Graco 3A8242A, Wind Energy G3 Automatic Lubrication Pump Instructions

Add to my manuals
26 Pages

advertisement

Graco 3A8242A, Wind Energy G3 Automatic Lubrication Pump Instructions | Manualzz

Instructions

Wind Energy

G3 Automatic

Lubrication Pump

For dispensing of NLGI Grades #000 to #2 greases. For professional use only.

Not approved for use in explosive atmospheres or hazardous locations.

5100 psi (35.1 MPa, 351.6 bar) Maximum Pump Output Pressure

5000 psi (34.4 MPa, 344.7 bar) Maximum Fill Inlet Pressure

Important Safety Instructions

Read all warnings and instructions in this manual before using the equipment. Save these instructions.

3A8242A

EN

2

Contents

Model Numbers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Component Identification . . . . . . . . . . . . . . . . . . . . 6

Typical Installation . . . . . . . . . . . . . . . . . . . . . . . . 7

Series Progressive Divider Valve ................... 7

Injector Installations........................................ 8

Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Choose an Installation Location . . . . . . . . . . . . . . 9

System Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Fuses.............................................................. 9

Recommendations for Using Pump in Harsh

Environments ........................................... 9

Wiring and Installation Diagrams . . . . . . . . . . . . 10

Power DIN DC - 15 foot. . . . . . . . . . . . . . . . 10

Low Level Outputs. . . . . . . . . . . . . . . . . . . . 10

Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Pressure Relief Procedure . . . . . . . . . . . . . . . . . 11

Connect to Auxiliary Fittings . . . . . . . . . . . . . . . 11

Pressure Relief Valves ................................. 11

Load Pump with Grease . . . . . . . . . . . . . . . . . . 12

Prime the Pump . . . . . . . . . . . . . . . . . . . . . . . . . 12

Pump Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

Low Level Output On Pump Base Option..... 14

Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

Cleaning the Reservoir . . . . . . . . . . . . . . . . . . . 16

Recycling and Disposal . . . . . . . . . . . . . . . . . . . . . 17

End of Product Life . . . . . . . . . . . . . . . . . . . . . . 17

Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

Parts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

12 Liter Model . . . . . . . . . . . . . . . . . . . . . . . . . . 20

Part No./Description . . . . . . . . . . . . . . . . . . . . . . 21

Fuses............................................................ 21

Pressure Relief Valves ................................. 22

Installation and Repair Kits........................... 22

Technical Specifications . . . . . . . . . . . . . . . . . . . . 23

California Proposition 65 . . . . . . . . . . . . . . . . . . . . 23

Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

Mounting Bracket Dimensions . . . . . . . . . . . . . . 25

Graco Standard Warranty . . . . . . . . . . . . . . . . . . . 26

3A8242A

Model Numbers

Model

25T986

25T988

Reservoir

Capacity

8 Liter

12 Liter

Follower

Plate

X

Non-controller

X

X

Power

Input

DIN

DIN

Voltage

24VDC

X

X

Low Level

X

X

3A8242A 3

4

Warnings

Warnings

The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclamation point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks.

When these symbols appear in the body of this manual or on warning labels, refer back to these Warnings.

Product-specific hazard symbols and warnings not covered in this section may appear throughout the body of this manual where applicable.

WARNING

SKIN INJECTION HAZARD

High-pressure fluid from dispensing device, hose leaks, or ruptured components will pierce skin. This may look like just a cut, but it is a serious injury that can result in amputation. Get immediate surgical treatment.

• Do not point dispensing device at anyone or at any part of the body.

• Do not put your hand over the fluid outlet.

• Do not stop or deflect leaks with your hand, body, glove, or rag.

• Follow the Pressure Relief Procedure when you stop dispensing and before cleaning, checking, or servicing equipment.

• Tighten all fluid connections before operating the equipment.

• Check hoses and couplings daily. Replace worn or damaged parts immediately.

PRESSURIZED EQUIPMENT HAZARD

Fluid from the equipment, leaks, or ruptured components can splash in the eyes or on skin and cause serious injury.

• Follow the Pressure Relief Procedure when you stop spraying/dispensing and before cleaning, checking, or servicing equipment.

• Tighten all fluid connections before operating the equipment.

