IEI Integration POCm-W24C-ULT3 24” Medical Panel PC ULT Core™ i7/i5/Celeron® processor Quick Installation Guide 20 Pages
IEI Integration POCm-W24C-ULT3 24” Medical Panel PC ULT Core™ i7/i5/Celeron® processor Quick Installation Guide
IEI Integration POCm-W22C-ULT3 is a medical-grade panel PC engineered for seamless integration into healthcare environments. Its advanced features empower healthcare professionals with exceptional capabilities. With a powerful 6th Gen Intel® Core™ processor, 4GB of DDR4 memory, and a range of connectivity options, the POCm-W22C-ULT3 delivers smooth data processing and efficient multitasking. The 21.5" LCD display with a resolution of 1920 x 1080 offers exceptional image quality for precise visualization of medical data. The intuitive P-CAP touchscreen provides a responsive and user-friendly interface, while the three hot-swappable battery bays ensure continuous operation even in demanding situations. With its robust design, IP65-compliant front panel, and fanless cooling system, the POCm-W22C-ULT3 is built to withstand the rigors of healthcare environments.
advertisement
Medical Panel PC with 6th Gen. Intel® Core™ / Celeron® CPU,
4 GB DDR4 RAM, Wi-Fi 802.11a/b/g/n/ac, P-CAP Touchscreen,
Three Battery Bays, 5-Megapixel Camera and Microphone
POCm-W22C-ULT3
POCm-W24C-ULT3
Quick Installation Guide
Version 1.01
©2018 Copyright by IEI Integration Corp.
All rights reserved.
Revision
Date
September 11, 2018
August 28, 2018
Intended Use
Version Changes
1.01 Minor update
1.00 Initial release
The POCm-W22/24C-ULT3 medical panel PC is intended to be used to display general purpose medical images. The device shall not be used for diagnosis purpose or life supporting system.
Equipment connected to analog or digital interfaces must comply with the respective
IEC Standards (e.g. IEC 60950 for data processing equipment and IEC 60601-1 for medical equipment). Furthermore all configurations shall comply with the current version of the standard for SYSTEMS IEC 60601-1-1. Everybody who connects additional equipment to the signal input part or signal output part configure a medical system, and is therefore responsible that the system complies with current version of the requirements of the system standard IEC 60601-1-1. If in doubt, consult the technical service department or your local representative.
Manual Conventions
WARNING
Warnings appear where overlooked details may cause damage to the equipment or result in personal injury. Warnings should be taken seriously.
CAUTION
Cautionary messages should be heeded to help reduce the chance of losing data or damaging the product.
NOTE
These messages inform the reader of essential but non-critical information. These messages should be read carefully as any directions or instructions contained therein can help avoid making mistakes.
OPERATING INSTRUCTION
Follow operating instructions or consult instructions for use.
IEC 60417-5009: Stand-by
IEC 60417-5031: Direct current
1
Overview
The POCm-W22/24C-ULT3 is a 6 th
generation Intel® Core™ i5-6300U processor powered medical-grade panel PC with a rich variety of functions and peripherals. All POCm-W22/24C-ULT3 models are designed for easy and simplified integration into point-of-care (POC) applications. The system comes with 4 GB of preinstalled DDR4 memory and supports a maximum of 32 GB ensuring smooth data throughputs with reduced bottlenecks and fast system access.
Two RS-232/422/485 serial ports, four USB 3.0 ports and two USB 2.0 ports provide simplified connectivity to a variety of external peripheral devices. Wi-Fi 802.11a/b/g/n/ac high speed wireless and two RJ-45 GbE connectors allow for smooth connection of the system to an external LAN.
Three hot-swappable battery bays allow installation of three batteries to provide continuous power for 8~16 hours.
2
Front Panel
Bottom Panel
3
Side Panel
Rear Panel
4
System Specifications
LCD and Touchscreen
LCD Size
Max. Resolution
Brightness (cd/m2)
Contrast Ratio
LCD Color
Pixel Pitch (mm)
Viewing Angle (H-V)
Backlight MTBF
Touchscreen
Multi-touch
Touch Controller
Surface Hardness
System
CPU
POCm-W22C-ULT3 POCm-W24C-ULT3
21.5" (16:9) 23.8" (16:9)
1920 (W) x 1080 (H)
250
1000:1
16.7M (RGB 6-bit)
1920 (W) x 1080 (H)
250
1000:1
16.7M (RGB 6-bit + Hi-FRC)
0.24825 (H) x 0. 24825 (V) 0.2745 (H) x 0. 2745 (V)
170°/160° 178°/178°
30,000 hrs (LED backlight) 30,000 hrs (LED backlight)
Projected capacitive type with USB interface
10-point touch
EETI
6H
Memory
GbE Controller
I/O Ports
Storage
Audio
Webcam & Microphone
Expansion Interface
Intel® Celeron® 3855U / Intel® Core™ i5-6300U /
Intel® Core™ i7-6600U
Two 260-pin 2133/1866 MHz dual-channel non-ECC unbuffered DDR4 SO-DIMMs supported (system max.
32 GB)
Preinstalled with 4 GB memory
LAN1: Intel I211 Ethernet controller
LAN2: Intel® I219 Ethernet controller
1 x DC input jack
2 x HDMI output connector
2 x GbE LAN (RJ-45 connector)
2 x RS-232/422/485 serial port (DB-9 connector)
4 x USB 3.0 connectors
2 x USB 2.0 connectors (side panel)
1 x Audio out (side panel)
1 x Mic-in (side panel)
1 x Digital microphone
One 2.5” SATA 6Gb/s HDD bay
Two 3 W speakers
5-megapixel CMOS front-facing camera with auto focus and digital microphone
2 x M.2 M-key 2242/2260/2280 slot (PCIe + SATA) with
RAID
1 x M.2 A-/E-key 2242 slot (PCIe + USB)
1 x Full-size/Half-size PCIe Mini (PCIe + USB)
5
TPM
Other Features
Function Keys
LED Indicators
TPM 2.0 (optional)
1 x Power on/off
1 x Brightness up
1 x Brightness down
1 x Volume up
1 x Volume down
1 x Touch lock (clean mode) or LCD on/off
3 x Battery indicator
1 x Power indicator
Fanless Cooling Method
Connectivity
Wi-Fi and Bluetooth
LAN
Physical
Construction Material
Mounting
802.11a/b/g/n/ac dual band, Bluetooth v4.2
(M.2 2230 module, Intel® 8265)
Two GbE LAN connectors
PC+ABS plastic with anti-bacterial material
Wall and stand mounting
VESA 75 mm x 75 mm or 100 mm x 100 mm
Dimensions (W x H x D) 543 x 350 x 71 (mm)
Net Weight
Environment
7.07 kg
594.6 x 379.6 x 71 (mm)
8.18 kg
Storage/Transportation
Temperature
Humidity
Pressure
Temperature
-20ºC ~ 60ºC
10% ~ 90% (non-condensing)
700 hPa ~ 1060 hPa
0ºC ~ 40ºC
Operating
Vibration
Shock
IP Level
Power
Power Input
Humidity
Pressure
10% ~ 90% (non-condensing)
700 hPa ~ 1060 hPa
1G
Operating Shock: 5G peak acceleration (11ms duration)
Non-Operating Shock: 10G peak acceleration (11ms duration)
IP 65 compliant front panel
Power Adapter
Battery
19 V DC
150 W FSP FSP150M-ABA medical-grade power adapter
(P/N: 63040-010150-400-RS)
Input: 100 V AC ~ 240 V AC, 50 Hz ~ 60 Hz, 2A ~ 0.85A
Output: 19 V 7.89 A
3 x Hot-swappable battery bay
6
Installation Precautions
When installing the medical panel PC, please follow the precautions listed below:
Manufacturer authorization : Do not modify this equipment without authorization of manufacturer.
Certified Engineers : Only certified engineers should install and modify the hardware settings.
Power turned off : When installing the medical panel PC, make sure the power is off. Failing to turn off the power may cause severe injury to the body and/or damage to the system.
Anti-static Discharge : If a user open the rear panel of the medical panel PC, to configure the jumpers or plug in added peripheral devices, ground themselves first and wear an anti-static wristband.
WARNING:
Danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type recommended by the manufacturer.
Disposal of a battery into fire or a hot oven, or mechanically crushing or cutting of a battery, that can result in an explosion.
Leaving a battery in an extremely high temperature surrounding environment that can result in an explosion or the leakage of flammable liquid or gas.
A battery subjected to extremely low air pressure that may result in an explosion or the leakage of flammable liquid or gas.
7
Mounting the System
WARNING:
Use suitable mounting apparatus and be sure to secure the screws of the mounting apparatus tightly to avoid risk of injury.
NOTE:
When mounting the POCm-W22/24C-ULT3 flat panel PC, it is better to have more than one person to help with the installation to make sure the
POCm-W22/24C-ULT3 does not fall down and get damaged.
The POCm-W22/24C-ULT3 is VESA (Video Electronics Standards
Association) compliant and can be mounted on a mounting device with a 75 mm or 100 mm interface pad. The POCm-W22/24C-ULT3 VESA mount retention screw holes are shown below. Refer to the installation guide that came with the mounting device to mount the POCm-W22/24C-ULT3.
8
Powering On the System
WARNING:
To avoid risk of electric shock, this equipment must only be connected to supply mains with protective earth.
CAUTION:
The FSP FSP150M-ABA power adapter came with the
POCm-W22/24C-ULT3 is a forming part of the medical device.
Step 1: Connect the power cord to the power adapter. Connect the other end of the power cord to a power source.
Step 2: Connect the power adapter to the power connector of the
POCm-W22/24C-ULT3.
Step 3: Locate the power button on the right panel.
Step 4: Short press the power button to turn on the POCm-W22/24C-ULT3.
Shutdown Procedure
Turn off the power and disconnect the power cord.
To prevent the risk of electric shock, make sure power cord is unplugged from wall socket. To fully disengage the power to the unit, please disconnect the power cord from the AC outlet. Refer servicing to qualified service personnel. The AC outlet shall be readily available and accessible.
9
Troubleshooting
If the following situations happen, contact your distributor, sales representatives or IEI customer service center for technical support.
The HDD is installed correctly, but the POCm-W22/24C-ULT3 is unable to boot with AC power input after pressing the power button.
Unable to shut down the POCm-W22/24C-ULT3 normally
Please have the following information prepared prior to reporting the abnormal situations:
Product name and S/N
OS, BIOS version and applications
A complete description of the abnormal situation (with photos or video if available)
System Maintenance
If the components of the POCm-W22/24C-ULT3 fail they must be replaced.
Please contact the system reseller or vendor to purchase the replacement parts.
Maintenance and Cleaning
Prior to cleaning any part or component of the POCm-W22/24C-ULT3, please read the details below.
To clean the POCm-W22/24C-ULT3, o remove dirt with a lightly moistened cloth. Then wipe the external chassis with a soft dry cloth. o use 75% ethanol alcohol to clean the external chassis.
Cleaning frequency: follow the cleaning method guidelines of the hospital.
Except for the LCD panel, never spray or squirt liquids directly onto any other components.
The interior of the POCm-W22/24C-ULT3 does not require cleaning.
Keep fluids away from the POCm-W22/24C-ULT3 interior.
Never drop any objects or liquids through the openings of the
POCm-W22/24C-ULT3.
10
Accessories
The medical panel PC is shipped with the following components:
Quantity Item Image
1
POCm-W22/24C-ULT3 medical panel
PC
1
1
4
Power cord
( P/N : 32702-000200-100-RS)
150 W FSP FSP150M-ABA medical-grade power adapter
( P/N : 63040-010150-400-RS)
Round-head screw (M3*3) for HDD installation
( P/N : 44003-030032-RS)
1 Quick Installation Guide
Optional Items
The following components may be separately purchased:
Item and Part Number Image
Li-ion battery pack, 7800 mAh
( P/N : 31603-000069-RS)
Cable cover
( P/N : 43106-0272Q7-00-RS)
20-pin Infineon TPM 2.0 module, software management tool, firmware v5.5
( P/N : TPM-IN02-R20)
11
DECLARATION OF CONFORMITY
This equipment is in conformity with the following EU directives:
EMC Directive (2004/108/EC, 2014/30/EU)
Low-Voltage Directive (2006/95/EC, 2014/35/EU)
RoHS II Directive (2011/65/EU, 2015/863/EU)
Medical Device Directive 93/42/EEC: EN 60601-1
If the user modifies and/or install other devices in the equipment, the CE conformity declaration may no longer apply.
If this equipment has telecommunications functionality, it also complies with the requirements of the Radio Equipment Directive 2014/53/EU.
IEI Integration Corp declares that this equipment is in compliance with the essential requirements and other relevant provisions of Directive
2014/53/EU.
FCC WARNING
This equipment complies with part 18 of the FCC Rules.
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
12
ROHS STATEMENT
The label on the product indicates this product conforms to European
(EU) Restriction of Hazardous Substances (RoHS) that set maximum concentration limits on hazardous materials used in electrical and electronic equipment.
CHINA ROHS
The label on the product indicates the estimated “Environmentally
Friendly Use Period” (EFUP). This is an estimate of the number of years that these substances would “not leak out or undergo abrupt change.”
This product may contain replaceable sub-assemblies/components which have a shorter EFUP such as batteries and lamps. These components will be separately marked.
13
Safety Precautions
WARNING:
The precautions outlined below should be strictly followed. Failure to follow these precautions may result in permanent damage to the
POCm-W22/24C-ULT3 .
General Safety Precautions
Please ensure the following safety precautions are adhered to at all times.
To prevent the risk of electric shock, make sure power cord is unplugged from wall socket. To fully disengage the power to the unit, please disconnect the power cord from the ac outlet. Refer servicing to qualified service personnel. The AC outlet shall be readily available and accessible.
Users must not allow SIP/SOPs and the patient to come into contact at the same time.
Grounding reliability can only be achieved when the equipment is connected to an equivalent receptacle marked “Hospital Only” or
“Hospital Grade”.
Follow the electrostatic precautions outlined below whenever the
POCm-W22/24C-ULT3 is opened.
Make sure the power is turned off and the power cord is disconnected whenever the POCm-W22/24C-ULT3 is being installed, moved or modified.
Do not apply voltage levels that exceed the specified voltage range.
Doing so may cause fire and/or an electrical shock. Use a power cord that matches the voltage of the power outlet, which has been approved and complies with the safety standard of your particular country.
Electric shocks can occur if the POCm-W22/24C-ULT3 chassis is opened when the POCm-W22/24C-ULT3 is running. To avoid risk of electric shock, this equipment must only be connected to a supply mains with protective earth.
DO NOT LEAVE THIS EQUIPMENT IN AN UNCONTROLLED
ENVIRONMENT WHERE THE STORAGE TEMPERATURE IS
BELOW -20° C (-4°F) OR ABOVE 60° C (140° F). IT MAY DAMAGE
THE EQUIPMENT.
Do not drop or insert any objects into the ventilation openings of the
POCm-W22/24C-ULT3.
If considerable amounts of dust, water, or fluids enter the
POCm-W22/24C-ULT3, turn off the power supply immediately, unplug the power cord, and contact the POCm-W22/24C-ULT3 vendor.
14
DO NOT: o Drop the POCm-W22/24C-ULT3 against a hard surface. o Strike or exert excessive force onto the LCD panel. o Touch any of the LCD panels with a sharp object o In a site where the ambient temperature exceeds the rated temperature
Product Disposal
CAUTION:
Risk of explosion if battery is replaced by an incorrect type. Only certified engineers should replace the on-board battery.
Dispose of used batteries according to instructions and local regulations.
Outside the European Union - If you wish to dispose of used electrical and electronic products outside the European Union, please contact your local authority so as to comply with the correct disposal method.
Within the European Union–The device that produces less waste and is easier to recycle is classified as electronic device in terms of the
European Directive 2012/19/EU (WEEE), and must not be disposed of as domestic garbage.
EU-wide legislation, as implemented in each Member State, requires that waste electrical and electronic products carrying the mark (left) must be disposed of separately from normal household waste. This includes monitors and electrical accessories, such as signal cables or power cords. When you need to dispose of your display products, please follow the guidance of your local authority, or ask the shop where you purchased the product. The mark on electrical and electronic products only applies to the current European
Union Member States.
Please follow the national guidelines for electrical and electronic product disposal.
Classification
Power by Class I power supply (IEI, POCm-W22/24C-ULT3)
No Applied Part.
No protection against the ingress of water: IPX0
Mode of operation: Continuous Operation
15
The equipment not suitable for use in the presence of a flammable anesthetic mixture with air or with oxygen or nitrous oxide: Not AP or APG
Category.
EMC Test Summary
Guidance and manufacturer’s declaration – electromagnetic emissions
The model POCm-W22/24C-ULT3 is intended for use in the electromagnetic environment specified below. The customer or the user of the model
POCm-W22/24C-ULT3 should assure that it is used in such an environment.
Emissions test Compliance Electromagnetic environment – guidance
RF emissions
CISPR 11
RF emissions
CISPR 11
Harmonic emissions
IEC 61000-3-2
Voltage fluctuations/ flicker emissions
IEC 61000-3-3
The model POCm-W22/24C-ULT3 uses RF energy only for its internal function. Therefore, its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment.
The model POCm-W22/24C-ULT3 is suitable for use in all establishments, including domestic establishments and those directly connected to the public low-voltage power supply network that supplies buildings used for domestic purposes.
Recommended separation distances between portable and mobile RF communications equipment and the model POCm-W22/24C-ULT3
The model POCm-W22/24C-ULT3 is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the model POCm-W22/24C-ULT3 can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the model POCm-W22/24C-ULT3as recommended below, according to the maximum output power of the communications equipment.
Rated maximum output power of transmitter
W
Separation distance according to frequency of transmitter m
150 kHz to 80
MHz
80 MHz to 800
MHz
800 MHz to 2,5
GHz
0,01
0,1
1
10
100
d = 1,2
0,12
0,38
1,2
3,8
12
P d = 1,2
0,12
0,38
1,2
3,8
12
P d = 2,3
0,23
0,73
2,3
7,3
23
P
16
For transmitters rated at a maximum output power not listed above, the recommended separation distance d in metres (m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer.
NOTE 1: At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies.
NOTE 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people.
Guidance and manufacturer’s declaration – electromagnetic immunity
The model POCm-W22/24C-ULT3 is intended for use in the electromagnetic environment specified below. The customer or the user of the model
POCm-W22/24C-ULT3 should assure that it is used in such an environment.
Immunity test IEC 60601 test level
Compliance level
Electromagnetic environment – guidance
Electrostatic discharge (ESD)
IEC 61000-4-2
Electrical fast transient/burst
IEC 61000-4-4
Surge
IEC 61000-4-5
±6 kV contact
±8 kV air
±2 kV for power supply lines
±1 kV for input/output lines
±1 kV line(s) to line(s)
±2 kV line(s) to earth
±6 kV contact
±8 kV air
±2 kV for power supply lines
±1 kV for input/output lines
±1 kV line(s) to line(s)
±2 kV line(s) to earth
Floors should be wood, concrete or ceramic tile.
If floors are covered with synthetic material, the relative humidity should be at least 30 %.
Mains power quality should be that of a typical commercial or hospital environment.
Mains power quality should be that of a typical commercial or hospital environment. interruptions and voltage variations on power supply input lines
IEC 61000-4-11
<5 % UT
(>95 % dip in
UT) for 0,5 cycle
40 % UT
(60 % dip in UT) for 5 cycles
70 % UT
(30 % dip in UT)
<5 % UT
(>95 % dip in
UT) for 0,5 cycle
40 % UT
(60 % dip in UT) for 5 cycles
70 % UT
(30 % dip in UT)
Mains power quality should be that of a typical commercial or hospital environment. If the user of the model
POCm-W22/24C-ULT3 requires continued operation during power mains interruptions, it is recommended that the model
17
for 25 cycles
<5 % UT
(>95 % dip in
UT) for 5 sec
3 A/m for 25 cycles
<5 % UT
(>95 % dip in
UT) for 5 sec
3 A/m
POCm-W22/24C-ULT3 be powered from an uninterruptible power supply or a battery.
Power frequency
(50/60 Hz) magnetic field
IEC 61000-4-8
Power frequency magnetic fields should be at levels characteristic of a typical location in a typical commercial or hospital environment.
NOTE: UT is the a.c. mains voltage prior to application of the test level.
Guidance and manufacturer’s declaration – electromagnetic immunity
The model POCm-W22/24C-ULT3 is intended for use in the electromagnetic environment specified below. The customer or the user of the model
POCm-W22/24C-ULT3 should assure that it is used in such an environment.
Immunity test
IEC 60601 test level
Compliance level
Electromagnetic environment – guidance
Conducted
RF
IEC
61000-4-6
Radiated RF
IEC
61000-4-3
3 Vrms
150 kHz to 80
MHz
3 V/m
80 MHz to 2,5
GHz
Vrms
V/m
Portable and mobile RF communications equipment should be used no closer to any part of the model
POCm-W22/24C-ULT3, including cables, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter.
Recommended separation distance
d = 1,2
d = 1,2
P
P 80 MHz to 800 MHz
d = 2,3 P 800 MHz to 2,5 GHz where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer and d is the recommended separation distance in metres (m).
18
Field strengths from fixed RF transmitters, as determined by an electromagnetic site survey, a should be less than the compliance level in each frequency range. b
Interference may occur in the vicinity of equipment marked with the following symbol:
NOTE 1: At 80 MHz and 800 MHz, the higher frequency range applies.
NOTE 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. a Field strengths from fixed transmitters, such as base stations for radio
(cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy.
To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the model POCm-W22/24C-ULT3 is used exceeds the applicable RF compliance level above, the model POCm-W22/24C-ULT3 should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as reorienting or relocating the model
POCm-W22/24C-ULT3. b Over the frequency range 150 kHz to 80 MHz, field strengths should be less than
V/m.
Contact Information
IEI Integration Corp.
No. 29, Zongxing Rd., Xizhi Dist.,
New Taipei City 221, Taiwan
TEL: +886-2-8691-6798
Fax: +886-2-6616-0028 www.ieiworld.com
19
advertisement
Key Features
- 6th Generation Intel® Core™ processor for exceptional computing power
- 4GB DDR4 memory for seamless multitasking and data processing
- 21.5" LCD display with 1920 x 1080 resolution for sharp image quality
- P-CAP touchscreen for intuitive and responsive user experience
- Three hot-swappable battery bays for uninterrupted operation
- IP65-compliant front panel for protection against dust and water ingress
- Fanless cooling system for quiet operation and extended lifespan
Frequently Answers and Questions
Does the POCm-W22C-ULT3 support wireless connectivity?
How many USB ports does the device have?
What type of storage options are available?
Can the brightness of the display be adjusted?
Is the device compatible with different operating systems?
Related manuals
advertisement
Table of contents
- 1 POCm-W22C-ULT3 POCm-W24C-ULT3
- 1 Quick Installation Guide
- 1 Version 1.01
- 2 Revision
- 2 Intended Use
- 2 Manual Conventions
- 3 Overview
- 4 Front Panel
- 4 Bottom Panel
- 5 Side Panel
- 5 Rear Panel
- 6 System Specifications
- 8 Installation Precautions
- 9 Mounting the System
- 10 Powering On the System
- 10 Shutdown Procedure
- 10 Turn off the power and disconnect the power cord.
- 11 Troubleshooting
- 11 System Maintenance
- 11 Maintenance and Cleaning
- 12 Accessories
- 12 Optional Items
- 15 Safety Precautions
- 16 Product Disposal
- 17 EMC Test Summary