Graco 310657E Replacement PC Board Kit for Ultra Max II Ultimate MX II 695/795/1095/1595, TexSpray Mark V Owner's Manual

Graco 310657E Replacement PC Board Kit for Ultra Max II Ultimate MX II 695/795/1095/1595, TexSpray Mark V Owner's Manual | Manualzz
Instructions – Parts List
Replacement PC Board Kit for:
Ultra Max II 695/795/1095/1595t
Ultimate Mx II 695/795/1095/1595t
TexSprayt Mark V
Vac
Model
695
120
North America
795
1095
1595
Standard/
Premium
Standard
Premium
Standard
Premium
Standard
Premium
Standard
Premium
R
Ultra Max II
248037
248036
248031
248030
248308
248038
248033
248032
248039
248034
248040*
248747
248035*
248746
Mark V
240
Europe
240
Europe Multi-cord
110
UK
240
Australia
240
Asia
100
Japan & Taiwan
310657E
695
795
1095
Mark V
695
795
1095
Mark V
695
795
1095
Mark V
695
795
1095
695
795
1095
695
795
1095
248042
248041
248043
248044
248046
248045
248047
248048
Ultimate Mx II
826048
826047
826041
826040
826049
826042
826050
826044
826051*
826054
826045*
826053
249029*
249030
249031
249178
248049
248050
248051
249072
248593
248058
248053
248055
248592
248594
248595
248057
248059
248060
248052
248054
248056
* Not ETL approved
All models not available in all countries.
GRACO INC.ąP.O. BOX 1441ąMINNEAPOLIS, MNą55440-1441
Copyright 2004, Graco Inc. is registered to I.S. EN ISO 9001
Pressure Relief Procedure
1. Turn pressure to zero.
WARNING
2. Turn ON/OFF switch to OFF.
INJECTION HAZARD
System pressure must be manually relieved to prevent system
from starting or spraying accidentally. Fluid under high pressure can be injected through skin and cause serious injury.
To reduce risk of injury from injection, splashing fluid, or moving parts, follow Pressure
Relief Procedure whenever you:
D
D
D
D
are instructed to relieve pressure,
stop spraying,
check or service any system equipment,
or install or clean spray tip.
3. Unplug power supply cord.
4. Hold metal part of gun firmly to grounded metal
pail. Trigger gun to relieve pressure.
5. Lock gun safety latch.
6. Open pressure drain valve. Leave pressure drain
valve open until ready to spray again.
If suspected that spray tip or hose is completely
clogged, or that pressure has not been fully relieved
after following steps above, VERY SLOWLY loosen tip
guard retaining nut or hose end coupling to relieve
pressure gradually, then loosen completely. Now clear
tip or hose obstruction.
Installation
1095
795
695
795 EXAMPLE SHOWN
695/795/1095: CUT 2 RESISTORS; LEAVE THE CHOSEN MODEL
120V 1595/Mark V: CUT ALL 3 RESISTORS
240V Mark V: CUT AS 1095
ti4413a
Fig. 1
CAUTION
Electrostatic discharges can damage components on
PC board. Use a ground strap when handling or
installing PC board.
Using configurations other than those specified in
Fig. 1 results in poor sprayer performance.
1. Follow Pressure Relief Procedure.
2. Remove PC board. See Manual 309941 or 309942
for procedure.
3. Fig. 1. Cut resistors from PC board.
4. Install PC board. See Manual 309941 or 309942
for procedure.
TO PLACE AN ORDER OR FOR SERVICE, contact your Graco distributor, or call 1–800–690–2894 to identify the nearest distributor.
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
Graco Headquarters: Minneapolis
International Offices: Belgium, China, Japan, Korea
GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440–1441
www.graco.com
PRINTED IN USA 310657E