EMX Industries, Inc. BPE-50 Operating Instructions
EMX Industries, Inc. BPE-50 is a photo beam system that can be used for a variety of purposes, such as:
- Security: The BPE-50 can be used to detect intruders by breaking the beam between the transmitter and receiver.
- Automation: The BPE-50 can be used to trigger other devices, such as lights or motors, when the beam is broken.
- Measurement: The BPE-50 can be used to measure the distance between the transmitter and receiver, or to detect the presence of objects in the beam path.
The BPE-50 is a versatile and reliable device that can be used in a variety of applications.
Advertisement
Advertisement
B P E 5 0
™
Photo Beam with battery
powered Transmitter
Not UL325 compliant
Operating Instructions
This product is an accessory or part of a system.
Always read and follow the manufacturer’s instructions for the equipment you are connecting this product to. Comply with all applicable codes and safety regulations. Failure to do so may result in damage, injury or death!
Product Overview
The BPE-50 photo beam system uses 12 -24 VDC/AC on the transmitter and receiver with the transmitter offering the option of using the two 3.6 Volt batteries for power
(included). Recommended battery replacement is the Varta
ERAA 3V6 2400 .
WARNING …
Not to be used for Personnel Protection
Never use product as sensing devices for personnel protection.
Doing so could cause serious injury or death.
These sensors do NOT include the self-checking redundant circuitry necessary to allow their use in personnel safety applications. A sensor failure or malfunction can cause either an energized or de-energized sensor output condition. UL 325 Non-compliant
Technical Specifications
Power Supply 12-24 VDC 24 VAC (2-3.6 Volt Lithium
Current Draw
Relay Type
Batteries for transmitter optional
/included)
Expected battery life up to 2 years approx.
RX = <50mA standby 100mA activated, TX
= < 500uA
2 Form C DPST contact rating .5A @ 24VDC
/ 120VAC
Wavelength
Frequency
880 nm
High 90 Hz Low 48 Hz (Ext power 787 Hz)
Environmental IP 65
Detect Indicator Red LED
Connector
Relay contact
Terminal block
0.5Amp
Housing Material PA6 30% FG
Size H 4.4in (112mm) x W 2.05in (52mm) x D
1.3in (33mm)
Range Up to 50 feet (if TX on 12/24 V 90 feet)
Detection Angle +/- 5%
Sensitivity Jumper J1 on receiver
Detection delay < 30 ms
Reset delay < 120 ms
Connections
(Fig 1)
1
Transmitter
Power Positive (+)
2 Power Negative (-)
3 NC Security Contact
4
5
Receiver
Power Positive (+)
Power Negative (-)
Internal Relay
(join if not used)
Security edge
(join if not used)
Normally Open
Internal Relay
Common
Security edge
(join if not used)
Internal Relay
Normally Closed Output
Terminal connection as viewed from the front, left to right
Jumper Configuration
(Fig 2)
Jumper
Receiver J1 (Gain)
Transmitter J2
(frequency)
ON
Normal
Fast
Transmitter J3 (Security edge)
Not connected
Jumper Settings for figure 2
OFF
High
Slow
Connected
When transmitter frequency is set to low battery life will be increased. The range will be reduced at this setting. However when the transmitter is powered by 12/24 VDC or 24 VAC the range will be maximum regardless of the jumper setting.
Lens Alignment
(Fig 3)
Both the transmitter and receiver lenses may be aligned left, right or straight ahead. To align gently pull the lens stem straight out from mounting position and snap back into place pointing in the desired direction.
Units should be placed a minimum of 12 – 16 inches from the floor. Across from and lenses facing each other. The receiver red detect LED will be on when the beam is broken or not aligned.
Note: Rain, dust, fog, excess light or other adverse conditions may reduce the maximum range.
4564 Johnston Parkway
Cleveland, Ohio 44128
United States of America
WEB http://www.emxinc.com
Technical Support Telephone (216) 834-0761
E-mail [email protected]
Sales Telephone (216) 518-9888
Fax (216) 518-9884
Email [email protected]
BPE-50 Instructions rev 1.2 06/20/2013
Installation
(Fig 4)
Place the BPE-50 away from heat and electromagnetic sources for best operation. Mount units a minimum of
12 inches 30 cm from the floor.
Apply power to the units and set jumpers per instruction on see figures 1 and 2.
Test installation to insure desired and proper operation.
All local and operator manufacturer installation instructions should be followed.
The BPE-50 transmitter may be hooked up to an edge sensor for alternative activation operation.
The BPE-50 does not require any special care, but it is necessary to check condition occasionally to insure they are operating correctly. (Batteries are still operational if on battery power)
Recommended battery replacement is the Varta ERAA 3V6
2400 .