• Check hoses, tubes, and couplings daily. Replace worn or damaged parts immediately.

3A8242A

3A8242A

Warnings

WARNING

EQUIPMENT MISUSE HAZARD

Misuse can cause death or serious injury.

• Do not operate the unit when fatigued or under the influence of drugs or alcohol.

• Do not exceed the maximum working pressure or temperature rating of the lowest rated system component. See Technical Specifications in all equipment manuals.

• Use fluids and solvents that are compatible with equipment wetted parts. See Technical

Specifications in all equipment manuals. Read fluid and solvent manufacturer’s warnings. For complete information about your material, request Safety Data Sheets (SDSs) from distributor or retailer.

• Turn off all equipment and follow the Pressure Relief Procedure when equipment is not in use.

• Check equipment daily. Repair or replace worn or damaged parts immediately with genuine manufacturer’s replacement parts only.

• Do not alter or modify equipment. Alterations or modifications may void agency approvals and create safety hazards.

• Make sure all equipment is rated and approved for the environment in which you are using it.

• Use equipment only for its intended purpose. Call your distributor for information.

• Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.

• Do not kink or over bend hoses or use hoses to pull equipment.

• Keep children and animals away from work area.

• Comply with all applicable safety regulations.

PLASTIC PARTS CLEANING SOLVENT HAZARD

Many cleaning solvents can degrade plastic parts and cause them to fail, which could cause serious injury or property damage.

• Use only compatible solvents to clean plastic structural or pressure-containing parts.

• See Technical Specifications in all equipment manuals for materials of construction. Consult the solvent manufacturer for information and recommendations about compatibility.

MOVING PARTS HAZARD

Moving parts can pinch, cut or amputate fingers and other body parts.

• Keep clear of moving parts.

• Do not operate equipment with protective guards or covers removed.

• Equipment can start without warning. Before checking, moving, or servicing equipment, follow the

Pressure Relief Procedure and disconnect all power sources.

PERSONAL PROTECTIVE EQUIPMENT

Wear appropriate protective equipment when in the work area to help prevent serious injury, including eye injury, hearing loss, inhalation of toxic fumes, and burns. Protective equipment includes but is not limited to:

• Protective eyewear, and hearing protection.

• Respirators, protective clothing, and gloves as recommended by the fluid and solvent manufacturer.

5

Component Identification

Component Identification

See

Notes , page 19 for expanded view.

G

O

L

G

A

L

A

H

E

N

D

J

F IG . 1

Key:

A Reservoir

B Pump Element (1 included. Can accommodate 3 total)

C Pressure Relief Valve (Not shown. Not included / required

for each outlet - Available from Graco. See Parts

, page

20.)

D Zerk Inlet Fill Fitting (1 included / grease models only)

E Pump Outlet Plug (2 included)

F Fuse (Not included, not shown. Available from Graco. See

Parts , page 20.)

G Cover

H Bottom Mounting Bracket

J Part Number

K Follower Plate

L Vent Hole for Follower Plate

M Low Level Connector

N Power Connector

O Low Level Connector

6

K

H

B

M

3A8242A

Typical Installation

Series Progressive Divider Valve

Component Identification

A

F IG . 2

Key

A Connected to fused power source

B Pressure relief valve (Not included; required for each outlet - user supplied)

C Supply Hose (user supplied)

D Series progressive divider valves

E To lube points

3A8242A

B

C

D

E

F

7

Component Identification

Injector Installations

H

B

C E

A

F IG . 3

Key

A Connected to fused power source

B Pressure relief valve (Not included; required for each outlet - user supplied)

C Supply Hose (user supplied)

D Injectors

E To lube points

G Vent valve (Not included / available from Graco)

H Return to reservoir

8

G D

F

3A8242A

Installation

Installation

Unpacking

NOTICE

To avoid damage, observe precautions for handling electrostatic sensitive devices. Touch ground before handling pump.

• Use designated mounting holes and provided configurations only.

System Wiring

The pump module was carefully packed for shipment by

Graco. When the package arrives, perform the following procedure to unpack the units:

1.

Inspect the shipping box carefully for shipping damage. Contact the carrier promptly if damage is discovered.

2.

Unseal the box and inspect the contents carefully.

There should not be any damaged parts.

3.

