1. INTRODUCTION

The conversion of electrical power is an essential requirement for export testing or operation of equipment brought to the U.S. from abroad. The KSS series Frequency

Converter is designed to meet these needs as it supplies reliable, pure and stable power at an affordable price.

This Converter is designed with the following unique features l Double Conversion IGBT module, Single control board design, eliminates adjustment, and minimizes maintenance. l LCD display for unit status, user friendly design l Special overload capacity design, 150% overload for 30 sec. l Built-in isolation transformer to ensure total isolation between the input and output. l Special airflow control to avoid dust accumulation. Suitable for any rough operating environments. l Compact size, light weight.

1

2

2.2

LED Explanation

(Refer to Image on previous page)

1. LINE: (Green LED) When this LED is lit, it indicates that the AC Line input voltage (either 120VAC or

220VAC, depending on connection) is connected, the breaker is set to the ‘on’ position, and voltage is being applied.

2. BYPASS: Not Applicable

3. INV.: (Green LED) After a 10 second (approximate) internal startup delay, this LED lights to indicates that the unit is converting the frequency to the specified parameters (60 to 50, 50 to 60, et al).

4. BATT.: Not applicable, unless optional battery backup has been ordered.

5. LOAD: (Amber LED) When the load % (accessible for view through the LCD screen) reaches 120% (and over), the unit beeps, and this LED lights to alert the operator of an overload condition.

6. FAULT: (Red LED) When this LED is lit, it indicates that there is an internal problem, please contact

Visicomm for further information, and instructions.

3

4

Input Power Connections and Grounding

S ystem Ground Connection:

The Earth Ground should be provided by the utility. This is normally the “GREEN” wire provided by the utility which at some point is routed to a secure earth ground such as a water pipe. This wire should be connected to the screw post marked GND on the Converter (See photo for location).

Note that there are no internal electrical connections to this wire with the exception of a small high frequency bypass capacitor for RF suppression. Therefore, the function of the Earth

Ground is simply to maintain the case of the Converter at ground potential. Visicomm Industries

(LLC) does not recommend any other connection to the Earth Ground wire which may introduce significant amounts of current and thereby defeat the intended purpose of this wire which is the safety of the operating personnel. In particular, do not connect this wire to the system neutral wire at any point.

Output Connection:

The Power OUTPUT Connections are provided by three barrier terminal posts labeled N,

L1, and L2. These three terminals constitute the three terminals of an internal auto-transformer were L1 is the “center tap”. This is fed by the output winding of a switching transformer. Since the only other internal connections are a resonating capacitor, the cooling fans, and sensing circuits( to maintain an output sine wave ), these output terminals are electrically isolated from any other circuits including the system neutral.

The Converter is shipped with these OUTPUT connections electrically isolated. If a digital voltmeter is connected between any one of these OUTPUT terminals and the Earth Ground, a significant voltage reading will be obtained. This voltage is due to a small leakage current and is not considered a problem since only 1 or 2 ma is involved.

Output Isolation:

Many applications require an isolated output, primarily for safety reasons, when supplying power to a device under test especially if there will be other monitoring equipment connected to the device. Other applications can take advantage of the low leakage current of the Converter

(about 1 or 2 ma). This can be useful in systems where the individual leakage currents of the components might exceed the allowed leakage current of a ground fault interrupter.

Other applications require that the output have a connection to the utility NEUTRAL.

Normally this would be OUTPUT terminal N (The exception would be a two phase output where

L1 would be the connection to the system NEUTRAL). The Converter is supplied with a short jumper wire. If the system NEUTRAL is used to power the INPUT terminals and it is required that the OUTPUT be connected to NEUTRAL this jumper can be employed to make this connection.

If the INPUT is supplied by two phase AC or by two phases of a three phase system (in other words, if you have only two incoming power wires), this NEUTRAL would not be present and an external wire from the desired OUTPUT terminal to the system NEUTRAL would be required. See INPUT CONNECTION DIAGRAM on next page.

N

L1

L2

Basic diagram of output stage

5

INPUT POWER CONNECTIONS

The frequency of the input power can be 50 or 60 Hz, and is not related to the output frequency

CAUTION:

The Input is Electrically Isolated from the output.

It is necessary to connect the input using one of the following four methods.

A. SINGLE PHASE 220V INPUT

This connection is usually used in 50Hz countries where a neutral is normally available.

B. SPLIT PHASE 220V INPUT

This connection is usually used in 60Hz countries where a 220V line is not normally available, and where the input amperage makes using 120V inconvenient.

C. SINGLE PHASE 120V INPUT

D. THREE PHASE 120/208 VAC USING LINE TO LINE INPUT

To be used if the 120V line to neutral connection is limited by the amperage available.

6

OUTPUT POWER CONNECTIONS

The frequency of the output power can be 50 or 60 Hz, and is not related to the input frequency

CAUTION:

The output is "floating" and is electrically isolated from the input.

It is necessary to connect the output using one of the following three methods.

Note that these output voltages are widely adjustable using the voltage adjust rheostat.

A. SINGLE PHASE 120V OUTPUT

B. SINGLE PHASE 220V OUTPUT

C. SPLIT PHASE 220V OUTPUT

7

Model

Capacity

4. SPECIFICATION

2KSS6050/5060

2KVA /1.4kW Input Current Requirement @ 220V, 10.3A –120V, 19.1A

Input

Voltage

Voltage Range

Frequency

Phase

120 or 220VAC

120V –15%/+20% or 220V –15%/+20%

50 Hz or 60 Hz ± 5%

Single

Output

Voltage

Voltage Regulation

Frequency

Frequency Regulation

Harmonic Distortion

Output Waveform

Output Current @ .7pf

Non-Linear Peak Current

120 or 220VAC ± 20%

± 1 %

50 Hz or 60 Hz (400Hz available)

± 0.0004% (xtal oscillator)

< 3% at 100% Linear Load

Pure Sinewave

120V-16.6A, 220V-9A

120V-24.6A, 220V-13.5A for 30 sec.

Power Factor

Efficiency

0.7

AC to AC > 85%

Protection

Overload Capacity

Short Circuit

EMI Filter

Over Temperature

110%continuous, 110-150% load 30 seconds, over 150% causes unit to shut down. Auto restart upon removal of overload

Unit will cut out and must be manually restarted

10-100KHz at 40dB, 100KHz-100MHz at 70dB

In verter auto cut-off when heat sink temp. over 80ºC.

Audible Alarm

Overload

Converter Fault

Sounds continuously

Sounds continuously

Indicators

LCD

LED

Converter status, INPUT & OUTPUT voltage- frequency, loading %

Line: Green LED

Fault: Red LED

In verter: Green LED

Overload: Yellow LED

Environment

Operation Temp.

Relative Humidity

Audible Noise

-10ºC to 50 ºC; 14ºF to 122ºF

20-90% non-condensing

<45dB

Physical

Dimensions

Net Weight

Depth

Width

Height

144lbs / 64.8kg

21.75in / 55.25cm

7in / 17. 78cm

19in / 48.26cm