DoorHan FAST-750 Installation And Operating Manual
DoorHan FAST-750 is a high-speed door operator designed for intensive use in commercial and industrial applications. With its powerful motor and robust construction, the FAST-750 can handle doors weighing up to 1000 pounds and opening speeds of up to 100 inches per second. The FAST-750 also features a number of advanced safety features, including automatic obstacle detection and a built-in warning alarm. Whether you need to improve security, enhance convenience, or increase productivity, the DoorHan FAST-750 is the perfect solution for your high-speed door needs.
Advertisement
Advertisement
OPERATOR
SECTIONAL-750/1000/1200/FAST-750
CONTENTS
GENERAL INFORMATION
SAFETY INSTRUCTIONS
OPERATOR UNIT
OPERATOR INSTALLATION
ELECTRICAL CONNECTIONS
OPERATOR PROGRAMMING
REMOTE CONTROL PROGRAMMING
MANUAL OPENING
MAINTENANCE
TROUBLESHOOTING
10
13
6
9
4
5
2
2
14
15
15
Installation and Operating Manual
© DoorHan, 2014
Actual versions soft - v 1.0
pcb - v 1.0
CONTENTS
CONTENTS
1. GENERAL INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
1.1. Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.2. Operator package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.3. Track . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2. SAFETY INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
3. OPERATOR UNIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
4. OPERATOR INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
4.1. Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
4.2. Requirments to door installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
4.3. Connection of operator and guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
4.4. Track installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
5. ELECTRICAL CONNECTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
5.1. Сontrol block technical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
5.2. Сontrol block wiring diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
5.3. Photocell installation (option) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
6. OPERATOR PROGRAMMING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
6.1. Operator control keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
6.2. Prepartion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
6.3. Upper door position . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
6.4. Low door position . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
6.5. Automatic force setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
6.6. Force limit setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
6.7. Warning alarm set up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
6.8. Automatic closing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
6.9. Turning sound alarm after 2000 cycles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
6.10. Turning high speed opening/closing (for operator FAST-750 only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
6.11. Completing the programming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
7. REMOTE CONTROL PROGRAMMING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
7.1. To add a remote control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
7.2. Remote programming for Doorhan remote controllers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
7.3. MARKING remote control buttons DOORHAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
7.4. To erase a remote control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
8. MANUAL OPENING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
8.1. Opening by means of integrated carriage releasing device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
8.2. Opening with external releasing device (optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
9. MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
10. TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
11. APPENDIX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
1. GENERAL INFORMATION
The Sectional-750/1000/1200/Fast-750 electromechanical chain operator is designed for automation of residential sectional doors.
It consists of an electromechanical motor reducer, an electronic control unit and an illuminating lamp, incorporated into a housing. The electric operator is easily secured on a track and mounted to the ceiling, opening of the doors is carried out by means of a chain/belt gear. The self-locking operator gear ensures mechanical interlocking of the doors, if engine is not functioning, but in the absence of electric power the manual emergency release allows you to open and to close the doors manually.
For maximum safety, the control unit has force protection.
Besides, optionally, the operator can be equipped by electronic protective sensors, which stop the doors closing, if there are obstacles or people within the operating range of automatic system.
2
GENERAL INFORMATION
1.1. Specifications
Parameters
Power voltage
Current frequency
Motor voltage
Max. power consumption
Max. force
Use type
Light lamp
Lamp socket type
Lamp shutdown time
Basic carriage rate
Door width, max.
Door height, max.
Door area, recommended
IP rating (for dry locations)
Working temperature range
Fuse type
Transmitter frequency/range
Guide type
1.2. Operator package
When you receive your Sectional-750/1000/1200/Fast-750 operator, unpack it and check that the operator is not damaged. If any damages are found, contact the operator supplier.
The operator components included in the standard package are listed in the following table.
Electric operator
Guide fastening bracket
Sectional-750/FAST-750
150 W
750 N
0,1/0,18 m/sec
<10 m 2
Chain/belt
Sectional-1000
180–240 V
50 Hz
24 V (DC)
250 W
1 000 N
Intermittent operational mode - 5 minutes
230 V / 25 W max.
E14
300 sec.
5 000 mm
Depending on the guide used
0,1 m/sec
<13,5 m 2
IP20
–20…+55 °C
Power fuse 1: 2.5a; lamp fuse 2: 2.5a: Sr F2.5a (fast)
433 MHz/up to 50 m (in open field)
Chain
Sectional-1200
300 W
1 200 N
<16 m 2
Operating manual
ПРИВОД
SECTIONAL-750/1200/FAST-750
СОДЕРЖАНИЕ
ОБЩИЕ СВЕДЕНИЯ
ПРАВИЛА БЕЗОПАСНОСТИ
УСТРОЙСТВО ПРИВОДА
УСТАНОВКА
ЭЛЕКТРИЧЕСКИЕ ПОДКЛЮЧЕНИЯ
ПРОГРАММИРОВАНИЕ ПРИВОДА
ПРОГРАММИРОВАНИЕ ПУЛЬТОВ ДУ
РУЧНОЕ ОТКРЫВАНИЕ
11
11
ОБСЛУЖИВАНИЕ
ДИАГНОСТИКА НЕИСПРАВНОСТЕЙ
12
12
Инструкция по монтажу и эксплуатации
© DoorHan, 2012
Headroom bracket
Guide Curved arm U-shaped bracket
Straight arm fastening bracket Mounting bracket to the ceiling Slotted bushing
Remote control Fastening set
№
1 Electric operator
2 Operating manual
3 Guide
4 Curved arm
5 U-shaped bracket
6 Guide fastening bracket
Name Quantity
1
1
1
1
3
1
№
7 Headroom bracket
Name
8 Straight arm fastening bracket
9 Mounting bracket to the ceiling
10 Slotted bushing
11 Remote control
12 Fastening set
Quantity
1
1
2
1
1
1
3
SAFETY INSTRUCTIONS
1.3. TRACK
Guide model
SK-3600 (chain)
SK-4200 (chain)
SK-4600 (chain)
PK-3600 (belt), option
PK-4600 (belt), option
Guide length, L
3 620
4 220
4 620
3 620
4 620
Travel
2 800
3 400
3 800
2 800
3 800
Opening height
≤ 2 800
≤ 3 400
≤ 3 800
≤ 2 800
≤ 3 800
2. SAFETY INSTRUCTIONS
IMPORTANT! You should observe the safety regulations to preserve people’s health. You must keep the present Manual.
You should follow all the recommendations of the given Manual, as incorrect equipment installation could lead to serious damages.
The Sectional-750/1000/1200/Fast-750 operator is designed for automation of residential sectional doors. It should be used only for the purpose intended; any other use is forbidden.
DoorHan is not liable for personal injuries, if the product was used for purposes other than intended.
Make sure that the doors are balanced and function smoothly before installing the operator.
The installation is to be carried out according to the standards EN 12453 and EN 12445. For providing the required safety level, these requirements should be observed in non-EU countries.
You should check if the doors conform to the standards EN 12604 and EN 12605 (see documentation on the doors). For non-EU countries these measures are to be observed for ensuring the normal safety level.
The mechanical door assembly units must conform to the provisions of the standards EN 12604 and EN 12605.
Before installing the operator, make sure that the mounting location by its climatic conditions corresponds to the operator’s specifications.
You should not install the equipment in rooms with highly flammable substances or other hazardous media, as this can сред, result in explosion or fire.
You should use tools, indicated in Section “Tools” of the given Manual, during assembly, installation and adjustment of the operator.
You should use a stable support when working at height.
The operator is allowed to install at more than 2.5 m height.
You should use hand and face protection when drilling holes.
You should use metal goods from the operator package or other goods equivalent to them for fastening the product.
You should power off when performing installation, cleaning or maintenance of the operator.
When mounting the operator on doors with the infitting pass door, it is necessary to install an additional safety device, which prevents the operator activation, when the door is open.
Make sure, that there will not be trapping of articles between movable and fixed elements of the operator when the doors move.
You should use additional DoorHan accessories, since the accessories of third party manufacturers can damage the automatic system.
DoorHan is not liable for unstable work of the automatic system, if you use safety devices and accessories, produced by other manufacturers without securing approval of DoorHan.
You should not leave electric engines in a released state. This can lead to uncontrolled movement of the door wings and, as a result, to their damage.
You should not use the operator, if it is necessary to repair or to adjust the equipment, since defects during the assembly of the operator or incorrectly installed doors can result in injury.
DoorHan is not liable, if the product is not correctly installed or is damaged during operation.
The electric operator is not equipped with the stationary power cord; therefore mains supply is to be fed to the automatic system via an automatic switch with a distance between the adjacent contacts minimum 3 mm. It is recommended to use double pole circuit breaker 10 A.
Make sure, that there are no foreign bodies within the operating range of the electric operator before its start.
