Coram Showers OPTIMA Manual
Coram Showers Optima is a double sliding door and side panel enclosure designed to fit shower trays of various sizes. It features:
- Sliding doors for easy access and space-saving
- Side panel for additional privacy and to prevent water splashing
- Durable construction with toughened glass and aluminum frame
- Adjustable cam mechanism for smooth door operation
- Magnetic seals for a watertight closure
- Easy installation with pre-drilled holes and all necessary hardware included
- Modern and stylish design to complement any bathroom decor
Advertisement
Advertisement
00 71448 00 / Issue 3 / 12
OPTIMA DOUBLE SLIDING DOOR
/ SIDE PANEL
Sliding Door - Pages 2 - 8 Sliding Door & Side Panel - Pages 9 - 16
Please read these instructions carefully and keep for future reference.
Incorrect fitting will invalidate the guarantee.
SAFETY
● Handle glass with great care.
Although the glass is very tough, sharp impacts can damage both the glass and metal frame.
● Make sure there are no hidden pipes or cables hidden in the wall where you intend to drill.
● Wear safety goggles, shoes and appropriate clothing.
BEFORE INSTALLATION
● Check that the shower tray is level in all directions. The enclosure will not sit correctly on an uneven surface.
If uneven, the wall channels may not fit and the doors may not shut correctly.
● The enclosure should be fitted on tiled walls which are sealed with waterproof grout.
● There must be a good silicone seal between the rim of the shower tray and the wall.
● The shower tray and the enclosure must match in size. Attempting to fit the incorrect size of enclosure to
the shower tray will result in water leaks.
● Always check very carefully that components are vertical.
● To avoid damage, use the opened out packaging to build the enclosure on.
Equipment needed:
Drill, 6.5mm Masonry Bit, 4.5mm & 3mm Metal Bits (general), Crosshead Screwdriver, 16mm Spanner, Spirit Level, Pencil,
Tape Measure, Masking Tape, Silicone Sealant.
Note: The screws and wall plugs supplied are for masonry walls. For lightweight walls i.e. stud partition, plasterboard etc, use the correct type of fixings.
CUSTOMER CARELINE 01746 713410
2
Check contents of pack before installation. If anything is missing, contact our Customer Careline for assistance.
CUSTOMER CARELINE: 01746 713410
PN3230 PN80519
8 2
PN3225
32mm
PN60014
8
1500 =
PN40272
1700 =
PN40273
4
2
PN40260
13mm
PN3222
10
PN80564
2
10mm
PN4748
1
14
PN40259
PN50103
2
8
PN60250 4
PN4745
8
PN50382
4
PN60418
1 PN60058
1
1 a
100mm max
=
=
100mm max
=
ø 4.5
mm b
PN10801
1500 RAIL - PN80531
1700 RAIL - PN80532
1500 RAIL - PN80531
1700 RAIL - PN80532
PN10801 a: Drill holes in both wall channels at points shown using a 4.5mm drill bit, where shown. b: Ensure the shower tray is level in all directions. IMPORTANT: Clean the tray and seal the gap between the tray surface and tiles. It is important that the tray is sealed right up to the tray edge so that the bottom of the wall channel is sealed. Failure to do this will cause water to leak under the wall channel and between the tray and tiles, resulting in damp patches on the wall and under the tray.
2 a
X
X = Door widths
1500 = 1450 - 1500mm
1700 = 1650 - 1700mm b c
Inside
ø 6.5
mm
32mm
3 a: Place the wall channels on the tray ensuring they are vertical and an equal distance back from the front of the tray.
Place masking tape against the wall before marking drill hole positions, this will help prevent the drill bit slipping. Drill 6.5mm holes, 30mm deep and insert the wall plugs. b: Apply sealant to the back of the wall channels. c: Fix the wall channels to the walls using 8 x 32mm screws and screw caps.
a b
=
= a: Place the bottom rail onto the tray with its end mouldings inserted into the wall channels. b: Centre the bottom rail between the wall channels so that there is an equal gap at each end.
3
4
4 5
Outside face of fixed panel
Outside face of fixed panel
Outside face of fixed panels
Fixed panel bracket
6
Push fit the 'short flipper seals' onto the top and bottom edges of the fixed panels - flush against the metal profile.
Ensure the flipper seal 'flaps' are on the inside of the fixed panels.
Note: Wetting the glass with water will help to fit the seals.
Position the fixed panels into the wall channels and slide down so they fully slot onto the end mouldings of the bottom rail. Inside the enclosure, ensure the panels sit in the 'fixed panel brackets', slide the brackets along the rail and position under the panels as shown.
13mm
Inside
Position the top rail onto the top of the
'fixed panels'. Adjust the position of the fixed panel brackets as required.
Line up the holes and fix using 2 x 13mm screws.
7
ø 3 mm
From inside
10mm
8
Check the door frame is vertical and is centrally positioned between the wall channels.
