Annex 1A7 for the User manual Fans | Air Handling Units | Fire Safety | Air Distribution Products | Air Curtains and Heating Products | Tunnel fans Annex 17 for the User Manual Systemair E28 Controller Version 3.2 and 3.3 Operator's Guide Danvent DV and TIME Callender and temperature settings LEDs and buttons – navigating the menus – (change parameters) ..........2 Operator's level - tree structure .....................................................................3 Running mode – Auto/On/Off .........................................................................3 Alarm – cancel, acknowledge .........................................................................4 Setting of temperature.....................................................................................5 Modification of outdoor compensated supply temperature......................5 Setting of flows - Flow control .......................................................................6 Setting of flows - Pressure control ................................................................7 Schedule settings ..............................................................................................8 Calender settings (time, date, weekday) ......................................................8 Setting of holidays ............................................................................................9 Setting of extended running ...........................................................................9 Setting of min/max supply air temperature ............................................. 10 Restore Systemair factory settings or latest user parameters and settings..................................................................................................... 11 LEDs and buttons – navigating the menus – (change parameters) Hand terminal – Systemair Control Panel UP: Move to a higher menu line (Increase value of the parameter) DOWN: Move to a lower menu line (Decrease value of the parameter) RIGHT: Move right to a lower menu level (Move the curser to the right in the parameter) LEFT: Move left to a higher menu level. (Move the curser to the left in the parameter) OK/ENTER: Open/activate a selected menu/setting (Confirm a parameter value) LED's and buttons ALARM: Press for alarm list CLEAR: Abort a parameter setting and restore the original value, if ”OK/ENTER” not yet has been pressed. ALARM LED: Red light is flashing for unacknowledged alarm. Permanent red light for acknowledged alarm, but the alarm is still active, because the reason is not yet eliminated. "WRITE ENABLE" LED: Yellow light – slow flashing indicates that a parameter can be selected for changes, when the OK/ENTER button is pressed. Yellow light – fast flashing indicates that the parameter is activated for changes. Permanent yellow light indicates that the changes are going on. The menus are organised in a horizontal tree structure – upper left corner is start 2 Operator's level - tree structure Start display Danvent DV and TIME Date - running mode Start menus Running mode On / Off / Auto Running mode Selected functions and actual values Temperature Code - Setpoint Air control Code - Supply air m3/h or Pa Possibly CO2control Code - Extract air m3/h or Pa Time settings Set time and date Scedules Start / Stop Extended running Access rights Change level Code - 1111 Running mode – Auto/On/Off Follow the steps below The display shows x1 The display is lit up 2. x1 Running mode x2 Actual running mode 3. Running mode Auto Manuel reduced run Manuel normal run Off 1. Danvent DV TIME Date, time Syst: Running mode (Auto, Manual reduced, Man. norm., Off) 4. To select Auto, Manual Normal, Manual Reduced or Off 5. 6. Confirm selected value with OK. The system will automatically return to the start menu after some minutes. To return to the start menu at once – press and several times 3 Alarm – cancel, acknowledge 3. 4. 5. 6. 7. 4 Example: Low frost guard temp Acknowledge Block Cancel 2. Example: Low frost guard temp Date, time, Class:A Select – Cancel. Never select Block, Block is only for test purposes during maintenance work. Confirm with OK. Class A alarm is always triggered by the system, when the reason for alarm is hazardous, and it is only possible to restart the unit, when the reason for the alarm has been solved. The Class A alarm can be triggered by the temperature sensor inside the water heating coil if the temperature falls below the set point value, or the class A alarm can be triggered by the fire thermostats when the temperature rises above the set point values, indicating risk of fire. When the reason for the alarm has been solved, pressing the OK button will activate the menu - Confirm - and the unit starts. The alarm indication disappears from the display. Confirm selected value with OK. The system will automatically return to the start menu after some minutes. To return to the start menu at once several times – press and Example: Low frost guard temp Date, time, Class:A Cancel x2 Press the alarm button twice to see the alarms logged in the alarm list 1. The display shows Follow the steps below Setting of temperature Follow the steps below The display shows x1 The display is lit up 2. x1 Temperature x1 The system is configured to control a certain temperature. The actual value and set point for this temperature is shown. Access code 1111 may be necessary. 