User`s Manual

Add to my manuals
38 Pages

advertisement

User`s Manual | Manualzz

User's Manual

Version:V0.02

User’s Manual

INNO Instrument, Inc.

Table of Content

Introduction....................................................................................................................................4

Chapter l Technical Specifications.................................................................................................5

Applicable Fiber Type....................................................................................................................5

Splice Loss....................................................................................................................................5

Splice Mode...................................................................................................................................5

Heat Oven.....................................................................................................................................5

Power Supply.................................................................................................................................6

Dimensions and Weight.................................................................................................................6

Environment...................................................................................................................................6

Other..............................................................................................................................................6

Warnings For Batteries......................................................................................................6

Chapter 2 Installation.....................................................................................................................7

Safety Warnings and Cautions......................................................................................................7

Safety Warnings............................................................................................................................7

Maintenance and External Care Precautions.................................................................................8

Transport and Storage Precautions...............................................................................................8

Installation.....................................................................................................................................8

Unpacking the Splicer...................................................................................................................8

Splicer Description and Functions.................................................................................................9

Power Supply...............................................................................................................................10

AC adapter..................................................................................................................................10

Chapter 3 Basic Operation...........................................................................................................11

How to Install Cleaving Table.......................................................................................................11

Turning splicer "ON"....................................................................................................................12

Adjust the Angle of Monitor .........................................................................................................12

Adjust the LCD Monitor Brightness.............................................................................................13

Preparing the Fibers...................................................................................................................13

PAGE 01

User’s Manual

INNO Instrument, Inc.

How to Make a Splice...................................................................................................................14

Setting Fiber in the Fiber Holder...................................................................................................14

Inspecting the Fibers....................................................................................................................14

Splice...........................................................................................................................................15

How to Protect the Splicing point..................................................................................................15

Heating Procedure.......................................................................................................................15

Chapter 4 Splice Programs..........................................................................................................17

Displaying the Active Splice Program...........................................................................................17

Selecting a Splicer Program.........................................................................................................18

General Splicing Steps................................................................................................................19

Prefusion......................................................................................................................................19

Fusion.........................................................................................................................................19

Splicing Process..........................................................................................................................19

Standard Mode............................................................................................................................20

Chapter 5 Splice Option...............................................................................................................21

Setting Parameters.....................................................................................................................21

Chapter 6 Heater Mode................................................................................................................22

Selecting Heater Mode.................................................................................................................22

Editing Heater Mode....................................................................................................................23

Erasing a Heater Mode...............................................................................................................24

Heater Mode Parameters.............................................................................................................24

Chapter 7 Maintenance Menu......................................................................................................25

Replace Electrodes.....................................................................................................................25

Replacement Procedure..............................................................................................................25

Stabilize Electrodes....................................................................................................................26

Operation Procedure...................................................................................................................26

Diagnostic Test Function..............................................................................................................26

Operation Procedure...................................................................................................................26

PAGE 02

User’s Manual

INNO Instrument, Inc.

Dust Check..................................................................................................................................27

Operation Procedure....................................................................................................................27

Motor Calibration..........................................................................................................................27

Operation Procedure....................................................................................................................27

Arc Calibration.............................................................................................................................27

Operation Procedure....................................................................................................................28

Electrode Setting..........................................................................................................................28

Software Upgrading.....................................................................................................................28

Chapter 8 Other Function & Utilities.............................................................................................29

Data Storage ...............................................................................................................................29

Display Splice Record..................................................................................................................29

Clearing Splicing Results in Memory............................................................................................29

Cancel Data Storage....................................................................................................................29

System Setting.............................................................................................................................29

Change Monitor Position..............................................................................................................30

Power Save..................................................................................................................................31

System information......................................................................................................................31

Appendix Ⅰ.................................................................................................................................32

Appendix Ⅱ.................................................................................................................................33

Appendix Ⅲ.................................................................................................................................35

PAGE 03

User’s Manual

INNO Instrument, Inc.

Introduction

Thanks for choosing IFS-18 High precision fusion splicer from INNO. The IFS-18 with innovative design and exquisite manufacturing technology bring customers unprecedented splicing experience.

New technology greatly reduce splicing and heating time. Advanced estimate method and core alignment technique ensure the accuracy of splice loss estimation.

Its small size, compact design and reliable protection shell make it suitable for any operating environment. Dynamic operation interface and automatic splice mode give the customers great convenience.

For more information on IFS-18, please visit our web www.innoinstrument.com

Model: FH-18

Universal Fiber Holder specialized for factory

This manual explains the features, specifications, operation, maintenance and warnings about IFS-18. The primary goal of this manual is to make the user be familiar with the splicer as soon as possible.

Important!

INNO Instrument recommends all users to read this manual carefully before operating IFS-18.

PAGE 04

User’s Manual

INNO Instrument, Inc.

Chapter 1-Technical Specifications

Applicable Fiber Type

* SM(ITU-TG.G652) l MM(ITU-TG.651)/DS(ITU-TG.653)/NZDS(ITU-TG.655)/

ITU-TG.657/HP980/HI1060/HI1060FLEX/SM0.08mm

* Fiber count: Single

* Applicable fibers:

0.08mm/0.125mm/0.25mm/0.9mm

* Applicable fiber diameter: Cladding diameter: 80-150μm, Coating diameter:

100-1000μm

Splice Loss

Measured by cut-back method relevant to ITU-T standard

* SM: 0.02dB

* MM: 0.01dB

* DS: 0.04dB

* NZDS: 0.04dB

* G.657: 0.02dB

Splice Mode

* Preset 42 splice modes

* Internal splice data storage: 2000

* Splicing time: SM FAST mode: 7s

Heat Oven

* Applicable protection sleeve:

20mm, 30mm, 40mm, 50mm, 60mm

* Heating time: 20-900s

* Cooling time: 0- 180s

* Typical heating time: 35s

* Heater mode: 32 heat modes, preset 5 heat modes

* Heat oven: IFS-18 Special Heat Oven

PAGE 05

User’s Manual

INNO Instrument, Inc.

Power Supply

* Input power: AC 100-240V, 50-60HZ.

* Li-ion battery input: DC 9~14V.

Dimensions and Weight

* Size: Length x Width x Height = 160mm x 145mm x 148mm

* Weight: 2.15 kg (AC adapter included) 1.9kg

Environment

* Operating condition: 0-5000m above sea level, 0-95% relative humidity,

-10-50℃ . 15m/s wind.

* Storage condition: 0-95% relative humidity, -40-80℃ ; Battery: -20-30℃ for

long time storage.

Other

* Viewing Method: two camera and 5.0 inch color LCD monitor.

* 300x magnification for single X or Y view, or 180x for both X and Y view.

* Mechanical proof test: 1.96- 2.25 N.

* Terminals: USB2.0 for upgrading.

Warnings For Batteries

1) Never strike batteries with any sharp edge parts.

2) Never transport or store batteries together with the metal content.

3) Never throw, drop, impact or bend battery body. Never knock the battery with the hammer nor thread on it.

4) Never short-circuit the battery by connecting the positive and the negative terminal with metal content like wires.

5) Never make the positive or negative terminals in touch with the aluminum backing of polymer-aluminum packaging material, it will make the battery short circuit.

6) Do not disassemble the battery Cells in any event.

7) Never dip battery into the water or seawater, the cells should be keep from moisture.

8) Never use or leave the battery near a heat source as fire or heater.

9) Never apply direct heat to the battery or put it into the water.

10) Never directly solder the battery.

11) Never charge batteries near the fire or in a hot environment.

12) Never put batteries into the microwave oven or any high pressure vessel.

13) Avoid long-term use of the battery or leave it at high temperature (for example, in the strong sunlight or inside your car in extreme temperatures), otherwise it will cause the battery be overheated, on fire, function decline or its service life be decreased.

14) Never use the damaged battery. The battery which electrolyte was leaked or there's a smell of electrolyte should be far away from fires to avoid the battery on fire or explode.

15) In case the electrolyte was leaked and came into contact with the skin or any other parts of the body, rinse immediately with clear water. If the electrolyte come into contact with the eyes, see a doctor nearby after rinsing with clear water.

PAGE 06

User’s Manual

INNO Instrument, Inc.

Chapter 2 - Installation

Safety Warnings and Cautions

As IFS-18 is designed for fusion splicing silica glass optical fibers, it is very important that the splicer should not be used for any other purpose. The splicer is a precision instrument and must be handled with caution. Therefore, you must follow all safety rules and general precautions in this manual. Any behavior that not follow the warnings and cautions will break the safety standard about the fusion splicer and may result in electric shock, fire, and/or serious injury. INNO will not take the responsibility for those results caused by misuse!

Safety Warnings

① Never operate the splicer in an environment where flammable liquids or vapors exist.

② Do not touch the electrodes when the splicer is on and power is supplied to the unit. The electrodes

generate high voltage and high temperatures that may cause a severe shock or bum.

③ Do not disassemble or modify the splicer, AC adapter, battery or battery charger. In particular,

do not remove or bypass any electrical or mechanical device (e.g. a fuse or safety switch)

incorporated into the design and manufacture of this equipment. The equipment must be

repaired or adjusted by an authorized technician or engineer. Unauthorized repair may result in

fire or electric shock.

④ Properly connect the AC power cord to the splicer(inlet) and wall socket (outlet). When inserting

the AC plug, make sure there is no dust or dirt on the terminals. Engage by pressing the female

plug into the splicer (inlet) and the male plug into the wall socket (outlet) until both plugs are fully

seated. Incomplete engagement may cause fuming, electric shock, or equipment damage and

may result in injury, death, or fire.

⑤ Never operate the splicer in an environment where flammable liquids or vapors exist. Risk of

dangerous fire or explosion could result from the splicer's electrical arc in such an environment.

Do not operate splicer near hot objects, in high temperature environments, in dusty/humid

atmospheres, or when water-condensation is present on the splicer. This may result in electric

shock, splicer malfunction, or poor splicing performance.

⑥ Safety glasses should always be worn during fiber preparation and splicing operation. Fiber

fragments can be extremely dangerous if they come into contact with the eye, skin, or are

ingested.

⑦ Disconnect the AC power cord from the AC adapter inlet or the wall socket (outlet) immediately

if user observes the following or if the splicer receives the following faults:

- Fumes, bad smell, noise, or over-heating occurs.

- Liquid or foreign matter falls into cabinet.

- Splicer is damaged or dropped.

If any of these faults occurs, ask our service centre for repair. Leaving the splicer in a damaged

state may cause equipment failure, electric shock, or fire and may result in injury or death.

⑧ Do not use compressed gas or canned air to clean the splicer. They may contain flammable

materials that could ignite during the electrical discharge

⑨ Use only the AC adapter designed for this splicer. Using an improper AC power source may

cause fuming, electric shock, or equipment damage and may result in injury, death, or fire.

Proper AC power source is AC 100~240v, 50~60Hz. Check the AC power source before use.

⑩ Use the supplied AC power cord. Do not place heavy objects on the AC power cord. Keep the

power cord away from heat source. Use of an improper cord or a damaged cord may cause

fuming, electric shock, or equipment damage and may result in injury, death, or fire.

PAGE 07

User’s Manual

INNO Instrument, Inc.

Maintenance and External Care Precautions

① Always avoid using hard objects to clean V-grooves and electrodes.

② Do not use any chemical other than pure alcohol (99% or greater) to clean the

objective lens, V-groove, LEDs, LCD monitor, etc., of the splicer.

③ Use a dry cloth to remove dust and dirt from the splicer.

④ If the outside of the splicer is dirty, plunge a soft cloth into diluted neutral

washing up liquid, wring out the cloth and clean. Dry the splicer with a dry cloth

but DO NOT use furniture polish or other cleaning agent.

⑤ Always follow the maintenance instructions in this manual.

Transport and Storage Precautions

① When the splicer is moved from cold to warm environment, you should allow the splicer to warm up gradually. Otherwise, the condensation generated inside will be harmful for the splicer.

② Pack the fusion splicer for long time storage.

③ Keep the splicer clean and dry.

④ The fusion splicer is precision adjusted and aligned. Always keep the slicer in its carrying case to protect from damage and dirt. Put cushion package outside the carry case for long distance transporting.

⑤ Always avoid leaving the splicer in direct sunlight or expose to excessive heat.

⑥ Do not store the splicer in dusty/humid atmospheres. This may result in electric shock, splicer malfunction, or poor splicing.

⑦ Keep the humidity to a minimum level where the splicer is stored. The humidity must not exceed 95%.

Installation

Important!

Please carefully follow the instructions below.

Unpacking the Splicer

Check the belt and hooks for damage before taking the splicer out.

Lift the splicer by the lifting belt as show below:

PAGE 08

Power ON/OFF

User’s Manual

INNO Instrument, Inc.

Splicer Description and Functions

Operating button

Heat oven

Lifting belt

Monitor AC adapter

USB port

Serial port

AC adapter interface

PAGE 09

User’s Manual

INNO Instrument, Inc.

Power supply

AC adapter

1. Installation diagram is shown as follow.

Release button

Take out AC adapter

Power off the splicer.

Press the release button and take out the AC adapter.

2. The connection diagram is shown as follow.

Inserting the AC adapter into the power unit dock until you hear "click".

PAGE 10

User’s Manual

INNO Instrument, Inc.

Chapter 3 - Basic Operation

How to Install Cleaving Table

Fix the cleaver on the Cleaving Table by matching screw.

PAGE 11

User’s Manual

INNO Instrument, Inc.

Turning Splicer "ON"

Press "POWER" button on the operation panel. The ready screen is displayer after the motors rest to their initial positions.

Adjust the Angle of LCD Monitor

Adjust the monitor angle to comfortably watch the screen.

PAGE 12

User’s Manual

INNO Instrument, Inc.

Adjust the Monitor Brightness

In the initial interface, press "←" or "→" to change the monitor brightness until it is clear enough.

Preparing the Fibers

3 steps for preparing fibers:

Step 1: Strip the fiber

① Remove at least 50mm of secondary coating (valid for both tight and loose tube secondary coating) with an appropriate stripper.

② Remove approximately 30mm of primary coating with an appropriate stripper.

Step 2: Clean the fiber

Clean the bare fiber thoroughly with alcohol impregnated gauze or lint-free tissue.

Step 3: Cleave the fiber

Cleave the fiber by high precision fiber cleaver.

In order to get excellent splice result, high precision fiber cleaver should be used, such as

INNO VF- fiber cleaver. And the cleave length also should be precisely controlled (shown below).

From this point, you must be very careful with the fibers to ensure that they do not become dirty again.

- avoid putting them down on a dusty working surface

- avoid waving them around in the air.

- check if the V-grooves are clean, if not, wipe them clean

- check if the fiber clamps are clean, if not, wipe them clean

PAGE 13

User’s Manual

INNO Instrument, Inc.

How to Make a Splice

Setting Fiber in the Fiber Holder

① Open the wind shield.

② Raise the fiber clamps.

③ Place the fibers into V-grooves.

④ Make sure the fiber ends are visible on the monitor.

(4a) If the fiber ends are not visible, the splicer will try to find them by moving the fibers horizontally. The ends will be found if the fibers are placed within the mechanical movement range of the horizontal motors.

(4b) If not, an error message will be displayed. The splicer will not find fiber ends that are placed above or below the imaging area.

(4c) Normally, this should only happen if the V-grooves or the fibers are dirty, or if the splicer is not well adjusted.

⑤ Clamp the fiber in position by lowering both sets of fiber clamps.

⑥ Close the safety shield.

Inspecting the Fibers

Make sure the fibers are clear and be well cleaved before you proceeding the splice.

If you find any defects as illustrated above, remove the fibers and prepare again.

PAGE 14

User’s Manual

INNO Instrument, Inc.

Note: The fibers are checked automatically when you press "Set" button. The splicer automatically focuses the fibers and checks for damage or dust particles.

① Select the appropriate splicing mode.

② Press "SET" to start splicing.

Splice

How to Protect the Splice

After splicing, protect the joint by using a heat-shrink sleeve and the heat oven which is mounted onto the splicer.

Heating Procedure

① Open the heat oven lid.

② Lift the left and right fiber clamps on the splicer.

Holding the heat-shrink tube (previously placed onto the fiber), lift the spliced fibers and holding them taut, move the heat-shrink tube so that it is centered over the splice point.

③ Move both the fibers and the heat-shrink tube over to the heat oven and place them in the oven clamps.

④ Press "HEAT" to start. After heating, the led indicator will go out with buzzing.

PAGE 15

User’s Manual

INNO Instrument, Inc.

Opening the heater lid Splice

Moving the fibers and protection sleeve to the heat oven.

Heating Indicator Heat Button

PAGE 16

User’s Manual

INNO Instrument, Inc.

Chapter 4 - Splice Programs

IFS-18 has an intuitive and simple, but very powerful program structure. Splice programs define arc currents, splice times as well as various parameters used when performing a splice. Therefore, it is essential to select the correct splice program in accordance with the type of fiber you want to splice.

There are a number of "pre-defined" splice programs for common fiber combinations (see below). However, it is also easy to either modify or write new splice programs to further optimize the parameters for more unusual fiber combinations. (These are known as "user-defined" programs.)

Displaying the Active Splice Program

The active splice program is always displayed at the top of the screen (see below).

The splicer uses this program when you press “confirm” in Main menu:

Displaying the Active Splice Program

PAGE 17

User’s Manual

INNO Instrument, Inc.

选择熔接模式

① Select "Splice Mode" from the "Main menu".

② Select appropriate splice program.

③ Select the splice mode you want.

④ Press "RESET" return to the initial interface to check the selected splice program.

PAGE 18

User’s Manual

INNO Instrument, Inc.

General Splicing Steps

This section explains the steps involved in automatic splicing process and describes how various program parameters are related to this process. The normal splicing process can be divided into two sections; prefusion and fusion.

Prefusion

During prefusion, the splicer performs automatic alignment and focusing, where the fibers are subjected to a low prefuse current for cleaning purposes; a prefuse image is also taken. At this point, the user is informed of any problems recognized in the prefuse image, such as a poorly prepared fiber. The splicer will then issue a warning before the fibers are fused together.

Fusion

During fusion, the fibers are joined together and subjected to five different currents as illustrated below. An important parameter, which changes during splicing, is the distance between the fibers. During Pre-fusion, the fibers are apart. With the current phase changing, fibers are splicing gradually.

Splicing Process

Arc power and Arc time are considered the two most vital parameters. How those parameters affect the splicing process will be described in next section "Splice option".

Below is a figure showing the arc discharge conditions (relationship between

"Arc power" and "Motor motion"). These conditions can be edited by changing the splicing parameters listed below. Depending on the splice mode, certain parameters cannot be changed.

PAGE 19

User’s Manual

INNO Instrument, Inc.

Standard Mode

PAGE 20

User’s Manual

INNO Instrument, Inc.

Chapter 5 - Splice Option

Setting Parameters

① Select [Splice Option] in "main menu".

② Click your item and change the parameter.

PAGE 21

User’s Manual

INNO Instrument, Inc.

Chapter 6 - Heater Mode

There are 32 heating modes and preset 5 heating modes by INNO factory. The others could be defined by users. Select the one best suited for the protection sleeve used.

For each type of protection sleeve, IFS-18 has its optimum heating mode. These modes can be found in the database area for reference. Copy the appropriate mode and paste it to the user-programmable area. The operator can edit the userprogrammable modes.

Selecting Heater Mode

Select "Splice mode" and then enter the "Heating mode" menu.

① Select [Heating Mode] menu from "main menu".

② Select [Select Heater

Mode] menu.

PAGE 22

User’s Manual

INNO Instrument, Inc.

③ Select the heater mode.

④ Press "RESET" to return to the initial interface to check the heater mode selected.

Editing Heater Mode

Tube-heating conditions stored in heater mode can be edited or changed.

(1) Select [Edit Heater

Mode] through [Heater

Mode] menu.

(2) Select the mode to be edited.

PAGE 23

User’s Manual

INNO Instrument, Inc.

(3) Select the parameter to be changed, and edit it.

Erasing a Heater Mode

① Enter [Heating Mode] menu.

② Select [Delete Heater Mode].

③ Select the heater mode to delete.

Note: The mode shown in gray (20mm, 30mm) is the system default initial mode and could not be delete.

PAGE 24

User’s Manual

INNO Instrument, Inc.

Chapter 7 - Maintenance Menu

The splicer has a function to perform routine maintenance. This section describes how to use the maintenance menu.

(1) Press "menu" button, select [maintenance menu].

(2) Select a function to perform.

Replace Electrodes

During arc process, the oxide generated on the tips of electrodes. It is recommended that the electrodes should be replaced after 3,500 arc discharges.

When the number of arc discharges reaches a count of 3,500, a message prompting to replace the electrodes is displayed immediately after turning on the power. Using the electrodes without a replacement will result in greater splice loss and reduced splice strength.

Replacement Procedure

(1) Execute [Replace Electrodes] in [Maintenance Menu].

(2) Instruction messages will appear on the screen to turn off the power, then power off.

(3) Remove the old electrodes.

(i) Loosen screw located on electrode cover.

(ii) Take electrode out of electrode cover. (Electrode fits into electrode cover)

Loosen the screw Remove old electrode and install new one

(4) Clean the new electrodes with alcohol-impregnated clean gauze or lint-free tissue and install them in the splicer.

(i) Insert the electrode in the electrode cover.

(ii) Place the electrode cover on the splicer and tighten screw.

(5) INNO recommends all operators to do stabilizing electrodes and arc calibration after electrodes replacing to keep good splice results and splice strength. (Details will be described below. )

PAGE 25

User’s Manual

INNO Instrument, Inc.

Stabilize Electrodes

In the event of sudden change in environmental conditions or after cleaning electrodes, the arc power sometimes becomes unstable, resulting in higher splice loss. Especially when the splicer is moved from lower altitudes to higher altitudes, it takes time for the arc power to stabilize. In this case, stabilizing electrodes will expedite the process to set the arc power stable. If many tests are needed to get the “Test OK” message appears in [Arc Calibration], use this function as well.

Operation Procedure

(1) Select [Stabilize Electrodes].

(2) Load prepared fibers on V-groove of the splicer for splicing.

(3) Press SET and the splicer begins to stabilize the electrodes in the following ways:

* Repeats short arc discharge five times to measure the arc position.

* Performs [Arc calibration] to calibrate the arc power.

* Perform 20-cycle continuous discharge to stabilize the electrodes.

Diagnostic Test Function

IFS-18 has a built-in diagnostic test feature that allows the user to perform a simple one step evaluation of splicer performance covering several different critical variables. Perform this function in the event of splicer operation trouble.

Operation Procedure

(1) Select [Diagnostic Test ] in [Maintenance Menu].

(2) The following checks will be made.

PAGE 26

User’s Manual

INNO Instrument, Inc.

Dust Check

During normal splicing, the splicer observes fibers through image acquisition and processing. Dust or contaminants on the cameras and lenses disturbs normal observation of fibers and may result in improper splicing. This function checks the optical path for the presence or absence of contaminants and judges whether they cause trouble for fiber splicing.

Operation Procedure

(1) Select [Dust Check] in [Maintenance Menu].

(2) If fibers are set in the splicer, remove them and press "SET" button to start the dust check.

(3) If contamination is discovered during the process, the message "Find dust on the camera lens" will be displayed on the screen. Press back button two times, the location of contamination will shown on the screen. Clean the objective lenses and redo [Dust Check] until the message "Operation Completed" is displayed.

Note: If contamination still exists after cleaning the objective lenses, please contact with the agent.

Motor Calibration

Motors are adjusted at the factory before shipping. However, settings can be changed in various reasons. This function automatically calibrates the speed of all 6 motors.

Operation Procedure

(1) Select [Motor Calibration] in [Maintenance Menu].

(2) Load prepared fibers in the splicer and press SET button.

(3) Speeds for all motors are automatically calibrated. The message "Operation

Completed" will be displayed if the operation is completed.

Arc Calibration

Atmospheric conditions such as temperature, humidity, and pressure are constantly changing, which creates variability in the arc temperature. This splicer is equipped with temperature and pressure sensors that are used in a constant feedback monitoring control system to regulate the arc power at a constant level.

However, changes in arc power due to electrode wear and glass adhesion cannot be corrected automatically. Also, the center position of arc discharge sometimes shifts to the left or to the right. In this case, the fiber splicing position has to be shifted in relation to the arc discharge center. It is necessary to perform an arc power calibration to eliminate those problems.

PAGE 27

User’s Manual

INNO Instrument, Inc.

Operation Procedure

(1) Select [Arc Calibration] in [Maintenance Menu] to display Arc Calibration on the screen.

(2) Set prepared fibers on the splicer and press SET to execute arc calibration.

(3) After arc calibration, there are two values show on the screen. If the right value achieves

11±2, the message "Test Finished " will be display. Otherwise, multiple iterations of arc calibration are needed until the message "Test Finished" is displayed.

Electrode Setting

Set the electrode change warnings. INNO recommends that replace the electrodes every 3,500 discharge to keep perfect splice results.

(1) Select [Electrode Setting] in [Maintenance Menu] to display Setting Electrodes on the screen.

(2) Set Electrode Caution and Electrode Warning.

Software Upgrading

① Select [Update Software] in [Maintenance Menu].

② Connect the driver contains upgrading files to the USB port.

③ Press OK to upgrading automatically. The splicer will restart after upgrading.

PAGE 28

User’s Manual

INNO Instrument, Inc.

Chapter 8 - Other Functions & Utilities

Data Storage

This splicer stores up to 2,000 splicing results. Contents of data stored are different depending on splicing mode.

Display Splice Record

Splicing results stored in the memory can be displayed.

Select [Data Storage] Menu, then select [Display Splice Record] to check the records.

Clearing Splicing Results in Memory

Splicing results can be cleared by part or whole.

(1) Select [Clear Splice Memory] and Input specific number (begin-number and end-number) of splicing results to be cleared.

(2) Select [Clear Splice Record] to execute clearing.

Cancel Data Storage

If you don’t want to store the records, select <ON> in the [Cancel data storage] Menu.

System Setting

This menu is used to change system parameters and set user authority.

PAGE 29

User’s Manual

INNO Instrument, Inc.

Change Monitor Position

The splicer is shipped from the factory with default setting for "Monitor Front" operation. This can be changed to "Monitor Rear" operation. When [Monitor

Position] is changed, the direction of the arrow keys is reversed.

Operating procedure:

① Select [Monitor Position] in [System Setting] menu.

② Select a monitor position as you like (front/rear).

PAGE 30

Note: Press "↑ ↓" to swift the monitor position quickly.

User’s Manual

INNO Instrument, Inc.

Power Save

This function is important for battery conservation. If the power saving function is not set during battery pack use, the number of splicer cycles will be reduced.

(1) Insert a power unit and turn splicer power on.

(2) Select [Power Save Option] in the [System Setting]. [Power Save Option] is displayed for the type of power supply used.

(3) Change value of [Monitor Shut Down] AND [Splice Shut Down].

System Information

Select [System Information], the following information is displayed.

PAGE 31

User’s Manual

INNO Instrument, Inc.

Appendix I

Splice loss increase: Reason and solution.

PAGE 32

User’s Manual

INNO Instrument, Inc.

Appendix II

During the splice operating process, if the error messages is shown on the screen.

Follow the solution precisely as shown in the list below. If it is not possible to eliminate the problem, the splicer may require service by a qualified service center.

Please contact with sale agent.

PAGE 33

User’s Manual

INNO Instrument, Inc.

PAGE 34

User’s Manual

INNO Instrument, Inc.

Appendix III

Questions and Troubleshooting

1. Power does not turn off when pressing NO/OFF button.

★ Press and hold the key until the LED color changes from green to red.

2. Few splices can be made with a fully charged battery pack

★ If the power saving function is not enabled, battery power degrades quicker.

★ Always enable it to conserve power usage.

★ If degradation appears (memory effect), or if the battery pack is stored for an extended period of time, completely discharge it. After discharge completion, recharge the battery pack.

★ The battery pack has reached the end of its service life. Install a new battery pack.

★ The battery pack uses chemical reaction. The capacity decreases at low temperature,especially at lower than 0 degree C.

3. Error message appears on monitor

★ Please refer to appendix II.

4.Inconsistent splice loss / High splice loss

★ Clean the V-grooves, fiber clamps, wind protector mirrors, and objective lenses.

★ Replace the electrodes.

★ Please refer to Appendix I.

★ The splice loss varies according to the cleave angle, arc conditions and fiber cleanliness.

5. Monitor suddenly turned off

★ The monitor will turn off after an extended period of splicer inactivity, if the power saving function is enabled. Press any key to return to the normal state.

6. Splicer power suddenly turned off without “Low Battery” message

★ The monitor will turn off after an extended period of splicer inactivity, if the power saving function is enabled. Press any key to return to the normal state.

7. Identify fibers error in AUTO mode

★ AUTO mode is applicable for SM, MM, NZ fiber. Errors may occurs while splicing special fibers.

8. Mismatch between Estimated splice loss and Actual splice loss

The estimated loss is a calculated loss, so it can be used for reference only.

The optical components of the splicer may need to be cleaned.

9. Fiber protection sleeve does not shrink completely.

Extend the heating time.

10. Method to cancel heating process.

Press Heat key to stop during heating process. The LED light will go off after pressing.

PAGE 35

User’s Manual

INNO Instrument, Inc.

11. Fiber protection sleeve adhered to heating plate after shrinking

Use a cotton swab or a similar soft tip object to push and remove the sleeve.

12. Forgot password

Please contact the sale agent.

13. No arc power change after [Arc Calibration]

The displayed arc power in each splice mode does not change.

14. Forgot to load fibers while execute some specified function that fibers are needed.

splicer, and press SET to continue or press RESET.

15. Upgrading failure

When users use the "new" U-disk to upgrade, the splice may not be able to splicer.

If you cannot solve the problems, please contact the sale agent.

16. Other

Please refer to the video in user's CD.

Manufacturer:

INNO INSTRUMENT, INC.

Address: 65-3, Sangdaewondong, Jungwongu, Sungnamsi,

Kyeonggido 462-807, Republic of Korea.

Tel: +82 31 742-8755 www.innoinstrument.com

China Branch:

INNO INSTRUMENT(SHANGHAI) INC.

Address: 6F Building 39, No.333 Qinjiang Road, Xuhui

District, Shanghai, China.

Tel: +86 21 6405-6995 www.innoinstrument.com

INNO IFS-18 Exclusive agent in mainland China:

SHENZHEN EASTSEA PHOTOELECTRIC TECHNOLOGY CO., LTD.

Address: 11B, HongSong Building A, TaiRan 9 Road, Futian

District, Shenzhen, Guangdong Province, China.

Tel: +86 755 8860-8360 www.eastseachina.com

PAGE 36

The End

* Design is subject to change without prior notice.