IC18 SPREADER

JOB COMPUTER

U S E R M A N U A L

Software version 1.10

European

COPYRIGHTS

© 2017 TeeJet Technologies. All rights reserved. No part of this document or the computer programmes described in it may be reproduced, copied, photocopied, translated, or reduced in any form or by any means, electronic or machine readable, recording or otherwise, without prior written consent from TeeJet Technologies.

TRADEMARKS

Unless otherwise noted, all other brand or product names are trademarks or registered trademarks of their respective companies or organisations.

LIMITATION OF LIABILITY

TEEJET TECHNOLOGIES PROVIDES THIS MATERIAL “AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED OR IMPLIED.

NO COPYRIGHT LIABILITY OR PATENT IS ASSUMED. IN NO EVENT SHALL TEEJET TECHNOLOGIES BE LIABLE FOR ANY LOSS OF

BUSINESS, LOSS OF PROFIT, LOSS OF USE OR DATA, INTERRUPTION OF BUSINESS, OR FOR INDIRECT, SPECIAL, INCIDENTAL,

OR CONSEQUENTIAL DAMAGES OF ANY KIND, EVEN IF TEEJET TECHNOLOGIES HAS BEEN ADVISED OF SUCH DAMAGES ARISING

FROM TEEJET TECHNOLOGIES SOFTWARE.

To ensure optimal use of the equipment, please read this manual thoroughly. Please contact TeeJet Technologies Customer Support or an authorized TeeJet Technologies dealer if additional support is required.

RESPONSIBILITY FOR USE OF THIS PRODUCT

Regarding responsibility for use of this product, we refer to our sales and delivery terms which states:

Product Usage

Any use of the product is at the sole risk of the buyer. The buyer is therefore not entitled to any form for compensation caused by, for example, any of the following:

►Disturbance to/from any electronic services or products that do not conform to the standards for CE marketing;

►Missing or poor signal coverage or a succession hereof from external transmitters/receivers used by the buyer; Functional faults which apply to or from a PC-program or PC equipment not delivered by the seller;

►Faults that may arise from the buyers’ negligence to react to warnings and fault messages from the product or that can be traced to negligence and/or absent constant control of the work carried out in comparison to the planned job.

When implementing any new equipment the buyer must take great care and pay attention. Any doubts as to the correct operation/use should result in contacting the seller’s service department.

ISOBUS Job Computer: IC18 Spreader

Table of contents

CHAPTER 1– INTRODUCTION

CONFIGURATIONS 1

START UP 2

PROGRAMME MODE

HOME SCREEN

OPERATION MODE SCREEN

MAIN SETUP SCREEN

SETTINGS OPTIONS NAVIGATION

3

4

2

3

5

CHAPTER 2 – OPERATION MODE

PROGRAM MODE 6

OPERATION MODE OVERVIEW 6

APPLICATION RATE OPTIONS 8

Target rate ............................................................................................................................................................................................... 8

Target rate percentage increase/decrease ......................................................................................................................8

Roller increase/decrease indicators .................................................................................................................................8

START/STOP APPLICATION 9

INFORMATION KEY 9

CHAPTER 3 – MAIN SETUP

COUNTERS 11

Trip counters ..........................................................................................................................................................................................11

Campaign counters.............................................................................................................................................................................12

Total counters .......................................................................................................................................................................................12

Export counters ....................................................................................................................................................................................12

JOB PARAMETERS 13

MACHINE 14

Filling ........................................................................................................................................................................................................15

Operation ...............................................................................................................................................................................................15

Implement Parameters ......................................................................................................................................................................15

Calibrations ............................................................................................................................................................................................16

Application rate ..............................................................................................................................................................16

Volume per impulse .......................................................................................................................................................17

Amount per impulse ......................................................................................................................................................18

Hydraulic system ...........................................................................................................................................................18

Implement speed sensor ...............................................................................................................................................19

Weighing system ...........................................................................................................................................................19

Alarm configurations ..........................................................................................................................................................................20

OEM ..........................................................................................................................................................................................................20

USER INTERFACE 21

COMMUNICATION 22

98-05173-EN R1 i

10

1

6

ISOBUS Job Computer: IC18 Spreader

HELP 22

Diagnostic ..............................................................................................................................................................................................23

Test input .......................................................................................................................................................................23

Test output .....................................................................................................................................................................23

UT data ..........................................................................................................................................................................23

TECU .............................................................................................................................................................................24

About .......................................................................................................................................................................................................24

Factory settings ....................................................................................................................................................................................24

SETTINGS MENU OPTIONS 25

CHAPTER 4 – TRANSPORT MODE

CHAPTER 5 – HOME SCREEN SHORTCUTS

Fast empty key shortcut .................................................................................................................................................28

Filling shortcut key .........................................................................................................................................................28

Application rate shortcut key ..........................................................................................................................................28

CHAPTER 6 – OEM OPTIONS

Sensors ....................................................................................................................................................................................................30

Actuators ................................................................................................................................................................................................30

User Interface ........................................................................................................................................................................................31

Regulator Configuration ...................................................................................................................................................................31

Regulator Test ................................................................................................................................................................31

Valve Configuration (Belt Valve Type: Servo) ................................................................................................................32

PID Parameters .............................................................................................................................................................32

PWM Signal (Belt Valve Type: PWM) ............................................................................................................................32

Load Valve Parameters (Belt Valve Type: PWM) ...........................................................................................................33

Calibration RPM ....................................................................................................................................................................................33

Program Modes ....................................................................................................................................................................................34

Reference Gate Height (Program Style: North America) .......................................................................................................34

Clear Total Counters ............................................................................................................................................................................35

TC-Implement Settings ......................................................................................................................................................................35

APPENDIX A - FACTORY SETTINGS & RANGES

APPENDIX B - UNIT SPECIFICATIONS

27

28

29

37

39

ii www.teejet.com

ISOBUS Job Computer: IC18 Spreader

CHAPTER 1– INTRODUCTION

Congratulations on the purchase of your new IC18 Spreader ECU built on the ISOBUS architecture. When used within the guidelines of the this manual, the IC18 Spreader controller will be a reliable application tool.

This manual covers the European functions of the IC18 ECU. For North American functions, see manual number 98-05173.

Use with your existing universal terminal (UT) for dry product application Figure 1-1: IC18 job computer

Product Benefits:

• Works seamlessly and displays on any ISOBUS UT.

• Easy navigation menu and data rich display.

• Add additional ISOBUS ECUs as your needs change.

• Provides basic rate control or variable rate if the connecting UT has variable rate task control capabilities.

• Standardized plugs, cables and software simplify installation and connectivity and result in true “plug and play” technology.

IC18 Spreader ECU resides on the implement, reducing hardware in the cab.

CONFIGURATIONS

The following diagram is reflective of typical a IC18 job computer configuration. Due to the variety of possible configurations, this should be used for reference purposes only.

Figure 1-2: IC18 spreader to universal terminal (UT)

Aeros console

Antenna

RXA-30

90-02720

199-291 - Harness, Aeros UT, TJT

Junction box only

Power cable, Battery to COBO plug

96ET14 - 4m cable

96ET14_6 - 6m cable

904-252 - Tractor junction box

COBO, IBBC

Harness, IC18 to

ISOBUS Hitch

Track/chain RPM sensor

45-10143 - IC18-Valve Harness

IC18 Spreader

Motor or proportional valve

98-05173-EN R1

1

ISOBUS Job Computer: IC18 Spreader

START UP

Power is continuously supplied to the job computer. The Universal Terminal (UT) will give access to the job computer options and operation.

• A firm touch is required when selecting a screen icon.

• Settings are NOT automatically saved when selected. The ACCEPT KEY must be selected to save the setting. Select the ESCAPE

KEY to escape without saving settings and return to the previous menu.

• The console needs to be cycled “off” and back on when changing or attaching equipment to the system.

NOTE: The menu structure on your display might vary from the one displayed in this user manual depending on the universal terminal (UT) being used.