4. Value to be changed flashes. Act: xx.x ˚C Setp: yy.y ˚C Setp: yy.y ˚C Select and confirm new set point temperature. The system will automatically return to the start menu after some minutes. 5. Setp 3. 1. Danvent DV TIME Date, time Syst: Running mode (Auto, Manual reduced, Man. norm., Off) To return to the start menu at once several times. – press and 6. Modification of outdoor compensated supply temperature x2 3. x1 4. 5. 6. Outdoor comp Setp. xx ˚C = zz.z ˚C yy ˚C = vv.v ˚C Set point temperatures for outdoor temperature compensation are shown. The control Outdoor comp. Setp curve is defined with 8 node points. Only 2 or xx ˚C = zz.z. ˚C yy ˚C = vv.v ˚C 3 node points are shown in the display, and the remaining node points are displayed by scrolling and . 2. Temperatur x2 1. Value to be changed flashes. Select one new set point temperature for each outdoor temperature shown on the curve and confirm selected value with OK.The system will automatically return to the start menu after some minutes. To return to the start menu at once – press and several times. 5 Setting of flows - Flow control Follow the steps below The display shows x1 The display is lit up 2. x3 Air control 3. x1 Flow control (control of the flow through the fans) 1. Danvent DV TIME Date, time Syst: Running mode (Auto, Manual reduced, Man. norm., Off) Selection of supply air fan (SAF) or exhaust air fan (EAF). 4. 5. x2 6 Supply air fan selected as example. Value to be changed flashes. Change of set point for normal flow (1/1) and for reduced flow (1/2). Access code 1111 may be necessary. 6. 7. Confirm change of the set point value with OK. Value to change is flashing. 8. Select and confirm new value for normal air flow (1/1) and for reduced air flow (1/2) 9. Confirm selected value with OK 10. SAF (SAF = Supply air fan) EAF (EAF = Extract air fan) x1 Outdoor compensation of the airflow is able to reduce the air flow when the outdoor temperature is low. Two node points - outdoor temperature/airflow defines the reduction of airflow by declining outdoor temperature. The temperature compensation between the 2 node points is linear. 11. Confirm change of the set point value with OK. Value to change is flashing. 12. To return to the start menu at once – press and several times. Flow control SAF Setp. 1/1: xx.xxx m³/h Setp. 1/2: yy.yyy m³ /h Setp. 1/1: x.xxx m³/h Setp. 1/2: y.yyy m³/h Setp. 1/1: xx.xxx Setp. 1/2: yy.yyy Outdoor comp. setp aa ˚C = bb.bbb m3/h cc ˚C = dd.ddd m3/h Setting of flows - Pressure control Follow the steps below The display shows x1 The display is lit up 2. x3 Air control 1. Danvent DV TIME Date, time Syst: Running mode (Auto, Manual reduced, Man. norm., Off) 3. x1 Selection of supply air fan (SAF) or exhaust air fan (EAF). 4. 5. x2 Supply air fan selected as example. Value to be changed flashes. Change of set point for normal flow (1/1) and for reduced flow (1/2). Access code 1111 may be necessary. 6. 7. Confirm change of the set point value with OK. Value to change is flashing. 8. Select and confirm new value for normal air flow (1/1) and for reduced air flow (1/2) 9. Confirm selected value with OK 10. 7 Pressure control Pressure control SAF (SAF = supply air fan) EAF (EAF = extract air fan) x1 Outdoor compensation of the airflow is able to reduce the air flow when the outdoor temperature is low. Two node points - outdoor temperature/pressure in ducts defines the reduction of airflow by declining outdoor temperature. The temperature compensation between the 2 node points is linear. 11. Confirm change of the set point value with OK. Value to change is flashing. 12. To return to the start menu at once – press and several times. Pressure control SAF Setp. 1/1: xxx Pa Setp. 1/2: yyy Pa Setp. 1/1: xxx Pa Setp. 1/2: yyy Pa Setp. 1/1: xxx Setp. 1/2: yyy Outdoor comp. setp aa ˚C = bbb Pa cc ˚C = ddd Pa Schedule settings Follow the steps below The display shows x1 The display is lit up 2. x4 Time settings 3. x1 1. 4. 5. Danvent DV TIME Date, time Syst: Running mode (Auto, Manual reduced, Man. norm., Off) x1 Time/Date Timer Normal Speed Timer Reduced Speed Extended running Holidays Select Timer Normal speed (example). (Do not select Time/Date, because this is the Calendar setting – time, date, weekday of the internal clock in the controller) Normal Speed Monday Per 1: 09:00 - 16:00 (Periode 1) Per 2: 16:00 - 21:00 (Periode 2) 6. Confirm selected value with OK. Value to be changed flashes. 7. Return to menu to select: Timer Normal Speed or Timer Reduced Speed and so on. 8. Confirm selected value with OK. The system will automatically return to the start menu after some minutes. Monday Per 1: 07:00 - 1700 (Periode 1) Per 2: 17:00 - 07:00 (Periode 2) Calender settings (time, date, weekday) x1 The display is lit up 2. x4 Time settings 3. x1 Danvent DV TIME Date, time Syst: Running mode (Auto, Manual reduced, Man. norm., Off) 1. Time/Date Timer Normal Speed Timer Reduced Speed Extended running Holidays 4. Select Time/Date (this menu permits the setting of time and date in the internal clock) 5. Time: aa:aa is activated for changes. Value to be changed flashes 6. To select the correct value. 7. Confirm with OK. 8. Confirm with OK when all values are OK. The system will automatically return to the start menu after some minutes.. 9. To return to the start menu at once – press and several times. Time: aa:aa Date: bbbb-bb-bb Weekday: Xxxxxxxxx 8 Setting of holidays The display shows 1. x1 The display is lit up 2. x4 Time settings 3. x1 4. x4 5. x1 Select Holidays (Do not select Time/Date, because this is for setting the internal clock) 6. Confirm selected value (example). Value to be changed flashes. 7. Confirm with OK when all values are OK. The system will automatically return to the start menu after some minutes 8. Danvent DV TIME Date, time Syst: Running mode (Auto, Manual reduced, Man. norm., Off) Follow the steps below Time/Date Timer Normal Speed Timer Reduced Speed Extended running Holidays Holidays (MM:DD) 1: 01:01 - 01:03 2: 02:14 - 01:21 and so on - up to 24 holiday periods Holidays (MM:TT) 1: 01:01 - 01:03 2: 02:14 - 02:21 and so on - up to 24 holiday periods To return to the start menu at once – press and several times. Setting of extended running x1 The display is lit up 2. x4 Time settings 3. x1 4. x3 x1 9 Danvent DV TIME Date, time Syst: Running mode (Auto, Manual reduced, Man. norm., Off) 1. Select Extended running (Do not select Time/Date, because this is for setting the internal clock) 5. Extended running is activated for changes. Value to be changed flashes 6. To select the correct value 7. Confirm with OK. 8. Confirm with OK when all values are OK. The system will automatically return to the start menu after some minutes. 9. To return to the start menu at once – press and several times. Time/Date Timer Normal Speed Timer Reduced Speed Extended running Holidays Extended running xx min Time in ext. Running: yy (minutes already spent of the total extended running time) Setting of min/max supply air temperature Access to this menu requires log on at the high-authority level – ”Admin”. Follow the steps below The display shows x1 The display is lit up 2. x5 Access rights 3. x2 Select - Log on 4. Log on Enter password **** Actual level: Operator Digit to be changed flashes. Factory logged Actual level: password, exclusively for service partners. Admin 5. x2 Return to start menu 6. x6 Temperature 7. 1. Danvent DV TIME Date, time Syst: Running mode (Auto, Manual reduced, Man. norm., Off) x2 If the system is configured for cascaded room temperature control, this menu with max/min supply air temperature is displayed. Running mode Temperature Air control Time settings Manuel/Auto Settings Configuration Access Rights With Caskaded control max/min supply air setp Max: xx ˚C Min: yy ˚C 8. Value to be changed flashes. Confirm selected value with OK 9. Select and confirm new set point temperature. 10. 11. x2 x6 The system is now logged on at the Admin level and unskilled persons could change important parameters and settings to values that will cause malfunction of the system. Go to the start menu to return the system immediatlely to the lowest access level – Operator. Access rights Log on Log off Change password 12. Log off? Select - Log off and select the answer – Yes No Actual level: Admin 13. System returns to the start menu and is now logged on at the Operator-level. 10 Restore Systemair factory settings or latest user parameters and settings Access to this menu requires log on at the high-authority level – ”Admin”. Follow the steps below x1 The display is lit up 2. x5 Access rights 3. x2 Select Log on Danvent DV TIME Date, time Syst: Running mode (Auto, Manual reduced, Man. norm., Off) 1. Log on Enter password **** Actual level: Operator Digit to be changed flashes. Factory logged Actual level: password, exclusively for service partners. Admin 4. Running mode Temperature ... Access rights 5. x2 Return to start menu 6. x2 Settings 7. x1 Menus in settings Control temp Control flow Alarm settings 8. x3 Select: – Restore factory settings: Yes/No – Restore user settings: Yes/No Restore factory settings: No Restore user settings: No Confirm with OK for selected alternative. Values to be changed flashes. 9. 10. x1 To select menu: – Save user setings: Yes/No 11. Value to be changed flashes. Confirm selected value with OK. 12. Select and confirm new setpoint. Save user settings: No The system is now logged on at the Admin level and unskilled persons could change important parameters and settings to values that will cause malfunction of the system. Go to the start menu to return the system immediatlely to the lowest access level – Operator 13. x2 14. x2 Access rights 15. x1 Select - Log off and select the answer – Yes 16. 11 The display shows System returns to the start menu and is now logged on at the Operator-level. Log on Log off Change password Log off? No Actual level: Admin Systemair A/S – FebruarY 2014 Systemair A/S Ved Milepælen 7 DK-8361 Hasselager Tel. +45 87 38 75 00 Fax +45 87 38 75 01 [email protected] www.systemair.dk 12
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement