INSTRUCTIONS-PARTS LIST

This manual contains important warnings and information.

READ AND KEEP FOR REFERENCE.

INSTRUCTIONS

308–693

Rev. A

Cart-Mounted, Heated Air-Assisted

Airless Package

Refer to page 2 for a List of Models.

Model 231–979 Shown

Table of Contents

List of Models

Warnings

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6

10

2

3

Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Technical Data

Graco Warranty

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Toll-Free Graco Phone Number . . . . . . . . . . . . . . . . .

16

21

22

24

24

GRACO INC.

P.O. BOX 1441 MINNEAPOLIS, MN 55440–1441

COPYRIGHT 1997, GRACO INC.

Graco Inc. is registered to I.S. EN ISO 9001

List of Models

Package

Part No.

Series Pump Model Ratio

231–979

231–980

A

A

President r

, carbon steel

President r

, carbon steel

30:1

30:1

Maximum Fluid

Working Pressure

3000 psi (21 MPa, 210 bar)

3000 psi (21 MPa, 210 bar)

231–982 z

232–005

232–006

232–008 z

232–015

232–016

A

A

A

A

A

A

President r

, carbon steel

Monark r

, stainless steel

Monark r

, stainless steel

Monark r

, stainless steel

President r

, carbon steel

President r

, carbon steel

30:1

15:1

15:1

15:1

15:1

15:1

3000 psi (21 MPa, 210 bar)

1500 psi (10 MPa, 100 bar)

1500 psi (10 MPa, 100 bar)

1500 psi (10 MPa, 100 bar)

1500 psi (10 MPa, 100 bar)

1500 psi (10 MPa, 100 bar)

232–018 z

232–034

232–035

232–037 z

232–049

232–050

232–052 z

A

232–059 A

232–060

A

A

A

A

A

A

A

President r , carbon steel

President r , stainless steel

President r , stainless steel

President r , stainless steel

Monark r , stainless steel

Monark r , stainless steel

Monark r , stainless steel

Monark r , carbon steel

Monark r

, carbon steel

15:1

30:1

30:1

30:1

23:1

23:1

23:1

23:1

23:1

1500 psi (10 MPa, 100 bar)

3000 psi (21 MPa, 210 bar)

3000 psi (21 MPa, 210 bar)

3000 psi (21 MPa, 210 bar)

2300 psi (16 MPa,160 bar)

2300 psi (16 MPa,160 bar)

2300 psi (16 MPa,160 bar)

2300 psi (16 MPa,160 bar)

2300 psi (16 MPa,160 bar) z These 220V packages are only available in Europe.

Maximum Air

Input Pressure

Heater

Voltage

100 psi (0.7 MPa, 7 bar) 120V

100 psi (0.7 MPa, 7 bar) 240V

100 psi (0.7 MPa, 7 bar) 220V

100 psi (0.7 MPa, 7 bar) 120V

100 psi (0.7 MPa, 7 bar) 240V

100 psi (0.7 MPa, 7 bar) 220V

100 psi (0.7 MPa, 7 bar) 120V

100 psi (0.7 MPa, 7 bar) 240V

100 psi (0.7 MPa, 7 bar) 220V

100 psi (0.7 MPa, 7 bar) 120V

100 psi (0.7 MPa, 7 bar) 240V

100 psi (0.7 MPa, 7 bar) 220V

100 psi (0.7 MPa, 7 bar) 120V

100 psi (0.7 MPa, 7 bar) 240V

100 psi (0.7 MPa, 7 bar) 220V

100 psi (0.7 MPa, 7 bar) 120V

100 psi (0.7 MPa, 7 bar) 240V

Symbols

Warning Symbol

WARNING

This symbol alerts you to the possibility of serious injury or death if you do not follow the instructions.

Caution Symbol

CAUTION

This symbol alerts you to the possibility of damage to or destruction of equipment if you do not follow the instructions.

WARNING

EQUIPMENT MISUSE HAZARD

Equipment misuse can cause the equipment to rupture or malfunction and result in serious injury.

INSTRUCTIONS

D This equipment is for professional use only.

D Read all instruction manuals, tags, and labels before operating the equipment.

D

Use the equipment only for its intended purpose. If you are uncertain about usage, call your Graco distributor.

D

Do not alter or modify this equipment. Use only genuine Graco parts and accessories.

D

Check equipment daily. Repair or replace worn or damaged parts immediately.

D Do not exceed the maximum working pressure of the lowest rated system component. Refer to the

Technical Data on page 22 for the maximum working pressure of this equipment.

D Use fluids and solvents which are compatible with the equipment wetted parts. Refer to the Tech-

nical Data section of all equipment manuals. Read the fluid and solvent manufacturer’s warnings.

D Do not use hoses to pull equipment.

D Route hoses away from traffic areas, sharp edges, moving parts, and hot surfaces. Do not expose

Graco hoses to temperatures above 180 _ F (82 _ C) or below –40 _ F (–40 _ C).

D Wear hearing protection when operating this equipment.

D

Do not lift pressurized equipment.

D

Comply with all applicable local, state, and national fire, electrical, and safety regulations.

WARNING

INJECTION HAZARD

Spray from the gun, hose leaks, or ruptured components can inject fluid into your body and cause extremely serious injury, including the need for amputation. Fluid splashed in the eyes or on the skin can also cause serious injury.

D

Fluid injected into the skin might look like just a cut, but it is a serious injury. Get immediate medi- cal attention.

D

Do not point the gun at anyone or at any part of the body.

D

Do not put your hand or fingers over the spray tip.

D Do not stop or deflect leaks with your hand, body, glove or rag.

D Do not “blow back” fluid; this is not an air spray system.

D Always have the tip guard and the trigger guard on the gun when spraying.

D Check the gun diffuser operation weekly. Refer to the gun manual.

D

Be sure the gun trigger safety operates before spraying.

D

Lock the gun trigger safety when you stop spraying.

D

Follow the Pressure Relief Procedure on page 10 whenever you: are instructed to relieve pressure; stop spraying; clean, check, or service the equipment; and install or clean the spray tip.

D Tighten all fluid connections before operating the equipment.

D Check the hoses, tubes, and couplings daily. Replace worn, damaged, or loose parts immediately.

Permanently coupled hoses cannot be repaired; replace the entire hose.

D Use only Graco approved hoses. Do not remove any spring guard that is used to help protect the hose from rupture caused by kinks or bends near the couplings.

MOVING PARTS HAZARD

Moving parts, such as the air motor piston, can pinch or amputate your fingers.

D

Keep clear of all moving parts when starting or operating the pump.

D Before servicing the equipment, follow the Pressure Relief Procedure on page 10 to prevent the equipment from starting unexpectedly.

4 308-693

WARNING

FIRE AND EXPLOSION HAZARD

Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and result in a fire or explosion and serious injury.

D

Ground the equipment and the object being sprayed. Refer to Grounding on page 7.

D

If there is any static sparking or you feel an electric shock while using this equipment, stop spray-

ing immediately. Do not use the equipment until you identify and correct the problem.

D

Provide fresh air ventilation to avoid the buildup of flammable fumes from solvents or the fluid being sprayed.

D Keep the spray area free of debris, including solvent, rags, and gasoline.

D Electrically disconnect all equipment in the spray area.

D Extinguish all open flames or pilot lights in the spray area.

D Do not smoke in the spray area.

D

Do not turn on or off any light switch in the spray area while operating or if fumes are present.

D

Do not operate a gasoline engine in the spray area.

TOXIC FLUID HAZARD

Hazardous fluid or toxic fumes can cause serious injury or death if splashed in the eyes or on the skin, inhaled, or swallowed.

D

Know the specific hazards of the fluid you are using.

D

Store hazardous fluid in an approved container. Dispose of hazardous fluid according to all local, state and national guidelines.

D Always wear protective eyewear, gloves, clothing and respirator as recommended by the fluid and solvent manufacturer.

308-693 5

General Information

Setup

Prepare the Site

NOTE: Reference numbers and letters in parentheses in the text refer to the callouts in the figures and the parts drawing.

NOTE: The compressed air supply to the gun must be clean and dry, to prevent damage to the finish. Use a coalescing air filter in the main air supply line.

NOTE: Always use Genuine Graco Parts and Accessories, available from your Graco distributor. Refer to

Product Data Sheet 305–813. If you supply your own accessories, be sure they are adequately sized and pressure-rated for your system.

Fig. 2 is only a guide for selecting and installing system components and accessories. Contact your Graco distributor for assistance in designing a system to suit your particular needs.

Ensure that you have an adequate compressed air supply. Refer to the performance charts on page 23 to find the air consumption of your sprayer.

Refer to Fig. 2. Bring a compressed air supply line (A) from the air compressor to the pump location. Be sure all air hoses are properly sized and pressure-rated for your system. Use only electrically conductive hoses.

The air hose should have a 3/8 npsm(m) thread.

Prepare the Operator

Install a bleed-type shutoff valve (B) in the air line to isolate the air line components for servicing. Install an air line filter (J) and a moisture trap and drain valve (C) to help remove moisture and contaminants from the compressed air supply.

All persons who operate the equipment must be trained in the safe, efficient operation of all system components as well as the proper handling of all fluids.

All operators must thoroughly read all instruction manuals, tags, and labels before operating the equipment.

Keep the site clear of any obstacles or debris that could interfere with the operator’s movement.

Have a grounded, metal pail available for use when flushing the system.

Grounding

WARNING

FIRE AND EXPLOSION HAZARD

Before operating the pump, ground the system as explained below. Also read the section FIRE OR EXPLOSION HAZ-

ARD on page 5.

Setup

Supplied Components

Refer to Fig. 2.

1.

Pump: use the ground wire and clamp (supplied).

See Fig. 1. Loosen the grounding lug locknut (W) and washer (X). Insert one end of the ground wire

(34) into the slot in lug (Z) and tighten the locknut securely. Connect the other end of the wire to a true earth ground.

Z

34

WARNING

A red-handled bleed-type master air valve (E) and a fluid drain valve (D) are supplied. These components help reduce the risk of serious injury, including fluid injection and splashing of fluid in the eyes or on the skin, and injury from moving parts if you are adjusting or repairing the pump.

The bleed-type master air valve relieves air trapped between this valve and the pump after the air is shut off. Trapped air can cause the pump to cycle unexpectedly. Locate the valve close to the pump.

The fluid drain valve assists in relieving fluid pressure in the displacement pump, hose, and gun.

Triggering the gun to relieve pressure may not be sufficient.

X

W

0720

Fig. 1

2.

Air and fluid hoses: use only electrically conductive hoses.

3.

Viscon @ Heater: refer to the heater manual, supplied.

4.

Air compressor: follow manufacturer’s recommendations.

5.

Spray gun: ground through connection to a properly grounded fluid hose and pump.

6.

Fluid supply container: follow your local code.

7.

Object being sprayed: follow your local code.

8.

Solvent pails used when flushing: follow your local code. Use only metal pails, which are conductive, placed on a grounded surface. Do not place the pail on a nonconductive surface, such as paper or cardboard, which interrupts the grounding continuity.

9.

To maintain grounding continuity when flushing or relieving pressure, hold a metal part of the spray gun firmly to the side of a grounded metal pail, then trigger the gun.

D The red-handled bleed-type master air valve (E) is required in your system to relieve air trapped between it and the air motor when the valve is closed (see the WARNING above). Be sure the bleed valve is easily accessible from the pump, and is located downstream from the pump air regulator

(F).

D

The pump air regulator (F) controls pump speed and outlet pressure by adjusting the air pressure to the pump. Locate close to the pump, but upstream from the bleed-type master air valve (E).

D

The air relief valve (41) opens automatically to prevent overpressurization of the pump.

D The gun air filter/regulator (G) adjusts the air pressure to the air-assisted airless spray gun (106).

D The air manifold (H) directs incoming air to the pump and to the gun. It includes an air inlet swivel fitting.

Continued on page 8.

308-693 7

Setup

Supplied Components (continued)

D

The fluid filter (16) includes a 60 mesh (250 micron) stainless steel element to filter particles from the fluid as it leaves the pump. It also includes the fluid drain valve (D), which is required in your system to relieve fluid pressure in the hose and gun

(see the WARNING on page 7).

