Graco 3A6319B, G3 Standard Automatic Lubrication Pump Instructions

Add to my manuals
22 Pages

advertisement

Graco 3A6319B, G3 Standard Automatic Lubrication Pump Instructions | Manualzz

Instructions

G3 Standard Automatic

Lubrication Pump

3A6319B

EN

For dispensing of NLGI Grades #000 to #2 greases. For Professional Use Only.

Not approved for use in explosive atmospheres or hazardous locations.

5100 psi (35.1 MPa, 351.6 bar) Maximum Pump Output Pressure

5000 psi (34.4 MPA, 344.7 bar) Maximum Fill Inlet Pressure

Important Safety Instructions

Read all warnings and instructions in this manual before using this equipment. Save these instructions.

Conforms to ANSI/UL 73

Certified to CAN/CSA

Std. 22.2 No 68-09

3132066

24V and 110-240VAC Pumps ONLY

2

Part / Model Numbers

Part / Model Numbers

The Part Number is a six-digit unique number that is only used to order the G3 Pump. Directly related to this six digit

Part Number is the configured Graco Model Number. This configured number identifies the distinct features of a specific G3 Pump. To help you understand each component that makes up the Model Number see Understanding Your

Model Number, page 3. The tables below shows the relationship between each Part Number and its related Model

Number.

8 Liter Models

96G500

G3-G-24NC-8LTA00-0D00L000

12 Liter Models

96G501 G3-G-24NC-12TA00-0D00L000

16 Liter Models

96G502 G3-G-24NC-16TA00-0D00L000

20 Liter Models

96G503 G3-G-24NC-20TA00-0D00L000

3A6319B

F

IG

. 1

3A6319B h

Part / Model Numbers

Understanding the Model Number

Use the Code Sample provided below to identify each component’s location in the Model Number. The options for each component that make up the code are provided on the lists below.

NOTE: Some pump configurations are not available. Contact Graco Customer Service or your local Graco distributor for assistance.

Code Sample:

G 3 G N C a a b b c c d e f f g h i j k m n p

G3 - G = Identifies pump as being a G3; G = Grease

G3 - A = Identifies pump as being a G3; A = Oil

Code aa: Power Source

24 = 24 Volts DC

Code bb: Operation Control

NC = No Controller

Code cc: Reservoir Capacity (Liters)

• 8L = 8 Liters

• 12 = 12 Liters

• 16 = 16 Liters

• 20 = 20 Liters

Code d: Follower Plate Installed

• T = Follower Plate Installed; Tie Rods

Code e: Low Level Option

• A = Low Level No Controller

Code ff: Options

• 00 = No Options

Code g, h, i, j, k, m, n, p

NOTE: Codes g - p relate to a specific location on the

G3 pump. See F IG . 1 for these locations.

• D = DIN

• 0 = Not populated

• L = Low Level k

3

4

Warnings

Warnings

The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclamation point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When these symbols appear in the body of this manual or on warning labels, refer back to these Warnings. Product-specific hazard symbols and warnings not covered in this section may appear throughout the body of this manual where applicable.

SKIN INJECTION HAZARD

WARNING

High-pressure fluid from dispensing device, hose leaks, or ruptured components will pierce skin. This may look like just a cut, but it is a serious injury that can result in amputation. Get immediate surgical treatment.

• Do not point dispensing device at anyone or at any part of the body.

• Do not put your hand over the fluid outlet.

• Do not stop or deflect leaks with your hand, body, glove, or rag.

Follow the Pressure Relief Procedure

when you stop dispensing and before cleaning, checking, or servicing equipment.

• Tighten all fluid connections before operating the equipment.

• Check hoses and couplings daily. Replace worn or damaged parts immediately.

PRESSURIZED EQUIPMENT HAZARD

Over-pressurization can result in equipment rupture.

• A pressure relief valve is required at each pump outlet.

• Follow the

Pressure Relief Procedure

in this manual before servicing.

3A6319B

3A6319B

Warnings

WARNING

EQUIPMENT MISUSE HAZARD

Misuse can cause death or serious injury.

• Do not operate the unit when fatigued or under the influence of drugs or alcohol.

• Do not exceed the maximum working pressure or temperature rating of the lowest rated system

component. See Technical Specifications

in all equipment manuals.

• Use fluids and solvents that are compatible with equipment wetted parts. See

Technical

Specifications

in all equipment manuals. Read fluid and solvent manufacturer’s warnings. For complete information about your material, request Safety Data Sheets (SDSs) from distributor or retailer.

• Turn off all equipment and follow the

Pressure Relief Procedure

when equipment is not in use.

• Check equipment daily. Repair or replace worn or damaged parts immediately with genuine manufacturer’s replacement parts only.

• Do not alter or modify equipment. Alterations or modifications may void agency approvals and create safety hazards.

• Make sure all equipment is rated and approved for the environment in which you are using it.

• Use equipment only for its intended purpose. Call your distributor for information.

• Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.

• Do not kink or over bend hoses or use hoses to pull equipment.

• Keep children and animals away from work area.

• Comply with all applicable safety regulations.

PLASTIC PARTS CLEANING SOLVENT HAZARD

Many cleaning solvents can degrade plastic parts and cause them to fail, which could cause serious injury or property damage.

• Use only compatible solvents to clean plastic structural or pressure-containing parts.

See Technical Specifications

in all equipment manuals for materials of construction. Consult the solvent manufacturer for information and recommendations about compatibility.

MOVING PARTS HAZARD

Moving parts can pinch, cut or amputate fingers and other body parts.

• Keep clear of moving parts.

• Do not operate equipment with protective guards or covers removed.

• Equipment can start without warning. Before checking, moving, or servicing equipment, follow the

Pressure Relief Procedure

and disconnect all power sources.

PERSONAL PROTECTIVE EQUIPMENT

Wear appropriate protective equipment when in the work area to help prevent serious injury, including eye injury, hearing loss, inhalation of toxic fumes, and burns. Protective equipment includes but is not limited to:

• Protective eyewear, and hearing protection.

• Respirators, protective clothing, and gloves as recommended by the fluid and solvent manufacturer.

5

Installation

Installation

Component Identification - 8 Liter Model Shown

See Parts, page 17 for expanded view.

J

N

H

A

M

K

F

B

D E

L

F IG . 2

Key:

A Reservoir

B Pump Element (1 included. Can accommodate 3 total)

C Pressure Relief Valve (Not shown. Not included / required for

each outlet - Available from Graco. See Parts, page 18.)

D Zerk Inlet Fill Fitting (1 included / grease models only)

E Pump Outlet Plug (2 included)

F Volume Control Spacers (2 included. More spacers = less output volume per stroke) (also see F IG . 9, page 12)

G Fuse (DC models only - Not included, not shown. Available from Graco. See Parts, page 18.)

H Cover

J Top Mounting Bracket

K Bottom Mounting Bracket

L Part Number / Model Number example only shown, (see pages 3, Understanding the Model Number, for details)

M Follower Plate

N Vent Hole for Follower Plate

6 3A6319B

Typical Installation

Series Progressive Divider Valve

Installation

B

C

A

F

F IG . 3

Key

A Connected to fused power source

B Pressure relief valve (Not included; required for each outlet - user supplied)

C Supply Hose (user supplied)

D Series progressive divider valves

E To lube points

D

E

3A6319B 7

Installation

Injector Installations

H B

C

A

F IG . 4

Key

A Connected to fused power source

B Pressure relief valve (Not included; required for each outlet - user supplied)

C Supply Hose (user supplied)

D Injectors

E To lube points

G Vent valve (Not included / available from Graco)

H Return to reservoir

8

G

D

F

E

3A6319B

Installation

Unpacking

NOTICE

Observe precautions for handling electrostatic sensitive devices. Touch ground before handling pump.

Use the five fasteners (included) to secure the

G3 to the mounting surface. 3 fasteners are used for the bottom bracket and 2 fasteners are used for the top bracket.

Adjust top mounting bracket, if necessary to

align the bracket with the mounting surface (F

IG

.

5).

Insert (user supplied) spacers if there is still a gap after adjusting the bracket.

The pump module was carefully packaged for shipment by Graco. When the package arrives, perform the following procedure to unpack the units:

1.

Inspect the shipping box carefully for shipping damage. Contact the carrier promptly if damage is discovered.

2.

Unseal the box and inspect the contents carefully.

There should not be any damaged parts.

3.

Compare the packing slip against all items included in the box. Any shortages or other inspection problems should be reported immediately.

Choosing an Installation

Location

AUTOMATIC SYSTEM ACTIVATION HAZARD

If the system is equipped with has an automatic timer

(user supplied) that activates the pump lubrication system when power is connected or when exiting the programming function, unexpected activation of the system could result in serious injury, including skin injection and amputation.

Before you install or remove the lubrication pump from the system, disconnect and isolate all power supplies and relieve all pressure.

Select a location that will adequately support the weight of the G3 Pump and lubricant, as well as all plumbing and electrical connections.

Refer to the mounting hole layouts provided in the Mounting Bracket Dimensions section of this

manual, page 21. No other installation configu-

ration should be used.

Use designated mounting holes and provided configurations only.

F IG . 5

System Wiring

Fuses

NOTICE

Fuses (user supplied) are required on all DC models. To avoid equipment damage:

• Never operate G3 Pump DC models without a fuse installed.

• A fuse of the correct voltage must be installed in line with the power entry to the system.

Fuse Kits are available from Graco. The following Table identifies the correct fuse to use for your input voltage and the corresponding Graco Kit number.

Input Voltage Fuse Value

24 VDC 4 A

Graco Kit No.

571040

Recommendations for Using Pump in

Harsh Environments

• If using a DIN style power or alarm harness with a right angle mating connector, make sure the connector does not exit the unit in the UP direction.

• Use a corrosion preventative electrical grease on all contacts.

3A6319B 9

Installation

Wiring and Installation Diagrams

The following Table identifies the wiring and installation diagrams for the cable included with the pump provided in this manual.

Power DIN DC - 15 foot

4

Pin and Related Wire Color (F IG . 6)

Pin

1

2

3

Pin Name

-VDC

+VDC

Not Used

Not Used

Color

Black

White

Not Used

Green

Low Level Outputs

See Low Level Output Option, page 14 for functional

description. See Technical Specifications, page 20 for

ratings.

Pins (F IG . 7)

Pin

3

4

1

2

Pin Name

LL N.O.

Not Used

LL COM

Not Used

F IG . 7

F

IG

. 6

10 3A6319B

Setup

Setup

Connecting to Auxiliary Fittings

Pressure Relief Procedure

Follow the Pressure Relief Procedure whenever you see this symbol.

This equipment stays pressurized until pressure is manually relieved. To help prevent serious injury from pressurized fluid, such as skin injection, splashing fluid and moving parts, follow the Pressure Relief

Procedure when you stop dispensing and before cleaning, checking, or servicing the equipment.

Relieve pressure in system using two wrenches working in opposite directions on pump element and pump element fitting to slowly loosen fitting only until fitting is loose and no more lubricant or air is leaking from fitting.

NOTE: When loosening pump element fitting, do NOT loosen pump element . Loosening pump element will change the output volume.

NOTICE

Do not attach unsupported equipment to auxiliary fittings such as fill ports and pump element. Attaching unsupported equipment to these fitting can result in irreparable housing damage.

• Always use two wrenches working in opposite directions when connecting anything to pump element or auxiliary fittings. See F IG . 8 for an example.

• Torque pump element fittings to 50 in. lbs (5.6

N•m).

• When connecting pump element into housing torque to 50 in. lbs (5.6 N•m).

Pressure Relief Valves

To prevent over-pressurization, which can result in equipment rupture and serious injury, a pressure relief valve appropriate for the lubrication system must be installed close to every pump outlet to alleviate unintended pressure rises in the system and protect the G3 pump from damage.

• Only use a pressure relief valve that is rated for no more than the working pressure of any component installed in the system.

• Install a pressure relief valve close to every pump outlet; before any auxiliary fitting.

NOTE: A pressure relief valve can be purchased from

Graco.

F IG . 8

3A6319B 11

Setup

Setting Pump Outlet Volume

NOTE:

• Before making any adjustments to pump volume,

Relieve Pressure

following procedure on page 11.

• Only use Graco supplied spacers to control output volume.

• It may be necessary to repeat this outlet volume setup procedure after the pump is operating to re-adjust the volume of dispensed fluids.

1.

Use a wrench to turn pump element counter-clockwise to loosen. Do not remove entire pump element.

Only back pump element out enough to allow spacer to be slid on or off (F IG . 9).

3.

Tighten pump element fitting. Torque fitting to 50 in. lbs (5.6 N•m).

• The amount of dispensed volume can vary depending on external conditions such as lubricant temperature and back pressure from downstream connections.

• Use of these volume adjustment in conjunction with setting the ON time of the pump will allow for control of the output volume.

• Use these volume adjustments as a starting point and adjust as necessary to ensure desired lubrication dispense.

F IG . 9

2.

If needed, remove or insert spacers to achieve required pump output volume. A tool may be needed to facilitate removal.

Pump volume control is set using either no (0) spacers, 1 or 2 spacers (F IG . 9).

Do not use more than 2 spacers to adjust output volume.

No. Spacers

2

1

0

Output Volume / Minute cubic inches cubic cm

0.12

0.18

0.25

2

3

4

Loading Grease

To ensure optimal performance from the G3:

• Only use NLGI #000 - #2 greases appropriate for your application, automatic dispensing, and the temperature. Consult with machine and lube manufacturer for details.

• The reservoir can be filled using a hand operated pump, pneumatic pump or electric transfer pump.

• Do not overfill.

• Do not operate G3 without reservoir attached.

NOTICE

• Always clean inlet fitting with a clean dry cloth prior to filling reservoir. Dirt and/or debris can damage pump and/or lubrication system.

• Care must be used when filling the reservoir using a pneumatic or electric transfer pump to not pressurize and break the reservoir.

1.

Connect fill hose to inlet fitting.

2.

For higher viscosity fluids, start pump to rotate stirring paddle during fill to prevent air pockets from forming in grease. Do not exceed 30 minutes run time.

For models using an external controller, start pump operation per your controller specifications.

12 3A6319B

Setup

3.

Fill reservoir with grease until seal of follower plate breaches the vent hole (F

IG

. 10) and the majority of air is expelled from the reservoir.

vent hole

F IG . 11

2.

Only run pump until air-free lubricant is dispensed out of element fitting (F IG . 12).

F IG . 10

NOTE: Vent port, located in rear of reservoir, should not be used as an overfill port/indicator.

4.

Remove fill hose.

Priming

NOTE: It is not necessary to prime pump every time pump is filled with lubricant.

Pump only requires priming the first time it is used or if it is allowed to run dry.

1.

Loosen pump element fitting (F IG . 11).

NOTE: When loosening pump element fitting, do NOT loosen pump element . Loosening pump element will change the output volume

F IG . 12

3.

Tighten pump element fitting using two wrenches working in opposite directions (F IG . 11).

3A6319B 13

Pump Operation

Pump Operation

The G3 Pump can be controlled using an external, user supplied, power source and controller.

Refer to the Typical Installation diagrams starting on

page 7 for correct location of the required fuses.

NOTE:

• When using an external power source and controller, Pump ON (Run) Time should be set for no longer than 30 minutes.

• In most cases, Pump OFF (Rest) Time should be twice as long as Pump ON (Run) time. If alternative

ON / OFF times are required, contact Graco Customer Service for assistance.

Low Level Output Option

Some G3 pumps without controllers include a Low Level

Output Option. The low level signal is monitored across

PINS 3 and 4. For PIN 3 and 4 locations and wiring information the Low Level Outputs diagram, page 10.

NOTE: A low level warning is triggered when the controller detects PINS 3 and 4 have momentarily closed.

When the grease level has reached a low warning level,

PINS 3 and 4 momentarily close (1 time per paddle revolution) sending the signal that the fluid has reached a low level to the controller.

To ensure that a low level condition has been met, 3 or more low level triggers must be detected within 1 minute or less.

See F

IG

. 13 for an illustration of a typical Low Level Output response to low grease level.

Typical Low Level Output Response with Low Level Fluids

200 ms

Contact

Position

Closed

Open

3 s

F IG . 13

14 3A6319B

Troubleshooting

Troubleshooting

Problem

Unit does not power on

Unit does not power on (DC models only)

Cause Solution

Incorrect/loose wiring Refer to Installation instructions,

page 6.

Tripped external fuse due to internal component failure

Tripped external fuse due to pumping non-cold weather lubricant in cold weather -13°F (-25°C)

Contact Graco Customer Service.

Replace lubricant with pumpable lubricant, rated for environmental conditions and application.

Lubricant leaks past seal located on the bottom of the reservoir

Reservoir retaining tabs are cracked or broken

Reservoir is being pressurized during filling

Replace fuse.

Replace reservoir.

Ensure vent hole is not plugged.

Failed motor

If problem persists, contact Graco

Customer Service or your local

Graco distributor for assistance.

Replace unit.

Unit not pumping during ON cycle, but controller lights and functions

Follower plate is not going down

Air is trapped in the reservoir between the follower plate and lubricant

Pump takes several minutes before it begins pumping at the highest pump volume setting (no stroke adjust spacers installed)

After wiring and installing equipment pump is not working

Pumping non-cold weather lubricant in cold weather -13°F (-25°C)

Pump wired backwards

Add grease following Loading Grease

instructions, page 12. Ensure air is

purged.

Add 1 stroke adjust spacer and adjust lube cycle time to accommodate the difference in pump volume per stroke.

Rewire pump. See wiring and instal-

lation diagrams, page 10.

3A6319B 15

Maintenance

Maintenance

Frequency

Daily and at refill Zerk Fittings

Component

Daily

Monthly

Cleaning the Reservoir

G3 Pump Unit and Reservoir

External Wiring Harness

Required Maintenance

Keep all fittings clean using a clean dry cloth. Dirt and/or debris can damage pump and/or lubrication system.

Keep pump unit and reservoir clean using a clean dry cloth.

Verify external harnesses are secure.

Only use water or solvents compatible with polycarbonate to clean reservoir.

Most solvents will degrade the polycarbonate reservoir and cause it to fail.

16 3A6319B

Parts

1

27

20

21

3

5

26

Parts

8 Liter Model

2

42

4

32

23

3A6319B

33

22

24

5

40

42

25

16

10

43

36

6

44

31

30

Reservoir for 12 Liter and

Larger Models

(See 8 Liter Model for all other parts)

10

12

21

20

41

29

45

34

17

Parts

Parts

Ref Part Description Qty

4

5

6

1

2

3

10

BASE, three pump housing

SCREW, cap, hex head

RING, snap

COVER

17S695 SEAL, reservoir

BRACKET, top

RESERVOIR, 8 L

RESERVOIR, 12 L

RESERVOIR, 16 L

RESERVOIR, 20 L

12

16

SLEEVE (12 L and larger only)

ROD, support, 8 L

ROD, support, 12 L

ROD, support, 16 L

ROD, support, 20 L

20

ROD, guide, 8 L

ROD, guide, 12 L

ROD, guide, 16 L

ROD, guide, 20 L 1

21

SPRING, compression, 8 L

SPRING, compression, 12 L and larger models (Install springs as

shown in Parts, page 17, Reservoir

for 12 Liter and Larger Models)

22 123026 SEAL, grease, 10 mm id

1

2

1

23

24

NUT

PLATE, follower

1

1

25

26

BEARING, sleeve

PLATE, wiper arm

1

1

1

1

1

1

4

4

4

4

1

1

1

1

1

1

4

1

1

2

Ref

Fuses

Part

Part Description

571040 FUSE, 24 volt DC

Description

Qty

1

Qty

33

34

36

38

39

27

29

30

31

32

ADAPTER, base, reservoir

BRACKET, bottom

COVER, vent

GASKET, vent cover

SEAL, top, foam

SCREW, SHC, 10 x 0.62, sst

WASHER, flat

WASHER, flat

SPACER, pump shim (not shown)

1

1

1

1

1

2

2

2

2

PARTS, bracket mounting (bagged) 1

40

41

42

SCREW, cap, hex head

NUT, jam, Ny-loc

WASHER, plain

43

44

SCREW, M8, 35 mm

NUT, M8

45 571041 KIT, pump element

46 16U790 CABLE, DIN, bare)

47  LABEL, safety

 Replacement Danger and Warning labels, tags and cards are available at no cost.

2

6

6

2

2

1

1

1

18 3A6319B

Parts

Pressure Relief Valves

Important Information regarding Pressure Relief

Valve 16C807.

 Pressure Relief Valve 16C807 can only be used on the G3 Pump.

It is not intended for use with any other products.

The pressure relief valve uses a pressure adjustment screw (a) to set the pressure release point. It is not intended as a way to relieve pressure during normal operation, but as a protective a b measure in the event there is an unintended pressure increase in the system. Do not use this pressure relief valve a means of relieving pressure in day-to-day, normal cycle operation. ti15644 a = adjustment screw b = locking nut

The pressure adjustment screw will require periodic adjustments.

Whenever the valve is set/adjusted (after the set point is found) it is important to ensure that the valve is not bottomed out and there is at least 1/2 turn of adjustment remaining. This is determined by turning the screw (a)

1/2 turn and then back turning it out again.

NOTE: Turning adjustment screw (a) clockwise increases pressure.

Installation and Repair Kits

Kit No.

Description

571026 KIT, output union, 3 pump

571063 KIT, output union, 2 pump

571028

KIT, return to reservoir NPT, includes pressure relief valve 16C807

571071

KIT, return to reservoir BSPP, includes pressure relief valve 16C807

571058 KIT, output adapter, NPT

571070 KIT, output, adapter, BSPP

571060 KIT, fill, zerk, leakproof

25E455 KIT, repair, reservoir 8 liter

25E456 KIT, repair, reservoir, 12 liter

25E457 KIT, repair, reservoir 16 liter

25E458 KIT, repair, reservoir, 20 liter

25E485 KIT, mounting hardware

Manual

Number

3A0523

3A0525

3A0522

NA

3A6385

NA

Part

16C807 

563156

563157

563158

563159

563160

563161

563190

Description

VALVE, pressure relief, 500-3500 psi (3.44

MPa, 34.4 bar - 24.1 MPa, 241 bar), Set pressure 3000 psi + 10% (20.68 MPa, 206.8 bar +

10%) Included in Kit 571028

VALVE, pressure relief, 750 psi (5.17 MPa,

51.71 bar)

VALVE, pressure relief, 1000 psi (6.89 MPa,

68.95 bar)

VALVE, pressure relief, 1500 psi (10.34 MPa,

103.42 bar)

VALVE, pressure relief, 2000 psi (13.78 MPa,

137.89 bar)

VALVE, pressure relief, 2500 psi (17.23 MPa,

172.36 bar)

VALVE, pressure relief, 3000 psi (20.68 MPa,

206.84 bar)

VALVE, pressure relief, 5500 psi (37.92 MPa,

379.21 bar)

Qty

1

1

1

1

1

1

1

1

3A6319B 19

Technical Specifications

Technical Specifications

G3 Standard Automatic Lubrication Pump

Pump Output Pressure

Fill Inlet Pressure

Power

24 VDC

Outputs - Low Level (Dry Contact)

Contact Rating

Switch Rating

Switching Current

Carry Current

Fluid

Pumps

Pump Output

2 spacers per outlet

1 spacer per outlet

0 spacers per outlet

Pump Outlet

Weight

8 Liter Models

12 Liter Models

16 Liter Models

20 Liter Models

Dimensions

Model

8L

12L

16L

20L

Inches

22.36

26.30

30.23

34.17

Height cm

56.79

66.80

76.78

86.79

US

5100 psi

5000 psi

Metric

35.1 MPa, 351.6 bar

34.4 MPa, 344.7 bar

18 - 32 VDC; 2.5 A current, 60 W, inrush/locked rotor 6 A

10 Watts Maximum

200 VDC Maximum

0.5 A Maximum

1.2 A Maximum

Grease NLGI 000 - #2

Up to 3

0.12 in.

3

/minute

0.18 in.

3

/ minute

2 cm

3 cm

3

3

/ minute

/ minute

0.25 in.

3

/ minute 4 cm

3

/ minute

1/4-18 NPSF. Mates with 1/4-18 NPT male fittings

25.1 lb

27.3 lb

28.5 lb

29.7 lb

Inches

8.94

8.94

8.94

8.94

Width cm

22.70

22.70

22.70

22.70

11.39 kg

12.38 kg

12.93 kg

13.47kg

Inches

10.37

10.37

10.37

10.37

Depth cm

26.34

26.34

26.34

26.34

20 3A6319B

Mounting Bracket Dimensions

Mounting Bracket Dimensions

Model

8 L

12L

16L

20L

Inches

16.26

20.20

24.13

28.07

A mm

413.0

508.5

612.9

713.0

3A6319B 21

Graco Standard Warranty

Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by

Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations.

This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.

This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.

THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED

TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE .

Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy

(including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.

GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A

PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT

MANUFACTURED BY GRACO . These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.

In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.

FOR GRACO CANADA CUSTOMERS

The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite de ou en rapport, directement ou indirectement, avec les procédures concernées.

Graco Information

For the latest information about Graco products, visit www.graco.com.

TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor.

Phone: 612-623-6928 or Toll Free: 1-800-533-9655, Fax: 612-378-3590

All written and visual data contained in this document reflects the latest product information available at the time of publication.

Graco reserves the right to make changes at any time without notice.

Original instructions.

This manual contains English. MM 3A6319

Graco Headquarters: Minneapolis

International Offices: Belgium, China, Japan, Korea

GRACO INC. AND SUBSIDIARIES • P.O. BOX 1441 • MINNEAPOLIS MN 55440-1441 • USA

Copyright 2018, Graco Inc. All Graco manufacturing locations are registered to ISO 9001.

www.graco.com

Rev. B, July 2020