CB Report-990723

CB Report-990723
Page 3 of 73
Report No. 11021109 001
Summary of testing:
Tests performed (name of test and test clause):
All applicable tests as described in Test Case
and Measurement Sections were performed.
The maximum ambient temperature is specified
as 35 °C.
The CPU is used as follows during test.
- Intel® Core i7 Mobile Processor 620M, speed
2.66GHz.
- Intel® Core i5 Mobile Processor 540M, speed
2.53GHz.
- Intel® Core i3 Mobile Processor 350M, speed
2.27GHz.
- Intel® Celeron P4500 Processor, speed
1.86GHz.
Highest load according to 1.2.2.1 for this
equipment which its contains max. rating of the
optional optical drives and the HDD, brightness
and contrast for LCD panel and charged with
empty battery packs. Dummy load of 2.5W in
connection to represent each USB load.
Testing location:
All tests as described in Test Case and
Measurement Sections were performed at the
laboratory described on page 2.
Summary of compliance with National Differences:
EU Group Differences, EU Special National Conditions, EU A-Deviations, AT, CA, CH, DE, FR, GB, IT,
KR, NL, PL, SI, US.
Explanation of used codes: AT=Austria, AU=Australia, CA=Canada, CH=Switzerland, DE=Germany,
DK=Denmark, FI=Finland, FR=France, GB=United Kingdom, IT=Italy, KR=Korea, NL=The Netherlands,
NO=Norway, PL=Poland, SE=Sweden, SI=Slovenia, US=United States of America.
For National Differences see corresponding Attachment.
Copy of marking plate(s):
This label drawing is a draft of an artwork for marking plates pending approval by National Certification
Bodies and it shall not be affixed to products prior to such an approval.
TRF No. IECEN60950_1C
Page 4 of 73
Report No. 11021109 001
Test item particulars .................................................. :
Equipment mobility .................................................... : [] movable [] hand-held
[x] transportable
[] stationary
[] for building-in [] direct plug-in
Connection to the mains............................................ : [] pluggable equipment [] permanent connection
[] detachable power supply cord
[] non-detachable power supply cord
[x] not directly connected to the mains
Operating condition ................................................... : [x] continuous
[] rated operating / resting time
Access location ........................................................ : [x] operator accessible
[] restricted access location
Over voltage category (OVC) ................................... : [] OVC I [] OVC II
[x] other: N/A
[] OVC III
[] OVC IV
Mains supply tolerance (%) or absolute mains supply Not directly connected to the mains
values ....................................................................... :
Tested for IT power systems .................................... : [] Yes
[x] No
IT testing, phase-phase voltage (V) ......................... : N/A
Class of equipment ................................................... : [] Class I [] Class II
[] Not classified
[x] Class III
Considered current rating (A) ................................... : N/A
Pollution degree (PD) ............................................... : [] PD 1
[x] PD 2
[] PD 3
IP protection class .................................................... : IPX0
Altitude during operation (m) .................................... : Up to 2000 m
Altitude of test laboratory (m) ................................... : Not over 2000 m
Mass of equipment (kg) ............................................ : 2.62 kg
Possible test case verdicts:
- test case does not apply to the test object.................: N/A
- test object does meet the requirement.......................: P (Pass)
- test object does not meet the requirement.................: F (Fail)
Testing ......................................................................... :
Date of receipt of test item ............................................: May, 2010
Date(s) of performance of tests ....................................: May - June, 2010
General remarks:
The test results presented in this report relate only to the object tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing testing
laboratory.
“(See Enclosure #)” refers to additional information appended to the report.
“(See appended table)” refers to a table appended to the report.
Note: This TRF includes EN Group Differences together with National Differences and Special
National Conditions, if any. All Differences are located in the Appendix to the main body of this TRF.
Throughout this report a point is used as the decimal separator.
The manufacturer's declaration, that the samples tested represent the products from each factory, is
available.
TRF No. IECEN60950_1C
Page 5 of 73
Report No. 11021109 001
General product information:
The equipment, models T510X, T511X (X can be 0-9 or blank) are NOTEBOOK COMPUTER for general
office use.
Both models are similar except for type designation.
There are some sources of CPU type provided as follows:
Intel® Core i7 Mobile Processor 620M, speed 2.66GHz.
Intel® Core i5 Mobile Processor 540M, speed 2.53GHz.
Intel® Core i5 Mobile Processor 520M, speed 2.40GHz.
Intel® Core i3 Mobile Processor 350M, speed 2.27GHz.
Intel® Core i3 Mobile Processor 330M, speed 2.13GHz.
Intel® Celeron P4500 Processor, speed 1.86GHz.
There are two types of backlight mode (LED or DC/AC inverter) provided, and therefore the DC/AC inverter
is optional used.
The external power adaptor and battery pack are approved products which were CB-scheme evaluated
according to IEC 60950-1, for detail information see appended table 1.5.1.
All Data ports of unit were complied with requirement of sub-clause 2.5.
Other comments:
This report contains all national deviation as the class III equipment itself is subject of this CB report, but
CB countries for external adapter should investigate this matter while the equipment under test is submitted
for national approval.
Factory(ies):
Kapok (Kunshan) Co.
No. 200, the 2nd Road, Export Processing Zone, Kunshan, Jiangsu Province 215300, P.R. China
Definition of variable(s):
Variable:
Range of variable:
Content:
X
0-9 or blank
For marketing purpose, no safety impact.
Attachments to this Test Report:
- Photo Documentation
- National Differences
- Measurement Section
TRF No. IECEN60950_1C
Page 6 of 73
Report No. 11021109 001
IEC/EN 60950-1
Clause
Requirement + Test
1
GENERAL
P
1.5
Components
P
1.5.1
General
See below.
P
Comply with IEC 60950 or relevant component
standard
(see appended table 1.5.1)
P
1.5.2
Evaluation and testing of components
Components certified to IEC
standards and/or their
harmonized standards, are
used within their ratings and
are checked for correct
application.
P
1.5.3
Thermal controls
No thermal controls provided.
N/A
1.5.4
Transformers
No transformers used except
for approved power adaptors.
N/A
1.5.5
Interconnecting cables
No interconnection cables
used.
N/A
1.5.6
Capacitors bridging insulation
No such components.
N/A
1.5.7
Resistors bridging insulation
No such components.
N/A
1.5.7.1
Resistors bridging functional, basic or
supplementary insulation
N/A
1.5.7.2
Resistors bridging double or reinforced insulation
between a.c. mains and other circuits
N/A
1.5.7.3
Resistors bridging double or reinforced insulation
between a.c. mains and antenna or coaxial cable
N/A
1.5.8
Components in equipment for IT power systems
Equipment is not directly
connected to the AC mains
supply.
N/A
1.5.9
Surge suppressors
Equipment is not directly
connected to the AC mains
supply.
N/A
1.5.9.1
General
N/A
1.5.9.2
Protection of VDRs
N/A
1.5.9.3
Bridging of functional insulation by a VDR
N/A
1.5.9.4
Bridging of basic insulation by a VDR
N/A
1.5.9.5
Bridging of supplementary, double or reinforced
insulation by a VDR
N/A
1.6
Power interface
TRF No. IECEN60950_1C
Result - Remark
Verdict
P
Page 7 of 73
Report No. 11021109 001
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
1.6.1
AC power distribution systems
Equipment is not directly
connected to the AC mains
supply.
1.6.2
Input current
See summary of testing in
page 3 for details. Results see
appended table 1.6.2.
1.6.3
Voltage limit of hand-held equipment
The equipment is not handheld equipment.
N/A
1.6.4
Neutral conductor
The equipment is not directly
connected to the mains supply.
N/A
1.7
Marking and instructions
1.7.1
Power rating
N/A
P
P
Marking label is located on
bottom side of enclosure.
P
Rated voltage(s) or voltage range(s) (V) .............. : See copy of marking plate (no
direct connection to the mains
supply).
N/A
Symbol for nature of supply, for d.c. only .............. : See copy of marking plate (no
direct connection to the mains
supply).
N/A
Rated frequency or rated frequency range (Hz).... : No direct connection to the AC
mains supply.
N/A
Rated current (mA or A) ....................................... : No direct connection to the AC
mains supply.
N/A
Manufacturer’s name or trade-mark or
See copy of marking plate.
identification mark ................................................. :
P
Model identification or type reference .................. : See copy of marking plate.
P
Symbol for Class II equipment only ...................... : The equipment is Class III
equipment.
N/A
Other markings and symbols ................................ : Other markings and symbols
do not give rise to
misunderstanding.
P
1.7.2
Safety instructions and marking
See below.
P
1.7.2.1
General
The user’s guide is provided to
the user containing safety
instructions.
P
1.7.2.2
Disconnect devices
No direct connection to the
mains supply.
N/A
1.7.2.3
Overcurrent protective device
The equipment is Class III
equipment.
N/A
TRF No. IECEN60950_1C
Page 8 of 73
Report No. 11021109 001
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
1.7.2.4
IT power distribution systems
The equipment is not directly
connected to the AC mains
supply.
1.7.2.5
Operator access with a tool
1.7.2.6
Ozone
The equipment does not
produce ozone.
N/A
1.7.3
Short duty cycles
The equipment is designed for
continuous operation.
N/A
1.7.4
Supply voltage adjustment ................................... : No voltage / frequency setting.
N/A
Methods and means of adjustment; reference to
See above.
installation instructions ......................................... :
N/A
1.7.5
Power outlets on the equipment ........................... : No standard power outlets
provided.
N/A
1.7.6
Fuse identification (marking, special fusing
characteristics, cross-reference) .......................... :
N/A
1.7.7
Wiring terminals
1.7.7.1
Protective earthing and bonding terminals ........... : No direct connection to the
mains supply.
N/A
1.7.7.2
Terminals for a.c. mains supply conductors
No direct connection to the
mains supply.
N/A
1.7.7.3
Terminals for d.c. mains supply conductors
No direct connection to the
mains supply.
N/A
1.7.8
Controls and indicators
See below.
1.7.8.1
Identification, location and marking ...................... : The marking of the stand-by
switch is located that indication
of function clearly.
1.7.8.2
Colours ................................................................ :
1.7.8.3
Symbols according to IEC 60417 .......................... : Marking for stand-by type
switch according 60417-1-IEC5009 (line half inside circle)
was marked on stand-by type
switch button.
1.7.8.4
Markings using figures ......................................... : No figures used.
N/A
1.7.9
Isolation of multiple power sources ...................... : Only one power source.
N/A
1.7.10
Thermostats and other regulating devices ........... : Neither thermostats nor other
regulating devices provided.
N/A
1.7.11
Durability
Compliance.
P
1.7.12
Removable parts
The required marking is not
placed on removable parts.
P
TRF No. IECEN60950_1C
Verdict
N/A
N/A
See below.
N/A
P
P
N/A
P
Page 9 of 73
Report No. 11021109 001
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
1.7.13
Replaceable batteries ........................................... : The battery pack is
exchangeable. Warning text
provided in user’s manual
accordingly.
P
Language(s) .......................................................... : English. Versions in other
languages will be provided
when national certificate
approval.

N/A
1.7.14
Equipment for restricted access locations ............. : The equipment is not intended
to be use in restricted access
locations.
2
PROTECTION FROM HAZARDS
P
2.1
Protection from electric shock and energy hazards
P
2.1.1
Protection in operator access areas
See below.
P
2.1.1.1
Access to energized parts
See below.
P
Test by inspection ..................................................: The NOTEBOOK COMPUTER
is supplied from an approved
power adaptor or battery pack
that provides only SELV.
P
Test with test finger (Figure 2A) ............................: No access with test finger to
any parts with only basic
insulation to TNV-3.
P
Test with test pin (Figure 2B) .................................:
N/A
Test with test probe (Figure 2C) ............................: The test probe cannot touch
pins of connector of TNV-3
circuit through any seams
within the appliance.
P
2.1.1.2
Battery compartments
TNV circuits are not accessible
when replace battery pack.
N/A
2.1.1.3
Access to ELV wiring
No ELV wiring.
N/A
Working voltage (Vpeak or Vrms); minimum
distance through insulation (mm)

2.1.1.4
Access to hazardous voltage circuit wiring
2.1.1.5
Energy hazards .....................................................: No energy hazards in operator
access area.
2.1.1.6
Manual controls
No conductive shafts of
operating knobs, handles,
levers and the like.
N/A
2.1.1.7
Discharge of capacitors in equipment
The equipment is Class III
equipment.
N/A
TRF No. IECEN60950_1C
N/A
P
Page 10 of 73
Report No. 11021109 001
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Measured voltage (V); time-constant (s) ................: See above.
2.1.1.8
Energy hazards – d.c. mains supply
No d.c. mains supply.
Verdict

N/A
a) Capacitor connected to the d.c. mains supply ..:
N/A
b) Internal battery connected to the d.c. mains
supply ....................................................................:
N/A
2.1.1.9
Audio amplifiers .....................................................: The voltage of speaker is
measured 2.11Vpeak.
2.1.2
Protection in service access areas
2.1.3
Protection in restricted access locations
2.2
SELV circuits
Supply from power adaptor or battery pack that is considered to carry SELV at
below 240VA only. No higher voltages generated.
P
2.2.1
General requirements
The circuits inside equipment
were SELV circuits.
P
2.2.2
Voltages under normal conditions (V) .................. : Between any conductor of the
SELV circuits, 42.4 V peak or
60 V d.c. is not exceeded.
P
2.2.3
Voltages under fault conditions (V) ...................... : Single fault did not cause
excessive voltage in SELV
circuits. The limits of 71 V peak
and 120 V d.c. were not
exceeded within 200 ms.
Furthermore, the SELV limits
(see subclause 2.2.2) were not
exceeded for longer than 200
ms.
P
2.2.4
Connection of SELV circuits to other circuits ......:
P
2.3
TNV circuits
2.3.1
Limits
2.3.2
P
N/A
The equipment is not limited to
be used in restricted access
locations.
Complied with subclauses
2.2.2 and 2.2.3.
N/A
P
See below.
P
Type of TNV circuits .............................................. : The modem module is an
approved component that
generates only signals within
the limits of SELV circuits. The
telecommunication network is
considered to be TNV-3 circuit.

Separation from other circuits and from accessible
parts
P
TRF No. IECEN60950_1C
See below.
Page 11 of 73
Report No. 11021109 001
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
2.3.2.1
General requirements
See below.
P
2.3.2.2
Protection by basic insulation
Basic insulation between TNV
and SELV provided.
Requirements of 6.2.2 are
applicable.
P
2.3.2.3
Protection by earthing
N/A
2.3.2.4
Protection by other constructions ......................... :
N/A
2.3.3
Separation from hazardous voltages
2.3.4
See below.
Verdict
P
Insulation employed............................................... : Both TNV separated to
primary by reinforced or
double insulation by the
certified power adaptor.

Connection of TNV circuits to other circuits
P
See below.
Insulation employed............................................... : TNV circuits separated to
primary by reinforced or
double insulation by the
certified power adaptor. TNV
circuits only connected to
SELV circuits by basic
insulation.

2.3.5
Test for operating voltages generated externally
2.4
Limited current circuits
2.4.1
General requirements
See below.
P
2.4.2
Limit values
See below.
P
Basic insulation provided. No
test for this clause.
N/A
P
Frequency (Hz) .......................................................: See appended table 2.4.2

Measured current (mA)...........................................: See appended table 2.4.2

Measured voltage (V) .............................................: 1) 1.12kV for Mitac /
M660JEINT-D
2) 1.39kV for Taiwan Sumida /
M660SRUINT-E

Measured circuit capacitance (nF or µF)................: 1) 100pF for Mitac /
M660JEINT-D
2) 100pF for Taiwan Sumida /
M660SRUINT-E

2.4.3
Connection of limited current circuits to other
circuits
P
2.5
Limited power sources
TRF No. IECEN60950_1C
Complied.
P
Page 12 of 73
Report No. 11021109 001
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
a) Inherently limited output
N/A
b) Impedance limited output
N/A
c) Regulating network limited output under normal
operating and single fault condition
See attachment measurement
section table 2.5.
d) Overcurrent protective device limited output
P
N/A
Max. output voltage (V), max. output current (A),
See attachment measurement
max. apparent power (VA)......................................: section table 2.5.

Current rating of overcurrent protective device (A)

2.6
Provisions for earthing and bonding
N/A
2.6.1
Protective earthing
N/A
2.6.2
Functional earthing
N/A
2.6.3
Protective earthing and protective bonding
conductors
N/A
2.6.3.1
General
N/A
2.6.3.2
Size of protective earthing conductors
N/A
2
Rated current (A), cross-sectional area (mm ),
AWG .......................................................................:
2.6.3.3
Size of protective bonding conductors

N/A
2
Rated current (A), cross-sectional area (mm ),
AWG .......................................................................:

Protective current rating (A), cross-sectional area
2
(mm ), AWG .......................................................... :

2.6.3.4
Resistance of earthing conductors and their
terminations; resistance (Ω), voltage drop (V), test
current (A), duration (min) ......................................:
N/A
2.6.3.5
Colour of insulation .................................................:
N/A
2.6.4
Terminals
N/A
2.6.4.1
General
N/A
2.6.4.2
Protective earthing and bonding terminals
N/A
Rated current (A), type, nominal thread diameter
(mm) ...................................................................... :

2.6.4.3
Separation of the protective earthing conductor
from protective bonding conductors
N/A
2.6.5
Integrity of protective earthing
N/A
2.6.5.1
Interconnection of equipment
N/A
2.6.5.2
Components in protective earthing conductors and
protective bonding conductors
N/A
TRF No. IECEN60950_1C
Page 13 of 73
Report No. 11021109 001
IEC/EN 60950-1
Clause
Requirement + Test
2.6.5.3
Disconnection of protective earth
N/A
2.6.5.4
Parts that can be removed by an operator
N/A
2.6.5.5
Parts removed during servicing
N/A
2.6.5.6
Corrosion resistance
N/A
2.6.5.7
Screws for protective bonding
N/A
2.6.5.8
Reliance on telecommunication network or cable
distribution system
N/A
2.7
Overcurrent and earth fault protection in primary circuits
With SELV supply from power adaptor or battery pack, no primary circuits inside.
N/A
2.7.1
Basic requirements
N/A
Instructions when protection relies on building
installation
N/A
2.7.2
Faults not simulated in 5.3.7
N/A
2.7.3
Short-circuit backup protection
N/A
2.7.4
Number and location of protective devices ...........:
N/A
2.7.5
Protection by several devices
N/A
2.7.6
Warning to service personnel ................................:
N/A
2.8
Safety interlocks
N/A
2.8.1
General principles
N/A
2.8.2
Protection requirements
N/A
2.8.3
Inadvertent reactivation
N/A
2.8.4
Fail-safe operation
N/A
2.8.5
Moving parts
N/A
2.8.6
Overriding
N/A
2.8.7
Switches and relays
N/A
2.8.7.1
Contact gaps (mm) ................................................:
N/A
2.8.7.2
Overload test
N/A
2.8.7.3
Endurance test
N/A
2.8.7.4
Electric strength test
N/A
2.8.8
Mechanical actuators
N/A
2.9
Electrical insulation
The unit is supplied from approved adaptor or battery pack that provides SELV.
Only SELV and approved modem module with TNV inside the unit.
TRF No. IECEN60950_1C
Result - Remark
Verdict
P
Page 14 of 73
Report No. 11021109 001
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
2.9.1
Properties of insulating materials
Natural rubber, asbestos or
hygroscopic materials are not
used.
P
2.9.2
Humidity conditioning
See below.
P
Relative humidity (%), temperature (°C) ................: 48 h, 95%, 25°C

2.9.3
Grade of insulation
P
2.9.4
Separation from hazardous voltages
The adequate levels of safety
insulation is provided and
maintained to comply with the
requirements of this standard.
N/A
Method(s) used ......................................................:

2.10
Clearances, creepage distances and distances through insulation
The unit is supplied from approved adaptor or battery pack that provides SELV.
Only SELV and approved modem module with TNV inside the unit.
P
2.10.1
General
P
2.10.1.1
Frequency ..............................................................: The frequency does not
exceeding 30kHz.
P
2.10.1.2
Pollution degrees ...................................................: 2
P
2.10.1.3
Reduced values for functional insulation
P
2.10.1.4
Intervening unconnected conductive parts
N/A
2.10.1.5
Insulation with varying dimensions
N/A
2.10.1.6
Special separation requirements
N/A
2.10.1.7
Insulation in circuits generating starting pulses
N/A
2.10.2
Determination of working voltage
See below.
P
2.10.2.1
General
Considered.
P
2.10.2.2
RMS working voltage
P
2.10.2.3
Peak working voltage
P
2.10.3
Clearances
See below.
P
2.10.3.1
General
Annex F is considered.
P
2.10.3.2
Mains transient voltages
N/A
a) AC mains supply ...............................................:
N/A
b) Earthed d.c. mains supplies ..............................:
N/A
c) Unearthed d.c. mains supplies ..........................:
N/A
d) Battery operation ...............................................:
N/A
2.10.3.3
Clearances in primary circuits
N/A
2.10.3.4
Clearances in secondary circuits
TRF No. IECEN60950_1C
See below.
See 5.3.4.
See clauses 2.10.3 and 5.3.4.
P
Page 15 of 73
Report No. 11021109 001
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
2.10.3.5
Clearances in circuits having starting pulses
N/A
2.10.3.6
Transients from a.c. mains supply .........................:
N/A
2.10.3.7
Transients from d.c. mains supply .........................:
N/A
2.10.3.8
Transients from telecommunication networks and
1500Vpk
cable distribution systems .....................................:
2.10.3.9
Measurement of transient voltage levels
N/A
a) Transients from a mains supply
N/A
For an a.c. mains supply .......................................:
N/A
For a d.c. mains supply .........................................:
N/A
b) Transients from a telecommunication network ..:
N/A
P
2.10.4
Creepage distances
See below.
P
2.10.4.1
General
Considered.
P
2.10.4.2
Material group and comparative tracking index
Material group IIIb assumed.
P
CTI tests .................................................................: Min. 100

2.10.4.3
Minimum creepage distances
P
2.10.5
Solid insulation
N/A
2.10.5.1
General
N/A
2.10.5.2
Distances through insulation
N/A
2.10.5.3
Insulating compound as solid insulation
N/A
2.10.5.4
Semiconductor devices
N/A
2.10.5.5
Cemented joints
N/A
2.10.5.6
Thin sheet material – General
N/A
2.10.5.7
Separable thin sheet material
N/A
Number of layers (pcs) ..........................................:
See attachment measurement
section table 2.10.3 and
2.10.4.

2.10.5.8
Non-separable thin sheet material
N/A
2.10.5.9
Thin sheet material – standard test procedure
N/A
Electric strength test
2.10.5.10
Thin sheet material – alternative test procedure
Electric strength test

N/A

2.10.5.11
Insulation in wound components
N/A
2.10.5.12
Wire in wound components
N/A
Working voltage .....................................................:
N/A
a) Basic insulation not under stress ......................:
N/A
b) Basic, supplementary, reinforced insulation ......:
N/A
TRF No. IECEN60950_1C
Page 16 of 73
Report No. 11021109 001
IEC/EN 60950-1
Clause
2.10.5.13
Requirement + Test
Result - Remark
Verdict
c) Compliance with Annex U .................................:
N/A
Two wires in contact inside wound component;
angle between 45° and 90° ...................................:
N/A
Wire with solvent-based enamel in wound
components
N/A
Electric strength test

Routine test
N/A
Additional insulation in wound components
N/A
Working voltage .....................................................:
N/A
- Basic insulation not under stress ........................:
N/A
- Supplementary, reinforced insulation ..................:
N/A
2.10.6
Construction of printed boards
N/A
2.10.6.1
Uncoated printed boards
N/A
2.10.6.2
Coated printed boards
N/A
2.10.6.3
Insulation between conductors on the same inner
surface of a printed board
N/A
2.10.6.4
Insulation between conductors on different layers
of a printed board
N/A
Distance through insulation
N/A
Number of insulation layers (pcs) ..........................:
N/A
2.10.7
Component external terminations
N/A
2.10.8
Tests on coated printed boards and coated
components
N/A
2.10.8.1
Sample preparation and preliminary inspection
N/A
2.10.8.2
Thermal conditioning
N/A
2.10.8.3
Electric strength test
N/A
2.10.8.4
Abrasion resistance test
N/A
2.10.9
Thermal cycling
N/A
2.10.10
Test for Pollution Degree 1 environment and
insulating compound
N/A
2.10.11
Tests for semiconductor devices and cemented
joints
N/A
2.10.12
Enclosed and sealed parts
N/A
3
WIRING, CONNECTIONS AND SUPPLY
P
3.1
General
P
2.10.5.14
TRF No. IECEN60950_1C
Page 17 of 73
Report No. 11021109 001
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
3.1.1
Current rating and overcurrent protection
All internal wires are UL
recognized wiring which is PVC
insulated, rated VW-1, min.
80°C. Internal wiring gauge is
suitable for current intended to
be carried.
P
3.1.2
Protection against mechanical damage
Wires do not touch sharp
edges and heatsinks, which
could damage the insulation
and cause hazards.
P
3.1.3
Securing of internal wiring
Internal wires are secured by
soldering and quick connector
so that a loosening of the
terminal connection is unlikely.
P
3.1.4
Insulation of conductors
The insulation of the individual
conductors is suitable for the
application and the working
voltage. For the insulation
material see 3.1.1.
P
3.1.5
Beads and ceramic insulators
Not used.
N/A
3.1.6
Screws for electrical contact pressure
No such screws.
N/A
3.1.7
Insulating materials in electrical connections
All current carrying
connections are metal to
metal.
N/A
3.1.8
Self-tapping and spaced thread screws
No self-tapping or spaced
thread screws used.
N/A
3.1.9
Termination of conductors
All conductors are reliably
secured.
P
10 N pull test
Applied and passed.
P
3.1.10
Sleeving on wiring
No sleeving used as
supplementary insulation.
3.2
Connection to a mains supply
N/A
3.2.1
Means of connection
N/A
3.2.1.1
Connection to an a.c. mains supply
N/A
3.2.1.2
Connection to a d.c. mains supply
N/A
3.2.2
Multiple supply connections
N/A
3.2.3
Permanently connected equipment
N/A
Number of conductors, diameter of cable and
conduits (mm) ....................................................... :
3.2.4
Appliance inlets
TRF No. IECEN60950_1C
Verdict
N/A

N/A
Page 18 of 73
Report No. 11021109 001
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
3.2.5
Power supply cords
N/A
3.2.5.1
AC power supply cords
N/A
Type ...................................................................... :

Rated current (A), cross-sectional area (mm²),
AWG ..................................................................... :

3.2.5.2
DC power supply cords
N/A
3.2.6
Cord anchorages and strain relief
N/A
Mass of equipment (kg), pull (N) ......................... :

Longitudinal displacement (mm) ........................... :

3.2.7
Protection against mechanical damage
N/A
3.2.8
Cord guards
N/A
Diameter or minor dimension D (mm); test mass
(g) ......................................................................... :

Radius of curvature of cord (mm) .......................... :

3.2.9
Supply wiring space
N/A
3.3
Wiring terminals for connection of external conductors
N/A
3.3.1
Wiring terminals
N/A
3.3.2
Connection of non-detachable power supply cords
N/A
3.3.3
Screw terminals
N/A
3.3.4
Conductor sizes to be connected
N/A
Class III equipment.
Rated current (A), cord/cable type, cross-sectional
2
area (mm ) ............................................................. :
3.3.5

Wiring terminal sizes
N/A
Rated current (A), type, nominal thread diameter
(mm) ..................................................................... :

3.3.6
Wiring terminal design
N/A
3.3.7
Grouping of wiring terminals
N/A
3.3.8
Stranded wire
N/A
3.4
Disconnection from the mains supply
N/A
3.4.1
General requirement
3.4.2
Disconnect devices
N/A
3.4.3
Permanently connected equipment
N/A
3.4.4
Parts which remain energized
N/A
TRF No. IECEN60950_1C
No direct connection to the
mains supply.
N/A
Page 19 of 73
Report No. 11021109 001
IEC/EN 60950-1
Clause
Requirement + Test
3.4.5
Switches in flexible cords
N/A
3.4.6
Number of poles - single-phase and d.c.
equipment
N/A
3.4.7
Number of poles - three-phase equipment
N/A
3.4.8
Switches as disconnect devices
N/A
3.4.9
Plugs as disconnect devices
N/A
3.4.10
Interconnected equipment
N/A
3.4.11
Multiple power sources
N/A
3.5
Interconnection of equipment
3.5.1
General requirements
3.5.2
Types of interconnection circuits .......................... : Interconnection circuits of
SELV through the connectors.
3.5.3
ELV circuits as interconnection circuits
3.5.4
Data ports for additional equipment
4
PHYSICAL REQUIREMENTS
4.1
Stability
Angle of 10°
Result - Remark
Verdict
P
See below.
P
P
N/A
The data ports are comply with
sub-clause 2.5.
P
P
N/A
Less than 7kg.
Test force (N) ........................................................ :
N/A
N/A
4.2
Mechanical strength
4.2.1
General
See below. After tests, unit
comply with 2.1.1, 2.10 and
4.4.1.
P
4.2.2
Steady force test, 10 N
10 N applied to components
other than parts serving as an
enclosure.
P
4.2.3
Steady force test, 30 N
No inner enclosure.
4.2.4
Steady force test, 250 N
250 N applied to outer
enclosure of Notebook
Computer. No energy or other
hazards.
4.2.5
Impact test
Not applied for transportable
equipment.
4.2.6
P
N/A
P
N/A
Fall test
N/A
Swing test
N/A
Drop test; height (mm) .......................................... : No hazards.
TRF No. IECEN60950_1C
P
Page 20 of 73
Report No. 11021109 001
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
4.2.7
Stress relief test
After 7 h for Notebook
Computer (for all sources) and
battery pack enclosure at 73°C
cooling down to room
temperature, no shrinkage,
distortion or loosing of
enclosure of battery pack and
Notebook Computer was
noticeable on this equipment.
4.2.8
Cathode ray tubes
No CRT.
Picture tube separately certified ........................... :
Verdict
P
N/A
N/A
4.2.9
High pressure lamps
4.2.10
Wall or ceiling mounted equipment; force (N) ...... : Not such equipment.
4.3
Design and construction
4.3.1
Edges and corners
4.3.2
Handles and manual controls; force (N) ................ : None, which could cause
hazards.
N/A
4.3.3
Adjustable controls
No safety relevant adjustable
controls provided.
N/A
4.3.4
Securing of parts
Electrical and mechanical
connections can be expected
to withstand usual mechanical
stress. For the protection
solder pins are used.
P
4.3.5
Connection by plugs and sockets
Mismatch of connectors were
prevented by incompatible
form or location.
P
4.3.6
Direct plug-in equipment
4.3.7
No high pressure lamp.
N/A
N/A
P
All edges or corners
accessible to operator are
rounded and smoothed.
P
N/A
Torque .................................................................. :

Compliance with the relevant mains plug standard
............................................................................... :
N/A
Heating elements in earthed equipment
N/A
TRF No. IECEN60950_1C
Page 21 of 73
Report No. 11021109 001
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
4.3.8
Batteries
1. The RTC battery is
protected from reverse
charging by D28.
2. All battery packs are
approved components and
no reverse polarity
installation is possible due
to design of pack.
3. The normal charging
voltage and current for
main battery pack are
compatible with output
characteristics respectively.
4. The discharge current for
battery pack is compatible
with output characteristics
of all sources of battery
pack.
Results see appended table
4.3.8 and 5.3.
P
- Overcharging of a rechargeable battery
Same as above.
P
- Unintentional charging of a non-rechargeable
battery
Same as above.
P
- Reverse charging of a rechargeable battery
Same as above.
P
- Excessive discharging rate for any battery
Same as above.
P
4.3.9
Oil and grease
N/A
4.3.10
Dust, powders, liquids and gases
N/A
4.3.11
Containers for liquids or gases
N/A
4.3.12
Flammable liquids ................................................. :
N/A
Quantity of liquid (l) ............................................... :
N/A
Flash point (°C) ..................................................... :
N/A
4.3.13
Radiation
See below.
P
4.3.13.1
General
See below.
P
4.3.13.2
Ionizing radiation
4.3.13.3
N/A
Measured radiation (pA/kg) .................................. :

Measured high-voltage (kV) ................................. :

Measured focus voltage (kV) ................................ :

CRT markings ....................................................... :

Effect of ultraviolet (UV) radiation on materials
N/A
Part, property, retention after test, flammability
classification ......................................................... :
N/A
TRF No. IECEN60950_1C
Page 22 of 73
Report No. 11021109 001
IEC/EN 60950-1
Clause
Requirement + Test
4.3.13.4
Human exposure to ultraviolet (UV) radiation ...... :
4.3.13.5
Laser (including LEDs)
Result - Remark
Verdict
N/A
LED used as indicating lights.
All optional optical drives were
evaluated according to
relevant standard for laser
product. Therefore, complied
with this clause without further
test.
Laser class ............................................................ : Laser Class 1 for all optional
optical drives.
P

4.3.13.6
Other types ........................................................... :
N/A
4.4
Protection against hazardous moving parts
4.4.1
General
4.4.2
Protection in operator access areas ..................... : Moving parts are not
accessible by test finger.
P
4.4.3
Protection in restricted access locations .............. : Not limited for restricted
access locations.
N/A
4.4.4
Protection in service access areas
N/A
4.5
Thermal requirements
4.5.1
General
No exceeding temperature.
P
4.5.2
Temperature tests
See appended table 4.5.
P
P
DC fan is protected by
enclosure. Other motors are
used in the certified HDD and
all optional optical drives.
P
P
Normal load condition per Annex L ...................... : See Annex L.

4.5.3
Temperature limits for materials
See appended table 4.5.
P
4.5.4
Touch temperature limits
See appended table 4.5.
P
4.5.5
Resistance to abnormal heat ................................ :
4.6
Openings in enclosures
4.6.1
Top and side openings
N/A
P
Transportable equipment
Dimensions (mm) .................................................. :
4.6.2
Bottoms of fire enclosures

Transportable equipment
Construction of the bottom, dimensions (mm) ...... :
4.6.3
Doors or covers in fire enclosures
4.6.4
Openings in transportable equipment
TRF No. IECEN60950_1C
N/A
N/A

N/A
See below.
P
Page 23 of 73
Report No. 11021109 001
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
4.6.4.1
Constructional design measures
See below.
Dimensions (mm) .................................................. : See attachment measurement
section table 4.6.1, 4.6.2.
Verdict
P

4.6.4.2
Evaluation measures for larger openings
N/A
4.6.4.3
Use of metallized parts
N/A
4.6.5
Adhesives for constructional purposes
N/A
Conditioning temperature (°C), time (weeks) ........ :

4.7
Resistance to fire
P
4.7.1
Reducing the risk of ignition and spread of flame
See below.
Method 1, selection and application of components Materials with suitable
wiring and materials
flammability classes are used
(see appended table 4.7).
Method 2, application of all of simulated fault
condition tests
P
P
N/A
4.7.2
Conditions for a fire enclosure
See below.
P
4.7.2.1
Parts requiring a fire enclosure
Having employed the following
parts:
components in secondary
circuits;
insulated wiring
The fire enclosure is required.
P
4.7.2.2
Parts not requiring a fire enclosure
4.7.3
Materials
4.7.3.1
General
See appended table 1.5.1 for
PCB material.
P
4.7.3.2
Materials for fire enclosures
See appended table 1.5.1 for
enclosure material.
P
4.7.3.3
Materials for components and other parts outside
fire enclosures
4.7.3.4
Materials for components and other parts inside
fire enclosures
4.7.3.5
Materials for air filter assemblies
N/A
4.7.3.6
Materials used in high-voltage components
N/A
5
ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS
P
5.1
Touch current and protective conductor current
P
5.1.1
General
TRF No. IECEN60950_1C
N/A
P
N/A
Internal components except
small parts are flammability
class V-2, HF-2 or better.
See below.
P
P
Page 24 of 73
Report No. 11021109 001
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
5.1.2
Configuration of equipment under test (EUT)
N/A
5.1.2.1
Single connection to an a.c. mains supply
N/A
5.1.2.2
Redundant multiple connections to an a.c. mains
supply
N/A
5.1.2.3
Simultaneous multiple connections to an a.c.
mains supply
N/A
5.1.3
Test circuit
5.1.4
Application of measuring instrument
N/A
5.1.5
Test procedure
N/A
5.1.6
Test measurements
Using figure 5A.
See below.
Verdict
P
P
Supply voltage (V) ................................................ : See clause 5.1.8.1.

Measured touch current (mA) ............................... : See clause 5.1.8.1.

Max. allowed touch current (mA) .......................... : See clause 5.1.8.1.

Measured protective conductor current (mA) ....... :

Max. allowed protective conductor current (mA) ... :

5.1.7
Equipment with touch current exceeding 3,5 mA
N/A
5.1.7.1
General ................................................................. :
N/A
5.1.7.2
Simultaneous multiple connections to the supply
N/A
5.1.8
Touch currents to telecommunication networks and See below.
cable distribution systems and from
telecommunication networks
P
5.1.8.1
Limitation of the touch current to a
telecommunication network or to a cable
distribution system
P
5.1.8.2
See below.
Supply voltage (V) ................................................ : 264Vac for power adaptor.

Measured touch current (mA) ............................... : See attachment measurement
section table 5.1.6.

Max. allowed touch current (mA) .......................... : 0.25

Summation of touch currents from
telecommunication networks
N/A
a) EUT with earthed telecommunication ports ..... :
N/A
b) EUT whose telecommunication ports have no
reference to protective earth
N/A
5.2
Electric strength
5.2.1
General
Refer to clause 6.2.2.2.
P
5.2.2
Test procedure
Refer to clause 6.2.2.2.
P
TRF No. IECEN60950_1C
P
Page 25 of 73
Report No. 11021109 001
IEC/EN 60950-1
Clause
Requirement + Test
5.3
Abnormal operating and fault conditions
5.3.1
Protection against overload and abnormal
operation
See below.
P
5.3.2
Motors
Certified DC fan used and
other motors are used in the
certified HDD and all optional
optical drives. See appended
table 1.5.1 for details.
P
5.3.3
Transformers
5.3.4
Functional insulation .............................................. : Method c). Results see
appended table 5.3.
5.3.5
Electromechanical components
5.3.6
Audio amplifiers in ITE .......................................... : See 2.1.1.9.
P
5.3.7
Simulation of faults
See appended table 5.3.
P
5.3.8
Unattended equipment
None of the listed components
was provided.
5.3.9
Compliance criteria for abnormal operating and
fault conditions
See below.
P
5.3.9.1
During the tests
No fire occurred, no molten
metal emitted and no
deformation of enclosure.
P
5.3.9.2
After the tests
P
6
CONNECTION TO TELECOMMUNICATION NETWORKS
P
6.1
Protection of telecommunication network service persons, and users of other
equipment connected to the network, from hazards in the equipment
P
6.1.1
Protection from hazardous voltages
P
6.1.2
Separation of the telecommunication network from earth
P
6.1.2.1
Requirements
There is a sufficient insulation
provided between TNV-3
circuit and earth.
P
Supply voltage (V) ....................................................: There is no breakdown
between TNV and earthing of
power adaptor after applied
1500Vac according to 5.2.2.

Current in the test circuit (mA) .............................. :

Exclusions ............................................................. :
N/A
6.1.2.2
TRF No. IECEN60950_1C
Result - Remark
Verdict
P
N/A
No electromechanical
component.
P
N/A
N/A
Page 26 of 73
Report No. 11021109 001
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
6.2
Protection of equipment users from overvoltages on telecommunication networks
P
6.2.1
Separation requirements
P
Adequate electrical separation
Verdict
between TNV-3 to:
• Keyboard and external
enclosure
• SELV output ports
6.2.2
Electric strength test procedure
6.2.2.1
Impulse test
6.2.2.2
Steady-state test
No isolation breakdown.
See appended table 5.2.
P
6.2.2.3
Compliance criteria
Complied.
P
6.3
Protection of the telecommunication wiring system from overheating
See below.
P
N/A
N/A
Max. output current (A) ......................................... :

Current limiting method ........................................ :

7
CONNECTION TO CABLE DISTRIBUTION SYSTEMS
N/A
7.1
General
N/A
7.2
Protection of cable distribution system service
persons, and users of other equipment connected
to the system, from hazardous voltages in the
equipment
N/A
7.3
Protection of equipment users from overvoltages
on the cable distribution system
N/A
7.4
Insulation between primary circuits and cable
distribution systems
N/A
7.4.1
General
N/A
7.4.2
Voltage surge test
N/A
7.4.3
Impulse test
N/A
A
ANNEX A, TESTS FOR RESISTANCE TO HEAT AND FIRE
A.1
Flammability test for fire enclosures of movable
equipment having a total mass exceeding 18 kg,
and of stationary equipment (see 4.7.3.2)
A.1.1
Samples................................................................. :

Wall thickness (mm) .............................................. :

A.1.2
Conditioning of samples; temperature (°C) .......... :
N/A
A.1.3
Mounting of samples ............................................ :
N/A
TRF No. IECEN60950_1C
P
N/A
Page 27 of 73
Report No. 11021109 001
IEC/EN 60950-1
Clause
Requirement + Test
A.1.4
Test flame (see IEC 60695-11-3)
Result - Remark
Verdict
N/A
Flame A, B, C or D ................................................ :

A.1.5
Test procedure
N/A
A.1.6
Compliance criteria
N/A
Sample 1 burning time (s) ..................................... :

Sample 2 burning time (s) ..................................... :

Sample 3 burning time (s) ..................................... :

A.2
Flammability test for fire enclosures of movable equipment having a total mass not
exceeding 18 kg, and for material and components located inside fire enclosures
(see 4.7.3.2 and 4.7.3.4)
P
A.2.1
Samples, material .................................................. :

Wall thickness (mm) .............................................. :

A.2.2
Conditioning of samples; temperature (°C) .......... :
N/A
A.2.3
Mounting of samples ............................................ :
N/A
A.2.4
Test flame (see IEC 60695-11-4)
N/A
Flame A, B or C .................................................... :

A.2.5
Test procedure
N/A
A.2.6
Compliance criteria
N/A
A.2.7
Sample 1 burning time (s) ..................................... :

Sample 2 burning time (s) ..................................... :

Sample 3 burning time (s) ..................................... :

Alternative test acc. to IEC 60695-11-5, cl. 5 and 9
N/A
Sample 1 burning time (s) ..................................... :

Sample 2 burning time (s) ..................................... :

Sample 3 burning time (s) ..................................... :

A.3
Hot flaming oil test (see 4.6.2)
N/A
A.3.1
Mounting of samples
N/A
A.3.2
Test procedure
N/A
A.3.3
Compliance criterion
N/A
B
ANNEX B, MOTOR TESTS UNDER ABNORMAL CONDITIONS (see 4.7.2.2 and
5.3.2)
N/A
B.1
General requirements
N/A
Approved DC fan used.
Position ................................................................. :

Manufacturer ......................................................... :

TRF No. IECEN60950_1C
Page 28 of 73
Report No. 11021109 001
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
Type ...................................................................... :

Rated values ........................................................ :

B.2
Test conditions
N/A
B.3
Maximum temperatures
N/A
B.4
Running overload test
N/A
B.5
Locked-rotor overload test
N/A
Test duration (days) .............................................. :

Electric strength test: test voltage (V) ................... :

B.6
Running overload test for d.c. motors in secondary
circuits
N/A
B.6.1
General
N/A
B.6.2
Test procedure
N/A
B.6.3
Alternative test procedure
N/A
B.6.4
Electric strength test; test voltage (V) ................... :
N/A
B.7
Locked-rotor overload test for d.c. motors in
secondary circuits
N/A
B.7.1
General
N/A
B.7.2
Test procedure
N/A
B.7.3
Alternative test procedure
N/A
B.7.4
Electric strength test; test voltage (V) ................... :
N/A
B.8
Test for motors with capacitors
N/A
B.9
Test for three-phase motors
N/A
B.10
Test for series motors
N/A
C
Operating voltage (V) ........................................... :

ANNEX C, TRANSFORMERS (see 1.5.4 and 5.3.3)
N/A
Position ................................................................. :

Manufacturer ......................................................... :

Type ...................................................................... :

Rated values ........................................................ :

Method of protection .............................................. :

C.1
Overload test
N/A
C.2
Insulation
N/A
Protection from displacement of windings ............. :
N/A
TRF No. IECEN60950_1C
Page 29 of 73
Report No. 11021109 001
IEC/EN 60950-1
Clause
Requirement + Test
D
ANNEX D, MEASURING INSTRUMENTS FOR TOUCH-CURRENT TESTS
(see 5.1.4)
P
D.1
Measuring instrument
P
D.2
Alternative measuring instrument
N/A
E
ANNEX E, TEMPERATURE RISE OF A WINDING (see 1.4.13)
N/A
F
ANNEX F, MEASUREMENT OF CLEARANCES AND CREEPAGE DISTANCES
(see 2.10 and Annex G)
G
ANNEX G, ALTERNATIVE METHOD FOR DETERMINING MINIMUM
CLEARANCES
N/A
G.1
Clearances
N/A
G.1.1
General
N/A
G.1.2
Summary of the procedure for determining
minimum clearances
N/A
G.2
Determination of mains transient voltage (V)
N/A
G.2.1
AC mains supply ................................................... :
N/A
G.2.2
Earthed d.c. mains supplies ................................. :
N/A
G.2.3
Unearthed d.c. mains supplies ............................. :
N/A
G.2.4
Battery operation .................................................. :
N/A
G.3
Determination of telecommunication network
transient voltage (V) ............................................. :
N/A
G.4
Determination of required withstand voltage (V)
N/A
G.4.1
Mains transients and internal repetitive peaks ..... :
N/A
G.4.2
Transients from telecommunication networks ...... :
N/A
G.4.3
Combination of transients
N/A
G.4.4
Transients from cable distribution systems
N/A
G.5
Measurement of transient voltages (V)
N/A
a) Transients from a mains supply
N/A
For an a.c. mains supply
N/A
For a d.c. mains supply
N/A
b) Transients from a telecommunication network
N/A
G.6
Determination of minimum clearances ................. :
N/A
H
ANNEX H, IONIZING RADIATION (see 4.3.13)
N/A
TRF No. IECEN60950_1C
Result - Remark
Complied.
Verdict
P
Page 30 of 73
Report No. 11021109 001
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
J
ANNEX J, TABLE OF ELECTROCHEMICAL POTENTIALS (see 2.6.5.6)
Metal(s) used ........................................................ :
Verdict
N/A

K
ANNEX K, THERMAL CONTROLS (see 1.5.3 and 5.3.8)
N/A
K.1
Making and breaking capacity
N/A
K.2
Thermostat reliability; operating voltage (V) ......... :
N/A
K.3
Thermostat endurance test; operating voltage (V) :
N/A
K.4
Temperature limiter endurance; operating voltage
(V) ......................................................................... :
N/A
K.5
Thermal cut-out reliability
N/A
K.6
Stability of operation
N/A
L
ANNEX L, NORMAL LOAD CONDITIONS FOR SOME TYPES OF ELECTRICAL
BUSINESS EQUIPMENT (see 1.2.2.1 and 4.5.2)
L.1
Typewriters
N/A
L.2
Adding machines and cash registers
N/A
L.3
Erasers
N/A
L.4
Pencil sharpeners
N/A
L.5
Duplicators and copy machines
N/A
L.6
Motor-operated files
N/A
L.7
Other business equipment
M
ANNEX M, CRITERIA FOR TELEPHONE RINGING SIGNALS (see 2.3.1)
N/A
M.1
Introduction
N/A
M.2
Method A
N/A
M.3
Method B
N/A
M.3.1
Ringing signal
N/A
M.3.1.1
Frequency (Hz) ..................................................... :

M.3.1.2
Voltage (V) ............................................................ :

M.3.1.3
Cadence; time (s), voltage (V) .............................. :

M.3.1.4
Single fault current (mA) ....................................... :

M.3.2
Tripping device and monitoring voltage ................ :
N/A
M.3.2.1
Conditions for use of a tripping device or a
monitoring voltage
N/A
M.3.2.2
Tripping device
N/A
TRF No. IECEN60950_1C
See summary of testing.
P
P
Page 31 of 73
Report No. 11021109 001
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
M.3.2.3
Monitoring voltage (V) .......................................... :
N/A
N
ANNEX N, IMPULSE TEST GENERATORS (see 1.5.7.2, 1.5.7.3, 2.10.3.9, 6.2.2.1,
7.3.2, 7.4.3 and Clause G.5)
N/A
N.1
ITU-T impulse test generators
N/A
N.2
IEC 60065 impulse test generator
N/A
P
ANNEX P, NORMATIVE REFERENCES
Q
ANNEX Q, Voltage dependent resistors (VDRs) (see 1.5.9.1)
N/A
a) Preferred climatic categories ............................ :
N/A
b) Maximum continuous voltage ........................... :
N/A
c) Pulse current ..................................................... :
N/A
R
Annex R, EXAMPLES OF REQUIREMENTS FOR QUALITY CONTROL
PROGRAMMES
N/A
R.1
Minimum separation distances for unpopulated
coated printed boards (see 2.10.6.2)
N/A
R.2
Reduced clearances (see 2.10.3)
N/A
S
ANNEX S, PROCEDURE FOR IMPULSE TESTING (see 6.2.2.3)
N/A
S.1
Test equipment
N/A
S.2
Test procedure
N/A
S.3
Examples of waveforms during impulse testing
N/A
T
ANNEX T, GUIDANCE ON PROTECTION AGAINST INGRESS OF WATER
(see 1.1.2)
N/A


U
ANNEX U, INSULATED WINDING WIRES FOR USE WITHOUT INTERLEAVED
INSULATION (see 2.10.5.4)
N/A

V
ANNEX V, AC POWER DISTRIBUTION SYSTEMS (see 1.6.1)
N/A
V.1
Introduction
N/A
V.2
TN power distribution systems
N/A
TRF No. IECEN60950_1C
Page 32 of 73
Report No. 11021109 001
IEC/EN 60950-1
Clause
Requirement + Test
V.3
TT power distribution systems
N/A
V.4
IT power distribution systems
N/A
W
ANNEX W, SUMMATION OF TOUCH CURRENTS
N/A
W.1
Touch current from electronic circuits
N/A
W.1.1
Floating circuits
N/A
W.1.2
Earthed circuits
N/A
W.2
Interconnection of several equipments
N/A
W.2.1
Isolation
N/A
W.2.2
Common return, isolated from earth
N/A
W.2.3
Common return, connected to protective earth
N/A
X
ANNEX X, MAXIMUM HEATING EFFECT IN TRANSFORMER TESTS (see clause
C.1)
N/A
X.1
Determination of maximum input current
N/A
X.2
Overload test procedure
N/A
Y
ANNEX Y, ULTRAVIOLET LIGHT CONDITIONING TEST (see 4.3.13.3)
N/A
Y.1
Test apparatus ...................................................... :
N/A
Y.2
Mounting of test samples ...................................... :
N/A
Y.3
Carbon-arc light-exposure apparatus ................... :
N/A
Y.4
Xenon-arc light exposure apparatus ..................... :
N/A
Z
ANNEX Z, OVERVOLTAGE CATEGORIES (see 2.10.3.2 and Clause G.2)
AA
ANNEX AA, MANDREL TEST (see 2.10.5.8)
BB
ANNEX BB, CHANGES IN THE SECOND EDITION
TRF No. IECEN60950_1C
Result - Remark
Verdict
P
N/A

Page 33 of 73
Report No. 11021109 001
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
EN 60950-1:2006 – CENELEC COMMON MODIFICATIONS
Contents
Add the following annexes:
Annex ZA (normative)
Normative references to international publications with
their corresponding European publications
Annex ZB (normative)
Special national conditions
Annex ZC (informative) A-deviations
P
General
Delete all the “country” notes in the reference document according to the following
list:
1.4.8
Note 2
1.5.1
Note 2 & 3
1.5.7.1
Note
1.5.8
Note 2
1.5.9.4
Note
1.7.2.1
Note 4, 5 & 6
2.2.3
Note
2.2.4
Note
2.3.2
Note
2.3.2.1 Note 2
2.3.4
Note 2
2.6.3.3
Note 2 & 3
2.7.1
Note
2.10.3.2 Note 2
2.10.5.13 Note 3
3.2.1.1 Note
3.2.4
Note 3.
2.5.1
Note 2
4.3.6
Note 1 & 2
4.7
Note 4
4.7.2.2
Note
4.7.3.1 Note 2
5.1.7.1
Note 3 & 4
5.3.7
Note 1
6
Note 2 & 5
6.1.2.1
Note 2
6.1.2.2
Note
6.2.2
Note 6.
2.2.1
Note 2
6.2.2.2
Note
7.1
Note 3
7.2
Note
7.3
Note 1 & 2
G.2.1
Note 2
Annex H Note 2
P
1.3.Z1
Add the following subclause:
1.3.Z1 Exposure to excessive sound pressure
The apparatus shall be so designed and constructed as to present no danger when
used for its intended purpose, either in normal operating conditions or under fault
conditions, particularly providing protection against exposure to excessive sound
pressures from headphones or earphones.
N/A
NOTE Z1 A new method of measurement is described in EN 50332-1, Sound system
equipment:
Headphones and earphones associated with portable audio equipment - Maximum sound
pressure level measurement methodology and limit considerations - Part 1: General method
for “one package equipment”, and in EN 50332-2, Sound system equipment: Headphones
and earphones associated with portable audio equipment - Maximum sound pressure level
measurement methodology and limit considerations - Part 2: Guidelines to associate sets
with headphones coming from different manufacturers.
1.5.1
Add the following NOTE:
N/A
NOTE Z1 The use of certain substances in electrical and electronic equipment is restricted
within the EU: see Directive 2002/95/EC
1.7.2.1
Add the following NOTE:
NOTE Z1 In addition, the instructions shall include, as far as applicable, a warning that
excessive sound pressure from earphones and headphones can cause hearing loss
TRF No. IECEN60950_1C
N/A
Page 34 of 73
Report No. 11021109 001
IEC/EN 60950-1
Clause
Requirement + Test
2.7.1
Replace the subclause as follows:
Basic requirements
To protect against excessive current, short-circuits and earth faults in PRIMARY
CIRCUITS, protective devices shall be included either as integral parts of the
equipment or as parts of the building installation, subject to the following, a), b) and
c):
a) except as detailed in b) and c), protective devices necessary to comply with the
requirements of 5.3 shall be included as parts of the equipment;
b) for components in series with the mains input to the equipment such as the
supply cord, appliance coupler, r.f.i. filter and switch, short-circuit and earth fault
protection may be provided by protective devices in the building installation;
c) it is permitted for PLUGGABLE EQUIPMENT TYPE B or PERMANENTLY
CONNECTED EQUIPMENT, to rely on dedicated overcurrent and short-circuit
protection in the building installation, provided that the means of protection, e.g.
fuses or circuit breakers, is fully specified in the installation instructions.
If reliance is placed on protection in the building installation, the installation
instructions shall so state, except that for PLUGGABLE EQUIPMENT TYPE A the
building installation shall be regarded as providing protection in accordance with the
rating of the wall socket outlet.
N/A
2.7.2
This subclause has been declared ‘void’.
N/A
3.2.3
Delete the NOTE in Table 3A, and delete also in this table the conduit sizes in
parentheses.
N/A
3.2.5.1
Replace
“60245 IEC 53” by “H05 RR-F”;
“60227 IEC 52” by “H03 VV-F or H03 VVH2-F”;
“60227 IEC 53” by “H05 VV-F or H05 VVH2-F2”.
In Table 3B, replace the first four lines by the following:
a)
| Up to and including 6
|
0,75
|
b)
| Over 6 up to and including 10
|
(0,75)
1,0
|
c)
1,5
|
| Over 10 up to and including 16
|
(1,0)
In the conditions applicable to Table 3B delete the words “in some countries” in
a)
condition .
In NOTE 1, applicable to Table 3B, delete the second sentence.
N/A
3.3.4
In Table 3D, delete the fourth line: conductor sizes for 10 to 13 A, and replace with
the following:
| Over 10 up to and including 16 |
1,5 to 2,5
|
1,5 to 4
|
Delete the fifth line: conductor sizes for 13 to 16 A.
N/A
Add the following NOTE:
N/A
4.3.13.6
Result - Remark
NOTE Z1 Attention is drawn to 1999/519/EC: Council Recommendation on the limitation of
exposure of the general public to electromagnetic fields 0 Hz to 300 GHz. Standards taking
into account this Recommendation which demonstrate compliance with the applicable EU
Directive are indicated in the OJEC.
TRF No. IECEN60950_1C
Verdict
Page 35 of 73
Report No. 11021109 001
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Annex H
Replace the last paragraph of this annex by:
At any point 10 cm from the surface of the OPERATOR ACCESS AREA, the dose
rate shall not exceed 1 µSv/h (0,1 mR/h) (see NOTE). Account is taken of the
background level.
Replace the notes as follows:
Verdict
N/A
NOTE These values appear in Directive 96/29/Euratom.
Delete NOTE 2.
Bibliography
Additional EN standards.