D

The gun filter/swivel (104) provides a final filtering of fluid before it enters the gun, and allows greater gun maneuverability.

D

The suction hose (25) and tube (26) allow the pump to draw fluid from a 5 gallon (19 liter) pail (K).

The strainer at the end of the suction tube keeps large particles from entering the pump.

D

The back pressure regulator (40) controls back pressure to the gun and maintains proper circulation pressure.

D The 3-way valve (45) allows you to circulate fluid back to the pump or return it to the fluid container.

Fluid Heater

The fluid heater (51) heats the fluid as it passes through, to maintain the correct spraying viscosity.

Read and understand all instructions in the supplied heater manual (307–805 or 307–914) before operating the heater.

Do not put all flammable materials and debris on or near the heater. Keep the work area clean.

WARNING

FIRE, EXPLOSION, AND ELECTRIC

SHOCK HAZARD

The heater electrical cord is rated for

105

_

C (221

_

F). Do not substitute a lower temperature rated, generally available cord.

WARNING

COMPONENT RUPTURE HAZARD

Heat causes fluid to expand. If the heated fluid is trapped with nowhere to expand, it can cause component rupture.

Be sure to keep the heated fluid circulating (turn the 3-way valve to CIRC). Do not install a fluid shutoff device between the heater and the gun.

WARNING

FIRE, EXPLOSION, AND ELECTRIC

SHOCK HAZARD

The Viscon

@

Heater must be installed by a qualified electrician in compliance with all state and local codes and regulations, to reduce the risk of electric shock or other serious injury during installation or operation.

Refer to the Technical Data and to the supplied Viscon

@

Heater manual

(307–805 or 307–914) for information on heater power supply requirements.

Do not plug in or unplug the power cord in any area containing flammable fluids or fumes, to avoid fire or explosion resulting in serious injury.

Setup

KEY

SUPPLIED WITH THE SPRAYER

1 Cart

13 Pump

16 Fluid Filter (includes fluid drain valve D)

25 Suction Hose

26 Suction Tube

34 Ground Wire (required; see page 7 for installation instructions)

40 Back Pressure Regulator

41 Air Relief Valve

45 3-Way Valve

51 Fluid Heater

SUPPLIED WITH THE SPRAYER

101 Electrically Conductive, Heated Air and

Fluid Supply/Return Hose

103 Fluid Whip Hose

104 Gun Filter/Swivel

106 Air-Assisted Airless Spray Gun

D Fluid Drain Valve

E* Red-Handled Bleed-Type Master

Air Valve (required, for pump)

F* Pump Air Regulator

G* Gun Air Filter/Regulator

H* Air Manifold

* Included in Air Regulation Kit (19).

Detail of Fluid Heater

C

J

K

COMPONENTS YOU MUST SUPPLY

A

B

Electrically Conductive Air Supply Hose

Bleed-Type Master Air Valve

(for accessories)

Air Line Moisture Trap and Drain Valve

Air Line Filter

Grounded 5 Gallon (19 Liter) Pail

J

B

C

16 A

H

F

G

D 1

Detail of Air Controls

E

51

106 13

40

51 (Ref)

34

41

104

103

25

26

K

45

101

Model 231–979 Shown

06901

Fig. 2

Pressure Relief Procedure

Operation

5.

Turn the 3-way valve (45) to DRAIN. Hook the drain hose (46) onto a waste container.

WARNING

INJECTION HAZARD

The system pressure must be manually relieved to prevent the system from starting or spraying accidentally. Fluid under high pressure can be injected through the skin and cause serious injury. To reduce the risk of an injury from injection, splashing fluid, or moving parts, follow the Pressure Relief Procedure whenever you:

D are instructed to relieve the pressure,

D stop spraying,

D check or service any of the system equipment,

D or install or clean the spray tip.

6.

Unlock the gun trigger safety.

7.

Hold a metal part of the gun firmly to the side of a grounded metal pail, and trigger the gun to relieve pressure.

8.

Lock the gun trigger safety.

9.

Open the drain valve (D, required in your system), having a container ready to catch the drainage.

10. Leave the drain valve open until you are ready to spray again.

If you suspect that the spray tip or hose is completely clogged, or that pressure has not been fully relieved after following the steps above, very slowly loosen the tip guard retaining nut or hose end coupling and relieve pressure gradually, then loosen completely. Now clear the tip or hose.

WARNING

HOT SURFACE HAZARD

Do not touch the heater while it is operating. Allow the heater to cool for at least

10 minutes before flushing or servicing it.

Packing Nut

Before starting, fill the packing nut (L) 1/3 full with

Graco Throat Seal Liquid (TSL) or compatible solvent.

See Fig. 3.

WARNING

FIRE AND EXPLOSION HAZARD

Do not plug in or unplug the power cord in any area containing flammable fluids or fumes, to avoid fire or explosion resulting in serious injury.

WARNING

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the

Pressure Relief Procedure at left.

1.

Lock the gun trigger safety.

2.

Unplug the heater power cord.

3.

Circulate the fluid for at least 10 minutes to cool the heated fluid and the heater.

4.

Close the red-handled bleed-type master air valve

(E, required in your system). See Fig. 3.

The packing nut is torqued at the factory and is ready for operation. If it becomes loose and there is leaking from the throat packings, relieve pressure, then torque the nut as specified in your separate pump manual. Do this whenever necessary. Do not overtighten the packing nut.

Flush the Pump Before First Use

The pump is tested with lightweight oil, which is left in to protect the pump parts. If the fluid you are using may be contaminated by the oil, flush it out with a compatible solvent. See Flushing on page 15.

10 308-693

Operation

8.

Place the pump suction tube (26) into the fluid supply container.

CAUTION

To avoid tip-over, the cart must be on a flat and level surface. Failure to follow this caution could result in injury or equipment damage.

9.

Open the back pressure regulator (40) (fully counterclockwise).

Prime the Pump

10. Open the bleed-type air valves (B, E) and the gun air filter/regulator (G).

WARNING

FIRE AND EXPLOSION HAZARD

Do not plug in or unplug the power cord in any area containing flammable fluids or fumes, to avoid fire or explosion resulting in serious injury.

