- No category
advertisement
GOT2000 Series
Video/RGB Input Unit
User's Manual
GT27-V4-Z
Set of GT16M-V4-Z and GT27-IF1000
GT27-V4R1-Z
Set of GT16M-V4R1-Z and GT27-IF1000
GT27-R2-Z
Set of GT16M-R2-Z and GT27-IF1000
Thank you for purchasing the GOT2000 Series.
Prior to use, please read both this manual and detailed manual thoroughly to fully understand the product.
MODEL
MODEL
CODE
GT27-V4R1-Z-U-JE
1D7ML4
IB(NA)-0800519-B(1407)MEE
SAFETY PRECAUTIONS
(Always read these precautions before using this equipment.)
Before using this product, please read this manual and the relevant manuals introduced in this manual carefully and pay full attention to safety to handle the product correctly.
The precautions given in this manual are concerned with this product.
In this manual, the safety precautions are ranked as "WARNING" and "CAUTION".
WARNING
Indicates that incorrect handling may cause hazardous conditions, resulting in death or severe injury.
CAUTION
Indicates that incorrect handling may cause hazardous conditions, resulting in medium or slight personal injury or physical damage.
Note that the circumstances.
CAUTION level may lead to a serious accident according to the
Always follow the precautions of both levels because they are important to personal safety.
Please save this manual to make it accessible when required and always forward it to the end user.
[DESIGN PRECAUTIONS]
CAUTION
Do not bunch the control wires or communication cables with the main circuit or power wires, or lay them close to each other.
As a guide, separate the lines by a distance of at least 100mm (3.94 inches) otherwise malfunctions may occur due to noise.
[INSTALLATION PRECAUTIONS]
WARNING
Be sure to shut off all phases of the external power supply used by the system before mounting or removing this unit to/from the GOT. Not doing so can cause a unit failure or malfunction.
Before connecting the Bus connection cable to this unit, always shut off GOT power and PLC CPU power externally in all phases.Not doing so can cause a malfunction.
CAUTION
Use this unit in the environment that satisfies the general specifications described in the User's Manual for the GOT used. Not doing so can cause an electric shock, fire, malfunction or product damage or deterioration.
Do not drop the unit or subject it to string shock.
A unit damage may result.
When installing this unit to the GOT, fit it to the connection interface of the
GOT and tighten the mounting screws in the specified torque range (0.36
N•m to 0.48 N•m) with a Phillips-head screwdriver No.2.
Undertightening can cause a drop, failure or malfunction. Overtightening can cause a drop, failure or malfunction due to screw or unit damage.
[WIRING PRECAUTIONS]
WARNING
Be sure to shut off all phases of the external power supply used by the system before wiring.
Failure to do so may result in an electric shock, product damage or malfunctions.
CAUTION
Exercise care to avoid foreign matter such as chips and wire offcuts entering the unit.
Not doing so can cause a fire, failure or malfunction.
Make sure to securely connect the cable to the connector of unit.
Incorrect connection may cause malfunctions.
[STARTUP AND MAINTENANCE PRECAUTIONS]
WARNING
Before starting cleaning, always shut off GOT power externally in all phases.
Not doing so can cause a unit failure or malfunction. Undertightening can cause the GOT to drop, short circuit or malfunction.
Overtightening can cause a short circuit or malfunction due to the damage of the screws or unit.
Do not disassemble or modify any unit.
This will cause failure, malfunction, injuries, or fire.
Do not touch the conductive areas and electronic parts of this unit directly.
Doing so can cause a unit malfunction or failure.
CAUTION
Always secure the cables connected to the unit, e.g. run them in conduits or clamp them. Not doing so can cause unit or cable damage due to dangling, moved or accidentally pulled cables or can cause a malfunction due to a cable contact fault.
Do not hold the cable part when unplugging any cable connected to the unit.
Doing so can cause unit or cable damage or a malfunction due to a cable contact fault.
Always make sure to touch the grounded metal to discharge the electricity charged in the body, etc., before touching the unit. Failure to do so may cause a failure or malfunctions of the unit.
[DISPOSAL PRECAUTIONS]
CAUTION
Dispose of this product as industrial waste.
[TRANSPORTATION PRECAUTIONS]
CAUTION
Make sure to transport the GOT main unit and/or relevant unit(s) in the manner they will not be exposed to the impact exceeding the impact resistance described in the general specifications of the User's Manual for the GOT used, as they are precision devices.
Failure to do so may cause the unit to fail.
Check if the unit operates correctly after transportation.
[TRANSPORTATION PRECAUTIONS]
CAUTION
When fumigants that contain halogen materials such as fluorine, chlorine, bromine, and iodine are used for disinfecting and protecting wooden packaging from insects, they cause malfunction when entering our products.
Please take necessary precautions to ensure that remaining materials from fumigant do not enter our products, or treat packaging with methods other than fumigation (heat method).
Additionally, disinfect and protect wood from insects before packing products.
Manuals
The following shows manuals relevant to this product.
Detailed Manual
Manual name
GOT2000 Series User's Manual (Hardware)
(Sold separately)
Manual number
(Model code)
SH-081194ENG
(1D7MJ5)
GOT2000 Series Connection Manual
(Microcomputers, MODBUS Products,
Peripherals) For GT Works3 Version1
SH-081200ENG
(1D7MK2)
For detailed manuals, refer to the PDF manuals stored in the DVD-ROM for the drawing software used.
Relevant Manuals
For relevant manuals, refer to the Help or the :PDF manuals stored in the DVD-
ROM for the drawing software used.
The latest manuals are also available from MITSUBISHI ELECTRIC FA Global
Website (http://www.MitsubishiElectric.co.jp/fa/).
© 2013 MITSUBISHI ELECTRIC CORPORATION
Compliance with the EMC and Low Voltage
Directives
To configure a system meeting the requirements of the EMC and Low Voltage
Directives when incorporating the Mitsubishi GOT (EMC and Low Voltage
Directives compliant) into other machinery or equipment, refer to "EMC AND LOW
VOLTAGE DIRECTIVES" of the General Description included with the GOT used.
The CE mark, indicating compliance with the EMC and Low Voltage Directives, is printed on the rating plate of the GOT.
Packing List
After unpacking the box, check that the following products are included.
Model Product Quantity
GT16 Video input unit GT16M-V4-Z 1
GT27-V4-Z Video Interface Converter Unit GT27-IF1000
Mounting screw set (2 screws (26mm), 2 stickers)
1
4
GT27-V4R1-Z
GT27-R2-Z
GT16 Video/RGB input unit GT16M-V4R1-Z
Video Interface Converter Unit GT27-IF1000
Mounting screw set (2 screws (26mm), 2 stickers)
GT16 RGB input unit GT16M-R2-Z
Video Interface Converter Unit GT27-IF1000
Mounting screw set (2 screws (26mm), 2 stickers)
4
1
1
1
1
4
1. OVERVIEW
This User's Manual describes the following units.
When mounting the following units with the GT27, the GOT can display video images taken by a camcorder or a RGB screen.
• The GT 27 video input unit GT27-V4-Z (hereinafter referred to as the video input unit) is configured with the GT 16 video unit and the Video Interface Converter
Unit.
For the video input unit, the GOT can display video images taken by up to four camcorders.
• The GT 27 video/RGB input unit GT27-V4-Z (hereinafter referred to as the video/RGB input unit) is configured with the GT16 video/RGB input unit and the
Video Interface Converter Unit.
For the video/RGB input unit, the GOT can display video images taken by up to four camcorders or a RGB screen for up to one device for the RGB input.
• The GT27 RGB input unit GT27-R2-Z (hereinafter referred to as the RGB input unit) is configured with the GT16 RGB input unit and the Video Interface
Converter Unit.
For the RGB input unit, the GOT can display only one RGB screen by switching up to two video input channels.
For the video input with using the above units, the GOT can be used as a vision sensor monitor.
For the RGB input unit with using the above units, the units can be used as the
RGB output type vision sensor.
GOT *1
A 1254
B 348
GT27-V4R1-Z
注意 CAUTION
誤動作の 恐れあり
通電中 着脱しないでください
Do not mount not desmount supplied.
Video camera
*1*2
Personal computer *3*4 PLCs for line control
* 1:Power on the GOT simultaneously with the camcorder.
*2:Depending on the camcorder type, noise from the power supply cable of the camcorder may cause malfunction of the GOT or a programmable controller.
In this case, attach the following line filter to the power supply line of the camcorder.
Recommended line filter: TDK-Lambda RSHN-2003 (or equivalent products)
*3:If the flickering of the screen occurs due to the noise from the RGB cable, attach the following ferrite core to the RGB input section.
Recommended ferrite core: TDK-Lambda ZCAT3035-1330 (or equivalent products)
*4:When connecting any of the above units to a personal computer, ground the ground cable of the personal computer.
To use the video input unit, video/RGB input unit, and RGB input unit, set the controller settings.
For the settings and system configurations, refer to GOT2000 Series Connection
Manual (Microcomputer, MODBUS Products, Peripherals) for GT Works3 Version
1.
For the details of the video input, video/RGB input, and RGB input function, refer to
GT Designer3 (GOT2000) Help.
2. SPECIFICATIONS
The performance specifications of the video input unit, video/RGB input unit, and RGB input unit are indicated below.
The general specifications of the video input unit, video/RGB input unit, and RGB input unit are the same as those of the GOT.
Refer to the User's Manual for the GOT used for the general specifications of the
GOT.
Video input section *2
RGB input section
Item
GT16M-V4
NTSC format, PAL format(interlaced format)
EIA format, CCIR format
(interlaced format)
Specifications
GT16M-V4R1
Video input format
Color
Number of video input channels
Input signal
Monochro me
4 channel
Display size
IVp-p, 75
640
768
, composite signal
480 dot
576 dot, 720 480 dot *1
Connector for external connection
BNC connector
RGB input method -
GT16M-R2
-
-
-
-
-
-
Analog RGB(XGA:1024 768 dot,
SVGA: 800 600 dot,
VGA:640 480 dot)
Number of video input channels
Input image signal
Synchronizing signal
Display size -
-
-
1 channel
1Vp-p, 75
TTL, 1k
2 channels
*3
1024 768 dot (refresh rate 60Hz)
800 600 dot (refresh rate 60, 72,
75Hz)
640 480 dot (refresh rate 60, 72,
75, 85Hz)
Connector for external connection D-Sub15 pin: female
3.3
VDC
0.32A
0.51A
0.49A
Internal current consumption
Weight
5.0
VDC
0.34A accompanied with the
GT27-IF1000
0.34kg accompanied with the
GT27-IF1000
0.39A accompanied with the GT27-
IF1000
0.36kg accompanied with the GT27-
IF1000
0.35A accompanied with the
GT27-IF1000
0.33kg accompanied with the GT27-IF1000
*1:Compatible with PAL and CCIR formats only.
*2:The GOT cannot display both video images and RGB screens at the same time.
*3:The GOT can display only one RGB screen.
3. PART NAMES AND EXTERNAL
DIMENSIONS
3.1 GT16 Video/RGB Input Unit, GT16 Video
Input Unit, and GT16 RGB Input Unit
The external dimensions for all the units are the same except the connector dimensions of the video input section and the RGB input section.
GT16M-V4R1-Z
1)
133 (5.24)
2) GT16M-V4R1-Z
GT16M-V4-Z
GT16M-R2-Z
3)
2)
7) GT16M-V4R1-Z
7)
6)
GT16M-V4-Z
18
(0.71)
18
(0.71)
34
(1.34)
26
(1.02)
19
(0.75)
5)
4)
44.5 (1.75)
GT27-IF1000
GOT main unit
6)
GT16M-R2-Z
18
(0.71)
18
(0.71)
34
(1.34)
45
(1.77)
5)
4)
No.
1)
2)
3)
4)
5)
6)
7)
6)
Name
Extension connector
Mounting screw
68.5
(2.70)
19
(0.75)
5)
Description
Unit : mm (inch)
Connector for connecting an extension unit
Screw for fixing the Video Interface Converter Unit
Rating plate -
Connector for RGB input Connector for connecting 9-core combined cables
Video connector
Interface connector
Video connector connected to the Video Interface
Converter Unit
Connector connected to the Video Interface Converter
Unit
Connector for video input Connector for connecting a coaxial cable
3.2 Video Interface Converter Unit
3)
4)
2)
21.5 (0.85)
6)
No.
1)
2)
3)
Name
Extension connector
Mounting screw
Rating plate
4) Video connector
5)
6)
Auxiliary extension connector
Interface connector
Unit : mm (inch)
5)
Description
Connector for connecting the GT16 Video/RGB Input
Unit, GT16 Video Input Unit, or GT16 RGB Input Unit
Screw for fixing the GOT
-
Video connector for connecting the GT16 Video/RGB
Input Unit, GT16 Video Input Unit, or GT16 RGB
Input Unit
Auxiliary extension connector connected to the GOT
Extension connector connected to the GOT
4. INSTALLATION AND REMOVAL PRO-
CEDURE
4.1 Unit Installation
The installation procedure for the video/RGB input unit is explained using the
GT2712.
1) Turn off the GOT.
2) Pull up the two hooks in the extension unit cover (two covers) of the GOT to remove the cover toward the opposite side of the hoots of the cover as a fulcrum.
3) Connect the Video Interface Converter Unit to the auxiliary extension interface and the extension interface on the GOT. After connecting it, tighten four mounting screws (26mm) with a torque of 0.36N•m to 0.48N•m to fix the unit.
4)The connector for video input has the protection cap.
Remove the protection cap for the connector to be used.
(Store the removed protection cap.)
5) Fit the GT16 video/RGB input unit n the Video Interface Converter Unit case.
6) Tighten four mounting screws (40mm) of GT16 video/RGB input unit with a torque of 0.36N•m to 0.48N•m to fix the unit.
8) For mounting no extension unit on the unit, cover over four mounting screws with the accessory stickers to the GT16 video/RGB input unit, the GT16 video/
RGB input unit, or the Video Interface Converter Unit to avoid static electricity.
Keep the connector cover fixed.
Keep all the stickers fixed.
Connector cover Accessory sticker
Sticker
Accessory sticker
4.2 Unit Removal
For removing the Video/RGB Input Unit, Video Input Unit, and RGB Input Unit, reverse the procedure of the installation.
Warranty
Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi; machine damage or lost profits caused by faults in the Mitsubishi products; damage, secondary damage, accident compensation caused by special factors unpredictable by Mitsubishi; damages to products other than
Mitsubishi products; and to other duties.
For safe use
• This product has been manufactured as a general-purpose part for general industries, and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life.
• Before using the product for special purposes such as nuclear power, electric power, aerospace, medicine or passenger movement vehicles, consult with Mitsubishi.
• This product has been manufactured under strict quality control.
However, when installing the product where major accidents or losses could occur if the product fails, install appropriate backup or failsafe functions in the system.
Country/Region Sales office/Tel
Italy
Spain
U.S.A
Brazil
Germany
U.K
Mitsubishi Electric Automation Inc.
500 Corporate Woods Parkway Vernon Hills, IL 60061, U.S.A.
Tel : +1-847-478-2100
MELCO-TEC Rep. Com.e Assessoria Tecnica Ltda.
Rua Correia Dias, 184, Edificio Paraiso Trade Center-8 andar
Paraiso, Sao Paulo, SP Brazil
Tel : +55-11-5908-8331
Mitsubishi Electric Europe B.V. German Branch
Gothaer Strasse 8 D-40880 Ratingen, GERMANY
Tel : +49-2102-486-0
Mitsubishi Electric Europe B.V. UK Branch
Travellers Lane, Hatfield, Hertfordshire., AL10 8XB, U.K.
Tel : +44-1707-276100
Mitsubishi Electric Europe B.V. Italian Branch
Centro Dir. Colleoni, Pal. Perseo-Ingr.2
Via Paracelso 12, I-20041 Agrate Brianza., Milano, Italy
Tel : +39-039-60531
Mitsubishi Electric Europe B.V. Spanish Branch
Carretera de Rubi 76-80,
E-08190 Sant Cugat del Valles, Barcelona, Spain
Tel : +34-93-565-3131
France
South Africa
Hong Kong
Mitsubishi Electric Europe B.V. French Branch
25, Boulevard des Bouvets, F-92741 Nanterre Cedex, France
Tel : +33-1-5568-5568
Circuit Breaker Industries Ltd.
Private Bag 2016, ZA-1600 Isando, South Africa
Tel : +27-11-928-2000
Mitsubishi Electric Automation (Hong Kong) Ltd.
10th Floor, Manulife Tower, 169 Electric
Road, North Point, Hong Kong
Tel : +852-2887-8870
China
Taiwan
Korea
Mitsubishi Electric Automation (China) Ltd.
4/F Zhi Fu Plazz, No.80 Xin Chang Road,
Shanghai 200003, China
Tel : +86-21-6120-0808
Setsuyo Enterprise Co., Ltd.
6F No.105 Wu-Kung 3rd.Rd, Wu-Ku Hsiang,
Taipei Hsine, Taiwan
Tel : +886-2-2299-2499
Mitsubishi Electric Automation Korea Co., Ltd.
1480-6, Gayang-dong, Gangseo-ku Seoul
157-200,
Singapore
Tel : +82-2-3660-9552
Mitsubishi Electric Asia Pte, Ltd.
Thailand
Indonesia
307 Alexandra Road #05-01/02,
Mitsubishi Electric Building, Singapore 159943
Tel : +65-6470-2460
Mitsubishi Electric Automation (Thailand) Co., Ltd.
Bang-Chan Industrial Estate No.111 Moo 4, Serithai Rd,
T.Kannayao, A.Kannayao, Bangkok 10230 Thailand
Tel : +66-2-517-1326
P.T. Autoteknindo Sumber Makmur
Muara Karang Selatan, Block A/Utara
India
No.1 Kav. No.11 Kawasan Industri Pergudangan
Jakarta - Utara 14440, P.O.Box 5045 Jakarta, 11050 Indonesia
Tel : +62-21-6630833
Messung Systems Pvt, Ltd.
Electronic Sadan NO:III Unit No15, M.I.D.C Bhosari,
Pune-411026,
Australia
Tel : +91-20-2712-3130
Mitsubishi Electric Australia Pty. Ltd.
348 Victoria Road, Rydalmere, N.S.W 2116, Australia
Tel : +61-2-9684-7777
HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
NAGOYA WORKS : 1-14, YADA-MINAMI 5-CHOME, HIGASHI-KU, NAGOYA, JAPAN
When exported from Japan, this manual does not require application to the Ministry of Economy, Trade and Industry for service transaction permission.
Specifications subject to change without notice.
Printed in Japan, July 2014.
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project