assembly instructions

Family: Plantation Item No. 4886 CB/BB/PL

Drawing 1 - Fixture Assembly

2

B

A

1

3

5

4

C

7

Drawing 2 - Glass Installation

6

E

10

9

D

8

start here

1.

Find a clear area in which you can work.

2.

Unpack fixture and glass from carton.

3.

Carefully review instructions prior to assembly.

3

*** The construction of this fixture will be accomplished by first assembling the main body of the fixture, making all necessary electrical connections, hanging the fixture from the ceiling, and then installing the fixture glass.

SAFETY WARNING: READ WIRING AND GROUNDING INSTRUCTIONS (I.S. 18)

AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING

INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULT A QUALIFIED

ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS.

1.

Slip top crown (2) along wire and thread into top of main body assembly (1) - see

Drawing 1 .

2.

Spread arms (A) of the fixture until they are equally spaced apart and located in between the uprights (B) .

3.

Please refer to the hanging instruction sheet (I.S. 19) provided to hang fixture. Then refer back to this sheet to continue installation of this fixture.

1.

Slip candle sleeve (4) over socket (C) - see Drawing 2 .

2.

Slip harp (5) onto top of candle sleeve (4) .

3.

Attach shade (6) on the top of harp (5) .

4. Thread finial (7) into top of harp (5) to secure shade (6) .

5.

To assemble center glass (8) , take top crown assembly (9) and thread into coupler (D) .

6.

Attach center glass (8) to center bobesche (E) by threading in stud screws (10) .

Note: DO NOT use tools to tighten stud screws (10) . Over tightening may cause glass damage.

2.7.08

REVISION 1

H I N K L E Y L I G H T I N G 33000 Pin Oak Parkway Avon Lake, OH 44012 800.446.5539 / 440.653.5500 hinkleylighting.com

Drawing 1 - Hanging Assembly

A

1

B

2

3b

3a

4

5

GS

3c

6

C weave supply wire and ground wire through chain

Drawing 2 - Canopy Adjustment

half of threaded area exposed

I.S.19

hanging instructions

star t here

SAFETY WARNING: READ WIRING AND GROUNDING INSTRUCTIONS (I.S. 18)

AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING

INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULT A QUALIFIED

ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS.

1.

Shut off electrical current before starting. If the fixture you are replacing is turned on and off by a wall switch, simply turn the switch off. If not, remove the appropriate fuse (or open the circut breakers) until the fixture is dead.

• DO NOT restore current - either by fuse, breaker or switch - until the new fixture is completely wired and in place.

1 . Fasten mounting strap (1) to outlet box (A) with the two 8-32 screws (NOT PROVIDED)

(2) -see Drawing 1.

2.

Thread 2 - hex nuts (3a) and (3b) onto threaded tubing (4) .

3 . Thread one end of threaded tubing (4) into loop (5) a minimum of 1/2” to 3/4”.

Thighten hexnut (3a) against loop (5) to lock loop in position.

4 . Thread other end of threaded tube (4) into mounting strap approximately 1/2”.

5 . Slip canopy (B) over loop (5) and adjust height of loop so half of the threaded area

on the loop is exposed - see Drawing 2 below. After loop height is adjusted, thigten

hex nut (3b) up against mounting strap, tighten against mounting strap to lock

in position.

6 . Remove mounting strap (1) from junction box (A) , and thread third hex nut (3c) onto

end of threaded tube (4) above the mounting strap, tighten against mounting strap

to lock assembly in position.

7 . Remount mounting strap to junction box.

1.

Taking the chain, determine the length you require to hang the fixture.

2.

Attach one end of the chain to the top loop of the fixture.

3.

Now slip loop collar (6) and canopy (B) onto chain - see DRAWING 2.

4.

Attach other end of chain to loop (5) . Get assistance for this step since fixture may be heavy and difficult to hold while attaching the chain.

1.

Unwrap supply wire and ground wire and weave them up through the chain.

2.

Slip supply wire and ground wire through center of loop (5) .

3.

Connect ground wire to mounting strap (1) using green ground screw (GS) .

4.

Make electrical connections from supply wire to fixture lead wires. Refer to instruction sheet (I.S. 18) and follow all instructions to make all necessary wiring connections.

5.

Slip canopy up firmly against the ceiling and secure by turning the threaded collar (6) on loop (5) until tight.

H I N K L E Y L I G H T I N G 33000 Pin Oak Parkway Avon Lake, OH 44012 800.446.5539 / 440.653.5500 hinkleylighting.com

I.S. 18

wiring grounding instructions

Drawing 1 - Flush Mount

supply wire

C E

1

B D fixture leads twist-on connectors

2

Drawing 2 - Chain Hung

supply wire

A C

EE twist-on connectors

1

B D fixture leads

EE 2

Drawing 3 - Post-Mount

supply wire

A C

E twist-on connectors

E

B D fixture leads

SAFETY WARNING: READ WIRING AND GROUNDING INSTRUCTIONS (I.S. 18)

AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING

INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULT A QUALIFIED

ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS.

wiring instructions

Indoor Fixtures

1. Connect positive supply wire (A) (typically black or the smooth, unmarked side of the two-conductor cord) to positive fixture lead (B) with appropriately sized twist on connector - see Drawings 1 or 2 .

2. Connect negative supply wire (C) (typically white or the ribbed, marked side of the two-conductor cord) to negative fixture lead (D) .

3. Please refer to the grounding instructions below to complete all electrical connections.

Outdoor Fixtures

1. Connect positive supply wire (A) (typically black or the smooth unmarked side of the two-conductor cord) to positive fixture lead (B) with appropriately sized twist on connector - see Drawings 2 or 3 .

2. Connect negative supply wire (C) (typically white or the ribbed, marked side of the two-conductor cord) to negative fixture lead (D) .

3. Cover open end of connectors with silicone sealant to form a watertight seal.

• If installing a wall mount fixture, use caulk to seal gaps between the fixture mounting plate (backplate) and the wall. This will help prevent water from entering the outlet box. If the wall surface is lap siding, use caulk and a fixture mounting platform specially.

4. Please refer to the grounding instructions below to complete all electrical connections.

grounding instructions

Flush Mount Fixtures

For positive grounding in a 3-wire electrical system, fasten the fixture ground wire (E) (typically copper or green plastic coated) to the fixture mounting strap (1) with the ground screw (2) - see Drawing 1 .

Note: On straps for screw supported fixtures, first install the two mounting screws in strap.

Any remaining tapped hole may be used for the ground screw .

Chain Hung Fixtures

Loop fixture ground wire (E) (typically copper or green plastic coated) under the head of the ground screw (2) on fixture mounting strap (1) and connect to the loose end of the fixture ground wire directly to the ground wire of the building system with appropriately sized twist-on connectors - see Drawing 2 .

Post-Mount Fixtures

Connect fixture ground wire (E) (typically copper or green plastic coated) to power supply ground with appropriately sized twist-on connector inside post. Cover open end of connector with silicone sealant to form a watertight seal - see Drawing 3 .

H I N K L E Y L I G H T I N G 33000 Pin Oak Parkway Avon Lake, OH 44012 800.446.5539 / 440.653.5500 hinkleylighting.com