PROGRAMME MODE

The IC18 job computer is programmeed to calculate calibrations based on North America or European methods.

◄European – Gate height is NOT calculated into the product application and calibrations will be based on Volume per impulse.

◄North America – Gate height is calculated into the product application and calibrations will be based on Impulses per volume.

This setting has been established before leaving the factory, but it can be changed after purchase with assistance from

TeeJet Technologies Customer Service or your local dealer through the OEM setup menu options.

Figure 1-3: European

Figure 1-4: North America

This manual discusses specifically the functions and options in European mode. See the specific IC18 Spreader: North America user manual for functions and options in North America mode.

2 www.teejet.com

ISOBUS Job Computer: IC18 Spreader

HOME SCREEN

The Home screen gives access to the IC18’s available functions. Power is continuously supplied to the job computer. The universal terminal (UT) will give access to the job computer options and operation.

NOTE: Information on the ECU will vary depending on the parameters set by the user and the OEM.

Figure 1-5: Home screen

Operation Mode

Available

ECUs

Filling Shortcut

Main Setup

Transport Mode

Fast Empty Shortcut

Application Rate Shortcut

Quick View

Table 1-1: Home screen functions and desctiptions

Function

Available ECUs (image varies depending on systems available)

Operation mode

Filling shortcut

Description

Systems currently available on your UT are displayed in the left hand coloumn of every page.

To navigate between systems simply press the icon to open the desired system.

Accesses the Operation screen of the IC18 Spreader including application control, rate control and trip/count/application information

Accesses the Filling screen to establish the amount of material remaining in the bed

Main setup mode

Transport mode

Fast empty shortcut

Application rate shortcut

Quick view

Menu to input various spreader settings.

Locks all spreading and hydraulic functions to prevent accidents.

Allows the user to empty the bed of its contents without having the spinners on

Accesses calibration of the active flow factor

Information displayed is based on the current active trip

OPERATION MODE SCREEN

Information on the Operation screen will vary depending on the parameters set by the user and the OEM.

Figure 1-6: Operation screen

Active trip count number Applied amount

Target rate indicator

Applied area

Alert warning

Speed/application information

Remaining bed content

Edge spreading indicator

Application on/off indication

Target rate percentage increase/decrease

Home

Boost/step % reset

Information

Working width increase

Start/stop

Working width decrease

Boost/step % increase

Working width reset

Boost/step % decrease

Roller RPM Spinner RPM Roller increase/decrease indicators

Application rate

98-05173-EN R1

3

ISOBUS Job Computer: IC18 Spreader

MAIN SETUP SCREEN

The main setup menu contains six (6) options. Each of these options either directly access settings or additional menus.

Figure 1-7: Main setup screen

Home

Back one screen

Forward one screen

Up one selection

Down one selection

The table below outlines the additional menus and directs you to the setup pages for further information.

|

Counters

|

MAIN SETUP MODE MENU STRUCTURE

| | |

Job Parameters Machine User Interface Communications

X Trip X *Filling

X Campaign

X Total

X Export

X Operation

T Implement parameters

T Calibrations

X *Application rate

X *Impulses per volume

X *Volume per impulse

X *Amount per impulse

X *Hydraulic system

X Implement speed sensor

X *Weighing system

X Alarm configurations

X OEM

X Sensors

X Actuators

X User interface

X Regulator configuration

X Calibration RPM

X Program modes

X Delete total counters

X TC - implement settings

|

Help

X Diagnostic

X About

X Factory settings

The OEM setup menu is password protected and the settings in this menu are directly related to the fitted OEM equipment.

*Menu settings directly related to OEM equipment.

4 www.teejet.com

ISOBUS Job Computer: IC18 Spreader

SETTINGS OPTIONS NAVIGATION

Figure 1-8: Enter selection screens

Selection

Slide bar with decrease one selection and increase one selection arrows

Accept

Escape

Number pad

Close number pad

Range maximum

Range minimum

Zoom in

Zoom out

Open number pad

Available selections

Up one selection

Accept

Escape

Down one selection

Table 1-2: Sections and icon descriptions

Section or icon Description

Selection

Slide bar

Displays the current or new selection

Selects the setting by pressing and releasing on the slide bar or pressing and dragging the slider to a designated value. Range for a specific setting is displayed on the slide bar.

Slider Slide to the left to decrease or right to increase the selection

Increases the setting Increase one selection arrow

Decrease one selection arrow

Number pad

Decreases the setting

Use the numbers to set the selection value

Section or icon

Open number pad

Close number pad

Accept

Escape

Up one selection arrow

Down one selection arrow

Zoom in

Zoom out

Description

Maximizes the number pad

Minimizes the number pad

Accepts the new selection

Escapes without saving changes

Highlights the selection above

Highlights the selection below

Narrows slide bar range.

Grey = maximum zoom level.

Expands slide bar range.

Grey = minimum zoom level.

98-05173-EN R1

5

ISOBUS Job Computer: IC18 Spreader

CHAPTER 2 – OPERATION MODE

The Operations screen accesses the working aspects of the IC18 including boom section control, rate control and trip/count/application information.

NOTE: Settings are automatically saved when selected.

NOTE: The menu structure on your display might vary from the one displayed in this User Manual depending on the UT being used.

PROGRAM MODE

The IC18 job computer is programed to calculate calibrations based on European or North American methods.

◄European – Gate Height is NOT calculated into the product application and calibrations will be based on volume per pulse.

◄North America – Gate Height is calculated into the product application and calibrations will be based on pulses per volume.

This setting has been established before leaving the factory, but it can be changed after purchase with assistance from TeeJet

Technologies Customer Service or your local dealer through the OEM setup menu options.

OPERATION MODE OVERVIEW

Information on the Operation screen will vary depending on the parameters set by the user and the OEM.

Figure 2-1: Operation mode screen overview

Target rate indicator

Active trip count number Applied amount Applied area

Target rate percentage increase/decrease

Alert warning

Speed/application information

Remaining bed content

Edge spreading indicator

Application on/off indication

Home

Boost/step % reset

Information

Working width increase

Start/stop

Working width decrease

Boost/step % increase

Working width reset

Boost/step % decrease

Roller RPM Spinner RPM Roller increase/decrease indicators

Application rate

Table 2-1: Key/button descriptions

Key/button

Home

Information

Start/stop

Description

Press to return to the Home screen

Press to toggle between display modes

Press to start or stop spreader

Boost/step percentage increase/decrease

Press to establish the required boost percentage step, i.e. the step size, at which the application rate is to increase/decrease with the boost function

NOTE: Application rate step percentage can be defined under

Main -> Machine -> Operation -> Application rate step.

Boost/step percentage reset Press to return to target rate and reset the boost/step percentage to zero

Working width increase/ decrease

Working width reset

Press to increase or decrease the required working width

NOTE: Working width can be defined under Main -> Machine -> Implement parameters -> Working width

Press to cancel any changes made to the working width

6 www.teejet.com

ISOBUS Job Computer: IC18 Spreader

Table 2-2: Section and icon descriptions

Section or icon

Active trip information

Description

This information bar displays the Active trip count number,

Applied amount and Applied area

Active trip

Applied amount

Applied area

Speed/application information

Remaining bed contents

Application on/off indication

Application rate

Trip mode – connected to an ISOBUS CAN with only a UT device found, the current active trip or job number will be displayed

Task controller (TC) mode – connected on an ISOBUS CAN with a TC device found, then TC will be displayed

Displays amount applied for the selected Active trip count number

Displays applied area for the selected Active trip count number

Displays vehicle speed, amount applied per minute or RPM.

The Information key toggles between display modes.

Displays the remaining bed content

NOTE: If no bed sensor is fitted or the contents are not entered in the Filling menu prior to spreading, Bed contents will display “0”.

Displays if application is active or inactive

Displays the actual application rate per hectare/acre

.

NOTE: When the Master is “On” the actual application rate per hectare/ acre will be displayed. When the Master is “Off” the target rate is displayed and the TARGET RATE ICON appears.

Roller increase/decrease indicators

Target rate percentage increase/decrease

Indicates if the rollers need to increase or decrease to meet the target application rate at the current speed.

Displays boost percentage step, i.e. the step size, at which the application rate is to increase/decrease with the boost function.

Alarm warning

Roller RPM

Spinner RPM

Work width metre

Edge spreading sensor

Displayed if an alarm condition is active

Displays the RPM of the belt roller

Displays the RPM of the spinner

Displays the application distribution width

Displays if border spreading is activated

98-05173-EN R1

7

ISOBUS Job Computer: IC18 Spreader

Home screen shortcut keys

From the Home screen, shortcuts to Filling, Fast empty and Application rate settings are available.

• To view the Home screen, select HOME KEY in the top right corner of any screen.

Figure 2-2: Home screen

Filling shortcut

Fast empty shortcut

Application rate shortcut

APPLICATION RATE OPTIONS

Target rate

The Target application rates defines one (1) target rate of product being applied per hectare/acre and is indicated by the target icon .

Target application rate is established in the Job parameters under

Application rate.

Figure 2-3: Application target rate

Figure 2-4: Application target rate

Target rate percentage increase/decrease

Target rate percentage increase/decrease keys adjust the application target rate per the established percentage set in the

Machine Operation setup screen under Application rate step.

• To adjust the application rate, press the BOOST/STEP %

INCREASE/DECREASE KEYS .

• To cancel the application rate percentage increase/decrease, press the BOOST/STEP % RESET KEY .

Roller increase/decrease indicators

Indicates if the rollers need to increase or decrease to meet the target application rate at the current speed.

Figure 2-5: Roller increase/decrease indicators

8 www.teejet.com

ISOBUS Job Computer: IC18 Spreader

START/STOP APPLICATION

Starting/stopping application is controlled using the Start/stop keys.

• To start or stop the application, press the START/STOP KEYS .

Figure 2-6: Spreading stopped Figure 2-7: Spreading started

Press to start spreading

Press to stop spreading

INFORMATION KEY

The INFORMATION KEY toggles the Speed/application Information section on the Operation screen between the display modes.

• Vehicle speed

• Amount applied per minute

• Target roller RPM

Figure 2-8: Information key

Vehicle speed

Amount applied per minute

Target roller RPM

98-05173-EN R1

9

ISOBUS Job Computer: IC18 Spreader

CHAPTER 3 – MAIN SETUP

Main setup mode configures the Counters, Job parameters, Machine, User interface, Communication and Help options.

NOTE: The menu structure on your display might vary from the one displayed in this user manual depending on the UT being used.

|

Counters

|

MAIN SETUP MODE MENU STRUCTURE

| | |

Job parameters Machine User interface Communications

|

Help

X Trip X *Filling X Diagnostic

X Campaign

X Total

X Operation

T Implement parameters

X About

X Factory settings

X Export T Calibrations

X *Application rate

X *Impulses per volume

X *Volume per impulse

X *Amount per impulse

X *Hydraulic system

X Implement speed sensor

X *Weighing system

X Alarm configurations

X OEM

X Sensors

X Actuators

X User interface

X Regulator configuration

X Calibration RPM

X Program modes

X Delete total counters

X TC - implement settings

The OEM setup menu is password protected and the settings in this menu are directly related to the fitted OEM equipment.

*Menu settings directly related to OEM equipment.

1. Select MAIN SETUP SCREEN KEY from the Home screen.

2. Select from:

►Counters – used to provide an overview of various system counters.

◄ Trip – used to display information regarding area, distance, time and amount applied.

◄ Campaign – used to display information regarding area, amount applied and time for all trips.

◄ Total – used to display information regarding area, amount applied and time for all activity.

◄ Export counters – allows counter information to be exported in HTML or CSV format.

►Job parameters – used to configure application settings including Trip counter, Application rate, Tonnage, Bed size, Density and Flow factor.

►Machine – used to configure machine settings:

◄ Filling – establishes the amount of material remaining in the bed.

◄ Operation – establishes Speed source and Simulated speed.

◄ Implement parameters – establishes the Working width, Fast empty bed RPM and Master switch location.

◄ Calibrations – establishes either manual or automatic settings of the sensors.

◄ Alarm configurations – establishes alarms “on” or “off” as well as sets their trigger level.

◄ OEM – the OEM setup menu is password protected and the settings in this menu are directly related to the fitted OEM equipment. Refer to the OEM setup manual for information regarding OEM settings.

►User interface – used to allow the operator to select the system UT if more than one UT is available on the ISOBUS CAN.

►Communication – used to establish the IC18's ability to communicate with an external computer.

►Help – allows the operator to perform diagnostics, access the About screen and reset the system to factory settings:

10 www.teejet.com

ISOBUS Job Computer: IC18 Spreader

◄ Diagnostic – used to troubleshoot input/output of the controller (sensor or actuator).

◄ About – used to provide information on the console such as software version, build number, etc.

◄ Factory settings – used to reset the system to factory default settings.

NOTE: The menu structure on your display might vary from the one displayed in this user guide depending on the UT being used. This user guide will display all possible options.

Figure 3-1: Main setup screen

Home

Back one screen

Forward one screen

Up one option

Down one option

COUNTERS

The Counters menu provides an overview of various system counters including Trip counters, Campaign counters and Total counters. From this screen one can also Export counters.

|

Counters

|

MAIN SETUP MODE MENU STRUCTURE

| | |

Job parameters Machine User interface Communications

|

Help

X Trip

X Campaign

X Total

X Export

1. From the Main setup screen , select COUNTERS.

2. Select from:

►Trip – used to display information regarding area, distance, time and amount applied.

►Campaign – used to display information regarding area, amount applied and time for all trips.

►Total – used to display information regarding area, amount applied and time for all activity.

►Export counters – allows counter information to be exported in HTML or CSV format.

Figure 3-2: Counters

Trip counters

Trip counters displays information regarding area, distance, time and amount applied. The trip that is active is displayed/active on the

Operations screen.

Figure 3-3: Trip counters

Active trip counter

One of up to ten (10) active trip counters can be selected to view the desired trip information. The trip that is “active” is displayed/ active on the Operation screen.

• To clear the Trip counters, select RECYCLE BIN KEY . A confirmation screen will be displayed.

Area counter

Displays applied area for the selected active trip.

98-05173-EN R1

11

ISOBUS Job Computer: IC18 Spreader

Distance counter

Displays distance travelled for the selected active trip.

Time counter

Displays time travelled for the selected active trip.

Total counters

Total counters displays information regarding area, amount applied and time for all activity. Total counters can only be cleared in the

OEM menu.

Figure 3-5: Total counters

Amount

Displays amount of material applied during the selected active trip.

Campaign counters

Campaign counters display information regarding area, amount applied and time for all trips.

• To clear the Campaign counters, select RECYCLE BIN

KEY . A confirmation screen will be displayed.

Figure 3-4: Campaign counters

Area counter

Displays total applied area for all trips.

Amount counter

Displays total amount of material applied during all trips.

Time counter

Displays total time travellled for all trips.

Password to clear

If a password was established in the OEM menu, it will be required to clear the Campaign counter.

Area counter

Displays total applied area for all trips.

Amount counter

Displays total amount of material applied during all trips.

Time counter

Displays total time travellled for all trips.

Export counters

Export counters allows counter information to be exported in HTML or CSV format. HTML files can be viewed from an internet browser.

CSV files can be viewed as Excel sheets.

• To export a HTML file, select HTML KEY . A confirmation screen will be displayed.

• To export a CSV file, select CSV KEY . A confirmation screen will be displayed.

• Follow the instructions displayed.

For data transfer, an optional cable is required. Contact your local dealer for additional information.

Figure 3-6: Export counters

12 www.teejet.com

ISOBUS Job Computer: IC18 Spreader

JOB PARAMETERS

Job parameters configures application settings. Options include Active trip counter, Application rate, Tonnage, Bed size, Density and Flow factor.

|

Counters

|

MAIN SETUP MODE MENU STRUCTURE

| | |

Job parameters Machine User interface Communications

|

Help

1. From the Main setup screen , select JOB PARAMETERS.

Figure 3-7: Job parameters

Active trip counter

Active trip counter selects one of up to ten (10) active trip counters to view the desired trip information. The trip that is “active” is displayed/active on the Operation screen.

NOTE: The selected trip counter will have all data modified (added to) when additional operations are activated. If current trip counter is not cleared, the new data will be added to the existing data.

Application rate

Application rate defines a target rate of product being applied per hectare/acre. This setting will set the same for all active trips.

Tonnage

Tonnage converts pounds/kilograms to tons. It is used when the application rate exceeds the number of digits allowed on the screen display.

NOTE: For specific calibration options to appear, a specific sensor needs to be installed or a programme mode needs to be selected. Sensor availability is activated on the Sensor presence screen in the OEM section. Programme mode is established in the OEM section.

Bed size

Bed size defines the maximum amount that can fit in the holding container.

Density

Density defines the weight of the material being applied.

Flow factor

The fertiliser’s ability to flow is affected by a number of factors

(shape, grain, weight, moisture). These factors may vary with each batch and it may change due to weather (humidity, etc.). In order to accommodate for this, the IC18 uses a flow factor to compensate for the nature of the applied fertiliser .

98-05173-EN R1

13

ISOBUS Job Computer: IC18 Spreader

MACHINE

Machine configures machine settings. Options include Filling, Operation, Implement Parameters, Calibrations, Alarm Configurations and

OEM.

|

Counters

|

MAIN SETUP MODE MENU STRUCTURE

| | |

Job parameters Machine User interface Communications

|

Help

X *Filling

X Operation

T Implement parameters

T Calibrations

X *Application rate

X *Impulses per volume

X *Volume per impulse

X *Amount per impulse

X *Hydraulic system

X Implement speed sensor

X *Weighing system

X Alarm configurations

X OEM

X Sensors

X Actuators

X User interface

X Regulator configuration

X Calibration RPM

X Program modes

X Delete total counters

X TC - implement settings

The OEM setup menu is password protected and the settings in this menu are directly related to the fitted OEM equipment.

*Menu settings directly related to OEM equipment.

1. From the Main setup screen , select MACHINE.

2. Select from:

►Filling – establishes the amount of material remaining in the bed.

►Operation – establishes Speed source, Application rate step and Simulated speed.

►Implement parameters – establishes the Working width, Fast empty bed RPM and Master switch location.

►Calibrations – establishes either manual or automatic settings of the sensors.

NOTE: Options may vary depending on OEM settings.

►Alarm configurations – establishes alarms “on” or “off” as well as sets their trigger level.

►OEM – The OEM setup menu is password protected and the settings in this menu are directly related to the fitted

OEM equipment. Refer to the OEM chapter for information regarding OEM settings.

Figure 3-8: Machine

14 www.teejet.com

ISOBUS Job Computer: IC18 Spreader

Filling

Filling establishes the amount of material remaining in the bed.

NOTE: The size of the bed is established in the OEM menu. This is the number that will repopulate when the FULL BED KEY

is pressed.

Figure 3-9: Filling

Application rate step

Application rate step is the percent of increase/decrease “boost” of the active application rate at which the product is being applied.

Figure 3-11: Step percentage increase/decrease

Filling - NOT AVAILBLE

Filling is not available when a weight system is activated.

Amount remaining

Amount remaining displays the calculated material left in the bed.

The amount can be manually adjusted.

Full bed

Full bed returns the amount remaining value to the maximum amount of material in the bed.

• To reset the Amount remaining value, press the

FULL BED KEY .

Operation

Operation establishes Application rate step, Speed source and

Simulated speed.

Figure 3-10: Operation

Speed source

Speed source selects whether to base the machine’s speed on input from the CAN, the Implement or a Simulated source. Selecting

“Implement” will allow for the configuration of impulses per 100 metres. Selecting “Simulated” will allow for simulated speed to be entered using the “Edit value” option. Selecting “CAN” allows for speed being supplied by the ISOBUS CAN (usually from the TECU) to be used.

NOTE: If “Implement” is selected, refer to the Calibrations section for further instructions.

Simulated speed

Simulated speed establishes a speed to be used when using the

Simulated speed source.

Implement Parameters

Implement parameters establishes Working width, Fast empty bed

RPM and Master switch location.

Figure 3-12: Implement parameters

Working width

Working width establishes the desired distance between each adjacent pass while spreading.

98-05173-EN R1

15

ISOBUS Job Computer: IC18 Spreader

Fast empty bed RPM

Fast empty bed RPM establishes the revolutions per minute of the roller used to drive the conveyor during the fast empty. The availability of Fast empty bed is established in the OEM menu under Programme modes. When set to “on”, the FAST EMPTY Bed

KEY will be available on the Home screen.

Master switch

Master Switch is used to allow the operator to choose between a remote switch or console. Select "Remote switch" when using a switchbox to operate equipment. Select "Console" to use the

START/STOP KEY on the Operation Screen to operate equipment.

Application rate

An application rate test establishes the corrected flow factor or calibration number using a calibration function. This figure is determined by measuring the bed at a predetermined and pre measured amount and then again after a sufficant amount has been spread. Based on the differences between the measured and known amounts, a factor is determined to accurately calculate future application rates.

NOTE: Options will vary depending on options set in OEM->

Program Modes-> Flow Correction Type.

Figure 3-14: Application rate

Calibrations

Calibrations establishes either manual or automatic settings of the sensors. Different options will be available depending on the OEM->

Programme modes settings.

Calibration options may include the following:

◄Application rate – establishes a corrected flow factor or calibration number using a calibration function.

◄Volume per impulse – establishes the amount of cubic centimetres per one (1) impulse.

◄Amount per impulse – establishes amount of application per one (1) impulse.

◄Hydraulic system – used to calculate the maximum RPM at the machine’s full throttle rate.

◄Implement speed sensor – establishes the wheel pulses over a specified distance.

◄Weighing system – used to determine the amount of product in the bed.

NOTE: For specific calibration options to appear, a specific sensor needs to be installed. Sensor availability is activated on the

Sensors screen in the OEM section. For additional details, see the OEM chapter of this manual or the Setting menu options table.

Figure 3-13: Calibrations

Expected application rate

Expected application rate is the target rate of application in kilograms per hectare.

Actual application rate

Actual application rate is the actual rate of application that is calculated once the test has been completed.

Active flow factor

Active flow factor is the current flow factor.

Corrected flow factor calibration

Corrected flow factor calibration is the actual flow factor that is calculated once the test is completed.

Corrected flow factor procedure:

• Select BEGIN APPLICATION KEY .

• Follow the instructions displayed.

• Press END APPLICATION KEY .

• Follow the instructions displayed.

• Press APPLY CORRECTED FLOW FACTOR KEY

• Follow the instructions displayed.

16 www.teejet.com

ISOBUS Job Computer: IC18 Spreader

NOTE: Material will be dispensed during this procedure. Be sure that remaining bed contents can be determined.

Figure 3-15: Corrected flow factor procedure

Volume per impulse

Volume per impulse establishes the amount of cubic centimetres per one (1) impulse. This value can be established manually or calibrated automatically. Each type of spreader has a variety of variables that factor into the volume per impulse number (roller diameter, sensor type, type of belt or chain, etc.). The volume per impulse number factors these variables into the spreader output .

Figure 3-17: Volume per impulse

Active Calibration Number

Active Calibration Number is the current calibration number.

Corrected Calibration Number

Corrected Calibration Number calibration is the actual calibration number that is calculated once the test is completed.

Corrected Calibration Number Procedure:

• Select BEGIN APPLICATION KEY .

• Follow the instructions displayed.

• Press END APPLICATION KEY .

• Follow the instructions displayed.

• Press APPLY CORRECTED CALIBRATION KEY

• Follow the instructions displayed.

NOTE: Material will be dispensed during this procedure. Be sure that remaining bed contents can be determined.

Figure 3-16: Corrected Calibration Number Procedure

Manual Calibration

Manual calibration establishes the impulses based on a user entered value.

Automatic Calibration

Automatic calibration establishes the volume using the automatic calibration function.

• To calibrate the volume per impulse, select CALIBRATION

KEY .

• Follow the series of instructions displayed.

NOTE: Material will be dispensed during this procedure. Be sure that a collection device is in place so that a proper volume can be determined.

Figure 3-18: Volume per impulse calibration

98-05173-EN R1

17

ISOBUS Job Computer: IC18 Spreader

Amount per impulse

Amount per impulse establishes amount of application per one (1) impulse. This value can be established manually or calibrated automatically. Each type of spreader has a variety of variables that factor into the impulses per amount number (roller diameter, gate height and width, sensor type, type of belt or chain, etc.).

The amount per impulse number factors these variables into the spreader output.

NOTE: This option is available when OEM-> Programme mode is set to Weight based.

Figure 3-19: Amount per impulse

Hydraulic system

The Hydraulic system menu is used to calculate the maximum RPM at the machine’s full throttle rate.

Duty Cycle Offset Calibration RPM value is used while making a

Hydraulic Calibration (Machine-> OEM-> Regulator Configuration->

PWM Signal-> Duty Cycled Offset Calibrations RPM). Once calibration is started, the roller RPM has to reach that minimum value within 10 seconds, else a warning will appear. This is to make sure tractor is providing enough hydraulic oil to make a valid

Hydraulic Calibration.

NOTE: Hydraulic Calibration is used to automatically determine

OEM “Maximum Duty Cycle” and “Duty Cycle Offset” values

(Machine> OEM> Regulator Configuration> PWM Signal).

Figure 3-21: Hydraulic system

Manual calibration

Manual calibration establishes the amount based on a user entered value.

Automatic calibration

Automatic calibration establishes the amount using the automatic calibration function.

• To calibrate amount per impulse, select CALIBRATION

KEY .

• Follow the series of instructions displayed.

NOTE: Material will be dispensed during this procedure. Be sure that a collection device is in place so that a proper weight can be determined.

Figure 3-20: Amount per impulse calibration

Automatic calibration

Calibration establishes the Actual RPM using the automatic calibration function.

• To run the hydraulic calibration, press START KEY .

• Once the Actual RPM has been populated, press the

STOP KEY to complete the calibration.

• Follow the series of instructions displayed.

NOTE: Manual calibration is not available for Hydraulic system calibration.

18 www.teejet.com

ISOBUS Job Computer: IC18 Spreader

Implement speed sensor

The Implement speed sensor establishes the wheel impulses over a specified distance of 100 metres. This value can be established manually or calibrated automatically.

Figure 3-22: Implement speed sensor

Calibrate weighing system

Establishes a calibration figure for calibrating the weighing system sensor. This figure is determined by measuring the bed at empty and at a predetermined and pre measured amount. Based on the differences between the measured and known amounts, a factor is determined to accurately calculate all future weights.

NOTE: If the Weighing system is turned on in the OEM menu,

(OEM-> Sensors-> Sensor configuration) the Weighing system menu item will show as an option on the

Calibrations page.

Figure 3-24: Weighing system calibration

Manual calibration

Manual calibration establishes the impulses based on a user entered value.

Automatic calibration

Automatic calibration establishes the impulses using the automatic calibration function.

• To calibrate impulses per distance, select CALIBRATION

KEY .

• Follow the series of instructions displayed.

The counted wheel impulses will be displayed during the automatic calibration.

Weighing system

A weighing system is used to determine the amount of product in the bed. The weighing system must be calibrated and its taring point established.

Figure 3-23: Calibrate weighing system

Manual calibration

Manual calibration establishes the calibration based on user entered values.

Automatic calibration

If the Calibration figure for the Weighing system sensor is not known or to make sure the value is correct, automatic calibration establishes the calibration.

• To calibrate the Weighing system sensor, select CALIBRATION

KEY .

• Follow the series of instructions displayed.

Tare weighing system

Establishes the zero point or the starting point for the weighing system sensor. This point is determined by measuring the bed at empty.

• To calibrate the Weighing system sensor, select CALIBRATION

KEY .

• Follow the series of instructions displayed.

98-05173-EN R1

19

ISOBUS Job Computer: IC18 Spreader

Figure 3-25: Tare weighing system Spinner RPM alarm on/off

The Spinner RPM alarm will appear if the spinner RPM falls below the low limit level entered under spinner RPM trigger level. Select either “on” to activate the alarm, or “off” to deactivate the alarm.

The availability of a spinner RPM sensor is established in the OEM menu under sensors.

Spinner RPM trigger level

Spinner RPM trigger level establishes the low limit that will trigger the spinner RPM alarm.

Alarm configurations

Alarm configurations establishes alarms “on” or “off” as well as sets their trigger level.

Figure 3-26: Alarm configurations

OEM

The OEM setup menu is password protected and the settings in this menu are directly related to the fitted OEM equipment. To obtain an access code, contact your local dealer or TeeJet Technologies customer service.

NOTE: Some setup options are available or unavailable depending on the OEM settings. See the “Settings menu options table” for more information.

Figure 3-27: OEM – unlock

Amount remaining alarm on/off

The Amount remaining alarm will appear if the bed amount has reached the low limit level entered. Select either “on” to activate the alarm, or “off” to deactivate the alarm.

Amount remaining trigger level

Amount remaining trigger level establishes the low limit that will trigger the amount remaining alarm.

CAN speed source timeout

CAN speed source timeout establishes the number of seconds the system will continue to run on can speed without receiving can input before the alarm triggers.

Active trip count information

The Active trip count information alarm will appear on power up to identify to the user which trip counter is active and that this specific counter will be used for storing work data. Select either “on” to activate the alarm, or “off” to deactivate the alarm.

To access the OEM screens:

1. From the Main setup screen , select MACHINE.

2. Select OEM.

3. Select the Access Code Entry Box to the right of the menu option.

4. Use the number pad or slide bar to enter the access code.

5. Select the ACCEPT KEY to complete the unlock process

6. Select from:

►Sensors – used to establish the parameters for Spinner

RPM, Spinner RPM revolution, Hydraulic motor RPM revolution and Weighing systems and Tank empty sensor.

►Actuators – used to select the type of valve used to control the spreader belt and if a Dump valve is installed.

►User interface – used to establishes the displayed tolerance for application rate.

20 www.teejet.com

ISOBUS Job Computer: IC18 Spreader

►Regulator configuration – used to establish:

◄ Regulator test – used to verify the regulation control matches theory and actual settings.

◄ Valve configuration – sets the control settings for the regulation valve when the belt valve type is set to

Servo.

◄ PID parameters – sets the course, midrange and fine adjustments of the regulation valve.

◄ PWM signal – sets the PWM signal frequency; dutycycle maximum, offset and offset calibration RPM; and jitter frequency and amplitude when the belt valve type is set to PWM.

◄ Load valve parameters – establishes a valve parameter set when the belt valve type is set to PWM.

►Calibration RPM – used to programme the desired roller

RPM, the bed chain speed, used during the calibration process.

►Programme modes – used to designate various options that impact system functions including programme style, calibration type, flow factor, step percentage and fast empty working width reduction and adding a campaign count password.

►Delete total counters – used to clear the Total count system counter for Area, Amount and Time.

►TC - implement settings – used to establish implement geometry and connection type.

USER INTERFACE

User Interface allows the operator to select the system Universal Terminal (UT) if more than one UT is available on the ISOBUS CAN.

|

Counters

|

MAIN SETUP MODE MENU STRUCTURE

| | |

Job parameters Machine User interface Communications

|

Help

1. From the Main Setup Screen , select USER INTERFACE.

Figure 3-28: User Interface

Use preferred UT

Use preferred UT sets the UT preference to either “on” or “off”. If

“on” is selected, the preferred UT will be used. If “off” is selected, the system will arbitrarily select which UT to use (if more than one

UT is available on the ISOBUS CAN).

NOTE: This should always be set to “off” unless another UT is on the CAN bus.

98-05173-EN R1

21

ISOBUS Job Computer: IC18 Spreader

COMMUNICATION

Communication establishes the IC18's ability to communicate with an external computer.

|

Counters

|

MAIN SETUP MODE MENU STRUCTURE

Job parameters

|

Machine

1. From the Main Setup Screen , select COMMUNICATION.

Figure 3-29: Communication

|

User interface

|

Communications

|

Help

Amount of memory left

Displays the consoles memory availability for storage and file transfer.

NOTE: For more information about transfering data from a PC, please contact your local dealer or TeeJet Technologies

Customer Service.

HELP

The Help menu allows the operator to perform Diagnostics, access the About screen and reset the system to Factory Settings. These menus are typically accessed upon Customer Service personnel request only.

|

Counters

|

MAIN SETUP MODE MENU STRUCTURE

| | |

Job parameters Machine User interface Communications

|

Help

X Diagnostic

X About

X Factory settings

1. From the Main Setup Screen , select HELP.

2. Select from:

►Diagnostic – used to troubleshoot input/output of the controller (sensor or actuator).

►About – provides information on the console such as software version, serial number, CAN BUS information, etc.

►Factory settings – used to reset the system to factory default settings.

Figure 3-30: Help

22 www.teejet.com

ISOBUS Job Computer: IC18 Spreader

Diagnostic

Diagnostic is used to troubleshoot input/output of the controller

(sensor or actuator).

►Test input – displays the input high and low values on the installed sensors.

►Test output – allows the regulation valve to be tested at different percentages of duty cycle.

►UT – provides information regarding the universal terminal (UT) controller.

►TECU – provides information regarding the tractor electronic control unit (TECU).

Figure 3-31: Diagnostic

Test output

Test Output allows the regulation valve to be tested at different percentages of duty cycle.

Test PWM duty cycle

Liquid Valve PWM duty cycle is used to test the regulating valve at different percentages of duty cycle.

• Press the PLUS/MINUS KEYS to test the regulation valve at the specified duty cycle percentage increase/ decrease.

Figure 3-33: Test Output

Test input

Test input displays the input high and low values on the installed sensors.

• To reset the sensors to “0”, select RECYCLE BIN KEY .

• Follow the series of instructions displayed.

Figure 3-32: Test input

UT data

The UT menu provides information regarding the universal terminal controller (i.e., address version, etc.).

• If more terminals/controllers are used, switch between these by pressing the GO TO NEXT UT KEY .

• Press the DELETE OBJECT POOL KEY to force the UT to delete saved data and upload new information from the IC18 job computer on the next power cycle.

NOTE: Restart the IC18 job computer to implement and display changes.

Figure 3-34: UT data

98-05173-EN R1

23

ISOBUS Job Computer: IC18 Spreader

TECU

The tractor electronic control unit (TECU) is a control unit, residing on the tractor, that performs basic functions such as power handling, speed info, etc. The TECU data is displayed on this page.

Figure 3-35: TECU data

Factory settings

The Factory settings screen resets both machine and user settings to default settings from the factory.

Figure 3-37: Factory settings

About

The About screen provides information on the IC18 such as software version, build number, etc. This information may become useful in case of technical support.

Figure 3-36: About

24 www.teejet.com

ISOBUS Job Computer: IC18 Spreader

SETTINGS MENU OPTIONS

The main settings menu contains six (6) options: Counters, Job parameters, Machine, User interface, Communication and Help. Each of these options either directly access settings or additional menus. The table below outlines the additional menus, options available on that menu item, and directs you to the setup pages for further information.

Settings menu options legend:

= Sensor configuration, = Actuator configuration, = Program modes,  = Menu item always available

* Option may also be set up from Operations screen

Spinner RPM sensor: On

Weighing system: Off

Weighing system: On

Belt valve type: PWM (motor driven)

Belt valve type: Servo (coil based)

Program style: European mode

Program style: North American mode

Calibration type: Weight based

Calibration type: Volume base

Flow correction type: Flow factor

Flow correction type: Calibration number

Step percent: On

Work width reduction: On

Campaign count password: On

Counters

Job parameters –

Machine

Trip

Campaign

Area

Amount

Time

Password to clear

Total

Export

Active trip counter

Application rate

Tonnage

Bed size

Gate height

Density

Flow factor

*Filling

Operation –

Application rate step

Speed source

Simulated speed

Working width step

Implement Parameters

Calibrations

– *Application rate

Impulses per volume

Volume per impulse

Amount per impulse

Hydraulic system

Implement speed sensor

Weighing system

Expected application rate

Actual application rate

Active flow factor

Corrected flow factor

Active calibration number

Corrected calibration number

(Continued on next page)

98-05173-EN R1

25

ISOBUS Job Computer: IC18 Spreader

Machine

(Continued)

User Interface

Communication

Help

Alarm

Configurations

Amount remaining alarm on/off

Amount remaining trigger level

CAN speed source timeout

Active trip count information

Spinner RPM alarm

Sensors

Actuators

User interface

Regulator test

Valve configuration

OEM

Regulator

Configurations

– PID parameters

Calibration RPM

Program modes

Reference gate height

Clear total counters

TC-implement settings

PWM signal

Load valve parameters

Coarse adjustment

Fine adjustment

Midrange adjustment

26 www.teejet.com

ISOBUS Job Computer: IC18 Spreader

CHAPTER 4 – TRANSPORT MODE

While in Transport mode, all operation functions are locked “off” and cannot be activated. Transport mode displays the speed in analogue mode.

Figure 4-1: Transport mode from the Home screen

Figure 4-2: Transport mode

Home - Exits Transport mode and gives access to the IC18’s available functions: Operation mode, Transport mode and Main setup

Speedometer

98-05173-EN R1

27

ISOBUS Job Computer: IC18 Spreader

CHAPTER 5 – HOME SCREEN SHORTCUTS

Fast empty key shortcut

The FAST EMPTY SHORTCUT KEY allows the user to empty the hopper of its contents without having the spinners on.

• Press the FAST EMPTY SHORTCUT KEY .

• Follow instructions on screen.

Figure 5-1: Fast empty key

Figure 5-2: Filling shortcut key

Filling shortcut key

When available, FILLING SHORTCUT KEY gives the user quick access to and from the filling options.

Weighing system sensor activated

Fill hopper access key unavailable – When a weighing system sensor is installed and activated, the hopper amount is determined by the sensor.

Weighing system sensor not activated

Filling shortcut key available – the Filling shortcut key gives one press access to the Filling menu. There the amount of material remaining in the hopper is established and/or the amount remaining value can be reset to the maximum volume of the hopper.

• Press the FILLING SHORTCUT KEY .

• Press Amount remaining to manually adjust the amount in the hopper.

• Press the FULL HOPPER KEY to set to full amount.

The size of the hopper is established under Machine -> OEM ->

Hopper size. This is the number that will repopulate when the FULL

HOPPER KEY is pressed.

Application rate shortcut key

The APPLICATION RATE SHORTCUT KEY gives the user access to calibrate the Active flow factor. For more information, see

Main setup-> Machine-> Calibrations-> Application rate.

Figure 5-3: Application rate shortcut key

28 www.teejet.com

ISOBUS Job Computer: IC18 Spreader

CHAPTER 6 – OEM OPTIONS

The OEM setup menu is password protected and the settings in the menu are directly related to the fitten OEM equipment. Contact the manufacturer or local dealer for service.

NOTE: Some setup options are available or unavailable depending on the OEM settings. See the “Settings Menu Options Table” for more information.

|

Counters

|

MAIN SETUP MODE MENU STRUCTURE

| | |

Job Parameters Machine User Interface Communications

|

Help

X *Filling

X Operation

X Implement Parameters

X Calibrations

X Alarm Configurations

T OEM

X Sensors

X Actuators

X User Interface

X Regulator Configuration

X Calibration RPM

X Program Modes

X Delete Total Counters

X TC - Implement Settings

The OEM setup menu is password protected and the settings in this menu are directly related to the fitted OEM equipment.

*Menu settings directly related to OEM equipment.

1. From the Main Setup Screen , select MACHINE.

2. Select OEM.

3. Select the Access Code Entry Box to the right of the menu option.

4. Use the number pad or slide bar to enter the access code.

5. Select the ACCEPT KEY to complete the unlock process

6. Select from:

►Sensors – used to establish the parameters for Spinner RPM, Spinner RPM Revolution, Hydraulic Motor RPM Revolution and

Weighing systems and Tank Empty Sensor.

►Actuators – used to select the type of valve used to control the spreader belt and if a Dump Valve is installed.

►User Interface – used to establishes the displayed tolerance for application rate.

►Regulator Configuration – used to establish:

◄Regulator Test – used to verify the regulation control matches theory and actual settings.

◄Valve Configuration – sets the control settings for the regulation valve when the belt valve type is set to Servo.

◄PID Parameters – sets the course, midrange and fine adjustments of the regulation valve.

◄PWM Signal – sets the PWM signal frequency; duty cycle maximum, offset and offset calibration RPM; and jitter frequency and amplitude when the belt valve type is set to PWM.

◄Load Valve Parameters – establishes a valve parameter set when the belt valve type is set to PWM.

►Calibration RPM – used to program the desired roller RPM, the bed chain speed, used during the calibration process.

►Program Modes – used to designate various options that impact system functions including program style, calibration type, flow factor, step percentage and fast empty working width reduction and adding a campaign count password.

►Delete Total Counters – used to clear the Total Count system counter for Area, Amount and Time.

►TC - Implement Settings – used to establish implement geometry and connection type.

98-05173-EN R1

29

ISOBUS Job Computer: IC18 Spreader

Figure 6-1: OEM Weighing System

Weighing System sets the associated sensor availability to “On” or “Off”. When on, the Weighing System option is displayed on the

Calibrations menu and the Fill Bed Access Key is not available on the Home Screen.

Tank Empty Sensor

Tank Empty Sensor sets the associated sensor availability to off or two different on options:

◄Off – sensor is deactivated

◄Warning On Signal – sensor gives an alert when fertilizer covers the sensor

◄Warning On No Signal – sensor gives an alert when it has no fertilizer covering the sensor

Actuators

Actuators is used to select the type of valve used to control the spreader belt.

Figure 6-3: Actuator Configuration

Sensors

Sensors establishes the parameters for Spinner RPM, Spinner RPM

Revolution, Hydraulic Motor RPM Revolution, Weighing systems and Tank Empty. If the fitted sensors are not registered here, the sensor options will not be available in the calibration menus.

Figure 6-2: Sensor Configuration

Spinner RPM Sensor

Spinner RPM Sensor sets the associated sensor availability to “On” or “Off”.

Spinner RPM Pulses per Revolution

Spinner RPM Pulses/Revolution establishes the number of pulses per one (1) revolution for the Spinner RPM sensor.

Hydraulic Motor RPM Pulses per Revolution

Hydraulic Motor RPM Pulses/Revolution establishes the number of pulses per one (1) revolution of the hydraulic motor.

Belt Valve Type

Belt Valve Type establishes the type of valve used to control the spreader belt. If a PWM valve is being used, select “PWM (Moter

Driven)”. If a servo valve is being used, select “Servo (Coil Based)”.

Dump Valve Installed

Dump Valve Installed sets the associated valve availability to “On” or “Off”. Dump Valve can be used with a PWM or a Servo valve.

The Dump Valve diverts oil from the regulation valve to stop the belt. When the Dump Valve is installed and activated, the regulation valve will hold its position when the Master Switch is used to stop product application. When the Master Switch is pressed to begin product application, the Dump Valve will close and allow oil to flow to the regulation valve; therefore, the belt/chain will begin to rotate.

30 www.teejet.com

ISOBUS Job Computer: IC18 Spreader

Figure 6-5: Regulator Configuration - Regulator Test

User Interface

User Interface establishes the displayed tolerance for application rate (displayed deadband).

Figure 6-4: User Interface

Application Rate Display Deadband

Application Rate Display Deadband is a deadband used for shifting between showing Target Application Rate vs. Actual Application

Rate while spreading. Once actual application rate gets within the set percentage of the target applicaiton rate, target applicaiton rate is shown.

Regulator Configuration

Regulator Configuration establishes the following:

►Regulator Test – used to verify the regulation control matches theory and actual settings

►Valve Configuration (Belt Valve Type: Servo) – sets the control settings for the regulation valve

►PID Parameters – sets the course and fine adjustments of the regulation valve.

►PWM Signal (Belt Valve Type: PWM) – sets the control settings for the PWM Proportional valve

►Load Valve Parameters (Belt Valve Type: PWM) – allows

OEM selection between pre-set P, I and D values (PID

Parameters sets the course, fine and midrange adjustments of the regulation valve)

Regulator Test

The regulator test is used to verify the regulation control matches theory and actual settings.

Figure 6-6: Regulator Test

RPM Reference

RPM Reference displays the actual RPM for the given setpoint and duty cycle being tested.

Actual Duty Cycle

Actual Duty Cycle displays the actual duty cycle used during the regulator test.

RPM Setpoint

The RPM Setpoint is the RPM at which the Regulator Test will simulate the belt roller RPM.

98-05173-EN R1

31

ISOBUS Job Computer: IC18 Spreader

Duty Cycle Step Percent

The Duty Cycle Step Percent is the percentage of increase/ decrease in the RPM setpoint for the regulation test.

Fine Adjustment

Fine Adjustment is the integral control (very small adjustment) of the regulator valve.

Valve Configuration (Belt Valve Type: Servo)

Valve Configuration sets the control settings for the regulation valve.

Available with OEM-> Actuators-> Belt Valve Type: Servo.

Figure 6-7: Valve Configuration

PWM Signal (Belt Valve Type: PWM)

PWM Signal sets the control settings for the PWM Proportional valve.

Available with OEM-> Actuators-> Belt Valve Type: PWM.

Figure 6-9: PWM Signal

Minimum Regulation Voltage

Minimum Regulation Voltage sets the minimum voltage required to actuate the regulation valve.

Regulation Backlash

Regulation Backlash sets the amount of time needed for the regulation valve to begin moving after a direction change.

Regulation Deadband

Regulation Deadband sets the tolerance between actual and target rates for the regulation valve.

PID Parameters

PID Parameters sets the course, fine and midrange adjustments of the regulation valve.

Figure 6-8: PID Parameters

Signal Frequency

Signal Frequency sets the recommended operating PWM frequency.

Maximum Duty Cycle

Maximum duty cycle sets the maximum amout of drive used by the regulator. Controlling output above this percentage has no effect on oil-flow through the valve.

Duty Cycle Offset

Duty cycle offset (minimum duty cycle) sets the minimum amout of drive used by the regulator. Controlling output below this value has no effect on oil-flow through the valve.

• To calibrate the PWM offset, select CALIBRATION KEY .

• Use the PLUS/MINUS KEYS to increase or decrease the PWM offset percentage.

• Select the ACCEPT KEY to save the selected percentage.

Course Adjustment

Course Adjustment is the proportional control (large adjustments) of the regulator valve.

32 www.teejet.com

Figure 6-10: PWM Offset Calibration Procedure

ISOBUS Job Computer: IC18 Spreader

Load Valve Parameters (Belt Valve Type: PWM)

Load Valve Parameters allows OEM selection between pre-set P, I and D values (PID Parameters sets the course, fine and midrange adjustments of the regulation valve).

Available with OEM-> Actuators-> Belt Valve Type: PWM.

Figure 6-11: Load Valve Parameters

Jitter Frequency (Dither Frequency)

Jitter Frequency (Dither Frequency is a frequency superposed on top of the IC18 control output to help avoid stiction in the PWM proportional valve. Some Proportional valves requires this.

Jitter Amplitude (Dither Amplitude)

Jitter Amplitude (Dither Amplitude) is an amplitude superposed on top of the IC18 control output to help avoid stiction in the PWM proportional valve. Some Proportional valves requires this.

Duty Cycle Offset Calibration RPM

Duty Cycle Offset Calibration RPM value is used while making a Hydraulic Calibration (Main Setup-> Machine-> Calibration->

Hydraulic Calibration). Once calibration is started, the roller RPM has to reach this minimum value within 10 seconds, else a warning will appear. This is to make sure tractor is providing enough hydraulic oil to make a valid Hydraulic Calibration.

NOTE: Main Setup-> Machine-> Calibration-> Hydraulic Calibration is used to automatically determine OEM-> Regulation

Configuration> PWM Signal> “Maximum Duty Cycle” and

“Duty Cycle Offset” values.

Valve Parameter Set

Valve Parameter Set establishes the pre-set values from either of two specific PWM proportional valve models: “Berendsen SR10” and “Danfoss PB12”.

Calibration RPM

Calibration RPM is used to program the desired roller RPM, and the

Calibration RPM Step percentage.

Figure 6-12: Calibration RPM

Calibration RPM

Calibration RPM is used to program the desired roller RPM while making a Volume/pulse calibration (Machine-> Calibration-> Volume per pulse).

Calibration RPM Step

Calibration RPM Step is used to change the roller RPM in steps while making a Volume/pulse calibration.

98-05173-EN R1

33

ISOBUS Job Computer: IC18 Spreader

Program Modes

Program Modes is used to designate various options that impact system functions.

NOTES: Program modes settings should not be changed without consulting TeeJet Technologies.

Figure 6-13: Program Modes

Work Width Reduction

Work Width Reduction sets the availability of the keys for changing current work width to appear on the Operation Screen. These keys will allow the operator to manually change the current working width if spreading into a wedge pattern field/track. Changes happens is steps of +/- 2 meter.

Campaign Count Password

Campaign Count Password establishes if a password is required to clear the Campaign Counters.

Reference Gate Height (Program Style:

North America)

Reference Gate Height establishes the actual gate height (in inches) used during the calibration process. The calibration process uses one Reference Gate Height to calculate calibration values for all the various gate height settings. During the calibration process, the actual gate height used on the spreader and the Reference

Gate Height must be the same. Performing a calibration using an actual gate height that is different than the Reference Gate Height will result in an incorrect calibration and may cause product to be misapplied. Available only in Program Style: North America.

Figure 6-14: Reference Gate Height

Program Style

Program Style establishes how calibrations are configured.

◄European – Gate Height is NOT calculated into the product application and calibrations will be based on volume per pulse.

◄North America – Gate Height is calculated into the product application and calibrations will be based on pulses per volume.

Calibration Type

Calibration Type establishes if your system is volume or weight based.

Flow Correction Type

Flow Correction Type establishes if a flow factor or calibration number will be used. If “Flow Factor” or “Calibration Number” is selected, Main Menu-> Machine-> Calibrations-> Application Rate will be available.

Step Percent

Step percent sets the associated menu option to “On” or “Off”.

Target Rate Percentage Increase/Decrease Keys increase/ decrease the application target rate per this established step percentage set in the Machine Operation setup screen under

Application Rate Step. Automatic regulation mode will automatically adjust the application rate based on the current speed in reference to the target rate.

Fast Empty

Fast Empty sets the associated menu option to “On” or “Off”. The

Fast Empty Key allows the user to empty the hopper of its contents without having the spinners on.

34 www.teejet.com

ISOBUS Job Computer: IC18 Spreader

Clear Total Counters

Clear Total Counters clears the Total Count system counter for

Area, Volume and Time back to the default settings of “0”.

• To clear the total counters, select TRASH CAN KEY . A confirmation screen will be displayed.

Figure 6-15: Clear Total Counters

TC-Implement Settings

TC-Implement Settings establishes the connector type and associated offsets between the vehicle and the implement

Figure 6-16: TC-Implement Settings

Area

Displays total applied area for all trips.

Volume

Displays total volume of material applied during all trips.

Time

Displays total time traveled for all trips.

A = Connection x-offset

Measured in parallel to the centerline of the machine, defines the distance from the connection point to the center of the front axle of trailed implement..

B = Section x-offset

Measured in parallel to the centerline of the machine, defines the distance from the center of the front axle of trailed implement to the center of the section length (C).

C = Section Length

Measured in parallel to the centerline of the machine, defines the length of application for the section(s).

Connection Type

Connection Type establishes the type of connection between the vehicle and the implement.

Different machines have different options. The following machines are detailed in this manual. Contact your TeeJet dealer for information on your specific setup or if there are any questions.

• Unknown

• Tractor Drawbar

• 3-point Hitch Semi

• 3-point Hitch

• Hitch Hook

• Clevis Coupling

• Piton Coupling

• CUNA or Pivot Hitch

• Ball Type

Review the Help Screen for more information about each connection type.

98-05173-EN R1

35

ISOBUS Job Computer: IC18 Spreader

– Connection x-offset

– Section x-offset

– Section Length

Connection Types:

• Unknown

• Tractor Drawbar

• 3-point Hitch Semi

• Hitch Hook

• Clevis Coupling

• Piton Coupling

• CUNA or Pivot Hitch

• Ball Type

– Section x-offset

– Section Length

Connection Types:

• 3-point Hitch

36 www.teejet.com

ISOBUS Job Computer: IC18 Spreader

APPENDIX A - FACTORY SETTINGS & RANGES

JOB PARAMETERS

Description

Active trip counter

Factory setting

1

Range/options

1 - 10

7

8

5

6

3

4

User setting

1

2

9

10

Application rate

Tonnage

Density

Flow factor

MACHINE

0.0 kg/ha

Off

0.00 kg/l

1.00

0.0 - 9999 kg/ha

Off

On

0.00 - 5.00 kg/l

0.2 - 2.00

Filling

Description

Amount remaining

Factory setting

8000 kg

Range/options

0 - 45000 kg

User setting

Operation

Description

Application rate step

Speed source

Factory setting

0%

CAN

Range/options

0-99 %

CAN

Implement

Simulated

0.0 - 99.9 km/h

User setting

Simulated speed 0.0 km/h

Implement parameters

Description

Working width

Fast empty bed RPM

Master switch

Factory setting

12.2 m

50 RPM

Console

Range/options

0.0 - 90.0 m

0 - 9999 RPM

Remote switch console

User setting

98-05173-EN R1

37

ISOBUS Job Computer: IC18 Spreader

Calibrations

Volume per impulse

Description

Volume per impulse

Factory setting

0.0 cm 3 /impulse

Range/options

0.0 - 1500.0 cm 3 /impulse

User setting

Amount per impulse

Description

Amount per impulse

Implement speed sensor

Description

Impulses per distance

Alarm configurations

Description

Amount remaining alarm on/off

Factory setting

0.0 g/pulse

Factory setting

0

Factory setting

Off

Range/options

0.0 - 999.99 g/pulse

Range/options

0 - 40000 /100 m

User setting

User setting

User setting

Amount remaining trigger level

Can speed source timeout

Active trip count information

Spinner RPM alarm on/off

Spinner RPM trigger level

0 kg

4 sec

Off

Off

0 RPM

Range/options

On

Off

0 - 4500 kg

0 - 999 sec

On

Off

On

Off

0 - 9999 RPM

USER INTERFACE

Description

Use preferred UT

Factory setting

Off

Range/options

Off

On

User setting

38 www.teejet.com

ISOBUS Job Computer: IC18 Spreader

APPENDIX B - UNIT SPECIFICATIONS

Dimensions

Weight

Connector

Environmental Operating

Humidity

Input/output

Power requirement

19.05 x 18.42 x 6.03 cm

0.644kg

30 position Cinch pins. A1-K3

30 position Cinch pins. L1-Y3

-40 to +85°C

90% non-condensing

ISO 11783 (ISOBUS)

<9 watts @12 VDC

98-05173-EN R1

39

TeeJet Technologies www.teejet.com

98-05271-EN-A4 R1 English-International