitungen @ 18\mod_1302617821491_15.docx @ 103465 @ @ 1

Warning

E lec tric voltage!

Risk of death and fire due to electrical voltage of 230 V.

– Low-voltage and 230 V cables must not be installed together in a flush-mounted socket!

In case of a short-circuit there is the danger of a 230 V load on the low-voltage line.

Pos: 30 /Busch-Jaeger (Neustruktur)/Modul-Struktur/Online-Dokumentation/Sicherheit (--> Für alle Dokumente <--)/Warnhinweise/Sicherheit - Fachkenntnisse @ 18\mod_1302774384017_15.docx @ 103564 @ 2 @ 1

7.1

R equirements for the elec tric ian

Warning

E lec tric voltage!

Install the device only if you have the necessary electrical engineering knowledge and experience.

• Incorrect installation endangers your life and that of the user of the electrical system.

• Incorrect installation can cause serious damage to property, e.g. due to fire.

The minimum necessary expert knowledge and requirements for the installation are as follows:

• Apply the "five safety rules" (DIN VDE 0105, EN 50110):

1. Disconnect from power;

2. Secure against being re-connected;

3.

4.

5.

Ensure there is no voltage;

Connect to earth;

Cover or barricade adjacent live parts.

• Use suitable personal protective clothing.

• Use only suitable tools and measuring devices.

• Check the type supply network (TN system, IT system, TT system) to secure the following power supply conditions (classic connection to ground, protective earthing, necessary additional measures, etc.).

Pos: 31 /DinA4 - Anleitungen Online/Inhalt/KNX/DoorEntry/Montage/Montagehinweise - Allgemein @ 19\mod_1310563670478_15.docx @ 107743 @ 2 @ 1

7.2

G eneral ins tallation ins truc tions

• Terminate all branches of the wiring system via a connected bus device (e.g., indoor station, outdoor station, system device).

• Do not install the system controller directly next to the bell transformer and other power supplies (to avoid interference).

• Do not install the wires of the system bus together with 230 V wires.

• Do not use common cables for the connecting wires of the door openers and wires of the system bus.

• Avoid bridges between different cable types.

• Use only two wires for the system bus in a four-core or multi-core cable.

• When looping, never install the incoming and outgoing bus inside the same cable.

• Never install the internal and external bus inside the same cable.

Pos: 32 /Busch-Jaeger (Neustruktur)/Modul-Struktur/Online-Dokumentation/Steuermodule - Online-Dokumentation (--> Für alle Dokumente <--)/++++++++++++ Seitenumbruch ++++++++++++ @ 9\mod_1268898668093_0.docx @ 52149 @ @ 1

| 0073-1-7524 — 7 —

ABB-Welcome

Mounting / Installation

Pos: 33 /Busch-Jaeger (Neustruktur)/Modul-Struktur/Online-Dokumentation/Überschriften (--> Für alle Dokumente <--)/2. Ebene/M - O/Montage @ 18\mod_1302615960458_15.docx @ 103424 @ 2 @ 1

7.3

Mounting

Pos: 34 /DinA4 - Anleitungen Online/Inhalt - Montage/Montage - Hutschienen nach DIN EN 500022 @ 18\mod_1303218164750_15.docx @ 103868 @ @ 1

The device 83310-500 must only be installed on mounting rails according to DIN EN 500022.

Pos: 35 /DinA4 - Anleitungen Online/Ueberschriften/2./Anschluss @ 18\mod_1302617573351_15.docx @ 103449 @ 2 @ 1

7.4

C onnec tion

Pos: 36 /DinA4 - Anleitungen Online/Inhalt/KNX/DoorEntry/83310/Anschluss - 83310 @ 18\mod_1303216853127_15.docx @ 103779 @ @ 1

Fig. 3:

No.

1

2

3

=== Ende der Liste für Textmarke Content ===

F unc tion

• Connection for the system controller

• When using several indoor stations: connection for the internal bus

Indoor stations (max. 4 pairs of wires)

• Connections for the indoor stations

• When using several indoor stations: connection for the internal bus

Power supply

| 0073-1-7524 — 8 —

ABB-Welcome

Pos: 38 /Busch-Jaeger (Neustruktur)/Modul-Struktur/Online-Dokumentation/Rückseiten (--> Für alle Dokumente <--)/Rückseite - Busch-Jaeger - Allgemein @ 20\mod_1327320074886_15.docx @ 137103 @ @ 1

A member of the ABB Group

Busch-Jaeger Elektro GmbH

PO box

58505 Lüdenscheid

Freisenbergstraße 2

58513 Lüdenscheid

Germany www.BUSCH-JAEGER.com [email protected]

Central sales service:

Phone: +49 180 5 669900

Fax:

=== Ende der Liste für Textmarke Backcover ===

+49 180 5 669909

Notice

We reserve the right to at all times make technical changes as well as changes to the contents of this document without prior notice.

The detailed specifications agreed to at the time of ordering apply to all orders. ABB accepts no responsibility for possible errors or incompleteness in this document.

We reserve all rights to this document and the topics and illustrations contained therein. The document and its contents, or extracts thereof, must not be reproduced, transmitted or reused by third parties without prior written consent by ABB.

Copyright© 2012 Busch-Jaeger Elektro GmbH

All rights reserved

advertisement