Graco 311606A, 15K012 Pneumatic VFD/BPR Control Kit Owner's Manual

Add to my manuals
2 Pages

advertisement

Graco 311606A, 15K012 Pneumatic VFD/BPR Control Kit Owner's Manual | Manualzz

Instructions

15K012 Pneumatic

VFD/BPR Control

311606A

For control of a pneumatic back pressure regulator, using a Graco Variable

Frequency Drive (VFD) and E-Flo

Plus Electric Circulation Pump.

Important Safety Instructions

Read all warnings and instructions in E-Flo Plus Operation

Manual 311593, Pneumatic Back Pressure Regulator Manual

311595, and VFD Manual 311596. Save these instructions.

See page 2 for Installation and Operation instructions.

Air Outlet to BPR

Off Production

Air Line On Production

Air Line

Solenoid

On Production

Air Regulator

Off Production

Air Regulator

Lead wires

Graco Inc. P.O. Box 1441 Minneapolis, MN 55440-1441

Copyright 2007, Graco Inc. is registered to I.S. EN ISO 9001

Air Inlet

Installation

0.135 in. (3.4 mm)

Do not install equipment approved only for non-hazardous locations in a hazardous area.

See the illustration on page 1. The 15K012 Kit is a preassembled module

which is not intended for use in a hazardous location. Install the kit in a non-hazardous area only. Mount the panel vertically to protect components from accumulation of air line contaminants and condensation. See the mounting hole detail.

Connect a 5/32 in. (4 mm) OD air supply line to the air inlet elbow. Plumb another 5/32 in. (4 mm) OD air line between the Outlet to BPR port and the back pressure regulator (BPR), which is located in the hazardous area.

Connect one lead wire to Pin 26 on the variable frequency drive (VFD).

Connect the other lead wire to Pin 21. See VFD manual 311596 for specific wiring details.

3.5 in. (89 mm)

4.0 in. (102 mm)

0.25 in.

(6.3 mm)

Operation

The kit supplies higher pressure air to the BPR for normal production conditions, or lower pressure air for off production times. The off production state reduces energy use, paint shear, and pump/system wear during down times.

The solenoid (0.50 W, 24 Vdc, .020 A) is actuated or deactuated by a 24 Vdc input/output signal from the VFD. When actuated, the solenoid supplies higher air pressure to the BPR to support production requirements. When the solenoid is not actuated, lower air pressure is supplied to the BPR, slowing down the system.

Technical Data

Maximum Air Working Pressure. . . . . . . . . . . . . . . . . . . . 120 psi (0.8 MPa, 8.4 bar)

Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Vdc

Air Porting Sizes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5/32 OD Tube (4 mm)

Cable Length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 ft (2 m)

Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.1 lb (0.95 kg)

Graco Information

TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor.

Phone: 612-623-6921 or Toll Free: 1-800-328-0211 Fax: 612-378-3505

All written and visual data contained in this document reflects the latest product information available at the time of publication.

Graco reserves the right to make changes at any time without notice.

MM 311606

Graco Headquarters: Minneapolis

International Offices: Belgium, China, Japan, Korea

GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440-1441 www.graco.com

Printed in USA 311606A

1/2007