From inside the enclosure, in the positions shown, drill through the wall channels into the fixed panels using a 3mm drill bit, do not drill too deep! Fix using 6 x 10mm screws and screw caps.
PN40260
Inside
PN4745
Fit 'flipper seals' (PN40260) onto the edge of the fixed panels. Ensure the flipper seal 'flaps' are on the inside.
Note: Wetting the glass with water will help fit the seals.
From inside the enclosure, tighten all 4 fixed panel bracket grub screws onto the glass using the allen key - do not overtighten . Fit the cover caps (PN4745) into the holes.
9 PN40259
PN80564
PN80564
Outside face of door
PN
40259
Outside face of door PN80564 Door handle hole
Door handle hole
Push fit 'flipper seals' (PN40259) onto the back edge of the doors.
Ensure the flipper seal 'flaps' are on the outside of the doors.
Push fit 'magnetic seals' (PN80564) onto the closing edge of the doors (the same side as door handle hole).
Note: Ensure the magnetic seals are positioned as shown.
Note: Wetting the glass with water will help fit the seals.
5
10
From inside
Top of doors
Bottom of doors
IMPORTANT: It is advised that this stage is carried out by two people to avoid damaging the runners, rails or doors.
From inside the enclosure, push fit the 'runners' fitted to the top and bottom of the doors, onto the 'door rollers' pre-fitted in the top and bottom rails.
11 a
From inside b c
PN50103
6
The 'cam adjusters' at the top and bottom of the doors may need adjusting so that the doors slide freely and the magnetic seals meet evenly when the doors are closed. a: Loosen all 4 cam adjuster screws on each door (1 turn maximum). b: Turn the cam adjusters (by hand or using a 16mm spanner) until the doors hang vertically. Re-tighten the screws - do not over tighten . c: Push fit all 8 covers onto the doors.
12
Fit the door handles to the doors ensuring the supplied handle washers are used on each side of the glass.
Chrome finish handle are supplied for all frame finish options.
13
14
PN60250
PN60058
Lubricate the inner top and bottom rails using the wipe provided.
PN60250
Push fit all 4 covers (PN60250) onto the middle door stops on the top and bottom rails.
15
Fit the Bump Stops to the rail, top and bottom as shown on the fixed panel side. Tighten the screw with a screw driver, do not over tighten. Place cover cap in the hole.
7
15
From the outside only , apply sealant to the bottom of the enclosure and 50mm up the wall channels and vertical joints as shown.
50mm
Recycling
Packaging :- The cardboard and polythene parts of this packaging can be recycled.
End of life :- This product contains materials such as aluminium and glass which can be recycled.
Please contact your local authority to find your nearest recycling centre.
IMPORTANT: You must not use the shower for 24 hours after installation of the enclosure.
DO NOT use bleach, scouring powders, solvents or other aggressive cleaning agents. To clean, use warm soapy water and a clean cloth and rinse off.
Please note: There has been a glass coating applied to this product, use a squeegee to remove water and debris.
Periodically check all fixings and tighten if necessary.
8
CORAM SHOWERS LTD
Stanmore Industrial Estate, Bridgnorth, Shropshire WV15 5HP, UK • Tel: 01746 766466 • Fax: 01746 764140 • www.coram.co.uk
Check contents of pack before installation. If anything is missing, contact our Customer Careline for assistance.
SLIDING DOOR CONTENTS
PN3230
8
PN80519
2
PN3225
32mm
PN60014
8
1500 =
PN40272
1700 =
PN40273
4
2
PN40260
13mm
PN3222
10
PN80564
2
10mm
PN4748
1
14
PN40259
PN50103
2
8
PN60250 4
PN4745
8
PN50382
4
PN60418
1 PN60058
1
1 a
=
=
ø 4.5
mm
100mm max
100mm max
=
1500 RAIL - PN80531
1700 RAIL - PN80532
PN10801
PN10801
1500 RAIL - PN80531
1700 RAIL - PN80532
PN3222
SIDE PANEL CONTENTS
3
10mm
PN4748
3 b
2 a: Drill holes in both wall channels at points shown using a 4.5mm drill bit, where shown. b: Ensure the shower tray is level in all directions. IMPORTANT: Clean the tray and seal the gap between the tray surface and tiles.
It is important that the tray is sealed right up to the tray edge so that the bottom of the wall channel is sealed. Failure to do this will cause water to leak under the wall channel and between the tray and tiles, resulting in damp patches on the wall and under the tray.
The enclosure can be assembled with the side panel on either the right or left (see step 4).
Note: The following instructions show the enclosure with the side panel on the left.
9
3 a
X
Y b
ø 6.5
mm c
32mm
Inside
X = Door widths
1500 = 1450 - 1500mm
1700 = 1650 - 1700mm
Y = Side Panel widths
700 = 670 - 695mm
760 = 735 - 760mm
800 = 775 - 800mm
900 = 875 - 900mm a: Place the wall channels on the tray ensuring they are vertical and an equal distance back from the front of the tray.
Place masking tape against the wall before marking drill hole positions, this will help prevent the drill bit slipping. Drill 6.5mm holes, 30mm deep and insert the wall plugs. b: Apply sealant to the back of the wall channels. c: Fix the wall channels to the walls using 8 x 32mm screws and screw caps.
4 a b
ø 3 mm
Inside side panel
10mm a: Insert the side panel into the wall channel ensuring that the corner post is the same distance in from the edges of the tray as the wall channels. b: From inside the enclosure, in the positions shown, drill through the wall channel into the side panel using a 3mm drill bit, do not drill too deep! Fix using 3 x 10mm screws and screw caps.
10
5 a b
=
6
= a: Place the bottom rail onto the tray with its end mouldings inserted into the corner post and wall channel. b: Centre the bottom rail between the corner post and wall channel so that there is an equal gap at each end.
7
Outside face of fixed panel
Outside face of fixed panel
Outside face of fixed panels
Fixed panel bracket
Push fit the 'short flipper seals' onto the top and bottom edges of the fixed panels - flush against the metal profile.
Ensure the flipper seal 'flaps' are on the inside of the fixed panels.
Note: Wetting the glass with water will help to fit the seals.
Position the fixed panels into the corner post and wall channel and slide down so they fully slot onto the end mouldings of the bottom rail. Inside the enclosure, ensure the panels sits in the 'fixed panel brackets', slide the brackets along the rail and position under the panels as shown.
11
8
13mm
Inside
Position the top rail onto the top of the
'fixed panels'. Adjust the position of the fixed panel brackets as required.
Line up the holes and fix using 2 x 13mm screws.
9
ø 3 mm
From inside
10mm
Check the door frame is vertical and is centrally positioned between the corner post and wall channel.
From inside the enclosure, in the positions shown, drill through the corner post and wall channel into the fixed panels using a
3mm drill bit, do not drill too deep!
Fix using 6 x 10mm screws and screw caps.
12
10
PN40260
Inside
PN4745
Fit 'flipper seals' (PN40260) onto the edge of the fixed panels. Ensure the flipper seal 'flaps' are on the inside.
Note: Wetting the glass with water will help fit the seals.
From inside the enclosure, tighten all 4 fixed panel bracket grub screws onto the glass using the allen key - do not overtighten . Fit the cover caps (PN4745) into the holes.
12
11
PN
40259
Outside face of door
PN80564
PN40259
PN80564
Outside face of door
PN80564 Door handle hole
Door handle hole
Push fit 'flipper seals' (PN40259) onto the back edge of the doors.
Ensure the flipper seal 'flaps' are on the outside of the doors.
Push fit 'magnetic seals' (PN80564) onto the closing edge of the doors (the same side as door handle hole).
Note: Ensure the magnetic seals are positioned as shown.
Note: Wetting the glass with water will help fit the seals.
From inside
Top of doors
Bottom of doors
IMPORTANT: It is advised that this stage is carried out by two people to avoid damaging the runners, rails or doors.
From inside the enclosure, push fit the 'runners' fitted to the top and bottom of the doors, onto the 'door rollers' pre-fitted in the top and bottom rails.
13
13
From inside a b c
PN50103
The 'cam adjusters' at the top and bottom of the doors may need adjusting so that the doors slide freely and the magnetic seals meet evenly when the doors are closed. a: Loosen all 4 cam adjuster screws on each door (1 turn maximum). b: Turn the cam adjusters (by hand or using a 16mm spanner) until the doors hang vertically. Re-tighten the screws - do not over tighten . c: Push fit all 8 covers onto the doors.
14
Fit the door handles to the door ensuring the supplied handle washers are used on each side of the glass.
Chrome finish handle are supplied for all frame finish options.
15
PN60250
PN60250
Push fit all 4 covers (PN60250) onto the middle door stops on the top and bottom rails.
14
16
18
PN60058
Lubricate the inner top and bottom rails using the wipe provided.
17
Fit the Bump Stops to the rail, top and bottom as shown on the fixed panel side. Tighten the screw with a screw driver, do not over tighten. Place cover cap in the hole.
From the outside only , apply sealant to the bottom of the enclosure and 50mm up the wall channels and vertical joints as shown.
50mm
15
Recycling
Packaging :- The cardboard and polythene parts of this packaging can be recycled.
End of life :- This product contains materials such as aluminium and glass which can be recycled.
Please contact your local authority to find your nearest recycling centre.
IMPORTANT: You must not use the shower for 24 hours after installation of the enclosure.
DO NOT use bleach, scouring powders, solvents or other aggressive cleaning agents. To clean, use warm soapy water and a clean cloth and rinse off.
Please note: There has been a glass coating applied to this product, use a squeegee to remove water and debris.
Periodically check all fixings and tighten if necessary.
CORAM SHOWERS LTD
Stanmore Industrial Estate, Bridgnorth, Shropshire WV15 5HP, UK • Tel: 01746 766466 • Fax: 01746 764140 • www.coram.co.uk

Public link updated