EcoFasten Clickfit Manual
EcoFasten Clickfit is a high-quality solar mounting system designed for shingle and tile roofs. It offers a rapid installation process, thanks to its innovative click-connector technology that eliminates the need for tools. The system is adjustable, allowing for easy leveling on uneven roof surfaces. EcoFasten Clickfit is compatible with a wide range of PV modules and is certified to withstand various weather conditions, ensuring the longevity of your solar investment.
Advertisement
Advertisement
RAPID
INSTALLATION,
HIGH-QUALITY SOLAR
MOUNTING SYSTEM
FOR SHINGLE AND
TILE ROOFS
VERSION: 2.0
TABLE OF CONTENTS
Subject Page #
Introduction 3
Product Description 4
Ratings 5
System Components
Required Tools
Array Layout
Installing ClickFit
8
9
6
7
Flashing and L feet
Installing Tile Hooks
Tile Hook Sub-Flashing
Installing the Rail
10
11
12
13
Module Installation
Bonding and Grounding
MLPE Clip Intallation
UL2703 Certified Modules
Clamp Tables
14 - 17
18 - 19
20
21-29
30
2
REV DATE: 07/16/2020
INTRODUCTION
1.0 Introduction
This manual describes the installation of the ClickFit mounting system for photovoltaic modules on steepslope roofs. Described within are details for composition shingle and tile, attachments for ClickFit for other roof types are available at www.EcoFastenSolar.com.
All installation manuals are available for download at www.EcoFastenSolar.com.
2.0 General Installation Conditions
2.1 General
Failure to observe the requirements in this document can lead to the exclusion of all guarantees and product liability. EcoFasten Solar reserves the right to amend this document without prior notice.
2.2 Stability and Condition of the Roof
The roof must be in good condition and strong enough to support the weight of the modules, including the additional equipment, wind and snow loads. When in doubt, consult with the engineer of record, and/or the local building inspector.
2.3 Application Range of ClickFit
• Refer to Compatibility module list on page 21.
• Please refer to the Ecofasten ClickFit span tables for system structural certification and allowable spans.
2.4 Warranty
Guarantee according to the warranty conditions and general terms and conditions of EcoFasten Solar. These conditions can be found on the website at www.EcoFastenSolar.com.
2.5 Liability
EcoFasten Solar cannot accept any liability whatsoever for damage or injury caused by not taking adequate safety precautions or (accurately) following the instructions given, or resulting from negligence during the installation of the product and any corresponding accessories specified in this document.
*Printing errors reserved
VERSION: 2.0
3
REV DATE: 07/16/2020
PRODUCT DESCRIPTION
The ClickFit mounting system consists of patented adjustable tile hooks and L feet, rails, and the installation materials required for the mounting of photovoltaic modules on composition shingle or tile roofs. For simplicity, tile hooks and L feet will be referred to as
“attachments”.
3.1 Attaching to the Roof
The attachments are fastened to the rafters. Attachments are height-adjustable to level the system on uneven roof surfaces.
3.2 Attaching the Rail
The rail assembles to the attachments with a click-connector, or Clicker. The rail simply clicks into place without the use of any tools.
3.3 Attaching the modules
The modules are attached to the rails by means of mid clamps and end clamps.
Installer must review the module manufacturer’s installation manual to confirm compliance to the warranty terms and conditions.
VERSION: 2.0
4
REV DATE: 07/16/2020
RATINGS
Fire Rating**
Max System Voltage
Max Fuse Rating
Certification
Warranty
UL 2703 Markings
Roof Pitch
UL 2703 Allowable Design Load Rating
Max Module Size
Module Orientation:
Class A System Fire Rating
1500 VDC
30A
Conforms to UL STD 2703
20 Year Material and Workmanship
Product listing label is located on the rail end-caps
2:12 – 12:12
10 psf downward, 5 psf upward, and 5 psf lateral
24 sqft
Portrait or Landscape
**Class A System fire rating with Type 1 & 2 PV modules. Any module-to-roof gap is permitted, with no skirt required. This rating is applicable with any roof attachment.
NOTE: Mid Clamp, MLPE Clip, and MLPE Bracket have been evaluated for multiple use, position independent.
UL 2703 Marking Example:
TM
CLICKFIT
SYSTEM
MFG ID CODE: XXX-MM-YYYY
1234567
Conforms to UL STD 2703
Torque Specifications
Lag Screw
Component
Mid-Clamp
End-Clamp
Rail Clicker Leveling Bolt
Hook Height Bolt
Ground Lug
MLPE Clip
MLPE Mount
Torque (in-lb)
N/A
144
96
142
N/A
N/A
144
144
Notes
Fully Seat. Use visual indicator of the black EPDM ring around the bonded washer for torquing.
Pre-torqued upon delivery. Applies to Tile Hook and L-Foot/Clicker
Lightly clamp hook to flush with top of next tile row
Refer to specific ground lug manufacturer’s installation manual
VERSION: 2.0
5
REV DATE: 07/16/2020
VERSION: 2.0
SYSTEM COMPONENTS
1) ClickFit Rail
1500033 (2130mm)
1500034 (3166mm)
1500035 (4202mm)
2) Rail Splice
1008061
3) CF Tile Hook and L foot
1500005 - Tile Hook
1500004 - L foot
4) CF End Clamp
See Section 10
5) CF End Cap
1510041 (Black)
1510042 (Grey)
6) CF Mid Clamp
See Section 10
7) MLPE Mount
1510057
8) MLPE Clip (RockIt Clip 2.0)
9) Module Jumper
1500028
6
REV DATE: 07/16/2020
REQUIRED TOOLS
Checklist of tools and accessories
Note: *Proper PPE shall be worn at all times*
VERSION: 2.0
Tape measure
Roof crayon or chalk (a chalk line can be helpful as well)
Cordless drill with torque adjustment and the following bits:
• 1/2” Hex socket
• 1/4” diameter drill bit. (Drilling length no less than lag bolt depth)
Brush for clearing debris from roof surface. Hint: Leaf blowers work well to remove any leftover moisture prior to installation.
Torque wrench capable of 0-150 in-lbs
7
REV DATE: 07/16/2020
ARRAY LAYOUT
• Refer to span tables, local jurisdiction, or engineer of record specifications when determining setbacks from roof edges, attachment spans, etc.
• Mark the perimeter and corners of the array on the roof surface.
*Add 3/4” to account for the gap between modules in each direction*
• Draw or snap chalk lines where the rails will be installed,(refer to module manufacturer specs to determine allowable mounting locations).
• Locate rafters within the area of the array. It may be necessary to shift the array East or West on the roof in order to fall within the rail cantilever specs (l/3) of span).
• Stagger rafters every row if required by the local jurisdiction, engineer of record, or company policy.
VERSION: 2.0
8
REV DATE: 07/16/2020
INSTALLING CLICKFIT
Pre-installing rail splices
1. Determine the number of rails required per row of modules.
2. Insert a rail splice into one rail. *Do not push it past the center bump.*
3. Slide the next rail onto the rail splice until the two rail ends meet.
4. Repeat steps 2 and 3 until the desired length is achieved. *This is usually easiest to do from the ground.*
VERSION: 2.0
9
REV DATE: 07/16/2020
FLASHING AND L FEET
Installation of flashing and L feet
• ClickFit for comp shingle roofs uses EcoFasten Solar’s GFl watertight flashing system
• Other roof types may use different EcoFasten Solar attachments, see www.EcoFastenSolar.com for more information.
Installation Steps:
1. Locate rafter lines from section 5.2.
2. Drill l/4” pilot holes at all attachment points and back fill using roof-compatible sealant.
3. Separate shingles where flashing is to be installed. Insert the flashing so the top portion is under the next row of shingles North. Ensure the flashing is pushed to the third-course of shingle to prevent water infiltration through the vertical joints between shingles.
4. Align GFl flashing hole with pilot hole. Insert the lag bolt with pre-installed bonded washer through the L foot and EPDM grommet. Tighten the lag bolt until a ring of EPDM is visible around the circumference of the bonded washer.
Tighten the lag until fully seated. The EPDM Ring visual indicator is the most effective way to ensure a watertight seal.
VERSION: 2.0
*Note the orientation of the L foot and Clicker. The two
Clicker “arms” should be facing downslope*
10
REV DATE: 07/16/2020
INSTALLING TILE HOOKS
1. Locate rafters on the roof, mark the tiles to be removed. Hint: In some cases rafter tails are visible at the eaves of the roof, making it easy to find the rough location of the rafters. In other cases, the fascia board may have nail heads visible where it was attached to the rafters. In the worst-case a row of tiles may need to be moved to determine the rafter locations.
2. Slide the tile at the desired location upward to expose the roof sub surface. If the tile is to be notched, or if using a replacement flashing, remove it entirely. Clean the sub surface with a brush to remove any debris that could affect the sealing.
3. Locate the rafter center and mark it.
4. Place the tile hook with the hook itself in the valley of the next tile below. Drill one l/4” pilot hole in the rafter center, taking care to keep the hook in the valley of the tile below. Backfill this hole with a roof- compatible sealant. For flat tiles, try to avoid having the hook land directly under a joint between tiles, this will create a larger gap or more notching than necessary.
5. Install one 5/16” x 4” lag screw on the row of holes closest to the tile hook arm. If possible, install the screw in one of the three holes directly next to the arm. If the lag screw must be installed in one of the seven holes furthest from the arm (denoted by the red rectangle below), install three deck screws in the pattern shown by the green circles below.
6. Adjust the height of the tile hook as necessary using the bolt shown in the fourth image.
7. Flash the surrounding area and lag screw head with roof-compatible sealant as necessary. Refer to Tile
Hook Subflashing Installation guide on the next page.
8. Replace the tile that was moved and/or removed, or install the tile replacement flashing. If it is to be notched, mark the tile for notching. Notching can be done with a grinding wheel or by using a chisel.
5.
6.
VERSION: 2.0
11
REV DATE: 07/16/2020
TILE HOOK SUB-FLASHING
CLICKFIT TILE HOOK SUB-FLASHING INSTALLATION STEPS:
Tools Required: Caulking gun, roofing mastic applicator
Materials Required: Roofing mastic, reinforcing fabric, roof sealant
Apply a continuous line of the roofing manufacturer’s approved sealant on the underside of the ClickFit tile hook sub-flashing to form a U-shape around the raised edges.
Lower the sub-flashing over the tile hook base. It may be necessary to move adjacent tiles to easily lower the sub-flashing onto the roof deck.
Place the sub-flashing over the base of the tile hook so the flashing covers the entire base.
EcoFasten recommends following the TRI guidelines three-course sealing method. Start the three-course sealing method by applying a layer of roofing mastic over the edges of the tile hook sub-flashing.
Place strips of reinforcing fabric over mastic to cover approximately 2” from the edge of the sub-flashing in both directions. Place strips on the side first, then the top edge.
VERSION: 2.0
Apply a final layer of mastic to completely cover the reinforcing fabric. The flashing is now installed and sealed.
REV DATE: 07/16/2020
INSTALLING THE RAIL
1. Place the rail in the Clickers.
2. Ensure the rails extend a minimum of 2” past the last attachments in each row and that each rail is aligned with the next row North and/or South.
3. Roll the rail into each Clicker, an audible “click” should be heard. If attachments are extremely misaligned it may be necessary to loosen the leveling bolt, snap the Clicker onto the rail, then re-tighten the leveling bolt to 142 in-lbs.
4. Level the rail if necessary by loosening the bolt attaching the Clicker to the L foot or tile hook.
*Ensure the tab on the Clicker is aligned with the rail edge as shown below*
VERSION: 2.0
13
REV DATE: 07/16/2020
MODULE INSTALLATION
1. Install the end clamps on each rail on whatever end you are starting with.
• Snap the end clamp onto the rail.
• Slide the end cap onto the rail.
• Turn the leg of the end clamp around the cap.
2. Place the module on the rail.
*Ensure module junction box is up-slope.*
3. Slide the module to the end clamp and align it with the array corners. Tighten the end clamp to 96 in-lb.
VERSION: 2.0
14
REV DATE: 07/16/2020
MODULE INSTALLATION
6.6 Installing additional modules on the rail
1. Click a mid clamp onto each rail.
2. Slide the mid clamps until they are flush with the side of the existing module.
3. Place and slide the next module firmly against the mid clamps. Align the bottom edges of the modules. Tighten mid clamps to 144 in-lb.
VERSION: 2.0
15
REV DATE: 07/16/2020
MODULE INSTALLATION
6.7 INSTALLING END CLAMPS AT THE END OF A ROW
1. Install the last mid clamps in the row.
2. Measure the rails from the last mid clamp to the module width plus l”.
3. Cut the rails at this mark. There is some adjustment in the end cap/clamp so it does not need to be a perfect cut.
4. Install end clamps and end caps, tighten to 96 in-lb
Alternative method:
1. Install the last module in the row, tighten the mid clamps.
2. Using a circular saw with a metal blade, or carefully with a reciprocating saw, cut the rail approximately l” past the edge of the last module.
3. Install end clamps and end caps, tighten to 96 in-lb
VERSION: 2.0
16
REV DATE: 07/16/2020
MODULE INSTALLATION
6.8 Installing additional rows of modules
1. Place the first module of the next row against the end clamps.
2. Temporarily place a mid clamp in the N-S gap between rows of modules, slide the modules up to the mid clamp as shown below.
3. Once the modules are aligned tighten the end clamps.
4. Install Dynobond clip on the bottom lip of the module frames to bond rows together.
5. Repeat steps 6.5-6.7 until the array is complete.
VERSION: 2.0
17
REV DATE: 07/16/2020
BONDING AND GROUNDING
Bonding Paths
All bond paths are carried either module-to-module through the mid clamp, or module-to- module through the module jumper shown below (bond paths shown in green):
1 ground lug per continuous array
VERSION: 2.0
18
REV DATE: 07/16/2020
7.2 Grounding
GROUNDING LUG INSTALL
BONDING AND GROUNDING
Install ground lug on the module per ground lug and module manufacturer’s instructions
NECESSARY COMPONENTS:
On of the following ground lugs (or any UL 2703 compliant ground lug):
• BurndyCL50-1TN Ground Lug (UL 2703 - E3514343 / UL 467-E9999)
• ILSCO SGB-4 Ground Lug (UL 2703 - E354420 I UL 467 - E34440)
• ILSCOGBL-40BT(UL2703 - E354420 I UL467 - E34440l
• ILSCO GBL-4DBTH (UL 2703 - E354420 / UL 467 - E34440)
• ILSCO GBL-455 (UL 2703 - E354420 I UL 467 - E34440)
This system needs to be grounded in accordance with the National Electrical Code, ANSI/NFPA 70.
*Copper wire should not come in direct contact with aluminum at any point on the array*
7.3 MLPE Clip Installation (Optional)
VERSION: 2.0
INSTALL MLPE CLIP ACCESSORY
• Determine mounting location of the MLPE and MLPE Clip on the module frame. Take care not to block drainage holes on the frame.
• Push the nut/bolt of the MLPE Clip so the carriage bolt head is furthest away from the stainless plate.
• Slide the bolt shaft into the slot on the MLPE mounting flange.
• Place the assembly onto the module flange, MLPE mounting flange on the far face (upper side) of the module frame flange, stainless plate on the closer face
(bottom side) of the module frame flange.
• Hold the carriage bolt into the MLPE mounting flange slot with your finger, this will keep the carriage bolt from spinning in the slot. Tighten the nut to 144 in-lbs using a
1/2” hex socket.
MLPE CLIP IS COMPATIBLE WITH:
• Enphase Products: M250-72, 250-60, M215-60, C250-72, S230, S280, IQ
6, IQ 6+, IQ, IQ7, IQ 7A, IQ 7+, IQ 7X, Q Aggregator
• SolarEdge Products: P300, P320, P340, P370, P400, P405, P485, P505,
P600, P700, P730, P800p, P800s, P850, P860
• See page 21 for compatible module list with MLPE Clip
19
REV DATE: 07/16/2020
MLPE MOUNT INTALLATION
Lower the MLPE Mount to the rail
Tilt and hook the mount around the top “dog ear” of the rail
Set the MLPE Mount flush with the top of the rail
Slide the microinverter flange between the
MLPE Mount and the serrated bolt flange
Tighten the bolt to 144 in-lbs
Repeat this process for all other microinverter and/or optimizer installations
MLPE MOUNT IS COMPATIBLE WITH:
Enphase Products: M250-72, 250-60, M215-60, C250-72, S230, S280, IQ 6, IQ 6+, IQ, IQ7, IQ 7A, IQ 7+, IQ 7X, Q Aggregator
SolarEdge Products: P300, P320, P340, P370, P400, P405, P485, P505, P600, P700, P730, P800p, P800s, P850, P860
VERSION: 2.0
20
REV DATE: 07/16/2020
UL2703 CERTIFIED MODULES
8.2 COMPATIBLE MODULE LIST
This racking system may be used to ground and/or mount a PV module complying with UL 1703 or UL 61730 only when the specific module has been evaluated for grounding and/or mounting in compliance with the included instructions.
Unless otherwise noted, “xxx” refers to the module power rating and both black and silver frames are included in the certification.
Manufacturer
AMERISOLAR
APTOS SOLAR
ASTRONERGY
SOLAR
ASUN
AUXIN
AXITEC
List of UL2703 Approved Modules
AMERISOLAR MODULES WITH 35, 40 AND 50 MM FRAMES
AS-BYXXXZ
WHERE "B" CAN BE 5 OR 6; "Y" CAN BE M, P, M27, P27, M30, OR P30; AND
"Z" CAN BE BLANK, W OR WB
APTOS MODULES WITH 35 AND 40 MM FRAMES
DNA-YY-ZZ23-XXX
WHERE "YY" CAN BE 120 OR 144; AND "ZZ" CAN BE MF OR BF
ASTRONERGY MODULES WITH 30, 35, 40, AND 45 MM FRAMES
AASMBBYYC/ZZ-XXX
WHERE “AA” CAN BE CH OR A; "BB" CAN BE 60, 66, OR 72; “YY” CAN BE
BLANK, 10 OR 12; "C" CAN M, P, M(BL), M-HC, M(BL)-HC, P-HC, M(DG), OR
M(DGT); AND “ZZ” CAN BE BLANK, HV, F-B, OR F-BH
ASUN MODULES WITH 35 AND 40 MM FRAMES
ASUN-XXX-YYZZ-AA
WHERE "YY" CAN BE 60 OR 72; "ZZ" CAN BE M,OR MH5; AND "AA" CAN BE
BLANK OR BB
AUXIN MODULES WITH 40 MM FRAMES
AXN6Y6ZAXXX
WHERE “Y” CAN BE M OR P; “Z” CAN BE 08, 09, 10, 11, OR 12; AND “A” CAN
BE F OR T
AXITEC MODULES WITH 35 AND 40 MM FRAMES
AC-XXXY/AAZZB
WHERE “Y” CAN BE M, P OR MH; “AA” CAN BE BLANK, 125- OR 156-; “ZZ”
CAN BE 54, 60, 72, 120, OR 144; “B” CAN BE S, X, V, XV, OR MX
VERSION: 2.0
21
REV DATE: 07/16/2020
UL2703 CERTIFIED MODULES
BOVIET
BYD
CANADIAN
SOLAR
CERTAINTEED
CSUN
ECOSOLARGY
ET SOLAR
FLEX
BOVIET MODULES WITH 35 AND 40MM FRAMES
BVM66AAYY-XXXBB
WHERE “AA” CAN BE 9, 10 OR 12; “YY” IS M OR P; AND “BB” CAN BE BLANK
OR
BYD MODULES WITH 35 MM FRAMES
BYDXXXAY-ZZ
WHERE “A” CAN BE M6, P6, MH OR PH; “Y” CAN BE C OR K; AND “ZZ” CAN
BE 30 OR 36
CANADIAN SOLAR MODULES WITH 30, 35 AND 40 MM FRAMES
CSBY-XXXZ
WHERE “B” CAN BE 1, 3 OR 6; “Y” CAN BE H, K, P, U, V, W, OR X; AND “Z” CAN
BE M, P, MS, PX , M-SD, P-AG, P-SD, MB-AG, PB-AG, MS-AG, OR MS-SD
CERTAINTEED MODULES WITH 35 AND 40 FRAMES
CTXXXYZZ-AA
WHERE “Y” CAN BE M, P, OR HC; “ZZ” CAN BE 00,01, 10, OR 11; AND “AA”
CAN BE 01, 02, 03, OR 04
CSUN MODULES WITH 35 AND 40 MM FRAMES
YYXXX-ZZABB
WHERE “YY” IS CSUN OR SST; “ZZ” IS BLANK, 60, OR 72; AND “A” IS BLANK, P
OR M; “BB” IS BLANK, BB, BW, OR ROOF
ECOSOLARGY MODULES WITH 35, 40, AND 50 MM FRAMES
ECOXXXYZZA-BBD
WHERE “Y” CAN BE A, H, S, OR T; “ZZ” CAN BE 125 OR 156; “A” CAN BE M OR
P; “BB” CAN BE 60 OR 72; AND “D” CAN BE BLANK OR B
ET SOLAR MODULES WITH 35, 40, AND 50 MM FRAMES
ET-Y6ZZXXXAA
WHERE “Y” CAN BE P, L, OR M; “ZZ” CAN BE 60 OR 72; AND “AA” CAN BE WB,
WW, BB, WBG, WWG, WBAC, WBCO, WWCO, WWBCO OR BBAC
FLEX MODULES WITH 35, 40, AND 50 MM FRAMES
FXS-XXXYY-ZZ;
WHERE “YY” CAN BE BB OR BC; AND “ZZ” CAN BE MAA1B, MAA1W, MAB1W,
SAA1B, SAA1W, SAC1B, SAC1W, SAD1W, SBA1B, SBA1W, SBC1B, OR SBC1W
VERSION: 2.0
22
REV DATE: 07/16/2020
UL2703 CERTIFIED MODULES
GCL
GIGAWATT
SOLAR
HANSOL
HANWHA SO-
LAR
HANWHA Q
CELLS
HELIENE
GCL MODULES WITH 35 MM AND 40 MM FRAMES
GCL-AB/YY XXX
WHERE “A” CAN BE M OR P; “B” CAN BE 3 OR 6; AND “YY” CAN BE 60, 72,
72H, OR 72DH
GIGAWATT MODULES WITH 40 MM FRAMES
GWXXXYY
WHERE “YY” CAN BE EITHER PB OR MB
HANSOL MODULES WITH 35 AND 40 FRAMES
HSXXXYY-ZZ
WHERE “YY” CAN BE PB, PD, PE, TB, TD, UB, UD, OR UE; AND “ZZ” CAN BE
AH2, AN1, AN3, AN4, HV1, OR JH2
HANWHA SOLAR MODULES WITH 40, 45, AND 50 MM FRAMES
HSLAAP6-YY-1-XXXZ
WHERE “AA” CAN BE EITHER 60 OR 72; “YY” CAN BE PA OR PB; AND “Z” CAN
BE BLANK OR B
HANWHA Q CELLS MODULES WITH 32, 35, 40, AND 42MM FRAMES
AAYY-ZZ-XXX
WHERE “AA” CAN BE Q. OR B.; “YY” CAN BE PLUS, PRO, PEAK, LINE PRO,
LINE PLUS, PLUS DUO OR PEAK DUO; AND “ZZ” CAN BE G3, G3.1, G4, G4.1,
L-G2, L-G2.3, L-G3, L-G3.1, L-G3Y, L-G4, L-G4.2, L-G4Y, LG4.2/TAA, BFR-G3,
BLK-G3, BFR-G3.1, BLK-G3.1, BFR-G4, BFR-G4.1, BFR G4.3, BLK-G4.1, G4/SC,
G4.1/SC, G4.1/TAA, G4.1/MAX, BFR G4.1/TAA, BFR G4.1/MAX, BLK G4.1/TAA,
BLK G4.1/SC, EC-G4.4, G5, G5/SC, BLK-G5, BLK-G5/SC, L-G5, L-G5.1, L-G5.2,
L-G5.2/H, L-G5.3, G6, G6/SC, G6+, BLK-G6, L-G6, L-G6.1, L-G6.2, L-G6.3,
G7, BLK-G6+, BLK-G6+/AC, BLK-G6+/SC, BLK-G7, G7.2, G8, BLK-G8, G8+,
BLK-G8+ L-G7, L-G7.1, L-G7.2, L-G7.3, L-G8, L-G8.1, L-G8.2, L-G8.3, L-G8.3/
BFF, L-G8.3/BFG, ML-G9 OR XL-G9.3
HELIENE MODULES WITH 40 MM FRAMES
YYZZXXXA
WHERE “YY” CAN BE 36, 60, 72, OR 96; “ZZ” CAN BE M, P, OR MBLK; AND “A”
CAN BE BLANK, HOMEPV, OR BIFACIAL
VERSION: 2.0
23
REV DATE: 07/16/2020
UL2703 CERTIFIED MODULES
HT-SAAE
HYUNDAI
ITEK
JA SOLAR
JINKO
KYOCERA
LG
HT-SAAE MODULES WITH 35 AND 40 MM FRAMES
HTYY-156Z-XXX
WHERE “YY” CAN BE 60 OR 72, “Z” CAN BE M, P, M-C, P-C, M(S), M(VS), M(V),
P(V), M(V)-C, P(V)-C
HYUNDAI MODULES WITH 33, 35, 40 AND 50 MM FRAMES
HIY-SXXXZZ
WHERE “Y” CAN BE A, D, M OR S; AND “ZZ” CAN BE HG, HI, KI, MI, MF, MG, RI,
RG, RG(BF), RG(BK), SG, TI, OR TG
ITEK MODULES WITH 40 AND 50 MM FRAMES
IT-XXX-YY
WHERE “YY” CAN BE BLANK, HE, OR SE, OR SE72
JA SOLAR MODULES WITH 30, 35, 40 AND 45 MM FRAMES
JAYYZZ-BBWW-XXX/AA
WHERE “YY” CAN BE M, P, M6 OR P6; “ZZ” CAN BE BLANK, (K), (L), (R), (V),
(BK), (FA), (TG), (FA)(R), (L)(BK), (L)(TG), (R)(BK), (R)(TG), (V)(BK), (BK)(TG), OR
(L)(BK)(TG); “BB” CAN BE 48, 60, OR 72; “WW” CAN BE D09, S01, S02, S03,
S06, S09, S10, OR S12; AND “AA” CAN BE BP, MP, SI, SC, PR, 3BB, 4BB, 4BB/
RE, 5BB
JINKO MODULES WITH 35 AND 40 MM FRAMES
JKMYXXXZZ-AA
WHERE “Y” CAN EITHER BE BLANK OR S; “ZZ” CAN BE M, P, OR PP; AND “AA”
CAN BE BLANK, 60, 60B, 60H, 60L, 60BL, 60HL, 60HB, 60HBL, 6HBL-EP, 60-
J4, 60B-J4, 60B-EP, 60(PLUS), 60-V, 60-MX, 72, 72-V, 72H-V, 72L-V, 72HL-V,
72-MX, 72H-BDVP, 72HL-TV, OR 72HL-V-MX3
KYOCERA MODULES WITH 46MM FRAMES
KYXXXZZ-AA
WHERE “Y” CAN BE D OR U; “ZZ” CAN BE BLANK, GX, OR SX; AND “AA” CAN
BE LPU, LFU, UPU, LPS, LPB, LFB, LFBS, LFB2, LPB2, 3AC, 3BC, 3FC, 4AC, 4BC,
4FC, 4UC, 5AC, 5BC, 5FC, 5UC, 6BC, 6FC, 8BC, 6MCA, OR 6MPA
LG MODULES WITH 35, 40, AND 46 MM FRAMES
LGXXXYAZ-BB
WHERE “Y” CAN BE A, E, N, Q, S; “A” CAN BE 1 OR 2; “Z” CAN BE C, K, T, OR
W; AND “BB” CAN BE A3, A5, B3, G3, G4, J5, K4, OR V5
VERSION: 2.0
24
REV DATE: 07/16/2020
UL2703 CERTIFIED MODULES
LONGI
MISSION SO-
LAR
MITSUBISHI
MOTECH
NEO SOLAR
POWER
PANASONIC
PEIMAR
PHILADELPHIA
SOLAR
PHONO SO-
LAR
LONGI MODULES WITH 30, 35 AND 40 MM FRAMES
LRA-YYZZ-XXXM
WHERE “A” CAN BE 4 OR 6; “YY” CAN BE BLANK, 60 OR 72; AND “ZZ” CAN BE
BLANK, BK, BP, HV, PB, PE, PH, HBD, HIB, HIH, HPB, HPH, OR HIBD
MISSION SOLAR MODULES WITH 33 AND 40 MM FRAMES
MSEBBXXXZZAA
WHERE “BB” CAN BE BLANK OR 60A; “ZZ” CAN BE BLANK, MM, SE, SO, SQ ,
SR, OR TS; AND “AA” CAN BE BLANK, 1J, 4J, 4S, 5K, 5T, 60, 6J, 6S, 6W, 8K, 8T,
OR 9S
MITSUBISHI MODULES WITH 46 MM FRAMES
PV-MYYXXXZZ
WHERE “YY” CAN BE LE OR JE; AND “ZZ” CAN BE EITHER HD, HD2, OR FB
IM AND XS SERIES MODULES WITH 40, 45, AND 50 MM FRAMES
NEO SOLAR POWER MODULES WITH 35 MM FRAMES
D6YXXXZZAA
WHERE “Y” CAN BE M OR P; “ZZ” CAN BE B3A, B4A, E3A, E4A, H3A, H4A; AND
“AA” CAN BE BLANK, (TF), ME OR ME (TF)
PANASONIC MODULES WITH 35 AND 40 MM FRAMES
VBHNXXXYYZZA
WHERE “YY” CAN BE EITHER KA, RA, SA OR ZA; “ZZ” CAN BE EITHER 01, 02,
03, 04, 06, 06B, 11, 11B, 15, 15B, 16, 16B, 17, OR 18; AND “A” CAN BE BLANK
E, G OR N
PEIMAR MODULES WITH 40 MM FRAMES
SBXXXYZZ
WHERE “B” CAN BE G, M OR P; “Y” CAN BE M OR P; AND “ZZ” CAN BE BLANK,
(BF), OR (FB)
PHILADELPHIA MODULES WITH 35 AND 40 MM FRAMES
PS-YZZAA-XXX
WHERE “Y” CAN BE M OR P; “ZZ” CAN BE 60 OR 72; AND “AA” CAN BE BLANK
OR (BF)
PHONO SOLAR MODULES WITH 35, 40, AND 45 MM FRAMES
PSXXXY-ZZ/A
WHERE “Y” CAN BE M, M1, MH, OR M1H OR P; “ZZ” CAN BE 20 OR 24; AND
“A” CAN BE F, T, U, OR TH
VERSION: 2.0
25
REV DATE: 07/16/2020
UL2703 CERTIFIED MODULES
RECOM
REC SOLAR
RENESOLA
RENOGY
RISEN
S-ENERGY
SERAPHIM EN-
ERGY GROUP
SERAPHIM
USA
SHARP
RECOM MODULES WITH 35 AND 40 MM FRAMES
RCM-XXX-6YY
WHERE “YY” CAN BE MA, OR MB, ME OR MF
REC MODULES WITH 30, 38 AND 45 MM FRAMES
RECXXXYYZZ
WHERE “YY” CAN BE AA, M, NP, PE, PE72, TP, TP2, TP2M, TP2SM, OR TP2S;
AND “ZZ” CAN BE BLANK, BLACK, BLK, BLK2, SLV, OR 72
RENESOLA MODULES WITH 35, 40 AND 50 MM FRAMES
AAXXXY-ZZ
WHERE “AA” CAN BE SPM(SLP) OR JC; “Y” CAN BE BLANK, F, M OR S; AND
“ZZ” CAN BE BLANK, AB, AB-B, ABH, ABH-B, ABV, ABV-B, BB, BB-B, BBH,
BBH-B, BBV, BBV-B, DB, DB-B, OR 24/BB
RENOGY MODULES WITH 40 AND 50 MM FRAMES
RNG-XXXY
WHERE “XXX” IS THE MODULE POWER RATING; AND “Y” CAN BE D OR P
RISEN MODULES WITH 35 AND 40 MM FRAMES
RSMYY-6-XXXZZ
WHERE “YY” CAN BE 60, 72, 120, 132 OR 144; AND “ZZ” CAN BE M OR P
S-ENERGY MODULES WITH 40 FRAMES
SNXXXY-ZZ
WHERE “Y” CAN BE M OR P; AND “ZZ” CAN BE 10, OR 15
SERAPHIM MODULES WITH 35 AND 40 MM FRAMES
SEG-AYY-XXXZZ
WHERE “A” CAN BE BLANK, 6 OR B; “YY” CAN BE BLANK, MA, MB, PA, OR PB;
AND “ZZ” CAN BE BLANK, BB, BG, BW, HV, WB, WW, BMB, BMB-HV
SERAPHIM MODULES WITH 40 AND 50 MM FRAMES
SRP-XXX-6YY-ZZ
WHERE “XXX” IS THE MODULE POWER RATING; AND “YY” CAN BE MA, MB,
PA, PB, QA-XX-XX, AND QB-XX-XX; ZZ IS BLANK, BB OR HV
SHARP MODULES WITH 35 AND 40 MM FRAMES
NUYYXXX
WHERE “YY” CAN BE SA OR SC
VERSION: 2.0
26
REV DATE: 07/16/2020
UL2703 CERTIFIED MODULES
SILFAB
SOLARIA
SOLARCITY
(TESLA)
SOLARTECH
SOLARWORLD
AG
SOLARWORLD
AMERICAS
SONALI
STION
SUNEDISON
SILFAB MODULES WITH 38 MM FRAMES
SYY-Z-XXXAB
WHERE “YY” CAN BE IL, SA, LA, SG OR LG; “Z” CAN BE BLANK, M, P, OR X; “A”
CAN BE BLANK, B, H, M, N; AND “B” CAN BE A, L, G, OR T
SOLARIA MODULES WITH 40 MM FRAMES
POWERXT XXXY-ZZ
WHERE “Y” CAN BE R OR C; AND “ZZ” CAN BE AC, BD, BX, BY, PD, PM, PM-AC,
PX, PZ, WX OR WZ
SOLARCITY MODULES WITH 40 MM FRAMES
SCXXXYY
WHERE “YY” CAN BE BLANK, B1 OR B2
SOLARTECH MODULES WITH 42 MM FRAMES
STU-XXXYY
WHERE “YY” CAN BE PERC OR HJT
SOLARWORLD SUNMODULE PLUS, PROTECT, BISUN, XL, BISUN XL, MAY BE
FOLLOWED BY MONO, POLY, DUO, BLACK, BK, OR CLEAR; MODULES WITH
31, 33 OR 46 MM FRAMES
SW-XXX
SOLARWORLD SUNMODULE PLUS, PROTECT, BISUN, XL, BISUN XL, MAY BE
FOLLOWED BY MONO, POLY, DUO, BLACK, BK, OR CLEAR; MODULES WITH
33 MM FRAMES
SWA-XXX
SONALI MODULES WITH 40 MM FRAMES
SSXXX
STION THIN FILM MODULES WITH 35 MM FRAMES
STO-XXX OR STO-XXXA
SUNEDISON MODULES WITH 35, 40 & 50 MM FRAMES
SE-YXXXZABCDE
WHERE “Y” CAN BE B, F, H, P, R, OR Z; “Z” CAN BE 0 OR 4; “A” CAN BE
B,C,D,E,H,I,J,K,L,M, OR N ; “B” CAN BE B OR W; “C” CAN BE A OR C; “D” CAN
BE 3, 7, 8, OR 9; AND “E” CAN BE 0, 1 OR 2
VERSION: 2.0
27
REV DATE: 07/16/2020
UL2703 CERTIFIED MODULES
SUNIVA
SUNPOWER
SUNSPARK
SUNTECH
TALESUN
TRINA
URE
SUNIVA MODULES WITH 35, 38, 40, 46, AND 50 MM FRAMES
OPTXXX-AA-B-YYY-Z
MVXXXX-AA-B-YYY-Z
WHERE “AA” IS EITHER 60 OR 72; “B” IS EITHER 4 OR 5; “YYY” IS EITHER
100,101,700,1B0, OR 1B1; AND “Z” IS BLANK OR B
SUNPOWER STANDARD (G3 OR G4) OR INVISIMOUNT (G5) 40 AND 46 MM
FRAMES
SPR-ZB-XXX-YY
WHERE “Z” IS EITHER A, E, P OR X; “B” CAN BE BLANK, 17, 18, 19, 20, 21, OR
22; AND “YY” CAN BE BLANK, BLK, COM, C-AC, D-AC, E-AC, G-AC, BLK-C-AC,
OR BLK-D-AC
SUNSPARK MODULES WITH 40 MM FRAMES
SYY-XXXZ
WHERE “YY” CAN BE MX OR ST; AND “Z” CAN BE M, P OR W
SUNTECH MODULES WITH 35, 40 AND 50MM FRAMES
STPXXXY-ZZ/AA
WHERE “Y” IS BLANK OR S; AND “ZZ” CAN BE 20, 24; AND “AA” CAN BE VD,
VEM, VFW, WDB, WDE OR WD
TALESUN MODULES WITH 35 AND 40 FRAMES
TP6YZZAAXXX-B
WHERE “YY” CAN BE BLANK, F OR H; “ZZ” CAN BE 60 OR 72; “AA” CAN BE M
OR P; AND “B” CAN BE BLANK, B, T, OR (H)
TRINA MODULES WITH 30, 35, 40 AND 46MM FRAMES
TSM-XXXYYZZ
WHERE “YY” CAN BE DD05, DD06, DD14, DE14, DE15, DEG15, PA05, PC05,
PD05, PD06, PA14, PC14, PD14, PE14, OR PE15 ; AND “ZZ” CAN BE BLANK,
.05, .08, .10, .18, .08D, .18D, 0.82, .002, .00S, 05S, 08S, A, A.05, A.08, A.10,
A.18, A(II), A.05(II), A.08(II), A.082(II), A.10(II), A.18(II), H, H(II), H.05(II), H.08(II),
HC.20(II), HC.20(II), M, M(II), M.05(II), MC.20(II)
URE MODULES WITH 35 MM FRAMES
DYZXXXHAA
WHERE “Y” CAN BE 6 OR 7; “Z” CAN BE K OR M; AND “AA” CAN BE H3A, H4A,
OR H8A
VERSION: 2.0
28
REV DATE: 07/16/2020
UL2703 CERTIFIED MODULES
VIKRAM
VSUN
WINAICO
YINGLI
ZNSHINE
VIKRAM SOLAR MODULES WITH 40 MM FRAMES
VSYY.ZZ.AAA.BB
WHERE “YY” CAN BE M, P, MBB, MH, MS, MHBB, OR PBB; “ZZ” CAN BE 60 OR
72; “AAA” IS THE MODULE POWER RATING; AND “BB” CAN BE 03.04 OR 05
VSUN MODULES WITH 35 AND 40 MM FRAMES
VSUNXXX-YYZ-AA
WHERE “YY” CAN BE 60, 72, 120, OR 144; “Z” CAN BE M, P, MH, PH, OR BMH;
AND “AA” CAN BE BLANK, BB, OR DG
WINAICO MODULES WITH 35 AND 40 MM FRAMES
WSY-XXXZA
WHERE “Y” CAN BE EITHER P OR T; “Z” CAN BE EITHER M, P, OR MX; AND “A”
CAN BE BLANK OR 6
PANDA, YGE, YGE-U, AND YLM SERIES MODULES WITH 35, 40, AND 50 MM
FRAMES
ZNSHINE MODULES WITH 30, 35, AND 40MM FRAMES
ZXY6-ZZAA-XXX/B
WHERE “Y” CAN BE M OR P; “ZZ” CAN BE BLANK, H, HLD, HLDD, LD, LDD,
NH, NHLD OR NHLDD; “AA” CAN BE 60, 72, 120 OR 144; AND “B” CAN BE M
OR P
VERSION: 2.0
29
REV DATE: 07/16/2020
CLAMP TABLES
Frame Thickness
30 mm
32 mm
35 mm
38 mm
40 mm
45 mm
50 mm
End Clamps
Article Number
1510015
1510016
1510017
1510018
1510019
1510020
1510021
Frame Thickness
30-40 mm
40-50 mm
Mid Clamps
Article Number
1510011
1510012
INSTALLER RESPONSIBILITIES
Periodic reinspection of components shall be performed to verify that there is no corrosion detrimental to system strength and electrical conductivity, no loose bolts, and/or other variables that could compromise array safety. Any corroded or damaged components shall be immediately replaced.
VERSION: 2.0
30
REV DATE: 07/16/2020