11. Hold a metal part of the gun (106) firmly to the side of a grounded metal pail and hold the trigger open.

12. Slowly open the pump air regulator (F) until the pump starts.

NOTE: To open the air regulator, turn the T-handle in

(clockwise). To close the regulator, turn the handle counterclockwise. To lock the regulator setting, tighten the jam nut.

1.

See Fig. 3. Unplug the heater power cord before priming the pump.

2.

Remove the tip guard and spray tip from the gun

(106). See the gun manual.

3.

Close the gun air filter/regulator (G), pump air regulator (F), and bleed-type air valves (B, E).

13. Cycle the pump slowly until all air is pushed out and the pump and hoses are fully primed.

14. Release the gun trigger and lock the trigger safety.

The pump will continue to cycle as long as air is supplied and the back pressure regulator is open.

4.

Close the fluid drain valve (D).

5.

Connect the air line (A) to the swivel of the air manifold (H).

6.

Check that all fittings throughout the system are tightened securely.

7.

Turn the 3-way valve (45) to CIRC. Hook the drain hose (46) onto a waste container.

15. If the pump fails to prime properly, open the drain valve (D). Use the drain valve as a priming valve until the fluid flows from the valve. Close the valve.

NOTE: When changing fluid containers with the hose and gun already primed, open the drain valve (D) to help prime the pump and vent air before it enters the hose. Close the drain valve when all air is eliminated.

308-693 11

Operation

Install the Spray Tip

WARNING

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the

Pressure Relief Procedure on page 10.

Relieve the pressure. Install the spray tip and tip guard as explained in your separate gun manual, supplied.

The fluid output and pattern width depend on the size of the spray tip, the fluid viscosity, and the fluid pressure. Use the Spray Tip Selection Chart in your gun instruction manual as a guide for selecting an appropriate spray tip for your application.

Adjust the Spray Pattern

WARNING

FIRE AND EXPLOSION HAZARD

Do not plug in or unplug the power cord in any area containing flammable fluids or fumes, to avoid fire or explosion resulting in serious injury.

1.

Start the pump. Plug in the heater power cord.

Turn the 3-way valve (45) to CIRC.

2.

Set the heater control to a trial point (4 or 5).

3.

Circulate fluid through the pump for at least 10 minutes, at very low pressure. Check the temperature on the heater thermometer.

4.

Adjust the fluid pressure and temperature to the lowest settings necessary to get the desired results. Use the air regulator (F) to adjust the pump speed and fluid pressure until the spray is completely atomized. Refer to the back pressure valve and heater manuals (supplied) for adjustment procedures. Higher pressures and temperatures may not improve the spray pattern and will cause premature component wear.

WARNING

COMPONENT RUPTURE HAZARD

To reduce the risk of overpressurizing your package, which could cause component rupture and serious injury, never exceed 100 psi (0.7 MPa, 7 bar) air input pressure to the package. Never exceed 100 psi (0.7 MPa, 7 bar) air input pressure to the spray gun. Also refer to the Technical Data on page 22 and to your separate component manuals.

Heat causes fluid to expand. If the heated fluid is trapped with nowhere to expand, it can cause component rupture. Be sure to keep the heated fluid circulating (turn the 3-way valve to CIRC). Do

not install a fluid shutoff device between the heater and the gun.

5.

When applying the fluid, keep the gun a consistent distance, about 8 to 12 inches (200 to 300 mm) from the surface of the object being sprayed.

Always hold the gun at a right angle from the surface. Do not make an arc with the gun as it causes an uneven coat of fluid. Use a full-open, full-close triggering action. Practice to find the best length and speed of stroke.

6.

To adjust the spray pattern, follow the instructions in your gun manual, supplied.

7.

With the pump and lines primed, and with adequate volume supplied, the pump will continue to cycle as long as air is supplied and the back pressure regulator is open.

CAUTION

Do not allow the pump to run dry. It will quickly accelerate to a high speed, causing damage. If your pump is running too fast, stop it immediately and check the fluid supply. If the container is empty and air has been pumped into the lines, refill the container and prime the pump and the lines, or flush and leave it filled with a compatible solvent. Eliminate all air from the fluid system.

12 308-693

Operation

KEY

16 Fluid Filter (includes fluid drain valve D)

25 Suction Hose

26 Suction Tube

40 Back Pressure Regulator

45 3-Way Valve

46 Fluid Return Drain Hose

51 Fluid Heater

101 Electrically Conductive, Heated Air and

Fluid Supply/Return Hose

103 Fluid Whip Hose

104 Gun Filter/Swivel

106 Air-Assisted Airless Spray Gun

A Electrically Conductive Air Supply Hose

B

D

Bleed-Type Master Air Valve

(for accessories)

Fluid Drain Valve

E

F

G

H

K

L

Red-Handled Bleed-Type Master

Air Valve (required, for pump)

Pump Air Regulator

Gun Air Filter/Regulator

Air Manifold

Grounded 5 Gallon (19 Liter) Pail

Packing Nut/Wet-Cup (partially hidden)

1 Torque as specified in your separate pump manual.

B

Detail of Fluid Heater

A

16

H

F

G

Detail of Air Controls

D

E

51

106

40

51 (Ref)

104

103

25

26

K

1

L

101

46

45

Model 231–979 Shown

Fig. 3

06901

308-693 13

Operation

Shutdown and Care of the Pump Clean the In-Line Filter/Swivel Element

The filter/swivel (104) includes a 100 mesh stainless steel filter element (105). Clean the element periodically with a compatible solvent, as follows.

WARNING

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the

Pressure Relief Procedure on page 10.

WARNING

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the

Pressure Relief Procedure on page 10.

1.

Relieve the pressure.

2.

Disassemble the filter/swivel (104) and remove the filter element (105).

3.

Clean or replace the element, as necessary.

4.

Reassemble. Torque the two halves of the filter/ swivel to 10–15 ft-lb (14–20 N S m).

For overnight shutdown, stop the pump at the bottom of its stroke to prevent fluid from drying on the exposed displacement rod and damaging the throat packings. Relieve the pressure.

Always flush the pump before the fluid dries on the displacement rod. See Flushing on page 15.

14 308-693

Operation

Flushing

WARNING

FIRE AND EXPLOSION HAZARD

Before flushing, read the section FIRE

OR EXPLOSION HAZARD on page 5.

Be sure the entire system and flushing pails are properly grounded. Refer to

Grounding on page 7.

Flush the pump:

D Before the first use

D When changing colors or fluids

D Before fluid can dry or settle out in a dormant pump

(check the pot life of catalyzed fluids)

D

Before storing the pump.

Flush with a fluid that is compatible with the fluid you are pumping and with the wetted parts in your system.

Check with your fluid manufacturer or supplier for recommended flushing fluids and flushing frequency.

CAUTION

If you have a carbon steel package, never leave water or water-base fluid in the pump overnight. If you are pumping water-base fluid, flush with water first, then with a rust inhibitor such as mineral spirits.

Relieve the pressure, but leave the rust inhibitor in the pump to protect the parts from corrosion.

WARNING

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the

Pressure Relief Procedure on page 10.

WARNING

HOT SURFACE HAZARD

Do not touch the heater while it is operating. Allow the heater to cool for at least

10 minutes before flushing or servicing it.

WARNING

FIRE AND EXPLOSION HAZARD

Do not plug in or unplug the power cord in any area containing flammable fluids or fumes, to avoid fire or explosion resulting in serious injury.

1.

Unplug the heater power cord and circulate the fluid for at least 10 minutes to cool the heated fluid and the heater.

2.

Relieve the pressure.

3.

Remove the tip guard and spray tip from the gun.

See the gun manual.

4.

Remove the filter element from the fluid filter (16).

Reinstall the filter bowl.

5.

Open the back pressure regulator (40). Set the

3-way valve (45) to CIRC.

6.

Place the suction tube (26) in a container of solvent.

7.

Hold a metal part of the gun firmly to the side of a grounded metal pail.

8.

Start the pump. Always use the lowest possible fluid pressure when flushing.

9.

Trigger the gun. Flush the system until clear solvent flows from the gun.

10. Release the gun trigger and lock the trigger safety.

The pump will continue to cycle as long as air is supplied and the back pressure regulator is open.

11. Set the 3-way valve (45) to DRAIN. Hook the drain hose (46) onto a waste container and continue flushing until clear fluid comes from the hose.

12. Relieve the pressure.

13. Clean the tip guard, spray tip, and fluid filter element separately, then reinstall them.

14. Clean the inside and outside of the suction tube

(26).

308-693 15

Parts

55

53

104

103

D F

C

54

16

17

15

101 (Ref)

47

15

40

32

101 (Ref)

52

D

35

36

37

51 (Ref)

7 Y

15

48

(Ref)

E

35

106

4

2

B

50 (Ref)

101 (Ref)

13

39

101

102

110

111

102

49

F

51

19

41

21

C

46

43

6

5

18

14

50

E

B

45 47

27

28

12

11

48

B

A

26

50 (Ref)

8

20

24 (Ref)

25

9

10

3

1

38

42

24

A

34

06899

16 308-693

Parts

NOTE: Part numbers vary by package. To find the part number used in your package, read down the chart to find the desired ref. no., then read left to right to find the part number for your package.

Packages

Ref.

No.

Description

CST

231–979,

231–980,

231–982

SST

232–034,

232–035,

232–037

CST

232–005,

232–006,

232–008

CST

232–015,

232–016,

232–018

SST

232–049,

232–050,

232–052

CST

232–059,

232–060

Qty

9

10

11

1

2

3

CART, portable; includes replaceable items

2–10

. BRACKET, front

. CAP

4 . CAPSCREW, hex hd; M8 x 1.25;

16 mm (5/8 in.)

. NUT, keps, hex; M8 5

6 . WASHER, flat; 8 mm

7 Y . LABEL, warning

8 . WHEEL

. RING, retaining

. HUBCAP

12

13

14

15

CAPSCREW, hex hd;

1/4–20 x 5/8 in. (16 mm)

CAPSCREW, hex hd;

1/4–20 x 3/4 in. (19 mm)

LOCKWASHER, spring; 1/4 in.

PUMP, 30:1 President; cst; see manual 306–981

PUMP, 30:1 President; sst; see manual 308–106

PUMP, 15:1 Monark; sst; see manual 308–106

PUMP, 15:1 President; cst; see manual 306–936

PUMP, 23:1 Monark; sst; see manual 307–619

PUMP, 23:1 Monark; cst; see manual 307–619

UNION, swivel, 90 _ ; cst;

3/8 npt(f) x 1/2 npsm(f)

UNION, swivel, 90 _ ; sst; 1/2 npt(fbe)

NIPPLE; cst; 1/4 npt x 1/4 npsm

16

17

18

238–938

191–902

107–310

108–768

113–761

108–788

290–331

106–062

101–242

104–811

100–270

100–016

223–586

159–801

UNION, swivel; sst; 3/8 npt(m) x 3/8 npsm(f)

NIPPLE; cst; 3/8 npt

NIPPLE; sst; 3/8 npt x 1/2 npt

NIPPLE; cst; 3/8 npt x 1/2 npt

162–453

NIPPLE; sst; 1/4 npt x 1/4 npsm

FLUID FILTER; cst; see manual 307–273

FLUID FILTER; sst; see manual 307–273

239–244

UNION, swivel; cst; 3/8 npt(m) x 3/8 npsm(f) 155–665

156–850

238–938

191–902

107–310

108–768

113–761

108–788

290–331

106–062

101–242

104–811

100–270

100–016

223–843

113–934

166–846

239–300

235–207

112–027

238–938

191–902

107–310

108–768

113–761

108–788

290–331

106–062

101–242

104–811

100–022

100–016

223–844

159–801

162–453

239–244

155–665

156–850

238–938

191–902

107–310

108–768

113–761

108–788

290–331

106–062

101–242

104–811

100–270

100–016

217–580

159–801

162–453

239–244

155–665

188–577

238–938

191–902

107–310

108–768

113–761

108–788

290–331

106–062

101–242

104–811

100–022

100–016

237–958

113–934

166–846

239–300

235–207

112–027

238–938

191–902

107–310

108–768

113–761

108–788

290–331

106–062

101–242

104–811

100–022

100–016

223–596

159–801

162–453

239–244

155–665

1

1

2

2

2

2

1

2

2

2

2

2

2

1

1

1

1

1

1

1

1

3

3

1

1

1

1

156–850 1

1

1

Y Replacement Danger and Warning labels, tags and cards are available at no cost.

This label is also available in the following languages:

German (Part No. 290–396)

French (Part No. 290–397)

Spanish (Part No. 290–398).

Parts

NOTE: Part numbers vary by package. To find the part number used in your package, read down the chart to find the desired ref. no., then read left to right to find the part number for your package.

Packages

41

42

43

38

39

40

34

35

36

37

Ref.

No.

Description

19

20

21

24

25

26

27

28

32

33

44

CST

231–979,

231–980,

231–982

SST

232–034,

232–035,

232–037

CST

232–005,

232–006,

232–008

CST

232–015,

232–016,

232–018

SST

232–049,

232–050,

232–052

CST

232–059,

232–060

Qty

AIR REGULATOR KIT; see manual 308–686

238–939 238–939

UNION, swivel; cst; 1/2 npt(m) x 3/8 npsm(f) 158–256 158–256

238–939 238–939

158–256

238–939 238–939 1

1

UNION, swivel; cst; 3/8 npt(m) x 3/8 npsm(f)

TEE; 3/8 npt(f) run x 3/8 npt(m) branch 113–777 113–777

155–665

113–777 113–777

155–665

113–777

155–665

113–777

1

1

HOSE, air; 3/8 in. (10 mm) ID; 3/8 npt(mbe);

22 in. (559 mm) long

HOSE, suction; 3/4 in. (19 mm) ID;

3/4 npt (mbe) cst fittings; 3.5 ft (1 m) long tHOSE, suction; 3/4 in. (19 mm) ID;

3/4 npt (mbe) sst fittings; 3.5 ft (1 m) long

TUBE, suction; aluminum

TUBE, suction; sst

239–061 239–061 239–061 239–061 239–061 239–061 1

214–960

192–121

236–075

112–191

214–960

192–121

166–998

214–960

192–121

166–998

236–075

112–191

214–960

192–121

1

1

1

1

166–998 1 MANIFOLD, inlet; cst;

1/4 npt(f) x 3/4 npt(f) x 3/4 npsm(f)

MANIFOLD, inlet; sst;

1/4 npt(f) x 3/4 npt(f) x 3/4 npsm(f)

166–998

UNION, swivel; cst; 3/4 npt(m) x 3/4 npsm(f) 157–785

UNION, swivel; sst; 3/4 npt(m) x 3/4 npsm(f)

HOSE, fluid; nylon;1/4 in. (6 mm) ID;

1/4 npt(m) x 1/4 npsm(f);

10 in. (0.25 m) long; cst fittings

239–368

113–927

112–268

157–785

239–368

157–785

239–368

113–927

112–268

157–785

239–368

1

1

1

1

HOSE, fluid; nylon;1/4 in. (6 mm) ID;

1/4 npt(m) x 1/4 npsm(f);

10 in. (0.25 m) long; sst fittings

THROAT SEAL LIQUID; 1 pint (0.5 liter); not shown

206–994

239–373

206–994 206–994 206–994

239–373

206–994 206–994

1

1

GROUND WIRE AND CLAMP

INSULATOR, heat

238–909

167–002

238–909

167–002

238–909

167–002

238–909

167–002

238–909

167–002

238–909

167–002

1

4

WASHER; 1/4 in.

100–527 100–527 100–527 100–527 100–527 100–527 2

SCREW, hex hd; 1/4–20 x 7/8 in. (22 mm) 102–254 102–254 102–254 102–254 102–254 102–254 2

SCREW, socket; M5 x 0.8; 16 mm (5/8 in.) 113–768 113–768 113–768 113–768 113–768 113–768 6

NUT, hex, self-locking; M5 x 0.8

105–332 105–332 105–332 105–332 105–332 105–332 6

REGULATOR, back pressure; cst; see manual 306–860

REGULATOR, back pressure; sst; see manual 306–860

206–819

238–926

206–819 206–819

238–926

206–819 1

1

VALVE, relief; 125 psi (0.86 MPa, 8.6 bar) 113–769 113–769 113–769 113–769 113–769 113–769 1

UNION, swivel, 90

_

; 3/8 npt(m) x 3/8 npt(f) 155–494 155–494 155–494 155–494 155–494 155–494 1

STRAINER, suction tube; 1/2 npt(f); sst 187–146 187–146 187–146 187–146 1

STRAINER, suction tube; 3/4 npt(f); sst

NUT, hex; 1/4–20; not shown

187–190

100–015

187–190

100–015 100–015

1

2

18 308-693

Parts

NOTE: Part numbers vary by package. To find the part number used in your package, read down the chart to find the desired ref. no., then read left to right to find the part number for your package.

Packages

Ref.

No.

Description

45

46

47

48

VALVE, 3-way; 1/4 npt(m); cst

VALVE, 3-way; 1/4 npt(m); sst

HOSE, drain; nylon; cst fittings;

1/4 in. (6 mm) ID; 1/4 npsm(f)

HOSE, drain; nylon; sst fittings;

1/4 in. (6 mm) ID; 1/4 npsm(f)

ELBOW; 1/4 npt (m x f); cst

ELBOW; 1/4 npt (m x f); sst

HOSE, fluid; nylon; cst fittings;

0.15 in. (4 mm) ID; 1/4 npsm (fbe);

14 in. (0.36 m) long

HOSE, fluid; nylon; cst fittings;

0.15 in. (4 mm) ID; 1/4 npsm (fbe);

16 in. (0.41 m) long

49

50

HOSE, fluid; nylon; sst fittings;

0.15 in. (4 mm) ID; 1/4 npsm (fbe);

14 in. (0.36 m) long

ELBOW, 90 _ ; cst; 1/2 npt (m x f)

ELBOW, 90

_

; sst; 1/2 npt (m x f)

HOSE, fluid; nylon; cst fittings;

1/2 in. (13 mm) ID; 1/2 npt (mbe);

19.5 in. (0.5 m) long

HOSE, fluid; nylon; sst fittings;

1/2 in. (13 mm) ID; 1/2 npt (mbe);

19.5 in. (0.5 m) long

CST

231–979,

231–980,

231–982

SST

232–034,

232–035,

232–037

214–711

206–965

113–834

CST

232–005,

232–006,

232–008

CST

232–015,

232–016,

232–018

SST

232–049,

232–050,

232–052

214–711

206–965

214–711

206–965

113–834

CST

232–059,

232–060

Qty

214–711 1

1

206–965 1

100–840

239–378

158–683

239–148

239–062

166–866

239–109

166–242

239–153

100–840 100–840

239–378

239–379

158–683 158–683

239–148 239–148

239–062

166–866

239–109

166–242

239–153

1

100–840 2

2

239–378 1

1

1

158–683 1

1

239–148 1

1

308-693 19

Hose and Gun Parts

Packages

Ref.

No.

Description

CST

231–979,

231–980,

231–982

SST

232–034,

232–035,

232–037

CST

232–005,

232–006,

232–008

CST

232–015,

232–016,

232–018

SST

232–049,

232–050,

232–052

CST

232–059,

232–060

Qty

101 HOSE, air/fluid, triple; nylon;

1/4 in. (6 mm) ID; 1/4 npsm (fbe) cst fittings;

24.6 ft (7.5 m) long;

HOSE, air/fluid, triple; nylon;

1/4 in. (6 mm) ID; 1/4 npsm (fbe) sst fittings;

24.6 ft (7.5 m) long

102 NIPPLE; 1/4 npsm x 1/8 npt; cst

NIPPLE; 1/4 npsm x 1/8 npt; sst

103 HOSE, whip, fluid; nylon; 3/16 in. (5 mm) ID;

1/4 npsm (fbe) cst fittings;

23.6 in. (0.6 m) long

HOSE, whip, fluid; nylon; 3/16 in. (5 mm) ID;

1/4 npsm (fbe) sst fittings;

23.6 in. (0.6 m) long

104 SWIVEL FILTER, in-line; includes replaceable item 105

105 . ELEMENT, filter; 100 mesh sst; not shown

239–346

191–872

238–708

239–394

205–264

239–310

191–929

239–069

239–394

205–264

239–346

191–872

238–708

239–394

205–264

239–346

191–872

238–708

239–394

205–264

239–310

191–929

239–069

239–394

205–264

239–346

191–872

238–708

239–394

205–264

1

1

3

3

1

1

1

1

106 AIR-ASSISTED AIRLESS SPRAY GUN; see manual 308–640

238–402 238–402 238–402 238–402 238–402 238–402 1

107 SPRAY TIP; customer’s choice; not shown GG4–xxx GG4–xxx GG4–xxx GG4–xxx GG4–xxx GG4–xxx 1

110 MANIFOLD, hose; cst; 1/8 npt(f)

MANIFOLD, hose; sst; 1/8 npt(f)

169–795

191–923

169–795 169–795

191–923

169–795 1

1

111 PLUG; cst; 1/8 npt

PLUG; sst; 1/8 npt

100–139

107–570

100–139 100–139

107–570

100–139 1

1

Heater Parts

NOTE: This chart includes the heater and related parts which vary by package. The packages are grouped by heater voltage, so they are in different columns from the preceding charts. To find the part number used in your package, read down the chart to find the desired ref. no., then read left to right to find the correct part number.

Ref.

No.

Description

120V PACKAGES:

231–979, 232–005,

232–015, 232–034,

232–049, 232–059

51

52

HEATER, fluid, 120V; see manual 307–805 220–522

HEATER, fluid, 240V; see manual 307–805

HEATER, fluid, 220V; see manual 307–914

CORD, electrical; with plug; 12 AWG; 600V;

20 AMP; 221

_

F (105

_

C); 6.5 ft (2 m) long

CORD electrical; without plug; 12 AWG;

600V; 20 AMP; 221 _ F (105 _ C);

6.5 ft (2 m) long

110–160

53

54

55

BUSHING; 3/4 npt(m) x 1/2 npt(f)

STRAIN RELIEF, 90 _

STRAIN RELIEF, clamp

ELBOW, conduit, 45 _ ; 3/4 npt (m x f)

107–219

112–408

113–778 z

These 220V packages are only available in Europe.

Packages

240V PACKAGES:

231–980, 232–006,

232–016, 232–035,

232–050, 232–060

220–523

110–160

107–219

112–408

113–778

220V PACKAGES:

231–982, 232–008,

232–018, 232–037,

232–052 z

222–307

113–922 not used

113–162

113–778

Qty

1

1

1

1

1

1

1

1

1

Shown without hoses and gun

Dimensions

A B

38.5 in.

(978 mm)

22.5 in.

(572 mm)

All Packages

C

21 in.

(534 mm)

Width

Across

Wheels

20 in.

(508 mm)

Weight

145 lb

(66 kg)

A

B

C

06898

308-693 21

Technical Data

Category

Maximum fluid working pressure

Data

Part Nos. 231–979, 231–980, 231–982, 232–034, 232–035, 232–037: 3000 psi (21 MPa, 210 bar)

Part Nos. 232–049, 232–050, 232–052, 232–059, 232–060: 2300 psi (16 MPa, 160 bar)

Part Nos. 232–015, 232–016, 232–018: 1500 psi (10 MPa, 100 bar)

Part No. 232–005, 232–006, 232–008: 1500 psi (10 MPa, 100 bar)

100 psi (0.7 MPa, 7 bar) Maximum air input pressure

Maximum gun air input pressure

Ratio

100 psi (0.7 MPa, 7 bar)

Maximum

Heater

Voltage and

Amperage

Maximum operating temperature

Part Nos. 231–979, 231–980, 231–982, 232–034, 232–035, 232–037: 30:1

Part Nos. 232–049, 232–050, 232–052, 232–059, 232–060: 23:1

Part Nos. 232–015, 232–016, 232–018: 15:1

Part No. 232–005, 232–006, 232–008: 15:1

Part Nos. 231–979, 232–005, 232–015, 232–034, 232–049, 232–059: 120V, 16.7 Amp

Part Nos. 231–980, 232–006, 232–016, 232–035, 232–050, 232–060: 240V, 9.6 Amp z Part Nos. 231–982, 232–008, 232–018, 232–037, 232–052: 220V, 9.6 Amp

180 _ F (82 _ C)

Wetted parts Pump: See applicable pump manual

Spray Gun: See gun manual 308–640

Fluid Filter: See filter manual 307–273

Fluid Hoses: Nylon z

These 220V packages are only available in Europe.

Air Motor

President

Monark

Air Motor

President

Monark

Sound Pressure Levels (dBa)

(measured at 1 meter from unit)

40 psi (0.28 MPa, 2.8 bar)

Input Air Pressures at 15 cycles per minute

70 psi (0.48 MPa, 4.8 bar) 100 psi (0.7 MPa, 7 bar)

73.6 dB(A)

73.25 dB(A)

78.34 dB(A)

75.85 dB(A)

80.85 dB(A)

77.65 dB(A)

Sound Power Levels (dBa)

(tested in accordance with ISO 9614–2)

40 psi (0.28 MPa, 2.8 bar)

Input Air Pressures at 15 cycles per minute

70 psi (0.48 MPa, 4.8 bar) 100 psi (0.7 MPa, 7 bar)

87.4 dB(A)

87.0 dB(A)

92.09 dB(A)

89.65 dB(A)

94.62 dB(A)

91.43 dB(A)

Technical Data

Performance Charts

To find Fluid Outlet Pressure (psi/MPa/bar) at a specific fluid flow

(lpm/gpm) and operating air pressure (psi/MPa/bar):

1.

Locate desired flow along bottom of chart.

2.

Follow vertical line up to intersection with selected fluid outlet pressure curve (black). Follow left to scale to read fluid outlet pressure.

To find Pump Air Consumption (m

#

/min or scfm) at a specific fluid flow (lpm/gpm) and air pressure (psi/MPa/bar):

1.

Locate desired flow along bottom of chart.

2.

Read vertical line up to intersection with selected air consumption curve (gray). Follow right to scale to read air consumption.

KEY: Fluid Outlet Pressure – Black Curves

Air Consumption – Gray Curves

A 100 psi (0.7 MPa, 7 bar) air pressure

B 70 psi (0.49 MPa, 4.9 bar) air pressure

C 40 psi (0.28 MPa, 2.8 bar) air pressure psi

MPa, bar

3000

21, 210

2250

15.8, 158

A

13

PRESIDENT 30:1 cycles per minute

26 39 52 60 63 scfm m

#

/min

40

1.12

B

30

0.84

1500

10.4,104

A

20

0.56

C B

750

5.1, 51

10

0.28

C gpm liters/minute

0

0.0

0.2

0.8

0.4

1.5

0.6

2.3

0.8

3.0

1.0

3.8

FLUID FLOW (TEST FLUID: NO. 10 WEIGHT OIL) psi

MPa, bar

3000

21, 210

2250

15.8, 158

A

15

MONARK 23:1 cycles per minute

30 45 60 75 scfm m

#

/min

15

0.42

1500

10.4,104 B

10

0.28

750

5.1, 51 C

A

5

0.14

gpm liters/minute

0

0.0

0.1

0.4

0.2

0.8

B

0.3

1.2

C

0.4

1.5

0.5

1.9

FLUID FLOW (TEST FLUID: NO. 10 WEIGHT OIL) psi

MPa, bar

1500

10.4, 104

1250

8.7, 87

1000

7, 70

750

5.1, 51

500

3.4, 34

250

1.7, 17 gpm

0

0.0

liters/minute

A

B

C

18

0.5

1.9

PRESIDENT 15:1 cycles per minute

35 51

1.0

3.8

A

C

1.5

5.7

B

60 66

2.0

7.6

scfm m

#

/min

50

1.40

40

1.12

30

0.84

20

0.56

10

0.28

FLUID FLOW (TEST FLUID: NO. 10 WEIGHT OIL) psi

MPa, bar

1500

10.4, 104

1250

8.7, 87

1000

7, 70

750

5.1, 51

500

3.4, 34

250

1.7, 17 gpm

0

0.0

liters/minute

A

B

C

19

MONARK 15:1 cycles per minute

37 54 60

A

71

B

C

88 scfm m # /min

25

0.70

20

0.56

15

0.42

10

0.28

5

0.14

0.2

0.8

0.4

1.5

0.6

2.3

0.8

3.0

1.0

3.8

FLUID FLOW (TEST FLUID: NO. 10 WEIGHT OIL)

308-693 23

Graco Warranty and Limitation of Liability

WARRANTY

Graco warrants all equipment listed in this manual which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale by an authorized Graco distributor to the original purchaser for use. Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations.

This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.

This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.

THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING

BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PUR-

POSE.

Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two

(2) years of the date of sale.

GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS

FOR A PARTICULAR PURPOSE IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS, OR COMPONENTS

SOLD BUT NOT MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.) are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.

For Sales to Canadian Customers:

Except as expressly stated herein, Graco makes no representations, warranties or conditions, express, implied or collateral, concerning any goods or services sold, and GRACO SHALL NOT BE LIABLE IN ANY MANNER FOR any other representation, warranty or condition of any kind, whether arising by operation of law or otherwise, including but not limited to, WARRANTIES OF

MERCHANTABLE QUALITY OR FITNESS FOR A PARTICULAR PURPOSE.

LIMITATION OF LIABILITY

In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or for the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.

Graco Phone Number

TO PLACE AN ORDER, contact your Graco distributor, or call this number to identify the distributor closest to you:

1–800–367–4023 Toll Free

All written and visual data contained in this document reflects the latest product information available at the time of publication.

Graco reserves the right to make changes at any time without notice.

Sales Offices: Atlanta, Detroit, Los Angeles

Foreign Offices: Belgium, Canada, England, Korea, Switzerland, France, Germany, Hong Kong, Japan

GRACO INC.

P.O. BOX 1441 MINNEAPOLIS, MN 55440–1441

PRINTED IN U.S.A. 308–693 January 1997

24 308-693

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement