Graco 3A5538G, Reactor Connect for Reactor 2 Electric, Hydraulic, and Integrated Systems Instructions


Add to my manuals
22 Pages

advertisement

Graco 3A5538G, Reactor Connect for Reactor 2 Electric, Hydraulic, and Integrated Systems Instructions | Manualzz

Instructions

Reactor

®

Connect

For Reactor 2 Electric, Hydraulic, and Integrated Systems

3A5538G

EN

For remotely changing system settings on Graco Reactor 2 E-30, E-XP2, E-30i, E-XP2i,

H-30, H-40, H-50, H-XP2, and H-XP3 systems. For professional use only.

Important Safety Instructions

Read all warnings and instructions in this manual and in the Reactor ® 2 manual. Save all instructions.

IMPORTANT

By operating your Reactor 2 system with the cellular module installed, you are accepting the Graco Reactor

Connect Terms and Conditions and Software License

Agreement (“Terms”).

To review the Terms, install the Reactor Connect on your mobile device or visit www.graco.com.

2

Contents

Related Manuals. . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Models. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Agency Approvals. . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Typical Installation . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Electric Systems (Cellular Module Factory Kit) . . 5

Hydraulic Systems (Cellular Module

Factory Kit) . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Electric and Hydraulic Systems (Cellular Module

Retrofit Kit). . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Integrated Systems . . . . . . . . . . . . . . . . . . . . . . . 8

Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Mount Cellular Module on Electric and Hydraulic

Systems (Cellular Module Factory Kit) . . . . . 9

Mount Cellular Module on Electric and Hydraulic

Systems (Cellular Module Retrofit Kit). . . . . 10

Mount Cellular Module on Integrated

Systems. . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Update ADM Software. . . . . . . . . . . . . . . . . . . . 11

Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

Connect App to Reactor . . . . . . . . . . . . . . . . . . 13

Related Manuals

Manual in

English Description

333023 Reactor 2 E-30 and E-XP2 Proportioning Systems (Operation)

333024 Reactor 2 E-30 and E-XP2 Proportioning Systems (Repair-Parts)

334945 Reactor 2 Hydraulic Proportioning Systems (Operation)

334946 Reactor 2 Hydraulic Proportioning Systems (Repair-Parts)

3A1705 Reactor 2 E-30i and E-XP2i Proportioning Systems (Operation)

3A1706 Reactor 2 E-30i and E-XP2i Proportioning Systems (Repair-Parts)

332636 Reactor 2 Elite Integrated Proportioning Systems (Operation)

332637 Reactor 2 Elite Integrated Proportioning Systems (Repair-Parts)

3A5459 External Use Antenna (Kit)

Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

Reactor Connect . . . . . . . . . . . . . . . . . . . . . . . . 14

Cellular Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

View Cellular Screen. . . . . . . . . . . . . . . . . . . . . . 15

Reset Reactor Key . . . . . . . . . . . . . . . . . . . . . . . 15

Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

Disconnect Cellular Module . . . . . . . . . . . . . . . . 16

Parts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

Kits 25F088, 25F085, 25P159, 25M777

Electric and Hydraulic Systems Cellular

Module Factory Kits. . . . . . . . . . . . . . . . . . . 17

Kits 25F087, 25F084, 25E656, 25D612

Electric and Hydraulic Systems Cellular

Module Retrofit Kit. . . . . . . . . . . . . . . . . . . . 18

Kits 25F090, 25F091, 25E657, 25D614

Integrated Systems Cellular Module

Retrofit Kit . . . . . . . . . . . . . . . . . . . . . . . . . . 19

Technical Specifications . . . . . . . . . . . . . . . . . . . . 20

California Proposition 65 . . . . . . . . . . . . . . . . . . . . 21

Graco Standard Warranty. . . . . . . . . . . . . . . . . . . . 22

Graco Information. . . . . . . . . . . . . . . . . . . . . . . . . . 22

3A5538G

Models

Models

IMPORTANT

Always reference the latest available coverage information published at help.graco.com

.

Cellular

Module

Number † System

25N373

25F050

25N372

25M720

Reactor 2

Integrated Reactor 2

Reactor 2

Integrated Reactor 2

Reactor 2

Integrated Reactor 2

Reactor 2

Integrated Reactor 2

Cellular Module

Repair Kit

Number ‡

25F089

25F086

25E658

24M833

Cellular Module

Retrofit Kit

Number

25F087

25F090

25F084

25F091

25E656

25E657

25D612

25D614

Cellular Module

Factory Kit

Number

25F088

25F085

25P159

25M777

25M778 ✚

Cellular

Technology

CAT-M (4G)

CAT-M (4G)

CAT-1 LTE (4G)

3G HSPA/GSM

† Part number marked on cellular module label. Not for sale.

‡ Kit containing a replacement cellular module. The kit does not contain additional hardware or cables.

❖ Cellular module kit for installation on an existing proportioner without a cellular module.

★ Cellular module kit shipped with a new proportioner or package.

✚ Obsolete product listed for reference only. Not for sale.

Accessories

Part Description

25D878 KIT, antenna, external use

Agency Approvals

NOTE: Cellular module kit 25M833 contains Part 25M720. Cellular module kit 25E658 contains Part 25N372.

Cellular module kit 25F089 contains part 25N373. Cellular module kit 25F086 contains part 25F050.

Part

Number Description

25M720 MODULE, R2, 3G, ROW

25F050 MODULE, R2, CATM, ROW

25N372

25N373

MODULE, R2, CAT1, NA

MODULE, R2, CATM, NA

Approvals

3A5538G 3

4

Warnings

Warnings

The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclamation point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks.

When these symbols appear in the body of this manual or on warning labels, refer back to these Warnings.

Product-specific hazard symbols and warnings not covered in this section may appear throughout the body of this manual where applicable.

WARNING

ELECTRIC SHOCK HAZARD

This equipment must be grounded. Improper grounding, setup, or usage of the system can cause electric shock.

• Turn off and disconnect power at main switch before disconnecting any cables and before servicing or installing equipment.

• Connect only to grounded power source.

• All electrical wiring must be done by a qualified electrician and comply with all local codes and regulations.

EQUIPMENT MISUSE HAZARD

Misuse can cause death or serious injury.

• Do not operate the unit when fatigued or under the influence of drugs or alcohol.

• Do not exceed the maximum working pressure or temperature rating of the lowest rated system

component. See Technical Specifications

in all equipment manuals.

• Use fluids and solvents that are compatible with equipment wetted parts. See

Technical

Specifications in all equipment manuals. Read fluid and solvent manufacturer’s warnings. For

complete information about your material, request Safety Data Sheets (SDSs) from distributor or retailer.

• Do not leave the work area while equipment is energized or under pressure.

• Turn off all equipment and follow the Pressure Relief Procedure when equipment is not in use.

• Check equipment daily. Repair or replace worn or damaged parts immediately with genuine manufacturer’s replacement parts only.

• Do not alter or modify equipment. Alterations or modifications may void agency approvals and create safety hazards.

• Make sure all equipment is rated and approved for the environment in which you are using it.

• Use equipment only for its intended purpose. Call your distributor for information.

• Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.

• Do not kink or over bend hoses or use hoses to pull equipment.

• Keep children and animals away from work area.

• Comply with all applicable safety regulations.

MOVING PARTS HAZARD

Moving parts can pinch, cut or amputate fingers and other body parts.

• Keep clear of moving parts.

• Do not operate equipment with protective guards or covers removed.

• Pressurized equipment can start without warning. Before checking, moving, or servicing equipment, follow the Pressure Relief Procedure and disconnect all power sources.

3A5538G

Typical Installation

Electric Systems (Cellular Module Factory Kit)

C

F

D

A

E

MCM

B

Typical Installation

WLD

F IG . 1: Typical Reactor Connect Cell Module Installation (Reactor 2 Electric)

Ref.

A

B

C

D*

Description

Cellular Module

Antenna Cable

Antenna

Power Supply Cable

*

Ref.

E*

F

Description

Antenna Bulkhead

CAN Cable

MCM* Motor Control Module

Included with Reactor 2 proportioner.

3A5538G 5

Typical Installation

Hydraulic Systems (Cellular Module Factory Kit)

) ' $

&

(

%

+&0

WLD

F IG . 2: Typical Reactor Connect Cell Module Installation (Reactor 2 Hydraulic)

Ref.

A

B

C

D*

Description

Cellular Module

Antenna Cable

Antenna

Power Supply Cable

*

Ref.

E*

F

Description

Antenna Bulkhead

CAN Cable

HCM* Hydraulic Control Module

Included with Reactor 2 proportioner.

6 3A5538G

Typical Installation

Electric and Hydraulic Systems (Cellular Module Retrofit Kit)

C

CA

FC

AB

A

ADM

CB

CC

FT

WLD

F IG . 3 Typical Reactor Connect Cell Module Retrofit Installation (Reactor 2 Electric and Hydraulic)

Ref.

A

AB Cellular Module Nuts

ADM* Advanced Display Module

C

CA

CB*

Description

Cellular Module

Antenna

Bracket

Bracket Screws

*

Ref.

FC

FT*

CC

Description

Cellular Module CAN Cable

TCM CAN Cable

CAN Cable Tee

Included with Reactor 2 proportioner.

3A5538G 7

Typical Installation

Integrated Systems

$'0

:/

'

)

$3

&

$$

'

$

WLD

F IG . 4: Typical Reactor Connect Cell Module Installation (Integrated Reactor 2)

Ref.

A

AA

ADM* Advanced Display Module

C

D*

Description

Cellular Module

Mounting Screws

Antenna

Power Supply Cable

*

Ref.

F

AP

WL

Description

CAN Cable

Air Panel Cover (Compatible with Cellular

Module)

Warning Label

Included with Reactor 2 proportioner.

8 3A5538G

Overview

Overview Installation

Mount Cellular Module on

Electric and Hydraulic Systems

(Cellular Module Factory Kit)

To avoid injury due to unexpected machine operation initiated by remote controller, disconnect the cellular module from the system prior to troubleshooting. See

Disconnect Cellular Module , page 16.

The Reactor Connect allows the Graco Reactor 2 to be monitored and operated remotely. The Reactor 2 is intended to be controlled by an on-site operator. In any lock-out, tag-out procedure, take into consideration the potential for changes to the Reactor 2 settings due to remote operation.

NOTE:

Refer to F IG

. 1, page 5, F IG . 2, page 6, and

Parts , page 17.

1. Shut down the system. See your Reactor 2 operation manual for shutdown instructions.

2. Disconnect incoming power at the source.

3. Open the top and bottom door latches to the electrical cabinet.

4. Open the electrical cabinet.

5. Install the cellular module (A) at the top of the electrical enclosure using screws (107) and nuts

(105).

6. Attach the antenna cable (B) to the cellular module

(A) and the antenna bulkhead (E). Tighten by hand.

7. Remove the power supply cable (D) from the motor or hydraulic control module (MCM or HCM). Attach the cable to the cellular module.

8. Attach the CAN cable (F) to the cellular module (A) and the motor or hydraulic control module (MCM or

HCM).

9. Close and lock the electrical cabinet door with the door latches.

10. Install the antenna (C) onto the antenna bulkhead

(E) on top of the electrical cabinet. Tighten by hand.

3A5538G 9

Installation

Mount Cellular Module on

Electric and Hydraulic Systems

(Cellular Module Retrofit Kit)

NOTE:

Refer to F IG . 3, page 7.

1. Shut down the system. See your Reactor operation manual for shutdown instructions.

2. Disconnect incoming power at the source.

3. Open the top and bottom door latches to the electrical cabinet.

4. Open the electrical cabinet.

5. Inside the electrical cabinet, remove the TCM CAN cable from the TCM. Install the CAN cable tee (CC).

6. Install the TCM CAN cable (FT) and the cellular module CAN cable (FC) onto the cable tee (CC).

7. Using a Phillips screwdriver, loosen the four ADM mounting screws (MS) in the inside of the cabinet door.

SB

MS ti32875a

F IG . 5

8. Lift up the ADM and pull it away from the Reactor to unseat the mounting screws. For easy reassembly, leave the loosened screws attached to the ADM.

9. Gently lower the ADM until it is hanging from the

TCM CAN cable (FT). This exposes four shroud bolts (SB). See F IG . 5.

10

10. Remove the four bolts (SB) attaching the shroud to the Reactor frame. The door latches will hold the plastic shroud in place.

11. Slide the unattached end of the cellular module

CAN cable (FC) through the grommet in the electrical cabinet door.

12. Gently pull back the bottom inside corner of the shroud to access the unattached end of the cellular

CAN cable.

13. Slide the CAN cable to the top inside corner of the electrical cabinet door.

NOTE: To minimize cable strain during door operation, locate the CAN cable as close to the corner of the electrical cabinet door as possible.

14. Remove the two screws (CB) on the left side of the

Reactor electrical cabinet.

NOTE: For units with Graco InSite, remove both the mounting screws and the InSite module. Set aside.

15. Place the cellular module mounting bracket (CA) over the exposed electrical cabinet holes. Reinstall the screws (CB).

NOTE: For units with Graco InSite, reinstall the InSite module over the same holes but on top of the cellular module mounting bracket.

16. Install the antenna (C) onto the cellular module (A).

Tighten by hand.

17. Install the cellular module (A) onto the mounting bracket (CA) weld studs. Fully tighten the nuts (AB).

18. Connect the unattached end of the cellular module

CAN cable (FC) to the cellular module (A).

NOTE: Leave enough slack in the cable so that the door swings freely. Check both ends of the cable for slack so the cable is not stressed during door operation

19. Reinstall the shroud bolts (SB).

20. During first use, complete

Update ADM Software , page 11.

21. Remount the ADM using the four ADM mounting screws (MS). Tighten the screws fully.

22. Close the cabinet door and tighten the door latches.

3A5538G

Installation

Mount Cellular Module on

Integrated Systems

8. Attach the antenna (C) to the cellular module.

Tighten by hand.

9. During first use, complete

Update ADM Software

,

page 11.

Update ADM Software

NOTE:

Refer to F IG . 4, page 8.

1. Shut down system. See your Reactor 2 operation manual for shutdown instructions.

2. Disconnect incoming power at source.

3. Remove the original air panel cover. Install the cellular module-compatible air panel cover (AP).

NOTE: For units with Graco InSite, remove both the mounting screws and the InSite module from the existing air panel cover. Set aside.

4. Install the warning label (WL) on the back of the

new air panel cover (AP) as shown in F IG . 4.

5. Install the cellular module (A) onto the back of the new air panel cover using the predrilled holes and two mounting screws (AA).

NOTE: For units with Graco InSite, reinstall the InSite module onto the back of the new air panel cover using the remaining predrilled holes and InSite mounting screws.

6. Disconnect the power supply cable (D) from the

ADM. Connect the loose end of the power supply cable to the cellular module (A).

7. Connect the cellular module CAN cable (F) to the cellular module and the ADM. Tighten by hand.

1. Shut down system. See your Reactor operation manual for shutdown instructions.

2. For Electric and Hydraulic System Cellular

Module Retrofit Kits: a. Open the top and bottom door latches to the electrical cabinet.

b. Open the electrical cabinet. Using a Phillips screwdriver, loosen the four ADM mounting screws in the inside of the cabinet door.

c. Lift up the ADM and pull it away from the

Reactor to unseat the mounting screws. For easy reassembly, leave the loosened screws attached to the ADM.

d. Remove the token access panel on the back of the ADM.

e. Insert and press the software upgrade token firmly into the slot.

NOTE: There is no preferred orientation of the token.

3A5538G 11

Installation

3. For Integrated Systems: a. Loosen the set screw on the ADM mounting bracket. Remove the ADM from the bracket.

b. Loosen the set screw on the ADM mounting bracket. Remove the ADM from the bracket.

c. Remove the token access panel on the back of the ADM.

d. Insert and press the software upgrade token firmly into the slot.

NOTE: There is no preferred orientation of the token.

4. Turn on the system power.

NOTICE

A status is shown while software is updating to indicate progress. To prevent corrupting the software load, do not remove the token until the status screen disappears.

NOTE: When the ADM display turns on, you may see the following screens:

First:

Software is checking which modules will take the available updates.

Second:

Status of the update with approximate time until completion.

Third:

Updates are complete.

Icon indicates update success/failure. See the following table.

Icon Description

Update successful.

Update unsuccessful.

Update complete, no changes neces sary.

Modules were updated or didn’t require an update; however, one or more mod ules need to be updated manually with a token.

5. Remove the software update token.

6. Replace the token access panel.

7. Remount the ADM. Tighten the set screw fully.

8. Press to continue to the operation screen.

12 3A5538G

Setup

Download the Graco Reactor Connect on the Apple

App Store ® or the Android Google Play ™ store.

1. Open the Reactor Connect on your smartphone.

2. Read and accept the Terms of Use and data usage notification.

3. Review the app tutorial.

Connect App to Reactor

1. On the Reactor ADM, press setup mode.

to enter the

2. Press

7).

to go to the Cellular screen (see F IG .

NOTE: Before connecting the Reactor to an app for the first time,

Reset Reactor Key . See page 15.

3. To connect the app to the Reactor, scan the code.

a. Select the Scan code button on the app. (See

F IG . 6.) b. Using the app and your smartphone camera, scan the code displayed on the ADM Cellular screen.

4. If you have trouble scanning the code, type in the

IMEI and the key instead.

a. Select Type in IMEI and key. (See F IG . 6.) b. Enter the Reactor IMEI found on the ADM

Cellular screen.

c. Enter the Reactor key found on the ADM

Cellular screen.

d. Select the Connect button on the app.

F IG . 6: Connect Screen in App

Setup

3A5538G 13

Operation

Operation

Reactor Connect

H

G

J

K

L

M

N

P

R

S

T

W

Y

P

R

M

N

K

L

H

J

Ref. Description

G Reactor Status

Reactor Name

Menu

Reactor Power Switch

Heat Zone Settings

Heat Zone On/Off

Heat Zone Actual Temperature

Heat Zone Temperature Setpoint

Proportioner Start/Stop Switch

14

U

Ref. Description

S

T

U* Pump Pressure Setpoint

V

W

Y

V

Proportioner Mode (Spray, Jog, Park)

Pump Pressure

Material Usage

Cycle Count

Reset Cycle Count

* Not available with Reactor 2 Hydraulic systems.

3A5538G

Cellular Screen

Cellular Screen

F IG . 7: ADM Cellular Screen

Use this screen to connect the Reactor Connect to the

Reactor, determine the cellular signal strength, or reset the Reactor Key.

View Cellular Screen

1. On the Reactor ADM, press setup mode.

2. Press

to enter the

to go to the Cellular screen.

Reset Reactor Key

Resetting your Reactor Key prevents other users from remotely changing or viewing Reactor settings without first reconnecting to the Reactor.

1. On the Reactor ADM Cellular screen, press to reset the Reactor key.

2. Press to confirm resetting the Reactor key.

3. Reconnect your app to the Reactor. See

Connect

App to Reactor , page 13.

NOTE: After resetting your Reactor key, all operators using the Graco Reactor Connect must reconnect to the Reactor.

NOTE: For security of wireless control, change the

Reactor key on a regular basis and whenever there is a concern about unauthorized access.

3A5538G 15

Troubleshooting

Troubleshooting

For information on troubleshooting a Reactor, refer to the Reactor repair manual.

Disconnect Cellular Module

NOTE: Before troubleshooting the Reactor, disconnect the cellular module (A) from the ADM. The Reactor

Connect cannot change Reactor 2 settings while the cellular module is disconnected.

1. Shut down system. See your Reactor 2 operation manual for shutdown instructions.

2. Disconnect incoming power at the source.

3. For Electric and Hydraulic System Cellular

Module Factory Kits a. Open the electrical cabinet.

b. Disconnect the CAN cable (F) from the cellular module (A) and the motor or hydraulic control module (MCM or HCM).

c. Disconnect the power supply cable (D) from the cellular module. Connect the loose end of the power supply cable (D) to the motor or hydraulic control module (MCM or HCM).

d. Close and lock the electrical cabinet door with the door latches.

4. For Electric and Hydraulic System Cellular

Module Retrofit Kits: a. Open the top and bottom door latches to the electrical cabinet.

b. Disconnect the cellular module CAN cable (FC) from the cellular module (A).

5. For Integrated Systems: a. Disconnect the CAN cable (F) from the ADM.

b. Disconnect the power supply cable (D) from the cellular module (A) and connect the power supply cable to the ADM.

No module status LEDs are illuminated.

Problem

No network connection.

Network is connected, but there is no server connection.

Cause Solution

No power to cellular module.

Turn Reactor proportioner on.

Ensure cellular module is properly

installed. See Installation , page 9.

Still establishing cellular connection. Wait a few minutes for the unit to establish a connection.

Unable to establish cellular connection.

To establish cellular connection, move system to a location with cellular service.

Cellular module software is incorrect. Go to ADM Advanced Software screen and confirm that software is correct. If it is not, update the ADM software.

Server is not responding.

Mount accessory antenna 25D878 on the outside of your trailer.

Wait a few minutes for the unit to establish a connection.

16 3A5538G

Parts

Kits 25F088, 25F085, 25P159, 25M777

Electric and Hydraulic Systems Cellular Module Factory Kits

Parts

WLD

Ref. Part Description

101 25M833 KIT, MODULE, R2, 3G, ROW

25E658 KIT, MODULE, R2, CAT1, NA

25F089 KIT, MODULE, R2, CATM, NA

25F086 KIT, MODULE, R2, CATM, ROW

Qty.

1

1

1

1

Ref. Part Description

102 25M830 CABLE, antenna

104 25M828 ANTENNA, paddle

105 127158 NUT, 8-32

106 123422 CABLE, can

107 16X129 SCREW, phillips, 8-32, 3/2 long

Qty.

1

1

2

1

2

3A5538G 17

Parts

Kits 25F087, 25F084, 25E656, 25D612

Electric and Hydraulic Systems Cellular Module Retrofit Kit

Ref. Part Description

201 25M831 BRACKET

202 25M833 KIT, MODULE, R2, 3G, ROW

25E658 KIT, MODULE, R2, CAT1, NA

25F089 KIT, MODULE, R2, CATM, NA

25F086 KIT, MODULE, R2, CATM, ROW

203 25M828 ANTENNA, paddle

Qty.

1

1

1

1

1

1

WLD

Ref. Part Description

204 127158 NUT, 8-32

205 121002 CABLE, can

206 124654 TEE, CAN

207 25M832 TAG, agreement (not shown)

208 17E206 TOKEN, Reactor 2

Electric/Hydraulic (not shown)

Qty.

2

1

1

1

1

18 3A5538G

Kits 25F090, 25F091, 25E657, 25D614

Integrated Systems Cellular Module Retrofit Kit

Parts

WLD

Ref. Part Description

301 16H880 COVER, air panel

302 25M833 KIT, MODULE, R2, 3G, ROW

25E658 KIT, MODULE, R2, CAT1, NA

25F089 KIT, MODULE, R2, CATM, NA

25F086 KIT, MODULE, R2, CATM, ROW

303 25M828 ANTENNA, paddle

304 16X129 SCREW, phillips, 8-32, 3/8 long

Qty.

1

1

1

1

2

1

1

Ref. Part Description

305 121002 CABLE, CAN

307 ▲ 196548 LABEL, caution

308 125871 TIE, cable (not shown)

309 25M832 TAG, agreement (not shown)

310 17E206 TOKEN, GCA (not shown)

▲ Replacement safety labels, tags, and cards are available at no cost.

Qty.

1

1

4

1

1

3A5538G 19

Technical Specifications

Technical Specifications

Cellular Module (25M720)

FCC/IC

Contains FCC ID

Contains IC ID (Industry Canada)

XPY1CGM5NNN

8595A-1CGM5NNN

The enclosed device complies with Part 15 of the FCC Rules and with Industry Canada license-exempt

RSS standard(s). Operation is subject to the following two conditions:(1) this device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation.

Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

Cellular Radio Data

Cellular Radio

Band Support u-blox SARA-U201

Band 19 (800 MHz)

Band 5 (850 MHz)

Band 8 (900 MHz)

WCDMA/HSDPA/HSUPA Power Class

Band 2 (1900 MHz)

Band 1 (2100 MHz)

Power Class 3 (24 dBm) for WCDMA/HSDPA/HSUPA mode

Cellular Module (25N372)

FCC/IC

Contains FCC ID

Contains IC ID (Industry Canada)

MCQ-XB3C1

RI7XE866A1NA

1846A-XB3C1

5131A-XE866A1NA

The enclosed device complies with Part 15 of the FCC Rules and with Industry Canada license-exempt

RSS standard(s). Operation is subject to the following two conditions:(1) this device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation.

Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

Cellular Radio Data

Cellular Radio

Band Support

Telit LE866

Band 12 (700 MHz)

Band 4 (1700 MHz)

Band 2 (1900 MHz)

20 3A5538G

Technical Specifications

Cellular Module (25N373 and 25F050)

FCC/IC

Contains FCC ID

Contains IC ID (Industry Canada)

XPY2AGQN4NNN

8595A-2AGQN4NNN

The enclosed device complies with Part 15 of the FCC Rules and with Industry Canada license-exempt

RSS standard(s). Operation is subject to the following two conditions:(1) this device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation.

Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

Cellular Radio Data

Cellular Radio u-blox SARA-R410M-02B

Band 12 (700 MHz)

Band 28 (700 MHz)

Band 13 (700 MHz)

Band Support

Power Class

Band 20 (800 MHz)

Band 26 (850 MHz)

Band 18 (850 MHz)

Band 5 (850 MHz)

Band 19 (850 MHz)

Band 8 (900 MHz)

Band 4 (1700 MHz)

Band 3 (1800 MHz)

Band 2 (1900 MHz)

Band 25 (1900 MHz)

Band 1 (2100 MHz)

Band 39 (1900 MHz)

Up to 23 dBm, Power Class 3

California Proposition 65

CALIFORNIA RESIDENTS

WARNING: Cancer and reproductive harm – www.P65warnings.ca.gov.

3A5538G 21

Graco Standard Warranty

Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by

Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations.

This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.

This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.

THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT

LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE .

Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy

(including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.

GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A

PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT

MANUFACTURED BY GRACO . These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.

In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.

FOR GRACO CANADA CUSTOMERS

The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés,

à la suite de ou en rapport, directement ou indirectement, avec les procédures concernées.

Graco Information

For the latest information about Graco products, visit www.graco.com

.

For patent information, see www.graco.com/patents .

TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor.

Phone: 612-623-6921 or Toll Free: 1-800-328-0211 Fax: 612-378-3505

All written and visual data contained in this document reflects the latest product information available at the time of publication.

Graco reserves the right to make changes at any time without notice.

Original instructions. This manual contains English. MM 3A5538

Graco Headquarters: Minneapolis

International Offices: Belgium, China, Japan, Korea

GRACO INC. AND SUBSIDIARIES • P.O. BOX 1441 • MINNEAPOLIS MN 55440-1441 • USA

Copyright 2021, Graco Inc. All Graco manufacturing locations are registered to ISO 9001.

www.graco.com

Revision G , July 2021

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals