Gorman-Rupp Pumps GRP33-06A Specification 2 Pages
Gorman-Rupp Pumps GRP33-06A Specification
advertisement
Specification Data
B
Sec. 10
AUTOMATIC AIR RELEASE VALVE
PAGE 1490
NOVEMBER 2012
VALVE SPECIFICATIONS
Size: 3/8” x 3/4” (9,6 mm x 19 mm) NPT ‐ Female.
Air Valve: Gray Iron.
Float Chamber: Ductile Iron.
Floats: Rubber.
Linkage: Stainless Steel.
Valve Seat: Stainless Steel.
O‐ring: Buna‐N.
Hardware: Standard Plated Steel.
VALVE
SEAT
Model GRP33‐06A
Size 3/8” x 3/4”
FOR GAS
RELEASE VENT LINE
(TO OUTSIDE)
AIR VALVE
MOUNTING
FOOT
FLOAT ROD
FOR LINE FROM PUMP
GROUP GRIND
FLOATS
FLOAT
CHAMBER
SUMP
VALVE
FOR LINE FROM
PUMP SUCTION
TYPICAL INSTALLATION AND THEORY OF OPERATION
The Air Release Valve is designed with an air valve in the head of the assembly and a sump valve in the base. These valves are controlled by a common rod that is moved vertically by an attached set of floats.
VENT TO OUTSIDE IF INSTALLED
IN PUMP HOUSE (CHECK VALVE
REQUIRED ON DUPLEX
INSTALLATION ONLY)
DISCHARGE LINE CHECK
VALVE (MANDATORY)
DISCHARGE
LINE
AIR RELEASE VALVE
When the pump “A” is started, air is drawn from the suction line into the priming pump and directed through the discharge tube “B” to the Air Release Valve. This air and vapor is then vented to atmosphere through the valve head.
With the float down, sump valve “E” is closed; air cannot re‐enter the suction pip ing through the return tube assembly “C”.
As product fills the pump casing, pressure develops, opening the check valve “D” in the discharge piping. The priming pump delivers product and fills the float cham ber, causing the float to rise, which opens the sump valve “E” and closes the air valve.
SUCTION LINE
GORMAN‐RUPP SELF‐PRIMING
CENTRIFUGAL PUMP
The product recirculates through the return tube assembly “C” to the pump suction. The liquid pressure equalizes the priming pump spring pressure and the priming pump slides into neutral. At this point, the pump is fully primed.
In the neutral position, the priming pump circulates a small amount of liquid through the discharge tube to the float chamber and back to the pump suction through the return tube.
If air or vapor enters the suction piping during the pumping operation, the discharge line check valve closes again and the priming pump again evacuates the air through the Air Release Valve.
THE GORMAN‐RUPP COMPANY
D
MANSFIELD, OHIO
GORMAN‐RUPP OF CANADA LIMITED
D
ST. THOMAS, ONTARIO, CANADA www.grpumps.com
Specifications Subject to Change Without Notice
E
Copyright by the Gorman‐Rupp Company 2012
Printed in U.S.A.
Specification Data
SECTION 10, PAGE 1490
OVERALL DIMENSIONS and
WEIGHTS APPROXIMATE
NET WEIGHT: 40 LBS. [18,1 KG.]
SHIPPING WEIGHTS: 45 LBS. [20,4 KG.]
CARTON: 2.5 CU. FT. [0,07 CU. M.]
FOOTPRINT
DIMENSIONS:
INCHES
[MILLIMETERS]
THE GORMAN‐RUPP COMPANY
D
MANSFIELD, OHIO
GORMAN‐RUPP OF CANADA LIMITED
D
ST. THOMAS, ONTARIO, CANADA
E
Copyright by the Gorman‐Rupp Company 2012
Printed in U.S.A.
advertisement