Advertisement
Advertisement
INSTRUCTION SHEET ERICO® DYNASPHERE MKIV Installation Instructions for 8m Aluminum Cantilevered Mast Terminal Elevation: 6m Above Structure 6.6FT [2M] 19.7FT [6M] 6.6FT [2M] Overlap with structure |, Final position of the FRP Mast and the ERICO DYNASPHERE ERICO DYNASPHERE (ERICO® Part # D/SMKIV-SS) ERICO® ERICORE Downconductor with factory fitted upper termination ERICO ERICORE Downconductor FRP Upper Support Mast 2M (ERICO Part # FRP2MBLACK) (ERICO Part # ILCOUPL) Stainless Steel Cable Tie (ERICO Part # CABTIE-S/S) Install on the Aluminum Mast every 3.3FT [1M] Typical Conductive Saddle for ERICO ERICORE Cable (ERICO Part # CONSAD/E2/5) Self Tapping Screws (ERICO Part # CONSAD—FX) Y — 6M Aluminum Mast (ERICO Part # ALUM6M) J (5) Heavy Duty Offset Mounting Brackets (ERICO Part. # 7000250S4) Refer to Detail ”А” (Equally spaced) Lightning Event Counter (ERICO Part # LECIV) Refer to installation manual for alternate locations. ERICO ERICORE Downconductor (Minimum Bending Radius 40” [0.5M]) For complete Grounding System refer to Detail ”B” — | Lower Termination Kit (ERICO Part # ERICORE/LTKIT/A) Ground Rod ——— Lower Termination Kit (See Detail), Ground Rod Connection included in the kit. WARNING: Detail "A" LE TA ch or, 9-5/8” [244mm] 8-3/8” [213mm] | | о оо Le 3/8” [9.5mm] Bolt Detail “В” Lightning Event Counter (ERICO Part # LECIV) ERICO ERICORE Downconductor ERICO® CADWELD® Connection or mechanical connection Crow’s Foot Ground Inspection Well Bond to the existing building ground system with ERICO CADWELD Connection Minimum 2/0 (50mm?) Conductor (3 x 20FT [6.1M] Length) Enclosed in GEM material Minimum 5/8” x 8” [16mm x 2.4M] ground rod in four locations The grounding system shown in the detail is a suggested layout. Each radial consists of a trench approximately 1.5FT [0.45M] deep. 3 x 20FT [6.1M] of 2/0 conductor is laid in the trench and is connected to ground rods. The conductor in each trench is encased in GEM material. Ground rods must extend 10FT [3M] below ground level. Note: This is one of several alternative installation methods. Refer to ERICO instruction print IP79157 for more details. ERICO is not responsible for field installaion of lightning protection systems. The installation integrity of each system should be approved and stamped by a structural professional engineer. 1. ERICO products shall be installed and used only as indicated in ERICO product instruction sheets and training materials. Instruction sheets are available at www.erico.com and from your ERICO customer service representative. 2. ERICO products must never be used for a purpose other than the purpose for which they were designed or in a manner that exceeds specified load ratings. 3. All instructions must be completely followed to ensure proper and safe installation and performance. 4. Improper installation, misuse, misapplication or other failure to completely follow ERICO’s instructions and warnings may cause product malfunction, property damage, serious bodily injury and death. SAFETY INSTRUCTIONS: — TECHNICAL SUPPORT: www.erico.com IP7977_C All governing codes and regulations and those required by the job site must be observed. Always use appropriate safety equipment such as eye protection, hard hat, and gloves as appropriate to the application. CADDY, CADWELD, CRITEC, ERICO, ERIFLEX, ERITECH, and LENTON are registered trademarks of ERICO International Corporation. ® 1 OF 1 ©2006,2014,2015 ERICO International Corporation ERICO ">

Public link updated
The public link to your chat has been updated.
Advertisement