Steamcore Pro-Series is a high-quality steam bath generator that's designed for easy operation and minimal maintenance. It's equipped with an inline filter to help reduce foreign particles in the water line, and it has an automatic rinse and flush feature to reduce calcium and other mineral deposits. The steam generator should be installed in an upright position on a solid, flat level surface. It's important to make sure the steam line comes out of the top, and the must be positioned so that the steam line comes out of the top.
PDF
Download
Document
Advertisement
Advertisement
SAUNACORE INSTALLATION GUIDE & OWNERS MANUAL Steamcore Pro-Series This Manual contains installation and operation instructions, specifications, maintenance information, and warranty information SAUNACORE Technical Hotline 905-951-6662 www.saunacore.com ATTENTION: THIS MANUAL MUST REMAIN WITH THE OWNER OR OPERATOR OF THE STEAM GENERATOR INSTALLATION INSTRUCTIONS FOR STEAMCORE STEAM GENERATORS & CONTROLS Inspection and Shipping Claim STEAMCORE Certified to CAN/CSA Std No. 88 Conforms to UL Std. 499 Saunacore manufactures high quality steam bath generators, sauna heaters, modular sauna rooms, do-it-yourself sauna material kits, infrared saunas, and much more. From our smallest residential unit to our largest commercial unit, our products are manufactured to meet stringent quality standards to offer you all of the benefits of a relaxing, restoring, steam bath or sauna experience. Every single unit is tested for proper operation before leaving our manufacturing plant. When we at Saunacore sat down to create a new steam bath generator, we acted on satisfying our customers wishes for Quality, Safety, Reliability, and Durability. We also made it Strong, Practical, and Powerful, by using the most advanced parts available. All of Saunacore's Steam Bath Generators and Sauna Heaters meet the applicable requirements by CSA, UL, and CE standards. Thank you for Purchasing a Fine Saunacore Product. If you have any questions you may call our Customer Service Line at 905-951 6662. Inspection and Shipping Claim Check for shipping damage upon receipt of the product. Saunacore is not responsible for damage to the product sustained during shipping. If damage is evident before unpacking, file a claim with the carrier. Once the product has been removed from the carton and before it is permanently installed, check the parts completely for damage resulting from shipping or handling. All products are factory tested for proper operation and water tight connections prior to shipping. If problems are detected, immediately notify Saunacore at 905951-6662 for Service. OWNER’S RECORD Model #: ______________________________________________ Serial #: ________________________________________________ Purchase Date: ______________________________________________________ Purchased From: ______________________________________________________ Installed By: ______________________________________________________ NOTE: Damage or defects which could have been discovered and repaired prior to installation and which are claimed after final installation of the product are excluded from our warranty 2 www.saunacore.com Generator Installation Instructions STEAMCORE Requirements for Proper Installation Typical Commercial Model 1.) Use copper or brass fittings only. (NEVER USE GALVANIZED FITTINGS) 2.) The water inlet, steam outlet, and drain need brass unions for easy removal. 3.) The Generator must be upright, accessible, and on a level surface. 4.) Unit may be installed up to 50 feet away from shower area. 5.) DO NOT use ABS, PVC or any plastic material for the steam line. 6.) DO NOT plumb a trap in the steam or drain line. 7.) Pitch steam line back toward generator and avoid perfectly level plumbed lines. 8.) Before connecting water line to the generator, flush water line into a five gallon pail to remove any slit or other materials that may be in the line. An in-line water filter is recommended. 9.) Make sure water is turned on to the unit before testing or operating the unit. Typical Residential Model 10.) Unit and Supply lines MUST be protected from freezing! Parts Enclosed Control Steamhead Steam Generator Pressure Relief Valve, coupling, & fittings. Tools Needed •Pipe Wrench •Tubing Cutter •Flaring tool (if flared fittings are used) •Pipe thread cap •Adjustable wrench •Screwdrivers (Phillips and Regular) •Solder & Flux •Drill motor •Propane Torch •Silicone Gun •Other tools as required CAUTION: If the unit is run without water, serious damage may occur! This possible damage is not covered under the limited warranty. All generators are designed to build NO PRESSURE during operation. This is for your safety. NOTE: Failure to follow installation instructions specificaly will cause the warranty to be void. 3 Installation Instructions STEAMCORE BEFORE INSTALLING Read these instructions before installation or service. Although the Steamcore Steam Bath Generator has been fully qualified for shipment by Saunacore, the following must be reviewed for proper, safe and enjoyable steam bathing. Verify that the model and accessories are correct, including line voltage. Insure steambath generator has been correctly sized for the steam room. Pay particular attention to room volume and construction. Marble or glass walls and ceilings, or exterior walls "ENLARGE" the room's size, requiring a generator larger than one based only on the room's cubic foot (L x H x W) volume. The physical size of the unit, clearance for plumbing, servicing, and its distance from the steam room must all be considered before final installation. IMPORTANT Steamcore units are intended to be operated with a Steamcore timer and/or temperature control only, and are to be installed strictly in accordance with the specific instructions supplied with these optional accessories and the information contained in this manual. CAUTION! Steamcore steam generators are connected to extremely high line voltage and contain live electrical components. All installation and service to be performed by qualified electricians and plumbers only. Installation or service by unqualified persons may void the warranty. Pressure Safety Valve(s) - (Supplied Only - must be installed on-site by plumber). 1. Safety valve is a safety equipment in order to prevent too much steam pressure in the steam generator due to various reasons; such as, steam line blockage, undersized steam lines, steam line traps, plugged steam outlets (vandalism), etc. 2. The pressure limit range of the safety valve(s) supplied is 15 psi. A Pressure Safety Valve (Steam Pressure Valve) has been supplied with this steam generator unit. The steam generator has a mounting location (labelled) for the pressure safety valve. A qualified licensed plumber must install the supplied pressure safety valve during installation of the steam generator. Attach by screwing the pressure valve onto the steam generator in the designated location using hi-heat silicone and allow to cure 24 hours before using steam generator. The pressure safety valve must be installed by a qualified licensed experienced plumber. Steam generators 18 KW (18000 watts) and higher will have a factory installed 10 psi Steam Pressure Switch. This switch will cut power to the steam generator when the inside boiler tank or steam line(s) pressure exceeds 10 psi. The switch will reset and activate power when the pressure drops below the 10 psi factory set range. 4 www.saunacore.com Steam Room Requirements STEAMCORE STEAM ROOM: If you are using an existing shower or bathtub, make sure that it is completely sealed right up to the ceiling. The ceiling and walls must be tiled or covered with water resistant material. If you are building a steam room, talk to someone that has experience with the construction of steam rooms. Steam rooms must be constructed differently from any other type of room. STEAM ROOM REQUIREMENTS: 1.) Steam room must be completely enclosed, with full walls, door, floor and ceiling. 2.) It is recommended that a gasketed door is used for heat sealing and steam containment. 3.) If tile flooring is used, install anti-skid strips or equivalent, for safety. 4.) Walls and ceilings must be covered with water-resistant, non-corrosive surface, such as tile, molded acrylic, fiberglass, etc. 5.) Provide a floor drain. 6.) Ceiling and seat must slope slightly to allow condensate to runoff. (Ceiling slope 2” per 1 ft) 7.) Steam generator must be on a flat surface, in an area where it would be accessible, dry, and where it will not freeze. The steam lines should always slope either towards the generator or towards the steam heads as not-to allow the formation of condensate to accumulate. 8.) All inside surfaces should be adequately sealed. Around faucets, shower head, and steam heads should be sealed with mildew resistant silicone. 9.) Ceiling height should be no higher than 7ft to 8 ft, preferably 7 ft. 10.) Room should be insulated with not more than a maximum R-12 value. A higher R-value may cause room to heat to quickly and not allow steam to condense normally. 11) Steam lines over 10 ft should be insulated. Ventilation: NOTE: These are only suggestions. Saunacore manufactures quality steambath generators and sauna heaters; therefore we cannot warrant information regarding materials and construction methods of steam room and sauna room. Generally, steam rooms which are used at a maximum of two hours at one time do not require any special ventilation. Steam rooms which are continously used more than two hours at a time should be ventilated with a ratio of 10-20 cubic meters of air per person per hour. The air inlet maybe placed down low on the same wall as the door or a gap under the door. the air outlet should be up high as far away from the inlet as possible. Do not locate above door or over seats. Outlet should be connected to a vent duct leading to open air. Duct should be 100% steam and water tight. Avoid sags in duct which may cause water pockets, that will block outlet, due to condensation. 5 Locating the Steamcore Steam Generator Unit STEAMCORE Locating the Steamcore Steam Generator Unit: 1. Plan the location for mounting your steam generator. 2. Do not install generator inside steam room. 3. Do not install generator outdoors. 4. Do not install generator near combustible or corrosive materials or chemicals. 5. Place the generator in a dry and easy accessible location for future periodic maintenance. Locate steambath generator preferably within 25 feet of the steam room, though it may be placed up to 50 feet away. 6. A gravity drain will be necessary for all units. 7. Never locate a unit that may be exposed to frost, fire, or high moisture.Do not install steambath generator in unheated attic or basement where water could freeze. 8. The unit must be located on a solid and flat level surface. 9. Install generator in an upright position only. 10. Steam line, and drain valve become hot during operation. Provide appropriate protection. Example: A ceramic steam shower with the demensions 7ft length by 5ft wide and 7ft high (7ft x 5ft x 7ft = 245), is 245 Cubic feet. 11. Commander Controls and Air Switch Control can be located inside the steam room or on the outside of the steam room. See seperate control installation and operation instructions for specific details. Mechanical controls are located outside the steamroom, a remote sensor is required for all controls 12. Install anti-water hammer device as required. 13. Provide access to both ends of the steambath generator for servicing. Since the steam shower has ceramic wall finishes, it then requires a 25% cubic footage increase. Steam Bath Generator (Sizing and Selection) (Ceramic tile) 25% x (steam shower) 245 = 61.25 ft Measure the length, width and height (in feet) of the steam shower. Multiply the three measurements together to get the basic volume in cubic feet. The wall finish cubic feet is then added to the origin dimensions to calculate the total cubic, which in this case is 306.25 ft. (ceramic tile) 61.25 + (steam shower) 245 = 306.25 ft Now select the next size of Steamcore model generator which exceeds the calculated room cubic feet. This case the KWS (9000 watts) generator is required. If there is doubt in size, it is recommended to choose the next larger size. 6 L x W x H = CUBIC FEET x % (wall finish) Add the cubic footage to one of the wall finishes Ceramic Tile 25% Natural Stone 100% Fiber Glass/Acrylic 0% Steam Line 50ft+ 20% Glass Block Wall 10% Steam Line Subject to Freezing 25% Glass Wall 10% www.saunacore.com General Installation Instructions (All Steam Bath Units) STEAMCORE Steam Generator Positioning: The steam generator must be properly positioned for it to work. Place the steam generator TOP UP, which will be indicated on the Unit with arrows. The steam line(s) are on the top of the unit. The water inlet, electrical connection box, and drain are on the sides of the unit. Installation in any other way will cause malfunction or damage to you steam generator, voiding your warranty. Water Connections: CAUTION !! The steam head(s) (or nozzle(s)) create very high degree of temperature in and around the steam heads during use. The steam heads should be installed as far away from any bathers path. Bathers are to avoid this area and from any direct contact to the steam heads. Burn or injury may occur if touched or in the vicinity during use. Appropriate protection should be provided to avoid injury. All plumbing shall be performed by a qualified plumber and in accordance with applicable National and Local codes. Use unions on all pipe connections. Use only brass piping or copper tubing. Do not use black, galvanized or PVC pipe. Connect your water supply (cold water) to your unit with a ¼, ½ or ¾ inch soft copper tubing. An inline filter has been installed by the factory. When connecting the steam lines, drain, and the pressure relief loop (commercial units) one must use two wrenches, one to hold the fitting from the steamer and the other to tighten the fitting which is being connected. 1. Connect hot or cold water line. Hot water should not exceed 160 degree Fahrenheit. (Cold is preffered) 2. Provide a shut off valve in the supply line. 3. Do not overheat inlet solenoid valve with solder connections. Overheating will damage parts. 4. Flush inlet water line thoroughly before making connection to unit. 5. Strainer is required if there are solid particles in the water. 6. For proper performance water pressure must be 15-20 psi. Electrical Connections: All electrical wiring to be installed by a qualified and licensed electrician in accordance with National and Local codes. All power rating, electrical connections and wiring is clearly labeled on all units. 1. Check power voltage. (Most homes have 240V, IPH service). 2. Use minimum 90 deg. C/300V copper conductors only, sized in accordance with National and Local electrical codes. 3. Connect equipment grounding wire to ground terminal provided. 4. Install a separate circuit breaker between supply and unit. 5. On single phase units, use two-wire supply source with ground. Neutral (white) wire is not required, but may be used . 6. A suitable metal conduit and metal conduit connector should be used for the main power wiring connections. The total connected load should not be more then 80% of the rating of the overcurrent devices. 7 General Installation Instructions (All Steam Bath Units) STEAMCORE Steam Connections: A ½ inch union fitting is supplied at the single steam outlet on KWS 2, KWS 3, KWS 4.5, KWS 7.5 model generators that will use one steam head. A 1 inch union fitting is supplied at the steam outlet on all KWS 9 to KWS 36 model generators. All 1 inch steam outlets on the unit must be reduced to CAUTION !! two ½ inch lines using a T reducer before reaching the steam room and the The steam head(s) (or nozzle(s)) create very ½ inch pipe length to be close to equal lengths to the steam room. Each 1 high degree of temperature in and around the inch steam line on your unit will require two standard steam heads or one steam heads during use. The steam heads should be installed as far away from any bathers designer steam head. (Depending on the model, your steam generator may path. Bathers are to avoid this area and from any have up to 4 - - 1 inch steam outlets on the unit that will be reduced to 8 ½ direct contact to the steam heads. Burn or injury inch steam lines to the steam room, using 8 standard steam heads or 4 may occur if touched or in the vicinity during use. designer steam heads). Do not have any low points in the line that will allow Appropriate protection should be provided to condensation to sit in the steam line(s). The steam heads should be avoid injury. mounted approximatly 10 to 12 inches above the floor and 6” away from a corner, located in an area where you will easily avoid physical contact. Direct the steam head(s) outlet slot down and the fragrance reservoir up. If steam room is provided or built with seat(s), locate steam head as far away from seat as possible. Drain: This is a gravity draining system on all model steam bath generators. A ½ inch compression fitting is supplied with the unit and is to be installed on a ½ inch copper pipe that slopes slightly downwards and away from the unit. It can be plumbed into an existing drain line or to an open floor drain. If there is absolutely no drain available, you may direct it into the shower/ steam room. When connecting, you must use the two wrench method or you may break the seal on the connection between the drain pipe and the boiler tank, and cause leakage. Testing: Now that your Steamcore is connected, you must test it. 1. Turn on your water supply and check for leaks. 2. Turn on your power supply at the electrical panel; be sure the unit is receiving power. 3. Set the 30 minute mechanical timer to the desired time and wait for steam. NOTE: To preserve steam head finish, do not use wrench or other tools to tighten. Hand tightening is sufficient when Teflon or equal pipe thread sealing compound is used. Option: Elegance Controls - - set temperature and press on Option: Press Air Switch until red LED Light comes on and wait (pre-programmed 30 minute timer and temperature set at 50 degrees Celsius) 4. Within a few minutes your steam room should begin to fill with steam. NOTE: 5. Check to make sure your steam lines do not leak condensation and steam. A drain valve is provided to facilitate servicing. Where local codes permit, provide a drain line connection from a generator drain valve. Check local plumbing code for receptor, trap and vent requirement. Unit drains by gravity. Slope down. 6. You may want to insulate the steam lines with pipe insulation; this is strongly recommended if your steam generator is more than 10 feet from the steam room. 8 www.saunacore.com General Installation Instructions (All Steam Bath Units) STEAMCORE Rinse and Flush Operation: (Silver and Gold Models Only) All units have the pre-programmed rinse and flush feature. This will automatically take place after each steam bath, it will happen approximately 10 minutes immediately after the steam generator has finished being used and the set time has expired. On the units with the manual drain (Bronze Package), the Rinse and Flush operation will not occur. Manually open the drain valve immediately after the steamer stops, and then close the valve when ready for the next steam bath. Filtration: Your steam bath generator has been equipped with an inline filter from the factory. You may want to add your own secondary external filter or water softener, although it is not mandatory. This helps reduce foreign particles that may pass through the water line and lodge in the solenoid valve. Calcium and other mineral deposits is the number one reason for steamer breakdown. A secondary filtration system will add additional help to reduce or remove these components from the water prior to it entering the unit which will help extend the life and minimize maintenance schedules of the steam bath generator. Maintenance: Saunacore steambath generators are designed for unattended operation and require little maintenance. Other than periodic draining, maintenance procedures are not required. Every 2 months, or more often in "hard" water areas, the drain valve should be opened fully flushing out accumulated materials, salts, and other particles that are natural by-products of boiling water. Note: For best results, this should be done immediately after using the steambath generator, while contents are still hot and with the control off. Semi-annual maintenance is strongy recommended for commercial units. Contact Saunacore for details. IMPORTANT: Residential build-up from poor water quality may cause an incorrect reading of the water level control circuit. If this happens, your steam generator will attempt to clean and flush the system, if that does not work, it will shut down completely and the led display on the keypad will flash continuously. This is an indication that your water level control circuit needs service. The main cicuit breaker should be switched off immediately and kept off untill the problem has been corrected. 9 General Installation Instructions (All Steam Bath Units) STEAMCORE Automatic Rinse and Flush Operation (Silver and Gold Models Only) This automatic function considerably reduces the buildup of calcium carbonate and other deposits in the water reservoir. Do not switch off any switches between the main supply and the steam generator until at least 60 minutes after the control panel timer has turned the system off, otherwise, the automatic emptying and flushing of the water reservior will not start. WARNING: The water is very hot. Drainage from Steam Generator The pipe must lead directly to the nearest drain outside the steam room itself. The temperature of the water that is drained off is approximately 95°C/200°F. IMPORTANT! There must be no blockage of any type (tap, faucet, etc.) along the drainage pipe. Regardless of where the drainage head is located, it must slope all the way from the steam generator to the waste outlet. Under certain conditions, it may be necessary to place the steam generator on the wall brackets or a stand to achieve the right angle. Cleaning the Steam Room Rinse seats and flooring with warm water (do not use a high-pressure hose) each time the steam room has been used. Wash the seats regularly with a mild soapy solution. Stubborn stains can be removed with ethanol or petrolem (mineral) spirits. Never use scouring powder, strong alkaline cleaners or aggressive solvents on the seats and walls in the steam room. It is important that the steam room floor is cleaned thoroughly - right into the corners. Scrub Clean with hot water and floor cleaner, which will remove grease and grime. Shower in the steam room We always recommend installing a shower in domestic steam rooms. After all, a steam room also makes the best shower room imaginable. And it is so pleasent to cool off with an ivigorating shower now and again during a steam bath. 10 www.saunacore.com General Installation Instructions (All Steam Bath Units) STEAMCORE How to make the most of a steam bath. Most people find that the most comfortable steam bathing temperature is between 40 and 45°C. Use a bimetallic type of thermometer to check the temperature. Fix it on the wall about 180 cm (72”) above floor level, as far from the steam jet as possible. There is no need for a hygrometer. The relativity is always 100%. • Shower and wash before starting your steam bath • Take a towel to sit on in the steam room • Relax and enjoy the soothing clouds of steam. • Cool down now and again with a refreshing shower. Alternate between the steam bath and the shower for as long as you feel comfortable. • After your last spell amongst the clouds of steam, you’ll find a long, cool shower a real delight. Let your body dry off naturally before putting your clothes on. Relax, treat yourself to a cold drink and enjoy a sensation of true well-being. Don’t get dressed until your body has cooled down and your pores have closed once again. CAUTION !! The steam head(s) (or nozzle(s)) create very high degree of temperature in and around the steam heads during use. The steam heads should be installed as far away from any bathers path. Bathers are to avoid this area and from any direct contact to the steam heads. Burn or injury may occur if touched or in the vicinity during use. Appropriate protection should be provided to avoid injury. 11 Typical Residential Plumbing Installation (Elegance Model) STEAMCORE KWS2 - KWS12 Typical Residential Plumping Installation with Elegance Steam Head 1" Steam LIne Add Pressure Valve into Steam Line (use 3 way connection "T") Steam Room 1" Water supply 1" or 1/2" Steam Line Outlet Main Power Supply Drain One Elegance Steam Heads 1" 10"-12" Air Gap 1/2" Pipe Slope Down Floor Floor Drain Steam Head Installation STEAMCORE ELEGANCE STEAM HEAD INSTALLATION 3/4" NPT Female (made with solid brass) CORE SAUNA Elegance Steam Head 12 Typical Commercial Plumbing Installation (Elegance Models) STEAMCORE KWS 9 - KWS 18 Commercial Plumbing Installation with Elegance Steam Head(s) Water supply Main Power Supply 3/4" Pressure Steam Room Two Elegance Steam Heads " 3/4 or " 1 1" 1" or 3/4" Steam Line 10"-12" 1/2" pipe slope down Floor Floor Drain Air Gap Floor Drain KWS 22.5 - KWS 36 Commercial Plumbing Installation with Elegance Steam Head(s) Water supply Main Power Supply 3/4" Pressure Steam Room 1" Steam Lines Six Elegance Steam Heads 1/2" pipe Floor Drain slope down Air Gap Floor Floor Drain 10"-12" Note: All 1" steamlines must split and have 2 steam heads. Total of 2 steam heads per 1" steam outlet. 13 www.saunacore.com Steam Head Installation STEAMCORE A 15 p.s.i. Pressure Relief Safety Valve and coupling has been supplied with your steam generator unit. It must be installed on-site by a qualified licensed plumber. Use adequate silicone or tape sealant to prevent any steam leakage from the connection. This must be done on Residential & Commercial units. A 15 PSI Pressure Relief Valve and coupling has been suppli It must be installed on-site by a qualified licensed plumber Use adequate silicone or tape sealant when threading onto st prevent steam leaks for connections. 4 www.saunacore.com General Installation STEAMCORE 1.) Under NO circumstances is the steam line from the steam generator to be restricted or reduced to less then 1/2” inside diameter, or contain a steam trap. Steam line distance maximum 50 ft. 2.) Under NO circumstance should there be a valve or other obstruction in the steam line. 3.) Water MUST be able to drain from all sections of the steam line at all times. 4.) Adequately treat impure water or warranty policy may become null and void. 5.) The steam generator MUST be positioned so that THE STEAM LINE COMES OUT OF THE TOP. 6.) Use only factory supplied modular connector with any unit, any substitute connector will void warrenty. 7.) Cutting or tampering with internal wiring will void warranty. 8.) Timer switch may not automatically turn on appliance if knob is not first rotated past “turn past” point ( “dot” above 5 minute mark) on the mechanical timer switch. Enjoy Aroma essential oils by placing a drop or two into your steamhead as shown in the attached illustration. Only use Steamcore Aroma Essential Oils in a Steamcore steam head, or any other equivalent oil deemed suitable for use in the Steamcore steamhead. Caution: AROMA 10 ML BOTTLE WITH INTEGRATED DROPPER • Use essential oils with caution. Essential oils are for external use only. Keep out of reach of children. Essential oils are higly concentrated and are potent substances and should not be applied directly to the skin as they can be irritants. Use essential oils with caution. RECESS FOR ESSENTIAL OIL • Place the drops into the steam head recess prior to turning on the steambath. Do not place drops in a hot steam head as SERIOUS INJURY CAN RESULT IF YOU DO NOT FOLLOW THIS WARNING. ELEGANCE STEAMHEAD STEAM EMISSION SLOT • Start with one drop to gauge strength and suitability. Limit to a maximum of a few drops during a steambathing session. Some people may find that the aroma makes them dizzy and the user should exit the steam bath aIMMEDIATELY. If skin iffitation occurs stop using the oils immediatly. Remove any excess oil by washing in mild soap and water. If ingested, rinse mouth with water. Administer water or milk to dilute. Contact a physician immediately. Tightly close containers when storing oils. Keep away from sources of ignition. 15 Control Installation STEAMCORE SS I Control L3 G Temperature Sensor (Locate in Steam Shower) G NOTE: SS I Control ma y be located inside or outside of the steam room. The SSII control must be installed in the steam shower. SSII control has the steam shower temperature sensor built into the control keypad. Main power supply in conduit or use bx (L1, L2, L3, and Ground.) SSI CONTROL 1. Locating the Control Inside or Outside the Steambath enclosure: The SSI Control is designed to be installed inside or outside the steambath enclosure according to personal preference. It is recommended that the SSI Control is located about 4 to 5 feet above the floor. The control should be located away from direct shower spray and must be kept away from hot piping and steam piping. SSI or SSII control may be siliconed to wall finish. 2. Determine if the installation of an electrical box is required. CAUTION: Do Not route the SSI or SSII Control cable inside conduit together with power lines or close to hot water or steam piping. Doing so may result in a malfunctioning control. The SSI and the SSII Control operates on low voltage signal. Check your local building codes to determine if the use of an electrical box is required. 3. The SSI or SSII Control cannot be used together with any other controls. 16 User Manual Control panel (both SSI and SSII) dimension SSI and SSII Control panel may be switched for Spa II 160mm 120mm 70mm 23mm SS I 113mm 75mm SS II 17 25mm User Manual Installation instruction of controller ! Important: Step one Before installing the controller, make sure the steam generator is shut off otherwise the controller may be damaged. Determine the installation location of the controller. The controller is designed to be installed in the steam room : 1. 4-5 feet from the ground. 2. Away from the steam nozzle and do not expose under the direct path of steam. 3. Installation on perpendicular wall. 4. The position of installation should facilitate easy operation and convenient wiring. The controller wire is 1.0 feet long with a controller lengthened wire of 20 feet long at the most. In the installation of controller, it should be in a position not more than 21 feet from the steam engine. If longer wire is needed, contact professional service personnel. ! Important: Do not install the controller under the water pipe or in a position where water comes into contact. Control Panel SS I Step two Drill a round hole of 35mm in diameter in a chosen position, no larger or smaller. (1ft) Step three Pull the controller wire through the round hole, connect it to the lengthened wire and then to the steam generator , and connect with the corresponding wire in generator . When the computer wire is plugged in, aim the the direction and insert horizontally, instead of shaking at left and right in case the computer needles could be damaged. Do the same when unplugging. Control Panel Extended wire (20ft) Important: Do not pull tight, or clip tight the controller wire in case of causing damage to it. Step four Start the power supply of steam engine, check and adjust connection, check each item on the page to make sure all functions work well. 18 Aor (1ft) ! ! Important: before repairing the controller, make sure the steam generator is shut off otherwise the controller may be damaged. SS II Steam Generator User Manual Step five Remove the paper on the b ackside . To achieve good sticking effect, keep the mounting surface clean and dry. Step six Locate the display screen in the direction of 12 o'clock, and press tight the controller to stick it to the wall. Control Panel SS I Control Panel SS II Control Panel SS I Control Panel SS II ! Important: To ensure horizontal installation of the controller, use a level if necessary. Temperature sensor installation(only for SS I Control Panel ) 1.The position of the temperature sensor should be within a range of 1.2-1.5M above the ground. Try to avoid installing near the steam nozzle or the opening side of the steam room door. 2.As shown in Fig.1, drill a small hole of 10mm in the selected position. 3.Apply a circle of silicone along the edge of the back of the sensor base (as shown in Fig.2). 4.Use a locknut to lock the sensor foundation. (As shown in Fig.2) 5.Let the temperature sensor go through the back of the sensor holder (As shown in Fig.3) 6.The temperature sensor should be installed by extending about 1cm from the front of the room to make sure the speed and accuracy of temperature control. 7.Apply silicone to the back and fix the sensor. (As shown in Fig.3) 1cm Temperature sensor 10 Temperature sensor base (optional) Locknut for temperature sensor base Drill Ground (Fig.1) (Fig.2) (Fig.3) 19 1.2~1.5m User Manual Illustration of the controller panel (SS I Control Panel) IN/OUT SHOWER USE 6 6 24 3 27 8 2 5 29 10 1 1 Power ON/OFF 6 LED SCREEN 2 Power Indicator LED 7 Steam Time Adjust Key--LOW 3 Steam Temperature Adjust Key--LOW 8 Steam Time Adjust Key--HIGH 4 Steam Temperature Adjust Key--HIGH 9 Mood Light Indicator LED 5 Steam ON/OFF 10 Mood Light ON/OFF Operation instruction (SS I Control Panel) The controller is digital temperature control system which can start, stop or pause in the preset time to keep the temperature in the set number. Power ON/OFF When unit is powered on, power indicator LED should be lit. Press and release button to activate system and all function buttons. Meanwhile, power indicator LED goes out. Water input steam boil tank automatically, and LED screens display system, press . Shut down the button again. System drains out water in generator water tank automatically. (NOTE: If power indicator LED flashes when system is activated, it reports that generator water tank is lack of water. System shuts down power supply to heater elements, and opens water inlet valve to refill water until reaching required volume.) 20 User Manual Mood Light When system is activated, press and release button to turn on the mood light. Indicator LED on the right of the button should be lit. Press and release button again to shut down mood light. Steam ON/OFF When unit is powered on, press and release button, water input steam boil tank automatically, press and release button, steam starts emitting. Press button again to stop steam. Steam Time Setting Use and buttons to set desired steam time when system is activated. Steam time LED screen shows set time from 1~99 minutes. System shuts down power supply to heater elements automatically when desired steam time is over. Steam Temperature Setting Use and buttons to set desired steam temperature when system is activated. Steam temperature LED screen shows set steam temperature ranging from 25 ~68 or 78 F ~150F.When ambient temperature is higher than desired temperature, system shuts down powersupply to heater elements automatically. Meanwhile, temperature readings on LED screen flash until ambient temperature gets lower than set temperature. Select Temperature Unit TEMP When system has been turned off, press TIME and buttons at the same time, LED screen shows current temperature unit. 21 User Manual Illustration of the controller panel (SS II Control Panel) IN SHOWER USE ONLY 9 7 8 4 1 5 2 6 3 10 Power switch Time set button Time/temperature increase button Temperature set button The front decorative panel Time/temperature decrease button Light function button Digital display screen Steamcore Temperature sensor Operation instruction (SS II Control Panel) The controller is digital temperature control system which can start, stop or pause in the preset time to keep the temperature in the set number. ON/OFF When it is electrified, the system shuts off all the loads to remain in a waiting state, and the digital tube will display ---(as is shown in Fig.1). In the waiting state,press button to turn on the system and the steam function. The default time of starting the steam is 30 minutes and it begins to count down and the default temperature of the steam is 100F. After the system is started, the digital tube will display the current temperature of the environment and the temperature check range is 32F-140F. 22 Fig.1 User Manual When the actual temperature is smaller than or equal to 32 , the digital tube will display 32 . When the actual temperature is smaller than or equal to 140 , the digital tube will display 140 . The last digit displays as the unit of Fahrenheit temperature. The default start time of steam function is 30 minutes. When the steam is starting, there is a shortage of water, the heating wire will stop heating and the water input valve will start automatically. If there is no water tested in 5 seconds or no water coming to reach the full volume in 15 seconds, the digital tube will flash to display (as shown in Fig.3) to hint mistake. If the water is full, the steam function will return to normal. When the steam function is started, if the temperature of the environment is higher than the set steam temperature, the heating wire will stop heating, the digital tube will flash to display the current environment temperature; when the environment temperature is lower than the set steam temperature, the heating wire will restore heating, the digital tube will display normally current environment temperature. When the system is started, press button or when the steam function time is due, the system will be shut. 10 minutes after the system is shut off, the drainage function will be started automatically for 5 minutes. Fig 2 Fig.3 Time setting When the machine is started, press button and the digital tube will display the remaining time of current steam function (as shown in Fig.4), press button or button to adjust the remaining time. The adjustment range is 1-99 minutes with 1 minute as one level. If there is no adjustment in 5 seconds, the system will quit the time setting function. The digital tube will restore to display current environment temperature. Fig.4 Temperature setting Whenthemachine is started,press button and the digital tube will display the set steam time (as shown in Fig.5), at the same time the temperature unit will flash to hint that the machine has entered the steam temperature setting function. At this time, press button or button to adjust the temperature parameter. The adjustment range is 50-130 with 1 as one level. If there is no adjustment in 5 seconds, the system will quit the temperature setting function. The digital tube will restore to display current environment temperature. 23 Fig.5 User Manual Light function When the machine is started, press button repeatedly to turn on/off light function. When the light is turned on, the digital tube will temporarily display (as is shown in Fig.6). When the light is turned off, the digital tube will temporarily display (as is shown in Fig.7). Fig.6 ! CAUTION: 1.Please consult your physician before using.If you are pregnant,elderly,have high blood pressure,diabetes, suffering from heart disease, intoxicated,or not in good health, do not use this steam bath. 2.Children must be accompanied with adults when using this steam bath. 3.Steam is hot! Severe burn will occur if you come in contact with the steam head or steam emitting from the steam head. Fig.7 Maintenance of the steam generator ! Important: perform water discharge operation after each use. 1. Wait for the completion of automatic water discharge after each time of using the steam generator to make sure the water in the tank is discharged completely before cutting off power supply. 2. There should not be any leakage or damage among the steam generator , steam nozzle, components and pipes. They should be checked and repaired annually. 3. Clean the water supply pipes of the steam generator once a year. 4. Check all the connections, faucets and connection terminal to see whether they become loose or are damaged due to overheat. 5. Check the furring accumulated in the water tank and electric heating tube. If the furring is thick, dispose it in time (use diluted lemon acid to soak for 15-30 minutes). 6. Remove the water level sensor needle once every 3-4 months to clean scaling. 24 -OOD,IGHT#ONTROL ! # " ! 0OWERONOFF " # -ANUALCOLOURCHANGE !UTOMATICCOLOURCHANGE &UNCTION )NSTRUCTION !0USHBUTTONTOACTIVATEUNITSYSTEMRECALLSALLFUNCTIONS UNFINISHEDTHELASTTIMEUSEDANDPRESETsWORKINGTIMETO MINUTESBY DEFAULT0RESS"UTTONTOCHANGELIGHTCOLOURAUTOMATICALLY0USH ,IGHTCOLOURMANUALLY0USHAGAINTODEACTIVATE BUTTONTOCHANGE SYSTEM "#HANGECOLOURAUTOMATICALLY 7HENUNITISPOWEREDON0RESSBUTTONLightCHANGEsCOLOURAUTOMATICALLY ASPREPROGRAMMEDANDEACHCOLOURREMAINSFORSECONDS0USHBUTTON AGAINLAMPKEEPSPRESENTCOLOURPUSHBUTTONFORTHETHIRDTIMELAMP GOESBACKTOCHANGINGCOLOURAUTOMATICALLY ##HANGECOLOURMANUALLY %ACHTIMEBUTTONISPRESSEDLIGHTCHANGESONECOLOURINTHEFOLLOWINGORDER 7HITEREDPURPLEBLUEYELLOWGREENORANGE Page 25 -OOD,IGHT#ONTROL 4ECHNICAL$ATE 6OLTAGEINLET 6OLTAGEOUTLET /THERS 7ORKING#ONDITION !#6 2ATED&REQUENCY $#6 2ATEDCURRENT -AXINPUTVOLTAGE$#OFLAMP 6 MAX (: M! $#6 2EMARK )NPUTVOLTAGEISASSOCIATEDWITHTHESUPPLIEDTRANSFORMER)TCANBE6INLETVOLTS 5NITWOULDBEDAMAGEDIFTHEINPUTVOLTAGEEXCEEDTHE-AXLIMIT Page 26 0AGE Wiring Diagram 208V (3PH) Steamcore Ce1g Supply Water Level Sensor L3 L2 L1 To Control Panal Red(Short Pin) Black(Long Pin) Yellow(Middle Pin) G J1 Terminal Block Yellow/Green J3-2 J2-1 J3-1 J1-2 J1-1 J2-2 J2 J3 Blue Red Optional Light manual reset hi-limit Black Red Brown auto reset hi-limit Red Red S Red Black Red Drain water valve Yellow S Red Red Fill water valve Black Red Black Red 12 psi pressure switch (UL - USA Application 18kw & Up) Steamcore 15kW / 18kW (208V - 3PH) Supply L3 L2 L1 G Water Level Sensor To Control Panal Red(Short Pin) Black(Long Pin) Yellow(Middle Pin) Terminal Block Light Red J1-1 Red Red J1-2 Red J2 Black Black Optional Brown Red Red Steamcore auto reset hi-limit Red Red Blue Red Red Drain water valve Yellow S Red Red Fill water valve S Red J2-1 Red J1 Yellow/Green Black Red manual reset hi-limit Black Red 9kW (208V - 3PH) Supply L3 L2 L1 G Water Level Sensor To Control Panal Light Brown Red J3-1 Red Red J2-1 Red Red J1-2 Red Red J1-1 Red Red J2-2 Red Red J3-2 Red J2 J3 Black Black auto reset hi-limit Optional Red Red Red Red Blue Yellow/Green Red Red Drain water valve Yellow S Red Red Fill water valve Black Red S Terminal Block J1 Red(Short Pin) Black(Long Pin) Yellow(Middle Pin) manual reset hi-limit Black Red Steamcore 10.5kW / 12kW / 13.5kW (208V - 3PH) Page 29 European Connection ( L2 = N "Neutral") Technical Specifications STEAMCORE Aroma Therapy Pure Oils Available • • • • • Eucalyptus Lavendar Relaxation Blend Sensuality Blend Stress Relief Blend Residential Model # Watts Recommended Max. C.U.Ft. KWS 2 2000 30 KWS 3 KWS 4.5 KWS 6 KWS 7.5 KWS 9 KWS 10.5 KWS 12 3000 4500 6000 7500 9000 10500 12000 50 65 175 250 375 450 525 Commercial Model # Watts Recommended Max. C.U.Ft. KWS 9 9000 375 KWS 10.5 10500 450 KWS 12 12000 525 KWS 13.5 13500 625 KWS 15 15000 685 KWS 18 18000 750 KWS 22.5 22500 925 KWS 27 27000 1125 KWS 31.5 31500 1275 KWS 36 36000 1400 • Call for accessories. Commercial units available up to 600 volts. For warranty details see warranty card. All steamers meet Canadian, USA & European safety standards. Saunacore reserves the right to change, alter or discontinue models. Items and colors may not be exactly as shown. Sizes are approximate. Not liable for any misprint. Consult with physician before use. Steam generators over 40 amps may require more than one dedicated main power supply. Call for details. Note: Saunacore reserves the right to change, alter or discontinue models. Sizes are approximate. Not liable for any misprint. Volts / ph / AMPS Steam Line Size of Line 1/2” Standard Steam Head 3/4” Elegance Steam Head 1 1/2” 1 1 1 1 1 1 1 1 1 1/2” 1/2” 1/2” 1/2” 1” 1” 1” 1 1 1 1 2 2 2 1 1 1 1 1 1 1 Volts / ph / AMPS Steam Line Size of Line 1/2” Standard Steam Head 3/4” Elegance Steam Head 240V / 1 / 37.5 208V / 1 / 43.3 208V / 3 / 24.0 450V / 3 / 11.6 575V / 3 / 9.1 240V / 1 / 43.8 208V / 1 / 50.5 208V / 3 / 29.2 450V / 3 / 13.5 575V / 3 / 10.6 2 1” 4 2 2 1” 4 2 240V / 1 / 50.0 208V / 1 / 57.7 208V / 3 / 33.4 450V / 3 / 15.4 575V / 3 / 10.6 240V / 1 / 56.3 208V / 1 / 64.9 208V / 3 / 37.5 450V / 3 / 17.3 575V / 3 / 13.6 2 1” 4 2 2 1” 4 2 208V / 3 / 41.7 450V / 3 / 17.3 575V / 3 / 13.6 208V / 3 / 50.0 450V / 3 / 19.3 575V / 3 / 15.1 2 1” 4 2 2 1” 4 2 208V /3 / 62.5 450V / 3 / 28.9 575V / 3 / 22.6 208V / 3 / 75.0 450V / 3 / 34.7 575V / 3 / 27.1 3 1” 6 3 3 1” 6 3 208V / 3 / 87.5 450V / 3 / 40.5 575V / 3 / 31.7 208V / 3 / 100.0 450V / 3 / 46.2 575V / 3 / 36.2 4 1” 8 4 4 1” 8 4 120V / 1 / 16.8 240V / 1 / 8.4 240V / 1 / 12.5 240V / 1 / 18.75 240V / 1 / 25.0 240V / 1 / 31.3 240V / 1 / 37.5 240V / 1 / 43.8 240V / 1 / 50.0 Commercial units are available in Bronze, Silver and Elegance packages 31 Trouble Shooting STEAMCORE WARNING! SEVERAL POWER SUPPLY. CHECK THAT THERE IS NO CHARGE IN THE MACHINE BEFORE DOING ANY MAINTENANCE WORK! Checking and fault-finding. In the e vent of faulty operation, f irst check the f ollowing: •are the contr ol panel and st eam generat or wired up in accor dance with the wiring diagram? •is the st eam generat or correctly installed in accor dance with these instructions? •does the drainage pipe slope do wn pr operly t owards the drain? •is the f ilter clogged? The f ilter is locat ed at the point where incoming w ater is fed into the generat or. T o clean the f ilter, disconnect the f eed pipe, rinse it free fr om par ticles of calcium carbonat e and o ther deposits. •are there an y sharp bends in the st eam pipe? (the minimum permitted radius of bends is 50 mm, 2") •If there is a tap on the w ater supply t o the st eam generat or, make sure this is no t closed. Checklist with alternative causes of pr oblems and suggest ed actions. Loud noises in the feed pipes when the solenoid valve opens or closes. Cause: The st eam generat or feed pipes are no t sufficiently secure. Solution: Fix the pipes securely t o the w all with pipe clips. Cause: “Recoil” problems in the f eed pipe (Pipe hammer). Solution: R eplace a metre-long length of piping nearest the steam generat or with fle xible piping, f or exam ple, reinf orced rubber hosing, which will withstand the pressure. The steam room requires an abnormally long time to heat up. Cause: The generat or is no t powerful enough. See table. Solution: R eplace the st eam generat or with one with a higher heat output. Cause: Ex cessiv e ventilation in the st eam room. Solution: R educe the v entilation to evacuate 10–20 cubic metres (1 3–26 cub. yd) of air per per son per hour . Cause: Blo wn fuse in the main fuse bo x. Solution: R eplace the fuse. Cause: The ambient t emperature is lo wer than 15°C (59 °F). Solution: Increase the ambient t emperature or replace the steam generat or with a more po werful one. Cause: Heating element is br oken. Solution: R eplace element. Cause: The thermostat sensor is t oo close t o the st eam jet. Solution: Mo ve the sensor or change the direction of the steam jet. Hot water runs from the steam head. Little or no steam in the steam room. Cause: The solenoid v alve for incoming w ater has stuck, due to accumulat ed deposits of f oreign bodies or an electrical malfunction. Solution: R emove the v alve and clean it, or rectify the electrical malfunction. Cause: The solenoid v alve is br oken. Solution: R eplace the v alve. Cause: Malfunction in the cir cuit boar d. Solution: R eplace the cir cuit boar d. Cause: The contr ol panel is incorrectly set. Solution: Check the time and t emperature on the contr ol panel. Cause: The f ilter is clogged. Solution: R emove the filter which is placed in the connection for incoming w ater. Clean of f any metal f ilings or o ther foreign bodies. Cause: The solenoid v alve for w ater supply has stuck . Solution: R emove the solenoid v alve and clean of f any metal filings or o ther foreign bodies. Cause: Ex cessiv e calcium carbonat e deposits in the st eam generat or’s w ater reser voir. Solution: R eplace the entire w ater reser voir, including heating elements and electr odes. Cause: The st eam generat or is wired up f or the wr ong v oltage. Solution: Check the v oltage and the connection t o the generat or – see diagram. Cause: The t emperature limit contr ol has been triggered, Solution: Check and remedy an y faults on the st eam pipe, such as a block age due t o se veral sharp bends, w ater pock ets or greatly reduced int ernal diamet er. The tank ma y also be clogged with limescale. Cause: Fla w in the cir cuit boar d, contr ol panel or magnetic contactor. Solution: R eplace the f aulty com ponent. Temperature cut-o off is activated. Cause: The st eam pipe is block ed. Solution: R emove the block age. Cause: The int ernal diamet er of the st eam pipe is considerably reduced. Solution: R eplace the pipe or the pipe joint which is causing the reduction (Int ernal diamet er must be at least 12 mm, ½"). Cause: Sharp bends ( “elbows”) along the st eam pipe. Solution: Get rid of “elbows” in the pipe. Bends are t o be gently r ounded (minimum radius 50 mm, 2"). Cause: Large w ater pock et some where along the st eam pipe. Solution: A djust the steam pipe t o eliminate the w ater pock et. Cause: Ex cessiv e calcium carbonat e deposits in the st eam generat or’s reser voir. Solution: R eplace the entire reser voir, including elements and electrodes. The steam room maintains the desired temperature (40–50°C, 105–122°F), but no steam is produced. Cause: Insuf ficient v entilation in the st eam room. Solution: Increase v entilation. The v entilation is insuf ficient if less than 1 0–20 cubic metres (1 3–28 cub. yd) of air per person per hour is e vacuated via the outlet v ent. This situation ma y occur if the outlet v ent is no t connect ed to some f orm of mechanical e xtractor fan – or if the v entilation duct is block ed by a w ater pock et. (Commer cial applications) Cause: The air coming int o the st eam room is t oo w arm. Solution: R educe the intak e air temperature to 35°C (95 °F). Cause: The ambient t emperature is higher than 35 °C (95 °F). Solution: Ensure that the ambient t emperature does no t exceed 35°C (95 °F). Cause: The thermomet er is faulty or wr ongly placed. Solution: The thermomet er should be placed appr oximately (72") abo ve floor le vel and as f ar away from the st eam jet as possible. Hot water comes out of the steam head in spurts or in a slight, even flow mixed with steam. Cause: Small w ater pock et along the st eam pipe. Erratic steam production right from the start. Cause: The thermostat sensor is wr ongly placed in relation t o Solution: Eliminat e the w ater pock et. Cause: The st eam pipe is uninsulat ed along t oo great a the steam jet. portion of its length. Solution: Mo ve the sensor or alt er the direction of the st eam Solution: Insulat e the st eam pipe. A continuous trickle of ho t jet. Cause: Calcium carbonat e or o ther foreign bodies in the f ilter. water from the st eam generat or’s drainage pipe. Cause: The solenoid v alve for automatic em ptying has stuck . Solution: R emove and clean the f ilter. Solution: Switch of f the steam generat or. See what happens again af ter an 80-minut e pause. If the f ault persists, remo ve Neither steam nor heat is generated in the the solenoid v alve for the aut omatic em ptying function and steam room. clean it. Cause: Blo wn fuse in the mains fuse bo x. Solution: R eplace the fuse. Cause: The w ater is no t reaching the st eam generat or. Solution: Open the tap(s) connect ed to the piping t o allow incoming w ater to flow into the st eam generat or. 32 33 3 www.saunacore.com User Manual Common trouble shooting methods To facilitate your use and maintenance of sauna room, the following common trouble shooting methods are listed for reference. Troubles Causes of troubles Trouble-shooting methods The machine does not start when electrified 1.The fuse is burned. 2.The wire connection terminal becomes loose. 3.Not good contact in the connection wire between the controller and the steam engine. 1.Change the fuse (on the shell 0.8A/ 250V) 2.Plug tight the wire connection terminal 3.Make sure the steam engine and the controller come into good contact Electricity leakage switch breaks automatically 1.The wire connector is dampened or damaged. 2.The heating tube breaks 1.Check whether the wire connector is dampened or damaged, and dry with dryer if dampened. 2.Change a heating tube. When the machine is started, hot water 1. The water drainage valve is broken. comes out with little or no steam 1. Change a water drainage valve. The display screen on the control panel does not display 1.The power wire is not connected well 1.Check whether the connection plug between or not in good contact. The connection the control panel and the electricallyplug between the control panel and the controlled box has become loose, and electrically-controlled box becomes whether the power circuitry has good contact. loose. 2.Change a plugboard. 2.Trouble with plugboard. Water leakage 1.The water pipe connector becomes loose or the pipe breaks 2.Water leakage in the water input valve or the waterdrainage valve 1.Tighten the loose connector, and change the broken pipe. 2.Change the water input valve or the water drainage valve. No steam when starting the machine 1.No electricity. 2.No water. 3.The set temperature is too low 4.Troublewithwire. 1.Check the power supply 2.Check the water input pipe and water input valve 3.Reset the temperature 4.Contact the distributor The steam does not come out, the water 1. The steam pipe is jammed. sounds in the machine 1. Cut power supply to check whether the steam pipe is smooth. The light can not be turned on 1. The fuse is burned. 2. The light is broken 3. The wire is broken 4. The plug does not have good contact 1.Change the fuse (on the shell 1A/250V) 2. Change a light bulb. 3. Change wire. 4. Make the contact good. The display box displays normally with no steam input 1.Too much pressure inside the steam engine, so the system breaks for heat protection. 2.Wire is broken for heat protection. 1.Check the steam transport pipe and restore automatically after heat protection becomes cool. 2.Check the heat protection wire to make sure the connection is good. Technical Hotline 905-951-6662 33 Steambath Generator Limited Warranty STEAMCORE Pro-Series Steambath Generator Limited Warranty Saunacore warrants these products to be free from defects in material and workmanship and agrees to remedy any such defect. This warranty does not apply outside the boundaries of the United States or Canada, or to any product which in our sole opinion has been improperly installed, or subject to willful abuse, misuse, alteration, and shipping damages during the period of coverage. Postage and handling charges of the product to and from Saunacore for warranty repairs and for any related charges for the installation / removal of these products are NOT included in your warranty. Warranty service can be obtained by sending your product to Saunacore (Call 905-951-6662). Warranty repairs must be done only by Saunacore. Proof of purchase and a serial number of the product will be required before any services are performed. Warranty applies only to the original consumer purchaser, warranty is non-transferable. For warranty repair, the steam generator must be returned to Saunacore with an Return Materials Authorization is to be obtained by the original consumer purchaser and must be shown on all correspondence and packaging, without this RMA # returns for repairs will NOT be accepted. Warrranty is non-transferable from original consumer purchaser. Current warranty claim fee effective 01/01/07. Controls & Cables: One Year Parts and Labor Steam Generator: First Years Parts & Labour. Second Year to Fifth Year Warranty Claim Fee (Admin/ Deductible Fee) $150.00 (Note: Warranty does not apply to damages caused by Calcium, Lime Stone build up or corr osion to the steam generator). OPTION (Commercial Steamer Maintenance): commercial Steambath Generator, there is a ser vice charge of $500.00 per y ear due at the beginning of every year. This cost will include 2 maint enance services per y ear for your Steamer , including par ts, repair s and labour. ______________________________________________________________ Warranty Registration Card Model # ____________________________________ Serial # __________________________________ Purchase Date ________________________________________________________________________________ Dealer Name and Adress ____________________________________________________________________________________________ Owner Name and Address ____________________________________________________________________________________________ NOTE: A COPY OF THE RECEIPT MUST ACCOMPANY THIS WARRANTY CARD. ">
Advertisement
Key Features
- Automatic rinse and flush
- Inline filter
- Easy operation
- Minimal maintenance
- High quality
Frequently Answers and Questions
Can I install the steam generator inside the steam room?
No, you must install the steam generator outside of the steam room.
What kind of piping can I use for the steam line?
You must use brass or copper tubing. Do not use black, galvanized or PVC pipe.
What if the water level control circuit needs service?
The main circuit breaker should be switched off immediately and kept off until the problem has been corrected.