DATA SHEET
EcoFill ® Wx Blowing Insulation
DESCRIPTION
EcoFill Wx blowing insulation is an unbonded, fiberglass blowing insulation with a high degree of recycled content, designed for weatherizing and retrofitting existing housing or new construction.
APPLICATION
• Open blows in attics
• Dense-pack sidewalls using the drill-and fill-technique
SPECIFICATION COMPLIANCE
• ASTM C764; Type I
• HH-I-1030B; Class B Certified
• Meets the Quality Standards of the State of California
INDOOR AIR QUALITY
• UL Environment
• GREENGUARD Certified
• GREENGUARD Gold Certified
• Validated to be Formaldehyde-Free
• EUCEB Certified
FIBERGLASS AND MOLD
Fiberglass insulation will not sustain mold growth. However, mold can grow on almost any material when it becomes wet and contaminated. Carefully inspect any insulation that has been exposed to water. If it shows any sign of mold it must be discarded. If the material is wet but shows no evidence of mold, it should be dried rapidly and thoroughly. If it shows signs of facing degradation from wetting, it should be replaced.
CONTRACTOR: ______________________________________
JOB: _______________________________________________
DATE: ______________________________________________
DOING MORE FOR THE WORLD WE LIVE IN.
All of our products are made from sustainable resources, such as recycled glass and sand. And we’re proud to be putting glass bottles back to work rather than into landfills. Our products are made with a minimum of 50% recycled glass—totaling an average of 26 million bottles each month.
TECHNICAL DATA
Property (Unit)
Corrosion
Critical Radiant Flux
Combustibility
Water Vapor Sorption (by weight)
Mold Growth
Surface Burning Characteristics
(flame spread/smoke developed)
Test
ASTM C764
ASTM E970
ASTM E136
ASTM C1104
ASTM C1338
ASTM E84, CAN/ULC S102
Performance
Pass
Greater than 0.12 W/cm²
Non-combustible
5% maximum
Pass
25/50
THERMAL PERFORMANCE
The stated thermal resistance (R-value) is provided by installing the required number of bags per 1,000 square feet of net area, at not less than the labeled minimum thickness (per the manufacturer’s instructions). Failure to install both the required number of bags and at least the minimum thickness will result in lower insulation R-values.
Field blending of this product with other loose fill insulation or application of this product in conjunction with adhesive or binder systems may affect its thermal performance and is not recommended by the manufacturer.
EQUIPMENT REQUIRED
To achieve labeled R-value, this product must be applied with a pneumatic blowing machine and a corrugated hose with a minimum 0.25" internal corrugation, a minimum length of 150' and a diameter of at least 3". Coils in the hose should not be less than 36" in diameter. The recommended feed rate is 15–25 lbs./min. For closed cavity applications, fabric or netting must be applied.
OPEN ATTIC APPLICATION
R-Value*
To obtain an insulation resistance of:
R-11
Min. Bags/
1,000 Sq. Ft.
Number of bags per
1,000 square feet of net area should not be less than:
5.3
R-30
R-38
R-44
R-49
R-60
R-13
R-19
R-22
R-26
15.3
19.9
23.4
26.3
33.3
6.4
9.4
10.9
13.2
Max. Coverage/Bag
Contents of this bag should not cover more than:
188.4 sq. ft.
156.6 sq. ft.
106.6 sq. ft.
91.4 sq. ft.
75.9 sq. ft.
65.5 sq. ft.
50.2 sq. ft.
42.7 sq. ft.
38.0 sq. ft.
30.1 sq. ft.
Net Min. Weight/
Sq. Ft.
Weight per square foot of installed insulation should not be less than:
0.152 lbs.
0.183 lbs.
0.268 lbs.
0.313 lbs.
0.377 lbs.
0.437 lbs.
0.569 lbs.
0.670 lbs.
0.753 lbs.
0.952 lbs.
Initial Installed
Thickness
Installed insulation should not be less than:
9 1 ⁄
8
"
10 3 ⁄
8
"
13"
14 7 ⁄
8
"
16 3 ⁄
8
"
193/4"
4"
43/4"
63/4"
73/4"
Min. Settled
Thickness**
Installed insulation should not be less than:
9 1 ⁄
8
"
10 3 ⁄
8
"
13"
14 7 ⁄
8
"
16 3 ⁄
8
"
193/4"
4"
43/4"
63/4"
73/4"
Bag Net Weight - Nominal 28.6 lbs., Minimum 31 lbs.
Coverage and installation data were determined using a Volu-Matic ® III blowing machine in third gear with 13" gate opening, 2.5–3.0 PSI air pressure, 150' of 3" diameter internally-corrugated hose. Volu-Matic III is a registered trademark of CertainTeed Corporation.
*“R” means resistance to heat flow. The higher the R-value, the greater the insulating power. To get the marked R-value, it is essential that this insulation be installed properly.
If you do it yourself, get instructions and follow them carefully. Instructions do not come with this package.
**Based on Third Party 10-year settling study, the predicted settlement over a 20-year period would be 1 percent or less. This amount of settling is thermally insignificant.
Therefore, the installed and settled thicknesses are effectively the same.
CAVITY WALL APPLICATION - DENSE PACK
R-Value*
Framing
Cavity
Depth To obtain a thermal resistance of:
2" x 4"
2" x 6"
2" x 8"
2" x 10"
3.50"
5.50"
7.25"
9.25"
R-15
R-23
R-31
R-39
Density
2.2 PCF
2.2 PCF
2.2 PCF
2.2 PCF
Bags/
1,000 Sq. Ft.
Number of bags per
1,000 square feet of net area should not be less than:
22.4
35.3
46.5
59.3
Max.
Coverage/Bag
Contents of this bag should not cover more than:
44.6 sq. ft.
28.4 sq. ft.
21.5 sq. ft.
16.9 sq. ft.
Net Min.
Weight/Sq. Ft.
Weight per square foot of installed insulation should not be less than:
0.624 lbs.
1.008 lbs.
1.329 lbs.
1.696 lbs.
AIR FLOW RESISTANCE VS. DENSITY
4,500,000
4,000,000
3,500,000
3,000,000
2,500,000
2,000,000
1,500,000
1,000,000
500,000
1.00
1.50
EcoFill Wx
2.00
2.2
2.50
Cellulose
3.00
DENSITY lb/ft 3
3.50
4.00
4.50
5.00
Ecofill Wx
Cellulose A
Cellulose B
Cellulose C
CERTIFICATIONS
Check with your Knauf Insulation Territory Manager to ensure information is current.
The chemical and physical properties of this product represent average values determined in accordance with accepted test methods. The data is subject to normal manufacturing variations. The data is supplied as a technical service and is subject to change without notice. References to numerical flame spread ratings are not intended to reflect hazards presented by these or any other materials under actual fire conditions.
This product is covered by one or more U.S. and/or other patents.
See patent www.knaufnorthamerica.com/patents
Visit knaufnorthamerica.com
to learn more.
KNAUF INSULATION, INC.
One Knauf Drive
Shelbyville, IN 46176
Technical Support
(317) 398-4434 ext. 8727 [email protected]
01-20
© 2020 Knauf Insulation, Inc.
![](http://s1.manualzz.com/store/data/067357546_1-e1ab8a0a8fe63c9bb183579ca9d93105-210x147.png)
Advertisement