Preface]
Thank you for choosing the wireless alarm system product of our company.
Wireless alarm system adopts the most advanced digital sensing and
controlling technologies, it is the intelligent alarm control system containing burglar
alarm, fire alarm, fire fighting, gas leakage and SOS.
Wireless alarm system uses the most advanced multiple random selection
technology, it avoids the problems of interference and alarm missing which usually
[Function Introduction]
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
exist in the similar systems. This system can be used widely in residence, shops,
villa, and small enterprise and so on.
For your safety, before installing and using, we suggest you read this manual
carefully.
Caution:To ensure that you can enjoy the impeccable warranty service, do not
open the host-housing to repair and renovation by yourself or we will not provide
11.
12.
13.
14.
15.
16.
17.
free warranty service. All the losses and the adverse consequences it makes will be
assumed by users.
Please make safekeeping to the user manual for reference when it is
necessary.
18.
19.
20.
21.
22.
23.
24.
25.
Touch screen keypad GSM alarm system
8 Wired defense zones and 100 wireless defense zones.
At most 5 wireless remote control codes.
Touch keypad, Built-in clock.,LCD display. Operate easily.
Voice prompt for each operation.
SMS prompt automatically about low power of battery.
SMS prompt when AC power lost or recovered.
Built-in intercom horn, two way communication can be realized.
Built-in wireless transmitting module, could be coding with wireless siren.
Build-in wireless transmitter,can control 4 relay outputs with home
appliances,such as lights,garage door,television,curtain,etc.
1 group timed Arm and timed Disarm function.
Can store 6 groups of phone numbers: when alarming, system will make
alarm call to these numbers automatically.
Can store 2 groups of SMS numbers: when alarming, system will send
alarming SMS to these numbers automatically.
Can store 2 alarm center telephones.
Inquire the status of alarm panel by SMS.
Delay alarming for each defense zone(0-99 seconds)
10-second voice message recording can be played automatically when
alarming.
The host can be used as a hand-free phone. Users can make call by the
keypad for telephone fee inquiry and charging.
One-key-control function: Out Arm, Home Arm, Remote Arm.
Real-time, delay, 24 hours, bypass defense zones programming function.
Wireless coding: easy to add additional wireless accessories.
Remote control Arm, Disarm, Monitor, and Intercom by phone.
Event Log Query: host automatically records 40 pieces of all information
concerning arm, disarm and alarm events.
Multi-type of arm: Remote control arm, out arm, home arm, timed arm, arm
by phone.
Built-in AAA NI-MH rechargeable battery: make alarm when power off.
[Alarm Host Diagram]
wire connecting terminal:
The host shall be installed in the Centre of the prevent site which could realize best
receiving effect from all wireless detectors. Please note that keep the host away
from large-sized metallic objects and home appliances producing high-frequency
interference; meanwhile avoid steel-reinforced concrete and fire-proof doors.
Panel schemes:
LCD display:
Installation drawing on the back:
[Function Setting]
4. Coding of Remote Controller Setting
The remote controller has to be coded to the alarm host in order to perform
1. Initialization
normally.
Please insert SIM card and insert the adapter output terminal into the power hole of
Press
the host, and then power on the system. Alarm panel will take about 1 min to search
input instruction code [21], Press
the GSM network.in the period of searching GSM network,the alarm panel will be in
control coding” .the [
] indicator is on without flashing; Press any button on
the wireless remote controller, the host makes a long beep and you will hear
Freeze status for a while ,until
work properly.
appear on LCD display,the alarm panel will
2. System setting
Press
firstly, then input 4- digit password by the keypad on the host. You will
hear a voice prompt: please enter instruction. You can perform different settings
repeatedly as long as the system keeps in setting status and after input different
firstly, then input 4- digit password by the keypad on the host,and
to confirm,then you will hear “remote
“coding completed” [
] indicators goes out, indicating the remote controller
succeeds in coding. The code of next remote controller will be displayed on the
LCD screen automatically
, when coding completed.
Operating method :
Password [21]
Notes: The same remote controller could be coded just one time. You can add
maximum 5 remote controllers.
LCD display:
settings,press
to confirm. The system will exit setting mode and return to main
interface if you don't press any keypad button for 40 seconds.
Note: The system default password is [6666].
Operating method:
Passwordsetting code
X indicates: 4-digits program password.
LCD display:
5. Remote Controller Deleting Setting
The remote controller can’t control the host after it is deleted.
Press
firstly, then input 4- digit password by the keypad,and input
instruction code [22], Press
to confirm.The main
hear a voice prompt “delete completed”.
Operating:
Password [22]
LCD display:
3. Exit Setting
Press
buttons, the host emits a long beep and exits settings to main-interface.
a long beep, You will
LCD display:
6. Coding of Wireless Detector Setting
Wireless detectors have to be coded to the host in order to trigger its
alarm.
Press
firstly, then input 4- digit password by the keypad,and input instruction
code [23], input the defense zone number you want to code [02~99],Press
to confirm,The host emits a long beep and the corresponding defense zone is
displayed on the screen. You will hear a voice prompt “detector coding”. Then
trigger a wireless detector to emit a wireless signal; after receiving the signal,
8. All Wireless Detector Deleting Setting
the host makes a long beep, and you will hear “ coding completed”, the
[
] indicator goes out at the same time.
Operating method:
The wireless detector can’t trigger the host to alarm after the whole
deletion.
Press
Password[23][XX]
XX Indicates:02~99 defense zones number
firstly, then input 4- digit password by the keypad,input instruction
code[25],and then press
to confirm.The host emits a long beep,and You will
hear a voice prompt “delete completed”.
Example:
Password[23][02]
LCD display:
Operating method:
LCD display:
7. Single Wireless Detector Deleting Setting
Password[25]
The wireless detector can’t control the host after it is deleted.
9.
Alarm Zone Type Setting
Press
firstly, then input 4- digit password by the keypad,input instruction
code [24] and then press the [02~99] defense zone number needs to be deleted,
Alarm Zone type is convenient to decide which detector will be alarmed.
finally press
to confirm. The host emits a long beep ,You will hear a voice
prompt “delete completed”.
1). Detector alarm type is set to “0”: This detector will not trigger the host to alarm
Operating method:
Password[24][XX]
XX indicates:02~99 defense zones number。
Example:Delete 02 defense zones
Operating method:
Password[24][02]
There are 4 defense types:
in any status.
2). Detector alarm type is set to “1”: This detector will trigger the host to alarm
whether in out arm or home arm.
3). Detector alarm type is set to “2”: This detector will trigger the host to alarm
only in Out Arm state; host is in Home Arm state, the detector cannot trigger the
host to alarm.
4). Detector alarm type is set to “3”: This detector will trigger the host to alarm in
Password[47][82][1]
Operating method:
LCD display:
any status.
Wireless detector alarm type setting
Press
firstly, then input 4- digit password by the keypad,input instruction code
[26], and press the defense zone [02~99] and then input [0~3] about detector
alarm type, finally press
to confirm. The host emits a long beep,You will hear a
voice prompt “setting completed”
Operating method:
Password[26][XX][Y]
XX indicates: two defense zones number.
Y indicates: one defense zone alarm type
Example: setting 02 defense zone alarm type to be Out Arm or Home Arm.
Operating method:
LCD display:
Password[26][02][1]
10.Wireless Equipment Coding Setting
Press
firstly, then input 4- digit password by the keypad,input instruction
code [27] + 8 wireless equipment coding, then enter to confirm. The host
makes a long beep,you will hear a voice prompt “setting completed”.
Note: Wireless equipment coding includes sc2262 coding four data bits & 8
address bits.
Operating method:
Password[27][XXXXXXXX]
XXXXXXXX indicates:8 wireless equipment coding
Example: detailed operating of wireless equipment coding is“01020102”
Operating method:
LCD display
Wired detector alarm type setting
Press
firstly, then input 4- digit password by the keypad,input instruction
code [47], and then press the defense zone [81~88] and then input [0~3] about
detector alarm type, finally press to confirm. The host emits a long beep ,You
will hear a voice prompt “setting completed”
Operating method:
Password[47][XX][Y]
XX indicates: two defense zones number.
Y indicates: one defense zone alarm type
Notes: wired defense zone of Z1 is equal to zone of 81, wired defense zone of
Password[27][01020102]
11.Remote Controller Sound Prompt setting
In arm or disarm, external siren prompt arm or disarm.
Press
firstly, then input 4- digit password by the keypad,input instruction
code [31] on the keypad, then enter[0~1], finally press
;The host makes a
long beep. You will hear a voice prompt “setting completed”.
Operating method:
Password[31][X]
X =“0” indicates:Remote controller Sound Prompt closed;
X =“1” indicates: Remote controller Sound Prompt open;
Z2 is equal to zone of 82, and wired defense zone of Z8 is equal to zone of 88
Example: Detailed operating of external siren prompt open
in turn.
Operating method:
LCD display:
Example: alarm type about defense zone of 82 is set to out arm or home arm.
Password[31][1]
Example: detailed operating of 2 seconds delayed time arm.
Operating method:
LCD display:
Password[33][02]
12.Siren Ring Time setting(Default:3 minutes)
Press
firstly, then input 4- digit password by the keypad,input instruction
code [32] on the keypad, then enter time [00~15] minutes, finally press
;
The host make a long beep, You will hear a voice prompt “setting completed”.
Operating method:
Password[32][XX]
XX indicates: siren ring time, unit “minute”.
Example: Set 5 minutes of siren ring time.
Operating method:
LCD display
Password[32][05]
14.Alarm Delayed Setting
Alarm time delayed setting is that the host will not alarm until delayed
time arrives.
Press
firstly, then input 4- digit password by the keypad,input instruction
[34], enter zone number [00~99], and then input delayed time [00~99] seconds,
finally press
to confirm. The host makes a long beep. You will hear a voice
prompt “setting completed”.
Operating method:
Password[34][XX][XX]
XX indicates:Alarm delayed time, unit: second
Example: Detailed operating of 5 seconds alarm delayed time to 04 zone.
Operating method:
LCD display:
Password[34][04][05]
13.Arm Time Delayed Setting(Default:30 seconds)
When press down the key of Out Arm, the host will arm according to the
delayed time after setting.
Press
firstly, then input 4- digit password by the keypad,input instruction [33],
then input [00~99], press
to confirm. The host makes a long beep. You will
hear a voice prompt “setting completed”.
Operating method:
Password[33][XX]
XX indicates:Arm delayed time, unit: second.
15. Telephone Dial-up Cycle Times Setting(Default:9
Times)
Alarm dial-up cycle times are the times of dial-up from the beginning
again, if all the phone numbers are dial-up, but no answer.
Press
firstly, then input 4- digit password by the keypad,input instruction
[35], then input dial-up cycle time [00~09] times, finally press
to confirm.
The host makes a long beep. You will hear a voice prompt “setting completed”.
Password[35][XX]
XX indicates: Telephone dial-up cycle times.
Operating method:
17. Voice Recording message Setting
Pres s
firstly, then input 4- digit password by the keypad,input
instruction [37],and then press
to confirm.
Example: Detailed operating about 2 cycle times.
The host will emits a beep and the [
] indicator is on, and after 10 second
s countdown, recording starts: record at 30cm away from the host with mod
Password[35][02]
erate tone;10 seconds later, the host will make a beep indicating the recording
Operating method:
LCD display:
finish and the recorded voice will replay.
Operating method:
LCD display:
Password[37]
16 Remote Call Ringing Times Setting(Default:6 Times)
Users dial-up the telephone connected to the host, then the signal of ringing times
Note: when you need to change the content of recording, just store your new one.
would transfer to the host. Users through voice prompt, input correct password to
get remote control setting to the host.
Press
firstly, then input 4- digit password by the keypad,input instruction
[36], then input delayed time [0~9] times, finally press
to confirm. Main unit
make a long beep. You will hear a voice prompt “setting completed”.
Operating method:
Password[36][X]
X indicates:ring times;
Example: After receiving 2 ringing signals, start the host to work remote control
Password[36][2]
Operating method:
Notes: The host remote control closed, when ringing times is set to 0
LCD display:
18.Password Change Setting
1. Change User Password(Default:1234)
User password is the key to enter the host operating system when start
Disarm or Remote Control.
Press
firstly, then input 4- digit password by the keypad,input instruction[38],
and then input the 4- digit new password, finally press
to confirm. The main
unit will make a long beep and you will hear a voice prompt “setting completed”.
Operating:
Password[38][XXXX]
XXXX indicates:the new 4-digit password
Example: change the system password to 1012;
Operating:
LCD display:
Password[38][1012]
2. Change Administrator Password(Default:6666)
Administrator password is the key to enter the host system when need
function setting.
Press
should be entered.
Example: Open the keypad lock.
Operating:
Password[40][1]
LCD display:
firstly, then input 4- digit password by the keypad,input instruction
[39], and then input the 4- digit new password, and then press
to confirm.
The host emits will make a long beep and you will hear a voice prompt “setting
completed”.
Operating:
Password[39][XXXX]
XXXX indicates: the new 4-digit password
Example: change the system password to 2846
Operating:
Password [39][2846]
LCD display:
20.Turning Host Timed Arm/Disarm on/off
Setting(Default: Closed)
Press
firstly, then input 4- digit password by the keypad,input instruction
[41], then choose on/off timed Arm or Disarm function key[1/0], finally press
to confirm, The host makes a long beep. You will hear a voice prompt “setting
completed”.
Note: The user password and the Administrator password cannot be the same.
Operating:
Password [41][X]
X=“0” indicates: close all timed Arm/Disarm function.
X=“1” indicates: Open all timed Arm/Disarm function..
Example: Indicates: Open all timed Arm/Disarm function
19.Keypad lock setting(Default: Closed)
Keypad lock could ensure the host password can’t be changed maliciously.
Press
firstly, then input 4- digit password by the keypad,input instruction
[40], then input [0~1], finally press
to confirmed. The host makes a long
beep. You will hear a voice prompt “setting completed”.
Operating:
Password[40][X]
X=“0” indicates: Keypad lock is closed. Arm/Disarm, password
don’t need to be entered
X=“1” indicates: Keypad lock is open. Arm/Disarm, password
Operating:
LCD display:
Password[41][1]
21. Host Timed Arm /Disarm Setting
Timed arm or disarm is convenient to arm or disarm at the necessary
time.
Press
firstly, then input 4- digit password by the keypad,input instruction [42],
and then input disarming time [AABB], and then input arming time [XXYY],
finally press
to confirm. The host makes a long beep.
prompt “setting completed”.
Operating:
You will hear a voice
Password [42][AABB][XXYY]
“AABB” indicates: disarming time—hour and minute
“XXYY” indicates: arming time—hour and minute
Example: set disarming is 8:20 and arming time is 20:30.
Operating:
Password [42][0820][2030]
LCD display:
23. Host Historical Records Inquires Setting
Press
firstly, then input 4- digit password by the keypad,input instruction [44],
then press
to confirm. The host makes a long beep. You will hear a voice
prompt “setting completed”. Press “2” to page up and press “8” to page down
Operating:
LCD display:
Password [44]
24.Host Historical Records Inquires Deleting Setting
Press
22.Host Reset Setting
All telephone number will be deleted automatically when main host reset.
Press
firstly, then input 4- digit password by the keypad,input instruction
[43], then press
to confirm. The host makes a long beep. You will hear a
voice prompt “setting completed”. (Will not delete the remote control and
accessories)
Password [43]
Operating:
LCD display:
firstly, then input 4- digit password by the keypad,input instruction
[45], then press
to confirm. The host makes a long beep.
voice prompt “setting completed”.
Operating:
LCD display:
Password [45]
You will hear a
25.Arm/ Disarm SMS alert Setting(Default: Will not send)
To ensure safety, alarm panel will (or not) send a SMS to user when arm/
Example: set the time as 17:30, June, 12th, 2012
Operating:
Password [48][12][06][12][17][30]
LCD display:
disarm
Press
firstly, then input 4- digit password by the keypad,input instruction
[46]. Then choose whether alarm panel need to send a SMS to user [0/1], finally
press
to confirm. The host makes a long beep. You will hear a voice prompt
“setting completed”. Factory value is [0]: alarm panel will not send SMS to
user.
Operating:
27.SMS Phone Number Setting
Password [46][0/1]
“1” indicates: alarm panel will send SMS to user.
“0” indicates: alarm panel will not send SMS to user.
Press
firstly, then input 4- digit password by the keypad,input instruction
[49~50], then input phone number; finally press to confirm. The host makes a
long beep, You will hear a voice prompt: setting completed.
LCD display:
Note: 49 for the first group of SMS phone number, 50 for the second group of
SMS phone number.
Operating:
Password [49][YY…YY]
YY…YY Indicates: phone number
Example: set 13911112245 to be first group alarm phone number
Password[49][13911112245]
Operating:
LCD display:
26. System Clock Setting
Press
firstly, then input 4- digit password by the keypad,input instruction
[48], then input the last 2 digits [AA] of the present year, the two digits [BB] of the
month, the two digits [CC] of the date. The two digits [DD] of the hour (24-hour
system), the two digits [EE] of the minute, and finally enter
will hear a long beep and a voice prompt “setting completed”.
Operating:
to confirm. You
Password[48][AA][BB][CC][DD][EE]
“AA” indicates: the last 2 digits of the present year
“BB” indicates: the 2 digits of the present month
28.SMS Phone Number Delete Setting
“CC” indicates: the 2 digits of the present date
Press
“DD” indicates: the 2 digits of the present hour
[49~50], then press
to confirm. The host makes a long beep, You will hear a
voice prompt: setting completed.
“EE” indicates: the 2 digits of the present second
firstly, then input 4- digit password by the keypad,input instruction
Operating:
Password[XX]
XX indicates: address code [49] ~ [50] of 1-2 group SMS phone number
30.Alarm call Number Delete Setting
Example: Delete the first group of SMS phone number.
Press
Operating: [49]
LCD display:
[51] ~ [56], then press
to confirm. The host makes a long beep, You will
hear a voice prompt: setting completed.
firstly, then input 4- digit password by the keypad,input instruction
Operating:
Password[XX]
XX indicates: address code [51] ~ [56] of 1-6 group alarm phone number
Example: Delete the 1 group of alarm phone number.
Operating:
Password [51]
LCD display:
29.Alarm call Number Setting
Press
firstly, then input 4- digit password by the keypad,input instruction
[51] ~ [56], then input phone number, finally press
to confirm. The host
makes a long beep, You will hear a voice prompt: setting completed.
31.Defense Zone name Setting
Operating:
Password[XX][YY…YY]
XX indicates: address code [51] ~ [56] of 1-6 group alarm phone number
Press
YY…YY indicates: phone numbers
Example: set 13811110751 to be first group alarm phone number
Operating:
Password[51][13811110751]
LCD display:
firstly, then input 4- digit password by the keypad,input instruction [60],
choose the corresponding defense zone code [02] ~ [99] , and then input [1 ~ 8] defense
zone alarm type, finally add
Operating:
key to confirm. Voice prompt: setting completed.
Password 【60】【XX】【 A 】
XX indicates defense zone code: [02] ~ [99], matching 02 to 99 defense zones
correspondingly
A Form alarm type: [1] SOS Alarm, [2] fire alarm, [3] gas leak alarm,
[4] Door lock alarm, [5] hall alarm, [6] window alarm,
[7] Balcony alarm, [8] perimeter alarm.
Example: 10-defense zone fire alarm operation
Operating:
Password【60】【 10 】【 2 】
32. Host GSM Signal Checking
Press
firstly, then input 4- digit password by the keypad,input instruction
[62] and then press
to confirm. The host makes a long beep, you will hear a
voice prompt: “setting completed”. GSM signal value displays.
Operating:
LCD display:
Password [62]
3) Home Arm:
Press [
4) SOS:
Press [
]
]
3. Away Arm
It means to guard all around your house while everyone is going out; all the det
ectors of the host are always working; when the detector is triggered by
detecting source(anti-theft, fire prevention,gas leak, etc), the alarm system will
sound the alarm.
[Operation Instructions]
Press [Out Arm
1. Main Host Status
and totally 100 beeps. The [Out Arm
System status: There are 4 status types as follows:
1) Arm: Defense zone 02-99 will alarm when detectors are triggered
] button on keypad, system will make a beep per second
] indicator will be on without flashing. It
means Out Arm is set successfully.
Operating: press [Out Arm
] of remote controller
2) Home Arm: In arm status, the defense zone which is set as [Home arm],
The Host Operating: [Out Arm
[user password] +
LCD display:
] (keypad lock is closed or [Out Arm
]+
(keypad lock is open)
when detectors are triggered.
3) Disarm: Defense zone 02-99 will not alarm when detector triggered (except
24 hours defense zone).
4) System setup status: In this status, all defense zones will not alarm when
4. Home Arm
detectors are triggered.
2. Remote Controller Operation
It means, for the safety, while somebody is at home, you need to enable
the peripheral: door, window, balcony and boundary detectors of the alarm
User can use remote controller to set system as Out Arm, Home Arm,
system while prevent from triggering the indoor detectors, which may cause
Emergency Alarm, Real-time Disarm and etc.
improper warning; then, you shall select Home Arm, let just part of the detectors
1) Out Arm:
Press [
]
work and disable the other parts.
2) Disarm:
Press [
]
Alarm host operation: Press
Remote Control Operation: Just press [
number automatically. The system will call each preset numbers for 3 times in
].
LCD display:
order.
If you answer the all, you will hear the pre-record voice message . You can set
system via your telephone or mobile phone keypad.
If you hang-up directly without answering the call, system will call each preset
number for 3 times circularly.
Press [*]: listen voice recording message
Press [1]: The host stops alarming and to Arm; it stops calling users.
5. Disarm
Press [2]: The host stops alarming and to Disarm; it stops calling users.
It means to stop the alarm when the host sounds the alarm or makes the alarm
Press [3]: The host closes Siren and monitors the scene for 30 seconds, for
system in the state of non-warning. After disarming, even if you trigger the
continuous monitoring, press [3] again to monitor the abnormal
detector, the host would not sound alarm (excluding 24- hour defense areas).
sounds or a burglar intrusion for another 30 seconds.
Press [4]: start talkback 30s.
If keypad lock is closed, press
on keypad directly to disarm. If keypad lock is
Press [6]: Turn on the relay NO.1. (Press 6 again, turn it off).
Press [7]: Turn on the relay NO.2. (Press 7 again, turn it off).
open, press
, and follow voice prompt enter [user password, finally press
to
confirm. Disarming operation is completed.
Press [9]: Turn on the relay NO.4. (Press 9 again, turn it off).
Remote Control Operation: Press [
].
The Host Operating:
].
Press [
Press [8]: Turn on the relay NO.3. (Press 8 again, turn it off).
LCD display:
Press [#]: Stop calling users.
7. Remote control by making call to host
The telephone (mobile) is connected to alarm host number, and after ringing
times setting, the telephone receiver prompts computer-generated voice:
“Please enter password”. The password is entered via telephone (mobile). For
wrong password, the host gives prompt: “wrong password, please enter
password again”. For correct password, the telephone receiver prompts “press
① to arm, press ② to disarm, press ③ to monitor, press 4 to talk ”. And after
it is accessed, phone button could be used for remote control.
6.
Answer Alarm Call
When the host sounds alarm, Siren releases voice prompt at once: first, would
send out SMS, telling user which defense zone has alarm, and then it will dial
the preset numbers. If no one answers the call, the system will call the next user
Press [1]: the host enters Arm state and voice prompts “Armed”.
Press [2]: the host enters Disarm state and voice prompts “Disarmed”.
Press [3]: the host enters monitoring state for 30 seconds and press [3] for 30
seconds delay repeatedly in case of continuous monitoring.
Press [6]: Turn on the relay NO.1. (Press 6 again, turn it off).
Press [7]: Turn on the relay NO.2. (Press 7 again, turn it off).
Press [8]: Turn on the relay NO.3. (Press 8 again, turn it off).
Press [9]: Turn on the relay NO.4. (Press 9 again, turn it off).
Press [*] : Play voice recording message.
9. SOS
Some special cases occur in the family: sudden illness for the elderly or children
results in first aid; in case of sudden fire, help is needed; in case of housebreaking,
the alarm is required; So please just press the host keypad “Emergency Alarm
” ,remote controller key [
alarming
]. Alarm system will immediately sound loudly and
Remote operation: press remote control [a ].
Keypad operation: press alarm host keypad
.
10. Alarm host used as hand-free phone
This alarm system has dial-up function and could be used as hand-free phone.
In disarming status,input phone number [13800138000], then press
, main
host makes a long beep, then phone call will go out ,after Call completed,
press
again to hang up phone.
11. Maintenance
1. System detection
Although the alarm system is used every day, it still needs regular care and
maintenance and detection to ensure that the alarm system will be stable,
reliable and safe. Normally the host needs a thorough inspection every 3
months and the detectors need to be checked once a month, at least once
every 3 months in case of no good conditions.
Console detection:
Sensor detection:
Technical Parameter
Adaptor power:
DC12V
Static consumption:
≤55mA
Alarm current:
≤450mA
Output current:
DC12V
Wireless frequency:
1). manually trigger the detector to check whether it sounds normal alarm.
1000mA
2). Check batteries of all detectors to make sure whether it is under-voltage.
3). Check whether wireless detector is communicated with the host during
emission testing
2. Notices
150mA
Alarm equipment, for explosion-proof design, shall not directly be used in
315MHz/433MHz
hazardous location with Grade I, II and III (flammable and explosive places),
900/1800/1900/850Mhz
otherwise it is very dangerous.
110dB
Do not dismantle, repair and modify products privately, or accidents and
Backup battery:
NI-MH AAA*6 7.2V DC
failures may be caused.
Temperature:
-20℃ ~ +55℃
GSM
Siren volume:
Do not drop the product on the ground or hard objects to avoid strong
Humidity:
40% ~ 80%RH
Encoded mode:
2262 IC / 4.7MΩ
impact for failure and damage.
Without permit and consent from relevant department, do not directly set
"110", "119" or alarm phone number of police station as alarm phone
number of the host.
1). whether the host normally performs Arm or Disarm.
Defense zone
Arm
Home
Type
Siren
1 defense zone
effective
effective
24H
Yes
02-99 defense zone
effective
effective
Real-time
Yes
effective
effective
24H
Yes
effective
effective
Real-time
Yes
SOS
Wired defense zone
Administrator
6666
Remote control
On
password
User password
1234
Siren
Off
Siren sound time
According setting
Home appliance
Optional
[Technical Parameters]
1. Table one
time
2). whether the host normally dials up the telephone numbers.
3). whether the detector signal is received or backup battery works.
2.
Table two
3. Administrator password system setup command table
Data
19
Keypad Lock Setting
40
X
20
Host Timing Setting
41
X
X=1 open,
X=0 closed
0
No
0
21
YYYY
time
X
X=#
42
Setting
22
XXXX= arm time YYYY= disarm
Host Reset
43
1
44
X
X=#
45
X
X=#
X
X=#
23
X
X=02~99
24
X
X=02~99
25
X
X=#
26
XY
X=02~99,Y=0~3
47
XY
X=81~88,Y=0~3
XXXX
XXXXXXXX=8 digit
XXXX
wireless equipment coding
XXXX= 4 digit user number
All Wireless Detectors
5
Deleting
46
X
X=0 don’t
7
XXX
XXX=year, month,day,
8
YY
YY= hour, minute
X
X= SMS number
49~
Setting
50
Host Alarm Phone
51~
28
56
Host Center Call Number
57~
29
X=alarm number
58
GSM Signal Checking
62
Wireless Equipment
27
Coding Setting
9
User ID Setting
28
XXXX
10
Siren Prompt Setting
31
X
X=1 siren prompt open,
11
Siren Ring Time Setting
32
X
X=00~15 minutes
3 minutes
X= Call number of Receiving
12
Arm Time Delayed
33
X
X=00~99 seconds
0 second
Center
13
Alarm Time delayed
34
X
X=00~99 seconds
0 seconds
35
X
X=00~09 times
9 times
X=0~9 times
9 times
X
Setting
Wired Alarm Type Setting
X=0 siren prompt closed
X
Number Setting
Setting
Center
48
27
Wireless Alarm Type
6
inform Receiving
Center
30
22
Deleting
X=1 inform Receiving Center
Host SMS Number
X=#
Single Wireless Detector
Arm/ Disarm Upload to
Clock Setting
Coding of Detector
4
Deleting
26
X
Remote Controller
2
3
Host Historical Records
25
21
Controller
Inquires
24
Default
Deleting
Historical Records
23
Factory
Remark
(XY)
X=0 close time setting function
XXXX
Add
Coding of Remote
X=1 open time setting function
Host Arm or Disarm
Setting item
X
X=#
Telephone Dial-up Cycle
14
Times
15
Remote Call Ring Times
36
X
16
Artificial Recording
37
X
X=#, play automatically after
recording
17
Change User Password
38
XXXX
XXXX= 4 digit
1234
39
XXXX
XXXX= 4 digit
6666
Change Administrator
18
Password
Download PDF