You should not introduce changes, not stated in the given Manual, into the automatic system.
You should remove the product package and dispose of it. You should not leave the packaging materials within the reach of children.
4
2
4
3
1
SAFETY INSTRUCTIONS
You should not allow children to play in the door movement area during the operator operation. All remote control panels and also stationary control buttons must be absolutely inaccessible for possible use by children.
It is allowed to drive in and to pass only when the doors do not move and the operator is switched off.
The contents of the Manual could not serve as a basis for laying claims of any kind.
The manufacturer reserves the right to introduce modifications into the structure and to improve it without prior notice.
IMPORTANT!
For safe and correct work of the operator it is necessary to install a mechanical stop to limit the door leaf motion.
WARNING!
RISK OF INJURY!
Have a qualified technician lay the cables 230 V AC. The cables must be laid in protective corrugated tubes. In case of supply cable damage, use the suitable type of the cable.
Cables needed for installation of Sectional-750/1000/1200/Fast-750 operator and accessories (if available):
Cable 2 x 0.5 mm 2 (photocell transmitter).
Cabel 4 x 0.5 mm 2 (photocell receiver).
Cable 3 x1.5 mm 2 (power supply).
The cables should be appropriately insulated.
6
5
3. OPERATOR UNIT
9
8
3
10
1. Low housing cover
2. Top housing cover
3. Panel cover
4. Gearmotor
5. Bushing
6. Microswitch
7. Light lamp
8. Transformer
9. Control board
10. Protective cover
7
5
OPERATOR INSTALLATION
4. OPERATOR INSTALLATION
1. Set of spanners
2. Set of slotted and cross screwdrivers
3. Set of drills for metal
4. Set of drills for concrete
5. Pliers
6. Hacksaw for metal
4.2. Requirments to door installation
Prior to installation check if the door is properly balanced and moves smoothly when automatically operated.
Make sure, that minimal clearance between the ceiling and the top point, when the door is moving, is not less than 45 mm (pic. 1).
Check, that the door leaf top roller is in the horizontal part of the guide rail, when the door is completely closed
(pic. 2).
45 мм
7. Electric drill
8. Tape measure (folding rule)
Pic. 2
4.3. Connection of operator and guide
1. Put the operator bushing (4) on the shaft (5).
2. Insert the operator unit into the hole on the guide (3).
3. Fasten the operator with U-brackets (2) and tapping screws (1).
5
4
3
2
1
1. Motor shaft
2. Bushing
3. Guide
4. U-bracket
5. Tapping screws
Pic. 1
6
OPERATOR INSTALLATION
NON-STANDARD INSTALLATION
1. When doing a non-standard installation of the operator (at an angle of 90°). the microswitch.must be moved to a special place. To do this: a) Disconnect the bottom cover of the housing and disconnect the microswitch contact of the board.
b) Disconnect the microswitch of the top housing cover.
c) Squeeze in the new microswitch location the plug out of the hole and pull through it the microswitch contact and connect it to the board.
d) Secure the microswitch (1) on the top housing cover with the help of self-drilling screws.
e) Mount the body of the operator.
2. Install the splined bushing (3) on the motor shaft (2).
3. Insert the motor (2) in the guide hole (4).
4. Secure the motor by means of U-brackets (5) and self-drilling screws (6).
1. Microswitch
2. Motor shaft
3. Splined bushing
4. Guide
5. U-bracket
6. 6 x 15 self-drilling screws
6
5
4
3
2
1
7
5.1
5
5.4
8
OPERATOR INSTALLATION
4.4. TRACK INSTALLATION
The operator suspension height is determined by the maximum lift of upper edge of the door leaf. After preliminary assembly
(see p. 4.3) you can start to install the track:
1. If it is required to shorten a guide, it is necessary to fulfill operations, described in Appendix 1.
2. You should mark a vertical line, corresponding to the horizontal door centre (Fig. 5).
3 You should place a lintel mounting bracket (1) in such a way that the distance from upper edge of the open door leaf to lower edge of the track amounted to minimum 10 mm (Fig. 5.2) and fix it to the lintel using self-tapping screws (2) (Fig.
5.1).
4. You should fasten the track (3) and the lintel mounting bracket by means of a track fixation bolt (4) (Fig. 5.3).
5. You should install a U-shaped bracket (5) on the track approximately at a distance 2/3 L and attach it to the ceiling (Fig.
5.4).
6 You should install track mounting brackets (6) on the track approximately at a distance 1/3 L and attach them to the ceiling (Fig. 5.5).
7. You should install a rod-to-leaf mounting bracket (7) in the middle of the upper aluminium profile of the door leaf and fix it using self-tapping screws (8) (Fig. 5.6).
8. You should attach a cranked rod (9) to the rod mounting bracket and fix it by means of a pin axle (10) (Fig. 5.7). It is allowed not to mount the cranked rod, if α angle is observed.
B/2
B
α
∼ 1/3L
L
∼ 2/3L
30° < α < 60°
Стена
Ворота
1. Lintel mounting bracket.
2. Anchor bolt.
3. Track.
4. Track fixation bolt.
5. U-shaped bracket.
6. Track mounting bracket.
7. Rod-to-leaf mounting bracket.
8. Screw 6x15.
9. Cranked rod.
10. Pin axle.
Figure 5
1
2
10
5.2
5.5
6
5.6
4
5.3
7
8
5.7
3
10
α
9
ELECTRICAL CONNECTIONS
5. ELECTRICAL CONNECTIONS
5.1. Сontrol block technical specifications
Parameters
Power voltage
Accessories power voltage
Accesories max. current
Working temperature range
Radio control frequency
Operating logics
Connecting sockets
Lamp lighting time
Fuse type
Specifications
180–240 V / 50 Hz
24 V DC
200 mA
–20…+55°C
433 MHz
Automatic/semiautomatic
Open button / safety device
3 min
Fast, fusible, 230 V, 2,5 а, Sr F2,5a
5.2. Control block wiring diagram
WARNING!
The cable wires must be protected from contact with any rough or sharp parts. All connections shall be made only when power is off.
LED3
Photosells
NO NC
VCC (+2
Antenna
COM
NO
NC
ANT
GND
IR
GND
24V
... ...
LAMP
24V DC
– + – +
Black
BATTERY 24V
Red
Observe the polarity!
To lightening lamp
(built in operator housing)
Supply voltage of motor
12 V AC (after transformer)
.. ... .....
12V PE
COM NO NC
Emergency stop button
9
OPERATOR PROGRAMMING
5.3. Photocell installation (option)
INSTALLATION
It is recommended to install photocells at a height of not less than 20 cm and not more than 2 m.
The photocells must be installed vertically and parallel to each other (see Fig. 6).
The first to be installed and connected is the receiver, and after that - the transmitter.
Move the transmitter when installating, till the photocells become parallel to each other. In this case, the receiver turn-off lamp will turn off, then fasten the transmitter.
The installation is complete.
CARE AND MAINTENANCE
Due to propagation properties of infrared radiation, an incorrect function of the system is possible at a small distance between the transmitter and the receiver. The distance between them should be at least 1 meter. If the receiver sensitivity at a small distance between the transmitter and the receiver is insufficient, remove the lens of the receiver in order to increase its sensitivity.
Avoid direct sunlight!
18 40
Select the desired mode of the photocells with respect to the control contacts: NO (normally open) or NC (normally closed). If necessary, change the jumper position NO / NC.
DOORHAN
For steady work, the maximum distance between the photocells must not exceed 25 m. In bad weather (fog, rain, etc.) the coverage may be reduced by 30%
OPERATIONAL RECOMMENDATIONS
Keep photocells clean; if necessary, wipe the front of the sensors from dust and dirt.
At least once a month, check the correct operation of the photocells (in presence of obstaclesbetween the photocells, the gates should be left open during the commands and when closing thegate, they have to go to reverse or stop)!
Install a jumper on the photodetector for work with the NC (normally closed) contacts.
18 40
DOORHAN
Figure 6
6. OPERATOR PROGRAMMING
6.1. Operator control keys
To gain access to the panel programming, remove the protective cover with the logo DoorHan.
1
2
3
4 1. Radio code recording button –— «R»
2. Programming button — «Р»
3. Display unit
4. Setting buttons — «+», «–»
10
OPERATOR PROGRAMMING
6.2. Preparation
Block the carriage.
Turn on power, the indicator of the operator will light, sound signal will be heard.
If programming has not been completed, the settings will not be stored. If there is a mistake in one of the settings, you can turn off power and reprogram.
6.3. Upper door position
Press and hold down the button «P» during about 5 sec
«1» will light Press «P»,
«1» will flash upper position required.
the information
The setting will be stored only when you program the UPPER door position. The upper position shall be programmed before setting the lower door position.
6.4. Low door position
«2» will light Press «P», «2» will flash замигает When pressing «+» and «-», set the door panel into closed position.
The setting will be stored only when you program the LOW door position.
6.5. Automatic force setup
Press «P» to save the information
Press «+»,
«3» will light
Press «P», «3» will flash
The door automatically performs the full cycle (opening/closing), then a beep will sound, and the program comes out of programming mode automatically «3» will light
After finishing the automatic force setup, a beep will sound, and the program comes out of programming mode automatically.
After performing these setups, the programming can be finished; all other parameters have factory settings.
6.6. Force limit setup
By default, the operator is set on the 3rd sensitivity stage; usually the customers do not need to change these settings.
Factory setting
«4» will light, press «P» again
When pressing «+» and «-», select an operator force function value: «1» – minimum force value, «6» – maximum force value. Press «P» to save the information
The door function may be disrupted by setting maximum or minimum sensitivity value!
Press «P» to save the information
11
OPERATOR PROGRAMMING
6.7. Absolute cycle counter
Press «+» «5» will light, press
«P»
The 1st digit will be displayed
The 2nd digit will be displayed
When entering the 5th point of menu, two digits will be displayed sequentially. After having displayed the digits, the program returns to main menu.
The first digit – tens, the second digit – units.
The value received is multiplied by 1000 to receive information on amount of cycles driven by the operator.
6.8. Warning alarm setup
In the case you forgotten to close the door, after 10 minutes a warning alarm will sound. This signal will be turned off automatically after the door will be closed. The factory setting of this function is “0” – the function is off.
Press «+» «6» will light, press «P»
6.9. Automatic closing
When pressing «+» and «-», select a function value: «0» – off, «1» - on
Press «P» to save the information
Нажмите «+» — загорится «7»
7» will light
P -
+
P -
+
When pressing «+» and «-», select a function value: «0» -
no automatic closing, «1» - pause 30 sec, «2» - pause
60 sec ..., «8» - pause 240 sec.
P
Press «P» to save the information
-
+
P
6.10. Maintenance counter after 2000 cycles (factory setting: «0» – the function is off)
+
-
Нажмите «P»
Press “P”
Нажмая «+» или «–» выберите значение
When pressing «+» and «-», select a function value: «0»– off, «1» – on
Нажмите «P» для сохранения
Press «P» to save the information
6.11. Completing the programming
Press «+» or «-», select «1». Press and hold down «P» until «0» appears on the display. The programming is complete.
12
REMOTE CONTROL PROGRAMMING
7. REMOTE CONTROL PROGRAMMING
7.1. To add a remote control
1. Press and hold the «R», until «00» appears on the display. Release the button.
2. Select on the control panel the button, with the help of which you will control the operator’s work, and press it twice.
3. Repeat above operations for other remote controls (maximum quantity — 20 pcs.).
4. All the remote controls will be added sequentially into the control block.
5. When the maximum quantity of remote controls is exceeded; three long beeps will sound.
7.2. Remote programming for Doorhan remote controllers
1. To press and hold the button «2» of the programmed remote control.
2. Without releasing the pressed button «2», to press and hold the button «1» of the remote control.
3. Release the buttons pressed.
4. Press the remote control button already set up.
5. On the new remote control, select a button with the help of which you will control the operator’s work, and press it twice. A beep will sound.
NOTE
It is possible to add all four control buttons into the operator.
7.3. MARKING remote control buttons DOORHAN
3
1
2
4
3 2
1 4
1
2
1 2
7.4. To erase a remote control
To delete the remote controls from the receiver memory, press and hold down the button “R” for 10 seconds until the long beep will sound, what means erasing a remote control in the operator.
WARNING!
If the remote control is lost, it is necessary to erase the radio codes and reprogram the remote controls to avoid unauthorized access.
13
MANUAL OPENING
8. MANUAL OPENING
8.1. Opening by means of integrated carriage releasing device
Manual disengagement of automatic system Manual door control
Figure 7
Locked position Pull the cord down and move the rod to the position shown in the
Figure
Unlocked position
Automatic door control
Figure 8
Unlocked position Pull the cord down and move the rod to the position shown in the
Figure
Locked position
I n the event of main power failure
In the event of main power failure, the operator can be switched to manual control. To do this, pull down the releasing device cord. The carriage should withdraw from the engagement, amd after that the door can be operated manually
(Fig. 7).
When main power is restored
When main power is restored, the operator is to be set to automatic control. To do this, move the carriage into the locked position by pulling the releasing device cord to youself (Fig. 8). After this, trigger a signal from the remote control or control button, wait till the carriage clutch with chain (belt).
