Aesfee AF-2018 User Manual
Aesfee AF-2018 is a fully-automatic blood pressure monitor that measures your blood pressure and pulse rate simply and quickly, using the oscillometric principle. It stores readings for two users, up to 99 readings per person, and features a built-in lithium battery with Micro USB charging port.
Advertisement
Advertisement
Please read the product manual before using, and keep it far future use.
Aesfee
Electronic Blood Pressure Monitor
User Manual
Model No: AF-2018
(Upper Arm type) .
English User Manual.
CONTENTS
114
Mode d'emploi en
francais
(French) 15 -28
Deutschsprachliches Benutzerhandbuch (Germany) ..........•......
Manual de usuario (Spanish) ..44-58
Manuale Italiano (Italy) 59-73
Thank you for purchasing the Aesfee AF-2018 Upper Arm Blood
Pressure Monitor.
The Aesfee AF-2018 is a fully automatic blood pressure monitor, operating on the oscillometric principle. It measures your blood pressure and pulse rate simply and quickly.
The monitor stores measurement results for two individual users (up to 99 readings per person). Built-in lithium battery for operation, and Micro USB port for charging, you can charge it by any DC 5V USBports such as USB charger, PC/Laptop, PowerBank ...
Please read this instruction manual thoroughly before using the unit. For specific information about your own blood pressure, CONSULTYOUR DOCTOR.
• Do not wash the arm cuff or immerse it in water .
• Do not take measurements after bathing, drinking alcohol, smoking, exercising or eating.
Ontology
@ Air Jock
®
Air Plug
©
Air Tube
@ Arm Cuff
®
Display Screen
®
USB Charging Port
©
Memory Button
®
Switch Button
CD
Setting Button
Consult your dactor during pregnancy, arrhythmia and arteriosclerosis.
Use the unit only to store the designated users measurement results.
Please read this section carefully before using the unit.
Caution:
(General Usage)
• Always consult your doctor. You should never stop or change the dosage of medication prescribed by your doctor.
• Do not leave the unit unattended with infants or persons who cannot express their consent.
• Do not use the unit for any purpose other than measuring blood pressure.
• Use only the approved arm cuff for this unit. Use of other arm cuffs may result in incorrect measurement results.
• Do not disassemble the unit or arm cuff.
• Make sure that the air tube is not wrapped around other parts of your body when taking measurements at night. This could result in injury when the air pressure in the air tube is increased.
• Do not wrap the arm cuff tightly when taking measurements at night.
This could result in injury.
• Do not use a cellular phone near the unit. This may result in incorrect operation of the unit.
• Do not operate unit in a moving vehicle (car, airplane).
• Do not use the USBcable to connect this unit when taking measurements.
• Do not inflate the arm cuff when it is not wrapped around your arm.
o
Q) Blood Pressure Level Indication
®
Time Icon
CD
Low Battery Symbol
@ High Pressure Yalue(Systolic Pressure)
® low Pressure Value(Diastolic Pressure)
@ Number of User Groups
®
Average Icon
@ Memory Icon
®
Number of Memory Groups
®
Heartbeat Icon
CD
Pulse Rate Display
• When the battery level is low and symbol' stop measuring.
~ ,
js
displayed, please
• Charge the monitor with 5V output voltage, the charging cable was included in the package.
• It will take 1 hour for the monitor to be full charged.
Last up to 300 measure times, standby time up to half a year.
v n If the batt ry is law, the previously measured blood pressure value will stili be stored.
•e
1.
Setting the blood pressure monitor
Check current se"'ng:
Press the S button" 0" to view the curren I settings such as time, date, user group number, blood pressure unit (kPa or mmHg)
To make use of the memory and average values functions:
,et the unit to the correct date, time, user group and blood pressure unit ietore taking a measurement for the first time.
1 Se"'ng the User Group
'ess and hold the S button" 0" for 3 seconds while the unit is turned off,
.ne Current user group icon lJ.
will flash on the display
• Press M button "8" to switch user group
• Press Switch button
"@" to save the setting and shut down.
1.2 Se"ing the data and time
1.) Press and hold the S button "0 "for 3 seconds while the unit is turned off,
The user group icon will flash on the display.
2.) Pressthe S button "0" again, the year digits0 2017 will flash on the display.
3.) Press the M button "8"to advance the digits one at a time.
4.) Press the S button "0" to confirm the setting when the desired number appears on the display.
The year is set and the month digits01/09 flash on the display.
5.) Repeat steps 3 and 4 to set the month,
The month is set and the day digits01/09 flash on the display.
6.) Repeat steps 3 and 4 to set the day.
The day is set and the hour digits018:59 flash on the display.
7.) Repeat steps 3 and 4 to set the hour.
The hour is set and the minutes digits018:59 flash on the display.
8.) Repeat steps 3 and 4 to set the minutes.
The minutes settings is set.
The unit automatically turns itself off after the minute setting has been set.
1.3 Se"ing the blood pressure unit
The default blood pressure display unit is in mmHg, and if you want to use kPa, please follow the steps below:
• Pressand hold the Switch button"
@ " for 6 seconds while the unit is turned off until "kPa" appear on the display.
• PressSwitch button to save the setting and shut down.
The blood pressure unit will appear as kPa in your next measurement .
2. How to Sit Correctly When Taking a Measurement
You can take a measurement on either your left or right arm.
Notes:
• Measurements should be taken in a quiet place and you should be in a relaxed, seated position. Make sure that the room is not too hot or cold.
• Do not take measurement after bathing, drinking alcohol, or exercising.
• Do not move or talk during measurement.
Remove tight fitting clothing from your upper arm, and any thick clothing such as a sweater.
Do not place the cuff over thick clothes and do not roll up your sleeve if it is too tight.
The gop between the choir and the top 01 the table should be between
25cm to 30cm.
Notes:
• Correct posture during measurement is necessary to get accurate results.
• You should also try to measure your blood pressure at the same time each day. (Within 1 hour after waking up is recommended.)
• Sit in a chair with your feet flat on the floor and place your armon a table so that the cuff will be at the same level as your heart,
Incorrect Posture
• Arched back (leaning lorwards),
• Sitting cross-legged,
• Sitting on a sola or at a low table so that you tend to lean forward, rr.
\
, '.•
L , ~
-------
These situations could lead to higher blood pressure values due to strain or the arm cull being lower than the heart,
II the arm cuff is at a lower position than your heart use cushions etc" to adjust the height of your arm,
Be sure to wrap the arm culf correctly so that you get accurate results,
Measurements can be taken in light clothing, However, please remove thick clothes, 'such as sweaters, before taking a reading,
3. Applying the Arm Cuff
You can wrap the cuff either on your right or left arm,
• Remove tight-litting clothing from your upper arm,
• Do not place the cufl over thick clothes and do not roll up your sleeve if it is too tight,
~
\,
~
~-:.::=====
• Insert the air plug into the air jack (on the left side 01 thedevice)
The cuff must be fully deflated when it is inserted into the air jack,
• Hold the grip on the cuff securely with your hand,
• Turn the palm of your hand upward,
• Apply the cuff to your upper arm so that the blue strip is centred on the middle of your inner arm and points down the inside 01 the arm, The air tube should run down the inside 01 your forearm and be in line with your middle finger,
The bottom 01 the cufl should be approximately 1 to 2 cm above the elbow,
Blue strip
Bottom edge 1 to 2 em
II
Air tube
o
When the cuff
IS positioned correctly, close the fabric fastener FIRMLY
Notes: o
Make certain the cuff fits snugly around yo o
The cuff should make good contact with your skin. You should be able to fit your index finger between the cuff and your arm easily, so you can pull the cuff off and on.
o
Make sure that there are no kinks in the air tubing.
Taking measurements on the right arm
Please note the following points when applying the cuff to your right arm. Apply the cuff so that the air tube is at the side of your elbow.
o o o o
Notes:
Be careful not to rest your arm on the air tube, or otherwise restrict the flow of air to the cuff.