ZA
NORMATIVE REFERENCES TO INTERNATIONAL PUBLICATIONS WITH THEIR
CORRESPONDING EUROPEAN PUBLICATIONS

ZB
SPECIAL NATIONAL CONDITIONS
P
1.2.4.1
In Denmark, certain types of Class I appliances (see 3.2.1.1) may be provided with
a plug not establishing earthing conditions when inserted into Danish socket-outlets.
N/A
1.5.7.1
In Finland, Norway and Sweden, resistors bridging BASIC INSULATION in
CLASS I PLUGGABLE EQUIPMENT TYPE A must comply with the requirements in
1.5.7.2.
N/A
1.5.8
In Norway, due to the IT power system used (see annex V, Figure V.7), capacitors
are required to be rated for the applicable line-to-line voltage (230 V).
N/A
1.5.9.4
In Finland, Norway and Sweden, the third dashed sentence is applicable only to
equipment as defined in 6.1.2.2 of this annex.
N/A
1.7.2.1
In Finland, Norway and Sweden, CLASS I PLUGGABLE EQUIPMENT TYPE A
intended for connection to other equipment or a network shall, if safety relies on
connection to protective earth or if surge suppressors are connected between the
network terminals and accessible parts, have a marking stating that the equipment
must be connected to an earthed mains socket-outlet.
The marking text in the applicable countries shall be as follows:
In Finland: "Laite on liitettävä suojamaadoituskoskettimilla varustettuun
pistorasiaan"
In Norway: “Apparatet må tilkoples jordet stikkontakt”
In Sweden: “Apparaten skall anslutas till jordat uttag”
N/A
1.7.5
In Denmark, socket-outlets for providing power to other equipment shall be in
accordance with the Heavy Current Regulations, Section 107-2-D1, Standard Sheet
DK 1-3a, DK 1-5a or DK 1-7a, when used on Class I equipment. For STATIONARY
EQUIPMENT the socket-outlet shall be in accordance with Standard Sheet DK 1-1b
or DK 1-5a.
N/A
2.2.4
In Norway, for requirements see 1.7.2.1, 6.1.2.1 and 6.1.2.2 of this annex.
N/A
2.3.2
In Finland, Norway and Sweden there are additional requirements for the
insulation. See 6.1.2.1 and 6.1.2.2 of this annex.
N/A
2.3.4
In Norway, for requirements see 1.7.2.1, 6.1.2.1 and 6.1.2.2 of this annex.
N/A
TRF No. IECEN60950_1C
Page 36 of 73
Report No. 11021109 001
IEC/EN 60950-1
Clause
Requirement + Test
2.6.3.3
In the United Kingdom, the current rating of the circuit shall be taken as 13 A, not
16 A.
N/A
2.7.1
In the United Kingdom, to protect against excessive currents and short-circuits in
the PRIMARY CIRCUIT of DIRECT PLUG-IN EQUIPMENT, tests according to 5.3
shall be conducted, using an external protective device rated 30 A or 32 A. If these
tests fail, suitable protective devices shall be included as integral parts of the
DIRECT PLUG-IN EQUIPMENT, so that the requirements of 5.3 are met.
N/A
2.10.5.13
In Finland, Norway and Sweden, there are additional requirements for the
insulation, see 6.1.2.1 and 6.1.2.2 of this annex.
N/A
3.2.1.1
In Switzerland, supply cords of equipment having a RATED CURRENT not
exceeding 10 A shall be provided with a plug complying with SEV 1011 or IEC
60884-1 and one of the following dimension sheets:
SEV 6532-2.1991
Plug Type 15 3P+N+PE
250/400 V, 10 A
SEV 6533-2.1991
Plug Type 11 L+N
250 V, 10 A
SEV 6534-2.1991
Plug Type 12 L+N+PE
250 V, 10 A
In general, EN 60309 applies for plugs for currents exceeding 10 A. However, a 16
A plug and socket-outlet system is being introduced in Switzerland, the plugs of
which are according to the following dimension sheets, published in February 1998:
SEV 5932-2.1998
Plug Type 25 3L+N+PE
230/400 V, 16 A
SEV 5933-2.1998
Plug Type 21 L+N
250 V, 16 A
SEV 5934-2.1998
Plug Type 23 L+N+PE
250 V, 16 A
N/A
3.2.1.1
In Denmark, supply cords of single-phase equipment having a rated current not
exceeding13 A shall be provided with a plug according to the Heavy Current
Regulations, Section 107-2-D1.
CLASS I EQUIPMENT provided with socket-outlets with earth contacts or which are
intended to be used in locations where protection against indirect contact is
required according to the wiring rules shall be provided with a plug in accordance
with standard sheet DK 2-1a or DK 2-5a.
If poly-phase equipment and single-phase equipment having a RATED CURRENT
exceeding 13 A is provided with a supply cord with a plug, this plug shall be in
accordance with the Heavy Current Regulations, Section 107-2-D1 or EN 60309-2.
N/A
3.2.1.1
In Spain, supply cords of single-phase equipment having a rated current not
exceeding 10 A shall be provided with a plug according to UNE 20315:1994.
Supply cords of single-phase equipment having a rated current not exceeding 2,5 A
shall be provided with a plug according to UNE-EN 50075:1993.
CLASS I EQUIPMENT provided with socket-outlets with earth contacts or which are
intended to be used in locations where protection against indirect contact is
required according to the wiring rules, shall be provided with a plug in accordance
with standard UNE 20315:1994.
If poly-phase equipment is provided with a supply cord with a plug, this plug shall be
in accordance with UNE-EN 60309-2.
N/A
TRF No. IECEN60950_1C
Result - Remark
Verdict
Page 37 of 73
Report No. 11021109 001
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
3.2.1.1
In the United Kingdom, apparatus which is fitted with a flexible cable or cord and is
designed to be connected to a mains socket conforming to BS 1363 by means of
that flexible cable or cord and plug, shall be fitted with a ‘standard plug’ in
accordance with Statutory Instrument 1768:1994 - The Plugs and Sockets etc.
(Safety) Regulations 1994, unless exempted by those regulations.
N/A
NOTE ‘Standard plug’ is defined in SI 1768:1994 and essentially means an approved plug
conforming to BS 1363 or an approved conversion plug.
3.2.1.1
In Ireland, apparatus which is fitted with a flexible cable or cord and is designed to
be connected to a mains socket conforming to I.S. 411 by means of that flexible
cable or cord and plug, shall be fitted with a 13 A plug in accordance with Statutory
Instrument 525:1997 - National Standards Authority of Ireland (section 28) (13 A
Plugs and Conversion Adaptors for Domestic Use) Regulations 1997.
N/A
3.2.4
In Switzerland, for requirements see 3.2.1.1 of this annex.
N/A
2
3.2.5.1
In the United Kingdom, a power supply cord with conductor of 1,25 mm is allowed
for equipment with a rated current over 10 A and up to and including 13 A.
N/A
3.3.4
In the United Kingdom, the range of conductor sizes of flexible cords to be
accepted by terminals for equipment with a RATED CURRENT of over 10 A up to
and including 13 A is:
2
2
• 1,25 mm to 1,5 mm nominal cross-sectional area.
N/A
4.3.6
In the United Kingdom, the torque test is performed using a socket outlet
complying with BS 1363 part 1:1995, including Amendment 1:1997 and Amendment
2:2003 and the plug part of DIRECT PLUG-IN EQUIPMENT shall be assessed to
BS 1363: Part 1, 12.1, 12.2, 12.3, 12.9, 12.11, 12.12, 12.13, 12.16 and 12.17,
except that the test of 12.17 is performed at not less than 125 °C. Where the metal
earth pin is replaced by an Insulated Shutter Opening Device (ISOD), the
requirements of clauses 22.2 and 23 also apply.
N/A
4.3.6
In Ireland, DIRECT PLUG-IN EQUIPMENT is known as plug similar devices. Such
devices shall comply with Statutory Instrument 526:1997 - National Standards
Authority of Ireland (Section 28) (Electrical plugs, plug similar devices and sockets
for domestic use) Regulations, 1997.
N/A
5.1.7.1
In Finland, Norway and Sweden TOUCH CURRENT measurement results
exceeding 3,5 mA r.m.s. are permitted only for the following equipment:
• STATIONARY PLUGGABLE EQUIPMENT TYPE A that
is intended to be used in a RESTRICTED ACCESS LOCATION where
equipotential bonding has been applied, for example, in a
telecommunication centre; and
has provision for a permanently connected PROTECTIVE EARTHING
CONDUCTOR; and
is provided with instructions for the installation of that conductor by a
SERVICE PERSON;
• STATIONARY PLUGGABLE EQUIPMENT TYPE B;
• STATIONARY PERMANENTLY CONNECTED EQUIPMENT.
N/A
TRF No. IECEN60950_1C
Page 38 of 73
Report No. 11021109 001
IEC/EN 60950-1
Clause
Requirement + Test
6.1.2.1
In Finland, Norway and Sweden, add the following text between the first and
second paragraph of the compliance clause:
If this insulation is solid, including insulation forming part of a component, it shall at
least consist of either
two layers of thin sheet material, each of which shall pass the electric
strength test below, or
one layer having a distance through insulation of at least 0,4 mm, which
shall pass the electric strength test below.
If this insulation forms part of a semiconductor component (e.g. an optocoupler),
there is no distance through insulation requirement for the insulation consisting of
an insulating compound completely filling the casing, so that CLEARANCES and
CREEPAGE DISTANCES do not exist, if the component passes the electric
strength test in accordance with the compliance clause below and in addition
passes the tests and inspection criteria of 2.10.11 with an electric strength
test of 1,5 kV multiplied by 1,6 (the electric strength test of 2.10.10 shall be
performed using 1,5 kV), and
is subject to ROUTINE TESTING for electric strength during manufacturing,
using a test voltage of 1,5 kV.
It is permitted to bridge this insulation with a capacitor complying with
EN 132400:1994, subclass Y2.
A capacitor classified Y3 according to EN 132400:1994, may bridge this insulation
under the following conditions:
the insulation requirements are satisfied by having a capacitor classified Y3
as defined by EN 132400, which in addition to the Y3 testing, is tested with
an impulse test of 2,5 kV defined in EN 60950-1:2006, 6.2.2.1;
the additional testing shall be performed on all the test specimens as
described in EN 132400;
the impulse test of 2,5 kV is to be performed before the endurance test in
EN 132400, in the sequence of tests as described in EN 132400.
N/A
6.1.2.2
In Finland, Norway and Sweden, the exclusions are applicable for
PERMANENTLY CONNECTED EQUIPMENT, PLUGGABLE EQUIPMENT TYPE B
and equipment intended to be used in a RESTRICTED ACCESS LOCATION where
equipotential bonding has been applied, e.g. in a telecommunication centre, and
which has provision for a permanently connected PROTECTIVE EARTHING
CONDUCTOR and is provided with instructions for the installation of that conductor
by a SERVICE PERSON.
N/A
7.2
In Finland, Norway and Sweden, for requirements see 6.1.2.1 and 6.1.2.2 of this
annex.
The term TELECOMMUNICATION NETWORK in 6.1.2 being replaced by the term
CABLE DISTRIBUTION SYSTEM.
N/A
7.3
In Norway and Sweden, there are many buildings where the screen of the coaxial
cable is normally not connected to the earth in the building installation.
N/A
7.3
In Norway, for installation conditions see EN 60728-11:2005.
N/A
ZC
A-DEVIATIONS (informative)
TRF No. IECEN60950_1C
Result - Remark
Verdict
P
Page 39 of 73
Report No. 11021109 001
IEC/EN 60950-1
Clause
Requirement + Test
1.5.1
Sweden (Ordinance 1990:944)
Add the following:
Result - Remark
Verdict
N/A
NOTE In Sweden, switches containing mercury are not permitted.
1.5.1
Switzerland (Ordinance on environmentally hazardous substances SR 814.081,
Annex 1.7, Mercury - Annex 1.7 of SR 814.81 applies for mercury.)
Add the following:
N/A
NOTE In Switzerland, switches containing mercury such as thermostats, relays and level
controllers are not allowed.
1.7.2.1
Denmark (Heavy Current Regulations)
Supply cords of CLASS I EQUIPMENT, which is delivered without a plug, must be
provided with a visible tag with the following text:
Vigtigt!
Lederen med grøn/gul isolation
må kun tilsluttes en klemme mærket
N/A
eller
If essential for the safety of the equipment, the tag must in addition be provided with
a diagram, which shows the connection of the other conductors, or be provided with
the following text:
“For tilslutning af de øvrige ledere, se medfølgende installationsvejledning.”
1.7.2.1
Germany (Gesetz über technische Arbeitsmittel und Verbraucherprodukte (Geräteund Produktsicherheitsgesetz – GPSG) [Law on technical labour equipment and
consumer products], of 6th January 2004, Section 2, Article 4, Clause (4), Item 2).
If for the assurance of safety and health certain rules during use, amending or
maintenance of a technical labour equipment or readymade consumer product are
to be followed, a manual in German language has to be delivered when placing the
product on the market.
Of this requirement, rules for use even only by SERVICE PERSONS are not
exempted.
N/A
1.7.5
Denmark (Heavy Current Regulations)
With the exception of CLASS II EQUIPMENT provided with a socket outlet in
accordance with the Heavy Current Regulations, Section 107-2-D1, Standard Sheet
DK 1-4a, CLASS II EQUIPMENT shall not be fitted with socket-outlets for providing
power to other equipment.
N/A
1.7.13
Switzerland (Ordinance on chemical hazardous risk reduction SR 814.81, Annex
2.15 Batteries)
Annex 2.15 of SR 814.81 applies for batteries.
N/A
5.1.7.1
Denmark (Heavy Current Regulations, Chapter 707, clause 707.4)
TOUCH CURRENT measurement results exceeding 3,5 mA r.m.s. are permitted
only for PERMANENTLY CONNECTED EQUIPMENT and PLUGGABLE
EQUIPMENT TYPE B.
N/A
TRF No. IECEN60950_1C
Page 40 of 73
Report No. 11021109 001
IEC/EN 60950-1
Clause
Requirement + Test
1.5.1
TABLE: List of critical components
Object/part no.
Manufacturer/
trademark
Result - Remark
Verdict
P
Type/model
Technical data
Standard
Mark(s) of
1.
conformity
V173
I/P: 100-240Vac,
50-60Hz, 1.5A.
O/P: 19Vdc, 3.42A,
40ºC, Class I
EN 609501/A11: 2001
IEC 60950-1:
2001
UL 60950-1
TÜV, UL,
CB by TÜV
Lite-On
PA-1650-68
I/P: 100-240Vac,
50-60Hz, 2.0A.
O/P: 19Vdc, 3.42A,
40ºC, Class I
EN 609501/A11: 2001
IEC 60950-1:
2001
UL 60950-1
TÜV, UL,
CB by TÜV
Lite-On
PA-1650-65
I/P: 100-240Vac,
IEC 60950-1:
50-60Hz, 2.0A.
2001
O/P: 19Vdc, 3.42A, UL 60950-1
40ºC, Class II
UL,
CB by Nemko
FSP
FSP065-RAB
I/P: 100-240Vac,
50-60Hz, 1.5A.
O/P: 19Vdc, 3.42A,
40ºC, Class I
EN 60950-1:
2001+A11
IEC 60950-1:
2001
UL 60950-1
TÜV, UL,
CB by TÜV
(For input rating: Hipro
18.5Vdc, 3.5A) (Chicony Power
Technology Co
Ltd)
HP-OK065B13
I/P: 100-240Vac,
50-60Hz, 1.7A.
O/P: 18.5Vdc,
3.5A, 40ºC,
Class I
EN 609501:2001
IEC 60950-1:
2001
UL 60950-1
TÜV, UL,
CB by Nemko
LCD Panel
(LED backlight)
AUO
B156HW01
15.6" TFT
--
--
AUO
B156XW02
15.6" TFT
--
--
AUO
B156RW01
15.6" TFT
--
--
LG
LP156WH2
15.6" TFT
--
--
LG
LP156WD1
15.6" TFT
--
--
LG
LP156WF1
15.6" TFT
--
--
CHI MEI
N156B6-L02
15.6" TFT
--
--
CHI MEI
N156B6-L05
15.6" TFT
--
--
CHI MEI
N156B6-L06
15.6" TFT
--
--
CHI MEI
N156B6-L03
15.6" TFT
--
--
INNOLUX
BT156GW01
15.6" TFT
--
--
INNOLUX
BT156GW02
15.6" TFT
--
--
Chi Mei
N156B3-L02
15.6” TFT
--
--
Power Adaptor Darfon
(For input rating:
19Vdc, 3.42A)
LCD Panel
TRF No. IECEN60950_1C
Page 41 of 73
Report No. 11021109 001
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
HDD
(Optional)
Toshiba
or equivalent
HDD2yyyx
5Vdc, 1.1A max.
(x=A-Z, y=0-9 or
A-Z)
or equivalent
EN 609501:2001
IEC 609501:2001
TÜV, UL
CD-RW/DVD
Drive
(Optional)
Toshiba
Samsung
or equivalent
TS-L463
or equivalent
5Vdc, 1.3A max.
Laser Class 1
Bezel min. 1mm
thick, rated min. V1
EN 608251:1994+A1+A2
EN 609501:2001+A11
IEC 608251:1993+A1+A2
IEC 609501:2001
UL 60950-1
TÜV, UL
DVD Writer
(Optional)
Toshiba
Samsung
or equivalent
TS-L633
or equivalent
5Vdc, 1.3A or 1.5A
max.
Laser Class 1
Bezel min. 1mm
thick, rated min. V1
EN 608251:1994+A1+A2
EN 609501:2001+A11
IEC 608251:1993+A1+A2
IEC 609501:2001
UL 60950-1
TÜV, UL
Toshiba
Samsung
or equivalent
TS-L632
or equivalent
5Vdc, 1.5A max.
Laser Class 1
Bezel min. 1mm
thick, rated min. V1
EN 608251:1994+A1+A2
EN 609501:2001
IEC 608251:1993+A1+A2
IEC 609501:2001
UL 60950-1
TÜV, UL
Toshiba
Samsung
or equivalent
TS-U633
or equivalent
5Vdc, 1.3A max.
Laser Class 1
Bezel min. 1mm
thick, rated min. V1
EN 608251:1994+A1+A2
EN 609501:2001+A11
IEC 608251:1993+A1+A2
IEC 609501:2001
UL 60950-1
TÜV, UL
Hitachi-LG
or equivalent
CT10N
or equivalent
5Vdc, 1.5A max.
Laser Class 1
Bezel min. 1mm
thick, rated min. V1
EN 608251/A2:2001
EN 609501/A11:2004
IEC 608251:1993+A1+A2
IEC 609501:2001
UL 60950-1
TÜV, UL
BD-Rom/DVD
Rewriter
(Optional)
TRF No. IECEN60950_1C
Page 42 of 73
Report No. 11021109 001
IEC/EN 60950-1
Clause
Requirement + Test
Super Multi
DVD Rewriter
(Optional)
Blu-ray Disc
Drive
(Optional)
Result - Remark
Verdict
Hitachi-LG
or equivalent
CT21N
or equivalent
5Vdc, 1.5A max.
Laser Class 1
Bezel min. 1mm
thick, rated min. V1
EN 608251/A2:2001
EN 609501:2006
IEC 608251:1993+A1+A2
IEC 609501:2005
UL 60950-1
TÜV, UL
Hitachi-LG
or equivalent
GSA-T50N
or equivalent
5Vdc, 1.5A max.
Laser Class 1
Bezel min. 1mm
thick, rated min. V1
EN 608251/A2:2001
EN 609501/A11:2004
IEC 608251:1993+A1+A2
IEC 609501:2001
UL 60950-1
TÜV, UL
Hitachi-LG
or equivalent
GT3** (first “*”
can be any
number 0-9 and
second “*” can
be any
alphanumeric
character)
or equivalent
5Vdc, 1.8A max.
Laser Class 1
Bezel min. 1mm
thick, rated min. V1
EN 60825TÜV,
1:1994 + A1+A2 CB by Intertek,
UL
EN 609501:2006
IEC 608251:1993+A1+A2
IEC 609501:2005
UL 60950-1
Hitachi-LG
or equivalent
GT10N
or equivalent
5Vdc, 1.8A max.
Laser Class 1
Bezel min. 1mm
thick, rated min. V1
EN 608251/A2:2001
EN 609501/A11:2004
IEC 608251:1993 and
A1+A2
IEC 609501:2001
UL 60950-1
TÜV,
CB by Intertek,
UL
Panasonic
or equivalent
UJ130A or
UJ130E
or equivalent
5Vdc, 1.6A max.
Laser Class 1
Bezel min. 1mm
thick, rated min. V1
EN 608251:1994+A1+A2
EN 609501:2006
IEC 608251:1993+A1+A2
IEC 609501:2005
UL 60950-1
TÜV,
CB by TÜV,
UL
TRF No. IECEN60950_1C
Page 43 of 73
Report No. 11021109 001
IEC/EN 60950-1
Clause
Requirement + Test
DVD MULTI
DRIVE
(Optional)
Result - Remark
Verdict
Panasonic
or equivalent
UJ880A
or equivalent
5Vdc, 1.6A max.
Laser Class 1
Bezel min. 1mm
thick, rated min. V1
EN 608251:1994+A1+A2
EN 609501:2001+A11
IEC 608251:1993+A1+A2
IEC 609501:2001
UL 60950-1
TÜV,
CB by TÜV,
UL
Panasonic
or equivalent
UJ892
or equivalent
5Vdc, 1.6A max.
Laser Class 1
Bezel min. 1mm
thick, rated min. V1
EN 608251:1994+A1+A2
EN 609501:2001+A11
IEC 608251:1993+A1+A2
IEC 609501:2001
UL 60950-1
TÜV,
CB by TÜV,
UL
DVD/CD
Philips & Lite-On
Rewritable drive or equivalent
(Optional)
DS-xx3Sxxx (x
can be any
alphanumeric or
blank)
or equivalent
5Vdc, 1.5A max.
Laser Class 1
Bezel min. 1mm
thick, rated min. V1
EN 608251:1994+A1+A2
EN 609501:2001+A11
IEC 608251:1993+A1+A2
IEC 609501:2001
UL 60950-1
TÜV,
CB by TÜV,
UL
Philips & Lite-On
or equivalent
DS-xx4Sxxx (x
can be any
alphanumeric or
blank)
or equivalent
5Vdc, 1.5A max.
Laser Class 1
Bezel min. 1mm
thick, rated min. V1
EN 608251:2007
EN 609501:2006+A11
IEC 608251:2007
IEC 609501:2005
UL 60950-1
TÜV,
CB by TÜV,
UL
Sony Optiarc
or equivalent
AD-X58XSXXX
(X=0-9, A-Z, “-”
or blank)
or equivalent
5Vdc, 1.5A max.
Laser Class 1
Bezel min. 1mm
thick, rated min. V1
EN 608251:1994+A1+A2
EN 609501:2001+A11
IEC 608251:1993+A1+A2
IEC 609501:2001
TÜV, UL
DVD/CD
REWRITABLE
DRIVE
(Optional)
TRF No. IECEN60950_1C
Page 44 of 73
Report No. 11021109 001
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
Philips & Lite-On
or equivalent
DS-xx5Sxxxxx
(x can be any
alphanumeric or
blank) or
equivalent
5Vdc, 1.5A max.
Laser Class 1
Bezel min. 1mm
thick, rated min. V1
EN 608251:2007
EN 60950-1:
2006+A11
IEC 60825-1:
2005
IEC 609501:2005
UL 60950-1
TÜV, UL,
CB by TÜV
BD COMBO
DRIVE
(Optional)
Philips & Lite-On
or equivalent
DS-4E1S
or equivalent
5Vdc, 1.5A max.
Laser Class 1
Bezel min. 1mm
thick, rated min. V1
EN 608251:1994+A1+A2
EN 609501:2001+A11
IEC 608251:1993+A1+A2
IEC 609501:2001
UL 60950-1
TÜV, UL
BD/DVD/CD
Writer Unit
(Optional)
Pioneer
or equivalent
BDRTD01xxxxy,
BDCTD01xxxxy
(x=A-Z, “-“ or
blank; y=0-9, AZ, “-“ or blank)
or equivalent
5Vdc, 1.6A max.
Laser Class 1
Bezel min. 1mm
thick, rated min. V1
EN 608251:1994+A1+A2
EN 609501:2006
IEC 608251:1993+A1+A2
IEC 609501:2005
UL 60950-1
TÜV,
CB by TÜV,
UL
RTC Battery
(J_RTC1)
Mitsubishi
CR2032
Maximum
abnormal charge
current 10mA.
UL 1642
UL
Double Best
CR2032
Max. abnormal
charge current
10mA
UL 1642
UL
VIC-DAWN
CR2032
Max. abnormal
charge current
10mA
UL 1642
UL
Motorola
ML3054
3.3Vdc, 20mA
max.
EN 609501/A11: 2004
IEC 60950-1:
2001
UL 60950-1
TÜV, UL
CB by TÜV
--
V-2 or better,
0.07mm thick
each, one or two
layers
UL 94
UL
Modem Card
(Optional)
- Insulation
-Sheet of Modem
Card
TRF No. IECEN60950_1C
Page 45 of 73
Report No. 11021109 001
IEC/EN 60950-1
Clause
Requirement + Test
Modem Card
(Optional)
Verdict
D40 (D40 AM5) 3.3Vdc, 35mA
EN 609501/A11: 2004
IEC 60950-1:
2001
UL 60950-1
TÜV, UL
CB by TÜV
- Insulation
-Sheet of Modem
Card
--
UL 94
UL
DC Fan
(One provided)
ADDA
AB6505HX-J03 5Vdc, 0.4A.,
4.65CFM min.
EN 60950-1:
2001+A11
IEC 60950-1:
2001
UL 507
TÜV, UL
A-POWER
BS5005HS-U89 5Vdc, 0.5A.,
4.45CFM min.
EN 60950-1:
2001+A11
IEC 60950-1:
2001
UL 507
TÜV, UL
Mitac
M660JEINT-D
I/P: 20Vdc
-maximum, 700mA
maximum.
O/P: 1900Vrms
maximum, 6.5mA
maximum.
--
- DC/AC
Yao Sheng
Inverter
transformer (T1)
273001050293
105ºC min.
--
--
DC/AC Inverter
(Optional)
M660SRUINT-E I/P: 20Vdc
maximum. 320mA
maximum.
O/P: 1900Vrms
maximum, 6.5mA
maximum.
--
--
- DC/AC
Taiwan Sumida
Inverter
transformer (T1)
CIUH8D37T
105ºC min.
--
--
Speakers
(Two provided)
--
--
8ohm, 1.5W
--
--
PCB
--
--
V-1 min., 105ºC
min.
UL 796
UL
Plastic
Enclosure
Sabic
CM6140
V-0 minimum, 1.5
mm thick
minimum.
UL 94
UL
Sabic
C7230P
V-0 min. 1.2 mm
thick min.
UL 94
UL
DC/AC Inverter
(Optional)
Agere
Result - Remark
Taiwan Sumida
TRF No. IECEN60950_1C
V-2 or better,
0.07mm thick
each, one or two
layers
Page 46 of 73
Report No. 11021109 001
IEC/EN 60950-1
Clause
Requirement + Test
Battery Pack
Result - Remark
Verdict
Teijin Chemicals TN-3715B
Ltd Research &
Development Div
V-1 min. 1.0 mm
thick min.
UL 94
UL
Simplo
M660NBAT-6
SIMPLO
10.8Vdc or
11.1Vdc,
4800mAh/51.84W
h or 53.28Wh;
4400mAh/47.52W
h or 48.84Wh;
4000mAh/43.2Wh
or 44.4Wh,
45ºC
EN 609501/A11: 2009
IEC 60950-1:
2005
UL 60950-1,
UL 2054
TÜV, UL
Simplo
SQU-601
SIMPLO
10.8Vdc,
7200mAh 77.76Wh
or 11.1Vdc,
7200mAh/79.92Wh
, 45ºC
EN 609501/A11: 2009
IEC 60950-1:
2005
UL 60950-1,
UL 2054
TÜV, UL
Gallopwire
M660BAT-6
10.8Vdc,
4400mAh,
47.52Wh, 45ºC
EN 609501/A11: 2009
IEC 60950-1:
2005
UL 60950-1,
UL 2054
TÜV, UL
Supplementary information:
1. An asterisk indicates a mark that assures the agreed level of surveillance.
1.6.2
U (V)
TABLE: Electrical data (in normal conditions)
I (A)
Irated (A)
P (W)
Fuse #
P
Ifuse (A)
Condition/status
For unit w/o DC/AC inverter:
Test with CPU source by Intel® Core i7-620M Processor, speed 2.66GHz
DC 19
3.35
3.42
63.7
--
--
Maximum normal load with battery
charging mode.
Test with CPU source by Intel® Core i5-540M Processor, speed 2.53GHz
DC 19
3.24
3.42
61.6
--
--
Maximum normal load with battery
charging mode.
Test with CPU source by Intel® Core i3-350M Processor, speed 2.27GHz
DC 19
3.06
3.42
58.1
--
--
Maximum normal load with battery
charging mode.
Test with CPU source by Intel® Celeron P4500 Processor, speed 1.86GHz
DC 19
3.23
TRF No. IECEN60950_1C
3.42
61.4
--
--
Maximum normal load with battery
charging mode.
Page 47 of 73
Report No. 11021109 001
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
Test with CPU source by Intel® Core i7-620M Processor, speed 2.66GHz
DC 18.5
3.43
3.5
63.5
--
--
Maximum normal load with battery
charging mode.
For unit with DC/AC inverter by Taiwan Sumida / M660SRUINT-E
Test with CPU source by Intel® Core i7-620M Processor, speed 2.66GHz
DC 18.5
3.48
3.5
64.4
--
--
Maximum normal load with battery
charging mode.
For unit with DC/AC inverter by Mitac / M660JEINT-D
Test with CPU source by Intel® Core i7-620M Processor, speed 2.66GHz
DC 18.5
3.48
3.5
64.4
--
--
Maximum normal load with battery
charging mode.
Supplementary information:
1. Test is equipped with battery pack by SQU-601 SIMPLO with 7200mAh
2.10.3 and TABLE: Clearance and creepage distance measurements
2.10.4
P
Clearance (cl) and creepage
distance (cr) at/of/between:
U peak
(V)
U r.m.s.
(V)
Required
cl (mm)
cl
(mm)
Required
cr (mm)
cr
(mm)
TNV-3 circuit traces to SELV
circuit trace
140
125
1.0
See below
1.5
See below
MJ_MODEM1 to MJ_SPK1
140
125
1.0
3.0
1.5
3.0
ML5 to SELV trace
140
125
1.0
3.0
1.5
3.0
Supplementary information:
1. Functional insulation shorted, see sub-clause 5.3.4.
2. The insulation distances between primary and secondary are keep in approved power adaptor only.
3. The modem module Motorola / ML3054 was covered completely by one layer of thin insulation sheet at
least.
4. The modem module Agere / D40 (D40 AM5) was covered completely by one layer of thin insulation sheet
at least.
2.10.5
TABLE: Distance through insulation measurements
Distance through insulation (DTI) at/of:
Supplementary information:
TRF No. IECEN60950_1C
U peak
(V)
U r.m.s.
(V)
N/A
Test
voltage
(V)
Required
DTI
(mm)
DTI
(mm)
Page 48 of 73
Report No. 11021109 001
IEC/EN 60950-1
Clause
Requirement + Test
4.3.8
TABLE: Batteries
Result - Remark
Verdict
P
The tests of 4.3.8 are applicable only when appropriate battery
data is not available
See below.
P
Is it possible to install the battery in a reverse polarity position?
1.
P
Non-rechargeable batteries
Discharging
Meas.
current
Manuf.
Specs.
Unintentional
charging
Rechargeable batteries
Charging
Discharging
Reversed charging
Meas.
current
Manuf.
Specs.
Meas.
current
Manuf.
Specs.
Meas.
current
Manuf.
Specs.
--
--
--
--
--
--
12.6V/
3.08A
4.3A
6A
--
1.
--
1.
12.6V/
3.08A
--
--
--
1.
--
1.
12.6V/
3.4A
4.3A
4.8A
--
1.
--
1.
12.6V/
3.4A
--
--
--
1.
--
1.
12.6V/
4.4A
4.3A
4.4A
--
1.
--
1.
12.6V/
4.4A
--
--
--
1.
--
1.
For RTC battery:
Max.
current
during
fault
condition
--
--
--
2.
For battery pack by Simplo / M660NBAT-6 SIMPLO:
Max.
current
during
normal
condition
--
--
--
Max.
current
during
fault
condition
--
--
--
12.58V
2.98A
--
2.
For battery pack by Simplo / SQU-601 SIMPLO:
Max.
current
during
normal
condition
--
--
--
Max.
current
during
fault
condition
--
--
--
12.58V
2.98A
--
2.
For battery pack by Gallopwire / M660BAT-6:
Max.
current
during
normal
condition
--
--
--
Max.
current
during
fault
condition
--
--
--
TRF No. IECEN60950_1C
12.58V
2.98A
--
2.
Page 49 of 73
Report No. 11021109 001
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
Test results:
Verdict
- Chemical leaks
No such results occurred.
P
- Explosion of the battery
No such results occurred.
P
- Emission of flame or expulsion of molten metal
No such results occurred.
P
- Electric strength tests of equipment after completion of tests
N/A
Supplementary information:
1. No reverse charging is likely due to the construction design.
2. See appended table 5.3.
4.5
TABLE: Thermal requirements
P
Supply voltage (V) ........................................: A). DC 18.5V with battery charging
mode

B). Power from battery discharging
mode
Ambient Tmin (°C) ..........................................: --

Ambient Tmax (°C) .........................................: --

Maximum measured temperature T of part/at::
Test Voltage:
T (°C)
Allowed
Tmax (°C)
A)
B)
--
PCB near U16 (CPU)
59.2
56.8
105
PCB near U26
53.6
53.2
105
PCB near U27
45.6
46.5
105
RTC Battery
50.7
49.1
--
PCB near U2 (DC/AC Inverter)
60.8
61.2
105
T1 coil (DC/AC Inverter)
78.3
76.2
105
ODD
42.8
43.3
--
HDD
46.9
45.3
--
Enclosure inside, near U16 (CPU)
45.2
46.2
--
Enclosure outside, near U16 (CPU)
43.2
45.2
75
Enclosure inside, near T1 of DC/AC Inverter
55.7
62.1
--
Enclosure outside, near T1 of DC/AC Inverter
51.8
54.5
75
Enclosure inside, near battery pack
40.8
54.4
--
Enclosure outside, near battery pack
38.4
53.6
75
Tamb
25.7
25.5
--
Tma
35.0
35.0
--
Test with DC/AC Inverter: Mitac / M660JEINT-D
TRF No. IECEN60950_1C
Page 50 of 73
Report No. 11021109 001
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
Test with DC/AC Inverter: Taiwan Sumida / M660SRUINT-E
PCB near U3 (DC/AC Inverter)
59.9
59.5
105
T1 coil (DC/AC Inverter)
76.3
74.9
105
Tamb
25.7
25.5
--
Tma
35.0
35.0
--
Supplementary information:
1. The temperatures were measured under worst case normal mode defined in 1.2.2.1 and as described in
1.6.2 at voltages as above.
2. The maximum ambient temperature (Tma) permitted by the manufacturer’s specification is 35 °C.
3. All values for T (°C) are re-calculated from Tamb respectively.
4. The CPU source by Intel® Core i7-620M Processor, speed 2.66GHz and battery pack by SQU-601
SIMPLO with 7200mAh during the test.
Temperature T of winding:
t1 (°C)
R1 (Ω)
t2 (°C)
R2 (Ω)
T (°C)
Allowed Insulation
Tmax (°C)
class
Supplementary information:
4.5.5
TABLE: Ball pressure test of thermoplastic parts
N/A
Allowed impression diameter (mm) ..................: ≤ 2 mm
Part

Test temperature
(°C)
Impression diameter
(mm)
Supplementary information:
4.7
Table: Resistance to fire
Part
Manufacturer of
material
P
Type of material
Thickness
(mm)
Flammability
class
Evidence
Supplementary information:
See appended table 1.5.1 for details.
5.2
TABLE: Electric strength tests, impulse tests and voltage surge tests
Test voltage applied between:
Voltage shape
(AC, DC,
impulse, surge)
P
Test voltage
(V)
Breakdown
Yes / No
1500
No
Tests with modem card Motorola / ML3054 and Agere / D40 (D40 AM5)
TNV-3 to keyboard
TRF No. IECEN60950_1C
AC
Page 51 of 73
Report No. 11021109 001
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TNV-3 to entire exterior enclosure with metal foil
AC
1500
No
TNV-3 to SELV output ports
AC
1500
No
Supplementary information:
5.3
TABLE: Fault condition tests
P
Ambient temperature (°C) ..................................... : See below.

Power source for EUT: Manufacturer, model/type, See appended table 1.5.1.
output rating ........................................................... :

Component
No.
Fault
Supply
voltage
(V)
Test
time
Fuse #
Fuse
current
(A)
Observation
CPU Fan
Stalled
DC 18.5
1h
--
--
Unit shut down. The max. temp.
of T1 coil of inverter= 69°C,
Tamb = 26.2°C. No damage, no
hazard.
Ventilation
Openings
Blocked
DC 18.5
2.5 h
--
--
Unit shut down. The max. temp.
of T1 coil of inverter= 71.6°C,
Tamb = 26.7°C. No damage, no
hazard.
D128
s-c
DC 19
10 min
--
--
The reverse current is measured
as 2.9mA, no hazard.
R327
s-c
DC 19
10 min
--
--
The reverse current is measured
as 0mA, no hazard.
For RTC battery:
The charging circuit for Battery Pack:
PR129
(Overcharge)
s-c
--
--
--
--
Maximum charge voltage and
current is 12.6V/0.4A and is
operated within the rating of
certified battery pack.
PQ16A (1,2 to
7)
(Overcharge)
s-c
--
--
--
--
Maximum charge voltage and
current is 12.6V/0A and is
operated within the rating of
certified battery pack.
PR135
(Overcharge)
s-c
--
--
--
--
Maximum charge voltage and
current is 12.6V/0A and is
operated within the rating of
certified battery pack.
Supplementary information:
Use abbreviations: s-c=short-circuited.
TRF No. IECEN60950_1C
Page 52 of 73
Report No. 11021109 001
List of test equipment used:
Clause
Measurement /
testing
Testing / measuring equipment /
material used
Supplementary information:
No listing of test equipment used necessary for chosen test procedure.
TRF No. IECEN60950_1C
Range used
Calibration
date
ATTACHMENT
Measurement Section
Page 53 of 73
Clause
Requirement + Test
2.1.1.5
TABLE: Energy hazard measurement
Voltage (rated)
(V)
Report No.:
11021109 001
Result - Remark
Current (rated)
(A)
Verdict
N/A
Voltage (max.)
(V)
Current (max.)
(A)
VA (max.)
(VA)
Supplementary information:
2.1.1.7
TABLE: Discharge test
Condition
N/A
τ calculated τ measured
(s)
(s)
t u→ 0V
(s)
Comments
Supplementary information:
2.2.2
TABLE: SELV measurement (under normal conditions)
Transformer
Location
N/A
Voltage (max.) (V)
V peak
V d.c.
Voltage Limitation
Component
Supplementary information:
2.2.3
TABLE: SELV measurement (under fault conditions)
Location
Voltage (max.) (V)
N/A
Comments
Supplementary information:
2.4.2
TABLE: Limited current circuit measurement
Location
Voltage
(V)
Current
(mA)
P
Freq.
(kHz)
Limit
(mA)
Comments
For DC/AC Inverter: MITAC, type M660JEINT-D
Normal condition
CN2 pin1 to pin2
0
0
--
--
Unit shut down immediately.
CN2 pin1 to earth
0
0
--
--
Unit shut down immediately.
CN2 pin2 to earth
3.48
1.74
55
38.5
T1 pin3 to pin4
0
0
--
--
Unit shut down immediately.
T1 pin4 to earth
0
0
--
--
Unit shut down immediately.
T1 pin3 to earth
1.4
0.7
55
38.5
Single fault: C4 shorted
Rev. 0
ATTACHMENT
Measurement Section
Page 54 of 73
Clause
Requirement + Test
Report No.:
Result - Remark
11021109 001
Verdict
CN2 pin1 to pin2
0
0
--
--
Unit shut down immediately.
CN2 pin1 to earth
0
0
--
--
Unit shut down immediately.
CN2 pin2 to earth
4.04
2.02
55
38.5
T1 pin3 to pin4
0
0
--
--
Unit shut down immediately.
T1 pin4 to earth
0
0
--
--
Unit shut down immediately.
T1 pin3 to earth
1.68
0.84
55
38.5
CN2 pin1 to pin2
0
0
--
--
Unit shut down immediately.
CN2 pin1 to earth
0
0
--
--
Unit shut down immediately.
CN2 pin2 to earth
3.88
1.94
55
38.5
T1 pin3 to pin4
0
0
--
--
Unit shut down immediately.
T1 pin4 to earth
0
0
--
--
Unit shut down immediately.
T1 pin3 to earth
2.66
1.33
55
38.5
Single fault: C3 shorted
Single fault: U1 pin2 to 6 shorted
CN2 pin1 to pin2
0
0
--
--
Unit shut down immediately.
CN2 pin1 to earth
0
0
--
--
Unit shut down immediately.
CN2 pin2 to earth
0
0
--
--
Unit shut down immediately.
T1 pin3 to pin4
0
0
--
--
Unit shut down immediately.
T1 pin4 to earth
0
0
--
--
Unit shut down immediately.
T1 pin3 to earth
0
0
--
--
Unit shut down immediately.
CN2 pin1 to pin2
0
0
--
--
Unit shut down immediately.
CN2 pin1 to earth
0
0
--
--
Unit shut down immediately.
CN2 pin2 to earth
0
0
--
--
Unit shut down immediately.
T1 pin3 to pin4
0
0
--
--
Unit shut down immediately.
T1 pin4 to earth
0
0
--
--
Unit shut down immediately.
T1 pin3 to earth
0
0
--
--
Unit shut down immediately.
CN2 pin1 to pin2
0
0
--
--
Unit shut down immediately.
CN2 pin1 to earth
0
0
--
--
Unit shut down immediately.
CN2 pin2 to earth
3.48
1.74
55
38.5
T1 pin3 to pin4
0
0
--
--
Unit shut down immediately.
T1 pin4 to earth
0
0
--
--
Unit shut down immediately.
T1 pin3 to earth
1.4
0.7
55
38.5
Single fault: R18 shorted
Single fault: R14 shorted
Rev. 0
ATTACHMENT
Measurement Section
Page 55 of 73
Clause
Requirement + Test
Report No.:
Result - Remark
11021109 001
Verdict
Single fault: D2 pin2 to 3 shorted
CN2 pin1 to pin2
0
0
--
--
Unit shut down immediately.
CN2 pin1 to earth
0
0
--
--
Unit shut down immediately.
CN2 pin2 to earth
3.48
1.74
55
38.5
T1 pin3 to pin4
0
0
--
--
Unit shut down immediately.
T1 pin4 to earth
0
0
--
--
Unit shut down immediately.
T1 pin3 to earth
1.4
0.7
55
38.5
For DC/AC Inverter: Taiwan Sumida, type M660SRUINT-E
Normal condition
CN2 pin1 to pin2
0
0
--
--
Unit shut down immediately.
CN2 pin1 to earth
0
0
--
--
Unit shut down immediately.
CN2 pin2 to earth
4.4
2.2
59
41.3
T1 pin4 to pin5
0
0
--
--
Unit shut down immediately.
T1 pin5 to earth
0
0
--
--
Unit shut down immediately.
CN2 pin1 to pin2
0
0
--
--
Unit shut down immediately.
CN2 pin1 to earth
0
0
--
--
Unit shut down immediately.
CN2 pin2 to earth
0
0
--
--
Unit shut down immediately.
T1 pin4 to pin5
0
0
--
--
Unit shut down immediately.
T1 pin5 to earth
0
0
--
--
Unit shut down immediately.
CN2 pin1 to pin2
0
0
--
--
Unit shut down immediately.
CN2 pin1 to earth
0
0
--
--
Unit shut down immediately.
CN2 pin2 to earth
4.4
2.2
60
42.0
T1 pin4 to pin5
0
0
--
--
Unit shut down immediately.
T1 pin5 to earth
0
0
--
--
Unit shut down immediately.
Single fault: C6 shorted
Single fault: C5 shorted
Single fault: U2 pin 2 to 6 shorted
CN2 pin1 to pin2
0
0
--
--
Unit shut down immediately.
CN2 pin1 to earth
0
0
--
--
Unit shut down immediately.
CN2 pin2 to earth
0
0
--
--
Unit shut down immediately.
T1 pin4 to pin5
0
0
--
--
Unit shut down immediately.
T1 pin5 to earth
0
0
--
--
Unit shut down immediately.
0
--
--
Unit shut down immediately.
Single fault: D1 pin1 to 2 shorted
CN2 pin1 to pin2
Rev. 0
0
ATTACHMENT
Measurement Section
Page 56 of 73
Clause
Requirement + Test
Report No.:
Result - Remark
11021109 001
Verdict
CN2 pin1 to earth
0
0
--
--
Unit shut down immediately.
CN2 pin2 to earth
0
0
--
--
Unit shut down immediately.
T1 pin4 to pin5
0
0
--
--
Unit shut down immediately.
T1 pin5 to earth
0
0
--
--
Unit shut down immediately.
Single fault: U1 pin4 to 2 shorted
CN2 pin1 to pin2
0
0
--
--
Unit shut down immediately.
CN2 pin1 to earth
0
0
--
--
Unit shut down immediately.
CN2 pin2 to earth
0
0
--
--
Unit shut down immediately.
T1 pin4 to pin5
0
0
--
--
Unit shut down immediately.
T1 pin5 to earth
0
0
--
--
Unit shut down immediately.
Single fault: U3 pin19 to 20 shorted
CN2 pin1 to pin2
0
0
--
--
Unit shut down immediately.
CN2 pin1 to earth
0
0
--
--
Unit shut down immediately.
CN2 pin2 to earth
0
0
--
--
Unit shut down immediately.
T1 pin4 to pin5
0
0
--
--
Unit shut down immediately.
T1 pin5 to earth
0
0
--
--
Unit shut down immediately.
CN2 pin1 to pin2
0
0
--
--
Unit shut down immediately.
CN2 pin1 to earth
0
0
--
--
Unit shut down immediately.
CN2 pin2 to earth
3.7
1.65
59
41.3
T1 pin4 to pin5
0
0
--
--
Unit shut down immediately.
T1 pin5 to earth
0
0
--
--
Unit shut down immediately.
CN2 pin1 to pin2
0
0
--
--
Unit shut down immediately.
CN2 pin1 to earth
0
0
--
--
Unit shut down immediately.
CN2 pin2 to earth
0
0
--
--
Unit shut down immediately.
T1 pin4 to pin5
0
0
--
--
Unit shut down immediately.
T1 pin5 to earth
0
0
--
--
Unit shut down immediately.
Single fault: R14 shorted
Single fault: R20 shorted
Supplementary information:
Output measured with a 2kohm non-inductive resistor as load.
2.5
TABLE: limited power source measurement
Limits
Rev. 0
P
Measured
Verdict
ATTACHMENT
Measurement Section
Page 57 of 73
Clause
Requirement + Test
Report No.:
Result - Remark
11021109 001
Verdict
For USB Port (J_USB1 pin 1 to GND):
According to Table 2B - Normal condition, Uoc = 5.04Vdc
current (in A)
apparent power (in VA)
8
1.7
P
100
2.8
P
According to Table 2B - Single fault (U7 pin 2,3 to 6,7,8 short-circuited), Uoc = 5.04Vdc
current (in A)
apparent power (in VA)
8
7.0
P
100
19.8
P
8
1.7
P
100
2.8
P
For USB Port (J_USB2 pin 1 to GND):
According to Table 2B - Normal condition, Uoc = 5.04Vdc
current (in A)
apparent power (in VA)
According to Table 2B - Single fault (U7 pin 2,3 to 6,7,8 short-circuited), Uoc = 5.05Vdc
current (in A)
apparent power (in VA)
8
7.0
P
100
19.8
P
8
1.65
P
100
2.6
P
For USB Port (AJ-USB1 pin 1 to GND):
According to Table 2B - Normal condition, Uoc = 5.04Vdc
current (in A)
apparent power (in VA)
According to Table 2B - Single fault (U22 pin 2,3 to 6,7,8 short-circuited), Uoc = 5.04Vdc
current (in A)
apparent power (in VA)
8
2.9
P
100
4.7
P
8
3
P
100
5.7
P
For HDMI port (J_HDMI1 pin 18 to GND):
According to Table 2B - Normal condition, Uoc = 5.03Vdc
current (in A)
apparent power (in VA)
According to Table 2B - Single fault (Q29 pin 1,2,3 to 5,6,7,8 short-circuited), Uoc = 5.03Vdc
current (in A)
apparent power (in VA)
8
4.8
P
100
9.3
P
Supplementary information:
2.6.3.4
Location
Rev. 0
TABLE: Resistance of earthing measurement
Resistance measured (mΩ) Comments
N/A
ATTACHMENT
Measurement Section
Page 58 of 73
Clause
Report No.:
Requirement + Test
Result - Remark
11021109 001
Verdict
Supplementary information:
2.10.2
Table: Working voltage measurement
Location
RMS voltage (V)
N/A
Peak voltage (V) Comments
Supplementary information:
4.6.1, 4.6.2 Table: enclosure openings
Location
P
Size (mm)
Top / Right / Rear
--
Left
Max. 11 x 2.9
Bottom
Front (located at LCD panel)
Comments
None.
Numerous rectangle openings and covered
by fin type heat sink with 1.0 mm in width.
Max. 5.8 x 54.8
Express card slot use and covered by a metal
case and PCB completely.
Max. 4.0 x 24.6
9 in 1 card reader slot use and covered by a
metal case and PCB completely.
Max. 0.9 x 15.4
Max. 0.9 x 8.8
Max. 0.9 x 6.5
Numerous rectangle openings provided.
Max. Ø 0.6
Numerous circle openings provided under two
speakers.
Supplementary information:
5.1.6
TABLE: Touch current and protective conductor current measurement
Condition
L→ terminal A N → terminal A
(mA)
(mA)
Limit
(mA)
P
Comments
Measured with adapter by mfr. Darfon, type V173 and modem card by mfr. Motorola, type ML3054
From L/N to Tip
0.06
0.06
0.25
From L/N to Ring
0.06
0.06
0.25
Measured with adapter by mfr. Lite-On, type PA-1650-68 and modem card by mfr. Motorola, type
ML3054
From L/N to Tip
0.03
0.03
0.25
From L/N to Ring
0.03
0.03
0.25
Measured with adapter by mfr. Lite-On, type PA-1650-65 and modem card by mfr. Motorola, type
ML3054
Rev. 0
ATTACHMENT
Measurement Section
Page 59 of 73
Clause
Requirement + Test
Report No.:
Result - Remark
From L/N to Tip
0.03
0.03
0.25
From L/N to Ring
0.03
0.03
0.25
11021109 001
Verdict
Measured with adapter by mfr. FSP, type FSP065-RAB and modem card by mfr. Motorola, type
ML3054
From L/N to Tip
0.03
0.03
0.25
From L/N to Ring
0.03
0.03
0.25
Measured with adapter by mfr. Hipro, type HP-OK065B13 and modem card by mfr. Motorola, type
ML3054
From L/N to Tip
0.04
0.04
0.25
From L/N to Ring
0.04
0.04
0.25
Measured with adapter by mfr. Darfon, type V173 and modem card by mfr. Agere, type D40 (D40
AM5)
From L/N to Tip
0.04
0.04
0.25
From L/N to Ring
0.04
0.04
0.25
Measured with adapter by mfr. Lite-On, type PA-1650-68 and modem card by mfr. Agere, type D40
(D40 AM5)ML3054
From L/N to Tip
0.02
0.02
0.25
From L/N to Ring
0.02
0.02
0.25
Measured with adapter by mfr. Lite-On, type PA-1650-65 and modem card by mfr. Agere, type D40
(D40 AM5)
From L/N to Tip
0.02
0.02
0.25
From L/N to Ring
0.02
0.02
0.25
Measured with adapter by mfr. FSP, type FSP065-RAB and modem card by mfr. mfr. Agere, type D40
(D40 AM5)
From L/N to Tip
0.02
0.02
0.25
From L/N to Ring
0.02
0.02
0.25
Measured with adapter by mfr. Hipro, type HP-OK065B13 and modem card by mfr. Agere, type D40
(D40 AM5)
From L/N to Tip
0.03
0.03
0.25
From L/N to Ring
0.03
0.03
0.25
Supplementary information:
Input voltage : 264V for power adaptor
Input frequency : 60Hz for power adaptor
Overall capacity : In approved power adaptor
C.2
Rev. 0
TABLE: Insulation of transformers
ATTACHMENT
Measurement Section
Page 60 of 73
Clause
Requirement + Test
11021109 001
Result - Remark
Verdict
Transformer part name ........................... :

Manufacturer........................................... :

Type ........................................................ :

Clearance (cl) and creepage
distance (cr) at/of/between:
U peak
(V)
U r.m.s.
(V)
Primary /input winding and
secondary/output winding
(internal)
Primary/input winding and core
(internal)
Secondary/output winding and
core (internal)
Primary/input part and
secondary/output part
(external)
Primary/input part and core
(external)
Primary/input part and
secondary/output winding
(external)
Secondary/output part and
core (external)
Secondary/output part and
primary/input winding
(external)
Description of design:
(a) Bobbin
Primary/input pins
:
Secondary/output pins ............................................. :
Material (manufacturer, type, ratings) ...................... :
Thickness (mm)........................................................ :
(b) General
Supplementary information:
Rev. 0
Report No.:
Required
cl (mm)
cl
(mm)
Required
cr (mm)
cr
(mm)
ATTACHMENT
National Differences
Page 61 of 73
Report No.:
11021109 001
National Differences
Clause
Result – Remark
Requirement − Test
Verdict
EUROPEAN GROUP DIFFERENCES AND NATIONAL DIFFERENCES
Differences according to................:
EN 60950-1:2006+A11:2009
CENELEC COMMON MODIFICATIONS (EN)
ZA
Normative references to international publications with their corresponding
European publications

ZB
ANNEX ZB, SPECIAL NATIONAL CONDITIONS (EN)
P
1.2.13.14
In Norway and Sweden, for requirements see
1.7.2.1 and 7.3 of this annex.
Replace the existing SNC by the following:
Replaced.
In Finland, Norway and Sweden, resistors
bridging BASIC INSULATION in CLASS I PLUGGABLE
EQUIPMENT TYPE A must comply with the
requirements in 1.5.7.1. In addition when a single
resistor is used, the resistor must withstand the
resistor test in 1.5.7.2.
Add as new SNC:
Added.
In Norway and Sweden, the screen of the cable
distribution system is normally not earthed at
the entrance of the building and there is normally
no equipotential bonding system within the
building. Therefore the protective earthing of the
building installation need to be isolated from
the screen of a cable distribution system.
It is however accepted to provide the insulation
external to the equipment by an adapter or an
interconnection cable with galvanic isolator, which
may be provided by e.g. a retailer.
The user manual shall then have the following or
similar information in Norwegian and
Swedish language respectively, depending on in
what country the equipment is intended to be
used in:
“Equipment connected to the protective earthing
of the building installation through the
mains connection or through other equipment
with a connection to protective earthing –
and to a cable distribution system using coaxial
cable, may in some circumstances
create a fire hazard. Connection to a cable
distribution system has therefore to be
provided through a device providing electrical
isolation below a certain frequency range
(galvanic isolator, see EN 60728-11).”
1.5.7.1
1.7.2.1
N/A
N/A
N/A
NOTE In Norway, due to regulation for installations of cable
distribution systems, and in Sweden, a galvanic isolator
shall provide electrical insulation below 5 MHz. The insulation
shall withstand a dielectric strength of 1,5 kV r.m.s.,
50 Hz or 60 Hz, for 1 min.
Translation to Norwegian (the Swedish text will
IECEE CB Bulletin on 2009-04-16
European Group Differences and National Differences
ATTACHMENT
National Differences
Page 62 of 73
Report No.:
11021109 001
National Differences
Clause
1.7.5
7.3
Result – Remark
Requirement − Test
also be accepted in Norway):
“Utstyr som er koplet til beskyttelsesjord via
nettplugg og/eller via annet jordtilkoplet
utstyr – og er tilkoplet et kabel-TV nett, kan
forårsake brannfare. For å unngå dette skal
det ved tilkopling av utstyret til kabel-TV nettet
installeres en galvanisk isolator mellom
utstyret og kabel- TV nettet.”
Translation to Swedish:
”Utrustning som är kopplad till skyddsjord via
jordat vägguttag och/eller via annan
utrustning och samtidigt är kopplad till kabel-TV
nät kan i vissa fall medfőra risk főr
brand. Főr att undvika detta skall vid anslutning
av utrustningen till kabel-TV nät
galvanisk isolator finnas mellan utrustningen och
kabel-TV nätet.”
Add the following paragraph to the existing SNC
for Denmark:
For CLASS II EQUIPMENT the socket outlet shall be
in accordance with Standard Sheet
DKA 1-4a.
Delete the existing SNC for Norway and Sweden
(based on NOTE 1 of IEC 60950-1:2005 +
corr. 1).
Add as new SNC (based on future NOTE 3 of
IEC 60950-1:200X):
In Norway and Sweden, for requirements see
1.2.13.14 and 1.7.2.1 of this annex.
ZC
ANNEX ZC, NATIONAL DEVIATIONS (EN)
1.5.1
Sweden
Delete the A-deviation.
Denmark
Delete the A-deviation.
Denmark
Delete the A-deviation.
Denmark
Delete the A-deviation.
1.7.2.1
1.7.5
5.1.7.1
IECEE CB Bulletin on 2009-04-16
Verdict
Added.
N/A
Deleted.
N/A
N/A
Deleted.
N/A
Deleted.
N/A
Deleted.
N/A
Deleted.
N/A
European Group Differences and National Differences
ATTACHMENT
National Differences
Page 63 of 73
Report No.:
11021109 001
National Differences
Clause
Result – Remark
Requirement − Test
Canadian National Differences
Verdict
P
SPECIAL NATIONAL CONDITIONS
1.1.1
1.4.14
1.5.5
1.7.1
1.7.7
2.5
All equipment is to be designed to allow
installation in accordance with the National
Electrical Code (NEC), ANSI/NFPA 70, the
Canadian Electrical Code (CEC), Part I,
CAN/CSA C22.1, and when applicable, the
National Electrical Safety Code, IEEE C2. Also,
unless marked or otherwise identified, installation
is allowed per the Standard for the Protection of
Electronic Computer/Data-Processing Equipment,
ANSI/NFPA 75.
For Pluggable Equipment Type A, the protection
in the installation is assumed to be 20A.
For lengths exceeding 3.05 m, external
interconnecting flexible cord and cable
assemblies are required to be a suitable cable
type (e.g., DP, CL2) specified in the CEC/NEC.
For lengths 3.05 m or less, external
interconnecting flexible cord and cable
assemblies that are not types specified in the
CEC are required to have special construction
features and identification markings.
Equipment for use on a.c. mains supply systems
with a neutral and more than one phase
conductor (e.g. 120/240 V, 3-wire) require a
special marking format for electrical ratings.
A voltage rating that exceeds an attachment plug
cap rating is only permitted if it does not exceed
the extreme operating conditions in Table 2 of
CAN/CSA C22.2 No. 235, and if it is part of a
range that extends into the Table 2 "Normal
Operating Conditions." Likewise, a voltage rating
shall not be lower than the specified "Normal
Operating Conditions," unless it is part of a range
that extends into the "Normal Operating
Conditions."
Wiring terminals intended to supply Class 2
outputs in accordance with CEC Part 1 or NEC
shall be marked with the voltage rating and
“Class 2” or equivalent. Marking shall be located
adjacent to the terminals and shall be visible
during wiring.
Where a fuse is used to provide Class 2, Limited
Power Source, or TNV current limiting, it shall not
be operator-accessible unless it is not
interchangeable.
IECEE CB Bulletin on 2008-07-31
EUT in compliance with
requirements of IEC 60950-1.
Overall acceptance shall be
evaluated during national
approval.
N/A
Class III equipment.
N/A
N/A
Class III equipment.
N/A
N/A
No such fuse.
N/A
Canadian National Differences
ATTACHMENT
National Differences
Page 64 of 73
Report No.:
11021109 001
National Differences
Clause
Requirement − Test
2.7.1
Suitable NEC/CEC branch circuit protection rated No such components provided.
at the maximum circuit rating is required for all
standard supply outlets and receptacles (such as
supplied in power distribution units) if the supply
branch circuit protection is not suitable.
Power distribution transformers distributing power
at 100 volts or more, and rated 10 kVA or more,
require special transformer overcurrent
protection.
Wiring methods (terminals, leads, etc.) used for
the connection of the equipment to the mains
shall be in accordance with the NEC/CEC.
Power supply cords are required to have
attachment plugs rated not less than 125 percent
of the rated current of the equipment.
Equipment connected to a centralized d.c. power
system, and having one pole of the DC mains
input terminal connected to the main protective
earthing terminal in the equipment, is required to
comply with special earthing, wiring, marking and
installation instruction requirements.
Permanent connection of equipment to the mains
supply by a power supply cord is not permitted,
except for certain equipment, such as ATMs.
Power supply cords are required to be no longer
than 4.5 m in length.
Flexible power supply cords are required to be
compatible with Tables 11 and 12 of the CEC and
Article 400 of the NEC.
Permanently connected equipment is required to
have a suitable wiring compartment and wire
bending space.
Wiring terminals and associated spacings for field
wiring connections shall comply with CSA C22.2
No. 0.
Wire binding screws are not permitted to attach
2
conductors larger than 10 AWG (5.3 mm ).
Terminals for permanent wiring, including
protective earthing terminals, are required to be
suitable for Canadian/US wire gauge sizes, rated
125 percent of the equipment rating, and be
specially marked when specified (1.7.7).
Motor control devices are required for
cord-connected equipment with a motor if the
equipment is rated more than 12 A, or if the motor
has a nominal voltage rating greater than 120 V,
or is rated more than 1/3 hp (locked rotor current
over 43 A).
Vertically-mounted disconnect switches and
circuit breakers are required to have the "on"
position indicated by the handle in the up
position.
3.2
3.2.1
3.2.1.2
3.2.3
3.2.5
3.2.9
3.3
3.3.3
3.3.4
3.4.2
3.4.8
IECEE CB Bulletin on 2008-07-31
Result – Remark
Verdict
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Canadian National Differences
ATTACHMENT
National Differences
Page 65 of 73
Report No.:
11021109 001
National Differences
Clause
Requirement − Test
3.4.11
For computer room applications, equipment with
battery systems capable of supplying 750 VA for
five minutes are required to have a battery
disconnect means that may be connected to the
computer room remote power-off circuit.
The maximum quantity of flammable liquid stored
in equipment is required to comply with NFPA 30.
Equipment with lasers is required to meet the
Canadian Radiation Emitting Devices Act, REDR
C1370 and/or Code of Federal Regulations 21
CFR 1040, as applicable.
4.3.12
4.3.13.5
4.7
4.7.3.1
Annex H
Result – Remark
Verdict
N/A
N/A
Optical radiation in compliance
with requirements of IEC
60825-1 (see corresponding
sections of this test report).
Laser Comply with FDA
For computer room applications, automated
information storage systems with combustible
3
media greater than 0.76 m (27 cu ft) are required
to have a provision for connection of either
automatic sprinklers or a gaseous agent
extinguishing system with an extended discharge.
For computer room applications, enclosures with
combustible material measuring greater than 0.9
2
m (10 sq ft) or a single dimension greater than
1.8 m (6 ft) are required to have a flame spread
rating of 50 or less. For other applications,
enclosures with the same dimensions require a
flame spread rating of 200 or less.
Equipment that produces ionizing radiation is
No ionizing radiation.
required to comply with the Canadian Radiation
Emitting Devices Act, REDR C1370 and/or Code
of Federal Regulations, 21 CFR 1020, as
applicable.
P
N/A
N/A
N/A
OTHER DIFFERENCES
11.5.1
Some components and materials associated with Components are UL approved,
the risk of fire, electric shock, or personal injury
see appended table 1.5.1.
are required to have component or material
ratings in accordance with the applicable national
(Canadian and/or U.S.) component or material
standard requirements. These components
include:
attachment plugs, battery packs (rechargeable
type, used with transportable equipment),
cathode ray tubes, circuit breakers,
communication circuit accessories, connectors
(used for current interruption of non-LPS circuits),
cord sets and power supply cords, direct plug-in
equipment, enclosures (outdoor), flexible cords
and cables, fuses (branch circuit), fuseholders,
ground-fault current interrupters, industrial control
equipment, insulating tape, interconnecting
cables, lampholders, limit controls, printed wiring,
protectors for communications circuits,
receptacles, solid state controls, supplementary
IECEE CB Bulletin on 2008-07-31
P
Canadian National Differences
ATTACHMENT
National Differences
Page 66 of 73
Report No.:
11021109 001
National Differences
Clause
1.6.1.2
2.3.1
2.3.2.1
2.6.3.4
4.2.8.1
4.2.11
4.3.2
Requirement − Test
protectors, switches (including interlock
switches), thermal cutoffs, thermostats, (multilayer) transformer winding wire, transient voltage
surge suppressors, tubing, wire connectors, and
wire and cables.
A circuit for connection to the DC Mains Supply is
classified as either a SELV Circuit, TNV-2 Circuit
or Hazardous Voltage Circuit depending on the
maximum operating voltage of the supply. This
maximum operating voltage shall include
consideration of the battery charging “float
voltage” associated with the intended supply
system, regardless of the marked power rating of
the equipment.
For TNV-2 and TNV-3 circuits with other than
ringing signals and with voltages exceeding 42.4
Vpeak or 60 Vd.c., the maximum acceptable
current through a 2000 ohm resistor (or greater)
connected across the voltage source with other
loads disconnected is 7.1 mA peak or 30 mA d.c.
under normal operating conditions.
In the event of a single fault between TNV and
SELV circuits, the limits of 2.2.3 apply to SELV
Circuits and accessible conductive parts.
Protective bonding conductors of non-standard
protective bonding constructions (e.g., printed
circuit traces) may be subjected to the additional
limited short circuit test conditions specified.
Enclosures around CRTs with a face diameter of
160 mm or more are required to reduce the risk of
injury due to the implosion of the CRT.
For equipment intended for mounting on racks
and provided with slide/rails allowing the
equipment to slide away from the rack for
installation, service and maintenance, additional
construction, performance and marking
requirements are applicable to determine the
adequacy of the slide/rails.
Equipment with handles is required to comply
with special loading tests.
IECEE CB Bulletin on 2008-07-31
Result – Remark
Verdict
N/A
TNV-3 circuits without other
than ring signals.
Complied.
N/A
P
N/A
No CRT.
N/A
N/A
N/A
Canadian National Differences
ATTACHMENT
National Differences
Page 67 of 73
Report No.:
11021109 001
National Differences
Clause
Requirement − Test
Result – Remark
5.1.8.3
Equipment intended to receive
Considered.
telecommunication ringing signals is required to
comply with a special touch current measurement For Motorola / ML3054:
1). To SELV=0.01mA
tests.
2). To plastic enclosure with
foil=0.01mA
Verdict
P
3). To Keyboard=0.01mA
For Agere / D40 (D40 AM5):
1). To SELV=0.1mA
2). To plastic enclosure with
foil=0.01mA
3). To Keyboard=0.01mA
5.3.7
6.4
M.2
Annex
NAD
Annex
NAF
Internal (e.g., card cage) SELV circuit connectors
and printed wiring board connectors that are
accessible to the operator and that deliver power
are to be overloaded.
During abnormal operating testing, if a circuit is
interrupted by the opening of a component, the
test shall be repeated twice (three tests total)
using new components as necessary.
Equipment intended for connection to
telecommunication network outside plant cable is
required to be protected against overvoltage from
power line crosses in accordance with 6.4 and
Annex NAC.
Continuous ringing signals up to 16 mA only are
permitted if the equipment is subjected to special
installation and performance restrictions.
Equipment connected to a telecommunication
and cable distribution networks and supplied with
an earphone intended to be held against, or in the
ear is required to comply with special acoustic
pressure requirements.
Document (paper) shredders likely to be used in
a home or home office (Pluggable Equipment
Type A plug configuration) are required to comply
with additional requirements, including
markings/instructions, protection against
inadvertent reactivation of a safety interlock,
disconnection from the mains supply (via
provision of an isolating switch), and protection
against operator access (accessibility determined
via new accessibility probe & probe/wedge).
IECEE CB Bulletin on 2008-07-31
N/A
Considered.
Minimum No.26 AWG
telecommunication line cord
used and overvoltage test were
performed on modem module
(Tip-Ring) and on unit itself
under different test conditions
according to sub-clause 6.4
and Annex NAC.
P
N/A
N/A
N/A
Canadian National Differences
ATTACHMENT
National Differences
Page 68 of 73
Report No.:
11021109 001
National Differences
Clause
Requirement − Test
Result – Remark
Korean National Differences
Verdict
P
Corresponding National Standard: K 60950-1
1.5.101
Addition:
Plugs for the connection of the apparatus to the
supply mains shall comply with the Korean
requirement (KSC 8305).
No plug provided.
N/A
8
Addition: EMC
The apparatus shall comply with the relevant
CISPR standards.
To be evaluated when
submitted for national approval.
N/A
IECEE CB Bulletin on 2007-05-29
Korean National Differences
ATTACHMENT
National Differences
Page 69 of 73
Report No.:
11021109 001
National Differences
Clause
Requirement − Test
Result – Remark
Verdict
US National Differences
P
SPECIAL NATIONAL CONDITIONS BASED ON FEDERAL REGULATIONS
1.1.1
1.4.14
1.5.5
1.7.1
2.5
2.7.1
3.2
3.2.1
3.2.1.2
3.2.3
All equipment is to be designed to allow
installation in accordance with the National
Electrical Code (NEC), ANSI/NFPA 70, and when
applicable, the National Electrical Safety Code,
IEEE C2. Also, unless marked or otherwise
identified, installation is allowed per the Standard
for the Protection of Electronic Computer/DataProcessing Equipment, ANSI/NFPA 75.
For Pluggable Equipment Type A, the protection
in the installation is assumed to be 20A.
For lengths exceeding 3.05 m, external
interconnecting flexible cord and cable
assemblies are required to be a suitable cable
type specified in the NEC. For lengths 3.05 m or
less, external interconnecting flexible cord and
cable assemblies that are not types specified in
the NEC are required to have special construction
features and identification markings.
Equipment for use on a.c. mains supply systems
with a neutral and more than one phase
conductor (e.g. 120/240 V, 3-wire) require a
special marking format for electrical ratings.
Where a fuse is used to provide Class 2, Limited
Power Source, or TNV current limiting, it shall not
be operator-accessible unless it is not
interchangeable.
Suitable NEC branch circuit protection rated at
the maximum circuit rating is required for all
standard supply outlets and receptacles (such as
supplied in power distribution units) if the supply
branch circuit protection is not suitable. Power
distribution transformers distributing power at 100
volts or more, and rated 10 kVA or more, require
special transformer overcurrent protection.
Wiring methods (terminals, leads, etc.) used for
the connection of the equipment to the mains
shall be in accordance with the NEC.
Power supply cords are required to have
attachment plugs rated not less than 125 percent
of the rated current of the equipment.
Equipment connected to a centralized d.c. power
system, and having one pole of the DC mains
input terminal connected to the main protective
earthing terminal in the equipment, is required to
comply with special earthing, wiring, marking and
installation instruction requirements.
Permanent connection of equipment to the mains
supply by a power supply cord is not permitted,
except for certain equipment, such as ATMs.
IECEE CB Bulletin on 2007-08-08
EUT in compliance with
requirements of IEC 60950-1.
Overall acceptance shall be
evaluated during national
approval.
N/A
See above.
N/A
N/A
N/A
N/A
N/A
Class III equipment.
N/A
N/A
N/A
N/A
US National Differences
ATTACHMENT
National Differences
Page 70 of 73
Report No.:
11021109 001
National Differences
Clause
Requirement − Test
3.2.5
Power supply cords are required to be no longer
than 4.5 m in length and minimum length shall be
1.5 m. Flexible power supply cords are required
to be compatible with Article 400 of the NEC.
Permanently connected equipment must have a
suitable wiring compartment and wire bending
space.
Wire binding screws are not permitted to attach
conductors larger than 10 AWG (5.3 mm2).
Terminals for permanent wiring, including
protective earthing terminals, must be suitable for
U.S wire gauge sizes, rated 125 percent of the
equipment rating, and be specially marked when
specified (1.7.7).
Motor control devices are required for cordconnected equipment with a motor if the
equipment is rated more than 12 A, or if the motor
has a nominal voltage rating greater than 120 V,
or is rated more than 1/3 hp (locked rotor current
over 43 A).
Vertically-mounted disconnect switches and
circuit breakers are required to have the "on"
position indicated by the handle in the up
position.
For computer room applications, equipment with No mains connection.
battery systems capable of supplying 750 VA for
five minutes are required to have a battery
disconnect means that may be connected to the
computer room remote power-off circuit.
The maximum quantity of flammable liquid stored
in equipment is required to comply with NFPA 30.
Equipment with lasers is required to meet the
Optical radiation in compliance
Code of Federal Regulations 21 CFR 1040.
with requirements of IEC
60825-1 (see corresponding
sections of this test report).
Laser Comply with FDA
N/A
For computer room applications, automated
information storage systems with combustible
media greater than 0.76 m3 (27 cu ft) are
required to have a provision for connection of
either automatic sprinklers or a gaseous agent
extinguishing system with an extended discharge.
For computer room applications, enclosures with
combustible material measuring greater than 0.9
m2 (10 sq ft) or a single dimension greater than
1.8 m (6 ft) are required to have a flame spread
rating of 50 or less. For other applications,
enclosures with the same dimensions require a
flame spread rating of 200 or less.
Equipment that produces ionizing radiation must No ionizing radiation.
comply with Federal Regulations, 21 CFR 1020
N/A
3.2.9
3.3.3
3.3.4
3.4.2
3.4.8
3.4.11
4.3.12
4.3.13.5
4.7
4.7.3.1
Annex H
IECEE CB Bulletin on 2007-08-08
Result – Remark
Verdict
N/A
N/A
N/A
N/A
N/A
N/A
N/A
P
N/A
N/A
US National Differences
ATTACHMENT
National Differences
Page 71 of 73
Report No.:
11021109 001
National Differences
Clause
Requirement − Test
Result – Remark
1.5.1
Some components and materials associated with
the risk of fire, electric shock, or personal injury
are required to have component or material
ratings in accordance with the applicable national
(U.S. and Canadian) component or material
requirements. These components include:
attachment plugs, battery packs (rechargeable
type, used with transportable equipment),
cathode ray tubes, circuit breakers,
communication circuit accessories, connectors
(used for current interruption of non-LPS circuits),
cord sets and power supply cords, direct plug-in
equipment, enclosures (outdoor), flexible cords
and cables, fuses (branch circuit), fuseholders,
ground-fault current interrupters, industrial control
equipment, insulating tape, interconnecting
cables, lampholders, limit controls, printed wiring,
protectors for communications circuits,
receptacles, solid state controls, supplementary
protectors, switches (including interlock
switches), thermal cutoffs, thermostats, (multilayer) transformer winding wire, transient voltage
surge suppressors, tubing, wire connectors, and
wire and cables.
A circuit for connection to the DC Mains Supply is
classified as either a SELV Circuit, TNV-2 Circuit
or Hazardous Voltage Circuit depending on the
maximum operating voltage of the supply. This
maximum operating voltage it to include
consideration of the battery charging “float
voltage” associated with the intended supply
system, regardless of the marked power rating of
the equipment.
For TNV-2 and TNV-3 circuits with other than
ringing signals and with voltages exceeding 42.4
Vpeak or 60 Vd.c., the max. acceptable current
through a 2000 ohm resistor (or greater)
connected across the voltage source with other
loads disconnected is 7.1 mA peak or 30 mA d.c.
under normal operating conditions.
In the event of a single fault between TNV and
SELV circuits, the limits of 2.2.3 apply to SELV
Circuits and accessible conductive parts.
Protective bonding conductors of non-standard
protective bonding constructions (e.g., printed
circuit traces) may be subjected to the additional
limited short circuit test conditions specified.
Enclosures around CRTs with a face diameter of
160 mm or more are required to reduce the risk of
injury due to the implosion of the CRT.
Verdict
OTHER NATIONAL DIFFERENCES
1.6.1.2
2.3.1
2.3.2.1
2.6.3.4
4.2.8.1
IECEE CB Bulletin on 2007-08-08
Components are UL approved,
see component list 1.5.1.
P
N/A
TNV-3 circuits without other
than ring signals.
Complied.
N/A
P
N/A
N/A
US National Differences
ATTACHMENT
National Differences
Page 72 of 73
Report No.:
11021109 001
National Differences
Clause
Requirement − Test
4.2.11
For equipment intended for mounting on racks
and provided with slide/rails allowing the
equipment to slide away from the rack for
installation, service and maintenance, additional
construction, performance and marking
requirements are applicable to determine the
adequacy of the slide/rails.
Equipment with handles is required to comply
with special loading tests.
Equipment intended to receive
Considered.
telecommunication ringing signals is required to
comply with a special touch current measurement For Motorola / ML3054:
4). To SELV=0.01mA
tests.
5). To plastic enclosure with
foil=0.01mA
4.3.2
5.1.8.3
Result – Remark
Verdict
N/A
N/A
P
6). To Keyboard=0.01mA
For Agere / D40 (D40 AM5):
4). To SELV=0.1mA
5). To plastic enclosure with
foil=0.01mA
6). To Keyboard=0.01mA
5.3.7
6.4
M.2
Annex
NAD
Internal (e.g., card cage) SELV circuit connectors
and printed wiring board connectors that are
accessible to the operator and that deliver power
are to be overloaded. During abnormal operating
testing, if a circuit is interrupted by the opening of
a component, the test shall be repeated twice
(three tests total) using new components as
necessary.
Equipment intended for connection to
telecommunication network outside plant cable is
required to be protected against overvoltage from
power line crosses in accordance with 6.4 and
Annex NAC.
Continuous ringing signals up to 16 mA only are
permitted if the equipment is subjected to special
installation and performance restrictions.
Equipment connected to a telecommunication
and cable distribution networks and supplied with
an earphone intended to be held against, or in the
ear is required to comply with special acoustic
pressure requirements.
IECEE CB Bulletin on 2007-08-08
N/A
Minimum No.26 AWG
telecommunication line cord
used and overvoltage test were
performed on modem module
(Tip-Ring) and on unit itself
under different test conditions
according to sub-clause 6.4
and Annex NAC.
P
N/A
N/A
US National Differences
ATTACHMENT
National Differences
Page 73 of 73
Report No.:
11021109 001
National Differences
Clause
Requirement − Test
Annex
NAF
Document (paper) shredders likely to be used in
a home or home office (Pluggable Equipment
Type A plug configuration) are required to comply
with additional requirements, including
markings/instructions, protection against
inadvertent reactivation of a safety interlock,
disconnection from the mains supply (via
provision of an isolating switch), and protection
against operator access (accessibility determined
via new accessibility probe & probe/wedge).
IECEE CB Bulletin on 2007-08-08
Result – Remark
Verdict
N/A
US National Differences
ATTACHMENT
Photo Documentation
Page 1 of 8
Product:
NOTEBOOK COMPUTER
Type Designation: T510X, T511X (X can be 0-9 or blank)
Rev. 0
Report No.:
11021109 001
ATTACHMENT
Photo Documentation
Page 2 of 8
Product:
NOTEBOOK COMPUTER
Type Designation: T510X, T511X (X can be 0-9 or blank)
Rev. 0
Report No.:
11021109 001
ATTACHMENT
Photo Documentation
Page 3 of 8
Product:
NOTEBOOK COMPUTER
Type Designation: T510X, T511X (X can be 0-9 or blank)
Rev. 0
Report No.:
11021109 001
ATTACHMENT
Photo Documentation
Page 4 of 8
Product:
NOTEBOOK COMPUTER
Type Designation: T510X, T511X (X can be 0-9 or blank)
Rev. 0
Report No.:
11021109 001
ATTACHMENT
Photo Documentation
Page 5 of 8
Product:
NOTEBOOK COMPUTER
Type Designation: T510X, T511X (X can be 0-9 or blank)
Rev. 0
Report No.:
11021109 001
ATTACHMENT
Photo Documentation
Page 6 of 8
Product:
NOTEBOOK COMPUTER
Type Designation: T510X, T511X (X can be 0-9 or blank)
Rev. 0
Report No.:
11021109 001
ATTACHMENT
Photo Documentation
Page 7 of 8
Product:
NOTEBOOK COMPUTER
Type Designation: T510X, T511X (X can be 0-9 or blank)
For DC/AC Inverter: MITAC, type M660JEINT-D
Rev. 0
Report No.:
11021109 001
ATTACHMENT
Photo Documentation
Page 8 of 8
Product:
NOTEBOOK COMPUTER
Type Designation: T510X, T511X (X can be 0-9 or blank)
For DC/AC Inverter: Taiwan Sumida, type M660SRUINT-E
Rev. 0
Report No.:
11021109 001
Was this manual useful for you? yes no
Thank you for your participation!