8.2. Opening with external releasing device (optional)
The external emergency rope releasing device is intended for manual emergency unlocking the door from street side in case of supply voltage shutdown or automatic system failure in order to gain access to the room through the passage, secured by the door (in the abscence of a wicket-door or additional entrance to the room).
When installing an external releasing device, use the appropriate instructions. It is recommended to use an external releasing devices LOCK or LOCK N. Do not install the releasing devices of other manufacturers in order to avoid failure of the system!!
14
MAINTENANCE
9. MAINTENANCE
The Sectional-750/1000/1200/Fast-750 automatic system does not require any special servicing.
Repairs may be carried out only by a qualified technician trained and certified at an authorized DoorHan centre.
Be sure that after completion of installation the installer has shown the user how to release the door in case of emergency and has given instructions on proper operation and maintenance of the automated system.
When carrying out maintenance, it is recommended to use DoorHan original spare parts.
Carry out maintenance of the automatic system at least every six months.
Regularly check if the door is properly balanced and moves smoothly when automatically operated.
Regularly check if the safety devices are in good working condition.
In case of power failure you may need to restore operator’s settings. Once the power supply is restored, check the automatic system for proper operation. If the operator settings have changed reprogram them following the instructions given in the corresponding paragraph of this manual.
In case of power failure the door will stop. As soon as power supply is restored you can control the opera tor as usual.
After expiration of life time, the item shall be delivered in a specialized disposal point!
If you have lost this Manual, you may request for the duplicate copy to the following address: Kralovsky
VRCH 2018, Kadan, 43201, Czech Republic, or by e mail: [email protected].
The producer (DoorHan) does not supervise the installation of operators, or carry out their maintenance, thus DoorHan cannot be held liable for safety of installation, operation and maintenance of the equipment.
10. TROUBLESHOOTING
Trouble
The perator does not work
The door does not open with the remote control
Remote control sensing distance too small
The guide chain moves, but the door does not move
Possible causes
1. No power supply
2. The fuse is blown
1. Remote control code is not recorded
2. Remote control battery is low
Remote control battery is low
Sound alarm is on
The carriage is disengaged and not connected to the chain support
1. The door is open
2. Audible warning of used 2000 cycles formaintenance
The door does not reach the end position or does not work
The door works intermittently, but the indicator lights «H»
The door suddenly stops, the indicator lights «F»
When the system is workung, a creak is audible
The chain generate noises and frictions with the guide
Error when programming
Electronics failure due to high humidity
1. The door met an obstacle, orthe mechanics is jammed
2. Power supply is unstable
Lack of lubrication of the guide chain after prolonged working
The chain elongated
Solution
1. Tur the power on
2. Replace the fuse
1. Re-record the remote control
2. Replace the battery supply
Replace the battery supply
Align the carriage with the support and engage the carriage
1. Close the door
2. Turn off the power and turn it on again
Perform programming
Clean the control board (by technician)
1. Check the door mechanics, remove the obstacle
2. Check the supply voltage
Lubricate the chain
Lubricate the chain gearwheel and tension the chain
15
16
APPENDIX 1
APPENDIX 1
GUIDE CUTTING
1. Unpack a guide and inspect it. Make sure that the guide is not damaged. If you have found any damages, please contact the supplier.
2. Disassemble a chain tensioner mechanism, pos. 1 (Fig. 1).
1
3. Unfasten screws of a sprocket holder, pos. 2 (Fig. 2).
Figure 1
2
Figure 2
4. Remove a chain with a carriage mechanism, pos. 3 (Fig. 3).
3
Figure 3
5. Disassemble a support, pos. 4, into two parts (Fig. 4).
4
Figure 4
6. Cut the guide and shorten the chain to the required dimensions (Fig. 5).
APPENDIX 1
7. After cutting assemble the guide in reverse order.
Figure 5
17
We very much appreciate that you have chosen the product manufactured by our company and believe that you will be satisfied with its quality.
For information on purchasing, distribution and servicing
contact DoorHan central office at:
Kralovsky VRCH 2018, Kadan,
43201, Czech Republic
Telephone: +420 474 319 111
E-mail: [email protected] www.doorhan.cz

Public link updated
The public link to your chat has been updated.
Advertisement
Key features
- High-speed operation (up to 100 inches per second)
- Powerful motor can handle doors weighing up to 1000 pounds
- Advanced safety features, including automatic obstacle detection and a built-in warning alarm
- Easy to install and program
- Compatible with a wide range of door types and sizes
- Durable construction for years of trouble-free operation