Compare the packing slip against all items included in the box. Any shortages or other inspection problems should be reported immediately.

Fuses

NOTICE

Fuses (user supplied) are required on all models. To avoid equipment damage:

• Never operate G3 Pump models without a fuse installed.

• A fuse of the correct voltage must be installed in line with the power entry to the system.

Fuse Kits are available from Graco. The following Table identifies the correct fuse to use for your input voltage and the corresponding Graco Kit number.

Choose an Installation Location

AUTOMATIC SYSTEM ACTIVATION HAZARD

If the system is equipped with has an automatic timer

(user supplied) that activates the pump lubrication system when power is connected or when exiting the programming function, unexpected activation of the system could result in serious injury, including skin injection and amputation.

Before you install or remove the lubrication pump from the system, disconnect and isolate all power supplies and relieve all pressure.

• Select a location that adequately supports the weight of the G3 Pump and lubricant, as well as all plumbing and electrical connections.

• Refer to the mounting hole layouts provided in

Mounting Bracket Dimensions , page 25. No other

installation configuration should be used.

Input Voltage

24 VDC

Fuse Value

4 A

Graco Kit No.

571040

Recommendations for Using Pump in

Harsh Environments

• If using a DIN style power or alarm harness with a right angle mating connector, make sure the connector does not exit the unit in the UP direction.

• Use a corrosion preventative electrical grease on all contacts.

3A8242A 9

Installation

Wiring and Installation Diagrams

The following table identifies the wiring and installation diagrams for the cable included with the pump.

Power DIN DC - 15 foot

4

Pin and Related Wire Color (F IG . 4)

Pin

1

2

3

Pin Name

-VDC

+VDC

Not Used

Not Used

Color

Black

White

Not Used

Green

Low Level Outputs

See Low Level Output Option, page 14 for functional

description. See

Technical Specifications , page 23 for

ratings.

Pins Output on Base (F IG . 5)

Pin

1

2

3

4

Pin Name

LL N.O.

Not Used

LL COM

Not Used

F IG . 5

Pins Output on Top Cover (F IG . 6)

Pin

3

4

1

2

Pin Name

LL COM

Not Used

LL N.C.

Not Used

F

IG

. 6

F IG . 4

10 3A8242A

Setup

Setup

Pressure Relief Procedure

Follow the Pressure Relief Procedure whenever you see this symbol.

Connect to Auxiliary Fittings

This equipment stays pressurized until pressure is manually relieved. To help prevent serious injury from pressurized fluid, such as skin injection, splashing fluid and moving parts, follow the Pressure Relief

Procedure when you stop dispensing and before cleaning, checking, or servicing the equipment.

Relieve pressure in system using two wrenches working in opposite directions on pump element and pump element fitting to slowly loosen fitting only until fitting is loose and no more lubricant or air is leaking from fitting.

NOTE: When loosening pump element fitting, do NOT loosen pump element . Loosening pump element will change the output volume.

NOTICE

Do not attach unsupported equipment to auxiliary fittings such as fill ports and pump element. Attaching unsupported equipment to these fitting can result in irreparable housing damage.

• Always use two wrenches working in opposite directions when connecting anything to pump element or auxiliary fittings. See F IG . 7 for an example.

• Torque pump element fittings to 50 in. lbs (5.6

N•m).

• When connecting pump element into housing torque to 50 in. lbs (5.6 N•m).

Pressure Relief Valves

To prevent over-pressurization, which can result in equipment rupture and serious injury, a pressure relief valve appropriate for the lubrication system must be installed close to every pump outlet to alleviate unintended pressure rises in the system and protect the G3 pump from damage.

• Only use a pressure relief valve that is rated for no more than the working pressure of any component installed in the system.

• Install a pressure relief valve close to every pump outlet; before any auxiliary fitting.

NOTE: A pressure relief valve can be purchased from

Graco.

F IG . 7

3A8242A 11

Setup

Load Pump with Grease

To ensure optimal performance from the G3:

• Only use NLGI #000 - #2 greases appropriate for your application, automatic dispensing, and the temperature. Consult with machine and lube manufacturer for details.

• The reservoir can be filled using a hand operated pump, pneumatic pump or electric transfer pump.

• Do not overfill.

• Do not operate G3 without reservoir attached.

NOTICE

• Always clean inlet fitting with a clean dry cloth prior to filling reservoir. Dirt and/or debris can damage pump and/or lubrication system.

• Care must be used when filling the reservoir using a pneumatic or electric transfer pump to not pressurize and break the reservoir.

1.

Connect fill hose to inlet fitting.

2.

For higher viscosity fluids, start pump to rotate stirring paddle during fill to prevent air pockets from

 forming in grease. Do not exceed 30 minutes run time.

For models using an external controller, start pump operation per your controller specifications.

3.

Fill reservoir with grease until seal of follower plate breaches the vent hole (F IG

. 8) and the majority of air is expelled from the reservoir.

NOTE: Vent port, located in rear of reservoir, should not be used as an overfill port/indicator.

4.

Remove fill hose.

Prime the Pump

NOTE: It is not necessary to prime pump every time pump is filled with lubricant.

Pump only requires priming the first time it is used or if it is allowed to run dry.

1.

Loosen pump element fitting (F

IG

. 9).

NOTE: When loosening pump element fitting, do NOT loosen pump element . Loosening pump element will change the output volume

F IG . 9

2.

Only run pump until air-free lubricant is dispensed out of element fitting (F

IG

. 10).

vent hole

F IG . 8

12 3A8242A

F

IG

. 10

Setup

3.

Tighten pump element fitting using two wrenches working in opposite directions (F

IG

. 9).

3A8242A 13

Pump Operation

Pump Operation

The G3 Pump can be controlled using an external, user supplied, power source and controller.

Refer to the

Typical Installation

diagrams starting on

page 7 for correct location of the required fuses.

NOTE:

• When using an external power source and controller, Pump ON (Run) Time should be set for no longer than 30 minutes.

• In most cases, Pump OFF (Rest) Time should be twice as long as Pump ON (Run) time. If alternative

ON / OFF times are required, contact Graco Customer Service for assistance.

Low Level Output On Pump Base Option

The G3 pumps without controllers include a Low Level

Output Option. The low level signal is monitored across

PINS 1 and 3. For PIN 1 and 3 locations and wiring

information the Low Level Outputs diagram, page 10.

NOTE: A low level warning is triggered when the controller detects PINS 1 and 3 have momentarily closed.

When the grease level has reached a low warning level,

PINS 1 and 3 momentarily close (1 time per paddle revolution) sending the signal that the fluid has reached a low level to the controller.

To ensure that a low level condition has been met, 3 or more low level triggers must be detected within 1 minute or less.

See F

IG

. 11 for an illustration of a typical Low Level Output response to low grease level.

Typical Low Level Output Response with Low Level Fluids (Output On Pump Base)

200 ms

Closed

Contact

Position

Open

3 s

F IG . 11

14 3A8242A

Typical Low-Level Output Response with Low-Level Fluid (Output On Top Cover)

Pump Operation

F IG . 12

3A8242A 15

Maintenance

Maintenance

Frequency

Daily and at refill Zerk Fittings

Component

Daily

Monthly

G3 Pump Unit and Reservoir

External Wiring Harness

Cleaning the Reservoir

Only use water or solvents compatible with polycarbonate to clean reservoir.

NOTICE

Most solvents will degrade the polycarbonate reservoir and cause it to fail.

Required Maintenance

Keep all fittings clean using a clean dry cloth. Dirt and/or debris can damage pump and/or lubrication system.

Keep pump unit and reservoir clean using a clean dry cloth.

Verify external harnesses are secure.

16 3A8242A

Recycling and Disposal

End of Product Life

At the end of the product’s useful life, dismantle and recycle it in a responsible manner.

• Perform the

Pressure Relief Procedure , page 11.

• Drain and dispose of fluids according to applicable regulations. Refer to the material manufacturer’s

Safety Data Sheet.

• Remove motors, circuit boards, LCDs (liquid crystal displays), and other electronic components. Recycle according to applicable regulations.

• Do not dispose of electronic components with household or commercial waste.

• Deliver remaining product to a recycling facility.

Recycling and Disposal

3A8242A 17

Troubleshooting

Troubleshooting

Problem

Unit does not power on

Unit does not power on

Cause Solution

Incorrect/loose wiring Refer to

Installation instructions, page 9.

Tripped external fuse due to internal component failure

Tripped external fuse due to pumping non-cold weather lubricant in cold weather -13°F (-25°C)

Contact Graco Customer Service.

Replace lubricant with pumpable lubricant, rated for environmental conditions and application.

Lubricant leaks past seal located on the bottom of the reservoir

Replace fuse.

Reservoir retaining tabs are cracked or broken

Reservoir is being pressurized during filling

Replace reservoir.

Ensure vent hole is not plugged.

If problem persists, contact Graco

Customer Service or your local

Graco distributor for assistance.

Failed motor Replace unit.

Unit not pumping during ON cycle, but controller lights and functions

Follower plate is not going down

Pump takes several minutes before it begins pumping at the highest pump volume setting (no stroke adjust spacers installed)

After wiring and installing equipment pump is not working

Air is trapped in the reservoir between the follower plate and lubricant

Pumping non-cold weather lubricant in cold weather -13°F (-25°C)

Pump wired backwards

Add grease following with Grease

Ensure air is purged.

Load Pump

instructions, page 12.

Add 1 stroke adjust spacer and adjust lube cycle time to accommodate the difference in pump volume per stroke.

Rewire pump. See Wiring and

Installation Diagrams , page 10.

18 3A8242A

Notes

Troubleshooting

3A8242A 19

Parts

Parts

12 Liter Model

2

42

32

20

21

10

24

27

1

25

43

45

4

30

23

16

12

20

44

22

3

26

33 34

41

5

40

42

29

3A8242A

Parts

Part No./Description

40

41

42

43

44

30

32

33

34

38

39

22

23

24

25

26

27

29

Ref.

10

12

16

20

21

1

2

3

4

5

Part Description

BASE, three pump housing

SCREW, cap, hex head

RING, snap (12L only)

COVER

17S695 SEAL, reservoir, 8L

SEAL, reservoir. 12L

RESERVOIR, 8L

RESERVOIR, 12L

SLEEVE, (12L only)

ROD, support

ROD, guide (12L only)

SPRING, compression (12L only)

(Install springs as shown in

Notes , page 19)

19B457 SEAL, grease (12L only)

Qty.

1

4

1

2

1

1

1

4

1

1

1

2

NUT (12L only)

PLATE, follower (12L only)

BEARING, sleeve (12L only)

PLATE, wiper arm

ADAPTER, base, reservoir

BRCKET, bottom

COVER, vent

SEAL, top, foam

1

1

1

1

1

1

1

SCREW, SHC, 10 x 0.62, sst

WASHER, flat

SPACER, pump shim (not shown)

PARTS, bracket mounting

(bagged)

2

2

1

1

2

1

SCREW, cap, hex head

NUT, jam, Ny-loc

WASHER, plain

LOW LEVEL, DIN (12L only)

RING, magnet (12L only)

45 571041 KIT, pump element

46 16U790 CABLE, DIN, bare

47  16A579 LABEL, safety

2

6

6

1

1

1

1

1

 Replacement safety labels, tags, and cards are available at no cost.

Fuses

Part Description

571040 FUSE, 24 volt DC

Qty

1

3A8242A 21

Parts

Pressure Relief Valves

Important Information regarding Pressure Relief

Valve 16C807.

 Pressure Relief Valve 16C807 can only be used on the G3 Pump.

It is not intended for use with any other products.

The pressure relief valve uses a pressure adjustment screw (a) to set the pressure release point. It is not intended as a way to relieve pressure during normal operation, but as a protective a b measure in the event there is an unintended pressure increase in the system. Do not use this pressure relief valve a means of relieving pressure in day-to-day, normal cycle operation. ti15644 a = adjustment screw

 b = locking nut

The pressure adjustment screw will require periodic adjustments.

Whenever the valve is set/adjusted (after the set point is found) it is important to ensure that the valve is not bottomed out and there is at least 1/2 turn of adjustment remaining. This is determined by turning the screw (a)

1/2 turn and then back turning it out again.

NOTE: Turning adjustment screw (a) clockwise increases pressure.

Part Description

16C807  VALVE, pressure relief, 500-3500 psi

(3.44 MPa, 34.4 bar - 24.1 MPa, 241 bar), Set pressure 3000 psi + 10%

(20.68 MPa, 206.8 bar + 10%)

Included in Kit 571028

563156 VALVE, pressure relief, 750 psi (5.17

MPa, 51.71 bar)

563157 VALVE, pressure relief, 1000 psi (6.89

MPa, 68.95 bar)

563158 VALVE, pressure relief, 1500 psi

(10.34 MPa, 103.42 bar)

563159 VALVE, pressure relief, 2000 psi

(13.78 MPa, 137.89 bar)

563160 VALVE, pressure relief, 2500 psi

(17.23 MPa, 172.36 bar)

563161 VALVE, pressure relief, 3000 psi

(20.68 MPa, 206.84 bar)

563190 VALVE, pressure relief, 5500 psi

(37.92 MPa, 379.21 bar)

Installation and Repair Kits

Qty

1

1

1

1

1

1

1

1

Manual

Number Kit No.

Description

571026 KIT, output union, 3 pump

571063 KIT, output union, 2 pump

571028 KIT, return to reservoir NPT, includes pressure relief valve

16C807

571071 KIT, return to reservoir BSPP, includes pressure relief valve

16C807

571058 KIT, output adapter, NPT

571070 KIT, output, adapter, BSPP

571060 KIT, fill, zerk, leakproof

25E455 KIT, repair, reservoir 8 liter

25E456 KIT, repair, reservoir, 12 liter

25E457 KIT, repair, reservoir 16 liter

25E458 KIT, repair, reservoir, 20 liter

25E485 KIT, mounting hardware

3A0523

3A0525

3A0522

NA

3A6385

NA

22 3A8242A

Technical Specifications

Technical Specifications

Wind Energy G3 Standard Automatic Lubrication Pump

Pump Output Pressure

Fill Inlet Pressure

Power

24 VDC

Outputs - Low Level (Dry Contact)

Contact Rating

Switch Rating

Switching Current

Carry Current

Fluid

Pumps

Pump Output

Pump Outlet

Weight

8 Liter Models

12 Liter Models

US

5100 psi

5000 psi

Metric

35.1 MPa, 351.6 bar

34.4 MPa, 344.7 bar

18 - 32 VDC; 2.5 A current, 60 W, inrush/locked rotor 6 A

10 Watts Maximum

200 VDC Maximum

0.5 A Maximum

1.2 A Maximum

Grease NLGI 000 - #2

Up to 3

0.25 in.

3

/ minute 4 cm

3

/ minute

1/4-18 NPSF. Mates with 1/4-18 NPT male fittings

18 lb.

26 lb.

8.20 kg

11.82 kg

California Proposition 65

CALIFORNIA RESIDENTS

WARNING: Cancer and reproductive harm – www.P65warnings.ca.gov.

3A8242A 23

Technical Specifications

Dimensions

Model

8L

12L

Inches

22.36

26.30

Height cm

56.79

66.80

Inches

8.94

8.94

Width cm

22.70

22.70

Inches

10.37

10.37

Depth cm

26.34

26.34

24 3A8242A

Mounting Bracket Dimensions

Technical Specifications

3A8242A 25

Graco Standard Warranty

Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by

Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations.

This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.

This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.

THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED

TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE .

Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy

(including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.

GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A

PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT

MANUFACTURED BY GRACO . These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.

In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.

FOR GRACO CANADA CUSTOMERS

The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite de ou en rapport, directement ou indirectement, avec les procédures concernées.

Graco Information

For the latest information about Graco products, visit www.graco.com

.

For patent information, see www.graco.com/patents .

TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor.

Phone: 612-623-6928 or Toll Free: 1-800-533-9655, Fax: 612-378-3590

All written and visual data contained in this document reflects the latest product information available at the time of publication.

Graco reserves the right to make changes at any time without notice.

Original instructions. This manual contains English. MM

Graco Headquarters: Minneapolis

International Offices: Belgium, China, Japan, Korea

GRACO INC. AND SUBSIDIARIES • P.O. BOX 1441 • MINNEAPOLIS MN 55440-1441 • USA

Copyright 2020, Graco Inc. All Graco manufacturing locations are registered to ISO 9001.

www.graco.com

Revision A, December 2020

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals