USER MANUAL FOR 

DMX4i / DMX4o 

Lighting Control Multiplexer 

This page intentionally left blank 

Warning for Your Protection 

1. Read these instructions 

2. Keep these instructions 

3. Heed all warnings 

4. Follow all instructions 

5. Do not use this apparatus near water. 

6. Clean only with a dry cloth. 

7. Do not block any of the ventilation openings. Install in accordance with the manufacturer’s instructions. 

8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that  produce heat. 

9. Do not defeat the safety purpose of the polarized or grounding‐type plug. A polarized plug has two blades with one wider  than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are  provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the  obsolete outlet. 

10. Protect the power cord from being walked on or pinched, particularly at plugs, convenience receptacles, and the point  where they exit from the apparatus. 

11. Only use attachments/accessories specified by the manufacturer. 

12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with  the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid  injury from tip‐over.    

13. Unplug this apparatus during lightning storms or when unused for long periods of time. 

14. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been  damaged in any way, such as power‐supply cord or plug is damaged, liquid has been spilled or objects have fallen into the  apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped. 

The apparatus shall not be exposed to dripping or splashing. No objects filled with liquids, such as vases, shall be placed on the  apparatus. 

 “WARNING To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture.” 

General Installation Instructions 

Please consider besides these general instructions also any product‐specific instructions in the “Installation” chapter of this  manual. 

1

Registration 

Be sure to register your LightViper product, either by filling in the enclosed Registration Card or by completing the on‐line  registration form at our Web site: 

http://lightviper.com/register.aspx 

If you do so, FiberPlex can contact you with any update information. As enhancements and upgrades are developed, you will be  contacted at the registration address. Please read this manual ‐ if you call for technical support, we’ll assume that you have.  

Please address any inquiries to your dealer or directly to FiberPlex at: 

FiberPlex Inc. 

10840‐412 Guilford Rd. 

Annapolis Junction, MD 20701 

301.604.0100 Fax: 301.604.0773  [email protected] 

 

 

Warranty, Service and Terms and Conditions of Sale 

 

For information about Warranty or Service information, please see our published ‘Terms and Conditions of Sale’. This document  is available on  fiberplex.com   or can be obtained by requesting it from  [email protected]

 or calling 301.604.0100. 

2

Disposal 

Disposal of Packing Materials  

The packing materials have been selected with environmental and disposal issues in mind. All packing material can be recycled. 

Recycling packing saves raw materials and reduces the volume of waste. If you need to dispose of the transport packing  materials, please try to use recyclable means. 

Disposal of Used Equipment  

Used equipment contains valuable raw materials as well as materials that must be disposed of professionally. Please return  your used equipment via an authorized specialist dealer or via the public waste disposal system, ensuring any material that can  be recycled is. Please take care that your used equipment cannot be abused. After having disconnected your used equipment  from the mains supply, make sure that the mains connector and the mains cable are made useless. 

Declarations of Conformity 

Class A Equipment ‐ FCC Notice 

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC 

Rules. These limits are designed to provide a reasonable protection against harmful interference when the equipment is  operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not  installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. 

Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required  to correct the interference at his own expense. 

Disclaimer 

The information in this document has been carefully checked and is believed to be accurate at the time of publication. 

However, no responsibility is taken by us for inaccuracies, errors, or omissions, nor is any liability assumed for any loss or  damage resulting either directly or indirectly from use of the information contained within it.

  

3

Introduction 

Congratulations on your purchase of a LightViper system. LightViper products are designed, engineered and manufactured by 

FiberPlex Inc., experts in fiber optics with decades of experience. Our work in audio and data communications products is  known in US government applications worldwide.  LightViper products combine our pioneering technology with the highest  standards in audio engineering. 

The LightViper System 

You have purchased the LightViper DMX4. Instead of traditional heavy multi‐conductor copper cable, 

LightViper fiber optic systems utilize lightweight, flexible, military tactical grade fiber‐optic cable or  duplex PVC and plenum rated fiber for installation use. The DMX4i and DMX4o units allow you send 

(4) universes of DMX lighting control through your LightViper snake system (FOH to Stage only) via  the same fiber‐optic cable that carries your (8) audio returns. 

The Fiber Advantage 

 Fiber optics offer many advantages over copper: 

 Transmits light rather than electrons 

 Transmission over greater distances (more than 2 Km [1.25 mile]) 

 Complete electrical isolation 

 Immunity to RFI and EMI 

 Eliminates ground loop problems 

 Can be routed overhead, through walls, or underground 

 Avoids foot traffic while maintaining aesthetics 

Functional Considerations 

The Light Viper DMX4 is an accessory item intended for use with any LightViper 1832, 4832 or 1808 system. These units will  only work when properly connected to an existing LightViper fiber‐optic system. The LightViper DMX4 units contain no user  serviceable parts. Please contact Fiberplex directly with any service issues. 

Standard Components 

DMX4i — The DMX4i contains (4) 3‐pin female XLR connectors (inputs), (4) 5‐pin female XLR connectors (inputs), a single  female DB9 connector (inputs), and a single RJ45 EtherCon™ connector. All DMX control inputs are connected to this unit. 

DMX4o – The DMX4o contains (4) 3‐pin male XLR connectors (outputs), (4) 5‐pin male XLR connectors (outputs), a single male 

DB9 connector (output), and a single RJ45 EtherCon™ connector. All DMX control inputs are connected to this unit. 

DMX interface cables – DMX cables are required to input DMX control into the DMX4i and output DMX control from the 

DMX4o. These cables are not supplied with the DMX4 units and can be purchased separately from your local lighting or music  retailer. The DMX4i and DMX4o can use either (3) pin or (5) pin DMX cables. This system offers ONE WAY control only – from 

FOH to stage. 

CAT5 Jumpers – CAT5 jumpers are required to connect the DMX4i and DMX4o to the LightViper transport system. These  jumpers are not supplied with the DMX4 units. We recommend “Ruggedized” CAT5 connectors be used in situations where  these cables may be prone to being stepped on or pulled while in use.  

4

Getting Started 

To connect & use your DMX4 units please follow these steps: 

1. Place the DMX4i as near as possible to the VIM‐1832 mixer box or VIM‐MY32S cards. Connect the DMXi to your VIM‐

1832 mixer box or VIM‐MY32S cards using “ruggedized” CAT5 cable. 

2. Place the DMX4o unit on stage as near as possible to the lighting fixtures you will be controlling. Connect the DMXo to  your VIS‐1832 mixer box, VIS‐4832 or VIM‐0808 unit using “ruggedized” CAT5 cable. 

3. Connect the DMX control between the lighting controller and the DMX4i. 

4. Connect the DMX4o to the lighting fixtures being controlled. 

5. Test the system to ensure control is working 

DMX4i (Input)

1 2 3 4 5

1 2 3 4 5

DMX4o (Output)

Note: The DMX4i and DMX4o are identical with the exception that DMX is input to the DMX4i and output  from the DMX4o. 

With that in mind, the description below pertains to both units

. The DMX4o is identical  except the XLR and DB9 connectors are female as it is providing DMX output from the LightViper system. 

DMX4i/DMX4o 

1  (3) pin XLR connectors ‐ This is where the DMX control is input into DMX4i and output from the DMX4o. 

2  (5) pin XLR connectors ‐ This is alternatively where the DMX control is input into the DMX4i and output from the DMX4o. 

3  DB9 Connector – This is where the Yamaha control protocol can be input to the DMX4i and output from the DMX4o via a 9 pin  crossover cable. 

4  RJ45 EtherCon™ Connector – This connector provides the interface between the DMX4i and the VIM‐1832, VIM‐MY32S or VIM‐1808,  and between the DMX4o and the VIS‐1832, VIS‐4832 or VIM‐0808. 

5  Sync LED – This LED is unlit when no AC power is present and green when the unit is powered and in sync. Both the DMX4i and DMX4o  receive their power from the LightViper units they are connected to through this RJ45 connector. 

Important: Each channel has a selection of connectors. Only one connector per channel may be used at one  time. This includes the D9 HA control connector on channel 4. 

5

LightViper DMX4i / DMX4o Specifications 

1. General Specifications

Operating Temp

Sync LED

0 to +50°C ambient temperature.

LED (green) indicates the RJ45 link is OK, LED (red) indicates problem with RJ45 link, LED (off) indicates no power.

AC Power

Max Current Rating

Control

DMX Data

Dimensions

Weight

N/A

VIM-MY32M

RJ-45 connector for logic level control, CMOS or TTL at 2 MHz max per channel.

Single Direction, fully complies with the USITT DMX512 Specification

DMX4

DMX4

DMX Connector Pin Outs

3 Pin XLR (typ M/F)

1. Gnd

5 Pin XLR (typ M/F)

1. Gnd

3.5 W from RJ45 host unit

1 Rack Unit X 6.5" (165mm) Deep

9 lbs (4 Kg) Packed for shipment

4. N/C

5. N/C

HA Connector Pin Outs

1. Unused

5. Ground

7. Unused

8. Unused

9. Unused

Control Circuits RJ-45 Pin Outs

1. GND

2. TX1

3. TX2

4. TX3

5. RX1

6. RX2

7. RX3

6

This page intentionally left blank 

8

 

 

 

 

 

 

 

LVDXUM 8/2011 

18040-412 Guilford Rd. • Annapolis Junction, MD 20701 fiberplex.com • [email protected]

• 301.604.0100

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement