Hinkley 3105SL Five Light Linear Instruction manual
Hinkley 3105SL is a versatile lighting fixture that can be mounted in three different ways: flush mount, chain hung, or post-mount. It features a durable construction and a stylish design that will complement any décor. With its easy-to-follow instructions, the Hinkley 3105SL is a great choice for do-it-yourselfers.
Advertisement
Advertisement
DRAWING 1 - MOUNTING
A
1
2
E
4
5
3
9
8
5
10
chain ground wire
DRAWING 2 - MOUNTING
supply wire
HOOK INSPECTION
CABLE TO MOUNTING STRAP.
Mounting Instructions 3105
start here
English
1.
Shut off electrical current before starting. If the fixture you are replacing is turned on and off by a wall switch, simply turn the switch off. If not, remove the appropriate fuse (or open the circuit breakers) until the fixture is dead.
DO NOT restore current --- either by fuse, breaker or switch --- until the new fixture is completely wired and in place.
SAFETY WARNING: READ WIRING AND GROUNDING INSTRUCTIONS
(I.S. 18) AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF
DURING INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULT A
QUALIFIED ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE
REQUIREMENTS.
1.
Fasten mounting strap (1) to outlet box (A) with the original outlet box screws (2) --- see Drawing 1.
2.
Thread nipple (3) into mounting strap (1) approximately 3/8’’.
1.
Taking the chain, determine the length you require to hang the fixture.
2.
Attach one end of the chain to the top loop of the fixture.
3.
Attach other end of chain the loop (4) on canopy.
1.
Unwrap supply wire and ground wire and weave them up throuagh the chain.
2.
Slip supply wire and ground wire through center hole (E) of loop
(4).
Note: Get assistance for this step since fixture may be heavy and difficult to hold while attaching the chain.
3.
Connect ground wire to mounting strap (1) using green ground screw (5).
4.
Make electrical connections from supply wire to fixture lead wires. Refer to instruction sheet (I.S. 18) and follow all instructions to make all necessary wiring connections.
5.
Slip canopy (10) over nipple (3) and up against ceiling.
6.
Thread knurled knob (8) onto threaded tube (3) and tighten up against canopy. Then thread on ring nut (9) to complete mounting.
1. To mount fixture to ceiling, first attached mounting bracket (1) to junction box
(J) mounted in the ceiling - see DRAWING 2.
2. Next thread center threaded tube (3) into center hole in mounting bracket (1) approximately 1/2” (12.5mm).
3. Now with assistance take the assembled fixture and lift it up and using hook on end of inspection cable, hook it into the mounting strap.Now slowly release the fixture until it is safely hanging from the inspcetion cable.
4. Now make all necessary electrical connections follow instruction sheet (IS18) provided.
5. After all connection are made, tuck wires into junction box and lift fixture and slide threaded tube (3) through center hole in canopy and hold canopy in position.
6. Now thread knob (5) onto end of threaded tube (3) and tighten to secured fixture to ceiling.
Instrucciones De Montaje 3105
Spanish
empezar aquí
1.
Couper le courant électrique avant de commencer. Si l’appareil vous remplacez est activé et désactivé par un interrupteur mural, il suffit de tourner l’interrupteur. Sinon, retirez le fusible approprié (ou ouvrez les disjoncteurs) jusqu’á ce que l’appareil est mort.
NE PAS restaurer actuel --- soit par fusible, disjoncteur ou interrupteur
--- jusqu’á ce que le nouvel appareil estérement câblé et en place.
AVERTISSEMENT DE SECURITE: LIRE CABLAGE ET INSTRUCTIONS DE
MISE (IS 18), ET TOUTE AUTRE INSTRUCTION. COUPER L’ALIMENTATION
ELECTRIQUE PENDANT L’ONSTALLATION. SI DE NOUVELLES CABLAGE
N’EST NECESSAIRE, CONSULTEZ UN ELECTRICIEN QUALIFIE OU
AUTORITES LOCALES POUR EXIGENCES DU CODE..
1.
Fixer sangle de fixation (1) á la boîte de sortie (A) avec les vis de la boîte de sortie d’origine (2) --- Voir Schéma 1.
2.
Mamelon de filetage (3) en bande de montage (1) d’environ
9.525mm.
Instructions de montage 3105
French
commencez ici
1.
Apague la corriente eléctrica antes de comenzar. Si el aparato va a sustituir se enciende y se apaga por un interruptor de pared, simplemente gire el interruptor. Si no es así, quite el fusible adecuado (o abra los interruptores de circuito) hasta que el aparato esta muerto.
NO restaurar actual --- ya sea mediante fusible, disyuntor o interruptor --- hasta que el Nuevo dispositivo está completamente conectoado y en su lugar.
ADVERTENCIA DE SEGURIDAD: LEA LAS INSTRUCCIONES DE CABLEADO
Y LA TIERRA (IS 18), E INSTRUCCIONES ADICIONALES. APAUGE LA
ALIMENTACIÓN DE CORRIENTE DURANTE LA INSTALACIÓN. SI SE
REQUIERE NUEVO CABLEADO, CONSULTE CON UN ELECTRICISTA O
AUTHORIDADES LOCALES PARA REQUISITOS DEL CÓDIGO.
1.
Fije la correa de montaje (1) de ka caja de salida (A) con los tornillos de la caja de salida de originales (2) --- Véase la Figura 1
2.
Niple de rosca (3) en el soprte de montaje (1) de aproximadamente
9.525mm.
1.
Prenant la chaîne, determiner la longueur don’t vous avez besoin pour accrocher l’appareil.
2.
Fixez une extrémité de la chaîne á la boucle supérieure de l’appareil.
3.
Attacher autre extrémité de la chaíne de la boucle (4) sur la voilure.
1.
Tomando la cadena, determiner la longitude que usted necesita para colgar el aparato.
2.
Conecte un extremo de la cadena en la curva superior del aparato.
3.
Conecte el otro extremo de la cadena del lazo (4) en la campana.
1.
Déroulez cable d’alimentation et cable de terre et les tisser á travers la chaîne.
2.
Glissez fournir des fils et fil de terre á travers le trou central (E) de la boucle (4).
Note : obtenez de l’aide pour cette étape depuis luminaire peut être lourd et difficile á tenir tout en attachant la chaine.
3.
Connectez le fil de terre á la sangle de fixation (1) avec la vis de terre vete (5).
4.
Effectuez les connexions électriques du câble d’alimentation á fils de connexion du projecteur. Reportez-vous á la feuille d’instruction (I.S.
18) et suivez toutes les instructions pour effectuer tous les branchements nécessaires.
5.
Glissez verriére (10) sur mamelon (3) et contre le plafond.
6.
Enrosque el botón moleteado (8) en el tubo roscado (3) y apriételo contra el dosel. A continuación, enrosque la perilla decorativa (9) para completar montaje.
1. Para montar la luminaria al techo, primero sujete el soporte de montaje (1) a la caja de empalmes (J) montada en el techo - vea DIBUJO
2.
2. Luego, enrosque el tubo roscado central (3) en el orificio central del soporte de montaje (1) aproximadamente 1/2 "(12,5 mm).
3. Ahora con la ayuda tome el montaje fijado y levántelo para arriba y usando el gancho en el final del cable de la inspección, engancharlo en la correa de montaje. Ahora lentamente suelte el accesorio hasta que esté colgando con seguridad del cable de la inspección.
4. Ahora haga todas las conexiones eléctricas necesarias siguiendo la hoja de instrucciones (IS18) proporcionada.
5. Después de hacer todas las conexiones, enrosque los cables en la caja de empalmes y en el accesorio de elevación y deslice el tubo roscado (3) a través del orificio central en el dosel y mantenga la cubierta en posición.
6. Ahora enrosque la perilla (5) en el extremo del tubo roscado (3) y apriétela hasta el techo.
1.
Separa cable de alimentación y cable de tierra para tejer con ellos a través de la cadena.
2.
Deslice suministrar alambre y cable de tierra a través dek centro del agujero (E) del bucle (4).
Nota: Obtenga ayuda para este paso ya accesorio puede ser pesado y difícil de mantener mientras se coloca la cadena.
3.
Conecte el cable de tierra a la brida de montaje (1) con el tornillo verde de tierra (5).
4.
Haga las conexiones eléctricas de los cables de alimentación a los cables conductores accesorio. Consulte la hoja de instrucciones (I.S.
18) y siga las instrucciones para hacer todas las conexiones necesarias.
5.
Deslice dosel (10) sobre la boquilla (3) y hasta contra el techo.
6.
Enfiler le bouton moleté (8) sur le tube fileté (3) et le serrer contre le canopée. Ensuite, enfilez le bouton décoratif (9) pour terminer montage.
1. Pour monter le montage au plafond, le premier support de fixation (1) à la boîte de jonction (J) monté dans le plafond - voir DESSIN 2.
2. Suivre le fil fileté central (3) dans le trou central dans le support de montage (1) d'environ 1/2 "(12,5 mm).
3. Maintenant, avec assistance, prenez l'appareil assemblé et soulevez-le et utilisez le crochet à la fin du câble d'inspection, accrochez-le dans la sangle de montage. Souvenez-vous de relâcher lentement l'appareil jusqu'à ce qu'il soit bien suspendu au câble d'entrée.
4. Maintenez les connexions électriques nécessaires suivre la fiche d'instructions (IS18).
5. Une fois toutes les connexions effectuées, enfilez les fils dans la boîte de jonction et le dispositif de levage et faites glisser le tube fileté (3) à travers le trou central dans la canopée et maintenez la canopée en position.
6. Maintenant, tournez le bouton (5) sur l'extrémité du tube fileté (3) et serrez-le à la fixation fixée au plafond.
HINKLEY 33000 Pin Oak Parkway, Avon Lake, OH 44012 800.446.5539 / 440.653.5500 hinkley.com
Drawing 1 – Flush Mount
M
S
Drawing 2 – Chain Hung
M
S
Drawing 3 – Post-Mount
I.S. 18
wiring grounding instructions
SAFETY WARNING: READ WIRING AND GROUNDING
INSTRUCTIONS (IS 18) AND ANY ADDITIONAL DIRECTIONS.
TURN POWER SUPPLY OFF DURING INSTALLATION. IF NEW
WIRING IS REQUIRED, CONSULT A QUALIFIED ELECTRICIAN OR
LOCAL AUTHORITIES FOR CODE REQUIREMENTS
I.S. 18
câblage échouage instructions
AVERTISSEMENT DE SECURITE: LIRE CABLAGE ET INSTRUCTIONS DE
MISE (IS 18), ET TOUTE AUTRE INSTRUCTION. COUPER L’ALIMENTATION
ELECTRIQUE PENDANT L’ONSTALLATION. SI DE NOUVELLES CABLAGE
N’EST NECESSAIRE, CONSULTEZ UN ELECTRICIEN QUALIFIE OU
AUTORITES LOCALES POUR EXIGENCES DU CODE.
wiring instructions
Indoor Fixtures
1.
Connect positive supply wire (A) (typically black or the smooth, unmarked side of the two-conductor cord) to positive fixture lead (B) with appropriately sized twist on connector - see Drawings 1 or 2 .
2.
Connect negative supply wire (C) (typically white or the ribbed, marked side of the two-conductor cord) to negative fixture lead (D).
3.
Please refer to the grounding instructions below to complete all electrical connections
Outdoor Fixtures
1.
Connect positive supply wire (A) (typically black or the smooth unmarked side of the two-conductor cord) to positive fixture lead (B) with appropriately sized twist on connector --- see Drawings 2 or 3.
2.
Connect negative supply wire (C) (typically white or the ribbed, marked side of the two-conductor cord) to negative fixture lead (D).
3.
Cover open end of connectors with silicone sealant to form a watertight seal.
If installing a wall mount fixture, use caulk to seal gaps between the fixture mounting plate (backplate) and the wall. This will help prevent water from entering the outlet box. If the wall surface is lap siding, use caulk and a fixture mounting platform specially.
instructions de câblage
Luminaires Itérieurs
1.
Brancher le fil d’alimentation positive (A) (généralement noir ou, côté lisse banalisée de la corde á deux conducteurs) á plob de fixation positive (B) avec la torsion de taille appropriée sur le connecteur --- Voir Schéma 1 ou 2.
2.
Connecter le fil d’alimentation négative (C) (généralement blanc ou l’, côté marqué nervurée du fil á deux conducteurs) au conducteur négatif de l’appareil (D).
3.
S’il vous plaît se référer á la mise á la terre instructions ci-dessous pour terminer toutes les connexions électriques.
Luminaires Extérieurs
1.
Brancher le fil d’alimentation positive (A) (généralement noir ou le côté lisse banalisée de la corde á deux conducteurs) á plomb de fixation positive (B) avec la torsion approrpriately taille du connecteur --- Voir Schéma 2 ou 3.
2.
Connecter le fil d’alimentation négative (C) (généralement blanc ou l’, côté marqué nervurée du fil á deux conducteurs) au conducteur négatif de l’appareild (D).
3.
Couvrir extrémité ouverte de connecteurs acex du silicone pour former un joint étenche á l’eau.
Si l’installation d’un luminaire de montage mural, utiliser calfeutrage pour sceller l’espace entre la plaque de montage de fixation (plaque arriére) et la paroi. Cela aidera á empêcher l’eau de pénétrer dans le boc sortie. Si la surface du mur est bardage á clin, utiliser caldeutrage et une plate-forme de montage d’appareils spécialement.
4.
S’il vous plait se referrer auc instructions ci-dessous pour terminer la terre toutes les connexions électrques.
4.
Please refer to the grounding instructions below to complete all electrical connections.
grounding instructions
Flush Mount Fixtures
For positive grounding in a 3-wire electrical system, fasten the fixture ground wire (E) (typically copper or green plastic coated) to the fixture mounting strap (M) with the ground screw (S) - see Drawing 1 .
Note: On straps for screw supported fixtures, first install the two mounting screws in strap. Any remaining tapped hole may be used for the ground screw .
Chain Hung Fixtures
Loop fixture ground wire (E) (typically copper or green plastic coated) under the head of the ground screw (S) on fixture mounting strap (M) and connect to the loose end of the fixture ground wire directly to the ground wire of the building system with appropriately sized twist-on connectors - see Drawing 2 .
Post-Mount Fixtures
Connect fixture ground wire (E) (typically copper or green plastic coated) to power supply ground with appropriately sized twist-on connector inside post. Cover open end of connector with silicone sealant to form a watertight seal - see Drawing 3 .
instructions de mise
Montage Encastré Fixtures
Pour la terre positive dans un systéme électrique á 3 fils, fixez le fil de terre du luminaire (E) (généralement en cuivre ou vert recouvert de plastique) á la sangle de fixation de fixation (M) avec la vis de terre (S) --- Voir Schéma 1.
Remarque: Sur les sangles pour les appareils pris en charge á vis, installez d’abord les deux vis de fixation á sangle. Tout trou taraudé restante peut être utilisée pour la vis de terre.
Chaîne Accroché Luminaires
Boucle fil du luminaire au sol (E) (généralement en cuivre ou vert recouvert de plastique) sous la tête de la vis de terre (S) sur la sangle de fixation de fixation
(M) et se connecter á l’extrémitré libre du fil de terre du luminaire directement sur le fil de terre du systéme de construction avec une taille appropriée connecteurs á visser --- Voir Schéma 2.
Luminaires Aprés Montage
Brancher le fil de terre du luminaire (E) (généralement en cuivre ou vert recouvert de plastique) á la masse de l’alimentation avec une taille appropriée torsion sur le connecteur á l’intérieur de la poste. Couvrir extrémité ouverte du connecteur avec du mastic silicone pour former un joint étache á l’eau --- Voir
Schéma 3.
HINKLEY 33000 Pin Oak Parkway, Avon Lake, OH 44012 800.446.5539 / 440.653.5500 hinkley.com
I.S. 18
tierra cableado instrucciones
ADVERTENCIA DE SEGURIDAD: LEA LAS INSTRUCCIONES DE CABLEADO
Y LA TIERRA (IS 18), E INSTRUCCIONES ADICIONALES. APAUGE LA
ALIMENTACIÓN DE CORRIENTE DURANTE LA INSTALACIÓN. SI SE
REQUIERE NUEVO CABLEADO, CONSULTE CON UN ELECTRICISTA O
AUTHORIDADES LOCALES PARA REQUISITOS DEL CÓDIGO
Instrucciones de cableado
Acesorios Cubierta
1.
Conecte el cable de alimentación positive (A) (normalmente negro o la cara lisa, sin marcas del cable de dos conductores) de plomo accesorio positivo (B) con un giro de tamaño adecuado en el conector --- Véase la Figura 1 y 2.
2.
Conecte el cable de alimentación negativa (C) (por lo general de color blanco o el lado marcado estriado del cable de dos conductores) de plomo accesorio negativo (D).
3.
Por favor, consulte las instrucciones de puesta a tierra-a continuación para completar todas las conexiones eléctricas.
Accesorios Exterior
1.
Conecte el cable de alimentación positiva (A) (normalmente negro el lado no marcado suave del cable de dos conductores) de plomo accesorio positivo (B) con un giro de tamaño approrpriately conector --- Véase la Figura 2 y 3.
2.
Conecte el cable de alimentación negative (C) (por lo general de color blanco o el lado marcado estriado del cable de dos conductores) de plomo accesorio negativo (D).
3.
Cubra el extreme abierto de conectores con sellador de silicona poara formar un sello hermético.
Si va a instalar un soporte de fijación mural, use masilla para sella los espacios entre la placa de montaje del aparato (placa) y la pared. Esto ayudará a evitar que el agua entre en la boc salida. Si la superficie de la pared es de revestimiento solapado, utilice masilla y una plataforma de montaje accesorio especial.
4.
Por favor, consulte las Instrucciones de puesta a tierra-a continuación para completar todas las conexiones eléctricas.
instrucciones puesta a tierra
Montaje Embutido Accesorios
Para conectar a tierra en un sistema eléctrico de 3 hilos, fije el cable de tierra del artefacto (E) (generalmente de cobre o verde recubierto de plástico) a la brida de montaje accesorio (M) con el tornillo de tierra (S) --- Véase la Figura 1.
Nota : En las correas de accesorios compatibles tornillos, primero instale los dos tornillos de montaje de la correa. Cualquier agujero roscado restante puede ser utilizado para el tornillo de tierra.
Cadena Hung Accesorios
Loop alambre de tierra (E) (generalmente de cobre o verde recubierto de plático) debajo de la cabeza del tornillo de tierra (S) en la brida de montaje accesorio (M) y conectar con el extremo suelto del cable de tierra luminaria directamente al cable de tierra del sistema de construcción con un tamaño adecuado twist-conectores --- Véase la Figura 2.
Accesorios Posterior Monte
Conecte el cable de tierra del artefacto (E) (generalmente de cobre o verde recubierto de plástico) a tierra de la fuente de alimentacón con conector de tamanño adecuado en el interior puesto enlaces en forma. Cubra el extremo abierto del conector con sellador de silicona para formar un sello hermético ---
Véase la Figura 3.

Public link updated
The public link to your chat has been updated.
Advertisement
Key features
- - Can be mounted in three different ways: flush mount, chain hung, or post-mount
- - Durable construction
- - Stylish design
- - Easy-to-follow instructions