OPERATING­INSTRUCTIONS­AND­OWNERS­MANUAL

GAS FIRED INFRA-RED

TANK TOP HEATER

Model­#

MH540T

READ INSTRUCTIONS CAREFULLY: ­Read­and­follow­all­instructions.­Place­instructions­in­a­safe­ place­for­future­reference.­Do­not­allow­anyone­who­has­not­read­these­instructions­to­assemble,­ light,­adjust­or­operate­the­heater.

CYLINDER NOT INCLUDED

LANGUAGES INCLUDED:

•ENGLISH

•FRENCH

WARNING:

If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

­—­ Do­not­store­or­use­gasoline­or­other­flammable­vapors­and­liquids­in­the­vicinity­of­this­or­any­ other­appliance.

—­ An­LP­cylinder­not­connected­for­use­shall­not­be­stored­in­the­vicinity­of­this­or­any­other­ appliance.

—­ WHAT­TO­DO­IF­YOU­SMELL­GAS

­ •­ Do­not­try­to­light­appliance.

­ •­ Extinguish­any­open­flame.

­ •­ Shut­off­gas­to­appliance.

—­ DO­NOT­LEAVE­HEATER­UNATTENDED­OR­IN­OPERATION­WHILE­SLEEPING

This­is­an­unvented­gas-fired­portable­heater.­It­uses­air­(oxygen)­from­the­area­in­which­it­is­used.­

Adequate­combustion­and­ventilation­air­must­be­provided.­

42652 www.mrheater.com

800-251-0001

WARNING:

YOUR­SAFETY­IS­IMPORTANT­TO­YOU­

AND­TO­OTHERS,­SO­PLEASE­READ­THESE­INSTRUCTIONS­

BEFORE­YOU­OPERATE­THIS­HEATER.

GENERAL HAZARD WARNING:

FAILURE­TO­

COMPLY­WITH­THE­PRECAUTIONS­AND­INSTRUCTIONS­

PROVIDED­WITH­THIS­HEATER,­CAN­RESULT­IN­DEATH,­

SERIOUS­BODILY­INJURY­AND­PROPERTY­LOSS­OR­

DAMAGE­FROM­HAZARDS­OF­FIRE,­EXPLOSION,­BURN,­

ASPHYXIATION,­CARBON­MONOXIDE­POISONING,­AND/

OR­ELECTRICAL­SHOCK.­ONLY­PERSONS­WHO­CAN­

UNDERSTAND­AND­FOLLOW­THE­INSTRUCTIONS­SHOULD­

USE­OR­SERVICE­THIS­HEATER.­IF­YOU­NEED­ASSISTANCE­

OR­HEATER­INFORMATION­SUCH­AS­AN­INSTRUCTIONS­

MANUAL,­LABELS,­ETC.­CONTACT­THE­MANUFACTURER.­

SO­PLEASE­READ­THESE­INSTRUCTIONS­BEFORE­YOU­

OPERATE­THIS­HEATER.

WARNING:

FUELS­USED­IN­LIQUEFIED­PROPANE­GAS­

APPLIANCES,­AND­THE­PRODUCTS­OF­COMBUSTION­

OF­SUCH­FUEL,­CAN­EXPOSE­YOU­TO­CHEMICALS­

INCLUDING­BENZENE,­WHICH­IS­KNOWN­TO­THE­STATE­

OF­CALIFORNIA­TO­CAUSE­CANCER­AND­CAUSE­BIRTH­

DEFECTS­OR­OTHER­REPRODUCTIVE­HARM,­FOR­MORE­

INFORMATION­GO­TO­­WWW.P65WARNINGS.CA.GOV.

WARNING:

NOT­FOR­HOME­OR­RECREATIONAL­

VEHICLE­USE.

WARNING:

FIRE,­BURN,­INHALATION,­AND­

EXPLOSION­HAZARD.­KEEP­SOLID­COMBUSTIBLES,­SUCH­

AS­BUILDING­MATERIALS,­PAPER­OR­CARDBOARD,­

A­SAFE­DISTANCE­AWAY­FROM­THE­HEATER­AS­

RECOMMENDED­BY­THE­INSTRUCTIONS.­NEVER­USE­

THE­HEATER­IN­SPACES­WHICH­DO­OR­MAY­CONTAIN­

VOLATILE­OR­AIRBORNE­COMBUSTIBLES,­OR­PRODUCTS­

SUCH­AS­GASOLINE,­SOLVENTS,­PAINT­THINNER,­DUST­

PARTICLES­OR­UNKNOWN­CHEMICALS.

WARNING:

THIS­PRODUCT­CAN­EXPOSE­YOU­TO­

CHEMICALS­INCLUDING­LEAD­AND­LEAD­COMPOUNDS,­

WHICH­ARE­KNOWN­TO­THE­STATE­OF­CALIFORNIA­

TO­CAUSE­CANCER­AND­BIRTH­DEFECTS­OR­OTHER­

REPRODUCTIVE­HARM.­FOR­MORE­INFORMATION­VISIT­

WWW.P65WARNINGS.CA.GOV.

WARNING:

CARBON­MONOXIDE­CAN­KILL­YOU­

USING­A­PORTABLE­GAS­CAMPING­HEATER­INSIDE­

A­TENT,­RV,­CAMPER,­VEHICLE,­SHELTER,­OR­OTHER­

ENCLOSED­AREAS­CAN­PRODUCE­DEADLY­CARBON­

MONOXIDE.

CONTENTS

WARNINGS­..................................................................................

2

SPECIFICATIONS­..........................................................................

2

ASSEMBLY­AND­HOOKUP­INFORMATION­....................................

3

VENTILATION...............................................................................

3

MINIMUM­CLEARANCE­FROM­COMBUSTIBLE­MATERIALS­..........

4

ODOR­FADE­WARNING­................................................................

4

SAFETY­PRECAUTIONS­.................................................................

5

LIGHTING­INSTRUCTIONS­............................................................

6

SHUTDOWN­AND­STORAGE­INSTRUCTIONS­................................

6

PARTS­LIST­...................................................................................

7

WARRANTY­...............................................................................10

INSTRUCTIONS­FOR­ORDERING­PARTS­.......................................10

The heater is designed and approved for use as a construction heater and in accordance with ANSI Z83.7-

CSA 2.14. Check with your local fire safety authority if you have any questions about applications.

Other standards govern the use of fuel gases and heatproducing products and specific applications. Your local authority can advise you about these standards.

Mr. Heater |540T Gas-Fired Infra-Red Tank Top Heater

SPECIFICATIONS

A.

­­The­MH540T­is­a­high­pressure­propane­appliance­and­is­ designed­to­be­connected­to­a­bulk­propane­tank.­

B .­­This­heater­is­for­temporary­heating­of­buildings­under­ construction,­alterations,­or­repair.

C.

­­This­heater­is­equipped­with­an­automatic­Safety­Shutoff­

Valve.­The­gas­flow­will­automatically­stop­if­the­heater­fails­to­ operate­for­any­reason.­

D.

­­Maximum­safety­and­convenience­have­been­built­into­the­Hi-

Med-Lo-Off­Control­Valve/Regulator.­The­following­table­lists­ the­approximate­BTU’s­consumed­and­the­operating­hours­ you­can­reasonably­expect­from­bulk­propane­cylinders.­

SETTINGS BTU OUTPUT OPERATING TIME

LOW 30,000 14­HOURS

MEDIUM

HIGH

36,000 12­HOURS

45,000 9.5­HOURS

**OPERATING TIME USING 20LB LP TANK CYLINDER**

MIN Supply Pressure:

20­PSI­(138kPa)

Manifold Pressure

MAX.-­17­PSI­(117kPa)

Max Supply Pressure:

Tank­pressure

MIN.­-­9­PSI­(62kPa)

•Minimum­Ambient­Temp­=­20°F­(-6.7°C)

•Net­weight­of­unit:­(5.5lbs­/2.5kg)

2 Operating Instructions and Owner’s Manual

ASSEMBLY AND HOOK-UP INFORMATION

1.

­ Heater­model­MH540T­is­packaged­complete.­Propane­ cylinders­(tanks)­are­not­included­with­heater­model.­

2.

­ Remove­heater­from­carton.­

3.

­ This­heater­must­be­used­only­with­a­vapor­withdrawal­

LP­gas­bulk­tank­equipped­with­a­standard­POL­valve­

–­do­not­use­this­heater­on­bulk­tanks­greater­than­20­ pounds­LPG­capacity­(50­pounds­water­capacity).

4. Attach­Tank­collar(Figure­1.)

•­ The­tank­collar­bracket­must­be­assembled­before­ the­heater­can­be­attached­to­the­propane­tank.

•­ Align­screw­holes­on­tank­collar­bracket­with­the­ screw­holes­in­center­plate­such­that­the­heater­is­ facing­upward­once­attached­to­cylinder­collar.

•­ Screw­the­tank­collar­pieces­together­using­the­(3)­ packaged­screws.­

•­ Make­sure­the­tank­collar­bracket­is­firmly­secure­ to­heater­then­slide­the­bracket­to­the­propane­ tank­collar.­Once­in­place­secure­the­heater­to­the­ propane­tank­collar­by­turning­knob­clockwise­until­ it­is­firmly­hand­tighten.­

5.

­ ­­Make­sure­heater­regulator­is­in­the­“OFF”­position.­

Insert­hose­connector­into­tank’s­valve­and­turn­knob­

(counter­clock-wise)­firmly­hand­tighten.­Do­not­ overtighten.­(Figure­2)

6.

­ Operate­only­on­a­stable,­level­surface.­

7.

­ Open­propane­tank­valve­slowly.

8.

­ Check­all­fittings­for­leaks.­Apply­a­50/50­mixture­of­ liquid­soap­and­water­to­all­joints.­Bubbles­forming­ indicate­a­leaking­connection.­Correct­all­leaks­before­ proceeding.

WARNING

­ Never­touch­heater­while­in­operation­to­avoid­injury.­

Move­heater­by­grasping­the­propane­cylinder­carefully.­

SCREW

­HOLES

1 SCREW­HOLES

2

REGULATOR­CONTROL­

KNOB­

Figure­2

HOSE­CONNECTOR­KNOB­

9.

­­ The­heater­should­be­inspected­before­each­use­and­at­ least­annually­by­a­qualified­service­person.

10.

­The­hose­assembly­shall­be­visually­inspected­prior­to­ use­of­heater.­­If­it­is­evident­there­is­excessive­abrasion­ wear,­or­the­hose­is­sliced,­it­must­be­replaced­prior­to­ the­heater­being­put­into­operation.­Replacement­hose­ assembly­shall­be­Mr.­Heater­hose­assembly­as­listed­in­ the­parts­list.

VENTILATION

A. WARNING: This heater is an unvented appliance and

MUST be used ONLY in a well ventilated area. NEVER attempt­to­operate­the­heater­inside­any­vehicle,­camper­or­ enclosure.­

B.

FOR NON-RESIDENTIAL INDOOR AND OUTDOOR USE.

Any­combustion­process­requires­and­consumes­oxygen,­and­ will­produce­carbon­monoxide.­ THIS HEATER MUST BE

USED WITH ADEQUATE VENTILATION.

­Do­not­use­inside­ a­house,­camper,­tent­or­any­type­of­unvented­or­a­tightly­ enclosed­area.

C. WARNING: ­Provide­ample­ventilation.­This­heater­consumes­ air­(oxygen).­To­avoid­endangering­your­life­DO­NOT­use­this­ heater­in­unventilated­structures.­Provide­additional­ventilation­ for­any­additional­fuel-burning­appliances­and­additional­ occupants.­

D.

­Flow­of­combustion­and­ventilation­air­must­not­be­obstructed.

ALIGN­SCREW­

HOLES­SECTION­

1­ON­TO­2­

3­SCREWS

•­Turn­knob­clockwise­firmly­ hand­tighten­­to­tank­collar

Figure­1­

Mr. Heater |540T Gas-Fired Infra-Red Tank Top Heater 3 Operating Instructions and Owner’s Manual

MINIMUM CLEARANCE FROM

COMBUSTIBLE MATERIALS

A .­­When­operating,­the­heater­surfaces­are­extremely­hot.­Keep­ sleeping­bags,­clothing,­and­all­combustible­materials­clear­of­ the­heater­by­at­least­the­distances­shown­in­figure­3.­

B. WARNING: ­To­avoid­injury­or­property­damage­never­allow­ clothing,­tents­or­other­combustible­materials­within­36”­of­ the­face­of­the­heater.­This­heater­must­be­located­at­least­

27”­above­the­floor­level­when­in­use.­Never­operate­the­ heater­when­sleeping.­

C. WARNING: ­Never­direct­the­heat­output­of­this­heater­ toward­any­propane­tank­within­20­feet.­

36

48 ”

36 ”

27 ”

BTU/HR.­Rating

Model­ no.

BTU­

Input

CLEARANCE­TO­COMBUSTIBLES

FRONT SIDES REAR TOP

MH540T

30,000-

36,000-

45,000

36” 36” 36”

Figure­3­

ODOR FADE WARNING

48”

BELOW

27”

WARNING

Asphyxiation Hazard

•­ Do­not­use­this­heater­for­heating­human­living­­ quarters.

•­ Do­not­use­in­unventilated­areas.

•­ The­flow­of­combustion­and­ventilation­air­must­­ ­ not­be­obstructed.

•­ Proper­ventilation­air­must­be­provided­to­­ ­ ­

­ support­the­combustion­air­requirements­of­the­­ ­ heater­being­used.

•­ Refer­to­the­specification­section­of­the­heater’s­­ ­ manual,­heater­data­plate,­or­contact­the­factory­­ ­ to­­determine­combustion­air­ventilation­­ ­ ­ requirements­of­the­heater.

•­ Lack­of­proper­ventilation­air­will­lead­to­­ ­ improper­combustion.

•­ Improper­combustion­can­lead­to­carbon­­ ­ monoxide­poisoning­leading­to­serious­injury­or­­

­

­

­ death.­Symptoms­of­carbon­monoxide­poisoning­­ ­ can­include­headaches,­dizziness­and­difficulty­­ ­ in­breathing.

Mr. Heater |540T Gas-Fired Infra-Red Tank Top Heater

FUEL GAS ODOR

LP gas and natural gas have man-made odorants added specifically for detection of fuel gas leaks.

If a gas leak occurs you should be able to smell the fuel gas. Since Propane (LP) is heavier than air you should smell for the gas odor low to the floor. ANY GAS ODOR IS YOUR

SIGNAL TO GO INTO IMMEDIATE ACTION!

­ •­Do­not­take­any­action­that­could­ignite­the­fuel­gas.­Do­not­ operate­any­electrical­switches.­Do­not­pull­any­power­supply­ or­extension­cords.­Do­not­light­matches­or­any­other­source­ of­flame.­Do­not­use­your­telephone.

­ •­Get­everyone­out­of­the­building­and­away­from­the­area­ immediately.

­ •­Close­all­propane­(LP)­gas­tank­or­cylinder­fuel­supply­valves,­ or­the­main­fuel­supply­valve­located­at­the­meter­if­you­use­ natural­gas.

­ •­Propane­(LP)­gas­is­heavier­than­air­and­may­settle­in­low­ areas.­When­you­have­reason­to­suspect­a­propane­leak,­keep­ out­of­all­low­areas.

­ •­Use­your­neighbor’s­phone­and­call­your­fuel­gas­supplier­and­ your­fire­department.­Do­not­re-enter­the­building­or­area.

­ •­Stay­out­of­the­building­and­away­from­the­area­until­declared­ safe­by­the­firefighters­and­your­fuel­gas­supplier.

­ •­FINALLY,­let­the­fuel­gas­service­person­and­the­firefighters­ check­for­escaped­gas.­Have­them­air­out­the­building­and­ area­before­you­return.­Properly­trained­service­people­must­ repair­any­leaks,­check­for­further­leakages,­and­then­relight­ the­appliance­for­you.

ODOR FADING - NO ODOR DETECTED

•­Some­people­cannot­smell­well­in­which­case­they­may­not­ be­able­to­smell­the­odor­of­the­man-made­chemical­added­to­ propane­(LP)­or­natural­gas.­You­must­determine­if­you­can­ smell­the­odorant­in­these­fuel­gases.

­ •­Learn­to­recognize­the­odor­of­propane­(LP)­gas­and­natural­ gas.­Local­propane­(LP)­gas­dealers­will­be­more­than­happy­ to­give­you­a­scratch­and­sniff­pamphlet.­Use­it­to­become­ familiar­with­the­fuel­gas­odor.

­ •­Smoking­can­decrease­your­ability­to­smell.­Being­around­ an­odor­for­a­period­of­time­can­affect­your­sensitivity­to­ that­particular­odor.­Odors­present­in­animal­confinement­ buildings­can­mask­fuel­gas­odor.

•­ The odorant in propane (LP) gas and natural gas is colorless and the intensity of its odor can fade under some circumstances.

­ •­If­there­is­an­underground­leak,­the­movement­of­gas­through­ the­soil­can­filter­the­odorant.

­ •­Propane­(LP)­gas­odor­may­differ­in­intensity­at­different­ levels.­Since­Propane­(LP)­gas­is­heavier­than­air,­there­may­be­ more­odor­at­lower­levels.

• Always be sensitive to the slightest gas odor. If­you­ continue­to­detect­any­gas­odor,­no­matter­how­small,­treat­ it­as­a­serious­leak.­Immediately­go­into­action­as­discussed­ previously.

4 Operating Instructions and Owner’s Manual

SAFETY PRECAUTIONS

­ •­Propane­(LP)­gas­has­a­distinctive­odor.­Learn­to­recognize­ these­odors.­(Reference­Fuel­Gas­Odor­and­Odor­Fading­ sections­above).

­ •­Even­if­you­are­not­properly­trained­in­the­service­and­repair­ of­the­heater,­ALWAYS­be­consciously­aware­of­the­odors­of­ propane­(LP)­gas­and­natural­gas.

­ •­If­you­have­not­been­properly­trained­in­repair­and­service­of­ propane­(LP)­gas­then­do­not­attempt­to­light­heater,­perform­ service­or­repairs,­or­make­any­adjustments­to­the­heater­on­ the­propane­(LP)­gas­fuel­system.

­ •­A­periodic­sniff­test­around­the­heater­or­at­the­heater’s­ joints;­i.e.­hose,­connections,­etc.,­is­a­good­safety­practice.­If­ you­smell­even­a­small­amount­of­gas,­CONTACT­YOUR­FUEL­

GAS­SUPPLIER­IMMEDIATELY.­DO­NOT­WAIT!

FOR SAFE OPERATION

A. READ INSTRUCTIONS CAREFULLY: ­Read­and­adhere­to­ these­instructions.­Do­not­allow­anyone­who­has­not­read­the­ instructions­to­assemble,­light,­adjust­or­operate­the­heater.

WARNING

KEEP­THE­HEATER­OUT­OF­THE­REACH­OF­CHILDREN­

B. Use­only­in­accordance­with­local­codes­or,­in­the­absence­of­ local­codes,­with­the­standard­for­the­Storage­and­handling­of­

Liquefied­Petroleum­Gases.

C. PROPANE IS VERY FLAMMABLE: ­In­the­event­of­a­leak,­ propane­will­accumulate­and­the­possibility­of­a­fire­is­ present.­Propane­gas­is­scented­and­its­strong­odor­is­readily­ detectable.­Never­strike­a­match­or­bring­any­flame­or­create­ an­electric­spark­in­an­enclosure­when­you­smell­propane­gas.­

Ventilate­the­area­thoroughly,­move­the­heater­outside,­find­ and­correct­the­source­of­the­leak­before­attempting­to­light­ any­appliance.­If­you­are­unsure­of­these­instructions­evacuate­ immediately­and­call­for­help.­

D. GAS LEAKAGE: If­the­leak­cannot­be­corrected­do­not­ tamper­with­the­heater,­follow­the­shut­down­instructions­and­ return­the­heater­to­the­dealer­or­address­given­on­last­page.

WARNING

DO­NOT­USE­THIS­HEATER­ON­BULK­TANKS­OF­GREATER­

CAPACITY­THAN­20­POUNDS­LPG­(50­POUNDS­WATER­

CAPACITY).­

E. LEAK DETECTION: ­Before­each­use­of­the­heater­check­all­ fittings­and­connections­with­a­soapy­water­solution­to­be­ sure­there­are­no­leaks.­NEVER­USE­ANY­FLAME­FOR­LEAK­

TEST.­

F. CONNECTING HEATER TO PROPANE CYLINDER: ­Always­ connect­the­heater­to­the­bulk­cylinder­in­the­outdoors­or­in­a­ well­ventilated­area.­NEVER­connect­this­heater­to­a­cylinder­ near­an­open­flame.­

G. USE OF HEATER: ­Always­operate­the­heater­with­ the­propane­cylinder­in­an­upright­position­on­a­level­ noncombustible­surface.­NEVER­place­the­cylinder­on­its­side­ when­operating­the­heater.­

H. ATTEND HEATER: ­Do­not­leave­heater­unattended­while­it­is­ in­operation.­

I. ALWAYS LIGHT HEATER WITH LONG MATCH or LONG

NECK LIGHTER : NEVER ­attempt­to­light­the­heater­with­a­ flint­igniter.­

J. DO NOT TAMPER: Should­the­heater­not­perform­properly,­ such­as­little­or­no­heat­when­operating­in­the­“Hi”­position,­ or­for­any­other­reason,­DO­NOT­ATTEMPT­TO­REPAIR­OR­

TAMPER­with­the­heater.­Any­tampering­could­make­the­ use­of­the­heater­unsafe­and­dangerous.­Return­the­heater­ to­the­dealer­or­the­address­given­on­last­page­for­repair­or­ replacement.­

K. For­optimal­performance­position­the­heater­so­the­ thermocouple­is­opposite­of­the­prevailing­wind­direction.­

Figure­4

L. DO NOT TRANSPORT OR MOVE APPLIANCE WHILE

IN OPERATION. FOLLOW SHUTDOWN AND STORAGE

INSTRUCTIONS TO TRANSPORT OR MOVE THIS

APPLIANCE.

WIND­DIRECTION

Figure­4­

THERMOCOUPLE

Mr. Heater |540T Gas-Fired Infra-Red Tank Top Heater 5 Operating Instructions and Owner’s Manual

LIGHTING INSTRUCTIONS

A. ­Inspect­heater­before­each­use,­check­all­fittings­and­ connections­with­a­soapy­water­solution.­ NEVER USE A

MATCH TO CHECK FOR LEAKS.

­Should­a­gas­leak­occur,­do­ not­attempt­to­repair­or­use­heater.­Return­the­heater­to­your­ dealer­or­the­address­given­on­back­page.­

B.

­­Fuel­–­This­heater­must­be­used­only­with­a­vapor­withdrawal­

LP­gas­bulk­cylinder.­THE­BULK­TANK­MUST­BE­EQUIPPED­

WITH­A­STANDARD­POL­VALVE.

WARNING

USE­PROPANE­GAS­ONLY­AND­CYLINDERS­MARKED­IN­

ACCORDANCE­WITH­THE­SPECIFICATIONS­OF­THE­U.S.­

DEPARTMENT­OF­TRANSPORTATION­(DOT­SPEC.39).­DO­NOT­

USE­ANY­OTHER­TYPE­OF­FUEL.­SEE­YOUR­PROPANE­DEALER­

IF­YOU­HAVE­ANY­QUESTIONS­REGARDING­FUEL.­

C.

­­Turn­the­heater’s­“Hi-Med-Lo-Off”­regulator­knob­to­“HI”­

(clockwise).­

D.

­­To­light­the­MH540T,­depress­and­hold­the­Safety­Shutoff­

Valve.­While­holding­the­Safety­Shutoff­Valve­button­ immediately­light­heater­through­the­hole­on­the­base­of­the­ reflector.­Figure­5

CAUTION: ­­Immediately­light­heater­after­depressing­in­valve­ to­avoid­excessive­build­up­of­propane­gas.

E.

­­After­the­heater­is­lit,­continue­to­hold­the­Safety­Shutoff­

Valve­for­60­seconds,­then­release­the­button.

F.

­­ If­burner­does­not­light­within­10­seconds,­turn­the­heater’s­ regulator­knob­to­“off”­(counter­clockwise)­and­allow­at­least­ five­minutes­for­gas­to­dissipate­before­attempting­to­relight.­

G.

­­Adjust­heat­output­by­turning­regulator­knob­to­desired­ position.­(LOW,­MEDIUM,­HI)

H. Pull­on­lever­to­adjust­heater­to­the­desired­tilted­angle­ operating­position.­Figure­6

I. DO NOT USE THIS HEATER FOR COOKING.

SHUTDOWN AND STORAGE

INSTRUCTIONS

A.

­­­­When­shutting­OFF­the­heater,­make­sure­heater­is­in­the­ upright­position­and­not­at­any­angle,­then­turn­the­regulator­ knob­on­the­heater­to­the­OFF­position­(turning­counter­ clockwise).

B.

CAUTION: ­After­turning­the­unit­OFF,­the­heater­will­remain­ extremely­hot.­Allow­at­least­15­minutes­for­cooling­before­ handling­and­storing.

C.

­­­Detach­heater­from­bulk­tank­before­handling­and­storage.­

REMEMBER-POL­on­hose­fitting­is­a­left-hand­thread.

D.

HEATER STORAGE: ­Indoor­storage­of­the­heater­is­ permissible­only­if­the­cylinder­is­disconnected­and­removed­ from­the­heater.­Cylinders­must­be­stored­outdoors­out­of­ the­reach­of­children­and­must­not­be­stored­in­a­building,­ garage,­or­another­enclosed­area.­Store­cylinders­only­in­ accordance­with­the­“Standard­for­Storage­and­Handling­of­

Liquefied­Petroleum­Gases­ANSI/NFPA­58­and­CSA­B149.1,­

Natural­Gas­and­Petroleum­Installation­Code.­Installation­

Code.”

E.

MAINTENANCE: ­Keep­any­obstruction­from­within­venturi­ tubes­by­blowing­compressed­air­(80­psi­max).­Direct­the­ compressed­air­through­the­venturi­tube­toward­the­burner­ plenum­so­that­dust­collected­on­the­grid­screen­will­be­blown­ outward.­Keep­face­away­from­the­grid­screen.

SLIDE LIGHTER

THROUGH HOLE

ON REFLECTOR

Figure­5­

Mr. Heater |540T Gas-Fired Infra-Red Tank Top Heater

Figure­6­

6 Operating Instructions and Owner’s Manual

Gently pull on lever to tilt burner

WARNING

Air­Quality­Hazard

•­Do­not­use­this­heater­for­heating­human­living­quarters.­

•­Use­of­direct-fired­heaters­in­the­construction­environment­can­result­in­exposure­to­levels­of­CO,­CO2,­and­NO2­considered­to­be­hazardous­to­health­and­potentially­life­threatening.­

•­Do­not­use­in­unventilated­areas.­

•­Know­the­signs­of­CO­and­CO2­poisoning.­

•­Headaches,­stinging­eyes­

•­Dizziness,­disorientation­

•­Difficulty­breathing,­feels­of­being­suffocated­

•­Proper­ventilation­air­exchange­(OSHA­29­CFR­1926.57)­to­support­combustion­and­maintain­acceptable­air­quality­shall­ be­provided­in­accordance­with­OSHA­29­CFR­Part­1926.154,­ANSI­A10.10­Safety­Requirements­for­Temporary­and­Portable­Space­Heating­Devices­and­Equipment­used­in­the­Construction­Industry­or­the­Natural­Gas­and­Propane­Installation­Codes­CSA­B149.1.­

•­Periodically­monitor­levels­of­CO,­CO2­and­NO2­existing­at­the­construction­site­–­at­the­minimum­at­the­start­of­ the­shift­and­after­4­hours.

•­Provide­ventilation­air­exchange,­either­natural­or­mechanical,­as­required­to­maintain­acceptable­indoor­air­quality.

USA­8-Hr­Time­weighted­average

(OSHA­29­CFR­1926.55­App­A)

Canada­8-hr­time­weighted­average

WorkSafe­BC­OHS­Guidelines­Part­5.1

and­Ontario­Workplaces­Reg­833

CO

CO

2

NO

2

50­ppm

5000­ppm

25­ppm

5000­ppm

3­ppm­(Reg­833)

USA­–­Ceiling­Limit

(Short­Term­Exposure­Limit­=­15­minutes)

Canada­STEL­(15­minutes­Reg­833/1­hour­

WSBC)­WorkSafe­BC­OHS­Guidelines­Part­

5.1­and­Ontario­Workplaces­Reg­833

CO

CO

2

NO

2

5­ppm

100­ppm

15000­ppm­(WSBC)

30000­ppm­(Reg­833)

1.0­ppm­(WorkSafeBC)

5.0­ppm­(Reg­833)

•­Ensure­that­the­flow­of­combustion­and­ventilation­air­exchange­cannot­become­obstructed.­

•­As­the­building­‘tightens­up’­during­the­construction­phases­ventilation­may­need­to­be­increased.

Installation­of­this­appliance­at­altitudes­above­2000­ft­(610­m)­shall­be­in­accordance­with­local­codes,­or­in­the­absence­of­ local­codes,­the­National­Fuel­Gas­Code,­ANSI­Z223.1/NFPA­54,­or­National­Standard­of­Canada,­Natural­Gas­and­Propane­

Installation­Code,­CSA­B149.1

The­heater­has­been­shipped­from­the­factory­set­up­for­operation­on­propane­gas.

Mr. Heater |540T Gas-Fired Infra-Red Tank Top Heater 8 Operating Instructions and Owner’s Manual

OPERATING INSTRUCTIONS

AND OWNER’S MANUAL

Model­#

MH540T

Gas-fired Infra-Red

Tank Top Heater

CYLINDER­NOT­INCLUDED

WARNING:

USE­ONLY­MANUFACTURER’S­REPLACEMENT­PARTS.­USE­OF­ANY­OTHER­PARTS­

COULD­CAUSE­INJURY­OR­DEATH.­REPLACEMENT­PARTS­ARE­ONLY­AVAILABLE­

DIRECT­FROM­THE­FACTORY­AND­MUST­BE­INSTALLED­BY­A­QUALIFIED­SERVICE­

AGENCY.

PARTS ORDERING INFORMATION:

PURCHASING:

Accessories­may­be­purchased­at­any­Mr.­Heater­Products­local­dealer­or­direct­from­ the­factory­

FOR INFORMATION REGARDING SERVICE: www.mrheater.com

Please­call­Toll-Free­800-251-0001

Our­office­hours­are­8:00­AM­–­5:00­PM,­EST,­Monday­through­Friday.

Please­include­the­model­number,­date­of­purchase,­and­description­of­problem­in­all­ communication.

LIMITED WARRANTY

Mr.­Heater,­Inc.­warrants­its­heaters­and­accessories­to­be­free­from­defects­in­ material­and­workmanship­for­a­period­of­1­year­from­date­of­purchase.­Mr.­Heater,­

Inc.­will­repair­or­replace­this­product­free­of­charge­if­it­has­been­proven­to­be­ defective­within­the­1-year­period,­and­is­returned­at­customer­expense­with­proof­of­ purchase­to­Mr.­Heater,­Inc.­within­the­warranty­period.

This­warranty­gives­you­specific­legal­rights,­and­you­may­also­have­other­rights­which­ vary­from­state­to­state.

Mr.­Heater,­Inc.­reserves­the­right­to­make­changes­at­any­time,­without­notice­or­ obligation,­in­colors,­specifications,­accessories,­materials­and­models.

PRODUCT­REGISTRATION:­­Thank­you­for­your­purchase.­­

Please­log­in­to­http://www.egiregistration.com­to­register­your­product.

Mr.­Heater,­Inc.,­4560­W.­160TH­ST.,­CLEVELAND,­OHIO­44135­•­800-251-0001

Mr.­Heater­are­registered­trademarks­of­Mr.­Heater,­Inc.

©­2020,­Mr.­Heater,­Inc.­All­rights­reserved

Mr. Heater |540T Gas-Fired Infra-Red Tank Top Heater 10 Operating Instructions and Owner’s Manual

MODE­D’EMPLOI­ET­MANUEL­DU­PROPRIÉTAIRE

CHAUFFAGE INFRAROUGE À

BOUTEILLE DE GAZ

MODÈLE­#

MH540T

LISEZ ATTENTIVEMENT LES INSTRUCTIONS: Lisez­et­suivez­toutes­les­instructions.­Rangez­les­ instructions­dans­un­endroit­sûr­pour­des­réfèrences­future.­Ne­pas­laissez­quelqu’un­qui­n’a­pas­lu­ ces­instructions­assembler,­allumer,­adjuster­ou­faire­fonctionner­la­chauferrette.

CYLINDRE DE PROPANE NON INCLUS

LANGUES INCLUS:

•ANGLAIS

•FRANÇAIS

AVERTISSEMENT:

Si les informations dans ce manuel ne sont pas suivies à la lettre, un incendie ou une explosion peuvent être causés, entraînant des dommages matériels, des blessures ou des pertes de vie.

—­ Ne­pas­entreposer­ou­utiliser­d’essence­ou­d’autres­vapeurs­et­liquides­inflammables­à­proximité­ de­cet­ou­tout­autre­appareil.

—­ Une­bouteille­de­propane­non­branchée­ne­doit­pas­être­entreposée­à­proximité­de­cet­appareil­ou­ de­tout­autre­appareil.

—­ QUE­FAIRE­EN­CAS­D’ODEUR­DE­GAZ:

­ •­ Ne­pas­allumer­l’appareil.

­ •­ Éteindre­toute­flamme­

­ •­ Coupez­l’alimentation­en­gaz­de­l’appareil.­

—­ NE­PAS­LAISSER­LE­RADIATEUR­SANS­SURVEILLANCE­OU­L’­UTILISER­PENDANT­LE­SOMMEIL.

­Ceci­est­un­appareil­de­chauffage­portatif­au­gaz­non­ventilé.­Il­fonctionne­avec­l’air­présent­dans­la­ zone­où­il­est­utilisé.­Combustion­et­l’air­de­ventilation­doivent­être­fournis.­

www.mrheater.com

800-251-0001 42652

WARNING:

LOS COMBUSTIBLES USADOS EN EQUIPOS

PARA LICUAR GAS PROPANO, ASÍ COMO LOS

PRODUCTOS DE SU COMBUSTIÓN, PUEDEN

EXPONERTE A SUSTANCIAS QUÍMICAS, ENTRE

ELLAS EL BENCENO, QUE EL ESTADO DE

CALIFORNIA RECONOCE COMO CAUSA DE CÁNCER

Y DE MALFORMACIONES CONGÉNITAS Y OTROS

DAÑOS AL SISTEMA REPRODUCTOR. PARA MÁS

INFORMACIÓN, WWW.P65WARNINGS.CA.GOV

AVERTISSEMENT :

VOTRE­SÉCURITÉ­EST­IMPORTANTE­

POUR­VOUS­ET­POUR­LES­AUTRES,­PAR­CONSÉQUENT­VEUILLEZ­

LIRE­CES­DIRECTIVES­AVANT­DE­FAIRE­FONCTIONNER­CET­

APPAREIL­DE­CHAUFFAGE.

AVERTISSEMENT DE DANGER GÉNÉRAL:

LE­NON-RE-SPECT­DES­MESURES­DE­PRÉVENTION­ET­DES­

INSTRUC-TIONS­FOURNIES­AVEC­CET­APPAREIL­DE­CHAUFFAGE­

RISQUE­DE­CAUSER­LA­MORT,­DES­BLESSURES­GRAVES­ET­DES­

DOMMAGES­OU­DES­PERTES­MATÉRIELLES­RÉSULTANT­D’INCENDIE,­

D’EXPLOSION,­DE­BRÛLURE,­D’ASPHYXIE,­D’INTOXICATION­AU­

MONOXYDE­DE­CARBONE­ET/OU­D’ÉLECTROCUTION.­SEULES­

LES­PERSONNES­APTES­À­COM-PRENDRE­ET­À­RESPECTER­LES­

INSTRUCTIONS­DEVRAIENT­UTILISER­OU­EFFECTUER­LE­SERVICE­DE­

CET­APPAREIL­DE­CHAUFFAGE.­SI­VOUS­AVEZ­BESOIN­D’AIDE­OU­

D’INFORMATION­CONCERNANT­LA­FOURNAISE­TELS­QUE­MANUEL­

D’IN-STRUCTIONS,­ÉTIQUETTES,­ETC.,­VEUILLEZ­COMMUNIQUER­

AVEC­LE­FABRICANT.

AVERTISSEMENT :

LES­CARBURANTS­UTILISÉS­DANS­

LES­APPAREILS­À­DES­PRODUITS­CHIMIQUES,­NOTAMMENT­LE­

BENZÈNE,­CONNU­EN­CALIFORNIE­POUR­CAUSER­LE­CANCER­ET­

CAUSER­DES­MALFORMATIONS­CONGÉNITALES­OU­D’AUTRES­

PROBLÈMES­DE­REPRODUCTION.­WWW.P65WARNINGS.CA.GOV.

AVERTISSEMENT:

NON­CONÇU­POUR­UNE­

UTILISATION­À­L’INTÉRIEUR­DE­LA­MAISON­OU­DANS­UN­

VÉHICULE­RÉCRÉATIF.

ADVERTENCIA:

DANGER­D’INCENDIE,­D’INHALATION­

ET­D’EXPLOSION.­GARDEZ­LES­COMBUSTIBLES­SOLIDES­TELS­

QUE­LES­MATÉRIAUX­DE­CONSTRUCTION­LE­PAPIER­ET­LE­

CARTON­À­UNE­DISTANCE­SÉCURITAIRE­DE­L’APPAREIL­DE­

CHAUFFAGE­TEL­QUE­RECOMMANDÉ­DANS­LES­INSTRUCTIONS.­

N’UTILISEZ­JAMAIS­LA­FOURNAISE­DANS­UN­ENDROIT­QUI­

CONTIENT­OU­RISQUE­DE­CONTENIR­DES­COMBUSTIBLES­

VOLATILES­OU­EN­SUSPENSION­DANS­L’AIR,­OU­DES­PRODUITS­

TELS­QUE­DE­L’ESSENCE,­DES­SOLVANTS,­DU­DILUANT­À­

PEINTURE,­DES­PARTICULES­DE­POUSSIÈRE­OU­DES­PRODUITS­

CHIMIQUES­INCONNUS.

AVERTISSEMENT:

CE­PRODUIT­PEUT­VOUS­EXPOSER­

À­PLOMB­ET­COMPOSÉS­DE­PLOMB,­IDENTIFIÉ­PAR­L’ÉTAT­DE­

CALIFORNIE­COMME­POUVANT­CAUSER­LE­CANCER.­LAVEZ-

VOUS­LES­MAINS­APRÈS­AVOIR­MANIPULÉ­CE­PRODUIT.­POUR­

DE­PLUS­AMPLES­INFORMATIONS,­PRIÈRE­DE­CONSULTER­

WWW.P65WARNINGS.CA.GOV.

AVERTISSEMENT:

LE­MONOXYDE­DE­CARBONE­

PEUT­VOUS­TUER­L’UTILISATION­D’UN­APPAREIL­DE­CHAUFFAGE­

DE­CAMPING­PORTATIF­À­GAZ­DANS­UNE­TENTE,­UN­VÉHICULE­

RÉCRÉATIF,­UNE­ROULOTTE,­UNE­VOITURE,­UN­ABRI­OU­

TOUT­AUTRE­ENDROIT­FERMÉ­PRODUIT­DU­MONOXYDE­DE­

CARBONE,­UN­GAZ­MORTEL.

CONTENTS

AVERTISSEMENTS­........................................................................

2

CARACTÉRISTIQUES­.....................................................................

2

MONTAGE­ET­RACCORDEMENT­D’INFORMATION­.......................

3

VENTILATION...............................................................................

3

LA­DISTANCE­MINIMALE­ENTRE­MATÉRIAUX­COMBUSTIBLES­.....

4

AVERTISSEMENT­D’­ODEUR­.........................................................

4

PRÉCAUTIONS­DE­SÉCURITÉ­........................................................

5

INSTRUCTIONS­D’ALLUMAGE­......................................................

6

ARRÊT­ET­STOCKAGE­INSTRUCTIONS­..........................................

6

LISTE­DES­PIECES­.........................................................................

7

GARANTIE­.................................................................................10

INSTRUCTIONS­POUR­COMMANDE­DE­PIÈCES­..........................10

Le chauffage est conçu et approuvé pour nous comme, un chauffage de construction et conformément à ANSI

Z83.7- CSA 2.14. Vérifiez avec votre autorité de sécu rité de feu locale si vous avez des questions à propos des applications.

D’autres normes gouvernent l’utilisation de gaz du combustible et produits produisant chaleur et applica tions spécifiques. Vos autorités locales peuvent vous conseiller de ces normes.

CARACTÉRISTIQUES

A.

­­Le­MH540T­est­un­appareil­de­propane­à­haute­pression­et­ conçu­pour­être­branchés­sur­une­cuve­de­propane.­­

B .­­­­Ce­radiateur­est­pour­le­chauffage­temporaire­de­bâtiments­en­ cours­de­construction,­les­modifications­ou­la­réparation.

C.

­­Cet­appareil­est­équipé­d’un­robinet­d’arrêt­de­sécurité­ automatique.­Le­flux­de­gaz­arrêtera­automatiquement­si­le­ chauffage­ne­fonctionne­pas­pour­une­raison­quelconque.­

D.

­­un­maximum­de­sécurité­et­de­commodité­ont­étè­construits­ dans­un­systéme­contrôlant­la­valve­au­débit­suivant:­Faible-

Moyen-Élevé.­Le­tableau­suivant­liste­la­consommation­de­BTU­ par­heure­de­la­bouteille­de­propane.­

PARAMÈTRES BTU SORTIE

FAIBLE 30,000

TEMPS DE

FONCTIONNEMENT

14­HEURES

MOYEN

HIGH

36,000 12­HEURES

45,000 9.5­HEURES

**TEMPS exploitation à l’aide 20LB LP TANK CYLINDRE**

PRESSION MINIMALE

D’ALIMENTATION:

20­PSI­(138kPa)

PRESSION D’ADMISSION

MAX.-­17­PSI­(117kPa)

PRESSION MAXIMALE

D’ALIMENTATION:

La­pression­du­réservoir

MIN.­-­9­PSI­(62kPa)

•Temp­ambiante­minimale­=­20°F­(-6.7°C)

•Poids­net­de­l’unité:­(5.5lbs­/2.5kg)

Mr. Heater | Appareil de chauffage sur bonbonne, à infrarouge, alimenté au gaz.

2 Instructions de fonctionnement et guide d’utilisation

INFORMATION D’ASSEMBLAGE ET DE

RACCORDEMENT

1.

­ Le­chauffage­de­modél­MH540T­est­un­ensemble­ complet.le­cylindre­de­propane­n’est­pas­inclus.­

2.

­ Rétirer­le­chauffage­du­carton.­

3.

­ Cet­appareil­doit­être­utilisé­uniquement­avec­une­ bouteille­de­gaz­de­propane­LP­destiné­à­être­soutiré­ pour­l’utilisation­à­l’état­gazeux­et­équipé­d’une­valve­ standard­POL.­Ne­pas­utiliser­ce­chauffage­sur­une­cuve­ de­propane­de­20­livres­de­GPL(­50­livres­d’eau).

4. Fixez­col­du­réservoir­(Figure­1.)

•­ Le­support­du­réservoir­doit­être­monté­avant­que­ le­chauffage­puisse­être­attaché­au­réservoir­de­ propane.

•­ Alignez­les­trous­de­vis­sur­le­réservoir­support­de­ collier­avec­les­trous­de­vis­dans­la­plaque­centrale­ de­telle­sorte­que­le­chauffage­est­orientée­vers­le­ haut­une­fois­attaché­à­cylindre­collier.

•­ Visser­ensemble­les­pièces­du­réservoir­en­ulilisant­ les­3­vis­emballés.­

•­ Assurez-­vous­que­le­support­du­reservoir­est­ surement­sécurisé­au­chauffage­puis­glisser­le­ support­dans­le­col­de­la­bouteille­de­propane.­

Une­fois­en­place,­fixer­le­chauffage­sur­le­col­de­la­ bouteille­de­propane­en­tournant­le­bouton­dans­le­ sens­horaire­jusqu’a­le­serrer.­

5.

­ ­­Assurez-vous­que­le­régulateur­du­chauffage­est­en­ mode­“OFF”.­Insérez­le­tuyau­dans­la­valve­du­réservoir­ et­tourner­le­bouton­dans­le­sens­contraire­de­la­montre­ tout­en­le­serrant.­Ne­pas­trop­serrer.­(Figure­2)

6.

­ Fonctionner­uniquement­sur­une­surface­plane­et­stable.­

7.

­ Ouvrir­lentement­le­réservoir­de­propane.

8.

­ Vérifiez­tous­les­raccords­pour­les­fuites.­Appliquer­une­ solution­d’eau­savonneuse­(50/50)­sur­tous­les­joints.­

La­formation­de­bulles­nous­avertira­de­la­présence­de­ fuite­au­niveau­des­connections.­Veillez­corriger­toutes­ fuites­avant­de­continuer.

TR

O

US

­DE

­VIS

1

Alignez­les­trous­ de­vis­de­la­section­1­à­2­

3­Vis

TROUS­DE­VIS

2

•­Tourner­le­bouton­dans­le­sens­ de­la­montre­tout­en­attrapant­ fermement­la­poignée­de­la­ bouteille­de­gaz.

D.

COMMANDE­DU­RÉGU-

LATEUR­BOUTON­

Figure­2

RACCORD­BOUTON­

AVERTISSEMENT

­ Ne­jamais­toucher­le­chauffage­pendant­son­utilisation­pour­éviter­les­blessures.­Déplacez­le­chauffage­en­ saisissant­attentivement­la­bouteille­de­propane­

9.

­­ Le­chauffage­doit­être­inspecté­avant­toute­utilisation­ au­moins­annuellement­par­une­personne­certifiée.

10.

­L’ensemble­des­tuyaux­doit­être­visuellement­­inspecté­ avant­l’utilisation­du­chauffage.­Si­il­est­évident­qu’il­ y’­a­une­usure­par­abrasion­excessive­ou­que­le­tuyau­ est­endommagé,­il­doit­être­remplacé­avant­que­le­ chauffage­soit­remis­en­marche.­Les­tuyaux­remplacés­ doivent­être­de­la­même­marque­que­ceux­de­Mr.­

Heater­comme­indiqué­dans­la­liste­des­pièces..

VENTILATION

A. AVERTISSEMENT: Cet appareil est un appareil non ventilé et doit être utilisé que dans un endroit bien ventilé. Ne­ jamais­tenter­de­faire­fonctionner­le­chauffage­à­l’intérieur­ d’un­véhicule,­une­caravane­ou­une­clôture.

B.

UTILISABLE DANS LES ENCEINTES NON-RÉSIDENTIELLES

ET À L’EXTÉRIEURE .­TOUTE­COMBUSTION­A­BESION­ET­

CONSOMME­DE­L’OXYGÈNE­ET­PRODUIT­DU­MONOXYDE­

DE­CARBONE.­ CET APPAREIL DOIT ÊTRE FOURNI D’UNE

VENTILLATION ADÉQUATE.

­NE­PAS­UTILISER­L’APPAREIL­À­

L’­INTÉRIEUR­D’­UNE­MAISON,­UNE­CARAVANE,­UNE­TENTE­

OU­TOUT­ENDROIT­MAL­AÉRÉ.­­

C. AVERTISSEMENT: Fournir­une­ventilation­suffisante.­

Cet­appareil­de­chauffage­consomme­de­l’air­(oxygène).­

Pour­éviter­de­mettre­en­danger­votre­vie­NE­PAS­utiliser­ cet­appareil­dans­des­structures­non­ventilées.­Fournir­ une­ventilation­supplémentaire­pour­tous­les­appareils­à­ combustion­et­des­occupants­supplémentaires.­

­­Le­débit­de­combustion­et­de­la­ventillation­de­l’air­ne­doit­pas­

être­obstrué.

Figure­1­

Mr. Heater | Appareil de chauffage sur bonbonne, à infrarouge, alimenté au gaz.

3 Instructions de fonctionnement et guide d’utilisation

LA DISTANCE MINIMALE ENTRE

MATÉRIAUX COMBUSTIBLES

A .­­Pendant­l’utilisation,­les­surfaces­du­chauffage­sont­extrêtement­ chaudes.­Gardez­les­sacs­de­couchage,­les­vêtements­et­tous­ les­matériaux­combustibles­loin­du­chauffage­d’­au­moins­des­ distances­indiquées­dans­la­figure­3.­

B. AVERTISSEMENT: Pour­éviter­des­blessures­ou­des­ dommages­ne­laissez­jamais­des­vêtements,­des­tentes­ou­ d’autres­matériaux­combustibles­dans­les­91.44­cm­de­la­face­ de­l’appareil.­Cet­appareil­doit­être­situé­à­au­moins­71.12­cm­ au-dessus­du­niveau­du­sol­lors­de­l’utilisation.­Ne­jamais­faire­ fonctionner­l’appareil­et­s’endormir.­

C. AVERTISSEMENT: Ne­jamais­diriger­la­sortie­de­chaleur­de­ cet­appareil­de­chauffage­vers­un­réservoir­de propane­dans­ les­609.6­cm.­

36

48 ”

36 ”

27 ”

LIQUIDATION­DE­COMBUSTIBLES

BTU/HR.­Rating

Modèle BTU­ d’entrée

MH540T

30,000-

36,000-

45,000

Figure­3­

AVANT

36”

CÔTÉS ARRIÈRE HAUT EN­BAS

36” 36” 48” 27”

ODEUR FADE AVERTISSEMENT

AVERTISSEMENT

Danger D’asphyxie

•­ Ne­pas­utiliser­cet­appareil­pour­chauffer­des­pièces­d’­ habitations.

•­­ Ne­pas­utiliser­dans­les­zones­non­ventilées.

•­­ Le­débit­de­combustion­et­de­la­ventillation­de­l’air­ne­doit­ pas­être­obstrué.

•­­ Une­ventillation­adéquate­doit­être­fournie­à­l’appareil­ pour­supporter­la­combustion­pendant­son­utilisation.

•­­ Se­réferer­à­la­section­des­spécifications­de­ce­manuel,­

à­l’étiquette­du­chauffage,­ou­contactez­l’usine­pour­ déterminer­les­besoins­de­la­combustion­du­chauffage.

•­­ Un­maque­de­ventillation­adéquat­conduira­à­une­ mauvaise­combustion.

•­­ Une­mauvaise­combustion­peut­conduire­à­une­intoxication­ au­monoxyde­de­carbone­causant­des­blessures­graves­ ou­la­mort.­Les­symptômes­de­l’intoxication­au­monoxyde­ de­carbone­peuvent­inclure­des­maux­de­tête,­des­

étourdissements­et­des­difficultés­à­respirer

ODEUR DE GAZ COMBUSTIBLE

LP et le gaz naturel ont des odorants artificiels ajoutés pour la détection spécifique des fuites de gaz combustible. Si une fuite de gaz se produit, vous devriez être capable de sentir le gaz combustible. Étant donné que le propane est plus lourd que l’air, vous devriez sentir l’odeur de celui qui est faible à l’ étage à gaz. TOUT ODEUR DE GAZ EST UN APPEL

À LA PRISE D’ACTION!

­ •­Ne­pas­prendre­toute­action­qui­pourrait­enflammer­le­gaz­ combustible.­Ne­pas­faire­fonctionner­les­commutateurs­

électriques.­Ne­pas­débrancher­l’appareil­ou­les­rallonges.­Ne­ pas­allumer­d’allumettes­ou­tout­autre­source­de­flamme.­Ne­ pas­utiliser­votre­téléphone.

­ •­Évacuer­l’­immeuble..

­ •­Fermer­la­bouteille­de­propane­ou­la­principale­valve­ d’alimentation­en­carburant­situé­au­compteur­si­vous­utilisez­ le­gaz­naturel.

­ •­Le­gaz­de­propane­est­plus­lourd­que­l’air.­il­doit­donc­être­ installé­dans­une­zone­basse.­Lorsque­vous­avez­des­raisons­ de­soupçonner­une­fuite,­gardez­la­bouteille­hors­de­toute­ zone­basse.

­ •­Utilisez­le­téléphone­de­votre­voisin­et­appelez­votre­ fournisseur­de­gaz­combustible­et­de­votre­service­d’incendie.­

Ne­pas­rentrer­dans­le­bâtiment­ou­la­zone.

­ •­Restez­en­dehors­du­bâtiment­et­loin­de­la­zone­jusqu’à­ce­ que­déclarée­sûre­par­les­pompiers­et­votre­fournisseur­de­gaz­ combustible.

­ •­Enfin,­laisser­la­personne­du­service­de­gaz­et­les­pompiers­ vérifier­pour­les­fuites­de­gaz.­Demandez­leur­d’­aérer­le­ bâtiment­et­la­zone­avant­d’­y­retourner.­Des­personnes­ certifiées­devraient­réparer­les­fuites,­vérifier­pour­toutes­ eventuelle­fuites­et­rallumer­l’­appareil­pour­vous.

PAS D’ODEUR DETECTÉE

•­Certaines­personnes­ne­peuvent­pas­bien­sentir­dans­ce­cas,­ils­ ne­pourriont­pas­être­en­messure­de­sentir­l’odeur­du­produit­ chimique­ajouté­au­propane­ou­au­gaz­naturel..

­ •­Apprenez­à­reconnaître­l’odeur­du­propane­(LP)­et­le­gaz­ naturel.­Le­concessionnaire­local­du­gaz­de­propane­seront­plus­ que­ravis­de­vous­donner­une­brôchure­des­odeurs.

­ •­Fumer­peut­diminuer­votre­capacité­de­sentir.­Être­autour­ des­odeurs­pendant­un­certain­temps­peut­affecter­votre­ sensibilité­à­cette­odeur­pariculière.­les­odeurs­présentes­ dans­les­bâtiments­contenant­des­animaux­peuvent­masquer­ l’odeur­de­gaz.

•­ L’odorant dans le propane (GPL) et le gaz naturel est incolore et l’intensité de son odeur peut disparaître dans certaines circonstances.

­ •­Si­il­ya­une­fuite­souterraine,­le­mouvement­du­gaz­dans­le­sol­ peut­filtrer­l’odorant.

­ •­L’­odeur­de­gaz­de­propane­peut­varier­en­intensité­à­des­ niveaux­différents.­Étant­donné­que­Le­gaz­de­propane­est­ plus­lourd­que­l’air.,­il­doit­être­installé­dans­une­zone­basse.

• Toujours être sensible à la moindre odeur de gaz. Si­vous­ continuez­à­détecter­toute­odeur­de­gaz­peu­importe­leur­ taille,­traitez­le­comme­une­sérieuse­fuite.­Prendre­desmésures­ immédiatement­comme­indiquées­précédemment.

Mr. Heater | Appareil de chauffage sur bonbonne, à infrarouge, alimenté au gaz.

4 Instructions de fonctionnement et guide d’utilisation

PRÉCAUTIONS DE SÉCURITÉ

­•­Le­gaz­de­propane­a­une­odeur­particulière.­Apprenez­à­le­ recônnaitre.­(­Réferez­vous­aux­sections­précédentes).

•­Même­si­vous­n’êtes­pas­correctement­formés­dans­le­service­ et­la­réparation­de­l’appareil­de­chauffage,­TOUJOURS­être­ conscient­des­odeurs­de­propane­(LP)­et­du­gaz­nature.

•­Si­vous­n’­aviez­pas­reçu­une­formation­adéquate­dans­la­ réparation­et­le­service­de­propane­alors­ne­tentez­pas­ d’allumer­le­chauffage­ou­d’­effectuer­des­réparations­ou­des­ adjustements­sur­le­système­de­la­bouteille­de­gaz­à­propane.

•­Si­vous­n’­aviez­pas­reçu­une­formation­adéquate­dans­la­ réparation­et­le­service­de­propane­alors­ne­tentez­pas­ d’allumer­le­chauffage­ou­d’­effectuer­des­réparations­ou­ des­adjustements­sur­le­système­de­la­bouteille­de­gaz­à­ propane.­Si­vous­sentez­une­odeur­de­même­une­petite­ quantité­de­gaz,­CONTACTEZ­VOTRE­FOURNISSEUR­DE­GAZ­

COMBUSTIBLE­IMMÉDIATEMENT.­N’ATTENDS­PAS!

POUR UN FONCTIONNEMENT SÛR

A. LISEZ ATTENTIVEMENT LES INSTRUCTIONS: Lire­et­ respecter­ces­instructions.­Ne­pas­laissez­quelqu’un­qui­n’a­pas­ lu­les­instructions­d’­assembler,­d’­allumer,­d’­adjuster­ou­de­ fonctionner­le­chauffage.

AVERTISSEMENT

­ GARDER­LE­CHAUFFAGE­HORS­DE­LA­PORTÉE­DES­ENFANTS

B. Utiliser­uniquement­conformément­aux­codes­locaux­ou,­en­ l’absence­de­codes­locaux,­à­la­norme­pour­le­stockage­et­la­ manipulation­des­gaz­de­pétrole­liquéfiés.

C.­­ Le propane est très inflammable :­Dans­le­cas­d’une­fuite,­ le­propane­sera­accumulé­et­la­possibilité­d’un­incendie­est­ présent.­LLe­gaz­de­propane­a­une­odeur­et­celle­ci­est­facile­

à­détecter.­Ne­jamais­allumer­une­allumette­ou­creer­une­

étincelle­dans­une­zone­où­vous­sentez­le­gaz­de­propan.­

Aérer­la­zone­à­fond,­déplacer­l’appareil­à­l’extérieur,­trouver­ et­corriger­la­source­de­la­fuite­avant­de­tenter­d’allumer­ l’appareil.­Si­vous­n’êtes­pas­sûr­de­ces­instructions­évacuer­ immédiatement­et­appeler­à­l’aide.

D.­­ FUITE DE GAZ: ­Si­la­fuite­ne­peut­pas­être­corrigée,­ne­pas­ trafiquer­l’­appareil,­suivez­les­instructions­de­fermeture­et­ retourner­le­chauffage­au­distrubuteur­ou­à­l’adresse­­indiquée­

à­la­dernière­page.

AVERTISSEMENT

­ Ne­pas­utiliser­cet­appareil­sur­un­réservoir­de­capacité­ de­plus­de­20­livres­(50­livres­de­capacité­d’eau).

E. DÉTECTION DE FUITE: Avant­chaque­utilisation­de­l’appareil­ de­chauffage­vérifier­tous­les­raccords­et­les­connexions­avec­une­ solution­d’eau­savonneuse­pour­être­sûr­qu’il­n’y­a­pas­de­fuites.­

NE­JAMAIS­VÉRIFIER­LA­PRÉSENCE­DE­FUITE­À­L’AIDE­D’UNE­

FLAMME.

F. CONNEXION DU CHAUFFAGE à la bouteille de propane:

Toujours­connecter­l’appareil­au­cylindre­à­l’­extérieur­ou­dans­ un­endroit­bien­aéré.­Ne­jamais­faire­la­connexion­à­proximité­ d’une­flamme.­

G. UTLISATION DU CHAUFFAGE: Toujours­faire­fonctionner­ le­chauffage­avec­la­bouteille­de­propane­dans­une­position­ verticale­sur­une­surface­à­niveau­incombustible.­Ne­jamais­ placer­le­cylindre­sur­son­côté­pendant­l’­utilisation­de­ l’appareil.­

H. Assistance: Ne­pas­laisser­sans­surveillance­l’appareil­pendant­ son­fonctionnement .

I. TOUJOURS ALLUMER LE CHAUFFAGE AVEC UNE LONGUE

ALLUMETTE: Ne­jamais­tenter­d’allumer­le­chauffage­avec­ un­brique.­

J. Ne pas trafiquer: Si­le­chauffage­ne­fonctionne­pas­ convenablement,­comme­un­peu­ou­pas­de­chaleur­lors­ de­l’utilisation­dans­la­position­“Hi”,­ou­pour­toute­autre­ raison,­na­pas­tenter­de­réparer­ou­de­trafiquer­l’appareil.­

Toute­falsification­pourrait­rendre­l’­utilisation­de­l’­appareil­ dangereuse.­Retouner­le­chauffage­au­distributeur­ou­à­l’­ adresse­indiquée­à­la­dernière­page­pour­les­réparation­ou­ remplacement.

K.­Pour­performance­optimale,­positionez­le­chauffage­de­sorte­ que­le­thermocouple­est­opposé­à­la­direction­du­vent.­

­ Figure­4

L. NE PAS TRANSPORTER OU DÉPLACER APPAREIL

PENDANT LE FONCTIONNEMENT. SUIVRE LES

INSTRUCTIONS DE FERMETURE ET DE RANGEMENT POUR

TRANSPORTER OU DÉPLACER CET APPAREIL.

DIRECTION­DU­VENT

Figure­4­

Mr. Heater | Appareil de chauffage sur bonbonne, à infrarouge, alimenté au gaz.

5 Instructions de fonctionnement et guide d’utilisation

THERMOCOUPLE

INSTRUCTIONS D’ALLUMAGE

A. ­Inspecter­le­chauffage­avabt­chaque­utilisation,­vérifiez­que­ tous­les­raccord­avec­une­solution­d’­eau­savonneuse.­ NE

JAMAIS UTILISER UNE ALLUMETTE POUR VÉRIFIER LES

FUITES .­Si­une­fuite­de­gaz­se­produit­,­na­pas­tenter­de­ réparer­ou­d’­utiliser­le­chauffage.­retourner­le­chauffage­au­ distrubuteur­ou­à­l’adresse­­indiquée­à­la­dernière­page

B.­­Carburant­-­cet­appareil­doit­être­utilisé­uniquement­avec­le­ gaz­propane­destiné­à­être­soutiré­pour­l’utilisation­à­l’état­ gazeux.­Le­réservoir­doit­être­équipée­d’une­valve­standar­

POL.

AVERTISSEMENT

­ UTILISER­LE­GAZ­DE­PROPANE­UNIQUEMENT­ET­DES­

BOUTEILLES­MARQUÉES­CONFORMÉMENT­AUX­

SPÉCIFICATIONS­DU­MINISTÈRE­DE­TRANSPORT­

DES­ÉTAT-UNIS.­NE­PAS­UTILISER­AUTRE­TYPE­DE­

CARBURANT.­VOIR­LE­CONCESSIONNAIRE­DE­GAZ­

SI­VOUS­AVEZ­DES­QUESTIONS­CONCERNANT­LE­

CARBURANT.

C.

­­Tournez­le­bouton­“Salut-Med-Lo-Off”­régulateur­de­l’appareil­ de­chauffage­à­«HI»­(dans­le­sens­horaire).­

D.

­­Pour­allumer­le­MH540T,­appuyer­et­maintenez­la­valve­ de­sécurité.­tout­en­maintenant­la­valve­de­sécurité,­ immediatement­allumer­le­chauffage­à­travers­le­trou­sur­la­ base­du­réflecteur­Figure­5

ATTENTION: Immédiateemnt­allumer­le­chauffage­après­avoir­­ enfoncéla­valve­por­éviter­une­accumulation­ excessive­de­gaz­de­propane.

E.

­­­Après­que­le­chauffage­soit­allumé,­continuez­à­enfoncer­la

­ valve­pour­60­s,­puis­relâchez­le­bouton.

F .­­­Si­le­brûleur­ne­s’allume­pas­dans­les­10­s,­tourner­le­bouton

­ à­la­position­“off”­et­laissez­passer­5­minutes­pour­que­le­ gaz­se­dissipe­avant­de­tenter­de­rallumer.G.­ajuster­la­sortie­ de­chaleur­en­tournant­le­bouton­du­régulateur­à­la­position­ désirée.­(Faible,­moyen,­élevé)

H.

­Tirez­sur­le­levier­pour­ajuster­le­chauffage­à­la­position­ désirée­de­fonctionnement­de­l’angle­incliné.­Figure­6

I. NE PAS UTILISER CE CHAUFFAGE POUR LA CUISSON.

INSTRUCTIONS POUR LA FERMETURE ET

LE RANGEMENT

A.

­­Lors­de­la­fermeture­du­chauffage,­assurez-vous­de­chauffage­ est­en­position­verticale­et­non­à­un­angle,­puis­tourner­le­ bouton­du­régulateur­sur­le­chauffage­en­position­OFF­(en­ tournant­dans­le­sens­antihoraire).

B.­­ ATTENTION: ­Après­extinction­de­l’appareil,­l’appareil­de­ chauffage­restera­extrêmement­chaud.­Prévoyez­au­moins­15­ minutes­pour­le­réfroidissement­avant­de­le­manipuler­et­de­ stocker.

C.­­Détacher­le­chauffage­du­réservoir­avant­la­manipulation­et­le­ rangement.­Rappelez­vous­que­POL­sur­le­tuyau­is­un­filetage­

à­gauche..

D.­­ RANGEMENT DU CHAUFFAGE: ­Le­rangement­à­l’­intérieur­ de­l’appareil­est­admissible­seulement­si­la­bouteille­est­ débranchée­et­retirée­du­chauffage.­Les­cylindres­doivent­

être­rangés­à­l’­extérieur­­ors­de­la­portée­des­enfants­et­ne­ doivent­pas­être­rangés­dans­un­bâtiment,­un­garage­ou­un­ espace­clos.­Ranger­des­bouteilles­conformément­à”­Standard­ for­storage­and­handling­of­Liquefied­Petroleum­Gases­ANSI­

/­NFPA­58­et­CSA­B149.1,­gaz­naturel­et­du­pétrole­Code­ d’installation.­Code­d’installation.­“

E.­­ ENTRETIEN: ­Gardez­toute­obstruction­à­de­l’intérieur­des­ tubes­de­venturi­par­soufflage­d’air­comprimé­(80­psi­max).­

Diriger­l’air­comprimé­à­travers­le­tube­venturi­vers­le­plenum­ du­brûleur­afin­que­la­poussière­recueillie­sur­l’écran­de­la­grille­ sera­soufflé­vers­l’extérieur.­Gardez­le­visage­loin­de­l’écran­de­ la­grille.

FAIRE PASSER

L’ ALLUMETTE

À TRAVERS LE

TROU SUR LE

RÈFLECTEUR

Figure­5­

Mr. Heater | Appareil de chauffage sur bonbonne, à infrarouge, alimenté au gaz.

6

Figure­6­

Instructions de fonctionnement et guide d’utilisation

TIREZ DOUCEMENT

SUR LE LEVIER

POUR INCLINER LE

BRÛLEUR

AVERTISSEMENT

Danger­de­la­qualité­de­l’air

•­N’utilisez­pas­cet­appareil­de­chauffage­pour­le­chauffage­des­locaux­d’habitation­humaine.

•­L’utilisation­des­appareils­de­chauffage­direct­dans­les­environnements­de­construction­peut­vous­exposer­à­des­niveaux­ de­CO,­CO2,­et­NO2,­qui­sont­considérés­comme­dangereux­pour­la­santé­et­potentiellement­mortels.­

•­Ne­pas­utiliser­dans­les­zones­non­ventilées.­

•­Connaissez­les­signes­d’empoisonnement­au­CO­et­CO2.­

•­Maux­de­tête,­brûlure­des­yeux­

•­Vertige,­désorientation­

•­Difficulté­à­respirer,­sensation­d’étouffement­

•­Un­échange­d’air­de­ventilation­adéquat­(OSHA­29­CFR­1926.57)­pour­supporter­la­combustion­et­maintenir­une­qualité­ de­l’air­acceptable­est­fournie­selon­OSHA­29­CFR­partie­1926.154,­ANSI­A10.10­Exigences­de­sécurité­pour­les­appareils­et­équipements­de­chauffage­portables­et­temporaires­utilisés­dans­l’industrie­de­la­construction­ou­les­Codes­CSA­ pour­le­gaz­naturel­et­le­gaz­propane­CSA­B149.1.

•­Surveiller­périodiquement­les­niveaux­de­CO,­de­CO2­et­de­NO2­existants­sur­le­site­de­construction­–­à­tout­le­ moins­au­début­du­quart­de­travail­et­après­4­heures.­

•­Prévoir­un­échange­d’air­de­ventilation,­soit­naturel­ou­mécanique,­tel­que­requis­pour­maintenir­une­qualité­de­l’air­ intérieur­acceptable.

Moyenne­pondérée­dans­le­temps­sur­8­ heures,­États-Unis

(OSHA­29­CFR­1926.55­App­A)

Moyenne­pondérée­dans­le­temps­sur­8­ heures,­Canada­Directives­SST­de­Work-

Safe­BC­partie­5.1­et­Règlement­sur­les­ milieux­de­travail­en­Ontario­833

CO

CO

2

NO

2

CO

CO

2

NO

2

50­parties­par­million

5000­parties­par­million

É.-U.­-­Limite­de­plafond­(limite­ d’exposition­à­court­terme­=­15­minutes)

5­parties­par­million

25­parties­par­million

5000­parties­par­million

3­parties­par­million­(Reg­833)

Directives­de­SST­Canada­STEL­(15­minutes­

Rég.­833­/­1­heure­WSBC)­de­WorkSafe­

BC­partie­5.1­et­Règlement­sur­les­milieux­ de­travail­en­Ontario­833

100­parties­par­million

15000­parties­par­million­(WSBC)

30000­parties­par­million­(Reg­833)

1.0­parties­par­million­(WorkSafeBC)

5.0­parties­par­million­(Reg­833)

•­Assurez-vous­que­le­débit­d’échange­d’air­de­combustion­et­de­ventilation­ne­peut­pas­être­obstrué.

•­La­ventilation­peut­devoir­être­augmentée­à­mesure­que­le­bâtiment­«­durcit­»­lors­des­phases­de­construction.

L’installation­de­cet­appareil­à­une­altitude­supérieure­à­2000­pi­(610­m)­doit­être­conforme­aux­codes­locaux,­ou­en­ l’absence­de­codes­locaux,­le­National­Fuel­Gas­Code,­ANSI­Z223.1/NFPA­54,­ou­la­norme­nationale­du­Canada,­le­Code­ pour­le­gaz­naturel­et­le­gaz­propane,­CSA­B149.1.­

L’appareil­de­chauffage­a­été­expédié­de­l’usine,­configuré­pour­fonctionner­au­gaz­propane.

Mr. Heater | Appareil de chauffage sur bonbonne, à infrarouge, alimenté au gaz.

8 Instructions de fonctionnement et guide d’utilisation

MODE D’EMPLOI ET MANUEL

DU PROPRIÉTAIRE

MODÈLE­#

MH540T

CHAUFFAGE INFRA-

ROUGE À BOUTEILLE

DE GAZ

CYLINDRE­NON­INCLUS

AVERTISSEMENT:

UTILISER­UNIQUEMENT­LES­PIÈCES­DE­RECHANGE­VENANT­DU­FABRICANT.­

L’UTILISATION­DE­TOUT­AUTRES­PIÈCES­POURRAIT­CUASER­DES­BLESSURES­OU­LA­

MORT.­LES­PIÈCES­DE­RECHANGE­SONT­UNIQUEMENT­DISPONSIBLE­DIRECTEMENT­

DE­L’­USINE­ET­DOIVENT­ÊTRE­INSTALLÉES­PAR­UNE­AGENCE­DE­SERVICE­QUALI-

FIÉ.

COMMANDE DE PIÈCES DÉTACHÉES:

ACHAT:

Les­accessoires­peuvent­être­achetés­à­tout­revendeur­local­Mr.­Heater­Produits­ou­ directement­de­l’usine­

POUR UN SERVICE DE RENSEIGNEMENTS CONCERNANT: www.mrheater.com

S’il­vous­plaît­appelez­sans­frais­800-251-0001

Nos­heures­de­bureau­sont­08:00-17:00,­du­Lundi­au­Vendredi.

S’il­vous­plaît­inclure­le­numéro­de­modèle,­la­date­d’achat,­et­la­description­du­ problème­dans­toutes­les­communications.

GARANTIE LIMITÉE

Mr.­Heater,­Inc.­garantit­que­ses­appareils­de­chauffage­et­les­accessoires­sont­ exempts­de­défauts­de­matériaux­et­de­fabrication­pour­une­période­de­1­an­à­ compter­de­la­date­d’achat.­Mr.­Heater,­Inc.­réparera­ou­remplacera­ce­produit­ gratuitement­si­il­a­été­prouvé­être­défectueux­pendant­la­période­de­1­an,­et­est­ retourné­aux­frais­du­client­avec­preuve­d’achat­à­Mr.­Heater,­Inc.­au­sein­de­la­ garantie­point­final.

Certains­états/provinces­ne­permettent­pas­de­limitation­de­durée­des­garanties­ implicites­ou­tacites,­aussi,­la­limitation­ou­les­exclusions­ci-dessus­peuvent­ne­pas­ s’appliquer­à­vous.­Bien­que­cette­garantie­vous­confère­des­droits­légaux­spécifiques,­ vous­pourriez­avoir­d’autres­droits­qui­varient­d’un­état/province­à­l’autre.

Mr.­Heater,­Inc.­se­réserve­le­droit­d’apporter­des­modifications­à­tout­moment,­ sans­préavis­ni­obligation,­les­couleurs,­les­caractéristiques,­les­accessoires,­les­matériaux­et­les­modèles

ENREGISTREMENT­DU­PRODUIT:­Merci­pour­votre­achat.

S’il­vous­plaît­vous­connecter­à­http://www.egiregistration.com­pour­enregistrer­votre­produit.

Mr.­Heater,­Inc.,­4560­W.­160TH­ST.,­CLEVELAND,­OHIO­44135­•­800-251-0001

Mr.­Heater­are­registered­trademarks­of­Mr.­Heater,­Inc.

©­2020,­Mr.­Heater,­Inc.­All­rights­reserved

Mr. Heater | Appareil de chauffage sur bonbonne, à infrarouge, alimenté au gaz.

10 Instructions de fonctionnement et guide d’utilisation

advertisement

Related manuals

Download PDF

advertisement