elero RolTop Series Manual
elero RolTop Series: Below you will find brief product information for your newly purchased device, helping you understand its capabilities and potential use cases.
elero RolTop Series is a tubular motor drive designed for roller shutters, providing automated control and enhanced convenience. Here are some key features and applications:
-
Automated Operation: The drive enables motorized operation of roller shutters, allowing you to open, close, or adjust them with ease using switches or remote controls.
-
Adjustable End Positions: You can set specific upper and lower limit positions for the roller shutter's travel, ensuring it stops automatically at desired points.
Advertisement
Advertisement
GB
RolTop roller shutter drive
Keep these instructions in a safe place!
After installation of the tubular drive attach these instructions to the cable for the electrician.
Device functions:
• Blind protection (torque limiting)
• Commissioning the drive with the assembly cable.
As-delivered condition (commissioning mode)
• Setting end positions
Warning!
Important safety instructions!
Observe the following instructions.
Risk of injury due to electrocution.
The connections to the 230 V mains must be made by authorised specialist personnel.
Check the system (roller shutter) regularly for wear or damage.
The regulations of the local energy supply company as well as the regulations for wet and damp rooms according to VDE 0100 must be followed when making the connections.
Only use unmodified original elero electrical parts.
Keep people away from the system until it is stationary.
When working on the system (servicing, cleaning windows etc.), always disconnect it from the mains supply.
Check the following before installation:
• The drive is only capable of operation as installed.
• Only perform connecting work with the power turned off.
• The blind must be attached to the winding shaft.
• The profile tube must have sufficient clearance from the motor tube.
• Make sure there is sufficient axial play (1–2 mm)
Installation in profile tubes
Push drive with relevant adapter and limit switch into the profile tube.
Protect the motor cable in order to avoid it brushing against the roller shutter. Avoid kinking the cable.
Secure the counterpart support to prevent axial movement, e.g. screw or rivet on idler.
Secure the drive axially in the support.
Attach the blind to the shaft!
A
C
B
Installation
Warning!
Observe the following installation instructions!
– The drive must be fixed in such a way that it does not endanger personnel.
– Before installing the drive, all lines and equipment, which are not required for operation, must be removed from the site.
– During installation, during operation and when work is carried out on the system, the option to separate all three poles from the mains must always exist (Hirschmann connector and
Hirschmann coupling or a two-pole switch with minimum 3 mm contact gap or all-pole main switch).
– If the drive is controlled by a switch with OFF pre-setting (dead man’s button), the momentary contact switch must be fitted at a height of more than 1.50 m and separated from the moving parts.
The travel range of the systems must always be visible during operation.
– Moving parts in a drive, which are below 2.5 m, must be guarded.
– Set torque and set operating time must be adapted to the requirements of the product which is driven.
– Please note the technical data on the type plate.
– Please note that with this drive (type M motor) the smallest internal tube diameter corresponds with 46 mm.
– The drive must be installed so that it cannot get wet.
– Do not install drives in surroundings which are at risk of explosion or in mobile appliances
(e.g. motor vehicles).
– Keep children away from the (remote) control unit.
Remove of the motor cable plug
Warning!
Risk of injury due to electrocution.
When the motor cable plug is removed the supply line must be volt free.
Delivery condition Remove plug Insert plug
Warnung!
Risk of injury due to electrocution.
Do not drill in the area of the motor!
2
S
S
1
S
3
Remove the motor cable plug
Switch off voltage supply.
1. Press locking mechanism on the plug towards the cable using a screwdriver.
2. Pull out the plug.
Insert the motor cable plug
3. Switch off voltage supply. Insert plug until locking mechanism engages.
2
Connection/Installation/Commissioning
Types of installation
Different types of installation are possible:
Type of installation Possible with
1. Upper/lower limit position T-strap, tapes, freely programmable belt
2. Fixed upper stop lower stop freely adjustable
3. Fixed upper and lower stop
T-strap, tapes, belt, limit plugs, angle bracket
Anti push-up device, limit plugs, angle bracket
4. Upper limit position freely programmable fixed lower limit stop
Anti push-up device
Start up
Note: The drive is in commissioning mode when the roller shutters are delivered.
Assembly cable connection
1.
Mains
Blue (neutral wire) (1)
Black (2)
Brown (3)
Green-yellow
3
1
2
3
1
2
Connection example, RolTop Rohrmotor 230 V/50 Hz
Note:
The motor controls in up/down direction must be locked against each other.
Condenser
Electronics
A reversing delay of at least 0,5 sec. must be ensured.
Winding thermostat
Motor cable plug
2. Switch on mains.
You can now set the end positions with the assembly cable.
Please note: Press the travel key until the drive signals the transition into the programming mode, by a short automatic STOP.
You can now program the end positions.
Junction box
(outside of roller shutter case)
Note: The blind protection system is only adapted to the blind after a complete, uninterrupted upwards and downwards travel.
interlocked push button or momentary contact switch
1 0 2
Mains 230V/50 Hz
L1
N
PE
Switch box
Note: You can connect several RolTop drives in parallel.
Please note the maximum control capacity of the control unit.
Exception
In the case of RolSmart M-K drives, parallel connection is only possible in conjunction with a cut-off relay.
End position setting
Installation Method 1: Upper/lower limit position freely programmable
Installation Method 1: Upper/lower limit position freely programmable
Note: Ensure that the equipment is correctly connected.
STOP
STOP
1. Move the blind up to approx. 5 cm before the desired upper limit stop.
The drive starts up slowly with a short STOP.
4. Press the DOWN momentary contact switch again.
Move the blind down until it is a short distance above the desired lower limit stop.
The drive starts up slowly with a short STOP.
2. Press the UP momentary contact switch again.
Go to the desired upper end position.
It is possible to make corrections using the momentary contact switches.
5. Travel to the desired lower limit stop.
It is possible to make corrections using the momentary contact switches.
STOP
STOP
3. Press the DOWN momentary contact switch until the drive stops automatically.
The upper limit stop is programmed.
6. Press the UP momentary contact switch until the drive stops automatically.
The lower limit has been set.
Setting of the end positions is now complete.
3
4
End position setting
Installation Method 2: Fixed upper stop/lower stop freely adjustable
Installation Method 2: Fixed upper stop/ lower stop freely adjustable
Note: Ensure that the equipment is correctly connected.
STOP
STOP
4. Press the DOWN momentary contact switch again.
Move the blind down until it is a short distance above the desired lower limit stop.
The drive starts up slowly with a short STOP.
1. Move the blind up to approx. 5 cm before the upper limit stop.
The drive starts up slowly with a short STOP.
STOP
5. Travel to the desired lower limit stop.
It is possible to make corrections using the momentary contact switches.
2. Press the UP momentary contact switch again.
Approach the upper limit stop.
The drive switches off automatically when it reaches the limit stop.
STOP
STOP
3. Press the DOWN momentary contact switch until the drive stops automatically.
The upper limit stop is programmed.
6. Press the UP momentary contact switch until the drive stops automatically.
The lower limit has been set.
Setting of the end positions is now complete.
End position setting
Installation Method 3: Fixed upper and lower stop
Installation Method 3: Fixed upper und lower limit stops
Note: Ensure that the equipment is correctly connected.
STOP
STOP 4. Press the DOWN momentary contact switch again.
Run the blind until shortly before the lower limit stop.
The drive starts up slowly with a short STOP.
1. Move the blind up to approx. 5 cm before the upper limit stop.
The drive starts up slowly with a short STOP.
STOP
STOP
5. Approach the lower limit stop.
The drive switches off automatically when it reaches the limit stop.
2. Press the UP momentary contact switch again.
Approach the upper limit stop.
The drive switches off automatically when it reaches the limit stop.
STOP
STOP
3. Press the DOWN momentary contact switch until the drive stops automatically.
The upper limit stop is programmed.
6. Press the UP momentary contact switch until the drive stops automatically.
The lower limit has been set.
Setting of the end positions is now complete.
5
6
End position setting
Installation Method 4: Upper stop freely adjustable/fixed lower stop
Installation Method 4: Upper stop freely adjustable/ fixed lower stop
Note: Ensure that the equipment is correctly connected.
STOP
STOP
4. Press the DOWN momentary contact switch again.
Run the blind until shortly before the lower limit stop.
The drive starts up slowly with a short STOP.
1. Move the blind up to approx. 5 cm before the desired upper limit stop.
The drive starts up slowly with a short STOP.
STOP
5. Approach the lower limit stop.
The drive switches off automatically when it reaches the limit stop.
2. Press the UP momentary contact switch again.
Go to the desired upper end position.
It is possible to make corrections using the momentary contact switches.
STOP
STOP
3. Press the DOWN momentary contact switch until the drive stops automatically.
The upper limit stop is programmed.
6. Press the UP momentary contact switch until the drive stops automatically.
The lower limit has been set.
Setting of the end positions is now complete.
Changing/Deleting the limit positions
Changing/Deleting the limit positions
Mains
Blue (neutral wire) (1)
Black (2)
Brown (3)
Green-yellow
1
3
2
1
3
2
1. Switch on mains.
2. Move the blind to an intermediate position.
approx.
5 sec.
3. Press both momentary contact switches on the assembly cable simultaneously .
The drive travels up and down briefly after approx. 5 seconds.
Deletion of the limit positions is complete.
You can now re-programme the limit positions.
7
Troubleshooting
Fault
• Drive stops during travel
• Drive stops after short travel
• Drive runs only in one direction
• Drive does not react
• Drive does not learn in limit positions
Possible cause
• Limit positions are not set
• Drive is in setting mode
• End position programmed
• Roller shutter stiff
• Faulty connection
• No power supply
• Thermostat has triggered
• Random travel
• Travel to limit position/stop too short
Remedy
• Set limit positions
• Set second limit position
• Check smooth running of the roller shutter
• Check connection
• Check mains voltage
• Allow drive to cool down
• Delete limit positions
Re-programme limit positions
• Drive has to travel to short STOP
20
Antriebstechnik
Linsenhofer Straße 59–63
D-72660 Beuren
Telefon (0 70 25) 13-01
Telefax (0 70 25) 13-212 [email protected]
www.elero.com
We reserve the right to make technical changes 08/07

Public link updated