Hinkley Lighting 5895OB Bolla 100W 5-Light Bath Vanity Fixture Installation manual

Add to My manuals
2 Pages

advertisement

Hinkley Lighting 5895OB Bolla 100W 5-Light Bath Vanity Fixture Installation manual | Manualzz

assembly instructions

Family: Avon Item No. 5895

Drawing 1 - Strap Detail

F A B

2

1

G C D

Drawing 2 - Fixture Assembly

4

3

5

start here

1. Find a clear area in which you can work.

2. Unpack fixture and glass from carton.

3. Carefully review instructions prior to assembly.

*** The construction of this fixture will be accomplished by first mounting the mounting strap to the junction box, making all necessary electrical connections, mounting the fixture to the wall and then installing the fixture glass.

1. Remove ball knobs (C) from fixture - see Drawing 1 .

2. Reomve retainer plate (A) from backplate (D) .

3. Attach retainer plate (A) to junction box using 2 screws (B) .

4. Additional screws can be installed at points (E) .

SAFETY WARNING: READ WIRING AND GROUNDING INSTRUCTIONS (I.S. 18)

AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING

INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULT A QUALIFIED

ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS.

Make electrical connections from supply wire to fixture lead wires. Refer to instruction sheet (I.S. 18) and follow all instructions to make all necessary wiring connections.

Then refer back to this sheet to complete installation of this fixture.

1. Slip holes (G) in backplate (D) over screws (F) on retainer plate (A) .

2. Thread ball knobs (C) onto end of screws (F) and tighten to secure backplate to wall.

1. To install glass, remove the spacer (3) and socket ring (4) from the socket (1) - see

Drawing 2 .

2. Place glass (2) over the socket (1) .

3. Slip spacer (3) and thread socket ring (4) back on to socket (1) and hand tighten.

Note: Over tightening could cause damage to glass.

4. Repeat steps 1-3 for remaining glass.

5. Fixture can now be lamped accordingly.

10.20.10

H I N K L E Y L I G H T I N G 33000 Pin Oak Parkway Avon Lake, OH 44012 800.446.5539 / 440.653.5500 hinkleylighting.com

I.S. 18

wiring grounding instructions

Drawing 1 - Flush Mount

supply wire

C E

1

B D fixture leads twist-on connectors

2

Drawing 2 - Chain Hung

supply wire

A C

EE twist-on connectors

1

B D fixture leads

EE 2

Drawing 3 - Post-Mount

supply wire

A C

E twist-on connectors

E

B D fixture leads

SAFETY WARNING: READ WIRING AND GROUNDING INSTRUCTIONS (I.S. 18)

AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING

INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULT A QUALIFIED

ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS.

wiring instructions

Indoor Fixtures

1. Connect positive supply wire (A) (typically black or the smooth, unmarked side of the two-conductor cord) to positive fixture lead (B) with appropriately sized twist on connector - see Drawings 1 or 2 .

2. Connect negative supply wire (C) (typically white or the ribbed, marked side of the two-conductor cord) to negative fixture lead (D) .

3. Please refer to the grounding instructions below to complete all electrical connections.

Outdoor Fixtures

1. Connect positive supply wire (A) (typically black or the smooth unmarked side of the two-conductor cord) to positive fixture lead (B) with appropriately sized twist on connector - see Drawings 2 or 3 .

2. Connect negative supply wire (C) (typically white or the ribbed, marked side of the two-conductor cord) to negative fixture lead (D) .

3. Cover open end of connectors with silicone sealant to form a watertight seal.

• If installing a wall mount fixture, use caulk to seal gaps between the fixture mounting plate (backplate) and the wall. This will help prevent water from entering the outlet box. If the wall surface is lap siding, use caulk and a fixture mounting platform specially.

4. Please refer to the grounding instructions below to complete all electrical connections.

grounding instructions

Flush Mount Fixtures

For positive grounding in a 3-wire electrical system, fasten the fixture ground wire (E) (typically copper or green plastic coated) to the fixture mounting strap (1) with the ground screw (2) - see Drawing 1 .

Note: On straps for screw supported fixtures, first install the two mounting screws in strap.

Any remaining tapped hole may be used for the ground screw .

Chain Hung Fixtures

Loop fixture ground wire (E) (typically copper or green plastic coated) under the head of the ground screw (2) on fixture mounting strap (1) and connect to the loose end of the fixture ground wire directly to the ground wire of the building system with appropriately sized twist-on connectors - see Drawing 2 .

Post-Mount Fixtures

Connect fixture ground wire (E) (typically copper or green plastic coated) to power supply ground with appropriately sized twist-on connector inside post. Cover open end of connector with silicone sealant to form a watertight seal - see Drawing 3 .

H I N K L E Y L I G H T I N G 33000 Pin Oak Parkway Avon Lake, OH 44012 800.446.5539 / 440.653.5500 hinkleylighting.com