ABB M2302 Gateway Instructions

Add to My manuals
19 Pages

advertisement

ABB M2302 Gateway Instructions | Manualzz

Pos: 2 /DinA4 - Anl eitun gen Online /Inh alt/KNX/Doo rEntry /832 20-AP- xxx/Tit elblat t - 832 20-AP-xxx - ABB @ 1 9\m od_ 132 3249 806 476 _15. docx @ 11 108 4 @ @ 1

VER: 1.3 | 02.20.2017

ABB Welcome ®

M2302

Gateway

=== E nde der Liste für Tex tma rke C over == =

ABB Welcome ®

Pos: 4 /Busc h-Ja ege r (N eust rukt ur)/ Mo dul-St ruktu r/Onli ne-D oku ment ation /Inh altsve rzeich nis ( --> Fü r alle Doku men te <-- )/In haltsve rzeic hnis @ 19\ mod _13 206 490 4438 6_1 5.d ocx @ 109 653 @ @ 1

1 Safety ....................................................................................................... 3

2 Intended use............................................................................................. 3

3 Environment ............................................................................................. 3

3.1

ABB devices ............................................................................. 3

4 Operation ................................................................................................. 4

4.1

4.2

Control elements ...................................................................... 4

Operating modes ...................................................................... 5

4.2.1

Building gateway ...................................................................... 5

4.2.2

Floor gateway ........................................................................... 7

4.2.3

Apartment gateway ................................................................. 10

4.2.4

Additional power supply mode ................................................. 13

4.2.5

Line amplifier .......................................................................... 15

5 Technical data ........................................................................................ 16

6 Mounting and installation......................................................................... 17

6.1

6.2

6.3

Requirements for the electrician .............................................. 17

General installation instructions ............................................... 17

Mounting ................................................................................ 18

=== E nde der Liste für Tex tma rke TOC == =

— 2 —

ABB Welcome ®

Pos: 6 /Busc h-Ja ege r (N eust rukt ur)/ Mo dul-St ruktu r/Onli ne-D oku ment ation /Übe rschri ften (- -> Für alle D okum ent e < --)/ 1. Eb ene/S - T /Sicher heit @ 18\ mod _13 026 127 917 90_ 15.d ocx @ 103 357 @ 1 @ 1

1

Safety

Warning

Electric voltage!

Direct or indirect contact with live components can cause dangerous currents to flow through the body, which may result in electric shock, burns or even death.

Always disconnect the main power supply prior to installation and/or disassembly.

Work on the 110 V - 240 V supply system must be performed only by qualified personnel.

2 Intended use

This device is an integral part of the ABB Welcome door communication system and operates exclusively with components from this system. The device must only be installed on mounting rails according to DIN EN 500022.

3 Environment

Consider the protection of the environment!

Used electric and electronic devices must not be disposed of with household waste.

– The device contains valuable raw materials that can be recycled and should be disposed of at an appropriate recycling facility.

3.1 ABB devices

All packaging materials and devices from ABB bear the markings and test seals for proper disposal. Always dispose of the packaging material, electronic devices and their components via authorized recycling facilities or disposal companies.

— 3 —

ABB Welcome ®

4 Operation

4.1 Control elements

6

Fig. 1: Overview of control buttons

No.

1

Functions

Bus in and out.

2

3

4

5

Operating mode settings: See chapter “Operating modes” for details.

Terminal resistor ON/OFF.

In video installations or audio- and video-combined installations, the switch must be set as “RC on” on the last device of the line.

Rotary switches for addressing (01-99).

Connection with outdoor stations, or connection with bus in, in “line

Amplifier” mode.

Operating status indicating LED.

— 4 —

ABB Welcome ®

4.2 Operating modes

4.2.1 Building gateway

ON

1 2 3

1

Fig. 2: Building gateway

No. Functions

1 1->OFF, 2->OFF, 3->OFF

— 5 —

Fig. 3: Building gateway

Wiring diagram:

Fig. 4: Building gateway

ABB Welcome ®

Enable one building as an independent subsystem (outdoor station(s) and guard unit(s) can be connected). Up to 60 such systems are supported within the whole system.

The gateway address is equal to the riser number.

— 6 —

ABB Welcome ®

4.2.2 Floor gateway

ON

1 2 3

1

Fig. 5: Floor gateway

No. Functions

1 1->OFF, 2->OFF, 3->ON

— 7 —

ABB Welcome ®

Enable a multi-apartment as an independent subsystem (another outdoor station can be connected, for example, in front of the door of the floor with the multi-apartment).

The gateway address is equal to the minimum address of the indoor station inside the subsystem.

Fig. 6: Floor gateway

Wiring diagram:

Fig. 7: Floor gateway

If you are using a pushbutton outdoor station as a gate station, the floor gateway is suitable for this application.

In the following example, an outdoor station is mounted at the gate entrance, from which all six apartments can be called. One outdoor station is at the left building with apartments 01 and 03, and an additional outdoor station is at the right building with apartments 04 and 05.

This means that only three apartments can be called from these two outdoor stations.Using a floor gateway for each building, outdoor station 1 can manage the two buildings, with outdoor station 2 managing the left building and outdoor station 3 managing the right building.

