Mechanical

Temperature Measurement

Bimetal Thermometer

Model TI.50, Stainless Steel Case & Wetted Parts

Datasheet TI.50

Applications

Suitable for fluid medlium which does not corrode 304 stainless steel

Special features

Industrial design

Back connection with external reset

Stainless steel case and wetted parts

Standard version

Sizes

5" (127 mm) Type TI.50

Accuracy

+ 1.0% full scale value (ASME B40.3)

Ranges

-100 o F to 1000 o F (and equivalent Celsius)

Working Range

Steady: full scale value

Short time: 110% of full scale value

Over Range

Temporary over or under range tolerance of 50% of scale up to 500 o F. (260°C). For ranges above 500°F, maximum over range is 800°F; continous. 1000°F intermittent.

Connection

Material: 304 stainless steel

Center back mount (CBM), 1/2" NPT

Stem

Material: 304 stainless steel

Diameter: ¼" (6.35 mm)

Length: 2 ½" to 72" (63.5 mm to 1,828.8 mm)

Measuring Element

Bi-metal helix

Datasheet TI.50 · 6/2005

Thermometer TI.50

Case

Material: 304 stainless steel

Hermetically sealed per ASME B40.3 standard

External reset slotted hex head on back of case

Dial

White aluminum, dished, with black markings

Pointer

Black aluminum

Dampening

Inert gel to minimize pointer oscillation

Standard Scales

Single: Fahrenheit or Celsius

Dual: Fahrenheit (outer) and Celsius (inner)

Window Gasket

Neoprene

Silicone (-100 o F and over 550 o F)

Window

Flat instrument glass

Weight

16 oz. (5" dial)

Add 1 oz for every 2" of stem length

Warranty

7- Year Warranty

Page 1 of 2

Optional Extras

Thermowells

Silicone fill

Dampened Movement

Special scales and dial markings

Acrylic and safety glass windows

Calibration certification traceable to NIST

Min/max pointer

DIN standards

STANDARD RANGES

Fahrenheit

Single Scale

-100/150 F

Dual Scale F & C

F Outer, C Inner

-100/150 F & -70/70 C

-40/120 F

0/140 F

0/200 F

40/120 F & -40/50 C

0/140 F & -20/60 C

0/200 F & -15/90 C

0/250 F

20/240 F

25/125 F

50/300 F

50/400 F

50/550 F

150/750 F

200/1000 F 1

0/250 F & -20/120 C

20/240 F & -5/115 C

25/125 F & -5/50 C

50/300 F & 10/150 C

50/400 F & 10/200 C

50/500 F & 10/260 C

150/750 F & 65/400 C

200/1000 F & 100/540 C 1

2 Not recommended for continous service over 800°F (425°C)

Celsius

Single Scale

-50/50 C

-20/120 C

0/50 C

0/100 C

0/150 C

0/200 C

0/250 C

0/300 C

0/450 C 1

100/550 C 1

Dimensions

Standard versions

WIKA TYPE

50

DIAL SIZE

5" (127 mm)

A

5¼" (133.4 mm)

B

15/16" (23.8 mm)

S (Stem Length)

As Specified

STEM LENGTH

2½" (63.5 mm)

4" (101.6 mm)

6" (152.4 mm)

9" (228.6 mm)

12" (304.8 mm)

15" (381.0 mm)

18" (457.2 mm)

24" (609.6 mm)

Note: Thermowells for temperature instruments are recommended for all process systems where pressure, velocity, or viscous, abrasive and corrosive materials are present individually or in combination. A properly selected thermowell protects the temperature instrument from possible damage resulting from these process variables. Furthermore, a thermowell permits removal of the temperature instrument for replacement, repair or testing without effecting the process media or the system.

Ordering information

State computer part number (if available) /type number/size/range/connection size and locations/options required. WIKA reserves the right to make changes without prior notice.

Page 2 of 2 Datasheet TI.50· 6/2005

WIKA Instrument Corporation

1000 Wiegand Boulevard

Lawrenceville, GA 30043

1-888-WIKA-USA /770-513-8200 (in GA)

Fax 770-338-5118 [email protected] www.wika.com