Apply the arm cuff so that no part of the cuff is positioned over the elbow joint. The cuff should be 1 to 2 cm above the elbow.
If used 2 times per day, the cuff will last for 3 years.
The blood pressure can differ between the right arm and the left arm, and therefore also the measured blood pressure values can be different. Aesfee recommends to always use the same arm for measurement.
If the values between the two arms differ substantially, please check with your physician which arm to use for your measurement.
lalk during measurement.(lf mmHg appears on the screen, the measurement unit is mmHg, or kPa.)
Early display
I.)
~"
(!)14lT3
P
11 Q
Automatically charging
-+
(914113
II.
~"
110
When oir is slowly exbcvsted.vctoe
on the display screen drops/meanwhile heartbeat diagram
(heart shape) is flickering
-+
@(914113
I.)
I~,
•
120
80
70
After finishing measuring/the blood pressure monitor automatically exhausts air and displays blood pressure value and pulse rate.
1.2 View and Delete Memory
The unit is designed to store the blood pressure and the pulse rate in
Ihe memory for two people (user 1 and user 2) every time a measurement is completed.
The unit automatically stores up to 99 sets of measurement values (blood pressure and pulse rate) for each user (1 and 2).
When 99 sets of measurement values are stored, the oldest record is deleted
10 save the most recent values.
• View the records
Pressthe "8" button to display the most recent set of individual measurement values on the screen. The values are displayed from the most recent to the oldest. the first display is average value of the last three times of measurement.
Pressthe "8" button again the result from the most recent measurement is displayed. Pressthe "8" button repeatedly to cycle through the previous measurement results.
1. Measurement of Blood Pressure
1.1 Automatic Test
Press the Switch button, the arm cuff will start to inflate, do not move or average value for the 3 times measured value measured value measured value for the i st time for the 2nd time for the 3d time
-+ .
• Delete User Group Memory
The values stored in the memory are deleted by user ID.
You cannot partially delete values stored in the memory. All values for the user you select will be deleted.
• Select your ID (lor 2).
• Press the M button first to view mode.
• Press S button until" DEL" is displayed at the right corner of the screen, then Press M button again all the values will be deleted.
Delete All Memory
Press" 8" button while the unit is turned off, then press three button
(8 + 0) +@) simultaneously, release all button after the screen flicker all values will be deleted.
Abnormal phenomenon Cause Faulttreatment method
Position of arm cuff is not kept consistent with height of heart.
Moving or talking during measurement.
Keep correct posture during measurement.
Measured value is too high or too low.
Arm and shoulder muscles are tensed.
Keep silent and do not talk during measurement.
Stay relaxed and measure again.
Arm cuff is too loose or too tight.
Blood pressure value measured each time is different (reading too low or too high).
Measuring posture is wrong.
Wrap the arm cuff correctly.
Blood pressure value will chonge at different measuring times, and with different postures and degrees of reicxonon. Toke a deep breath before measuring 10 keep your body relaxed
Shutdown during measurement.
Low battery.
Charge the product.
No response when starting.
Low battery.
Charge the product.
• LCD Trror Tip and Corresponding Cause(table 1)
LCD error tip
"Er 1"
Couse
Make sure the gas in the arm cuff was out; Don't press the belt when measuring.
"Er 2" Don't move when measuring.
"Er 3" Abnormal test result. Please test again.
"Er 4"
"Er 5"
Belt was loose or air leak.
Trachea was stuck.
"Er 6"
"Er 7"
Too big interference.
Pressure beyond limit.
• Blood Pressure Warning Strip Illustration (table 2)
LCD
Severe
Moderate
Mild
Normal or High
Normal
Best
High pressure
;'180
160-179
140-159
130-139
120-129
,,119
Low pressure
;'110
100-109
90-99
85-89
80-84
,,79
Q&A
Q: What is blood pressure?
A: Blood pressure indicates the pressure borne by arterial vascular walls when the blood flows through the arterial vascular walls. During cardiac cycle, the blood pressure of the arterial vascular walls changes constantly.
o
The highest pressure during cardiac cycle is called high pressure value
(systolic pressure); the lowest pressure is called low pressure value (diastolic pressure).
o
The high and low pressure values are a necessary basis for diagnosis of blood pressure conditions of patients by doctors.
Q: What is irregular pulse wave?
A: Irregular pulse wave indicates instantaneous heartbeat rhythm is detected to exceed
25% out of the range of average heartbeat rhythm when the blood pressure monitor is used for measuring high and low pressure values.
If there is irregular pulse wave, please consult a doctor.
Q: What is arrhythmia?
A: Arrhythmia indicates abnormal heartbeat rhythm due to flaws in the bioelectric system that drives the heart. The classic symptoms are: o o o o o o o
Palpitations (a feeling of skipped heart beats, fluttering or "flip-flops," or feeling that your heart is "running away").
Pounding in your chest.
Dizziness or feeling light-headed.
Fainting.
Shortness of breath.
Chest discomfort.
Weakness or fatigue (feeling very tired).
Q:Why it is good to measure blood pressure at home?
A: Your blood pressure will be affected by body movement, anxious motion
, md different time periods in the day. A single measuring result cannot show
.rccorote
signs of blood pressure change.
Therefore, it is the best to measure
I ilooo pressure at the same time of each day to obtain accurate signs of blood pressure change.
Usually blood pressure measured in the morning is lolalively low, and gradually rises from afternoon to the night. Additionally, blood pressure is relatively low in summer, and relatively high in winter.
A j diffrernt times of a day, blood pressure change of the same people is also relotively rorpe, only the blood pressure measured at the same time of a day can be compared, ono more rational monitored blood pressure value can be obtained, mmHg
200 Change of blood pressure of adult in a day
150
100
75
50
Get up
7:00
Work
12:00
Get off Rest
18:00 24:00
Systolic pressure
Diastolic pressure
Classification of Blood Pressure by World Health Organization
[he World Health Organization (WHO) made classifications of blood pressure as shown in the following diagram.
This table displays blood pressure measurements of different people at different postures in hospital outpatient departments as the standard.
Notes:
Low blood pressure has no definition.
Generally people whose high pressure value is not up to 100mmHg (13.3kPa) are called hypotensive.
Systolic pressure
180
160
High 140 pressure
130
120
80 85 90 100 110
Low pressure
Ideal blood pressure
( target value)
Display mode: LCD digital display screen
• Measuring mode: depressurization type oscillometric method for measurement
• Power supply: 800mAh lithium battery
Measurement range: (0-280)mmHg/(0-37.3)kPa(blood
(40-195)times/min(pulse rate) pressure)
• Accuracy: ±3mmHg/±0.4kPa(blood pressure); ±5%(pulse rate)
• Air charging mode: automatic charging
• Air leakage device: air relief valve
• Quick air leakage: electronic air release valve
• Result display: high pressure/low pressure/pulse
• Unit conversion: conversion of blood pressure value unit mmHg/kPa
(default unit when start is mmHg)
• Number of memory groups: Double 99 memory groups
• Low battery inspection: LCD displays symbol' QZJ' to indicate low battery
• WHO tip: blood pressure warning strip is used to indicate blood pressure and health status, see table 2 for details
• Error tip: see table 1 for details
• Alillylhmia tip: LCD displays' • 'flickering to indicate arrhythmia
• Alilomatic shutdown function: outomatic shutdown in one minute when
11,0,8 is no operation
• W,
1I king conditions:
I I)
I nvirorimerit temperature: 5-40 degrees celsius;
I,) I<olalive humidity: lS%-80%RH;
, ) Almospheric pressure: 80kPa -lOSkPa.
Aesfee International Limited
Add:5/F,Building A,Longcheng Industrial Zone,No.39
Longguan
West Road,Longhua District,Shenzhen,518000,China [email protected]
Made in China