— 8 —

ABB Welcome ®

Apartment 01 A

Apartment 02 B

Apartment 03 C

Apartment 01 A

Apartment 02 B

Apartment 03 C

Apartment 04 D

Apartment 05 E

Apartment 06 F

Apartment 04 A

Apartment 05 B

Apartment 06 C

Outdoor station

Left building

Outdoor station

Gate entrance

Outdoor station

Right building

Wiring diagram (using floor gateway for each building)

ST. X100 X10 X1

2 0 0 3

ST. X100 X10 X1

2 0 0 2

ST. X100 X10 X1

2 0 0 1

Address

2

Address

1

Address

3

ST. X100 X10 X1

3 0 0 4

ST. X100 X10 X1

3 0 0 5

ST. X100 X10 X1

3 0 0 6

Apartment 01 A

Apartment 02 B

Apartment 03 C

Apartment 01 A

Apartment 02 B

Apartment 03 C

Apartment 04 D

Apartment 05 E

Apartment 06 F

Apartment 04 A

Apartment 05 B

Apartment 06 C

M2302

X10 X1

0 1

M2302

X10 X1

0 4

— 9 —

ABB Welcome ®

4.2.3 Apartment gateway

ON

1 2 3

1

Fig. 8: Apartment gateway

No. Functions

1 1->OFF, 2->ON, 3->OFF

— 10 —

ABB Welcome ®

Enable one apartment as an independent subsystem (A second confirmed outdoor station can be connected). Up to 99 such systems can be supported within the whole system. The gateway address is equal to the apartment number.

Fig. 9: Apartment gateway

— 11 —

ABB Welcome ®

Wiring diagram:

Fig. 10: Apartment gateway

— 12 —

ABB Welcome ®

4.2.4 Additional power supply mode

Fig. 11: Additional power supply mode

No. Functions

1 1->OFF, 2->ON, 3->ON

Enable an additional power source for systems with a system controller.

ON

1 2 3

1

Fig. 12: Additional power supply mode

Using gateway

+ system controller as auxiliary power supply to connect to other indoor stations in the same building when one system controller can’t cover all consumer units .

— 13 —

ABB Welcome ®

Wiring diagram:

Fig. 13: Additional power supply mode

— 14 —

ABB Welcome ®

4.2.5 Line amplifier

ON

1 2 3

1

Fig. 14: Line amplifier

No. Functions

1 1->ON, 2->OFF, 3->OFF

Strengthen the video signal and extend transmission. For increased distance, please refer to the ABB Welcome system manual.

Fig. 15: Line amplifier

Wiring diagram:

Fig. 16: Line amplifier

— 15 —

ABB Welcome ®

5 Technical data

Designation

Operating temperature

Protection

Single-wire clamps

Fine-wire clamps

Bus voltage

Value

-13 °F to +131 °F

IP 20

2 x 22 AWG - 2 x 18 AWG

2 x 22 AWG - 2 x 18 AWG

20 V - 30 V

— 16 —

ABB Welcome ®

6 Mounting and installation

Warning

Electric voltage!

Direct or indirect contact with live components can cause dangerous currents to flow through the body, which may result in electric shock, burns or even death.

Always disconnect the main power supply prior to installation and/or disassembly.

Work on the 110 V - 240 V supply system must be performed only by qualified personnel.

Requirements for the electrician 6.1

Warning

Electric voltage!

Install the device only if you have the necessary qualifications.

Incorrect installation endangers your life and that of the user of the electrical system.

Incorrect installation can cause serious damage to property, e.g., due to fire.

The minimum necessary expert knowledge and requirements for the installation are as follows:

Apply the "five safety rules" (DIN VDE 0105, EN 50110):

1. Disconnect from power.

2.

3.

4.

Secure against being re-connected.

Ensure there is no voltage.

Connect to earth.

5. Cover or barricade adjacent live parts.

Wear suitable personal protective clothing.

Use only suitable tools and measuring devices.

Check the type of supply network (TN system, IT system, TT system) to secure the following power supply conditions (classic connection to ground, protective earthing, necessary additional

6.2 measures, etc.).

General installation instructions

Terminate all branches of the wiring system via a connected bus device (e.g., indoor station, outdoor station, system device).

Do not install the system controller directly next to the bell transformer or other power supplies (to avoid interference).

Do not install the wires of the system bus together with 100 V - 240 V wires.

Do not use common cables for the connecting wires of the door openers and wires of the system bus.

Avoid bridges between different cable types.

Use only two wires for the system bus in a four-core or multi-core cable.

When looping, never install the incoming and outgoing bus inside the same cable.

Never install the internal and external bus inside the same cable.

— 17 —

ABB Welcome ®

6.3 Mounting

The device M2302 must only be installed on mounting rails according to DIN EN 500022.

— 18 —

ABB Inc.

Electrification Products

860 Ridge Lake Blvd.

Memphis, TN 38120 www.abb.com/door-entry-system-us [email protected]

Customer Service: 800-816-7809

7:00 a.m. - 5:30 p.m., CST, Monday-Friday [email protected]

Technical Support: 888-385-1221, Option 1

7:00 a.m. - 5:00 p.m., CST, Monday-Friday [email protected]

We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders and/or contracts, the agreed particulars shall prevail. ABB Inc. does not accept any responsibility whatsoever for potential errors or possible lack of information in this document.

We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents - in whole or in parts - is forbidden without prior written consent of ABB Inc.

© Copyright 2018 ABB. All rights reserved.