Family: Clifton Park Item No. 2424

Drawing 1 - Strap Detail

B gull wing bracket (side view)

Drawing 2 - Fixture Mounting

B

Drawing 3 - Fixture Assembly

1

2

5

start here

1.

Find a clear area in which you can work.

2.

Unpack fixture and glass from carton.

3.

Carefully review instructions prior to assembly.

*** The construction of this fixture will be accomplished by first installing the mounting strap to the junction box, making all necessary electrical connections, mounting the fixture to the wall.

1. Prepare mounting strap (A) by threading the two long mounting screws (B) into the back of the gull wing bracket - see Drawing 1 .

• Be sure the holes into which the screws are threaded match the spacing of holes (D) in the back plate (E) - see Drawings 1 and 2 .

2. Attach mounting strap (A) to junction box (J) using two 1” screws (C) not provided - see

SAFETY WARNING: READ WIRING AND GROUNDING INSTRUCTIONS (I.S. 18)

AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING

INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULT A QUALIFIED

ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS.

Make electrical connections from supply wire to fixture lead wires. Refer to instruction sheet (I.S. 18) and follow all instructions to make all necessary wiring connections. Then refer back to this sheet to continue installation of this fixture.

1. This fixture is manufactured with a safety cable. Refer to instruction sheet (I.S. 101)

provided then refer back to this sheet to continue installation of this fixture.

2. To mount fixture, slide backplate (E) over screws (B) and secure with ball knobs (F) - see Drawing 2 .

1.

Candle sleeves (1) must be placed over socket (2) prior to installing the bulb - see

Drawing 3 .

2.

Fixture can now be lamped accordingly.

6.11.08

H I N K L E Y L I G H T I N G 33000 Pin Oak Parkway Avon Lake, OH 44012 800.446.5539 / 440.653.5500 hinkleylighting.com

REVISION 1

I.S. 18

wiring grounding instructions

Drawing 1 - Flush Mount supply wire

C E

1

B D fixture leads twist-on connectors

2

Drawing 2 - Chain Hung supply wire

A C

EE twist-on connectors

1

B D fixture leads

EE 2

Drawing 3 - Post-Mount supply wire

A C

E twist-on connectors

E

B D fixture leads

SAFETY WARNING: READ WIRING AND GROUNDING INSTRUCTIONS (I.S. 18)

AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING

INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULT A QUALIFIED

ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS.

wiring instructions

Indoor Fixtures

1. Connect positive supply wire (A) (typically black or the smooth, unmarked side of the two-conductor cord) to positive fixture lead (B) with appropriately sized twist on connector - see Drawings 1 or 2 .

2. Connect negative supply wire (C) (typically white or the ribbed, marked side of the two-conductor cord) to negative fixture lead (D) .

3. Please refer to the grounding instructions below to complete all electrical connections.

Outdoor Fixtures

1. Connect positive supply wire (A) (typically black or the smooth unmarked side of the two-conductor cord) to positive fixture lead (B) with appropriately sized twist on connector - see Drawings 2 or 3 .

2. Connect negative supply wire (C) (typically white or the ribbed, marked side of the two-conductor cord) to negative fixture lead (D) .

3. Cover open end of connectors with silicone sealant to form a watertight seal.

• If installing a wall mount fixture, use caulk to seal gaps between the fixture mounting plate (backplate) and the wall. This will help prevent water from entering the outlet box. If the wall surface is lap siding, use caulk and a fixture mounting platform specially.

4. Please refer to the grounding instructions below to complete all electrical connections.

grounding instructions

Flush Mount Fixtures

For positive grounding in a 3-wire electrical system, fasten the fixture ground wire (E) (typically copper or green plastic coated) to the fixture mounting strap (1) with the ground screw (2) - see Drawing 1 .

Note: On straps for screw supported fixtures, first install the two mounting screws in strap.

Any remaining tapped hole may be used for the ground screw .

Chain Hung Fixtures

Loop fixture ground wire (E) (typically copper or green plastic coated) under the head of the ground screw (2) on fixture mounting strap (1) and connect to the loose end of the fixture ground wire directly to the ground wire of the building system with appropriately sized twist-on connectors - see Drawing 2 .

Post-Mount Fixtures

Connect fixture ground wire (E) (typically copper or green plastic coated) to power supply ground with appropriately sized twist-on connector inside post. Cover open end of connector with silicone sealant to form a watertight seal - see Drawing 3 .

H I N K L E Y L I G H T I N G 33000 Pin Oak Parkway Avon Lake, OH 44012 800.446.5539 / 440.653.5500 hinkleylighting.com

I.S.200

caulking instructions

start here

1. After securing fixture to the wall it is recommended that the gap between the wall

and fixture backplate be sealed with any good quality waterproof caulk or silicone sealant.

(NOT INCLUDED) See Drawing 1.

Drawing 1 bead of caulk to seal gap caulking gun

Backplate

1. After securing fixture in place it is recommended that the gap between the mounting top

and fixture base be sealed with any good quality waterproof caulk or silicone sealant.

(NOT INCLUDED). It is also recommended that a small bead of caulk or sealant be put under the ball knobs used to mount fixture.

See Drawing 2.