Carrier 48GP 024-060, 48GPN 024-060 Gas heating/electric cooling unit Installation, Start-Up, and Operating Instructions

Below you will find brief information for 48GP 024-060, 48GPN 024-060. This Carrier Gas heating/electric cooling unit combines gas heating and electric cooling capabilities in a single system, providing efficient climate control for your home. The units are designed for outdoor installation on various surfaces and offer a range of features, including a condensate drain, an accessible external manual shutoff valve, and a high-efficiency gas burner.

PDF Download
Document
Carrier 48GP 024-060, 48GPN 024-060 Installation Instructions | Manualzz

Advertisement

Advertisement

Advertisement

Key features

  • Gas heating and electric cooling
  • Outdoor installation
  • Condensate drain
  • External manual shutoff valve
  • High-efficiency gas burner

Frequently asked questions

The required minimum operating and service clearances are shown in Fig. 6 and 7. Adequate combustion, ventilation, and condenser air must be provided, in accordance with section 5.3, Air for Combustion and Ventilation, of the National Fuel Gas Code ANSI (American National Standards Institute) Z223.1 (in Canada, sections 7.2, 7.3 or 7.4 or Can/CGA [Canadian Gas Association] B149 Installation Codes), or applicable provisions of local building code.

48GPN units are dedicated Low NOx units designed for California installations. These models meet the California maximum oxides of nitrogen (NOx) emissions requirement of 40 nanograms/joule or less as shipped from the factory and MUST be installed in California Air Quality Management Districts where a Low NOx rule exists.

The 48GP units dispose of condensate water through a 3/4 in. NPT fitting which exits through the compressor access panel. See Fig. 6 and 7 for location. Condensate water can be drained directly onto the roof in rooftop installations (where permitted) or onto a gravel apron in ground-level installations. Install a field-supplied condensate trap at end of condensate connection to ensure proper drainage.

The venting system is designed to ensure proper venting. The flue hood assembly must be installed as indicated in this section of the unit installation instructions. Dedicated low NOx 48GP models MUST be installed in California Air Quality Management Districts where a Low NOx rule exists. These models meet the California maximum oxides of nitrogen (NOx) emissions requirement of 40 nanograms/joule or less as shipped from the factory.

The unit cabinet must have an uninterrupted, unbroken electrical ground to minimize the possibility of serious injury if an electrical fault should occur. This ground may consist of an electrical wire connected to the unit ground lug in the control compartment, or conduit approved for electrical ground when installed in accordance with NEC (National Electrical Code) ANSI/ NFPA 70 (latest edition) (in Canada, Canadian Electrical Code CSA [Canadian Standards Association] C22.1) and local electrical codes. Do not use gas piping as an electrical ground.